{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_DATA","VERSION":1},{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_DATA","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#73"],"comment":"RESIDUE_CON_DATA supports the Settlement Residue Auction, by holding for each participant the confidential data from the auction. RESIDUE_CON_DATA joins to RESIDUE_PUBLIC_DATA and RESIDUE_TRK.","description":"Source\n\nRESIDUE_CON_DATA refreshes whenever a Settlement Residue Auction is run\n(i.e. quarterly).\n\nRESIDUE_CON_DATA data is confidential to the relevant participant.\n\nRESIDUE_CON_DATA excludes contracts and versions without a valid\npublication date (i.e invalid bids are ignored).\n\nVolume\n\nRESIDUE_CON_DATA shows a maximum of 6000 records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of Contracted Participant","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract run version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LINKPAYMENT":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment due (i.e. total purchase price)","is_float":true},"SECONDARY_UNITS_SOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The number of cancelled Units for all Auction Participants.","is_float":true},"UNITSPURCHASED":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Units purchased on the directional interconnector (i.e. Contracted quantity)","is_float":true}},"visibility":"Private","trigger":"On auction completion"}