{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONSUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#69"],"comment":"Region Results summary over aggregation periods.","description":"MTPASA_REGIONSUMMARY is public data.","primary_keys":["AGGREGATION_PERIOD","DEMAND_POE_TYPE","PERIOD_ENDING","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"AGGREGATION_PERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Period data is aggregated over. Values are YEAR, MONTH","examples":["MONTH","YEAR"]},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value are POE10, POE50","examples":["POE10","POE50"]},"PERIOD_ENDING":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime of day at end of period (i.e. last day of month or year reported)","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177","1184"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:29:02"],"parse_csv_as_string":true,"is_s_datetime":true},"LRC":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"LRC Condition reported (Value=1) if USE_WEIGHTED_AVG >= 0.002% otherwise (Value=0)","examples":["0","1"],"is_float":true},"NATIVEDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Native demand calculated from Operational As Generated trace supplied by Energy Forecasting","examples":["117314.69","869504","72933777.98","4547386"],"is_float":true},"NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Total number of iterations and reference years performed","examples":["600"],"is_float":true},"USE_AVERAGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average period unserved energy across iterations and reference years (MWh)","examples":["0.01","0","17","3988.47"],"is_float":true},"USE_EVENT_LOWERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower quartile unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","108","221"],"is_float":true},"USE_EVENT_MAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","669","4177.01"],"is_float":true},"USE_EVENT_MEDIAN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Median unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","1329.21"],"is_float":true},"USE_EVENT_MIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["0.13","0","521.41"],"is_float":true},"USE_EVENT_UPPERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Upper quartile unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","1908.27"],"is_float":true},"USE_NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Number of iterations and reference years showing unserved energy","examples":["0","1","57"],"is_float":true},"USE_PERCENTILE10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 10th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE20":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 20th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE30":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 30th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE40":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 40th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 50th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE60":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 60th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE70":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 70th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE80":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 80th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 90th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE100":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 100th percentile of iterations and reference years (MWh)","examples":["0.85","0","580","24241"],"is_float":true},"USE_WEIGHTED_AVG":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Weighted average USE per region = (USE_AVERAGE_POE10/NATIVE_DEMAND_POE_10*WEIGHT_POE_10 + USE_AVERAGE_POE50/NATIVE_DEMAND_POE_50*WEIGHT_POE_50)*100","examples":["0.000001","0","0.059534"],"is_float":true},"WEIGHT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed Values of 0.696 for 50 POE and 0.304 for 10 POE.","examples":["0.304","0.392"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONSUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":15684,"decompressed_size_all_time":26946360},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"}