{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGEDETAIL","VERSION":3},{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGEDETAIL","VERSION":4}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#15"],"comment":"Lists asset owners planned outages for transmission equipment. This also includes details for transmission equipment that will not have an outage, but associated secondary equipment has an outage and a related constraint set may be invoked. This scenario is indicated by the ISSECONDARY field in the table","primary_keys":["ELEMENTID","EQUIPMENTID","EQUIPMENTTYPE","OUTAGEID","STARTTIME","SUBSTATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"ELEMENTID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Equipment element id","examples":["16","9483"],"is_integer":true,"num_int_bits":64},"EQUIPMENTID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"A unique identifier for this equipment at this substation, and based on its type","examples":["01","0602A","7136","110KV_751","110KV_787","110KV_F826","132KV_7109","132KV_7110/1","132KV_7119","132KV_7121","132KV_7122/1","132KV_7126/1","132KV_7131","132KV_7150/1","132KV_7153","132KV_7155","132KV_7165","132KV_7168","132KV_7183","132KV_7238","1ACAP_1B_66","1BB_3B_220","1BCAP_66","1B_2AB_220","1CAP","1CAP_1B","1CAP_22","1CSC","1H","1TH","1TR","1_BANK_H6","1_H10","1_H11","1_H5","1_T13","1_T59","222G","232M","275KV_842","275KV_877","2BCAP_66","2CSC","2H","2TR","2_H5","2_T81","3ACAP_66","3B_4B_220","3CAP_22","3H","3_T136","3_T81","4B2","4H","4_H22","5432A","5A1","5GN","5H","5MN","5MN2","622B","7MN1","7MN2","7MN3","7MN4","8C","91J","95C","99L","A1TR_220","A1TR_4B","A2TR_2B_220","A2TR_500","A2_1B_220","A4GTR_2B","A4TR_1B_500","AL10","AL11","APD_HYTS1_500","APD_HYTS2_500","ATS_4B_220","B2TR","B3TR","B4TR","B4TR_66","B5TR","B5TR_66","BATS_BETS_220","BATS_MLTS1_220","BATS_MLTS2_220","BATS_TGTS_220","BETS_SHTS_220","BLTS_1B","BLTS_2B","BS_4122","BTS_RTS_220","C2","C5","CAP_4B_66","CB6005","CB6021","CB6022","CB6025","CB6033","CB6068","CB6079","CB6084","CB6085","CB6093","CB6135","CB6140","CB6141","CB6148","CB6149","CB6157","CB6158","CB6161","CB6188","CB6523","CB6527","CB6561","CB6562","CB6633","CBTS4_LYPS3","CPLR_4012","CPLR_5022","CPLR_5032","CPLR_5042","CPLR_5052","CPLR_5062","C_61","C_62","DDTS1_1B","DDTS1_2B","DDTS1_SHTS1","DDTS2_1B","DDTS2_2B","DDTS_1B","DDTS_MSS1_330","DDTS_SHTS_220","DDTS_SMTS1_330","DDTS_SMTS2_330","DDTS_WOTS_330","DPS_MBTS_220","EPS_TTS_220","ERTS2_2B","FDR_7042","FDR_71192","FDR_71222","FDR_71872","FDR_71882_1","FDR_7642","FDR_7862","FDR_8062","FDR_8132","FDR_8162","FDR_8182","FDR_8652","FDR_8712","GNTS_SHTS3_220","GTS3_3B","GTS3_B4TR","H2TR","HOTS_RCTS_220","HWPS2_1B","HWPS_ROTS1_220","HWPS_ROTS2_220","HWTS3_2B","HWTS4_3B","HWTS4_4B","HYTS_SESS1_275","HYTS_SESS2_275","JIND_1B","KILNOF_1","LYPS3_4B","MA3MAN_T","MAGEAT_1","MINWAT_1","MLRC_RCTS_220","MLTS_SYTS1_500","MOPS2_2B","MSS1_2B","MTBCHG_1","MWTS2_1B","N/A","NB","NPSDVP_1","OSBTOA_3","PARPGW_1","PAR_22","PEWLAG_1","ROBMW4_2","ROBNWB_1","ROTS3_3B","ROTS5_1B","ROTS5_2B","ROTS_RWTS_220","ROTS_SVTS2_220","ROTS_YPS6_220","ROTS_YPS7_220","ROTS_YPS8_220","RWTS_4B","SB","SCTR","SMTS1_1B","SMTS1_2B","SVC1","SVC2","TABKEI_1","TABKEI_2","TF1","TF2","TF9","TFMR_4412","TFMR_4422","TFMR_6422","TINTOA_1","TOANOF_1","TTS2_WMTS2","T_1","T_2","T_3","T_WT","W","WATTEM_1","WB66","X2","X3","X5/3"]},"EQUIPMENTTYPE":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of equipment. Valid values are:\nLINE = Line\nTRANS = Transformer\nCB = Circuit breaker\nISOL = Isolator\nCAP = Capacitor\nREAC = Reactor\nUNIT = Unit","examples":["BUS","CAP","CB","LINE","N/A","REACT","SVC","TRANS"]},"OUTAGEID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"ID uniquely identifying the outage","examples":["1002","25310"],"is_integer":true,"num_int_bits":64},"STARTTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The planned starting date and time of the outage","examples":["2002/10/31 10:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"The substation this equipment is located at","examples":["947TEE","ANG_CK","APD","ARMIDALE","AVON","BALRANLD","BATS","BAYSWATR","BETS","BLTS","BRINKW","BRKNHILL","BTS","BUNGAM","BURONGA","CANBERRA","CH_GDN","COLMBLLY","DAPTO","DAVENP","DDTS","DENILIQN","DPS","DUMARESQ","EPS","E_TCE","FBTS","GNTS","GTS","H10_BCMB","H11_NEBO","H13_ROSS","H15_LILY","H18_TRNG","H1_SBK_B","H22_LOGN","H2_SPINE","H32_CHLM","H39_WORE","H3_BELMT","H40_WURD","H5_WLGA","H6_GNGN","H7_GLAD","H9_PLMWD","HOTS","HUMMOC","HWPS","HWTS","HYTS","H_VALL","JINDERA","JLTS","KAR_H_PS","KEITH","KEMPSEY","KGTS","KILBUR","KINCRA","KTS","LADB_G","LYPS","MAGILL","MARULAN","MA_3","MBTS","MINTAR","MLRC","MLTS","MOBILO","MORP_E","MT_BAR","MT_PIPER","MUNMORAH","MURRAY","MW_4","N/A","NEWCSTLE","NORTHF","NPS","N_OSBN","N_W_B","OURIMBAH","PARA","PEAKHRST","PENO_W","PGWEST","PLAY","R2_BRAE","RCTS","ROTS","ROTS_500","RTS","RWTS","R_TOWN","SHTS","SMTS","SNUGGY","SSBBH","SSSPD","SVTS","SYD_EAST","SYD_STH","SYD_WEST","SYTS","S_EAST","T108_BNL","T111_NOR","T11_CBLT","T136_ABM","T137_NGY","T13_CHIN","T22_CALL","T26_BILO","T30_ASHW","T34_MRNB","T37_COLL","T38_MKAY","T39_PROS","T48_TLLY","T50_INFL","T55_TURK","T56_TV_S","T59_MRBO","T5_GLAD","T65_ALCK","T67_KMIS","T69_NLDS","T71_CLMT","T81_CADE","T93_CLS","TEMPLE","TGTS","TIPS_A","TI_N","TOMAGO","TRNG_PS","TTS","TUGGERAH","TUMUT1_2","T_BEND","VALES_PT","WAGGA132","WAGGA330","WELLNGTN","WOTS","W_LOO","YANCO","YASS","YPS"]},"ACTUAL_ENDTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The actual ending date/time of the outage","examples":["2003/04/28 09:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACTUAL_STARTTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The actual starting date/time of the outage","examples":["2002/10/31 14:19:00"],"parse_csv_as_string":true,"is_s_datetime":true},"COMPANYREFCODE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The asset owners reference code for this outage","examples":["068","3 TX","2003213","3M","3m","AS365957","AS369320","AS371098","AS372339","CC","CC2003229","DGP","E360419","ESP","ESP1","HVS 220403","NOTE","Q02S/1880","Q02W/0423","Q02W/0424","Q03I/1718","Q03I/2070","Q03I/2082","Q03I/2119","Q03O/0383","Q03O/0458","Q03O/0485","Q03O/0486","Q03O/0487","Q03O/0488","Q03O/0499","Q03O/0528","Q03O/0565","Q03O/0579","Q03O/0580","Q03O/0581","Q03O/0615","Q03O/0619,621","Q03O/062","Q03O/0622,623","Q03O/0624","Q03O/0625","Q03O/0626","Q03O/0627","Q03O/0628","Q03O/0629","Q03O/0630","Q03O/0631","Q03O/0633","Q03O/0634","Q03O/0635","Q03O/0637","Q03O/0641A-D","Q03S/0109","Q03S/0138","Q03S/0199","Q03S/0207","Q03S/0384","Q03S/0507","Q03S/0516","Q03S/0579","Q03S/0587","Q03S/0599","Q03S/0600","Q03S/0601","Q03S/0602","Q03S/0603","Q03S/0604","Q03S/0688","Q03S/0690","Q03S/0696","Q03S/0729","Q03S/0733","Q03S/0755B","Q03S/0760","Q03S/0775","Q03S/0844","Q03S/0848","Q03S/0864","Q03S/0865","Q03S/0866","Q03S/0868","Q03S/0869","Q03S/0878","Q03S/0888","Q03S/0893","Q03S/0902","Q03S/0903","Q03S/0904","Q03S/0906","Q03S/0914","Q03S/0915","Q03S/0916","Q03S/0917","Q03S/0918","Q03S/0919","Q03S/0920","Q03S/0921","Q03S/0926","Q03S/0932","Q03S/0938","Q03S/238","Q03W/0104","Q03W/0116","Q03W/0129","Q03W/0173","R03S/0261","RB 9","REF 0148","REF 0149","SSP0003","SSP0004","SSP0005","SSP0006","SSP0007","SSP0008","SSP0009","SSP0019","SSP0022","SSP0030","SSP0031","SSP0032","SSP0033","SSP0045","SSP0046","SSP0050","SSP0058","SSP0059","SSP0060","SSP0074","SSP0075","SSP0076","SSP0077","SSP0078","SSP0082","SSP0088","SSP0089","SSP0090","SSP0091","SSP0094","SSP0100 PART A","SSP0100 PART B","SSP0110","SSP0125","SSP0126","SSP0127","SSP0128","SSP0129","SSP0130","SSP0131","SSP0132","SSP0133","SSP0134","SSP0135","SSP9506","SSP9507","SSP9723","SSP9869","SSP9870","SSP9959","T37/71222","cc","ea2","rk"]},"ENDTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The planned ending date and time of the outage","examples":["2003/04/28 17:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ISSECONDARY":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"1 = The outage is for a secondary piece of equipment that has an associated constraint set. The transmission equipment is still in service. 0 = The outage is for the transmission equipment","examples":["0","1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed","examples":["2003/04/29 14:46:34.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"OUTAGESTATUSCODE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":false,"comment":"A code representing the status of the outage.\nThe OUTAGESTATUSCODE table will store a detailed description of each code.","examples":["COMPLETE","UTP","WDRAWN"]},"REASON":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"The reason provided by the asset owner for this outage","examples":["HV equipt maintenance","Secondary equipt maintenance"]},"RECALLTIMEDAY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The recall time in minutes during the day","examples":["0","-1","5","34560"],"is_integer":true,"num_int_bits":64},"RECALLTIMENIGHT":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The recall time in minutes during the night","examples":["0","-1","5","34560"],"is_integer":true,"num_int_bits":64},"RESUBMITOUTAGEID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The new outage id created from a resubmit.","examples":["1556","25310"],"is_integer":true,"num_int_bits":64},"RESUBMITREASON":{"sql_type":"VARCHAR(50)","pl_type":"str","mandatory":false,"comment":"Changes to an outage key details may require the outage to be resubmitted.\nA new outage id will then be allocated and the outage will be reassessed.\nThis field will detail the reason for the change.","examples":["Information Update","NEMMCO Request","Resource Problems","Weather"]},"SUBMITTEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this outage was first submitted","examples":["2003/04/29 12:04:46"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_OUTAGEDETAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":23791151,"decompressed_size_all_time":5714103760},"visibility":"Public"}