{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_REG_RESIDAMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#109"],"comment":"This report contains the FCAS Regulation Residue Amounts that include FPP Residual Amounts, Used Residual Amounts and Unused Residual Amounts calculated using the Energy Ratio for each Requirement Region.","primary_keys":["CONSTRAINTID","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Regulation Constraint ID","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The RegionId used for the residual calculation. This is the Constraint Requirement Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value that is used for the Residual Calculation.(Excluding CPID with CF)","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ASOE MWh value that is used for the FCAS Residual Calculation.(Excluding CPID with CF).","is_float":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType LOWERREG or RAISEREG for the Constraint ID","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ACE Amount calculated using the portion of ACE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"FPP_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"FPP_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of FPP_ACE_Amount + FPP_ASOE_Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ABS(ACE_MWh) + ASOE_MWh. The MWh is not netted for residual calculation.","is_float":true},"UNUSED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ACE Amount calculated using the portion of ACE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"UNUSED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"UNUSED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of UNUSED_ACE_AMOUNT + UNUSED_ASOE_AMOUNT.","is_float":true},"USED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used Recovery ACE Amount calculated using the ACE MWh value of the requirement regions.","is_float":true},"USED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used Recovery ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"USED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of USED_ACE_AMOUNT + USED_ASOE_AMOUNT.","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"}