{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":4}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#37"],"comment":"The five-minute predispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The 5-minute Predispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_INTERCONNECTORSOLN sets out the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","description":"P5MIN_INTERCONNECTORSOLN is public data, so is available to all\nparticipants.\n\nSource\n\nP5MIN_INTERCONNECTORSOLN updates every 5 minutes.\n\nVolume\n\nRows per day: 1440\n\nBased on 200 interconnector/binding constraints per interval","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["F_T++NIL_ML_L6","N::Q_BWMP_LDTW","NQTE_ROC","TVBL_ROC","V::N_NIL_O2","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","VSML_ZERO","V^^N_NIL_1"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-0.00001","0.39022","0","39"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-0.00001","25.58031","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-119.69971","0","-121","-2478"],"is_float":true},"IMPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++BIP_ML_L1","F_MAIN++LREG_0210","F_T++NIL_MG_R6","I_6F_SN_150","N^^V_MLNK_ARWBBA","QNTE_ROC","Q^^N_NIL_SRAR","S:V_700_HY_TEST","SVML_ZERO","T_BLINK_TV_NGZ","V::N_NIL_O2","V>>NIL_SMTX_SMTX_R5","VTBL_NIL_CONT_441","VTBL_ROC","V_T_NIL_BL1"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-14.20862","7.10995","0","-700"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0)","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_INTERCONNECTORSOLN."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:00:33"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.36","4.51","0","-49"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.31","0","26912000","15.84"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor at the cleared flow","examples":["0.78351","1.29601"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of Interconnector standing data limits (if binding)","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SCADA MW Flow measured at Run start. For periods subsequent to the first period of a P5MIN run, this value represents the cleared target for the previous period of that P5MIN run.","examples":["-0.3","0.3","0","224"],"is_float":true},"MNSP":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating MNSP registration","examples":["0"],"is_boolean":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector loading level (MW)","examples":["-14.20861","7.10994","0","-969"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector Losses at cleared flow","examples":["-0.02722","0.03335","0","184.36565"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation of Interconnector standing data limits","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":15524445,"decompressed_size_all_time":19211877440},"visibility":"Public","trigger":"Every 5 minutes"}