{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"REGION_FREQ_MEASURE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#97"],"comment":"This report delivers the curated 4 second frequency deviation and frequency measure data for each region","primary_keys":["INTERVAL_DATETIME","MEASUREMENT_DATETIME","REGIONID","VERSIONNO"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MEASUREMENT_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the SCADA data (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:00:04"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID of the frequency deviation / frequency measure","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"FM_ALIGNMENT_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Boolean","mandatory":false,"comment":"Alignment Flag (4 second frequency deviation is aligned with 4 second frequency measure for that region) Supported values are: 0 = Misaligned 1 = Aligned","examples":["0","1"],"is_boolean":true},"FREQ_DEVIATION_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Deviation (4 second frequency deviation in Hz for that region)","examples":["-0.001","0.001","0","0.065"],"is_float":true},"FREQ_MEASURE_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated 4 second Frequency Measure for that region from FPP database","examples":["-0.00003285","0.00010003","-0.02822295","0.04382655"],"is_float":true},"HZ_QUALITY_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"Frequency Quality (4 second frequency deviation quality for that region) Supported values are: 0 = Bad Quality 1 = Good Quality 2 = Suspect Quality -1 = Value not used as input in the FPP calculation (generally used to indicate when SCADA data was late arriving after the FPP calculation commenced)","examples":["1"],"is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_REGION_FREQ_MEASURE%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":32480406,"decompressed_size_all_time":72525535790},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"}