{"package":"VOLTAGE_INSTRUCTIONS","pdr_config":{"mappings":[{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"TRACK","VERSION":1},{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"TRACK","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec75.htm#9"],"comment":"Parent record for Voltage Instructions (MVAr Dispatch). 'SIGNAL' records will have no children; 'INSTRUCTION' records will have children","primary_keys":["RUN_DATETIME","VERSION_DATETIME"],"indexes":[["RUN_DATETIME","VERSION_DATETIME"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"MVAr Interval - a timestamp of when instructions issued","examples":["2026/09/01 00:00:12"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime the file was published by VDS - Versions differ from Run_DateTime only for Supplemental runs","examples":["2026/09/01 00:00:12"],"parse_csv_as_string":true,"is_s_datetime":true},"EST_EXPIRY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Estimated expiry time of current Instruction set","examples":["2026/09/01 00:25:12"],"parse_csv_as_string":true,"is_s_datetime":true},"EST_NEXT_INSTRUCTION":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Estimated issue time of next Instruction set","examples":["2026/09/01 00:02:12"],"parse_csv_as_string":true,"is_s_datetime":true},"FILE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"SIGNAL\", \"INSTRUCTION\"])","mandatory":false,"comment":"Either 'SIGNAL' (childless) or 'INSTRUCTION'","examples":null,"enums":["SIGNAL","INSTRUCTION"]},"OPERATING_MODE":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Enum([\"AUTO\", \"AUTO-VERIFIED\", \"MANUAL\"])","mandatory":false,"comment":"The current VDS operating mode. Valid values: AUTO, AUTO-VERFIED, MANUAL","examples":null,"enums":["AUTO","AUTO-VERIFIED","MANUAL"]},"OPERATING_STATUS":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Unstructured code and message from AEMO","examples":["(1) VDS Active"]},"SE_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"State Estimator start time, when a snapshot is taken of SCADA values","examples":["2026/09/01 00:10:12"],"parse_csv_as_string":true,"is_s_datetime":true},"SOLUTION_CATEGORY":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Enum([\"NONE [No flag set]\", \"SUCCESS [solution succeeded]\", \"WARNING [solution completed with warnings]\", \"FAILURE\"])","mandatory":false,"comment":"VDS solver solution category. Valid values: SUCCESS, WARNING, FAILURE","examples":null,"enums":["NONE [No flag set]","SUCCESS [solution succeeded]","WARNING [solution completed with warnings]","FAILURE"]},"SOLUTION_STATUS":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Categorical","mandatory":false,"comment":"VDS solver solution status. Valid values: NOACTCNV [Solved with no instructions], NOVIOACT, CONVERGE, UNMANAGE, UNMANCTG, CTGDIV, SENHDIV [Failed with too many violations], BCDIV","examples":["CONVERGE [Solved with no violations]","CTGDIV [1 or more CTGs diverged]","NOACTCNV [Solved with no instructions]","NOVIOACT [Instructions with no violations]","UNMANCTG [Solved with CTG violations]"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23VOLTAGE_INSTRUCTION_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":78263,"decompressed_size_all_time":23055460},"visibility":"Public","trigger":"Signal or instructions issued"}