{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"SCHEDULE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#37"],"comment":"Scheduled SSM contract enablements.","primary_keys":["INSTRUCTION_ID"],"columns":{"INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Instruction Identifier"},"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique Contract Identifier used to create enablement."},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"DUID_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Primary recipient (SSM Service Provider)","is_categorical":true},"END_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EQUIPMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit resource (for example, GENERATOR, LOAD, BIDIRECTIONAL, SYNCHRONOUS CONDENSER).","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MIN_DISPATCH_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Dispatch Target required for DUID to enable the contract.","is_float":true},"SERVICE_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Requested Service to provide(System strength-combination,System strength-coefficient,NSCAS-voltage control,NSCAS,Inertia,Transitional service-type 1 MSL,Transitional service-type 1,Transitional service-type 2)."},"START_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The first Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TNSP_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID of TNSP if contract procurer is TNSP.","is_categorical":true},"UNIT_COUNT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Number of sub-units within a DUID that are required for enablement.","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private","trigger":"Timed trigger once per day for previous day"}