{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":1},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":2},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":1,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#49"],"comment":"MNSP_BIDOFFERPERIOD shows availability for 5-minute periods for a specific Bid and LinkID for the given Trading Date and period. MNSP_BIDOFFERPERIOD is a child to MNSP_DAYOFFER and links to BIDOFFERFILETRK for 5MS Bids.","primary_keys":["LINKID","OFFERDATETIME","PERIODID","TRADINGDATE"],"columns":{"LINKID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS","BLNKVIC"]},"OFFERDATETIME":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","examples":["2026/05/05 15:16:58.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period ID, 1 to 288","examples":["1","288"],"is_integer":true,"num_int_bits":16},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The trading date this bid is for","examples":["2026/07/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BANDAVAIL1":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 1","examples":["0"],"is_float":true},"BANDAVAIL2":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 2","examples":["0","100"],"is_float":true},"BANDAVAIL3":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 3","examples":["100"],"is_float":true},"BANDAVAIL4":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 4","examples":["100"],"is_float":true},"BANDAVAIL5":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 5","examples":["100"],"is_float":true},"BANDAVAIL6":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 6","examples":["100"],"is_float":true},"BANDAVAIL7":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 7","examples":["78","94"],"is_float":true},"BANDAVAIL8":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 8","examples":["0"],"is_float":true},"BANDAVAIL9":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 9","examples":["0"],"is_float":true},"BANDAVAIL10":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 10","examples":["0"],"is_float":true},"FIXEDLOAD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output, in MW. A value of NULL means no fixed load so the unit is dispatched according to bid and the market.","is_float":true},"MAXAVAIL":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum planned availability MW","examples":["0"],"is_float":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Allows for future use for Energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["438"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Ramp rate (MW / min) in the positive direction of flow for this MNSP link for this half-hour period","examples":["200"],"is_integer":true,"num_int_bits":32},"RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The advance notice(in hours) that a Scheduled Resource requires to achieve the PASA Availability MW for this trading interval","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MNSP_BIDOFFERPERIOD%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2021,"month":3},"last_month":{"year":2026,"month":7},"compressed_size_per_month":14101,"decompressed_size_all_time":62621908850},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The filenames of zips may not correspond to the tables. These can be mixed up with MNSP_PEROFFER. Check column 2 and 3 inside the CSV against `REPORT_NAME` and `REPORT_SUBTYPE` to be sure. I have already done this for you, and listed all URLs in [this metadata file](../../manifests/per_table/csv/MNSP_BIDOFFERPERIOD.csv).\n","category":"filenames"}],"trigger":"Generated as submissions are processed in next-day reports"}