{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#76"],"comment":"PDPASA_INTERCONNECTORSOLN shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are OUTAGE_LRC and LOR. Note that the PDPASA OUTAGE_LRC Run Type is discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":["LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-27.99","0.59","0","1752"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-24.13","45.76","0","-1379"],"is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["0"],"is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints","examples":["-14.95","0.59","0","-1379"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for interconnector capacity; 0 if not violating","examples":["0"],"is_float":true},"EXPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Export Limit","examples":["I_6F_NS_150","I_6F_SN_150","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_39","N>>NIL_4","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^^N_NIL_1","N^^N_NIL_WGLT","S>>NIL_BWMP_WTTP","S>>NIL_RBTU_RBTU","S>>NIL_TWPA_TPRS","T^V_NIL_9","T^V_NIL_BL_6","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","V>>N_NIL_65_66","V>>SMF_SMF_ROTX1_R5","VSML_ZERO","VS_HEY_600_TEST","V^^N_NIL_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"IMPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Import Limit","examples":["I_6F_NS_150","I_6F_SN_150","N:V_NIL_BYYS","N>>NIL_23_22","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N^^N_NIL_WGLT","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N_NIL_TE_B","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q^^N_NIL_SRAR","S:V_700_HY_TEST","SVML_ZERO","S_V_HEYWOOD_OFGS","T_ROCOF_3_3","V::N_NIL_V2","V::V_1900","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DDTX3_DDTX2_DDTX1","V>>NIL_DDSM_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_MLSY_MLSY","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD2_MSDD1","V>>SMF_SMF_ROTX1_R5","VTBL_NIL_CONT_441","V^^V_NIL_KGTS"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":2},"last_month":{"year":2026,"month":9},"compressed_size_per_month":25655814,"decompressed_size_all_time":20398250750},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"}