{"type": "object", "properties": {"INTERCONNECTORID": {"type": "string", "examples": ["N-Q-MNSP1", "NSW1-QLD1", "T-V-MNSP1", "V-S-MNSP1", "V-SA", "VIC1-NSW1"], "description": "Interconnector identifier"}, "INTERVAL_DATETIME": {"type": "string", "examples": ["2026/09/01 07:30:00"], "format": "date-time", "description": "The unique identifier for the interval within this study"}, "INTERVENTION": {"type": "boolean", "examples": ["0"], "description": "Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run."}, "RUN_DATETIME": {"type": "string", "examples": ["2026/09/01 07:30:00"], "format": "date-time", "description": "Unique Timestamp Identifier for this study"}, "EXPORTCONSTRAINTID": {"type": "string", "examples": ["I_6F_NS_150", "N::N_CNCW_2", "N::Q_BWMP_LDTW", "N::Q_BWMP_TNT", "N>NIL_LSDU", "N>Q-NIL_757_758", "NQ_950_TEST", "N^^N_NIL_WGLT", "S>>NIL_RBTU_RBTU", "S>>NIL_RBTU_WEWT", "S>NIL_MHNW1_MHNW2", "T_V_NIL_FCSPS", "V::N_HWRO3_O2", "V::N_HWRO3_V2", "V::N_HWSM_S1", "V::N_HWSM_V2", "V::N_MLTX_O2", "V::N_MLTX_V2", "V::N_NIL_O2", "V::N_NIL_V2", "V>>NIL_SMTX_SMTX_R5", "V>>SMF1_SMF2_NIL_R5", "VSML_ZERO", "VS_HEY_600_TEST", "V^^N_CNCW_1", "V_S_HEYWOOD_UFLS", "V_S_NIL_ROCOF"], "description": "Generic Constraint setting the export limit"}, "EXPORTLIMIT": {"type": "number", "examples": ["-0.00001", "0.50135", "0", "950"], "description": "Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit"}, "FCASEXPORTLIMIT": {"type": "number", "examples": ["-0.00001", "44.98731", "0", "2399"], "description": "Calculated export limit applying to energy + Frequency Controlled Ancillary Services."}, "FCASIMPORTLIMIT": {"type": "number", "examples": ["-21.05416", "0.00001", "0", "-2478"], "description": "Calculated import limit applying to energy + Frequency Controlled Ancillary Services."}, "IMPORTCONSTRAINTID": {"type": "string", "examples": ["F_MAIN++APD_TL_L5", "F_MAIN++APD_TL_L60", "F_Q++NIL_R1", "F_Q++NIL_R5", "F_Q++NIL_R6", "F_Q++NIL_R60", "F_T++NIL_CHWF_TG_R6", "F_T++NIL_MRWF_TG_R6", "F_T++NIL_WF_TG_R60", "I_6F_NS_150", "I_6F_SN_150", "N>>NIL_060_051", "N>>NIL_39", "N>>NIL_86_85_S", "N>>NIL_8U_86_S", "N>>NIL_964_84_S", "N>>NIL_966/1_87_S", "N^^N_NIL_WGLT", "N^^V_CNCW_1", "N^^V_MLNK_1", "N^^V_MLNK_ARWBBA", "N^^V_NIL_ARWBBA", "N_NIL_TE_B", "Q>NIL_757_758_ECS", "S:VS_800", "S:V_700_HY_TEST", "S>>MW2MW3_RBNW1", "SVML_ZERO", "S_V_HEYWOOD_OFGS", "S_V_NIL_ROCOF", "T::T_NIL_3", "T_ROCOF_3_3", "V::N_HWRO3_V2", "V::N_HWSM_S1", "V::N_HWSM_V2", "V::N_MLTX_V2", "V::N_NIL_O2", "V::N_NIL_V2", "V:T_NIL_BL_1", "V>>BELML_BAML1_BAML2", "V>>DDTX3_DDTX2_DDTX1", "V>>NIL_ELML_BAML2", "V>>NIL_MLGT_MLGT", "V>>NIL_SMTX_SMTX_R5", "V>>NIL_WBBA_KGBE", "V>>NIL_WBBA_RCWEKG", "V>>SMF1_SMF2_NIL_R5", "V>>X9_WBBA_RCX1", "VTBL_NIL_CONT_441", "V^^V_MLNK_KGTS", "V^^V_NIL_KGTS", "V^^V_NIL_KGTS_2"], "description": "Generic Constraint setting the import limit"}, "IMPORTLIMIT": {"type": "number", "examples": ["-21.05416", "0.00001", "0", "-1247"], "description": "Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow."}, "LASTCHANGED": {"type": "string", "examples": ["2026/09/01 07:12:38"], "format": "date-time", "description": "Last date and time record changed"}, "LOCAL_PRICE_ADJUSTMENT_EXPORT": {"type": "number", "examples": ["-0.32", "0", "-6", "-26"], "description": "Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)"}, "LOCAL_PRICE_ADJUSTMENT_IMPORT": {"type": "number", "examples": ["0.33", "0", "23", "8352000"], "description": "Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)"}, "LOCALLY_CONSTRAINED_EXPORT": {"type": "integer", "examples": ["0", "1", "2"], "maximum": 127, "minimum": -128, "description": "Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints"}, "LOCALLY_CONSTRAINED_IMPORT": {"type": "integer", "examples": ["0", "1", "2"], "maximum": 127, "minimum": -128, "description": "Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints"}, "MARGINALLOSS": {"type": "number", "examples": ["0.42673", "1.59769"], "description": "Marginal loss factor at the cleared flow"}, "MARGINALVALUE": {"type": "number", "examples": ["0"], "description": "Marginal cost of Interconnector standing data limits (if binding)"}, "METEREDMWFLOW": {"type": "number", "examples": ["-2.991", "0.50134", "0", "391"], "description": "SCADA MW Flow measured at Run start. For periods subsequent to the first period of a PD7DAY run, this value represents the cleared target for the previous period of that PD7DAY run."}, "MWFLOW": {"type": "number", "examples": ["-2.991", "0.50134", "0", "391"], "description": "Cleared Interconnector loading level (MW)"}, "MWLOSSES": {"type": "number", "examples": ["-0.0055", "0.01123", "0", "132.15037"], "description": "Interconnector Losses at cleared flow"}, "VIOLATIONDEGREE": {"type": "number", "examples": ["0"], "description": "Violation of Interconnector standing data limits"}}, "required": ["INTERCONNECTORID", "INTERVAL_DATETIME", "INTERVENTION", "RUN_DATETIME"], "description": "PD7DAY intereconnector solution"}