{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#10"],"comment":"PDPASA_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["#SSE_PPCCGT_20","$CPP_4","C_V_GPWFWST_462","I_6F_NS_150","I_6F_SN_150","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>94T_947_72","N>>NIL_39","N>>NIL_4","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_996_62","N>N-NIL_JUTX_LV","N>NIL_901","N>NIL_94K_1","N>NIL_94T","N>NIL_94T_72","N>NIL_969","N>NIL_9R6_991","N>NIL_LSDU","N>NIL_PKTX_LV","N^^N_NIL_1","N^^N_NIL_WGLT","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N_BERYLSF1_ZERO","N_NIL_TE_B","Q>NIL_757_758_ECS","Q>NIL_BCCP_LCCP","Q>NIL_CLWU_LCCP","Q>NIL_DRLCLB_NIL","Q>NIL_MRTA_C","Q>NIL_RGLC_BCCP","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","Q^^N_NIL_SRAR","Q_CS_2000","S:V_700_HY_TEST","S>>NIL_BWMP_WTTP","S>>NIL_RBTU_RBTU","S>>NIL_TWPA_TPRS","S>HUWT_BWPA_RHBR-T","S>V_NIL_SETX_SETX1","SVML_ZERO","S^CMWF_39","S^NIL_SA_NORTH","S^SNWWF_60","S_V_HEYWOOD_OFGS","T>T_NIL_BL_IMP_7CC","T^V_NIL_9","T^V_NIL_BL_6","T_MRWF_GCS","T_ROCOF_3_3","V::N_NIL_V2","V::V_1900","V>>BELML_BAML1_BAML2","V>>NIL_DDSM_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD2_MSDD1","V>>N_NIL_65_66","V>>SMF_SMF_ROTX1_R5","VSML_ZERO","VS_HEY_600_TEST","VTBL_NIL_CONT_441","V^^N_NIL_1","V_BURC_BANN1_SC_DYN","V_BURC_KARSF1_SC_DYN","V_BURC_WEMEN_SC_DYN","V_BURC_YATSF1_SC_DYN","V_DUNDWF1_2_3_168","V_NWVIC_GFT1_750","V_SH_DD_MAC_FLT_965","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are OUTAGE_LRC and LOR. Note that the PDPASA OUTAGE_LRC Run Type is discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":["LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["1"],"is_float":true},"CAPACITYRHS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The RHS value in the capacity evaluation.","examples":["-77.07","76.63","0","5051"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for generic constraint; 0 if not violating","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":2},"last_month":{"year":2026,"month":9},"compressed_size_per_month":26061507,"decompressed_size_all_time":20232417060},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"}