{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"INTERCONNECTION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#36"],"comment":"Inter-regional flow information common to or aggregated for regulated (i.e. not MNSP) Interconnectors spanning the From-Region and To-Region - NB only the physical run is calculated'","primary_keys":["FROM_REGIONID","INTERVENTION","RUNNO","SETTLEMENTDATE","TO_REGIONID"],"columns":{"FROM_REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Nominated RegionID from which the energy flows","examples":["NSW1","TAS1","VIC1"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention case or not","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TO_REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated RegionID to which the energy flows","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP","examples":["20260831241","20260901202"],"is_integer":true,"num_int_bits":128},"FROM_REGION_MW_LOSSES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Losses across the Interconnection attributable to the nominal From Region","examples":["-0.007522","0.006059","0","74.27363"],"is_float":true},"IRLF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Inter-Regional Loss Factor. Calculated based on the MWFLOW and the nominal From and To Region losses.","examples":["0.66667","0","1.5"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"METEREDMWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Summed Metered MW flow of the parallel regulated Interconnectors","examples":["-3.300049","5.999847","0","224"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Summed MW flow of the parallel regulated Interconnectors","examples":["-0.59655","2.68798","0","162"],"is_float":true},"TO_REGION_MW_LOSSES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Losses across the Interconnection attributable to the nominal To Region","examples":["-0.004418","0.004544","0","83.457116"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_INTERCONNECTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1054799,"decompressed_size_all_time":229130890},"visibility":"Public","trigger":"Every 5 minutes"}