{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#1"],"comment":"STPASA_CASESOLUTION holds one record containing results pertaining to each entire solution","description":"STPASA_CASESOLUTION is public data.\n\nSource\n\nSTPASA_CASESOLUTION is updated each STPASA run (i.e. every 2 hours).\n\nVolume\n\nRows per day: 12\n\nMb per month: \\<1","primary_keys":["RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CAPACITYOBJFUNCTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Objective Function from the Capacity Adequacy run","examples":["2958182.898","3572247","4436203.909"],"is_float":true},"CAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for capacity adequacy assessment. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"is_float":true},"INTERCONNECTORFLOWPENALTY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The penalty for non-zero interconnector flow","examples":["4.64"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was created or modified","examples":["2026/09/01 01:08:48"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"PASA\", \"MARKET\", \"Market\"])","mandatory":false,"comment":"Generation Availability to be used in LOR run (either PASA or MARKET)","examples":null,"enums":["PASA","MARKET","Market"]},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lack of Reserve Condition (LOR) flag for the case indicates the most severe condition in the case (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)","examples":["0"],"is_boolean":true,"unsigned_int":true,"num_int_bits":8},"LORDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for LOR assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["50"],"is_float":true},"LORUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["50"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"MAXSURPLUSRESERVEOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum surplus Reserve. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"is_float":true},"OUTAGELRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Outage LRC run (either PASA or MARKET)","examples":["Market"]},"OUTAGELRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for outage LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["10"],"is_float":true},"OUTAGELRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PASAVERSION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case","examples":["7.4.4.0"]},"RELIABILITYLRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"PASA\", \"MARKET\", \"Market\"])","mandatory":false,"comment":"Generation Availability to be used in Reliability LRC run (either PASA or MARKET)","examples":null,"enums":["PASA","MARKET","Market"]},"RELIABILITYLRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for Reliability LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["10"],"is_float":true},"RELIABILITYLRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Low Reserve Condition (LRC) flag for the case (1 - LRC in the case, 0 - No LRCs in the case) for capacity run","examples":["0","1"],"is_boolean":true},"MAXSPARECAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum Spare Capacity. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":11512,"decompressed_size_all_time":12427950},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"}