{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENCONSETTRK","REPORT_SUB_TYPE":"NULL","VERSION":1},{"REPORT_NAME":"GENCONSETTRK","REPORT_SUB_TYPE":"NULL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#36"],"comment":"GENCONSETTRK assists in determining the correct version of a generic constraint set that has been invoked in GENCONSETINVOKE.","description":"GENCONSETTRK data is public to all participants.\n\nSource\n\nAd hoc updates occur to GENCONSETTRK.","primary_keys":["EFFECTIVEDATE","GENCONSETID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date this record becomes effective","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONSETID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique ID for the Constraint Set","examples":["#BARKIPS1_DE","#DRYCGT1_DE","#DRYCGT2_DE","#MCINTYR1_E","#NSW1-QLD1_RAMP_I","#QPS5_DE","#R036713_RAMP","#R036714_RAMP","#R036715_RAMP","#R036716_RAMP","#R036717_RAMP","#R036718_RAMP","#R036719_RAMP","#R036720_RAMP","#R036721_RAMP","#R036722_RAMP","#R036723_RAMP","#R036724_RAMP","#R036725_RAMP","#R036726_RAMP","#R036727_RAMP","#R036728_RAMP","#R036729_RAMP","#R036730_RAMP","#R036731_RAMP","#R036732_RAMP","#R036733_RAMP","#R036734_RAMP","#R036735_RAMP","#R036736_RAMP","#R036737_RAMP","#R036738_RAMP","#R036739_RAMP","#R036740_RAMP","#R036741_RAMP","#R036742_RAMP","#R036743_RAMP","#R036744_RAMP","#R036745_RAMP","#R036746_RAMP","#R036747_RAMP","#R036748_RAMP","#R036749_RAMP","#R036750_RAMP","#R036751_RAMP","#R036752_RAMP","#R036753_RAMP","#R036754_RAMP","#R036755_RAMP","#R036756_RAMP","#R036757_RAMP","#R036758_RAMP","#R036759_RAMP","#R036760_RAMP","#R036761_RAMP","#R036762_RAMP","#R036763_RAMP","#R036764_RAMP","#R036765_RAMP","#R036766_RAMP","#R036767_RAMP","#R036768_RAMP","#R036769_RAMP","#R036770_RAMP","#R036771_RAMP","#R036772_RAMP","#R036773_RAMP","#R036774_RAMP","#R036775_RAMP","#R036776_RAMP","#R036777_RAMP","#R036778_RAMP","#R036779_RAMP","#R036780_RAMP","#R036781_RAMP","#R036782_RAMP","#R036783_RAMP","#R036784_RAMP","#R036785_RAMP","#R036786_RAMP","#R036787_RAMP","#R036788_RAMP","#R036789_RAMP","#R036790_RAMP","#R036791_RAMP","#R036792_RAMP","#R036793_RAMP","#R036794_RAMP","#R036795_RAMP","#R036796_RAMP","#R036797_RAMP","#R036798_RAMP","#R036799_RAMP","#R036800_RAMP","#R036801_RAMP","#R036802_RAMP","#R036803_RAMP","#R036804_RAMP","#R036805_RAMP","#R036806_RAMP","#R036807_RAMP","#R036808_RAMP","#R036809_RAMP","#R036810_RAMP","#R036811_RAMP","#R036812_RAMP","#R036813_RAMP","#R036814_RAMP","#R036815_RAMP","#R036816_RAMP","#R036817_RAMP","#R036818_RAMP","#R036819_RAMP","#R036820_RAMP","#R036821_RAMP","#R036822_RAMP","#R036823_RAMP","#R036824_RAMP","#R036825_RAMP","#R036826_RAMP","#R036827_RAMP","#R036828_RAMP","#R036829_RAMP","#R036830_RAMP","#R036831_RAMP","#R036832_RAMP","#R036833_RAMP","#R036834_RAMP","#R036835_RAMP","#R036836_RAMP","#R036837_RAMP","#R036838_RAMP","#R036839_RAMP","#R036840_RAMP","#R036841_RAMP","#R036842_RAMP","#R036843_RAMP","#R036844_RAMP","#R036845_RAMP","#R036846_RAMP","#R036847_RAMP","#R036848_RAMP","#R036849_RAMP","#R036850_RAMP","#R036851_RAMP","#R036852_RAMP","#R036853_RAMP","#R036854_RAMP","#R036855_RAMP","#R036856_RAMP","#R036857_RAMP","#R036858_RAMP","#R036859_RAMP","#R036860_RAMP","#R036861_RAMP","#R036862_RAMP","#R036863_RAMP","#R036864_RAMP","#R036865_RAMP","#R036866_RAMP","#R036867_RAMP","#R036868_RAMP","#R036869_RAMP","#R036870_RAMP","#R036871_RAMP","#R036872_RAMP","#R036873_RAMP","#R036874_RAMP","#R036875_RAMP","#R036876_RAMP","#R036877_RAMP","#R036878_RAMP","#R036879_RAMP","#R036880_RAMP","#R036881_RAMP","#R036883_RAMP","#R036884_RAMP","#R036885_RAMP","#R036886_RAMP","#R036887_RAMP","#R036888_RAMP","#R036889_RAMP","#R036890_RAMP","#R036891_RAMP","#R036892_RAMP","#R036893_RAMP","#R036894_RAMP","#R036895_RAMP","#R036896_RAMP","#R036897_RAMP","#R036898_RAMP","#R036899_RAMP","#R036900_RAMP","#R036901_RAMP","#R036902_RAMP","#R036903_RAMP","#R036904_RAMP","#R036905_RAMP","#R036906_RAMP","#R036907_RAMP","#R036908_RAMP","#R036909_RAMP","#R036910_RAMP","#R036911_RAMP","#R036912_RAMP","#R036913_RAMP","#R036914_RAMP","#R036915_RAMP","#R036916_RAMP","#R036917_RAMP","#R036918_RAMP","#R036919_RAMP","#R036920_RAMP","#R036921_RAMP","#R036922_RAMP","#R036923_RAMP","#R036924_RAMP","#R036925_RAMP","#R036926_RAMP","#R036927_RAMP","#R036928_RAMP","#R036929_RAMP","#R036930_RAMP","#R036931_RAMP","#R036932_RAMP","#R036933_RAMP","#R036934_RAMP","#R036935_RAMP","#R036936_RAMP","#R036937_RAMP","#R036938_RAMP","#R036939_RAMP","#R036940_RAMP","#R036941_RAMP","#R036942_RAMP","#R036943_RAMP","#R036944_RAMP","#R036945_RAMP","#R036946_RAMP","#R036947_RAMP","#R036948_RAMP","#R036949_RAMP","#R036950_RAMP","#R036951_RAMP","#R036952_RAMP","#R036953_RAMP","#R036954_RAMP","#R036955_RAMP","#R036956_RAMP","#R036957_RAMP","#R036958_RAMP","#R036959_RAMP","#R036960_RAMP","#R036961_RAMP","#R036962_RAMP","#R036963_RAMP","#R036964_RAMP","#R036965_RAMP","#R036966_RAMP","#R036967_RAMP","#R036968_RAMP","#R036969_RAMP","#R036970_RAMP","#R036971_RAMP","#R036972_RAMP","#R036973_RAMP","#R036974_RAMP","#R036975_RAMP","#R036976_RAMP","#R036977_RAMP","#R036978_RAMP","#R036979_RAMP","#R036980_RAMP","#R036981_RAMP","#R036982_RAMP","#R036983_RAMP","#R036984_RAMP","#R036985_RAMP","#R036986_RAMP","#R036987_RAMP","#R036988_RAMP","#R036989_RAMP","#R036990_RAMP","#R036991_RAMP","#R036992_RAMP","#R036993_RAMP","#R036994_RAMP","#R036995_RAMP","#R036996_RAMP","#R036997_RAMP","#R036998_RAMP","#R036999_RAMP","#R037000_RAMP","#R037001_RAMP","#R037002_RAMP","#R037003_RAMP","#R037004_RAMP","#R037005_RAMP","#R037006_RAMP","#R037007_RAMP","#R037008_RAMP","#R037009_RAMP","#R037010_RAMP","#R037011_RAMP","#R037012_RAMP","#R037013_RAMP","#R037014_RAMP","#R037015_RAMP","#R037017_RAMP","#R037018_RAMP","#R037019_RAMP","#R037020_RAMP","#R037021_RAMP","#R037022_RAMP","#R037023_RAMP","#R037024_RAMP","#R037025_RAMP","#R037026_RAMP","#R037027_RAMP","#R037028_RAMP","#R037029_RAMP","#R037030_RAMP","#R037031_RAMP","#R037032_RAMP","#R037033_RAMP","#R037034_RAMP","#R037035_RAMP","#R037036_RAMP","#R037037_RAMP","#R037038_RAMP","#R037039_RAMP","#R037040_RAMP","#R037041_RAMP","#R037042_RAMP","#R037043_RAMP","#R037044_RAMP","#R037045_RAMP","#R037046_RAMP","#R037047_RAMP","#R037048_RAMP","#R037049_RAMP","#R037050_RAMP","#R037051_RAMP","#R037052_RAMP","#R037053_RAMP","#R037054_RAMP","#R037055_RAMP","#R037056_RAMP","#R037057_RAMP","#R037058_RAMP","#R037059_RAMP","#R037060_RAMP","#R037061_RAMP","#R037062_RAMP","#R037063_RAMP","#R037064_RAMP","#R037065_RAMP","#R037066_RAMP","#R037067_RAMP","#R037068_RAMP","#R037069_RAMP","#R037070_RAMP","#R037071_RAMP","#R037072_RAMP","#R037073_RAMP","#R037074_RAMP","#R037075_RAMP","#R037076_RAMP","#R037077_RAMP","#R037078_RAMP","#R037079_RAMP","#R037080_RAMP","#R037081_RAMP","#R037082_RAMP","#R037083_RAMP","#R037084_RAMP","#R037085_RAMP","#R037086_RAMP","#R037087_RAMP","#R037088_RAMP","#R037089_RAMP","#R037090_RAMP","#R037091_RAMP","#SSE_BARKIPS1_40","#SSE_PPCCGT_20","#SSE_PPCCGT_21","#SSE_PPCCGT_22","#SSE_PPCCGT_23","#SSE_PPCCGT_24","#SSE_PPCCGT_25","#SSE_PPCCGT_26","#SSE_PPCCGT_27","#SSE_PPCCGT_28","#SSE_PPCCGT_29","#SSE_PPCCGT_30","#SSE_PPCCGT_31","#SSE_PPCCGT_32","#SSE_PPCCGT_33","#SSE_PPCCGT_34","#SSE_PPCCGT_35","#SSE_PPCCGT_36","#SSE_PPCCGT_37","#SSE_PPCCGT_38","#SSE_PPCCGT_39","#TORRB4_DE","#TORRB4_E","#VIC1_E_20260915","#VIC1_E_20260916","A-N_BHB1_ZERO_E","A-N_BHB1_ZERO_G_E","A-N_CABESA1_ZERO_E","A-N_CABESA1_ZERO_G_E","A-N_CABESA2_ZERO_E","A-N_CABESA2_ZERO_G_E","A-N_ERB01_ZERO_E","A-N_ERB01_ZERO_G_E","A-N_ERB02_ZERO_E","A-N_ERB02_ZERO_G_E","A-N_LDBESS1_ZERO_E","A-N_LDBESS1_ZERO_G_E","A-N_LIMBES1_ZERO_E","A-N_LIMBES1_ZERO_G_E","A-N_MUGALB1_ZERO_E","A-N_MUGALB1_ZERO_G_E","A-N_MUGALB2_ZERO_E","A-N_MUGALB2_ZERO_G_E","A-N_NESBES1_ZERO_E","A-N_NESBES1_ZERO_G_E","A-N_NESBES2_ZERO_E","A-N_NESBES2_ZERO_G_E","A-N_ORABES1_ZERO_E","A-N_ORABES1_ZERO_G_E","A-N_QPSFB2_ZERO_E","A-N_QPSFB2_ZERO_G_E","A-N_WILBES1_ZERO_E","A-N_WILBES1_ZERO_G_E","A-Q_BLUEGB1_ZERO_E","A-Q_BLUEGB1_ZERO_G_E","A-Q_BRDBES1_ZERO_E","A-Q_BRDBES1_ZERO_G_E","A-Q_SNB02_ZERO_E","A-Q_SNB02_ZERO_G_E","A-Q_STABES1_ZERO_E","A-Q_STABES1_ZERO_G_E","A-Q_WOOLES1_ZERO_E","A-Q_WOOLES1_ZERO_G_E","A-S_BUNGAM1_ZERO_E","A-S_BUNGAM1_ZERO_G_E","A-S_CGBESS1_ZERO_E","A-S_CGBESS1_ZERO_G_E","A-S_LGAPBS1_ZERO_E","A-S_LGAPBS1_ZERO_G_E","A-S_MANUMB1_ZERO_E","A-S_MANUMB1_ZERO_G_E","A-S_SMFBES1_ZERO_E","A-S_SMFBES1_ZERO_G_E","A-S_SMFBES2_ZERO_E","A-S_SMFBES2_ZERO_G_E","A-S_TB3B1_ZERO_E","A-S_TB3B1_ZERO_G_E","A-S_TEMPB1_ZERO_E","A-S_TEMPB1_ZERO_G_E","A-V_HREBES1_ZERO_E","A-V_HREBES1_ZERO_G_E","A-V_MLB01_ZERO_E","A-V_MLB01_ZERO_G_E","A-V_MREHA1_ZERO_E","A-V_MREHA1_ZERO_G_E","A-V_MREHA2_ZERO_E","A-V_MREHA2_ZERO_G_E","A-V_MREHA3_ZERO_E","A-V_MREHA3_ZERO_G_E","A-V_MRNBES1_ZERO_E","A-V_MRNBES1_ZERO_G_E","A-V_PLBESS1_ZERO_E","A-V_PLBESS1_ZERO_G_E","A-V_TRGBES1_ZERO_E","A-V_TRGBES1_ZERO_G_E","CA_AUTO","CA_BRIS_59B1E7AD","CA_BRIS_59B1E9F4","CA_BRIS_59B1EA1C","CA_BRIS_59CD80D1","CA_BRIS_59CEBC99","CA_BRIS_59CEC97F","CA_BRIS_59CEE304","CA_SYDS_59A889E5","CA_SYDS_59B363DF","CA_SYDS_59C65DD6","CA_SYDS_59C65E31","I*DATASNAP","I-JNWO_63","I-JNWO_X5","I-NS_050","I-NS_100","I-NS_150","I-NS_200","I-NS_250","I-NS_300","I-NS_350","I-NS_400","I-NS_450","I-NS_500","I-NS_550","I-NS_600","I-NS_650","I-NS_700","I-NS_750","I-NS_800","I-PEC_ZERO","I-SN_050","I-SN_100","I-SN_150","I-SN_200","I-SN_250","I-SN_300","I-SN_350","I-SN_400","I-SN_450","I-SN_500","I-SN_550","I-SN_600","I-SN_650","I-SN_700","I-SN_750","I-SN_800","I-SVS_000","I-SVS_020","I-SVS_040","I-SVS_060","I-SVS_080","I-SVS_100","I-SVS_120","I-SVS_140","I-SVS_160","I-SVS_180","I-SVS_200","I-SVS_220","I-SVS_240","I-SVS_260","I-SVS_270","I-SVS_280","I-SVS_300","I-SVS_340","I-SVS_350","I-SVS_400","I-SVS_420","I-SVS_450","I-SVS_470","I-SVS_500","I-SVS_520","I-SVS_540","I-SVS_550","I-SVS_560","I-SVS_580","I-SVS_600","I-SVS_620","I-SVS_640","I-SVS_650","I-SVS_660","I-SVS_680","I-SVS_700","I-SVS_720","I-SVS_740","I-SVS_750","I-SVS_760","I-SVS_780","I-SVS_800","I-SVS_820","I-SVS_840","I-SVS_850","I-SVS_870","I-SV_500","I-SV_550","I-TV_CLPS","I-VSS_000","I-VSS_020","I-VSS_040","I-VSS_060","I-VSS_080","I-VSS_100","I-VSS_120","I-VSS_140","I-VSS_160","I-VSS_180","I-VSS_200","I-VSS_220","I-VSS_240","I-VSS_260","I-VSS_280","I-VSS_300","I-VSS_320","I-VSS_340","I-VSS_360","I-VSS_380","I-VSS_400","I-VSS_420","I-VSS_440","I-VSS_460","I-VSS_480","I-VSS_500","I-VSS_550","I-VSS_600","I-VSS_620","I-VSS_650","I-VSS_700","I-VSS_700M","I-VSS_720","I-VSS_740","I-VSS_750","I-VSS_760","I-VSS_780","I-VSS_800","I-VSS_820","I-VSS_840","I-VSS_850","I-VSS_870","I-VSS_ZERO","I-VS_500","I-VS_570","I-VS_600","I-VS_650","I-X_BDBU_BUDW","L-PEC_NIL","L-PEC_NIL_NFB","L-PEC_X_6C_6G_6H","L-PEC_X_6C_6G_6H_NFB","N-ARTW_86","N-BADP","N-BALM_X8","N-CLCWG_63","N-CLCWG_X5","N-DPTX1-2","N-DPWG_63","N-JNWG_RADIAL","N-JNWL_63","N-JNWL_X5","N-LTWG_63","N-LTWG_X5","N-NIL","N-SOWL_79","N-STUBSF_ZERO","N-STUBSF_ZERO_INV","N-UGWL_7J","N-WAGGA_330_BUSA","N-WGWA_63","N-WGWA_63_X5","N-WGWA_X5","N-WG_BUR_IBR_0","N-WG_BUR_IBR_0100","N-WG_BUR_IBR_0200","N-WG_BUR_IBR_0300","N-WG_BUR_IBR_0400","N-WG_BUR_IBR_0500","N-WG_BUR_IBR_0600","N-WG_BUR_IBR_0700","N-WG_BUR_IBR_0800","N-WG_BUR_IBR_0900","N-WG_BUR_IBR_1000","N-WG_BUR_IBR_1100","N-WG_BUR_IBR_1200","N-WG_BUR_IBR_1300","N-WG_BUR_IBR_1400","N-WG_BUR_IBR_1500","N-WG_BUR_IBR_1600","N-WG_BUR_IBR_1700","N-WG_BUR_IBR_1800","N-WG_BUR_IBR_1900","N-WG_BUR_IBR_2000","N-WG_BUR_IBR_2100","N-WG_BUR_IBR_2200","N-WG_BUR_IBR_2300","N-WG_BUR_IBR_2400","N-WG_BUR_IBR_2500","N-WG_BUR_IBR_2600","N-WG_BUR_IBR_2700","N-WG_BUR_IBR_2800","N-WG_BUR_IBR_2900","N-WG_BUR_IBR_3000","N-WG_BUR_IBR_3100","N-WG_BUR_IBR_3200","N-WG_BUR_IBR_3300","N-WG_BUR_IBR_3400","N-WG_BUR_IBR_3500","N-WG_BUR_IBR_3600","N-WG_BUR_IBR_3700","N-WG_BUR_IBR_3800","N-WOLLARSF1_ZERO_INV","N-X_6C_6G_6H","N-X_94T+94M","N-X_BABU_BADP","N-X_DPTX1+2","N-X_TWNR_MORNR","NC-S_TB3B1","NC-V_WOORB1","NRM_NIL_ALL","Q-BCBS_820","Q-BCCP_812","Q-BCNE_821","Q-BCRG_811","Q-BCST","Q-BSNE","Q-BSNE_834","Q-BS_275BUS_CB","Q-CLST","Q-CLWU","Q-CL_275BUS_CB","Q-CN1000","Q-CPWU_818","Q-H13RS_SVC","Q-HAURS","Q-LCCP_8859","Q-NESTM","Q-NE_275BUS_CB","Q-RGLC_8875","Q-RS_275BUS_CB","Q-SMHAU","Q-SMRS","Q-SMRS_N-2","Q-SM_275BUS_CB","Q-ST_275BUS_CB","Q-X_2FNQ+3NQ+VC","Q-X_BSNE+CLST","Q-X_CLST+LCCP","S-ACPA","S-ACPA_BC-2CP","S-BG6538_6539_CB","S-BGBW","S-BRTX3","S-BWMP","S-BWMP_OFF","S-DAV_ROB_GEN_0","S-DAV_ROB_GEN_0100","S-DAV_ROB_GEN_0200","S-DAV_ROB_GEN_0300","S-DAV_ROB_GEN_0400","S-DAV_ROB_GEN_0500","S-DAV_ROB_GEN_0600","S-DAV_ROB_GEN_0700","S-DAV_ROB_GEN_0800","S-DAV_ROB_GEN_0900","S-DAV_ROB_GEN_1000","S-DAV_ROB_GEN_1100","S-DAV_ROB_GEN_1200","S-DAV_ROB_GEN_1300","S-DAV_ROB_GEN_1400","S-DAV_ROB_GEN_1500","S-MAMAP2","S-MAMAP2_BC-2CP","S-NIL","S-SMF1_BESS_BDU_ZERO","S-SMF2_BESS_BDU_ZERO","S-TB3_BESS_BDU_ZERO","S-TU_SE_GEN_0","S-TU_SE_GEN_0100","S-TU_SE_GEN_0200","S-TU_SE_GEN_0300","S-TU_SE_GEN_0400","S-TU_SE_GEN_0500","S-TU_SE_GEN_0600","S-TU_SE_GEN_0700","S-TU_SE_GEN_0800","S-TU_SE_GEN_0900","S-TU_SE_GEN_1000","S-TU_SE_GEN_1100","S-X_BWMP+MPPA","S-X_BWMP+MPPA_OFF","V-CPRC","V-DDTX1","V-DDTX1_DBUSS_T","V-DDTX2","V-DDTX2_DBUSS_T","V-DDTX3","V-DDWO_63","V-DDWO_X5","V-EL_ML_TG_GEN_0","V-EL_ML_TG_GEN_0100","V-EL_ML_TG_GEN_0200","V-EL_ML_TG_GEN_0300","V-EL_ML_TG_GEN_0400","V-EL_ML_TG_GEN_0500","V-EL_ML_TG_GEN_0600","V-EL_ML_TG_GEN_0700","V-EL_ML_TG_GEN_0800","V-EL_ML_TG_GEN_0900","V-EL_ML_TG_GEN_1000","V-EL_ML_TG_GEN_1100","V-EL_ML_TG_GEN_1200","V-EL_ML_TG_GEN_1300","V-EL_ML_TG_GEN_1400","V-EL_ML_TG_GEN_1500","V-EL_ML_TG_GEN_1600","V-EL_ML_TG_GEN_1700","V-NWVIC_GEN_0","V-NWVIC_GEN_0100","V-NWVIC_GEN_0200","V-NWVIC_GEN_0300","V-NWVIC_GEN_0400","V-NWVIC_GEN_0500","V-NWVIC_GEN_0600","V-NWVIC_GEN_0700","V-NWVIC_GEN_0800","V-NWVIC_GEN_0900","V-NWVIC_GEN_1000","V-NWVIC_GEN_1100","V-NWVIC_GEN_1200","V-NWVIC_GEN_1300","V-NWVIC_GEN_1400","V-NWVIC_GEN_1500","V-NWVIC_GEN_1600","V-NWVIC_GEN_1700","V-NWVIC_GEN_1800","V-NWVIC_GEN_1900","V-NWVIC_GEN_2000","V-NWVIC_GEN_2100","V-NWVIC_GEN_2200","V-NWVIC_GEN_2300","V-NWVIC_GEN_2400","V-NWVIC_GEN_2500","V-SWVIC_GEN_0","V-SWVIC_GEN_0100","V-SWVIC_GEN_0200","V-SWVIC_GEN_0300","V-SWVIC_GEN_0400","V-SWVIC_GEN_0500","V-SWVIC_GEN_0600","V-SWVIC_GEN_0700","V-SWVIC_GEN_0800","V-SWVIC_GEN_0900","V-SWVIC_GEN_1000","V-SWVIC_GEN_1100","V-SWVIC_GEN_1200","V-SWVIC_GEN_1300","V-SWVIC_GEN_1400","V-SWVIC_GEN_1500","V-SWVIC_GEN_1600","V-SWVIC_GEN_1700","V-SWVIC_GEN_1800","V-SWVIC_GEN_1900","V-SWVIC_GEN_2000","V-SWVIC_GEN_2100","V-SWVIC_GEN_2200","V-SWVIC_GEN_2300","V-SWVIC_GEN_2400","V-SWVIC_GEN_2500","V-SWVIC_GEN_2600","V-SWVIC_GEN_2700","V-SWVIC_GEN_2800","V-SWVIC_GEN_2900","V-SWVIC_GEN_3000","V-SWVIC_GEN_3100","V-SWVIC_GEN_3200","V-SWVIC_GEN_3300","V-SWVIC_GEN_3400","V-SWVIC_GEN_3500","V-SWVIC_GEN_3600","V-SWVIC_GEN_3700","V-SWVIC_GEN_3800","V-SWVIC_GEN_3900","V-TRGBESS1_BDU_ZERO","V-X_BAELML_BAML_B1CB"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the record for the given effective date","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"The person who authorised the constraint set","examples":["AASHFAQ","ABRAHAMY","AMULINGBAYAN","ANGROOM","ANL","BASHFORD","BATCH","BBLAKE","BCHHETRI","BOGDANV","BSANGHAVI","Batch","CPITT","CTOOMEY","DALJURE","DFARQUHAR","DGILMOUR","DHARVINL","DHOOLE","DPAT","FRANKB","GWEGENER","JAGUEST","JDUQUE","JHOO","JLOVERING","JRUFF","JWRIGHT","KHOUNSELL","KINW","KNGUYEN2","KPERERA","MATING","MBHASKAR","MINGCHENG","MJAMES2","MSHAKERI","MYANG","MYASAN","PARULS","RAMITHAW","RSHARMA2","RYANG","SHENGG","SNIEK","SPILLAY2","SRAJAPAKSE2","TERRYL","WSCHIE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time of authorising the constraint set","examples":["2026/09/01 02:06:54"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"COVERAGE":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"The region the constraint set is located in or a special grouping (e.g. CHIMERA)","examples":["CONSTRAINT AUTO","FCAS - GLOBAL","INTER-REGIONAL","NEGATIVE RESIDUE","NET SUPP AGREEMENTS","NON-CONFORMANCE","NSW1","QLD1","QUICK","SA1","TAS1","VIC1"]},"DESCRIPTION":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Description of the constraint","examples":[" 65_66 OL FOR 051 outage","0MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","0MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","0MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","0MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","0MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","0MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1000MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1000MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1000MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","100MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","100MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","100MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1100MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1100MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1100MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1200MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1200MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1300MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1300MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1400MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1400MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1500MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1500MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1600MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1600MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1700MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1700MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1800MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1900MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2000MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","200MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","200MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","200MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","2100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","300MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","300MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","300MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","3100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","400MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","400MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","400MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","500MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","500MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","500MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","600MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","600MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","600MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","600MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","700MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","700MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","700MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","700MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","800MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","800MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","800MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","800MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","900MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","900MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","900MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","900MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","Avoid overload on line 8U for NIL trip","Constraint Automation Set.  Generated by RTCA[EMS] Host BNEREGEEMP5(EMPBRI)","Constraint Automation Set.  Generated by RTCA[EMS] Host BNEREGEEMP6(EMPBRI)","Constraint Automation Set.  Generated by STNET[BNECR4] Host NORREGEEMP7(EMPSYD)","Constraint Automation Set.  Generated by STNET[NORCR1] Host BNEREGEEMP5(EMPBRI)","Constraint Automation Set.  Generated by STNET[NORCR1] Host BNEREGEEMP5(EMPBRI) 65/66 Margine increased to 50","Direction - Energy - No Intervention Pricing","Direction to allow charge but zero discharge for Bluegrass BESS for Dispatch and Predispatch and NOT PASA ","Direction to allow charge but zero discharge for Broadsound BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Broken Hill BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Bungama BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Calala BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Calala BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Clements Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Eraring BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Eraring BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Horsham Renewable Energy Park BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Liddell BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Limondale BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Lincoln Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mannum Stage 2 BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A1  for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A3 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mornington BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mortlake BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mugga Lane BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mugga Lane BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for New England BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for New England BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Orana BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Pine Lodge BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Quorn Park BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Stanwell BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Summerfield BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Summerfield BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Supernode BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Tailem Bend 3 battery for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Templers BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Terang BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Williamsdale BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Woolooga BESS  for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Bluegrass BESS for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Broadsound BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Broken Hill BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Bungama BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Calala BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Calala BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Clements Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Eraring BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Eraring BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Horsham Renewable Energy Park BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Liddell BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Limondale BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Lincoln Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mannum Stage 2 BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A1  for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A3 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mornington BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mortlake BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mugga Lane BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mugga Lane BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for New England BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for New England BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Orana BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Pine Lodge BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Quorn Park BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Stanwell BESS for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Summerfield BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Summerfield BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Supernode BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Tailem Bend 3 battery for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Templers BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Terang BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Williamsdale BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Woolooga BESS for Dispatch and Predispatch and NOT PASA ","Discretionary upper limit for Summerfield 1 BESS of 0 MW","Discretionary upper limit for Summerfield 2 BESS of 0 MW","Discretionary upper limit for Tailem Bend 3 BESS of 0 MW","GPWF 1 and 2 and 3 East limited to 250 MW","Limit Murraylink + Heywood + PEC to zero in either direction","Limit PEC to zero in either direction","Loss of 66 O/L 65 Margine of 50","Loss of 72 Line O/L 947","MLTS-TGTS 220kV Line","Minimum unit target for DUID BARKIPS1 required to provide system security for SSM Contract TS1_S00007 on 29/09/2026 10:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 1/09/2026 12:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 11/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 12/09/2026 10:05:00 PM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 12/09/2026 9:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 15/09/2026 7:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 17/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 18/09/2026 11:05:00 PM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 18/09/2026 4:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 22/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 23/09/2026 8:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 24/09/2026 12:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 24/09/2026 8:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 25/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 26/09/2026 4:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 28/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 4/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 6/09/2026 9:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 7/09/2026 11:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 8/09/2026 11:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 8/09/2026 9:05:00 PM","NSW to SA on PEC limited to 100 MW","NSW to SA on PEC limited to 150 MW","NSW to SA on PEC limited to 200 MW","NSW to SA on PEC limited to 250 MW","NSW to SA on PEC limited to 300 MW","NSW to SA on PEC limited to 350 MW","NSW to SA on PEC limited to 400 MW","NSW to SA on PEC limited to 450 MW","NSW to SA on PEC limited to 50 MW","NSW to SA on PEC limited to 500 MW","NSW to SA on PEC limited to 550 MW","NSW to SA on PEC limited to 600 MW","NSW to SA on PEC limited to 650 MW","NSW to SA on PEC limited to 700 MW","NSW to SA on PEC limited to 750 MW","NSW to SA on PEC limited to 800 MW","NSW1-QLD1 >= -429 (Ramping)","Negative Residue Management constraint set for V-SA, NSW1-QLD1, VIC1-NSW1, T-V-MNSP1 and NSW1-SA1","Non Conformance Constraint for TAILEM BEND 3 BESS","Non Conformance Constraint for WOOREEN BESS 1","Out = 6C, 6G, 6H 330kV lines","Out = 811 (H10 Bouldercombe to H73 Raglan) 275kV line","Out = 820 (H10 Bouldercombe to H20 Broadsound)  275kV line","Out = 821 275kV fdr H10 Bouldercombe - H11 Nebo","Out = 834 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 848 or 849 H10 Bouldercombe to H29 Stanwell 275 kV line","Out = 871 H24 Calvale to H40 Wurdong 275kV line","Out = 879 (H35 Strathmore to H91 Haughton) 275kV line","Out = 8846 or 8847 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 8857 or 8858 (H35 Strathmore to H13 Ross) 275kV line, CQ-NQ limits.","Out = 8874 or 8873 or 855 (H24 Calvale  to H29 Stanwell) 275kV feeder","Out = 8911 (H91 Haughton River to H13 Ross) 275kV line","Out = Armidale to Tamworth (86) line","Out = Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool","Out = Balranald to Buronga (X3) and Balranald to Darlington Point (X5) 220kV lines","Out = Balranald to Darlington Point (X5) 220kV line","Out = Balranald to Limondale 1 SF (X8) 220kV line","Out = Basslink Cable Load Prediction System (CLPS) dynamic rating data unavailable. Basslink limited to continuous ratings","Out = Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Blyth West- Munno Para 275kV line and Munno Para-Para 275kV (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Bungama - Blyth West 275kV line O/S, (Blyth West trip scheme I/S)","Out = Carwarp to Red Cliffs 220kV line","Out = Darlington Point 330/132 kV Transformer #1 and #2","Out = Dederang to Wodonga 330kV line O/S, 63 330kV line opened, X5 in service. See OM 526 and OM 608","Out = Dederang to Wodonga 330kV line O/S, X5 opened. See OM 526 and OM 608","Out = Jindera to Wodonga (060) line, Wagga-Yass 132kV network Split, 63 de-energised, X5 in service","Out = Jindera to Wodonga (060) line, Wagga-Yass 132kV network Split, X5 opened, 63 I/S","Out = Lower Tumut to Wagga (051) 330kV line, Wagga-Yass 132kV split, 9R3 + 9R4 + 63 open, and with 2 Yass Transformer in service","Out = Lower Tumut to Wagga (051) 330kV line, Wagga-Yass 132kV split, 9R3 + 9R4 + X5 open, and with 2 Yass Transformer in service","Out = Nil, NSW System Normal","Out = Nil, SA System Normal","Out = Nil, loss of both 8857 and 8858 (H35 Strathmore to H13 Ross) 275kV lines declared a credible contingency","Out = One 275kV Bus or one or more CB (89052,5812) at H13 Ross","Out = One H11 Nebo to H35 Strathmore 275KV line (822 / 878 / 8845)","Out = both Bundey to Buronga (6C and 6F) and both Buronga to Dinawan (6G and 6H) 330kV lines","Out = one 275kV Bus or one or more 275kV CB (88732,CB 88312,CB8492, CB8612, CB88742, CB8622, CB8632, CB8642, CB8562, CB8552) at Stanwell (H29)","Out = one 275kV Bus or one or more 275kV CB (CB8522, CB8712) at Calvale (H24)","Out = one 275kV Bus or one or more CB (CB8202, CB8342, CB88472, CB88312, CB8562, CB8332) at Broadsound (H20) ","Out = one 275kV Bus or one or more CB(8792,88452,88572,8782) at Strathmore (H35)","Out = one 275kV bus or one or more CB (8342,8222) at H11 Nebo","Out = one H20 Broadsound - H11 Nebo (834, 8846, 8720, 8846+8720, 8847) + one H24 Calvale - H29 Stanwell (855, 8873, 8874) 275kV line","Out = one H24 Calvale - H29 Stanwell (855, 8873, 8874) + H58 Larcom Creek - H67 Calliope River (8859) 275kV line","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series capacitors I/S)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series caps O/S)","Out= 818 H67 Calliope River to H40 Wurdong 275kV feeder, CQ-SQ voltage stability limit","Out= 8875 (H73 Raglan to H58 Larcom Creek) 275kV line","Out= 968 (Tamworth to Narrabri) and 96M(Narrabri to Moree) 132kV line","Out= Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Blyth West- Munno Para 275kV line and Munno Para-Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Bouldercombe to Calliope River (812), thermal limit equations for 811, 871 and 8859.","Out= Brinkworth 275/132kV TX3 transformer (with/without associated CBs 6530 & 6528& 6093 & 6068 OPEN).","Out= Bungama 275kV CB CB6538 OR CB6539 (NOTE: Only one CB O/S at a given time)","Out= Darlington Point to Wagga (63) 330kV line + 99J,99D,99L,9R4 opened","Out= Dederang H1 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Dederang H2 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= H13 Ross 275 kV SVC","Out= Larcom Creek to Calliope River (8859) 275kV line","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3)); (Both Black Range series capacitors O/S)","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3); (Both Black Range series capacitors I/S)","Out= Molong to Orange North (94T) 132kV line and Beryl to Crudine Ridge 132kV line (94M)","Out= Stubbo to Uungula (79) 330kV line","Out= Uungula to Wellington (7J) 330kV line","Out= one Darlington Pt 132/330kV TX1 or TX2","Out= up to two non-parallel 275kV lines between Ross-Woree, up to three non-parallel 275kV lines between Calvale-Ross, one/more 275kV bus or CB at H24 Calvale, H10 Bouldercombe, H29 Stanwell, H20 Broadsound, H11 Nebo, H35 Strathmore, H13 Ross, Ross SVC","Out=MLTS-TGTS 220kV line, trip of BATS-MLTS2 220kV line O/L BATS-MLTS1 220kV line","Out=MLTS-TGTS 220kV line, trip of BATS-MLTS2 220kV line O/L ELTS-MLTS 220kV line","Out=PEC loop closed, N-3 outages around PEC loop, 6C or 6F line plus 330 kV connection between Wagga and Buronga open. Feedback DS formulation","Out=PEC loop closed, N-3 outages around PEC loop, 6C or 6F line plus 330 kV connection between Wagga and Buronga open. Non-feedback DS formulation","Out=PEC loop closed, NIL major outages around PEC loop. Feedback DS formulation","Out=PEC loop closed, NIL major outages around PEC loop. Non-feedback DS formulation","Out=Wagga 330kV bus A. (Note: Wagga-Yass 132kV network split, X5 opened, with 2 Yass Transformer in service, Wagga-Darlington Pt open via 63 or 9R3+9HR+9HT)","Outage = Culcairn to Wagga (3G) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Outage = Culcairn to Wagga (3G) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Outage = Culcairn to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Outage = Culcairn to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Outage = Dederang No.1 330/220kV transformer","Outage = Dederang No.2 330/220kV transformer","Outage = Dederang No.3 330/220kV transformer","Outage = Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, Darlington Point-Wagga 132kV split, X5 + 63 + 9R4 + 996 open","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, 63 Open, 9R4 Open, and with 2 Yass TXs in service","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 Open, 9R4 Open, and with 2 Yass TXs in service","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 and 63 Open, 9R4 Open, and with 2 Yass TXs in service","QLD security issue","Qld CQ-NQArea Trf<=1000MW(Nebo+Dys);","Quick Constraint for energy","Quick Constraint for energy - Golden Plains EAST 1+2+3 Gen Requested lilimation","Quick Constraint for energy _Participant requested limitation of GPWF 1 and 2 and 3 East for 250MW for Testing","Quick constraint for Energy","Ramping Set for #VIC1_E_20260916 on 17/09/2026","Ramping Set for F-I_ML_APD_LOAD on 02/09/2026","Ramping Set for I-BURC_X1 on 01/09/2026","Ramping Set for I-BURC_X1 on 12/09/2026","Ramping Set for I-BURC_X1 on 14/09/2026","Ramping Set for I-BURC_X9 on 20/09/2026","Ramping Set for I-BURC_X9 on 21/09/2026","Ramping Set for I-HYSE on 07/09/2026","Ramping Set for I-HYSE on 09/09/2026","Ramping Set for I-ML_SV_EQ_020 on 02/09/2026","Ramping Set for I-ML_VS_EQ_020 on 02/09/2026","Ramping Set for I-ML_ZERO on 02/09/2026","Ramping Set for I-SVML_050 on 02/09/2026","Ramping Set for I-VSML_050 on 02/09/2026","Ramping Set for I-X_BABU_BURC on 12/09/2026","Ramping Set for I-X_BABU_BURC on 14/09/2026","Ramping Set for I-X_BDBU_BUDW on 28/09/2026","Ramping Set for N-966+KK on 08/09/2026","Ramping Set for N-ARTW_86 on 29/09/2026","Ramping Set for N-AVDT_10 on 20/09/2026","Ramping Set for N-BABU on 12/09/2026","Ramping Set for N-BADP on 04/09/2026","Ramping Set for N-BAMB_132_OPEN on 20/09/2026","Ramping Set for N-BANCO_973 on 17/09/2026","Ramping Set for N-BANCO_999 on 10/09/2026","Ramping Set for N-BANGOWF1_ZERO on 17/09/2026","Ramping Set for N-BANYS_9GL on 17/09/2026","Ramping Set for N-BECRD_94M on 14/09/2026","Ramping Set for N-BECRD_94M on 21/09/2026","Ramping Set for N-BU_CB7012 on 01/09/2026","Ramping Set for N-BWLD_ONE on 14/09/2026","Ramping Set for N-BWLD_ONE on 16/09/2026","Ramping Set for N-CHKS_ONE on 04/09/2026","Ramping Set for N-CHRL_9W3 on 05/09/2026","Ramping Set for N-CNCW_6_15M on 01/09/2026","Ramping Set for N-CNCW_6_15M on 09/09/2026","Ramping Set for N-CNCW_6_15M on 29/09/2026","Ramping Set for N-CRDMP-9ML on 27/09/2026","Ramping Set for N-CRWF1_ZERO on 27/09/2026","Ramping Set for N-DBWL_ONE on 08/09/2026","Ramping Set for N-DBWL_ONE on 09/09/2026","Ramping Set for N-DM_SVC on 29/09/2026","Ramping Set for N-DPTX1-2 on 07/09/2026","Ramping Set for N-DPTX1-2 on 14/09/2026","Ramping Set for N-DPYC-99D-C on 01/09/2026","Ramping Set for N-DP_TIETX on 21/09/2026","Ramping Set for N-DTKV_18_WG_CLOSE on 27/09/2026","Ramping Set for N-DTKV_18_WG_OPEN on 04/09/2026","Ramping Set for N-DTMN_8_15M on 14/09/2026","Ramping Set for N-DTSS_11 on 18/09/2026","Ramping Set for N-DTSS_11 on 19/09/2026","Ramping Set for N-ERA2_BESS_BDU_ZERO on 11/09/2026","Ramping Set for N-ERNC_90 on 13/09/2026","Ramping Set for N-ERVY_25 on 01/09/2026","Ramping Set for N-FINLYSF1_ZERO_INV on 04/09/2026","Ramping Set for N-GNNDHSF1_ZERO_INV on 10/09/2026","Ramping Set for N-GNNDHSF1_ZERO_INV on 13/09/2026","Ramping Set for N-KCMA_37 on 23/09/2026","Ramping Set for N-KKLS_967 on 07/09/2026","Ramping Set for N-KKLS_967 on 08/09/2026","Ramping Set for N-KS_132BS1 on 22/09/2026","Ramping Set for N-KS_132BS3 on 23/09/2026","Ramping Set for N-KVCW_3W_WG_CLOSE on 09/09/2026","Ramping Set for N-LDNC_81 on 22/09/2026","Ramping Set for N-LDTM_82 on 21/09/2026","Ramping Set for N-LDTW_84 on 29/09/2026","Ramping Set for N-LSLS_9U8 on 21/09/2026","Ramping Set for N-LS_VC1 on 21/09/2026","Ramping Set for N-LTWG_X5 on 04/09/2026","Ramping Set for N-MBTE_1 on 13/09/2026","Ramping Set for N-MORBOR on 02/09/2026","Ramping Set for N-MORBOR on 03/09/2026","Ramping Set for N-MORBOR on 08/09/2026","Ramping Set for N-MORBOR on 09/09/2026","Ramping Set for N-MORBOR on 13/09/2026","Ramping Set for N-MORBOR on 16/09/2026","Ramping Set for N-MORBOR on 22/09/2026","Ramping Set for N-MORBOR on 30/09/2026","Ramping Set for N-MPTX on 13/09/2026","Ramping Set for N-MPTX on 27/09/2026","Ramping Set for N-MPWO_5A5 on 24/09/2026","Ramping Set for N-NAGU on 23/09/2026","Ramping Set for N-NESBESS_BDU_ZERO on 16/09/2026","Ramping Set for N-SDUT_1 on 14/09/2026","Ramping Set for N-STUBSF_ZERO on 28/09/2026","Ramping Set for N-STUBSF_ZERO_INV on 28/09/2026","Ramping Set for N-SWVY_29 on 03/09/2026","Ramping Set for N-SWVY_29 on 25/09/2026","Ramping Set for N-TAGU_969 on 02/09/2026","Ramping Set for N-TAGU_969 on 03/09/2026","Ramping Set for N-TWNR_968 on 22/09/2026","Ramping Set for N-TW_330_BUS1 on 30/09/2026","Ramping Set for N-TW_SVC on 27/09/2026","Ramping Set for N-TW_SVC on 30/09/2026","Ramping Set for N-WLMO_945 on 28/09/2026","Ramping Set for N-WLMP_72 on 20/09/2026","Ramping Set for N-WLWLSF1_ZERO on 07/09/2026","Ramping Set for N-WOLLARSF1_ZERO on 28/09/2026","Ramping Set for N-WOLLARSF1_ZERO_INV on 28/09/2026","Ramping Set for N-WOODLWN1_ZERO on 07/09/2026","Ramping Set for N-WSTWYSF_ZERO on 13/09/2026","Ramping Set for N-WYASF1_ZERO on 13/09/2026","Ramping Set for N-X_6+DDSM on 29/09/2026","Ramping Set for N-X_966+KK+CH_CB892A on 09/09/2026","Ramping Set for N-X_BADP_DTKV on 04/09/2026","Ramping Set for N-X_BU_SC_4_5 on 12/09/2026","Ramping Set for N-X_TWNR_MORNR on 22/09/2026","Ramping Set for N-YCNA_9HT_C on 01/09/2026","Ramping Set for Q-810_PARALLEL_CLOSE on 30/09/2026","Ramping Set for Q-B2PSBRA_8840 on 02/09/2026","Ramping Set for Q-BKRL_8818 on 08/09/2026","Ramping Set for Q-BK_VC on 30/09/2026","Ramping Set for Q-BOUL_BESS_BDU_ZERO on 14/09/2026","Ramping Set for Q-BSNE on 06/09/2026","Ramping Set for Q-CLBTX on 01/09/2026","Ramping Set for Q-CLBTX on 03/09/2026","Ramping Set for Q-CN1000 on 11/09/2026","Ramping Set for Q-CN1000 on 15/09/2026","Ramping Set for Q-CN1000 on 16/09/2026","Ramping Set for Q-CPWO_BI_INTACT on 21/09/2026","Ramping Set for Q-CYPW on 15/09/2026","Ramping Set for Q-GLD4_0 on 21/09/2026","Ramping Set for Q-H11NE_SVC on 15/09/2026","Ramping Set for Q-H11NE_SVC on 16/09/2026","Ramping Set for Q-H11NE_SVC on 30/09/2026","Ramping Set for Q-H13RS_SVC on 15/09/2026","Ramping Set for Q-H13RS_SVC on 16/09/2026","Ramping Set for Q-H13RS_SVC on 23/09/2026","Ramping Set for Q-H35STM_SVC on 11/09/2026","Ramping Set for Q-H35STM_SVC on 21/09/2026","Ramping Set for Q-H35STM_SVC on 24/09/2026","Ramping Set for Q-HATR on 08/09/2026","Ramping Set for Q-HATR on 09/09/2026","Ramping Set for Q-HATR on 27/09/2026","Ramping Set for Q-KMBG_7184 on 07/09/2026","Ramping Set for Q-LCCP_8859 on 20/09/2026","Ramping Set for Q-LV_275_BUS_TX_2 on 24/09/2026","Ramping Set for Q-LV_275_BUS_TX_2 on 25/09/2026","Ramping Set for Q-MEBK_802 on 02/09/2026","Ramping Set for Q-MRTA_732 on 03/09/2026","Ramping Set for Q-MSPTS_7243 on 08/09/2026","Ramping Set for Q-NESTM on 11/09/2026","Ramping Set for Q-OKTA_7246 on 03/09/2026","Ramping Set for Q-OKTA_7247 on 09/09/2026","Ramping Set for Q-OKTA_7247 on 14/09/2026","Ramping Set for Q-PWSP_808 on 08/09/2026","Ramping Set for Q-PWSP_808 on 21/09/2026","Ramping Set for Q-RLSP_809 on 15/09/2026","Ramping Set for Q-SMSPL on 27/09/2026","Ramping Set for Q-SPL_TX_1 on 27/09/2026","Ramping Set for Q-SPL_TX_2 on 27/09/2026","Ramping Set for Q-STR_ALDSF_ZERO on 06/09/2026","Ramping Set for Q-STR_MOUSF1_ZERO on 24/09/2026","Ramping Set for Q-STR_MOUSF1_ZERO on 25/09/2026","Ramping Set for Q-TRME on 02/09/2026","Ramping Set for Q-TRME on 07/09/2026","Ramping Set for Q-TRME on 14/09/2026","Ramping Set for Q-TRME on 20/09/2026","Ramping Set for Q-TRME on 24/09/2026","Ramping Set for Q-TR_TG_842 on 20/09/2026","Ramping Set for Q-TR_TG_843 on 08/09/2026","Ramping Set for Q-TR_TG_844 on 06/09/2026","Ramping Set for Q-WOCY on 28/09/2026","Ramping Set for Q-WOCY on 29/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 11/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 15/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 16/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 23/09/2026","Ramping Set for Q-X_BSNE+CLST on 14/09/2026","Ramping Set for Q-X_BSNE_NESM on 11/09/2026","Ramping Set for Q-X_CLST+LCCP on 20/09/2026","Ramping Set for Q-X_HATR_TWO on 01/09/2026","Ramping Set for Q-X_HATR_TWO on 02/09/2026","Ramping Set for Q-X_HATR_TWO on 03/09/2026","Ramping Set for Q-X_HATR_TWO on 08/09/2026","Ramping Set for Q-X_HATR_TWO on 09/09/2026","Ramping Set for Q-X_METR+BKME on 02/09/2026","Ramping Set for Q-X_NE_STM_SVC on 15/09/2026","Ramping Set for Q-X_NE_STM_SVC on 16/09/2026","Ramping Set for Q-X_NE_STM_SVC on 30/09/2026","Ramping Set for Q-X_PWSP_CPWO on 21/09/2026","Ramping Set for Q-X_PWSP_CPWO_O on 23/09/2026","Ramping Set for Q-X_RS_TX_TX_C on 22/09/2026","Ramping Set for Q-X_RS_TX_TX_C on 25/09/2026","Ramping Set for Q-X_TRME_TRME on 07/09/2026","Ramping Set for Q-X_WOPW_WOGG_CL on 29/09/2026","Ramping Set for S-ACMA on 02/09/2026","Ramping Set for S-BC_CP on 05/09/2026","Ramping Set for S-BC_CP on 06/09/2026","Ramping Set for S-BC_CP on 07/09/2026","Ramping Set for S-BC_CP on 11/09/2026","Ramping Set for S-BC_CP on 12/09/2026","Ramping Set for S-BC_CP on 13/09/2026","Ramping Set for S-BC_CP on 15/09/2026","Ramping Set for S-BC_CP on 21/09/2026","Ramping Set for S-BG6538_6539_CB on 27/09/2026","Ramping Set for S-BG6538_6539_CB on 28/09/2026","Ramping Set for S-BRDV on 16/09/2026","Ramping Set for S-BR_CB6071 on 30/09/2026","Ramping Set for S-CGMS on 12/09/2026","Ramping Set for S-CGMS on 13/09/2026","Ramping Set for S-CGTI on 07/09/2026","Ramping Set for S-CGTI on 21/09/2026","Ramping Set for S-CGTI on 30/09/2026","Ramping Set for S-DC_CBG3 on 02/09/2026","Ramping Set for S-DVTX on 07/09/2026","Ramping Set for S-DVTX on 22/09/2026","Ramping Set for S-KHKN_BC-2CP on 05/09/2026","Ramping Set for S-KHKN_BC-2CP on 06/09/2026","Ramping Set for S-MGTI on 16/09/2026","Ramping Set for S-MGTI on 17/09/2026","Ramping Set for S-MSTU on 20/09/2026","Ramping Set for S-MWP3RB on 27/09/2026","Ramping Set for S-MWPS2-MWPS3 on 02/09/2026","Ramping Set for S-MWPS2-MWPS3 on 15/09/2026","Ramping Set for S-MWPS3-PV_0 on 22/09/2026","Ramping Set for S-NWCB6024+23 on 12/09/2026","Ramping Set for S-NWCB6024+23 on 15/09/2026","Ramping Set for S-NWCB6024+23 on 23/09/2026","Ramping Set for S-NWCB6024+23 on 27/09/2026","Ramping Set for S-NWCB6024+23 on 30/09/2026","Ramping Set for S-NWRB2 on 02/09/2026","Ramping Set for S-NWRB2 on 12/09/2026","Ramping Set for S-NWRB2 on 15/09/2026","Ramping Set for S-NWRB2 on 23/09/2026","Ramping Set for S-NWRB2 on 27/09/2026","Ramping Set for S-NWRB2 on 30/09/2026","Ramping Set for S-PATW on 22/09/2026","Ramping Set for S-PA_CB6509 on 06/09/2026","Ramping Set for S-PA_VC1 on 06/09/2026","Ramping Set for S-PA_VC1_BC-2CP on 06/09/2026","Ramping Set for S-SECB6611_10 on 16/09/2026","Ramping Set for S-SECB6611_10_BC-2CP on 21/09/2026","Ramping Set for S-SE_VC1 on 16/09/2026","Ramping Set for S-SE_VC1 on 18/09/2026","Ramping Set for S-SE_VC1 on 22/09/2026","Ramping Set for S-SE_VC1_BC-2CP on 21/09/2026","Ramping Set for S-TB2_TX on 07/09/2026","Ramping Set for S-TB2_TX on 21/09/2026","Ramping Set for S-TB2_TX on 30/09/2026","Ramping Set for S-TBSE on 07/09/2026","Ramping Set for S-TBSE on 11/09/2026","Ramping Set for S-TBSE on 12/09/2026","Ramping Set for S-TBSE on 13/09/2026","Ramping Set for S-TBSE on 15/09/2026","Ramping Set for S-TBSE on 21/09/2026","Ramping Set for S-TB_CB6123 on 16/09/2026","Ramping Set for S-TB_CB6536 on 02/09/2026","Ramping Set for S-TIBAT1_0 on 06/09/2026","Ramping Set for S-TINO3 on 22/09/2026","Ramping Set for S-TINO3 on 27/09/2026","Ramping Set for S-TITN1 on 22/09/2026","Ramping Set for S-TPBAT_0 on 27/09/2026","Ramping Set for S-TPBAT_0 on 28/09/2026","Ramping Set for S-X_BWMP+MPPA on 22/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 22/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 23/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 24/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 27/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 29/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 30/09/2026","Ramping Set for T-CSLI on 22/09/2026","Ramping Set for T-FATI on 27/09/2026","Ramping Set for T-GTSH on 15/09/2026","Ramping Set for T-HAPM_220 on 25/09/2026","Ramping Set for V-APHY_1 on 21/09/2026","Ramping Set for V-BALL_BESS_BDU_ZERO on 14/09/2026","Ramping Set for V-CPRC on 20/09/2026","Ramping Set for V-CPRC on 21/09/2026","Ramping Set for V-DBUSS_L on 02/09/2026","Ramping Set for V-DBUSS_L on 03/09/2026","Ramping Set for V-DBUSS_L on 04/09/2026","Ramping Set for V-DBUSS_L on 09/09/2026","Ramping Set for V-DBUSS_L on 10/09/2026","Ramping Set for V-DBUSS_L on 29/09/2026","Ramping Set for V-DBUSS_T on 02/09/2026","Ramping Set for V-DBUSS_T on 03/09/2026","Ramping Set for V-DBUSS_T on 04/09/2026","Ramping Set for V-DBUSS_T on 29/09/2026","Ramping Set for V-DDMS on 09/09/2026","Ramping Set for V-DDMS on 10/09/2026","Ramping Set for V-DDSM on 07/09/2026","Ramping Set for V-DDSM on 08/09/2026","Ramping Set for V-DDSM on 29/09/2026","Ramping Set for V-GNPL on 22/09/2026","Ramping Set for V-HM_VIC_ZERO on 03/09/2026","Ramping Set for V-HWRO3 on 03/09/2026","Ramping Set for V-HWRO3 on 13/09/2026","Ramping Set for V-HWSM on 01/09/2026","Ramping Set for V-HWSM on 02/09/2026","Ramping Set for V-HWSM on 04/09/2026","Ramping Set for V-HWSM on 05/09/2026","Ramping Set for V-HWSM on 06/09/2026","Ramping Set for V-HWSM on 17/09/2026","Ramping Set for V-HYTX_M12 on 22/09/2026","Ramping Set for V-HYTX_M12 on 27/09/2026","Ramping Set for V-HYTX_M12 on 28/09/2026","Ramping Set for V-LAVNTH1_ZERO on 04/09/2026","Ramping Set for V-LAVNTH1_ZERO on 05/09/2026","Ramping Set for V-LAVNTH1_ZERO on 18/09/2026","Ramping Set for V-LAVNTH1_ZERO on 19/09/2026","Ramping Set for V-LYPSA4_ZERO on 11/09/2026","Ramping Set for V-MLTX_A2 on 01/09/2026","Ramping Set for V-MTGELIBRAND_66 on 08/09/2026","Ramping Set for V-MTGELIBRAND_66 on 13/09/2026","Ramping Set for V-MTGELIBRAND_66 on 14/09/2026","Ramping Set for V-MTGELIBRAND_66 on 27/09/2026","Ramping Set for V-MTGELIBRAND_66 on 28/09/2026","Ramping Set for V-MTGELIBRAND_66 on 29/09/2026","Ramping Set for V-RANGEB_BDU_ZERO on 06/09/2026","Ramping Set for V-ROSM on 11/09/2026","Ramping Set for V-ROSM on 16/09/2026","Ramping Set for V-ROSM on 27/09/2026","Ramping Set for V-SALTCREEK_ZERO on 07/09/2026","Ramping Set for V-SMTX_F_R on 21/09/2026","Ramping Set for V-TRTS_BUS_CB_500 on 03/09/2026","Ramping Set for V-TSTT_R on 09/09/2026","Reference set to check system quantity, constraint never to bind","SA to NSW on PEC limited to 100 MW","SA to NSW on PEC limited to 150 MW","SA to NSW on PEC limited to 200 MW","SA to NSW on PEC limited to 250 MW","SA to NSW on PEC limited to 300 MW","SA to NSW on PEC limited to 350 MW","SA to NSW on PEC limited to 400 MW","SA to NSW on PEC limited to 450 MW","SA to NSW on PEC limited to 50 MW","SA to NSW on PEC limited to 500 MW","SA to NSW on PEC limited to 550 MW","SA to NSW on PEC limited to 600 MW","SA to NSW on PEC limited to 650 MW","SA to NSW on PEC limited to 700 MW","SA to NSW on PEC limited to 750 MW","SA to NSW on PEC limited to 800 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 0 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 100 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 120 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 140 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 160 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 180 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 20 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 200 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 220 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 240 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 260 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 270 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 280 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 300 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 340 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 350 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 40 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 400 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 420 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 450 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 470 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 500 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 520 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 540 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 550 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 560 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 580 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 60 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 600 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 620 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 640 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 650 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 660 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 680 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 700 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 720 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 740 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 750 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 760 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 780 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 80 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 800 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 820 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 840 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 850 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 870 MW","SA to Victoria on VicSA upper transfer limit of 500 MW","SA to Victoria on VicSA upper transfer limit of 550 MW","Stubbo #1 + #2 solar farm upper limit of 0 MW","Stubbo #1 + #2 solar farm upper limit of 0 MW and 0 Inverter","Terang BESS BDU zero Energy and FCAS","Vic/NSW to SA on Heywood + ML + PEC Minimum transfer limit of 700 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 0 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 100 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 120 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 140 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 160 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 180 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 20 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 200 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 220 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 240 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 260 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 280 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 300 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 320 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 340 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 360 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 380 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 40 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 400 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 420 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 440 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 460 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 480 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 500 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 550 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 60 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 600 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 620 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 650 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 700 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 720 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 740 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 750 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 760 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 780 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 80 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 800 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 820 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 840 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 850 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 870 MW","Victoria to SA on VicSA upper transfer limit of 500 MW","Victoria to SA on VicSA upper transfer limit of 570 MW","Victoria to SA on VicSA upper transfer limit of 600 MW","Victoria to SA on VicSA upper transfer limit of 650 MW","Wollar solar farm upper limit of 0 MW and 0 Inverter"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true},"MODIFICATIONS":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Details of the changes made to this version of the constraint set","examples":["Added  I_6F_NS_150 and I_6F_SN_150 and UFLS, ROCOF and OFGS from NIL sets. CCR10268","Added FCAS zero equations, CCR10234","Added MW/inverter conversion capping limit for Broken Hill BESS and Limondale BESS. CCR10223","Added MW/inverter conversion capping limit for Broken Hill BESS, Darling Point BESS, Limondale BESS, Riverina 1 & 2 BESS. CCR10223","Added MW/inverter conversion capping limit for Darling Point BESS, Riverina 1 & 2 BESS. CCR10223","Added MW/inverter conversion capping limit for Limondale BESS. CCR10223","Added PEC-2 NRM constraints. CCR10276","Added inverter indication equation for Carwarp SF; CCR10253","Added new thermal constraints managing txfmr flow from 220 to 330kV. CCR10212","Added new thermal equation. CCR10230","Added thermal equations monitoring line 85. CCR10272","Added voltage stability constraints per ElectraNet Mid-North 132kV Network Limit Advice (02/07/26). Updated thermal equations to include recently commissioned generators and added new thermal equations. Modified set and outage description. CCR10233","Added voltage stability constraints to set as per ElectraNet's Mid-north 132kV Network limit advice dated 02/07/26. Updated thermal equations in the set to include Tailem Bend 3 BESS and added new thermal equation.CCR10255","Added voltage stability constraints to set as per ElectraNet's Mid-north 132kV Network limit advice dated 02/07/26. Updated thermal equations in the set to include recently commissioned generators.CCR10227","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+2) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+3) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+3) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC. ","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+4) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10207 Add renamed system strength genconid","CCR10207 add renamed system strength equations","CCR10208 New","CCR10209 add renamed system strength genconid","CCR10216 Update NQLD system strength equations as per A38.d","Constraints updated to reflect latest advice on continuous ratings. Limits advice 21/5/26. CCR10202","Moved I_6F_NS_150 and I_6F_SN_150 to I-X_BDBU_BUDW. CCR10268","Moved UFLS, ROCOF and OFGS to I-X_BDBU_BUDWt. CCR10268","NEW","NEW; CCR10217","NSW,CCR10238","New","New DATASNAP INFO constraints for tracking Buronga PST tap positions; CCR10263","New DATASNAP constraints to track VIC and SA non forecast loads; CCR10271","New constraints for loop constraint LHS and RHS tracking; CCR10225","New set for PEC2 commissioning - based on I-BDBU_ONE. CCR10243","New, CCR10218","New, CCR10219","New, CCR10220","New, CCR10221","New, CCR10236","New, CCR10246","New, CCR10248","New, CCR10260","New, OM521, CCR10235","New. CCR10204","New. CCR10244","New. Includes  voltage stability limits as per ElectraNet's Mid-north 132kV Network limit advice- Ref to Viet Trinh email on 23/9/26. CCR10252","New; CCR10222","New; CCR10231","Removed N^^N_LTWG (not required until PEC2 energisation). CCR10264","Updated as per TG limit advice 23/09/2026, CCR10249","Updated description","Updated description only. CCR10235","Updated for PEC registration. CCR10250","Updated for PEC-2. CCR10250","Updated for PEC2 commissioning. CCR10247","Updated set description","Using DATA_MMS_ALERT1 to allow invocation of constraint prior to 1 Oct 2026. CCR10248"]},"OUTAGE":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Detail of the plant that is not in service","examples":[" * No transmission outages"," * discretionary upper limit for Laverton North Unit 1"," * discretionary upper limit for Loy Yang A Unit 4"," * discretionary upper limits for West Wyalong SF Generation"," * discretionary upper limits for Woodlawn Generation"," Dederang No.1 330/220kV transformer"," Dederang No.2 330/220kV transformer"," Dederang No.3 330/220kV transformer","* Discretionary upper limits for Hume VIC Generation","051 (Lower Tumut to Wagga) 330kV line 0/S, Wagga-Yass 132kV split, 9R3 + 9R4 + 63 open, and with 2 Yass Transformer in service","051 (Lower Tumut to Wagga) 330kV line 0/S, Wagga-Yass 132kV split, 9R3 + 9R4 + X5 open, and with 2 Yass Transformer in service","060 (Jindera to Wodonga) 330kV line O/S","33 or 34 (Bayswater to Liddell) 330kV line O/S, one line O/S only","7184 Kamerunga Barron Gorge PS 132kV line","7189 or 795 (T70 Cooroy to H9 Palmwood) 132kV feeder (section 1 or 2 or both)","7457(H35 Strathmore to T242 Springlands) 132kV line O/S","808 (H2 South Pine to H9 Palmwoods) 275 kV feeder O/S","808 (H9 Palmwoods to H2 South Pine) + 813 or 814 (H67 Calliope River to H5 Woolooga) 275kV lines","808 (H9 Palmwoods to H2 South Pine) + 813 or 814 (H67 Calliope River to H5 Woolooga) 275kV lines. Assume 132kV/110kV parallel between Woolooga - South Pine OPEN.","809 H16 Rocklea to H2 South Pine 275 kV feeder O/S","81 (Liddell to Newcastle) 330kV line","810 (H5 Woolooga to H9 Palmwoods) 275kV line+ 813/2 or 814/2 or 8850 ( H5 Woolooga to H6 Gin Gin or H63 Teebar Creek) 275kV lines","810 H9 Palmwoods to H5 Woolooga 275 kV feeder O/S with parallel 132 kV network intact","818 H67 Calliope River to H40 Wurdong 275kV feeder O/S","82 Liddell to Tomago 330kV line","837 and 8812 H18 Tarong to H12 Mt England 275 kV feeders O/S","837 or 8812 H18 Tarong to H12 Mt England 275 kV feeder O/S","84 (Liddell to Tamworth) 330kV line O/S","86 (Armidale to Tamworth) 330kV line O/S","871 H24 Calvale to H40 Wurdong 275kV line","879 (H35 Strathmore to H91 Haughton) 275kV line O/S","8818 H36 Blackwall to H16 Rocklea 275 kV feeder O/S","8857 or 8858 (H35 Strathmore to H13 Ross) 275kV line O/S","8911 (H91 Haughton River to H13 Ross) 275kV line O/S","967 (Koolkhan to Lismore) 132kV line O/S","9U8 or 9U9 or 9W1 132kV lines O/S","9W3 (Coffs Harbour to Raleigh) 132kV line O/S. Note: Auto detect PST status included","Alcoa Portland to Heywood No. 1 500 kV line only","Any 275 kV line between H24 Calvale  to H29 Stanwell outage","Any one 834, 8846, 8720, 8846+8720, 8847 (H20 Broadsound - H11 Nebo) + any one 855, 8873, 8874 (H24 Calvale - H29 Stanwell) 275kV line","Any one H24 Calvale - H29 Stanwell (855, 8873, 8874) + H58 Larcom Creek - H67 Calliope River (8859) 275kV line","Balranald to Buronga (X3) 220kV line","Balranald to Buronga (X3) and Balranald to Darlington Point (X5) 220kV lines","Balranald to Buronga (X3) and Buronga to Red Cliffs (X9) 220kV lines","Balranald to Darlington Point (X5) 220kV line","Balranald to Limondale 1 SF (X8) 220kV line","Bango 973 to Cowra(973)132kV line","Bango 999 WF to Cowra 132kV line (999)","Bango973 WF to Yass 132kV line(9GL)","Basslink Cable Load Prediction System (CLPS) dynamic rating data unavailable. Constraints to manage MW limits defined at receiving end.","Beryl to Crudine Ridge 132kV line (94M)","Bouldercombe to Calliope River (812) 275kV line","Burnie to Sheffield No.1 220kV line, West Coast 110 kV link between Farrell and Burnie open","Buronga 220kV CB7012","Central QLD outages","Crudine Ridge to MT Piper 132kV line (9ML)","DEFAULT","DEFAULT3","Dederang DBUSS-Line control scheme ","Dederang DBUSS-Transformer control scheme (System Normal and Prior Outage)","Dederang to Murray (DDTS - MSS) [67 or 68] 330kV line O/S, one line O/S only","Dederang to South Morang 330 kV line","Dederang to Wodonga 330kV line, 63 O/S","Dederang to Wodonga 330kV line, X5 O/S","Directlink - one Mullumbimby - Terranora DC cable O/S","Discretionary upper limit for SA WATER Morgan Whyalla Pump Station 3 PV generation of 0 MW","Discretionary upper limit for Summerfield 1 BESS of 0 MW","Discretionary upper limit for Tailem Bend 3 BESS of 0 MW","Discretionary upper limit for Torrens Island Battery of 0 MW","Discretionary upper limit on IBR within the NSW Buronga to Wagga area.","Discretionary upper limit on NSW to SA","Discretionary upper limit on SA to NSW","Discretionary upper limit on generators within North West Victoria (Bendigo-Ballarat-Red Cliffs area)","Discretionary upper limit on generators within South West Victoria (Moorabool to Heywood area)","Discretionary upper limit on generators within the Davenport to Robertstown area.","Discretionary upper limit on generators within the Elaine - Moorabool - Terang area.","Discretionary upper limit on generators within the Tungkillo to South East area.","Discretionary upper limits for Eraring BESS 2","Discretionary upper limits for Walla Walla solar farm 1 Generation","Discretionary upper limits on Bango 973 wind farm","Discretionary upper limits on Crudine Ridge wind farm","Discretionary upper limits on Finley solar farm","Discretionary upper limits on Gunnedah solar farm","Discretionary,Gladstone Unit 4 =< 0MW","Dry Creek 66kV CB G3","Dubbo132 to Wellington (94F or 94J ) 132 kV line","Dumaresq SVC","Eraring to Newcastle (90)","Feeder 813 or 814 between H67 Calliope River and H5 Woolooga","H10 Bouldercombe to H73 Raglan (811) 275kV line","H11 Nebo SVC","H12 Mt England - H36 Blackwall (802) 275kV line","H13 Ross 275 kV SVC O/S","H14 Middle Ridge to T147 Tangkam 732 110kV line O/S","H35 Strathmore SVC OOS","H36 Blackwall SVC O/S","H73 Raglan to H58 Larcom Creek (8875) 275kV line","Hazelwood to Rowville No.3 500kV line","Hazelwood to South Morang 500kV line","Kangaroo Valley to Capital (3W) line","Kemps Creek to Macarthur 330kV (37) line O/S","Kempsey 132kV bus #3","Kempsey 132kV bus section 1","Larcom Creek to Calliope River (8859) 275kV line","Liapootah to Chapel St 220kV line","Lismore SVC O/S","Load Event (APD)","Mt Gelibrand wind farm upper limit of 66 MW","Mt_Piper to Wellington (72) 330 kV line","Multiple NQLD outages","Multiple outage, both Bundey to Buronga (6C and 6F) and both Buronga to Dinawan (6G and 6H) 330kV lines","N-3 PEC Loop","NSW1 - to be used for zero MW for BESS for BDU Reliability directions","Nil","None","None. Zero facility dispatch","One 132 kV line between Ballina and Mullumbimby that opens the 132 kV path (9G2, 9G3, 9G4, 9G5 and Ballina 132/66kV Tx)","One 275kV Bus or one or more CB (89052,5812) at H13 Ross","One H20 Broadsound to H11 Nebo 275kV line (834 / 8846 / 8847) and one H11 Nebo to H35 Strathmore 275kV line (822 / 878 / 8845) O/S","One or more series 132kV feeder between H5 Woolooga and T70 Cooroy","One parallel 275kV fdr between H12 Mt England to H18 Tarong (837, 8812) + 802 (H36 Blackwall to H12 Mt England) 275kV fdr","Out = 5A5 (Wollar to Mt. Piper) 500kV line ","Out = 820 (H10 Bouldercombe to H20 Broadsound)  275kV line","Out = 821 275kV fdr H10 Bouldercombe - H11 Nebo,","Out = 834 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 842 Tarong  - Tarong Ps 275KV line.","Out = 843 Tarong  - Tarong PS 275KV line.","Out = 844 Tarong  - Tarong PS 275KV line.","Out = 848 or 849 H10 Bouldercombe to H29 Stanwell 275 kV line","Out = 8846 or 8847 (H20 Broadsound -H11 Nebo) 275kV line","Out = Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool","Out = Balranald to Darlington Point (X5) 220kV line and Dapto - Kangaroo Valley (18) 330kV line","Out = Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Blyth West- Munno Para 275kV line and Munno Para-Para 275kV (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Brinkworth - Davenport 275 kV line","Out = Bungama - Blyth West 275kV line O/S, (Blyth West trip scheme I/S)","Out = Canberra to Capital (6) 330kV line + one Dederang to South Morang (DDTS-SMTS) 330kV line O/S","Out = Carwarp to Red Cliffs 220kV line","Out = Dapto-Kangaroo Valley(18), [Note: Assumed Wagga-Yass OPEN (990 + 991 + 99P)]","Out = Darlington Point 330/132 kV Transformer #1 and #2","Out = Darlington Point to Yanco (99D) 132kV line.","Out = Georgetown to Sheffield 220kV line O/S, one line O/S only","Out = H11 Nebo SVC and H35 Strathmore SVC","Out = Hadspen to Palmerston (No.1 or No.2) 220kV line O/S, one line O/S only","Out = Heywood (HYTS) M1 or M2 500/275 kV txfmr","Out = Heywood to South East 275kV line  (Both Black Range series caps I/S)","Out = Keith - Kincraig 132 kV line  (Both Black Range series caps O/S)","Out = Lilyvale (H15) 275kV Bus no 1 or no2 and/or Lilyvale 275/132kV transformer 1 or 2 with 132kV network split between Baralaba and Moranbah , open fdrs 7114/1 at Baralaba end and 7382 and 7124/1 at Moranbah end","Out = Magill - Torrens Island 275 kV line","Out = Moorabool (MLTS) A2 500/220kV transformer O/S","Out = Morgan Whyalla Pipeline Pump No.3 - Robertstown 132kV line O/S, (Note: for Murraylink runback I/S or O/S).","Out = North West  Bend CBs 6023 and 6024 (Note:this offloads NWB-MWP1 132kV line),(Note: for Murraylink runback scheme I/S or O/S and Sever scheme I/S or O/S)","Out = North West Bend to Robertstown No.2 132kV line O/S,","Out = One H11 Nebo to H35 Strathmore 275KV line (822 / 878 / 8845)","Out = One South East-Tailem Bend 275kV line (One Black Range series cap I/S)","Out = Para - Templers West 275kV line","Out = South Morang 500/330kV F1 or F2 transformer, radial mode","Out = Torrens Island-New Osborne #3 66kV line (WITH/WITHOUT associated line CB I/S)","Out = both Buronga Syncon 4 & 5 (two syncons)","Out = either one of Black Range series capacitors bypassed,","Out = one 275kV Bus or one or more 275kV CB (8522, 8712) at Calvale (H24)","Out = one 275kV Bus or one or more 275kV CB (88732,CB 88312,CB8492, CB8612, CB88742, CB8622, CB8632, CB8642, CB8562, CB8552) at Stanwell (H29)","Out = one 275kV Bus or one or more CB (CB8202, CB8342, CB88472, CB88312, CB8562, CB8332) at Broadsound (H20) ","Out = one 275kV Bus or one or more CB(8792,88452,88572,8782) at Strathmore (H35)","Out = one 275kV bus or one or more CB (8342,8222) at H11 Nebo","Out = one of the Columboola 275/132 kV transformers(TX2 or TX3)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series capacitors I/S)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series caps O/S)","Out= 7243 Mt Stuart Power Station Townsville South 132kV line","Out= 7246 Oakey Tangkam 132kV line","Out= 7247 Oakey Tangkam 132kV line","Out= 966 (Armidale to Koolkhan) 132kV line [NOTE: Open at Koolkan end ONLY, Armidale end remains closed]  O/S and Coffs Harbour CB 892A opened - Arrangement 1 - see OM521","Out= 966 (Armidale to Koolkhan) 132kV line[NOTE: Open at Koolkan end ONLY, Armidale end remains closed] O/S - Arrangement 2 - see OM521","Out= 968 (Tamworth to Narrabri) and 96M (Narrabri to Moree) 132kV line","Out= 968 (Tamworth to Narrabri) and 96M(Narrabri to Moree) 132kV line","Out= 96M (Moree to Narrabri) 132kV line","Out= Angas Creek-Mannum 132kV line (Both Black Range series capacitors I/S); (Note:This offloads Mannum-Adelaide Pumping Station PVs 2 & 3)","Out= Any one 132kV feeder between Narrabri to Gunnedah Solar Farm (9UH, 9UJ, 9U3/2)","Out= Any one 275kV feeders between S2 Halys to H18 Tarong (8868,8869,8870,8871)","Out= Any two 275kV feeders between S2 Halys to H18 Tarong (8868,8869,8870,8871)","Out= Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Blyth West- Munno Para 275kV line and Munno Para-Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Brinkworth 132kV CB6071 Or Brinkworth 132kV East bus O/S","Out= Brinkworth 275/132kV TX3 transformer (with/without associated CBs 6530 & 6528& 6093 & 6068 OPEN).","Out= Bungama 275kV CB6538 OR CB6539 (NOTE: Only one CB O/S at a given time)","Out= Buronga to Red Cliffs (X1) 220kV line","Out= Buronga to Red Cliffs (X9) 220kV line","Out= Cherry Gardens - Mt Barker South 275kV line","Out= Dapto - Kangaroo Valley (18) [Note: Wagga-Yass 132kV parallel lines CLOSED]]","Out= Dederang H1 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Dederang H2 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Either one of  South East CB 6611 Or 6605 Or 6610 Or 6604 O/S (Both Black Range series caps I/S)","Out= Either one of  South East CB 6611 Or 6605 Or 6610 Or 6604 O/S (Both Black Range series caps O/S)","Out= Either one of  South East SVC O/S (Both Black Range series caps I/S)","Out= Either one of  South East SVC O/S (Both Black Range series caps O/S)","Out= Glenrowan to Pine Lodge 220kV line","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3)); (Both Black Range series capacitors O/S)","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3); (Both Black Range series capacitors I/S)","Out= Molong to Orange North (94T) 132kV line and Beryl to Crudine Ridge 132kV line (94M)","Out= Morgan Whyalla Pump 2 - Morgan Whyalla Pump 3 132 kV line","Out= Mt Barker South-Tungkillo 275kV line (Both Black Range series caps I/S)","Out= One Davenport 275/132kV TX O/S -- Refer to Electranet's OI E5.19","Out= One Para SVC (Note: With both black range series caps O/S)","Out= One of Coffs Harbour to Kempsey (9W5 or 9W6 or 9W7 or 9W8), Note: Auto detect PST status included","Out= Para 275kV CB6509 ","Out= Stubbo to Uungula (79) 330kV line","Out= Tailem Bend 275kV CB6536 O/S Only (Note: Other 275 kV CBs, all lines or Transformer at Tailem Bend are I/S)","Out= Tarrone 500kV bus CB (one CB only)","Out= Torrens Island to Cherry Gardens 275kV line","Out= Torrens Island to Torrens North #1 66kV line","Out= Uungula to Wellington (7J) 330kV line","Out= Wellington to Molong (945) 132kV line","Out= Yanco to Narrandera (9HT) 132kV line;  X5 Trip Scheme Disarmed, 132 kV parallel Solid, option c OM521","Out= one Darlington Pt 132/330kV TX1 or TX2, OM524","Out=968 (Tamworth to Narrabri) 132 kV Line ","Out=Farrell-Tribute 220KV line","Out=Tailem Bend 132kV CB 6123 O/S Only","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, 63 Open, 9R4 Open, and with 2 Yass TXs in service","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 Open, 9R4 Open, and with 2 Yass TXs in service","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 and 63 Open, 9R4 Open, and with 2 Yass TXs in service","Para SVC O/S, one SVC only","Prior outage of Avon to Dapto (10) 330kV line","Prior outage of Canberra to Capital (6) line","Prior outage of Dapto to Marulan (8) 330kV line","Prior outage of Dapto to Sydney South (11) 330kV line","Prior outage of Darlington Point to Wagga (63) 330kV line and 99J,99D,99L,9R4 132kV lines opened","Prior outage of Eraring to Vineyard (25) 330kV line","Prior outage of Stockdill to Upper Tumut (1) 330kV line","Prior outage of one Darlington Point 330/220/33 kV tie Tx (#3 or #4)","QLD1 - to be used for zero MW for BESS for BDU Reliability directions","R2 Braemar to H48 Braemar 2 PS 275kV line 8840","Rangebank BESS BDU Zero energy and FCAS","Rowville to South Morang 500kV line","SA1 - to be used for zero MW for BESS for BDU Reliability directions","Salt Creek wind farm upper limit of 0 MW","Springlands (TX1) 132/33kV transformer","Springlands (TX2) 132/33kV transformer","Sydney West to Vineyard (29) line","Tamworth No.1 330kV Bus O/S","Tamworth SVC","Tamworth to Gunnedah (969) 132kV line","Templers BESS BDU zero energy and FCAS","Terang BESS BDU zero Energy and FCAS","Thomastown to Templestowe 220 kV line","Torrens B unit 2 Transformer","Two Ross 275/132 kV transformer","Two non-parallel (8905 || (8916||8917 + 858||858 + 876||877|8902||8932)), three non-parallel (848||849 + 812||(811+8875+8859)||855||8873||8874 + 820||821 + 821||834||8846||8847 + 822||878||8845 + (879+8911)||8857||8858) + Ross SVC","VIC1 - to be used for zero MW for BESS for BDU Reliability directions","Wagga 330kV bus A. (Note: Wagga-Yass 132kV network split, X5 opened, with 2 Yass Transformer in service, Wagga-Darlington Pt open via 63 or 9R3+9HR+9HT)","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, Darlington Point-Wagga 132kV split, X5 + 63 + 9R4 + 996 open","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Wyalong Solar Farm upper limit of 0 MW","^ Multiple Outage, 6C, 6G, 6H 330kV lines","one of Mt Piper 500/330kV tie Tx."]},"SYSTEMNORMAL":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Not used as of 2005 End of Year Release [was Flag to indicate if the constraint set is a system normal (1) or and an outage set (0)]","examples":["0"],"unused":true,"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENCONSETTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":27770,"decompressed_size_all_time":34735710},"visibility":"Public","trigger":"Ad hoc"}