{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1231"],"comment":"STPASA_UNITSOLUTION shows the unit results from the capacity evaluations for each period of the study.","description":"STPASA_UNITSOLUTION was discontinued in the End Year 2005 MMS Release.\nSee Change Notice 512c for further details.\n\n \n\nSTPASA_UNITSOLUTION is confidential data.\n\nSource\n\nSTPASA_UNITSOLUTION is updated each STPASA run (i.e. every 2 hours).","unused":true,"primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC"]},"CAPACITYAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The available MW capacity for the period","is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for unit capacity; 0 if not violating","is_float":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier","is_categorical":true},"ENERGYAVAILABLE":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The energy limit (MWH) over this energy block for the energy constrained unit","is_integer":true,"num_int_bits":64},"ENERGYCONSTRAINED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"0 if not energy constrained, 1 if energy constrained for this energy block","is_boolean":true},"EXPECTEDMAXCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Max MW capacity that can be obtained in case of capacity scarcity from units subject to network and energy constraints.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"The physical plant capability including any capability that can be made available within 24 hrs","is_integer":true,"unsigned_int":true,"num_int_bits":64}},"visibility":"Private","trigger":"Each ST PASA run"}