{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#10"],"comment":"STPASA_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.","description":"STPASA_CONSTRAINTSOLUTION is public data.\n\nSource\n\nSTPASA_CONSTRAINTSOLUTION is updated each STPASA run (i.e. every 2\nhours).\n\nVolume\n\nRows per day: 19000 (est.)\n\nMb per month: 90","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["#BBATTERY1_E1","#BRAEMAR1_E","#GREENB1_E1","#RANGEB1_E1","#WDBESS1_E1","C_S_CGBESS01_060_G","I_6F_NS_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_060_051","N>>NIL_23_22","N>>NIL_33_34","N>>NIL_39","N>>NIL_83_84_OPEN","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_996_62","N>NIL_901","N>NIL_94T","N>NIL_94T_72","N>NIL_969","N>NIL_993","N>NIL_998_18","N>NIL_9ML","N>NIL_9R4_62","N>NIL_9R6_991","N>NIL_LSDU","N>NIL_YSTX_LV","N>Q-NIL_757_758","N^^V_CNCW_1","N^^V_MLNK_1","N_BERYLSF1_ZERO","N_NIL_TE_B","Q>NIL_DRLCLB_NIL","Q>NIL_MRTA_C","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","Q^^TR_CLHA_-350","Q_B2PSBRA_8840","Q_MEWV_823_WIP1","Q_MEWV_823_WIV1","S-MAPS2-PV_0","S-MAPS3-PV_0","S-MWPS1-PV_0","S-MWPS2-PV_0","S-MWPS3-PV_0","S>NIL_NWRB2_NWRB1","SVML_ZERO","S_DC_CBG3","S_V_HEYWOOD_OFGS","TVBL_NIL_DYN","T_MRWF_GCS","V>>DDTX3_DDTX2_DDTX1","V>>N_NIL_65_66","VSML_ZERO","VS_HEY_600_TEST","VTBL_NIL","V^^N_NIL_1","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/02 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\", \"LOR\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC","LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"],"is_categorical":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["1"],"is_float":true},"CAPACITYRHS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The RHS value in the capacity evaluation.","examples":["-0.35","5.05","0","523"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for generic constraint; 0 if not violating","examples":["5.87","0","25.97"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 01:08:48"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":73679147,"decompressed_size_all_time":54132022040},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"}