{"type": "object", "properties": {"DATETIME": {"type": "string", "examples": ["2024/07/01 00:30:00"], "format": "date-time", "description": "Period date and time"}, "INTERCONNECTORID": {"type": "string", "examples": ["N-Q-MNSP1", "NSW1-QLD1", "T-V-MNSP1", "V-S-MNSP1", "V-SA", "VIC1-NSW1"], "description": "Unique interconnector identifier"}, "INTERVENTION": {"type": "boolean", "examples": ["0"], "description": "Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0\nWARNING: Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHINTERSENSITIVITIES."}, "INTERVENTION_ACTIVE": {"type": "boolean", "examples": ["0"], "description": "Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes"}, "LASTCHANGED": {"type": "string", "examples": ["2024/07/01 00:05:05"], "format": "date-time", "description": "Last date and time record changed"}, "MWFLOW1": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 1"}, "MWFLOW2": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 2"}, "MWFLOW3": {"type": "number", "examples": ["-0.68", "1.19", "0", "661"], "description": "MW flow for given Interconnector for scenario 3"}, "MWFLOW4": {"type": "number", "examples": ["-0.16", "0.06", "0", "600"], "description": "MW flow for given Interconnector for scenario 4"}, "MWFLOW5": {"type": "number", "examples": ["-0.45", "1.19", "0", "661"], "description": "MW flow for given Interconnector for scenario 5"}, "MWFLOW6": {"type": "number", "examples": ["-0.30", "0.23", "0", "600"], "description": "MW flow for given Interconnector for scenario 6"}, "MWFLOW7": {"type": "number", "examples": ["-0.45", "0.23", "0", "661"], "description": "MW flow for given Interconnector for scenario 7"}, "MWFLOW8": {"type": "number", "examples": ["-0.68", "0.71", "0", "520"], "description": "MW flow for given Interconnector for scenario 8"}, "MWFLOW9": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 9"}, "MWFLOW10": {"type": "number", "examples": ["-0.68", "1.90", "0", "500"], "description": "MW flow for given Interconnector for scenario 10"}, "MWFLOW11": {"type": "number", "examples": ["-0.68", "3.17", "0", "600"], "description": "MW flow for given Interconnector for scenario 11"}, "MWFLOW12": {"type": "number", "examples": ["-0.45", "0.08", "0", "247"], "description": "MW flow for given Interconnector for scenario 12"}, "MWFLOW13": {"type": "number", "examples": ["-1.36", "1.39", "0", "600"], "description": "MW flow for given Interconnector for scenario 13"}, "MWFLOW14": {"type": "number", "examples": ["-1.69", "1.83", "0", "335"], "description": "MW flow for given Interconnector for scenario 14"}, "MWFLOW15": {"type": "number", "examples": ["-0.68", "4.31", "0", "600"], "description": "MW flow for given Interconnector for scenario 15"}, "MWFLOW16": {"type": "number", "examples": ["-0.68", "0.84", "0", "600"], "description": "MW flow for given Interconnector for scenario 16"}, "MWFLOW17": {"type": "number", "examples": ["-0.68", "0.39", "0", "600"], "description": "MW flow for given Interconnector for scenario 17"}, "MWFLOW18": {"type": "number", "examples": ["-0.68", "5.34", "0", "520"], "description": "MW flow for given Interconnector for scenario 18"}, "MWFLOW19": {"type": "number", "examples": ["-0.68", "0.87", "0", "600"], "description": "MW flow for given Interconnector for scenario 19"}, "MWFLOW20": {"type": "number", "examples": ["-0.68", "0.03", "0", "520"], "description": "MW flow for given Interconnector for scenario 20"}, "MWFLOW21": {"type": "number", "examples": ["0"], "description": "MW flow for given Interconnector for scenario 21"}, "MWFLOW22": {"type": "number", "examples": ["0"], "description": "MW flow for given Interconnector for scenario 22"}, "MWFLOW23": {"type": "number", "examples": ["0"], "description": "MW flow for given Interconnector for scenario 23"}, "MWFLOW24": {"type": "number", "examples": ["0"], "description": "MW flow for given Interconnector for scenario 24"}, "MWFLOW25": {"type": "number", "examples": ["-0.68", "1.17", "0", "614"], "description": "MW flow for given Interconnector for scenario 25"}, "MWFLOW26": {"type": "number", "examples": ["-0.68", "4.25", "0", "600"], "description": "MW flow for given Interconnector for scenario 26"}, "MWFLOW27": {"type": "number", "examples": ["-0.37", "0.07", "0", "661"], "description": "MW flow for given Interconnector for scenario 27"}, "MWFLOW28": {"type": "number", "examples": ["-2.46", "1.31", "0", "600"], "description": "MW flow for given Interconnector for scenario 28"}, "MWFLOW29": {"type": "number", "examples": ["-0.20", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 29"}, "MWFLOW30": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 30"}, "MWFLOW31": {"type": "number", "examples": ["-0.68", "1.19", "0", "661"], "description": "MW flow for given Interconnector for scenario 31"}, "MWFLOW32": {"type": "number", "examples": ["-0.68", "2.20", "0", "600"], "description": "MW flow for given Interconnector for scenario 32"}, "MWFLOW33": {"type": "number", "examples": ["-0.45", "1.19", "0", "661"], "description": "MW flow for given Interconnector for scenario 33"}, "MWFLOW34": {"type": "number", "examples": ["-0.23", "3.17", "0", "600"], "description": "MW flow for given Interconnector for scenario 34"}, "MWFLOW35": {"type": "number", "examples": ["-0.55", "0.18", "0", "567"], "description": "MW flow for given Interconnector for scenario 35"}, "MWFLOW36": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 36"}, "MWFLOW37": {"type": "number", "examples": ["-0.11", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 37"}, "MWFLOW38": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 38"}, "MWFLOW39": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 39"}, "MWFLOW40": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 40"}, "MWFLOW41": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 41"}, "MWFLOW42": {"type": "number", "examples": ["-0.68", "1.19", "0", "600"], "description": "MW flow for given Interconnector for scenario 42"}, "MWFLOW43": {"type": "number", "examples": ["-0.68", "0.08", "0", "600"], "description": "MW flow for given Interconnector for scenario 43"}, "PERIODID": {"type": "string", "examples": ["1"], "description": "PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period."}, "PREDISPATCHSEQNO": {"type": "string", "examples": ["2024063041", "2024070601"], "description": "Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30"}, "RUNNO": {"type": "integer", "examples": ["1"], "minimum": 0, "maximum": 65535, "description": "LP Solver Predispatch run no, typically 1. It increments if the case is re-run."}}, "required": ["DATETIME", "INTERCONNECTORID"], "description": "PREDISPATCHINTERSENSITIVITIES sets out the sensitivity flows for each interconnector by period."}