{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#79"],"comment":"STPASA_INTERCONNECTORSOLN shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","description":"STPASA_INTERCONNECTORSOLN is public so is available to all participants.\n\nSource\n\nSTPASA_INTERCONNECTORSOLN is updated each STPASA run (i.e. every 2\nhours).\n\nVolume\n\nRows per day: 576\n\nMb per month: 4","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/05 01:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/03 02:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\", \"LOR\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC","LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"],"is_categorical":true},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-27.59","24.44","0","975"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-2.83","25.76","0","-1379"],"is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["0"],"is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints","examples":["-7.54","6.82","0","456"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for interconnector capacity; 0 if not violating","examples":["0"],"is_float":true},"EXPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Export Limit","examples":["I_6F_NS_150","I_6F_SN_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_33_34","N>>NIL_39","N>>NIL_83_84_OPEN","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^N_KKLS_1","Q>>NIL_MRTX4_MRTX5","Q^^TR_CLHA_-350","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_WEWT","S>>NIL_TWPA_TPRS","S>NIL_NWRB2_NWRB1","TVBL_NIL_DYN","V::N_DDSM_S2","V::N_LTWG_S2","V::S_SETB_TBSE_2","V>>DDMS_DDWO_DDMS","V>>DDSM_BABE_SMDD","V>>NIL_SMTX_SMTX_R5","V>>N_051+X5_65_66","V>>N_051+X5_66_65","V>>N_NIL_65_051","V>>N_NIL_65_66","VS_HEY_600_TEST","VS_V-SA_250","V^^N_BADP_1","V^^N_CNCW_1","V^^N_DDMS_1","V^^N_NIL_1","V_S_HEYWOOD_UFLS"],"is_categorical":true},"IMPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Import Limit","examples":["I_6F_NS_150","N::V_DDMS","N::V_DDSM_MSDD","N>967_96L_89_S","N>>9W7_9W2_965","N>>NIL_23_22","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_966/1_87_S","N^^N_NIL_WGLT","N^^V_BADP_1","N^^V_BADP_DTKV_1","N^^V_CNCW_1","N^^V_MSDD2","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_MBTE1_B","N_NIL_TE_B","Q:N_1078","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q^^N_NIL_SRAR","S:VS_800","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","SA_SETB_B","SVML_FLT_130","SV_250_LKB","S_V_HEYWOOD_OFGS","V>>DDSM_EPTT_DDSM","V>>DDSM_MBEP_DDSM","V>>DDSM_SHBE_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_SMTX_SMTX_R5","V>>X5_WBBA_KGBE","VTBL_NIL","V^^V_NIL_KGTS"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/03 02:08:47"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":83126010,"decompressed_size_all_time":58752171140},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"}