{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_ACTUAL_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#153"],"comment":"Contains prediction runs for rooftop PV area estimated actuals, with a 5-minute and 30-minute resolution for different estimate types. This is the parent table to the child table ROOFTOP_PV_ACTUAL_PRED, which contains the corresponding actual predictions.","primary_keys":["AREAID","ESTIMATE_TYPE","INTERVAL_DURATION","OFFERDATETIME","PREDICTION_PRIORITY","PREDICTION_RUN_DATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"ESTIMATE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of Rooftop PV estimate, for example, MEASURED, SATELLITE and so on.","is_categorical":true},"INTERVAL_DURATION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Duration of each interval (in minutes) for this prediction, for example, 5 or 30.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this prediction submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDICTION_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Priority of prediction run, higher number is used in preference to lower number for the same provider.","is_integer":true,"unsigned_int":true,"num_int_bits":64},"PREDICTION_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) from which this prediction run is valid.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"INSTALLED_CAPACITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Installed rooftop PV capacity used for the prediction run, in MW.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the prediction run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the prediction run."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the prediction run."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the prediction run was suppressed by the provider when submitted. Suppressed predictions are not used by downstream forecasting systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true}},"visibility":"Public","trigger":"Every 5 or 30 minutes when a new rooftop PV estimated actual is available, covering the most recent 5 or 30-minute interval that is available"}