{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"INTERCONNECTORSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#13"],"comment":"PD7DAY intereconnector solution","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","INTERVENTION","RUN_DATETIME"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run.","examples":["0"],"is_boolean":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["I_6F_NS_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^^N_NIL_WGLT","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_WEWT","S>NIL_MHNW1_MHNW2","T_V_NIL_FCSPS","V::N_HWRO3_O2","V::N_HWRO3_V2","V::N_HWSM_S1","V::N_HWSM_V2","V::N_MLTX_O2","V::N_MLTX_V2","V::N_NIL_O2","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","V>>SMF1_SMF2_NIL_R5","VSML_ZERO","VS_HEY_600_TEST","V^^N_CNCW_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-0.00001","0.50135","0","950"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-0.00001","44.98731","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-21.05416","0.00001","0","-2478"],"is_float":true},"IMPORTCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R60","I_6F_NS_150","I_6F_SN_150","N>>NIL_060_051","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_966/1_87_S","N^^N_NIL_WGLT","N^^V_CNCW_1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_ARWBBA","N_NIL_TE_B","Q>NIL_757_758_ECS","S:VS_800","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","SVML_ZERO","S_V_HEYWOOD_OFGS","S_V_NIL_ROCOF","T::T_NIL_3","T_ROCOF_3_3","V::N_HWRO3_V2","V::N_HWSM_S1","V::N_HWSM_V2","V::N_MLTX_V2","V::N_NIL_O2","V::N_NIL_V2","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DDTX3_DDTX2_DDTX1","V>>NIL_ELML_BAML2","V>>NIL_MLGT_MLGT","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>SMF1_SMF2_NIL_R5","V>>X9_WBBA_RCX1","VTBL_NIL_CONT_441","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V^^V_NIL_KGTS_2"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-21.05416","0.00001","0","-1247"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:12:38"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.32","0","-6","-26"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.33","0","23","8352000"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor at the cleared flow","examples":["0.42673","1.59769"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of Interconnector standing data limits (if binding)","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SCADA MW Flow measured at Run start. For periods subsequent to the first period of a PD7DAY run, this value represents the cleared target for the previous period of that PD7DAY run.","examples":["-2.991","0.50134","0","391"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector loading level (MW)","examples":["-2.991","0.50134","0","391"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector Losses at cleared flow","examples":["-0.0055","0.01123","0","132.15037"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation of Interconnector standing data limits","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_INTERCONNECTORSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":6199253,"decompressed_size_all_time":18261647300},"visibility":"Public","trigger":"Publishes few times per day"}