{"tables":{"ADG_DETAIL":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"ADG_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#1"],"comment":"Table for tracking evolving Aggregate Dispatch Group attributes","primary_keys":["ADG_ID","EFFECTIVEDATE","VERSION_DATETIME"],"columns":{"ADG_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Identifies the Aggregate Dispatch Group","examples":["ADP_ADG1","BALBESS_ADG1","BBATTERY_ADG1","BHBESS_ADG1","BOLIVAR_ADG1","BULGANA_ADG1","CBESS_ADG1","CBWW_ADG1","CHBESS_ADG1","DALNTH_ADG1","DPNTBESS_ADG1","GANNBESS_ADG1","HBESS1_ADG1","HORNSDPR_ADG1","HVWW_ADG1","KEP_ADG1","LBBESS_ADG1","PAREP_ADG1","PIBESS_ADG1","QBYNBESS_ADG1","QUORNPSH_ADG1","RESS1_ADG1","RESS2_ADG1","TB2HYB_ADG1","TIBESS_ADG1","VBB_ADG1","WALGBESS_ADG1","WANDBESS_ADG1","WDBESS_ADG1"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective calendar date of record","examples":["2023/08/09 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the version of Dispatchable Unit details","examples":["2023/08/04 15:39:42"],"parse_csv_as_string":true,"is_s_datetime":true},"ADG_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Conformance Type for the Aggregate Dispatch Group. One of the following: CAP, MIXED, TARGET","examples":["CAP","MIXED","TARGET"]},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["AEMO"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2023/08/04 15:39:40"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2023/08/04 15:39:42"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23ADG_DETAIL%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":766,"decompressed_size_all_time":200770},"visibility":"Public"},"AGGREGATE_DISPATCH_GROUP":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"AGGREGATE_DISPATCH_GROUP","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#7"],"comment":"Entity allowing for compliance monitoring over grouped DUIDs","primary_keys":["ADG_ID"],"columns":{"ADG_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Aggregate Dispatch Group ID","examples":["ADP_ADG1","BALBESS_ADG1","BBATTERY_ADG1","BHBESS_ADG1","BOLIVAR_ADG1","BULGANA_ADG1","CBESS_ADG1","CBWW_ADG1","CHBESS_ADG1","DALNTH_ADG1","DPNTBESS_ADG1","GANNBESS_ADG1","HBESS1_ADG1","HORNSDPR_ADG1","HVWW_ADG1","KEP_ADG1","LBBESS_ADG1","PAREP_ADG1","PIBESS_ADG1","QBYNBESS_ADG1","QUORNPSH_ADG1","RESS1_ADG1","RESS2_ADG1","TB2HYB_ADG1","TIBESS_ADG1","VBB_ADG1","WALGBESS_ADG1","WANDBESS_ADG1","WDBESS_ADG1"]},"COMMENTS":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A participant provided comment"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2023/08/04 15:39:42"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AGGREGATE_DISPATCH_GROUP%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":637,"decompressed_size_all_time":161690},"visibility":"Public"},"ANCILLARY_RECOVERY_SPLIT":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"ANCILLARY_RECOVERY_SPLIT","VERSION":1},{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"ANCILLARY_RECOVERY_SPLIT","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#1"],"comment":"ANCILLARY_RECOVERY_SPLIT holds the actual customer portion for each service and payment type. A single EFFECTIVEDATE/VERSIONNO combination applies to all services (i.e. the latest EFFECTIVEDATE/VERSIONNO is not retrieved for a single service, but applies to a data set).","description":"ANCILLARY_RECOVERY_SPLIT is public data, and is available to all\nparticipants.\n\nSource\n\nThis table is updated infrequently.","primary_keys":["EFFECTIVEDATE","PAYMENTTYPE","SERVICE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar settlement date record becomes effective.","examples":["2000/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PAYMENTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"A payment type associated with the service (can be ENABLING, AVAILABILITY, USAGE, or COMPENSATION).","examples":["AVAILABILITY","COMPENSATION","ENABLING","ENABLING60L","ENABLING60R","ENABLING6L","ENABLING6R","LOWER1SEC","LOWER5MIN","LOWER60SEC","LOWER6SEC","LOWERREG","RAISE1SEC","RAISE5MIN","RAISE60SEC","RAISE6SEC","RAISEREG","TESTING","USAGE"]},"SERVICE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Ancillary service name (e.g. AGC, FCASCOMP)","examples":["AGC","FCAS","FCASCOMP","GOVERNOR","LOADSHED","REACTIVE","RESTART","RGUL","RGUU"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of the record for the given date.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_PORTION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The percentage value of the recovery funded using the ACE MWh Values. This field is only used for Settlement post IESS rule effective date.","examples":["0","50","100"],"is_float":true},"CUSTOMER_PORTION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The percentage value of the recovery funded by market customers.","examples":["0","50","100"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2003/06/03 09:46:25"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23ANCILLARY_RECOVERY_SPLIT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1048,"decompressed_size_all_time":1231960},"visibility":"Public","trigger":"Updated infrequently. Occurs when details change"},"APCCOMP":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#1"],"comment":"APCCOMP is to set out Administered Price Cap (APC) compensation periods for a participant.","description":"APCCOMP is public data, and is available to all participants.\n\nSource\n\nAPCCOMP is empty until an Administered Price Cap event occurs.\n\nNot in use - never used","unused":true,"primary_keys":["APCID"],"indexes":[["LASTCHANGED"]],"columns":{"APCID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"APC event identifier."},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Settlement end date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Settlement end period (1-48)","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Settlement start date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Settlement start period (1-48)","is_integer":true,"num_int_bits":16}},"visibility":"Private","trigger":"When a Administered Price Cap event occurs"},"APCCOMPAMOUNT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#10"],"comment":"APCCOMPAMOUNT shows the Administered Price Cap (APC) compensation amount.","description":"Confidential to participants.\n\nSource\n\nUpdated with settlement positive and issued with daily data.\n\n \n\nNot in use - never used","unused":true,"primary_keys":["APCID","PARTICIPANTID","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"APCID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"APC Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":true,"comment":"Offset from start date and period in APCCOMP table.","is_integer":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation audit.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated with settlement posting"},"APCCOMPAMOUNTTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#19"],"comment":"APCCOMPAMOUNTTRK sets out the relevant Administered Price Cap (APC) period for compensation purposes. Use the APCCOMPAMOUNTTRK table in conjunction with APCAMOUNT.","description":"Public\n\nSource\n\nUpdated with settlement posting and issued with daily data.","unused":true,"primary_keys":["APCID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"APCID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"APC Identifier"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated with settlement posting"},"APEVENT":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"AP","REPORT_SUB_TYPE":"APEVENT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#1"],"comment":"APEVENT is the driving data defining the existence and timeframes of an administered pricing event.","primary_keys":["APEVENTID"],"indexes":[["LASTCHANGED"]],"columns":{"APEVENTID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Unique identifier for this administered pricing event","examples":["41","210"],"is_integer":true,"num_int_bits":128},"EFFECTIVEFROMINTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the first Dispatch Interval to which the administered event applies","examples":["2008/03/17 17:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVETOINTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the final Dispatch Interval to which the administered event applies","examples":["2008/03/18 04:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENDAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorising staff for end of AP event","examples":["ALANH","ApcManager","BFLEMING","BRIGONI","BWEBB","CBROWNLEE","IGNAZIOR","PRYAN","PSANDERS","RMOGG"]},"ENDAUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time end authorised","examples":["2008/03/17 17:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date-Time the record was last modified","examples":["2008/03/17 16:57:03"],"parse_csv_as_string":true,"is_s_datetime":true},"REASON":{"sql_type":"VARCHAR2(2000)","pl_type":"str","mandatory":false,"comment":"Description of the driver for the Event","examples":["AEMO has determined that the rolling sum of the uncapped dispatch prices for the SA region over the previous 336 trading intervals has exceeded the cumulative price threshold (CPT) of $216,900.00.","AEMO has determined that the rolling sum of the uncapped dispatch prices for the VIC region over the previous 336 trading intervals has exceeded the cumulative price threshold (CPT) of $216,900.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 1 Sec services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,823,600.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 6 Sec, Raise 6 Sec services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $221,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 60 Sec, Lower 6 Sec, Raise 6 Sec services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $221,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 60 Sec, Lower Reg, Raise Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 60 Sec, Raise 60 Sec, Lower Reg, Raise Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower 60 Sec, Raise Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $207,000.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $210,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg, Raise Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg, Raise Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $207,000.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Lower Reg, Raise Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $210,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Raise 5 Min, Lower 60 Sec, Raise 60 Sec, Lower Reg, Raise Reg services prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,398,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Raise 6 Sec services(s) prices for the QLD region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $224,600.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Raise 6 Sec services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $221,100.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Raise Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $207,000.00.","AEMO has determined that the rolling sum of the uncapped market ancillary Raise Reg services(s) prices for the SA region over the previous 2016 dispatch intervals has exceeded 6 times the cumulative price threshold (CPT) of $210,100.00.","AEMO has determined that the rolling sum of the uncapped spot prices for the NSW1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,359,100.00.","AEMO has determined that the rolling sum of the uncapped spot prices for the NSW1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,490,200.00.","AEMO has determined that the rolling sum of the uncapped spot prices for the QLD1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,359,100.00.","AEMO has determined that the rolling sum of the uncapped spot prices for the SA1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,359,100.00.","AEMO has determined that the rolling sum of the uncapped spot prices for the VIC1 region over the previous 2016 trading intervals has exceeded the cumulative price threshold (CPT) of $1,359,100.00.","CPT Exceeded in Tasmania","CPT exceeded","CPT exceeded ","CPT exceeded in South Australia","CPT exceeded in Vic","Continuation APP In accordance with NER Cl 3.14.2 (c) (1).NEMMCO has applied the APC for the next business day / trading day. Tuesday, 18 March 2008.","Extending APC to next trading day in SA1","Extending APC to next trading day in SA1.","RSP>CPT, therefore extending APC to next trading day.","extending APC to next trading day","extending APC to the next trading day"]},"STARTAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorising staff for start of AP event","examples":["ALANH","ApcManager","BFLEMING","BRIGONI","BWEBB","CBROWNLEE","IGNAZIOR","PRYAN","PSANDERS","RMOGG"]},"STARTAUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date-Time start authorised","examples":["2008/03/17 17:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23APEVENT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":10},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":4472,"decompressed_size_all_time":1243600},"visibility":"Public","trigger":"Administered pricing event"},"APEVENTREGION":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"AP","REPORT_SUB_TYPE":"APEVENTREGION","VERSION":1},{"REPORT_NAME":"AP","REPORT_SUB_TYPE":"APEVENTREGION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#9"],"comment":"APEVENTREGION is the Region detail for an administered pricing event defined through APEVENT.","primary_keys":["APEVENTID","REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"APEVENTID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Unique identifier for this administered pricing event","examples":["41","210"],"is_integer":true,"num_int_bits":128},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Date-Time of the first Dispatch Interval to which the administered event applies","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"ENERGYAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers an energy AP","examples":["0","1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the final Dispatch Interval to which the administered event applies","examples":["2008/03/17 16:57:03"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECAPFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the APEvent covers a Lower1Sec AP","examples":["1"],"is_boolean":true},"LOWER5MINAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a lower5min AP","examples":["1"],"is_boolean":true},"LOWER6SECAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a lower6sec AP","examples":["1"],"is_boolean":true},"LOWER60SECAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a lower60sec AP","examples":["1"],"is_boolean":true},"LOWERREGAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a lowerreg AP","examples":["1"],"is_boolean":true},"RAISE1SECAPFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the APEvent covers a Raise1Sec AP","examples":["1"],"is_boolean":true},"RAISE5MINAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a raise5min AP","examples":["1"],"is_boolean":true},"RAISE6SECAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a raise6sec AP","examples":["1"],"is_boolean":true},"RAISE60SECAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a raise60sec AP","examples":["1"],"is_boolean":true},"RAISEREGAPFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"flag indicating if the apevent covers a raisereg AP","examples":["1"],"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23APEVENTREGION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":10},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":1697,"decompressed_size_all_time":493800},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Administered pricing event"},"AREA":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"AREA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#1"],"comment":"Table containing static metadata for the Areas, which are sub-regions used in load forecasting and rooftop PV forecasting. The latest metadata can be obtained for each AreaID using the most recent EffectiveDate and then VersionNo. If an AreaID is not mapped to an active RegionID in the corresponding REGION_AREA table, then that AreaID can be considered inactive.","primary_keys":["AREAID","EFFECTIVEDATE","VERSIONNO"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Area identifier"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar date from when this record set is effective.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the same effectivedate.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AREA_DESCRIPTION":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Area description"},"AREA_NAME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Area name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Ad hoc when Areas are updated or added"},"AUCTION":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#1"],"comment":"AUCTION holds auction details. AUCTION is new in March 2003 to support SRA Inter-Temporal Linking.","description":"AUCTION is public data, and is available to all participants.\n\nSource\n\nStatic.\n\nVolume\n\n4 records per year","primary_keys":["AUCTIONID"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Unique id for each auction date","examples":["A202609"]},"AUCTIONDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Auction date","examples":["2026/09/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"examples":["SYSTEM"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/08/13 10:50:05"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DESCRIPTION":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Description of an auction"},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Close date for bidding","examples":["2026/09/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/09/15 14:16:04"],"parse_csv_as_string":true,"is_s_datetime":true},"NOTIFYDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Open date for bidding","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AUCTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":3},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":432,"decompressed_size_all_time":392070},"visibility":"Public","trigger":"Updated quarterly"},"AUCTION_CALENDAR":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_CALENDAR","VERSION":1},{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_CALENDAR","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#10"],"comment":"AUCTION_CALENDAR holds the definitions of each auction quarter in a contract year. AUCTION_CALENDAR supports the Settlement Residue Auction.","description":"AUCTION_CALENDAR is public data, and is available to all participants.\n\nSource\n\nUpdates are usually quarterly by the SRA team.\n\nVolume\n\nAUCTION_CALENDAR shows a maximum of 16 records per year.","primary_keys":["CONTRACTYEAR","QUARTER"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","examples":["2032"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","examples":["4"],"is_integer":true,"num_int_bits":8},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Last day of SRA Contract Quarter expressed as Date","examples":["2032/12/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"FINALPROCEEDSSTMTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"The date the Final Proceeds Statement is generated","examples":["2032/10/20 00:00:00"],"parse_csv_as_string":true,"is_date":true},"FINALPURCHASESTMTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"The date the Final Purchase Statement is generated","examples":["2032/10/18 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NOTIFYDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Default notification date","examples":["2029/12/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PAYMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date for payment by Participant","examples":["2032/10/20 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PRELIMPROCEEDSSTMTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"The date the Prelim Proceeds Statement is generated","examples":["2032/10/07 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PRELIMPURCHASESTMTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"The date the Prelim Purchase Statement is generated","examples":["2032/10/07 00:00:00"],"parse_csv_as_string":true,"is_date":true},"RECONCILIATIONDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date of reconciliation for the quarter","examples":["2033/02/04 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"First day of SRA Contract Quarter expressed as Date","examples":["2032/10/01 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AUCTION_CALENDAR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":491,"decompressed_size_all_time":328060},"visibility":"Public","trigger":"Updated quarterly"},"AUCTION_IC_ALLOCATIONS":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_IC_ALLOCATIONS","VERSION":1},{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_IC_ALLOCATIONS","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#19"],"comment":"AUCTION_IC_ALLOCATIONS supports the Settlement Residue Auction by providing the basis for setting up contracts for individual tranches. AUCTION_IC_ALLOCATIONS shows the default definitions for the total number of units and proportion applicable to each directional interconnector for a specified auction quarter.","description":"AUCTION_IC_ALLOCATIONS is public data, and is available to all\nparticipants.\n\nSource\n\nUpdates are usually quarterly as auctions are held from Settlement\nResidue Auction team's SRIS interface.\n\nVolume\n\nAUCTION_IC_ALLOCATIONS contains a maximum of 100 records per year.","primary_keys":["CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","QUARTER","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","examples":["2032"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector Identifier","examples":["NSW1-QLD1","NSW1-SA1","T-V-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","examples":["4"],"is_integer":true,"num_int_bits":8},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data takes precedence","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUCTIONFEE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Daily auction fee","examples":["0"],"is_float":true},"AUCTIONFEE_SALES":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Fees for Cancelled Units.","is_float":true},"CHANGEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Authorisation date","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"CHANGEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of person authorising this data set","examples":["SYSTEM"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXIMUMUNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Number of units on the interconnector","examples":["500","1500"],"is_integer":true,"num_int_bits":32},"PROPORTION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Percentage of the total residue for each Unit","examples":["0.06666","0.2"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AUCTION_IC_ALLOCATIONS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":591,"decompressed_size_all_time":655610},"visibility":"Public","trigger":"Usually quarterly after each settlement residue auction"},"AUCTION_REVENUE_ESTIMATE":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_REVENUE_ESTIMATE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#28"],"comment":"AUCTION_REVENUE_ESTIMATE supports the Settlement Residue Auction, by holding the evaluator’s estimates of revenue for each month of a given quarter.\nSince reserve prices are no longer applicable from the end of 2001, zero is used as a default to avoid rewriting the system.","description":"AUCTION_REVENUE_ESTIMATE is public data, and is available to all\nparticipants.\n\nSource\n\nUpdates are quarterly from SRA team via SRIS interface\n\nVolume\n\nAUCTION_REVENUE_ESTIMATE contains a maximum of 300 records per year.","primary_keys":["CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","MONTHNO","QUARTER","VALUATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"MONTHNO":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Month number within quarter (1..3)","is_integer":true,"unsigned_int":true,"num_int_bits":8},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","is_integer":true,"num_int_bits":8},"VALUATIONID":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":true,"comment":"Identifier of the estimator"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data will take precedence","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last day of month as date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REVENUE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated Revenue","is_float":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"First day of month as date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Updated quarterly"},"AUCTION_REVENUE_TRACK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_REVENUE_TRACK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#37"],"comment":"AUCTION_REVENUE_TRACK supports the Settlement Residue Auction, by holding the tracking information for each evaluator’s estimates for a given quarter. The status field is dynamic and is used for selection of estimates to be published.","description":"AUCTION_REVENUE_TRACK is public data, and is available to all\nparticipants.\n\nSource\n\nUpdates are quarterly after SRA team updates SRIS interface.\n\nVolume\n\nAUCTION_REVENUE_TRACK contains a maximum of 100 records per year.","primary_keys":["CONTRACTYEAR","QUARTER","VALUATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","is_integer":true,"num_int_bits":8},"VALUATIONID":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":true,"comment":"Identifier of the estimator"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data takes precedence","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of person authorising this record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of authorisation for this record","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DOCUMENTREF":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Reference to methodology document"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date from which the record change is applicable","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Internal use"}},"visibility":"Public","trigger":"Updated quarterly"},"AUCTION_RP_ESTIMATE":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_RP_ESTIMATE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#46"],"comment":"AUCTION_RP_ESTIMATE supports the Settlement Residue Auction, by holding the evaluator’s estimates of revenue prices for a given quarter.\nSince reserve prices are no longer applicable from the end of 2001, zero is used as a default to avoid rewriting the system.","description":"AUCTION_RP_ESTIMATE is public data, and is available to all\nparticipants.\n\nSource\n\nUpdates are quarterly by SRA team via SRIS interface.\n\nVolume\n\nThis view contains a maximum of 100 records per year.","primary_keys":["CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","QUARTER","VALUATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","is_integer":true,"num_int_bits":8},"VALUATIONID":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":true,"comment":"Identifier of the estimator"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data takes precedence","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record was changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RPESTIMATE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimate of reserve price","is_float":true}},"visibility":"Public","trigger":"Updated quarterly"},"AUCTION_TRANCHE":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_CONFIG","REPORT_SUB_TYPE":"AUCTION_TRANCHE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#55"],"comment":"AUCTION_TRANCHE supports the Settlement Residue Auction, by holding the default definitions for the percentage number of units allocated and dates applicable to each tranche for a specified auction quarter. This information provides the basis for setting up contracts for individual tranches.","description":"AUCTION_TRANCHE is public data, and is available to all participants.\n\nSource\n\nUpdates are quarterly from SRA team via SRIS interface.\n\nVolume\n\nAUCTION_TRANCHE contains a maximum of 100 records per year.","primary_keys":["CONTRACTYEAR","QUARTER","TRANCHE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","examples":["2032"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","examples":["4"],"is_integer":true,"num_int_bits":8},"TRANCHE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Label identifying the arbitrary segmented share of the Interconnector flow","examples":["1","12"],"is_integer":true,"num_int_bits":8},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data will take precedence","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUCTIONDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Default date of the auction","examples":["2029/12/17 00:00:00"],"parse_csv_as_string":true,"is_date":true},"CHANGEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date of changing this record","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"CHANGEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of person who changed this record","examples":["SYSTEM"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time record was last changed","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NOTIFYDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Default date participants notified of details","examples":["2029/12/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"UNITALLOCATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Percentage of units allocated to the tranche","examples":["8.33333333"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AUCTION_TRANCHE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":575,"decompressed_size_all_time":332270},"visibility":"Public","trigger":"Updated quarterly"},"AVERAGEPRICE30":{"package":"TRADING_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"AVERAGEPRICE30","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec61.htm#1"],"comment":"Reflects the 30-minute average price (the pre-5MS trading price).","primary_keys":["PERIODDATE","REGIONID"],"columns":{"PERIODDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"30-minute interval period, 1 to 48 from the start of the calendar day","examples":["2026/09/01 00:30:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:25:07"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The 30-minute interval period, 1 to 48","examples":["1","48"],"is_integer":true,"num_int_bits":16},"PRICE_CONFIDENCE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Result of Manifestly Incorrect Inputs Price Status and OCD_Status - either \"FIRM\" or \"NOT FIRM\". Only FIRM if the Dispatch Interval is resolved for both MII and OCD","examples":["FIRM"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this period","examples":["-0.02","0.01","0","162"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23AVERAGEPRICE30%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":62607,"decompressed_size_all_time":16618270},"visibility":"Public","trigger":"Every 30 minutes on price update"},"BANK_GUARANTEE":{"package":"PRUDENTIALS","pdr_config":{"mappings":[{"REPORT_NAME":"PRUDENTIAL","REPORT_SUB_TYPE":"BANK_GUARANTEE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec69.htm#1"],"comment":"Indicates the amount of bank guarantee the Company has with AEMO","primary_keys":["GUARANTEE_ID"],"columns":{"GUARANTEE_ID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The Bank Guarantee ID"},"COMMENCEMENT_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date AEMO received the bank guarantee details","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"COMPANY_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Company ID owning the Bank Guarantee"},"CREDIT_PROVIDER":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Bank Guarantee Provider Id"},"GUARANTEE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Dollar Amount of the bank guarantee","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant Id belonging to the company (Even though BG belongs to a Company, Participant Id is also added as all reports are published to the Participants)","is_categorical":true},"RETURN_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of Return","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TERMINATION_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of Termination","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On change"},"BIDDAYOFFER":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDDAYOFFER","VERSION":1},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDDAYOFFER","VERSION":2},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"BIDDAYOFFER","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"BIDDAYOFFER","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#1"],"comment":"BIDDAYOFFER shows the Energy and Ancillary Service bid data for each Market Day. BIDDAYOFFER is the parent table to BIDOFFERPERIOD. BIDDAYOFFER is a child table to BIDOFFERFILETRK","description":"The ancillary service arrangements require availability and prices for\neach Frequency Control Ancillary Service to be bid on a similar basis to\nenergy. Three tables (BIDOFFERFILETRK, BIDDAYOFFER and BIDOFFERPERIOD)\nfacilitate ancillary service bidding and include energy bidding.\n\nBIDDAYOFFER data is confidential to the submitting participant until\nmade public after 4am the next day.\n\nSource\n\nBIDDAYOFFER updates as ancillary service bids are processed. BIDDAYOFFER\nincludes all accepted energy and ancillary service bids.\n\nVolume\n\nApproximately 1,500,000 records per year","primary_keys":["BIDTYPE","DIRECTION","DUID","OFFERDATE","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DIRECTION":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"GEN\", \"LOAD\", \"BIDIRECTIONAL\"])","mandatory":false,"comment":"The power flow direction to which this offer applies: GEN, LOAD or BIDIRECTIONAL","examples":null,"warnings":["Despite AEMO's documentation saying that this column is mandatory, it is missing from older files. It was added to the schema in [version 5.3](https://tech-specs.docs.public.aemo.com.au/Content/TSP_EMMSDM53_April2024/Participant_Impact.htm#NEXTDAYbids).-"],"enums":["GEN","LOAD","BIDIRECTIONAL"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","examples":["2026/06/11 14:58:30.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date for applying the bid","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DAILYENERGYCONSTRAINT":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum energy available from Energy Constrained Plant. (Energy Bids Only)","examples":["500","3627"],"is_float":true},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"DAILY\", \"REBID\", \"DEFAULT\"])","mandatory":false,"comment":"Daily if processed before BidCutOff of previous day, otherwise REBID","examples":null,"warnings":["AEMO says this field may take a value of `Daily`, but it actually is `DAILY`.","Despite AEMO's description, this field may occasionally take on a third value, `DEFAULT` for [RERT](https://www.aemo.com.au/energy-systems/electricity/emergency-management/reliability-and-emergency-reserve-trader-rert) (e.g. with virtual `DUID`=`RT_NSW1`, participant `NEMRESTR` and explanation \"Initial Reserve Trader Default Bid\").\n"],"enums":["DAILY","REBID","DEFAULT"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/06/11 14:58:30"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUMLOAD":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Minimum MW load fast start plant","examples":["0","2","25"],"is_integer":true,"num_int_bits":128},"MR_FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Mandatory Restriction Offer Factor","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","examples":["ALDOGASF","ALNTARES","ALNTBHWF","ARARATWF","BALBESS","BANGOWF2","BBPEM","BOULBESS","BWFTRUST","CLEANCO","EEQGEN","HALLETT","HYDROTAS","SAWCML","SNOWY","SOUTHHYD","TIPSCO"],"is_categorical":true},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","examples":["-839.5","-898","-1034.61","-1000"],"is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","examples":["-5.72","0.06","0","174.16"],"is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","examples":["-70.35","0.06","0","276.22"],"is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","examples":["-5.16","9.01","-60","145"],"is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","examples":["-1.88","24.21","-43","235"],"is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","examples":["-6.21","36.75","0","274"],"is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","examples":["-1.68","66.64","0","374"],"is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","examples":["-0.09","3.36","224","998"],"is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","examples":["-2.64","97.64","349","22750"],"is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","examples":["1172.18","500","24002.79","23200"],"is_float":true},"REBID_AWARE_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. The time at which the participant became aware of the event(s) / occurrence(s) that prompted the rebid.Not validated by AEMO","examples":["01:00:04","01:41:01","05:25:00","07:25:00","09:17:05","09:17:15","10:32:34","10:51:06","10:57:00","10:57:24","11:08:03","11:09:00","11:20:45","11:21:39","11:35:28","12:27:00","12:35:00","12:39:00","13:38:00","14:04:00","14:05:00","14:11:00","14:51:18","14:58:28","15:51:08","17:00:00","20:35:00","21:51:00","22:16:00"]},"REBID_CATEGORY":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Enum([\"A\", \"P\", \"F\", \"E\", \"Z\", \"I\"])","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. A provided rebid category. Not validated by AEMO","examples":null,"warnings":["AEMO does not enforce compliance with the bidding rules. One in every few million rows has a lowercase value here. You should coerce to uppercast before casting to enum or querying.\n"],"coerce_to_uppercase":true,"enums":["A","P","F","E","Z","I"]},"REBID_DECISION_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. The time at which the participant made the decision to rebid. Not validated by AEMO","examples":["01:00:04","01:41:01","05:25:00","07:25:00","09:17:05","09:17:15","10:32:34","10:51:06","10:57:00","10:57:24","11:08:03","11:09:00","11:20:45","11:21:39","11:35:28","12:27:00","12:39:00","12:41:00","13:38:00","14:04:00","14:11:00","14:15:00","14:51:18","14:58:28","15:51:08","17:00:00","20:38:00","21:51:00","22:16:00"]},"REBID_EVENT_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The time of the event(s) or other occurrence(s) cited/adduced as the reason for the rebid. Required for rebids, not required for fixed load or low ramp rates. Expected in the format: HH:MM:SS e.g. 20:11:00","examples":["00:01:28","00:04:00","00:05:25","00:06:30","00:11:31","00:16:32","00:21:29","00:26:29","00:31:30","00:34:00","00:36:28","00:39:00","00:41:33","00:46:36","00:51:31","00:56:32","01:00:04","01:01:29","01:04:00","01:06:32","01:11:32","01:16:31","01:21:30","01:26:30","01:31:28","01:34:00","01:36:30","01:41:01","01:41:31","01:46:28","01:51:30","01:56:28","02:01:29","02:04:00","02:06:30","02:09:00","02:11:32","02:16:30","02:21:33","02:26:33","02:31:32","02:34:00","02:36:30","02:41:31","02:46:31","02:51:30","02:56:30","03:01:30","03:04:00","03:06:29","03:11:30","03:16:30","03:21:30","03:26:29","03:31:28","03:34:00","03:36:30","03:39:00","03:41:31","03:46:27","03:51:27","03:56:30","03:59:35","04:01:28","04:02:59","04:04:00","04:06:31","04:11:33","04:16:31","04:18:27","04:21:30","04:26:29","04:31:31","04:34:00","04:36:31","04:41:32","04:46:31","04:48:59","04:51:30","04:56:30","05:01:30","05:04:00","05:06:30","05:11:31","05:16:32","05:18:17","05:21:28","05:25:00","05:26:30","05:31:29","05:34:00","05:36:30","05:41:29","05:46:32","05:48:52","05:51:31","05:53:51","05:56:29","06:01:30","06:04:00","06:06:30","06:11:30","06:16:31","06:18:46","06:21:27","06:26:28","06:31:29","06:34:00","06:36:28","06:41:31","06:46:32","06:48:41","06:51:29","06:56:29","07:01:28","07:04:00","07:04:11","07:06:30","07:11:32","07:16:31","07:18:51","07:21:29","07:25:00","07:26:29","07:29:00","07:30:00","07:31:10","07:31:31","07:33:47","07:34:00","07:36:31","07:41:30","07:44:00","07:46:31","07:48:38","07:49:00","07:51:30","07:54:00","07:56:31","07:59:00","08:01:16","08:01:29","08:03:00","08:06:30","08:09:00","08:11:31","08:14:00","08:16:00","08:16:31","08:19:00","08:21:30","08:24:00","08:26:30","08:29:00","08:31:31","08:34:00","08:36:31","08:38:00","08:38:54","08:41:29","08:43:00","08:46:31","08:48:00","08:51:30","08:56:31","09:00:01","09:01:28","09:04:00","09:05:00","09:06:29","09:09:00","09:11:32","09:16:29","09:17:05","09:17:15","09:21:29","09:25:00","09:26:31","09:31:28","09:34:00","09:35:00","09:36:29","09:41:19","09:41:31","09:46:31","09:47:10","09:50:00","09:51:30","09:56:30","10:00:00","10:01:31","10:04:00","10:06:30","10:11:31","10:15:00","10:16:34","10:21:45","10:26:52","10:31:48","10:32:34","10:36:53","10:41:51","10:46:45","10:51:06","10:51:43","10:53:55","10:54:00","10:54:54","10:56:43","10:57:00","10:57:24","10:59:43","11:01:43","11:06:49","11:08:03","11:09:00","11:10:12","11:11:48","11:12:10","11:16:41","11:18:33","11:20:45","11:21:39","11:21:46","11:26:17","11:26:43","11:30:00","11:31:45","11:33:00","11:35:28","11:36:43","11:36:47","11:41:32","11:41:48","11:46:43","11:51:38","11:54:00","11:56:47","12:01:41","12:06:43","12:07:53","12:09:34","12:10:00","12:11:51","12:15:00","12:16:42","12:20:00","12:21:34","12:22:40","12:26:44","12:27:00","12:30:00","12:31:43","12:32:00","12:32:52","12:34:00","12:36:31","12:36:39","12:37:07","12:41:35","12:42:48","12:46:42","12:47:07","12:51:33","12:52:54","12:56:32","12:57:59","13:01:36","13:03:02","13:06:44","13:08:01","13:09:00","13:10:00","13:11:42","13:13:03","13:16:34","13:18:05","13:21:34","13:22:54","13:25:00","13:26:41","13:27:50","13:31:37","13:33:14","13:34:00","13:36:33","13:37:57","13:38:00","13:39:23","13:41:30","13:42:52","13:46:41","13:47:54","13:51:41","13:53:03","13:56:39","13:57:46","14:00:00","14:01:29","14:03:04","14:05:00","14:06:32","14:07:18","14:07:20","14:09:00","14:11:28","14:12:24","14:13:00","14:16:45","14:17:23","14:21:47","14:22:31","14:26:31","14:28:12","14:31:31","14:33:06","14:34:00","14:35:00","14:35:25","14:36:31","14:38:00","14:40:00","14:41:36","14:46:45","14:51:18","14:51:40","14:56:31","14:58:28","14:59:00","15:01:32","15:04:00","15:06:32","15:11:31","15:16:46","15:20:00","15:21:42","15:24:00","15:24:20","15:26:31","15:29:00","15:31:31","15:34:00","15:36:41","15:38:19","15:41:30","15:46:34","15:51:08","15:51:40","15:56:25","15:56:39","16:01:30","16:04:00","16:04:40","16:06:31","16:11:33","16:15:00","16:15:25","16:16:31","16:21:28","16:26:29","16:31:43","16:34:00","16:36:09","16:36:40","16:41:30","16:46:34","16:51:29","16:56:29","17:00:00","17:01:30","17:04:00","17:06:28","17:11:33","17:16:39","17:21:32","17:25:00","17:26:31","17:31:29","17:34:00","17:35:25","17:36:28","17:41:28","17:46:30","17:49:00","17:51:29","17:55:00","17:56:13","17:56:27","18:00:55","18:01:43","18:04:00","18:06:38","18:11:30","18:16:31","18:18:15","18:21:30","18:24:00","18:26:31","18:31:31","18:34:00","18:36:29","18:41:31","18:46:30","18:51:40","18:56:43","19:01:33","19:02:00","19:04:00","19:06:32","19:09:00","19:11:34","19:14:00","19:16:30","19:18:55","19:19:00","19:21:31","19:24:00","19:26:29","19:29:00","19:31:30","19:34:00","19:36:31","19:39:00","19:41:29","19:44:00","19:46:30","19:49:00","19:51:32","19:54:00","19:56:31","19:59:00","20:01:31","20:04:00","20:06:32","20:09:00","20:10:00","20:11:30","20:14:00","20:16:32","20:21:29","20:25:50","20:26:30","20:31:28","20:34:00","20:35:00","20:36:30","20:41:31","20:42:35","20:46:29","20:51:31","20:56:31","21:01:32","21:04:00","21:06:34","21:11:32","21:16:33","21:21:29","21:26:29","21:31:30","21:34:00","21:36:30","21:41:30","21:45:00","21:46:29","21:51:00","21:51:35","21:56:28","22:01:32","22:04:00","22:06:33","22:11:34","22:16:00","22:16:34","22:21:31","22:26:28","22:31:29","22:34:00","22:36:31","22:41:28","22:46:29","22:51:30","22:56:30","23:01:28","23:04:00","23:06:31","23:11:30","23:16:32","23:21:32","23:26:33","23:31:33","23:33:00","23:34:00","23:36:32","23:41:32","23:46:32","23:51:29","23:56:30"]},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(500)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities","examples":["00 Initial Bid","010 Unexpected/plant limits~Transformer limits","01:00~A~Initial Bid~OPT_Partial_R24","01:41~A~Initial Bid~OPT_Partial_R24","020 Reduction in avail cap~201 turbo wash engine #9","020 Reduction in avail cap~203 plant failure","020 Reduction in avail cap~outage eng 2","050 Chg in AEMO PD~54 PD price increase SA $28 02:30","095 Unit triggered by market~095 Avoid unecconomical start / stop","10:57~F~00 Initial Bid","12:32~F~001 Primary Response to D+1 Predispatch","A Change in AEMO Constraint Forecast Q>PWSP_PWSP_WOSP Actual MV @07:25 = -52.56 vs P5MIN forecast @07:20 = 0 SL","AVAILABILITY ADJ DUE TO OUTAGE SL","AVAILABILITY ADJ DUE TO OUTAGE UPDATE SL","Adj FSIP due to plant operational requirements SL","Adj avail - GT2-1 hydraulic pumps works. SL","Adj avail - GT3-2 hydraulic pump works. SL","Adj bands - VIC RRP changed for HHE 1800, was $31 @ 1500 vs $20 @ 1530. SL","Adj bands - soc management. SL","Adj pasa, recall - GT1-3 outage postponed. SL","Avail adj due to SOC condition SL","CHANGE IN NSW RRP FORECAST SL","Change in forecast SOC","Change in outage schedule: Trevallyn 1&2 condition monitoring runs","Constraint impact different from expected: V_T_NIL_FCSPS, Reduction in TAS demand forecast.","Constriant impact different from expected:  T_ROCOF_3_3, increase in P30 VIC price forecast.","Correcting error in previous bid. TUNGATIN. SL","Default Offer","Delay in RTS: BASTYAN.","Demand different from forecast: TAS SL","Early RTS - Bastyan SL","Early RTS: BASTYAN.","FCAS availability different from forecast: TAS R6 p5 sl","INITIAL BID","INITIAL OFFER","INITIAL OFFER SL","Initial Bid","Initial Offer","Initial Response to PD - SL","Initial offer","Lake level different from forecast - LI_WY_CA","NSW PRICE FORECAST CHANGED SL","Plant capability different to expectation: Bastyan OOS - SL","Plant failure: BASTYAN battery earth fault indication.","Plant failure: BASTYAN unit trip.","Price < forecast: VIC P5min and P30.","Price < forecast: VIC P5min, Basslink flow different from forecast.","Price < forecast: VIC. PD SL","Price > forecast: VIC P5min and P30.","Price > forecast: VIC P5min, SL","Price > forecast: VIC. PD. SL","Price different from forecast: VIC P30 - SL","SA1 energy 30PD@2026-09-01 07:40:00 AEST for 2026-09-01 10:05:00 AEST is -36.10 vs 30PD@2026-09-01 07:35:00 AEST for 2026-09-01 10:05:00 AEST is -20.76","SA1 energy 30PD@2026-09-01 08:10:00 AEST for 2026-09-01 10:00:00 AEST is -35.79 vs 30PD@2026-09-01 08:05:00 AEST for 2026-09-01 10:00:00 AEST is -20.00","SA1 energy 30PD@2026-09-01 08:40:00 AEST for 2026-09-01 10:00:00 AEST is -20.00 vs 30PD@2026-09-01 08:35:00 AEST for 2026-09-01 10:00:00 AEST is -35.79","SA1 energy 30PD@2026-09-01 23:40:00 AEST for 2026-09-02 02:05:00 AEST is 98.00 vs 30PD@2026-09-01 23:35:00 AEST for 2026-09-02 02:05:00 AEST is 35.13","SA1 energy 5PD@2026-09-01 08:45:00 AEST for 2026-09-01 09:25:00 AEST is -49.40 vs 5PD@2026-09-01 08:40:00 AEST for 2026-09-01 09:25:00 AEST is -25.16","SA1 energy 5PD@2026-09-01 08:50:00 AEST for 2026-09-01 09:25:00 AEST is -18.55 vs 5PD@2026-09-01 08:45:00 AEST for 2026-09-01 09:25:00 AEST is -49.40","SA1 energy 5PD@2026-09-01 10:45:00 AEST for 2026-09-01 11:35:00 AEST is -7.25 vs 5PD@2026-09-01 10:40:00 AEST for 2026-09-01 11:35:00 AEST is -67.06","SA1 energy 5PD@2026-09-01 10:50:00 AEST for 2026-09-01 11:40:00 AEST is -7.15 vs 5PD@2026-09-01 10:45:00 AEST for 2026-09-01 11:40:00 AEST is -67.06","SA1 energy 5PD@2026-09-01 10:55:00 AEST for 2026-09-01 11:45:00 AEST is -8.00 vs 5PD@2026-09-01 10:50:00 AEST for 2026-09-01 11:45:00 AEST is -67.06","SA1 energy 5PD@2026-09-01 11:00:00 AEST for 2026-09-01 11:50:00 AEST is -8.00 vs 5PD@2026-09-01 10:55:00 AEST for 2026-09-01 11:50:00 AEST is -67.06","SA1 energy 5PD@2026-09-01 11:05:00 AEST for 2026-09-01 11:55:00 AEST is -8.00 vs 5PD@2026-09-01 11:00:00 AEST for 2026-09-01 11:55:00 AEST is -67.06","SA1 energy 5PD@2026-09-01 12:00:00 AEST for 2026-09-01 12:20:00 AEST is -8.00 vs 5PD@2026-09-01 11:55:00 AEST for 2026-09-01 12:20:00 AEST is -18.55","SA1 energy 5PD@2026-09-01 12:25:00 AEST for 2026-09-01 12:30:00 AEST is -36.77 vs 5PD@2026-09-01 12:20:00 AEST for 2026-09-01 12:30:00 AEST is -20.00","SA1 energy 5PD@2026-09-01 12:40:00 AEST for 2026-09-01 12:55:00 AEST is -60.61 vs 5PD@2026-09-01 12:35:00 AEST for 2026-09-01 12:55:00 AEST is -21.57","SA1 energy 5PD@2026-09-01 12:50:00 AEST for 2026-09-01 13:10:00 AEST is -20.00 vs 5PD@2026-09-01 12:45:00 AEST for 2026-09-01 13:10:00 AEST is -35.74","SA1 energy 5PD@2026-09-01 12:55:00 AEST for 2026-09-01 13:00:00 AEST is -18.88 vs 5PD@2026-09-01 12:50:00 AEST for 2026-09-01 13:00:00 AEST is -46.79","SA1 energy 5PD@2026-09-01 13:10:00 AEST for 2026-09-01 13:30:00 AEST is -8.00 vs 5PD@2026-09-01 13:05:00 AEST for 2026-09-01 13:30:00 AEST is -18.55","SA1 energy 5PD@2026-09-01 15:35:00 AEST for 2026-09-01 15:40:00 AEST is 7.96 vs 5PD@2026-09-01 15:30:00 AEST for 2026-09-01 15:40:00 AEST is -1.02","SA1 energy 5PD@2026-09-01 15:40:00 AEST for 2026-09-01 15:45:00 AEST is -1.02 vs 5PD@2026-09-01 15:35:00 AEST for 2026-09-01 15:45:00 AEST is 10.65","SA1 energy 5PD@2026-09-01 15:55:00 AEST for 2026-09-01 16:05:00 AEST is 11.06 vs 5PD@2026-09-01 15:50:00 AEST for 2026-09-01 16:05:00 AEST is -1.00","SA1 energy 5PD@2026-09-01 16:00:00 AEST for 2026-09-01 16:05:00 AEST is -4.21 vs 5PD@2026-09-01 15:55:00 AEST for 2026-09-01 16:05:00 AEST is 11.06","SA1 energy 5PD@2026-09-01 16:10:00 AEST for 2026-09-01 16:15:00 AEST is 9.10 vs 5PD@2026-09-01 16:05:00 AEST for 2026-09-01 16:15:00 AEST is -1.02","SA1 energy 5PD@2026-09-01 16:30:00 AEST for 2026-09-01 16:50:00 AEST is 0.02 vs 5PD@2026-09-01 16:25:00 AEST for 2026-09-01 16:50:00 AEST is -6.25","SA1 energy 5PD@2026-09-01 16:35:00 AEST for 2026-09-01 17:00:00 AEST is 101.96 vs 5PD@2026-09-01 16:30:00 AEST for 2026-09-01 17:00:00 AEST is 15.99","SA1 energy 5PD@2026-09-01 16:40:00 AEST for 2026-09-01 16:45:00 AEST is 22.20 vs 5PD@2026-09-01 16:35:00 AEST for 2026-09-01 16:45:00 AEST is -1.02","SA1 energy 5PD@2026-09-01 16:45:00 AEST for 2026-09-01 17:00:00 AEST is 40.07 vs 5PD@2026-09-01 16:40:00 AEST for 2026-09-01 17:00:00 AEST is 130.00","SA1 energy 5PD@2026-09-01 16:55:00 AEST for 2026-09-01 17:00:00 AEST is 12.97 vs 5PD@2026-09-01 16:50:00 AEST for 2026-09-01 17:00:00 AEST is 38.07","SA1 energy 5PD@2026-09-01 17:00:00 AEST for 2026-09-01 17:25:00 AEST is 84.51 vs 5PD@2026-09-01 16:55:00 AEST for 2026-09-01 17:25:00 AEST is 130.55","SA1 energy 5PD@2026-09-01 17:05:00 AEST for 2026-09-01 17:25:00 AEST is 49.03 vs 5PD@2026-09-01 17:00:00 AEST for 2026-09-01 17:25:00 AEST is 84.51","SA1 energy 5PD@2026-09-01 17:10:00 AEST for 2026-09-01 17:35:00 AEST is 138.00 vs 5PD@2026-09-01 17:05:00 AEST for 2026-09-01 17:35:00 AEST is 84.51","SA1 energy 5PD@2026-09-01 17:15:00 AEST for 2026-09-01 17:35:00 AEST is 59.79 vs 5PD@2026-09-01 17:10:00 AEST for 2026-09-01 17:35:00 AEST is 138.00","SA1 energy 5PD@2026-09-01 17:35:00 AEST for 2026-09-01 17:40:00 AEST is 46.17 vs 5PD@2026-09-01 17:30:00 AEST for 2026-09-01 17:40:00 AEST is 130.00","SA1 energy 5PD@2026-09-01 18:50:00 AEST for 2026-09-01 19:00:00 AEST is 101.02 vs 5PD@2026-09-01 18:45:00 AEST for 2026-09-01 19:00:00 AEST is 84.51","SA1 energy 5PD@2026-09-01 19:00:00 AEST for 2026-09-01 19:10:00 AEST is 55.90 vs 5PD@2026-09-01 18:55:00 AEST for 2026-09-01 19:10:00 AEST is 101.02","SA1 energy 5PD@2026-09-01 20:20:00 AEST for 2026-09-01 20:25:00 AEST is 84.51 vs 5PD@2026-09-01 20:15:00 AEST for 2026-09-01 20:25:00 AEST is 46.92","SA1 energy 5PD@2026-09-01 20:25:00 AEST for 2026-09-01 20:30:00 AEST is 76.56 vs 5PD@2026-09-01 20:20:00 AEST for 2026-09-01 20:30:00 AEST is 84.51","SA1 energy 5PD@2026-09-01 20:35:00 AEST for 2026-09-01 21:00:00 AEST is 44.16 vs 5PD@2026-09-01 20:30:00 AEST for 2026-09-01 21:00:00 AEST is 84.51","SA1 energy 5PD@2026-09-01 20:50:00 AEST for 2026-09-01 21:30:00 AEST is 77.04 vs 5PD@2026-09-01 20:45:00 AEST for 2026-09-01 21:30:00 AEST is 84.51","SA1 energy 5PD@2026-09-02 00:15:00 AEST for 2026-09-02 00:20:00 AEST is 101.02 vs 5PD@2026-09-02 00:10:00 AEST for 2026-09-02 00:20:00 AEST is 37.51","SA1 energy 5PD@2026-09-02 00:20:00 AEST for 2026-09-02 00:25:00 AEST is 101.02 vs 5PD@2026-09-02 00:15:00 AEST for 2026-09-02 00:25:00 AEST is 69.41","SA1 energy 5PD@2026-09-02 00:25:00 AEST for 2026-09-02 00:30:00 AEST is 101.02 vs 5PD@2026-09-02 00:20:00 AEST for 2026-09-02 00:30:00 AEST is 69.41","SA1 energy 5PD@2026-09-02 00:30:00 AEST for 2026-09-02 00:35:00 AEST is 101.02 vs 5PD@2026-09-02 00:25:00 AEST for 2026-09-02 00:35:00 AEST is 91.25","SA1 energy 5PD@2026-09-02 00:35:00 AEST for 2026-09-02 00:50:00 AEST is 69.41 vs 5PD@2026-09-02 00:30:00 AEST for 2026-09-02 00:50:00 AEST is 84.51","SA1 energy 5PD@2026-09-02 00:40:00 AEST for 2026-09-02 00:45:00 AEST is 105.08 vs 5PD@2026-09-02 00:35:00 AEST for 2026-09-02 00:45:00 AEST is 84.51","SA1 energy 5PD@2026-09-02 00:45:00 AEST for 2026-09-02 00:50:00 AEST is 84.51 vs 5PD@2026-09-02 00:40:00 AEST for 2026-09-02 00:50:00 AEST is 104.66","SA1 energy 5PD@2026-09-02 00:50:00 AEST for 2026-09-02 00:55:00 AEST is 101.02 vs 5PD@2026-09-02 00:45:00 AEST for 2026-09-02 00:55:00 AEST is 84.51","SA1 energy 5PD@2026-09-02 00:55:00 AEST for 2026-09-02 01:05:00 AEST is 84.51 vs 5PD@2026-09-02 00:50:00 AEST for 2026-09-02 01:05:00 AEST is 101.02","SA1 energy 5PD@2026-09-02 01:05:00 AEST for 2026-09-02 01:10:00 AEST is 69.41 vs 5PD@2026-09-02 01:00:00 AEST for 2026-09-02 01:10:00 AEST is 88.88","SA1 energy 5PD@2026-09-02 01:10:00 AEST for 2026-09-02 01:20:00 AEST is 91.25 vs 5PD@2026-09-02 01:05:00 AEST for 2026-09-02 01:20:00 AEST is 98.00","SA1 energy 5PD@2026-09-02 01:20:00 AEST for 2026-09-02 01:50:00 AEST is 101.02 vs 5PD@2026-09-02 01:15:00 AEST for 2026-09-02 01:50:00 AEST is 88.88","SA1 energy 5PD@2026-09-02 01:35:00 AEST for 2026-09-02 01:40:00 AEST is 101.02 vs 5PD@2026-09-02 01:30:00 AEST for 2026-09-02 01:40:00 AEST is 61.00","SA1 energy 5PD@2026-09-02 01:55:00 AEST for 2026-09-02 02:20:00 AEST is 101.02 vs 5PD@2026-09-02 01:50:00 AEST for 2026-09-02 02:20:00 AEST is 59.27","SA1 energy 5PD@2026-09-02 02:00:00 AEST for 2026-09-02 02:05:00 AEST is 55.90 vs 5PD@2026-09-02 01:55:00 AEST for 2026-09-02 02:05:00 AEST is 101.02","SA1 energy 5PD@2026-09-02 02:05:00 AEST for 2026-09-02 02:10:00 AEST is 101.02 vs 5PD@2026-09-02 02:00:00 AEST for 2026-09-02 02:10:00 AEST is 55.55","SA1 energy 5PD@2026-09-02 02:10:00 AEST for 2026-09-02 02:15:00 AEST is 101.02 vs 5PD@2026-09-02 02:05:00 AEST for 2026-09-02 02:15:00 AEST is 55.56","SA1 energy 5PD@2026-09-02 02:15:00 AEST for 2026-09-02 02:20:00 AEST is 52.76 vs 5PD@2026-09-02 02:10:00 AEST for 2026-09-02 02:20:00 AEST is 101.02","SA1 energy 5PD@2026-09-02 02:20:00 AEST for 2026-09-02 02:25:00 AEST is 88.85 vs 5PD@2026-09-02 02:15:00 AEST for 2026-09-02 02:25:00 AEST is 48.43","SA1 energy 5PD@2026-09-02 02:25:00 AEST for 2026-09-02 02:30:00 AEST is 49.69 vs 5PD@2026-09-02 02:20:00 AEST for 2026-09-02 02:30:00 AEST is 88.06","SA1 energy 5PD@2026-09-02 02:35:00 AEST for 2026-09-02 02:40:00 AEST is 56.06 vs 5PD@2026-09-02 02:30:00 AEST for 2026-09-02 02:40:00 AEST is 49.50","SA1 energy 5PD@2026-09-02 02:40:00 AEST for 2026-09-02 02:45:00 AEST is 88.88 vs 5PD@2026-09-02 02:35:00 AEST for 2026-09-02 02:45:00 AEST is 55.64","SA1 energy 5PD@2026-09-02 02:45:00 AEST for 2026-09-02 03:00:00 AEST is 101.02 vs 5PD@2026-09-02 02:40:00 AEST for 2026-09-02 03:00:00 AEST is 52.31","SA1 energy 5PD@2026-09-02 03:00:00 AEST for 2026-09-02 03:05:00 AEST is 68.87 vs 5PD@2026-09-02 02:55:00 AEST for 2026-09-02 03:05:00 AEST is 88.88","SA1 energy 5PD@2026-09-02 03:05:00 AEST for 2026-09-02 03:10:00 AEST is 57.46 vs 5PD@2026-09-02 03:00:00 AEST for 2026-09-02 03:10:00 AEST is 50.62","SA1 energy 5PD@2026-09-02 03:10:00 AEST for 2026-09-02 03:15:00 AEST is 65.16 vs 5PD@2026-09-02 03:05:00 AEST for 2026-09-02 03:15:00 AEST is 55.90","SA1 energy 5PD@2026-09-02 03:15:00 AEST for 2026-09-02 03:20:00 AEST is 57.06 vs 5PD@2026-09-02 03:10:00 AEST for 2026-09-02 03:20:00 AEST is 63.57","SA1 energy 5PD@2026-09-02 03:45:00 AEST for 2026-09-02 03:50:00 AEST is 65.87 vs 5PD@2026-09-02 03:40:00 AEST for 2026-09-02 03:50:00 AEST is 60.31","SA1 lower_5min 5PD@2026-09-01 13:45:00 AEST for 2026-09-01 14:00:00 AEST is 0.03 vs 5PD@2026-09-01 13:40:00 AEST for 2026-09-01 14:00:00 AEST is 0.09","SA1 lower_5min 5PD@2026-09-01 14:00:00 AEST for 2026-09-01 14:05:00 AEST is 0.10 vs 5PD@2026-09-01 13:55:00 AEST for 2026-09-01 14:05:00 AEST is 0.01","SA1 lower_5min 5PD@2026-09-01 14:40:00 AEST for 2026-09-01 14:45:00 AEST is 0.01 vs 5PD@2026-09-01 14:35:00 AEST for 2026-09-01 14:45:00 AEST is 0.30","SA1 lower_60sec 30PD@2026-09-01 06:40:00 AEST for 2026-09-01 10:35:00 AEST is 0.20 vs 30PD@2026-09-01 06:35:00 AEST for 2026-09-01 10:35:00 AEST is 0.01","SA1 lower_60sec 30PD@2026-09-01 07:10:00 AEST for 2026-09-01 12:05:00 AEST is 0.38 vs 30PD@2026-09-01 07:05:00 AEST for 2026-09-01 12:05:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 09:10:00 AEST for 2026-09-01 10:05:00 AEST is 0.09 vs 5PD@2026-09-01 09:05:00 AEST for 2026-09-01 10:05:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 10:10:00 AEST for 2026-09-01 10:50:00 AEST is 0.20 vs 5PD@2026-09-01 10:05:00 AEST for 2026-09-01 10:50:00 AEST is 0.07","SA1 lower_60sec 5PD@2026-09-01 10:15:00 AEST for 2026-09-01 11:05:00 AEST is 0.07 vs 5PD@2026-09-01 10:10:00 AEST for 2026-09-01 11:05:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 10:20:00 AEST for 2026-09-01 11:10:00 AEST is 0.09 vs 5PD@2026-09-01 10:15:00 AEST for 2026-09-01 11:10:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 10:30:00 AEST for 2026-09-01 10:55:00 AEST is 1.05 vs 5PD@2026-09-01 10:25:00 AEST for 2026-09-01 10:55:00 AEST is 0.10","SA1 lower_60sec 5PD@2026-09-01 10:35:00 AEST for 2026-09-01 10:55:00 AEST is 0.20 vs 5PD@2026-09-01 10:30:00 AEST for 2026-09-01 10:55:00 AEST is 1.05","SA1 lower_60sec 5PD@2026-09-01 11:10:00 AEST for 2026-09-01 11:15:00 AEST is 0.01 vs 5PD@2026-09-01 11:05:00 AEST for 2026-09-01 11:15:00 AEST is 0.07","SA1 lower_60sec 5PD@2026-09-01 11:30:00 AEST for 2026-09-01 11:35:00 AEST is 0.09 vs 5PD@2026-09-01 11:25:00 AEST for 2026-09-01 11:35:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 11:55:00 AEST for 2026-09-01 12:10:00 AEST is 0.20 vs 5PD@2026-09-01 11:50:00 AEST for 2026-09-01 12:10:00 AEST is 0.03","SA1 lower_60sec 5PD@2026-09-01 12:15:00 AEST for 2026-09-01 12:25:00 AEST is 0.07 vs 5PD@2026-09-01 12:10:00 AEST for 2026-09-01 12:25:00 AEST is 0.38","SA1 lower_60sec 5PD@2026-09-01 12:35:00 AEST for 2026-09-01 12:40:00 AEST is 0.25 vs 5PD@2026-09-01 12:30:00 AEST for 2026-09-01 12:40:00 AEST is 0.05","SA1 lower_60sec 5PD@2026-09-01 13:05:00 AEST for 2026-09-01 13:10:00 AEST is 0.38 vs 5PD@2026-09-01 13:00:00 AEST for 2026-09-01 13:10:00 AEST is 0.10","SA1 lower_60sec 5PD@2026-09-01 13:25:00 AEST for 2026-09-01 13:45:00 AEST is 1.30 vs 5PD@2026-09-01 13:20:00 AEST for 2026-09-01 13:45:00 AEST is 0.38","SA1 lower_60sec 5PD@2026-09-01 13:30:00 AEST for 2026-09-01 13:35:00 AEST is 0.08 vs 5PD@2026-09-01 13:25:00 AEST for 2026-09-01 13:35:00 AEST is 0.36","SA1 lower_60sec 5PD@2026-09-01 13:35:00 AEST for 2026-09-01 13:50:00 AEST is 0.36 vs 5PD@2026-09-01 13:30:00 AEST for 2026-09-01 13:50:00 AEST is 1.05","SA1 lower_60sec 5PD@2026-09-01 13:40:00 AEST for 2026-09-01 13:45:00 AEST is 0.10 vs 5PD@2026-09-01 13:35:00 AEST for 2026-09-01 13:45:00 AEST is 0.39","SA1 lower_60sec 5PD@2026-09-01 14:10:00 AEST for 2026-09-01 14:15:00 AEST is 0.69 vs 5PD@2026-09-01 14:05:00 AEST for 2026-09-01 14:15:00 AEST is 1.30","SA1 lower_60sec 5PD@2026-09-01 14:30:00 AEST for 2026-09-01 14:40:00 AEST is 0.09 vs 5PD@2026-09-01 14:25:00 AEST for 2026-09-01 14:40:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 14:35:00 AEST for 2026-09-01 14:40:00 AEST is 0.20 vs 5PD@2026-09-01 14:30:00 AEST for 2026-09-01 14:40:00 AEST is 0.09","SA1 lower_60sec 5PD@2026-09-01 14:45:00 AEST for 2026-09-01 14:55:00 AEST is 0.10 vs 5PD@2026-09-01 14:40:00 AEST for 2026-09-01 14:55:00 AEST is 0.36","SA1 lower_60sec 5PD@2026-09-01 14:50:00 AEST for 2026-09-01 15:00:00 AEST is 0.10 vs 5PD@2026-09-01 14:45:00 AEST for 2026-09-01 15:00:00 AEST is 0.20","SA1 lower_60sec 5PD@2026-09-01 22:00:00 AEST for 2026-09-01 22:20:00 AEST is 0.01 vs 5PD@2026-09-01 21:55:00 AEST for 2026-09-01 22:20:00 AEST is 0.07","SA1 lower_60sec 5PD@2026-09-01 22:05:00 AEST for 2026-09-01 22:45:00 AEST is 0.01 vs 5PD@2026-09-01 22:00:00 AEST for 2026-09-01 22:45:00 AEST is 0.10","SA1 lower_60sec 5PD@2026-09-01 22:10:00 AEST for 2026-09-01 22:40:00 AEST is 0.03 vs 5PD@2026-09-01 22:05:00 AEST for 2026-09-01 22:40:00 AEST is 0.09","SA1 lower_60sec 5PD@2026-09-01 23:05:00 AEST for 2026-09-01 23:40:00 AEST is 0.01 vs 5PD@2026-09-01 23:00:00 AEST for 2026-09-01 23:40:00 AEST is 0.10","SA1 lower_6sec 30PD@2026-09-01 09:40:00 AEST for 2026-09-01 12:30:00 AEST is 0.38 vs 30PD@2026-09-01 09:35:00 AEST for 2026-09-01 12:30:00 AEST is 0.01","SA1 lower_6sec 5PD@2026-09-01 14:15:00 AEST for 2026-09-01 14:30:00 AEST is 0.01 vs 5PD@2026-09-01 14:10:00 AEST for 2026-09-01 14:30:00 AEST is 0.10","SA1 lower_reg 5PD@2026-09-01 09:15:00 AEST for 2026-09-01 09:55:00 AEST is 2.00 vs 5PD@2026-09-01 09:10:00 AEST for 2026-09-01 09:55:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 09:55:00 AEST for 2026-09-01 10:40:00 AEST is 0.70 vs 5PD@2026-09-01 09:50:00 AEST for 2026-09-01 10:40:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 10:05:00 AEST for 2026-09-01 10:50:00 AEST is 9.63 vs 5PD@2026-09-01 10:00:00 AEST for 2026-09-01 10:50:00 AEST is 0.69","SA1 lower_reg 5PD@2026-09-01 10:25:00 AEST for 2026-09-01 11:15:00 AEST is 3.33 vs 5PD@2026-09-01 10:20:00 AEST for 2026-09-01 11:15:00 AEST is 6.48","SA1 lower_reg 5PD@2026-09-01 10:40:00 AEST for 2026-09-01 11:30:00 AEST is 3.33 vs 5PD@2026-09-01 10:35:00 AEST for 2026-09-01 11:30:00 AEST is 6.48","SA1 lower_reg 5PD@2026-09-01 11:15:00 AEST for 2026-09-01 11:30:00 AEST is 4.00 vs 5PD@2026-09-01 11:10:00 AEST for 2026-09-01 11:30:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 11:20:00 AEST for 2026-09-01 11:30:00 AEST is 2.00 vs 5PD@2026-09-01 11:15:00 AEST for 2026-09-01 11:30:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 11:25:00 AEST for 2026-09-01 11:55:00 AEST is 1.37 vs 5PD@2026-09-01 11:20:00 AEST for 2026-09-01 11:55:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 11:35:00 AEST for 2026-09-01 11:50:00 AEST is 4.00 vs 5PD@2026-09-01 11:30:00 AEST for 2026-09-01 11:50:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 11:40:00 AEST for 2026-09-01 12:00:00 AEST is 1.80 vs 5PD@2026-09-01 11:35:00 AEST for 2026-09-01 12:00:00 AEST is 1.27","SA1 lower_reg 5PD@2026-09-01 11:45:00 AEST for 2026-09-01 11:50:00 AEST is 1.80 vs 5PD@2026-09-01 11:40:00 AEST for 2026-09-01 11:50:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 11:50:00 AEST for 2026-09-01 11:55:00 AEST is 4.00 vs 5PD@2026-09-01 11:45:00 AEST for 2026-09-01 11:55:00 AEST is 1.80","SA1 lower_reg 5PD@2026-09-01 12:05:00 AEST for 2026-09-01 12:10:00 AEST is 1.99 vs 5PD@2026-09-01 12:00:00 AEST for 2026-09-01 12:10:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 12:10:00 AEST for 2026-09-01 12:15:00 AEST is 2.00 vs 5PD@2026-09-01 12:05:00 AEST for 2026-09-01 12:15:00 AEST is 2.09","SA1 lower_reg 5PD@2026-09-01 12:20:00 AEST for 2026-09-01 12:30:00 AEST is 2.00 vs 5PD@2026-09-01 12:15:00 AEST for 2026-09-01 12:30:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 12:30:00 AEST for 2026-09-01 12:35:00 AEST is 2.00 vs 5PD@2026-09-01 12:25:00 AEST for 2026-09-01 12:35:00 AEST is 1.50","SA1 lower_reg 5PD@2026-09-01 13:00:00 AEST for 2026-09-01 13:10:00 AEST is 1.37 vs 5PD@2026-09-01 12:55:00 AEST for 2026-09-01 13:10:00 AEST is 0.69","SA1 lower_reg 5PD@2026-09-01 13:15:00 AEST for 2026-09-01 13:55:00 AEST is 2.00 vs 5PD@2026-09-01 13:10:00 AEST for 2026-09-01 13:55:00 AEST is 0.99","SA1 lower_reg 5PD@2026-09-01 13:20:00 AEST for 2026-09-01 13:50:00 AEST is 1.00 vs 5PD@2026-09-01 13:15:00 AEST for 2026-09-01 13:50:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 13:50:00 AEST for 2026-09-01 13:55:00 AEST is 0.69 vs 5PD@2026-09-01 13:45:00 AEST for 2026-09-01 13:55:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 14:05:00 AEST for 2026-09-01 14:10:00 AEST is 0.99 vs 5PD@2026-09-01 14:00:00 AEST for 2026-09-01 14:10:00 AEST is 0.69","SA1 lower_reg 5PD@2026-09-01 14:20:00 AEST for 2026-09-01 15:10:00 AEST is 2.00 vs 5PD@2026-09-01 14:15:00 AEST for 2026-09-01 15:10:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 15:00:00 AEST for 2026-09-01 15:50:00 AEST is 2.00 vs 5PD@2026-09-01 14:55:00 AEST for 2026-09-01 15:50:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 15:05:00 AEST for 2026-09-01 15:10:00 AEST is 1.00 vs 5PD@2026-09-01 15:00:00 AEST for 2026-09-01 15:10:00 AEST is 1.37","SA1 lower_reg 5PD@2026-09-01 15:10:00 AEST for 2026-09-01 15:15:00 AEST is 1.00 vs 5PD@2026-09-01 15:05:00 AEST for 2026-09-01 15:15:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 15:15:00 AEST for 2026-09-01 15:20:00 AEST is 4.00 vs 5PD@2026-09-01 15:10:00 AEST for 2026-09-01 15:20:00 AEST is 1.37","SA1 lower_reg 5PD@2026-09-01 15:20:00 AEST for 2026-09-01 15:40:00 AEST is 0.88 vs 5PD@2026-09-01 15:15:00 AEST for 2026-09-01 15:40:00 AEST is 1.80","SA1 lower_reg 5PD@2026-09-01 15:25:00 AEST for 2026-09-01 15:30:00 AEST is 1.65 vs 5PD@2026-09-01 15:20:00 AEST for 2026-09-01 15:30:00 AEST is 1.59","SA1 lower_reg 5PD@2026-09-01 15:45:00 AEST for 2026-09-01 16:05:00 AEST is 4.00 vs 5PD@2026-09-01 15:40:00 AEST for 2026-09-01 16:05:00 AEST is 1.80","SA1 lower_reg 5PD@2026-09-01 15:50:00 AEST for 2026-09-01 16:25:00 AEST is 3.99 vs 5PD@2026-09-01 15:45:00 AEST for 2026-09-01 16:25:00 AEST is 3.33","SA1 lower_reg 5PD@2026-09-01 16:05:00 AEST for 2026-09-01 16:10:00 AEST is 1.37 vs 5PD@2026-09-01 16:00:00 AEST for 2026-09-01 16:10:00 AEST is 3.99","SA1 lower_reg 5PD@2026-09-01 16:15:00 AEST for 2026-09-01 16:20:00 AEST is 1.50 vs 5PD@2026-09-01 16:10:00 AEST for 2026-09-01 16:20:00 AEST is 1.65","SA1 lower_reg 5PD@2026-09-01 16:20:00 AEST for 2026-09-01 16:35:00 AEST is 2.18 vs 5PD@2026-09-01 16:15:00 AEST for 2026-09-01 16:35:00 AEST is 2.50","SA1 lower_reg 5PD@2026-09-01 16:25:00 AEST for 2026-09-01 16:50:00 AEST is 3.33 vs 5PD@2026-09-01 16:20:00 AEST for 2026-09-01 16:50:00 AEST is 4.00","SA1 lower_reg 5PD@2026-09-01 16:50:00 AEST for 2026-09-01 16:55:00 AEST is 0.88 vs 5PD@2026-09-01 16:45:00 AEST for 2026-09-01 16:55:00 AEST is 1.37","SA1 lower_reg 5PD@2026-09-01 21:20:00 AEST for 2026-09-01 21:35:00 AEST is 2.00 vs 5PD@2026-09-01 21:15:00 AEST for 2026-09-01 21:35:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 21:25:00 AEST for 2026-09-01 21:35:00 AEST is 0.37 vs 5PD@2026-09-01 21:20:00 AEST for 2026-09-01 21:35:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 21:30:00 AEST for 2026-09-01 22:05:00 AEST is 2.00 vs 5PD@2026-09-01 21:25:00 AEST for 2026-09-01 22:05:00 AEST is 3.39","SA1 lower_reg 5PD@2026-09-01 21:35:00 AEST for 2026-09-01 21:40:00 AEST is 3.99 vs 5PD@2026-09-01 21:30:00 AEST for 2026-09-01 21:40:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 21:40:00 AEST for 2026-09-01 22:05:00 AEST is 2.00 vs 5PD@2026-09-01 21:35:00 AEST for 2026-09-01 22:05:00 AEST is 1.00","SA1 lower_reg 5PD@2026-09-01 21:45:00 AEST for 2026-09-01 22:00:00 AEST is 0.71 vs 5PD@2026-09-01 21:40:00 AEST for 2026-09-01 22:00:00 AEST is 1.27","SA1 lower_reg 5PD@2026-09-01 21:50:00 AEST for 2026-09-01 22:00:00 AEST is 2.00 vs 5PD@2026-09-01 21:45:00 AEST for 2026-09-01 22:00:00 AEST is 0.71","SA1 lower_reg 5PD@2026-09-01 21:55:00 AEST for 2026-09-01 22:10:00 AEST is 1.37 vs 5PD@2026-09-01 21:50:00 AEST for 2026-09-01 22:10:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 22:15:00 AEST for 2026-09-01 22:35:00 AEST is 2.00 vs 5PD@2026-09-01 22:10:00 AEST for 2026-09-01 22:35:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 22:20:00 AEST for 2026-09-01 23:00:00 AEST is 0.88 vs 5PD@2026-09-01 22:15:00 AEST for 2026-09-01 23:00:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 22:25:00 AEST for 2026-09-01 23:05:00 AEST is 1.00 vs 5PD@2026-09-01 22:20:00 AEST for 2026-09-01 23:05:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 22:30:00 AEST for 2026-09-01 23:10:00 AEST is 0.37 vs 5PD@2026-09-01 22:25:00 AEST for 2026-09-01 23:10:00 AEST is 0.88","SA1 lower_reg 5PD@2026-09-01 22:35:00 AEST for 2026-09-01 22:50:00 AEST is 0.69 vs 5PD@2026-09-01 22:30:00 AEST for 2026-09-01 22:50:00 AEST is 1.00","SA1 lower_reg 5PD@2026-09-01 22:40:00 AEST for 2026-09-01 22:55:00 AEST is 2.00 vs 5PD@2026-09-01 22:35:00 AEST for 2026-09-01 22:55:00 AEST is 0.69","SA1 lower_reg 5PD@2026-09-01 22:45:00 AEST for 2026-09-01 22:50:00 AEST is 0.37 vs 5PD@2026-09-01 22:40:00 AEST for 2026-09-01 22:50:00 AEST is 0.69","SA1 lower_reg 5PD@2026-09-01 22:55:00 AEST for 2026-09-01 23:00:00 AEST is 0.69 vs 5PD@2026-09-01 22:50:00 AEST for 2026-09-01 23:00:00 AEST is 2.00","SA1 lower_reg 5PD@2026-09-01 23:10:00 AEST for 2026-09-01 23:55:00 AEST is 0.37 vs 5PD@2026-09-01 23:05:00 AEST for 2026-09-01 23:55:00 AEST is 1.00","SA1 lower_reg 5PD@2026-09-01 23:45:00 AEST for 2026-09-02 00:05:00 AEST is 0.72 vs 5PD@2026-09-01 23:40:00 AEST for 2026-09-02 00:05:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-01 23:50:00 AEST for 2026-09-02 00:00:00 AEST is 0.37 vs 5PD@2026-09-01 23:45:00 AEST for 2026-09-02 00:00:00 AEST is 1.20","SA1 lower_reg 5PD@2026-09-01 23:55:00 AEST for 2026-09-02 00:40:00 AEST is 1.20 vs 5PD@2026-09-01 23:50:00 AEST for 2026-09-02 00:40:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 00:00:00 AEST for 2026-09-02 00:40:00 AEST is 0.37 vs 5PD@2026-09-01 23:55:00 AEST for 2026-09-02 00:40:00 AEST is 1.20","SA1 lower_reg 5PD@2026-09-02 00:05:00 AEST for 2026-09-02 00:25:00 AEST is 1.00 vs 5PD@2026-09-02 00:00:00 AEST for 2026-09-02 00:25:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 00:10:00 AEST for 2026-09-02 00:25:00 AEST is 0.37 vs 5PD@2026-09-02 00:05:00 AEST for 2026-09-02 00:25:00 AEST is 1.00","SA1 lower_reg 5PD@2026-09-02 01:15:00 AEST for 2026-09-02 01:55:00 AEST is 2.00 vs 5PD@2026-09-02 01:10:00 AEST for 2026-09-02 01:55:00 AEST is 1.37","SA1 lower_reg 5PD@2026-09-02 01:50:00 AEST for 2026-09-02 01:55:00 AEST is 1.37 vs 5PD@2026-09-02 01:45:00 AEST for 2026-09-02 01:55:00 AEST is 1.50","SA1 lower_reg 5PD@2026-09-02 02:30:00 AEST for 2026-09-02 02:35:00 AEST is 1.00 vs 5PD@2026-09-02 02:25:00 AEST for 2026-09-02 02:35:00 AEST is 1.20","SA1 lower_reg 5PD@2026-09-02 02:50:00 AEST for 2026-09-02 02:55:00 AEST is 0.72 vs 5PD@2026-09-02 02:45:00 AEST for 2026-09-02 02:55:00 AEST is 1.00","SA1 lower_reg 5PD@2026-09-02 03:20:00 AEST for 2026-09-02 03:30:00 AEST is 1.20 vs 5PD@2026-09-02 03:15:00 AEST for 2026-09-02 03:30:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 03:25:00 AEST for 2026-09-02 03:35:00 AEST is 1.20 vs 5PD@2026-09-02 03:20:00 AEST for 2026-09-02 03:35:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 03:30:00 AEST for 2026-09-02 03:35:00 AEST is 0.71 vs 5PD@2026-09-02 03:25:00 AEST for 2026-09-02 03:35:00 AEST is 1.20","SA1 lower_reg 5PD@2026-09-02 03:35:00 AEST for 2026-09-02 03:40:00 AEST is 0.37 vs 5PD@2026-09-02 03:30:00 AEST for 2026-09-02 03:40:00 AEST is 0.71","SA1 lower_reg 5PD@2026-09-02 03:40:00 AEST for 2026-09-02 03:45:00 AEST is 0.70 vs 5PD@2026-09-02 03:35:00 AEST for 2026-09-02 03:45:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 03:50:00 AEST for 2026-09-02 03:55:00 AEST is 2.00 vs 5PD@2026-09-02 03:45:00 AEST for 2026-09-02 03:55:00 AEST is 0.37","SA1 lower_reg 5PD@2026-09-02 03:55:00 AEST for 2026-09-02 04:00:00 AEST is 0.37 vs 5PD@2026-09-02 03:50:00 AEST for 2026-09-02 04:00:00 AEST is 0.71","SA1 raise_60sec 5PD@2026-09-01 05:40:00 AEST for 2026-09-01 06:00:00 AEST is 0.09 vs 5PD@2026-09-01 05:35:00 AEST for 2026-09-01 06:00:00 AEST is 0.03","SA1 raise_60sec 5PD@2026-09-01 06:50:00 AEST for 2026-09-01 06:55:00 AEST is 0.15 vs 5PD@2026-09-01 06:45:00 AEST for 2026-09-01 06:55:00 AEST is 0.09","SA1 raise_60sec 5PD@2026-09-01 07:25:00 AEST for 2026-09-01 08:10:00 AEST is 0.03 vs 5PD@2026-09-01 07:20:00 AEST for 2026-09-01 08:10:00 AEST is 0.09","SA1 raise_60sec 5PD@2026-09-01 07:55:00 AEST for 2026-09-01 08:10:00 AEST is 0.01 vs 5PD@2026-09-01 07:50:00 AEST for 2026-09-01 08:10:00 AEST is 0.07","SA1 raise_60sec 5PD@2026-09-01 15:30:00 AEST for 2026-09-01 15:50:00 AEST is 0.09 vs 5PD@2026-09-01 15:25:00 AEST for 2026-09-01 15:50:00 AEST is 0.00","SA1 raise_60sec 5PD@2026-09-01 17:50:00 AEST for 2026-09-01 18:20:00 AEST is 0.09 vs 5PD@2026-09-01 17:45:00 AEST for 2026-09-01 18:20:00 AEST is 0.04","SA1 raise_60sec 5PD@2026-09-01 18:20:00 AEST for 2026-09-01 18:45:00 AEST is 0.09 vs 5PD@2026-09-01 18:15:00 AEST for 2026-09-01 18:45:00 AEST is 0.03","SA1 raise_60sec 5PD@2026-09-01 18:25:00 AEST for 2026-09-01 18:55:00 AEST is 0.09 vs 5PD@2026-09-01 18:20:00 AEST for 2026-09-01 18:55:00 AEST is 0.03","SA1 raise_60sec 5PD@2026-09-01 19:35:00 AEST for 2026-09-01 19:40:00 AEST is 0.09 vs 5PD@2026-09-01 19:30:00 AEST for 2026-09-01 19:40:00 AEST is 0.03","SA1 raise_60sec 5PD@2026-09-02 01:00:00 AEST for 2026-09-02 01:05:00 AEST is 0.03 vs 5PD@2026-09-02 00:55:00 AEST for 2026-09-02 01:05:00 AEST is 0.09","SA1 raise_60sec 5PD@2026-09-02 01:25:00 AEST for 2026-09-02 01:35:00 AEST is 0.09 vs 5PD@2026-09-02 01:20:00 AEST for 2026-09-02 01:35:00 AEST is 0.04","SA1 raise_6sec 5PD@2026-09-01 09:25:00 AEST for 2026-09-01 09:45:00 AEST is 0.09 vs 5PD@2026-09-01 09:20:00 AEST for 2026-09-01 09:45:00 AEST is 0.00","SA1 raise_reg 5PD@2026-09-01 04:05:00 AEST for 2026-09-01 04:10:00 AEST is 4.98 vs 5PD@2026-09-01 04:00:00 AEST for 2026-09-01 04:10:00 AEST is 2.40","SA1 raise_reg 5PD@2026-09-01 04:10:00 AEST for 2026-09-01 04:40:00 AEST is 3.33 vs 5PD@2026-09-01 04:05:00 AEST for 2026-09-01 04:40:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 04:15:00 AEST for 2026-09-01 04:20:00 AEST is 4.98 vs 5PD@2026-09-01 04:10:00 AEST for 2026-09-01 04:20:00 AEST is 2.40","SA1 raise_reg 5PD@2026-09-01 04:20:00 AEST for 2026-09-01 04:25:00 AEST is 3.33 vs 5PD@2026-09-01 04:15:00 AEST for 2026-09-01 04:25:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 04:25:00 AEST for 2026-09-01 04:35:00 AEST is 3.68 vs 5PD@2026-09-01 04:20:00 AEST for 2026-09-01 04:35:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 04:30:00 AEST for 2026-09-01 04:35:00 AEST is 3.44 vs 5PD@2026-09-01 04:25:00 AEST for 2026-09-01 04:35:00 AEST is 3.68","SA1 raise_reg 5PD@2026-09-01 04:40:00 AEST for 2026-09-01 05:25:00 AEST is 4.98 vs 5PD@2026-09-01 04:35:00 AEST for 2026-09-01 05:25:00 AEST is 2.40","SA1 raise_reg 5PD@2026-09-01 04:45:00 AEST for 2026-09-01 05:25:00 AEST is 3.44 vs 5PD@2026-09-01 04:40:00 AEST for 2026-09-01 05:25:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 04:50:00 AEST for 2026-09-01 04:55:00 AEST is 4.98 vs 5PD@2026-09-01 04:45:00 AEST for 2026-09-01 04:55:00 AEST is 6.81","SA1 raise_reg 5PD@2026-09-01 04:55:00 AEST for 2026-09-01 05:00:00 AEST is 4.58 vs 5PD@2026-09-01 04:50:00 AEST for 2026-09-01 05:00:00 AEST is 6.81","SA1 raise_reg 5PD@2026-09-01 05:10:00 AEST for 2026-09-01 06:05:00 AEST is 0.42 vs 5PD@2026-09-01 05:05:00 AEST for 2026-09-01 06:05:00 AEST is 3.68","SA1 raise_reg 5PD@2026-09-01 05:20:00 AEST for 2026-09-01 06:15:00 AEST is 0.01 vs 5PD@2026-09-01 05:15:00 AEST for 2026-09-01 06:15:00 AEST is 3.38","SA1 raise_reg 5PD@2026-09-01 05:25:00 AEST for 2026-09-01 06:10:00 AEST is 4.98 vs 5PD@2026-09-01 05:20:00 AEST for 2026-09-01 06:10:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 05:30:00 AEST for 2026-09-01 06:10:00 AEST is 0.88 vs 5PD@2026-09-01 05:25:00 AEST for 2026-09-01 06:10:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 05:35:00 AEST for 2026-09-01 06:20:00 AEST is 7.80 vs 5PD@2026-09-01 05:30:00 AEST for 2026-09-01 06:20:00 AEST is 0.03","SA1 raise_reg 5PD@2026-09-01 05:45:00 AEST for 2026-09-01 06:00:00 AEST is 0.01 vs 5PD@2026-09-01 05:40:00 AEST for 2026-09-01 06:00:00 AEST is 5.00","SA1 raise_reg 5PD@2026-09-01 05:50:00 AEST for 2026-09-01 06:05:00 AEST is 2.40 vs 5PD@2026-09-01 05:45:00 AEST for 2026-09-01 06:05:00 AEST is 7.80","SA1 raise_reg 5PD@2026-09-01 05:55:00 AEST for 2026-09-01 06:20:00 AEST is 0.91 vs 5PD@2026-09-01 05:50:00 AEST for 2026-09-01 06:20:00 AEST is 3.10","SA1 raise_reg 5PD@2026-09-01 06:05:00 AEST for 2026-09-01 06:10:00 AEST is 7.80 vs 5PD@2026-09-01 06:00:00 AEST for 2026-09-01 06:10:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 06:10:00 AEST for 2026-09-01 06:20:00 AEST is 5.00 vs 5PD@2026-09-01 06:05:00 AEST for 2026-09-01 06:20:00 AEST is 3.38","SA1 raise_reg 5PD@2026-09-01 06:15:00 AEST for 2026-09-01 06:30:00 AEST is 1.00 vs 5PD@2026-09-01 06:10:00 AEST for 2026-09-01 06:30:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 06:20:00 AEST for 2026-09-01 06:35:00 AEST is 7.80 vs 5PD@2026-09-01 06:15:00 AEST for 2026-09-01 06:35:00 AEST is 1.00","SA1 raise_reg 5PD@2026-09-01 06:25:00 AEST for 2026-09-01 06:30:00 AEST is 8.00 vs 5PD@2026-09-01 06:20:00 AEST for 2026-09-01 06:30:00 AEST is 3.13","SA1 raise_reg 5PD@2026-09-01 14:25:00 AEST for 2026-09-01 14:30:00 AEST is 10.00 vs 5PD@2026-09-01 14:20:00 AEST for 2026-09-01 14:30:00 AEST is 4.67","SA1 raise_reg 5PD@2026-09-01 17:20:00 AEST for 2026-09-01 17:40:00 AEST is 4.98 vs 5PD@2026-09-01 17:15:00 AEST for 2026-09-01 17:40:00 AEST is 6.81","SA1 raise_reg 5PD@2026-09-01 17:25:00 AEST for 2026-09-01 17:30:00 AEST is 3.00 vs 5PD@2026-09-01 17:20:00 AEST for 2026-09-01 17:30:00 AEST is 3.45","SA1 raise_reg 5PD@2026-09-01 17:30:00 AEST for 2026-09-01 17:45:00 AEST is 4.58 vs 5PD@2026-09-01 17:25:00 AEST for 2026-09-01 17:45:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 17:40:00 AEST for 2026-09-01 18:10:00 AEST is 3.00 vs 5PD@2026-09-01 17:35:00 AEST for 2026-09-01 18:10:00 AEST is 1.46","SA1 raise_reg 5PD@2026-09-01 17:45:00 AEST for 2026-09-01 18:10:00 AEST is 3.45 vs 5PD@2026-09-01 17:40:00 AEST for 2026-09-01 18:10:00 AEST is 3.00","SA1 raise_reg 5PD@2026-09-01 17:55:00 AEST for 2026-09-01 18:25:00 AEST is 3.45 vs 5PD@2026-09-01 17:50:00 AEST for 2026-09-01 18:25:00 AEST is 5.00","SA1 raise_reg 5PD@2026-09-01 18:00:00 AEST for 2026-09-01 18:20:00 AEST is 7.80 vs 5PD@2026-09-01 17:55:00 AEST for 2026-09-01 18:20:00 AEST is 1.37","SA1 raise_reg 5PD@2026-09-01 18:05:00 AEST for 2026-09-01 18:20:00 AEST is 5.00 vs 5PD@2026-09-01 18:00:00 AEST for 2026-09-01 18:20:00 AEST is 7.80","SA1 raise_reg 5PD@2026-09-01 18:10:00 AEST for 2026-09-01 18:45:00 AEST is 5.50 vs 5PD@2026-09-01 18:05:00 AEST for 2026-09-01 18:45:00 AEST is 8.00","SA1 raise_reg 5PD@2026-09-01 18:15:00 AEST for 2026-09-01 18:45:00 AEST is 3.45 vs 5PD@2026-09-01 18:10:00 AEST for 2026-09-01 18:45:00 AEST is 5.50","SA1 raise_reg 5PD@2026-09-01 18:30:00 AEST for 2026-09-01 19:05:00 AEST is 3.38 vs 5PD@2026-09-01 18:25:00 AEST for 2026-09-01 19:05:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 18:35:00 AEST for 2026-09-01 19:10:00 AEST is 0.01 vs 5PD@2026-09-01 18:30:00 AEST for 2026-09-01 19:10:00 AEST is 1.44","SA1 raise_reg 5PD@2026-09-01 18:40:00 AEST for 2026-09-01 18:55:00 AEST is 5.00 vs 5PD@2026-09-01 18:35:00 AEST for 2026-09-01 18:55:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 18:45:00 AEST for 2026-09-01 18:55:00 AEST is 3.44 vs 5PD@2026-09-01 18:40:00 AEST for 2026-09-01 18:55:00 AEST is 5.00","SA1 raise_reg 5PD@2026-09-01 18:55:00 AEST for 2026-09-01 19:00:00 AEST is 0.01 vs 5PD@2026-09-01 18:50:00 AEST for 2026-09-01 19:00:00 AEST is 3.44","SA1 raise_reg 5PD@2026-09-01 19:05:00 AEST for 2026-09-01 19:20:00 AEST is 4.58 vs 5PD@2026-09-01 19:00:00 AEST for 2026-09-01 19:20:00 AEST is 6.81","SA1 raise_reg 5PD@2026-09-01 19:10:00 AEST for 2026-09-01 19:25:00 AEST is 3.44 vs 5PD@2026-09-01 19:05:00 AEST for 2026-09-01 19:25:00 AEST is 3.68","SA1 raise_reg 5PD@2026-09-01 19:15:00 AEST for 2026-09-01 19:25:00 AEST is 1.44 vs 5PD@2026-09-01 19:10:00 AEST for 2026-09-01 19:25:00 AEST is 3.44","SA1 raise_reg 5PD@2026-09-01 19:20:00 AEST for 2026-09-01 19:45:00 AEST is 3.00 vs 5PD@2026-09-01 19:15:00 AEST for 2026-09-01 19:45:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 19:25:00 AEST for 2026-09-01 19:50:00 AEST is 1.37 vs 5PD@2026-09-01 19:20:00 AEST for 2026-09-01 19:50:00 AEST is 3.00","SA1 raise_reg 5PD@2026-09-01 19:30:00 AEST for 2026-09-01 19:35:00 AEST is 3.44 vs 5PD@2026-09-01 19:25:00 AEST for 2026-09-01 19:35:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 19:40:00 AEST for 2026-09-01 20:05:00 AEST is 1.44 vs 5PD@2026-09-01 19:35:00 AEST for 2026-09-01 20:05:00 AEST is 6.95","SA1 raise_reg 5PD@2026-09-01 20:10:00 AEST for 2026-09-01 20:30:00 AEST is 6.00 vs 5PD@2026-09-01 20:05:00 AEST for 2026-09-01 20:30:00 AEST is 0.02","SA1 raise_reg 5PD@2026-09-01 20:15:00 AEST for 2026-09-01 20:25:00 AEST is 7.46 vs 5PD@2026-09-01 20:10:00 AEST for 2026-09-01 20:25:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 20:30:00 AEST for 2026-09-01 20:50:00 AEST is 4.98 vs 5PD@2026-09-01 20:25:00 AEST for 2026-09-01 20:50:00 AEST is 4.58","SA1 raise_reg 5PD@2026-09-01 20:40:00 AEST for 2026-09-01 21:20:00 AEST is 3.46 vs 5PD@2026-09-01 20:35:00 AEST for 2026-09-01 21:20:00 AEST is 3.83","SA1 raise_reg 5PD@2026-09-01 20:45:00 AEST for 2026-09-01 20:50:00 AEST is 3.38 vs 5PD@2026-09-01 20:40:00 AEST for 2026-09-01 20:50:00 AEST is 3.46","SA1 raise_reg 5PD@2026-09-01 20:55:00 AEST for 2026-09-01 21:05:00 AEST is 0.01 vs 5PD@2026-09-01 20:50:00 AEST for 2026-09-01 21:05:00 AEST is 2.26","SA1 raise_reg 5PD@2026-09-01 21:00:00 AEST for 2026-09-01 21:05:00 AEST is 7.47 vs 5PD@2026-09-01 20:55:00 AEST for 2026-09-01 21:05:00 AEST is 0.01","SA1 raise_reg 5PD@2026-09-01 21:05:00 AEST for 2026-09-01 21:45:00 AEST is 4.58 vs 5PD@2026-09-01 21:00:00 AEST for 2026-09-01 21:45:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 21:10:00 AEST for 2026-09-01 21:15:00 AEST is 2.26 vs 5PD@2026-09-01 21:05:00 AEST for 2026-09-01 21:15:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-01 21:15:00 AEST for 2026-09-01 21:50:00 AEST is 3.44 vs 5PD@2026-09-01 21:10:00 AEST for 2026-09-01 21:50:00 AEST is 4.98","SA1 raise_reg 5PD@2026-09-02 01:30:00 AEST for 2026-09-02 01:35:00 AEST is 4.10 vs 5PD@2026-09-02 01:25:00 AEST for 2026-09-02 01:35:00 AEST is 1.61","SA1 raise_reg 5PD@2026-09-02 01:40:00 AEST for 2026-09-02 01:45:00 AEST is 2.40 vs 5PD@2026-09-02 01:35:00 AEST for 2026-09-02 01:45:00 AEST is 3.46","SA1 raise_reg 5PD@2026-09-02 01:45:00 AEST for 2026-09-02 01:50:00 AEST is 7.80 vs 5PD@2026-09-02 01:40:00 AEST for 2026-09-02 01:50:00 AEST is 2.40","SA1 raise_reg 5PD@2026-09-02 02:55:00 AEST for 2026-09-02 03:00:00 AEST is 3.00 vs 5PD@2026-09-02 02:50:00 AEST for 2026-09-02 03:00:00 AEST is 4.98","SOE approaching higher operational limits set by asset operator for 2026-08-31 15:35 causing limited availability for product load energy","SYC Level Management - Rebalance Portfolio - SL","UPDATE CAPABILITY PARAMETERS FOR CHANGE TO OUTAGE PLAN/PLANT CONDITIONS","Weir Level Management - SL","Wind generation in TAS < forecast P5 SL"]},"REFERENCE_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A participants unique Reference Id","examples":["006799af-106e-4c0c-91e9-34d2f8dd54d1","01450942-74c9-4574-9093-4cf0995e842d","031e4b03-5b85-44d1-99b4-0438ff6f6039","033744bb-a43b-4a81-ac42-1bc7d0443977","034fba83-7bf7-4077-bb5a-0418f7d8f7b9","0364a17c-309e-48fb-8dad-f56ae03677ee","047e6126-bb87-4a46-93f0-9a44509d9c40","061bf821-dcc9-400c-9953-8cd8237f338b","062064da-5a52-460e-a983-626fb9f90fd1","09b57825-481e-4920-a9ba-d0b5f350a7b8-20260831030217","09c90d59-abdd-40c7-9014-c39ebb5e86bd","09f88aeb-dc0c-41bc-af5d-ad523b352784","0a3ca1cd-5447-4946-87e8-34bb923cfc24","0a579bcb-1e36-4f38-9c97-2a1c451ccf27","0b5daa2e-0d6d-4c7e-a53e-05810444c18a","0bda4c8f-479a-411a-9092-ce03328fd3f9","0c4f6e3e-7bf8-426d-94b9-f8631e352172","0ca022df-98a3-4faf-9549-b564630a07bb","0cdfb609-6914-48d8-9d61-53006168f0a3","0dac093d-bebc-451d-bf1b-e112db0e2b0d","0deeb962-3590-47b5-a1e5-11a58a22e039","0effc420-6f0d-4a43-85e8-ba8a8ab2d24b","1048bae2-dae1-44e8-b5b2-22653dab372b","10811bc1-e128-4e58-b54f-d51d107c2875","10a98107-56fd-4f70-805d-d90b376fa346","11036399-b0ba-45ac-ad6f-898d015a62f7","11380524-16fc-492a-ad61-0bce37dbf2ae","121fa063-792b-4b2e-9eb4-339bfd815a95","12350dc1-c54c-4e3f-b627-9acab86744f3","1354bdaa-8962-4aa4-8ac0-b5ecbfed0e31","13b33ada-8baf-4a3a-af36-afb06cd4514e","144b92df-4a70-4b0c-b061-568f71b09b41","14ca843b-a4cb-4070-a335-0c518459e268","15576752-2905-47cc-af61-fc67eee61ba0","15de90b9-c8a3-4447-a1a5-dd742e9612b4-20260901133952","16125b7e-b559-41a1-973a-1c66ffa060c3","1696fa1c-9e33-4689-a146-0c83e4e9091a","18baf7f4-4af2-4897-81d4-b5b682279fdf","18caafa9-bb1d-4291-a914-17ce6ce9b3c5","19a7eabe-2b71-4fc2-9a69-422af11533a9","1a24969a-9efb-41d9-b192-be32d930c3b8","1be4a42d-17ec-4849-b247-5cb60b3fc62a","1bf3e0fe-5040-4e09-afeb-98b064fd9ac7","1c3e8520-fd7f-4ef4-92c8-afed4fb2d2b4","1c4b1192-0c94-4342-a628-5e83334498ed","1cd9d1e3-01a5-4c24-9509-e4a5d3d13360","1d526984-faa7-4466-9eb7-6efe5d47be1b-20260901114021","1db9a546-f4e3-49e8-9c5c-bdc4239eb9bf","1e3e4c38-6551-4f79-b49d-f4690c4a3bb7-20260901160234","1fb4bc91-ea5c-4cb2-9b7d-006a928e5add","2036d701-7f06-4aa9-8dd7-0ffea1528980","212be3e8-df10-4a21-a961-75bfc8a5dd54","213609c0-ad01-4a74-9c32-78c32fb8ae09-20260901175645","22103480-7fb8-475f-ba3c-537a9a575085","225760f4-b719-40b6-8cb3-5ddcd1b20aa2","2338b037-46d4-44e2-8998-93462d030e96","2372777a-7437-4041-afa2-1ea3e40f857a","238f9c19-3019-4591-84ae-ebc3342510f2","23c0b717-9c17-4593-96c1-0f8891d1dec6","2545899d-7c6b-4fb6-a819-69b934a1ab5a-20260831204254","25e60f0d-ab44-44b6-b00d-7dd83c53fe5d","27ce08a0-a7bd-4e80-a1c3-6e93a6c0fce0-20260901100408","2889fff4-d6bb-4d6f-8364-58d872db6e4b","289e2d61-5424-4e9a-a552-7a77dc9fe5bd","29a3e0dd-816d-438f-b048-6bda7f9ec456","29cc7b93-5945-4ca7-9184-ab1b8413bf38","2aa32250-5e10-443f-869b-a6539fc7e9ed","2abac7b0-710c-4fcf-98e1-edc4bfef2174","2b600fa3-f2f0-4ac2-99d2-906c05974b61","2c2293f9-3ed2-4e44-bffa-05f01508d6d6","2d057cf0-d4b6-4cd7-bef0-9bf5d221fed8","2d6dbeb3-9b3e-43e8-bede-843b9e69128e-20260901160458","2da46558-b53e-4802-ad41-97999ff9d388","2dc2f9bb-d12e-4ebf-a6e6-7ef25aa61aff","2e14fd06-2c1c-4331-9c75-0b2782ccfc84","2e29ae19-b89c-42a2-9d74-50f49a4ea8e6-20260831120945","2eb76acb-797a-4bc9-8bcb-623fa441d132","2ee64478-1f03-4e98-bcab-ac6e143aad6c","2f1c87c6-3106-4fc3-976c-3ee37f767a31","2fc42ac8-58ec-445b-a867-9613e095af2a","2fe05f42-dddd-49a3-8a27-d66d65e801f3","30049247-a528-44cc-b0df-a1ad38123ae3-20260829030206","302a4877-f854-4fa3-bbe7-442671d0936a-20260831122249","30899c08-04fd-41b5-a23c-c303f4486a3b","316ed614-5730-4f43-9c1f-a09ad3276aef","317f2723-20bd-45ea-a8a3-3db87fb163f4","31cf4cdb-486d-43dc-bf0a-badf904ec37f","322e2c75-9ec5-4ddd-939b-1b7f95519ab1","3235922d-044c-4156-a630-106302b80319","327cbd8c-0b0d-459c-9bfc-085ae6d85ec6","336df071-016e-4c14-ae4f-ac6209266631","33daacfd-5cfd-4261-9c9c-a1a6da868d45","35dd5223-4fed-4a4c-b760-ad0fc18225d8","360cca1b-14d7-4317-ac5a-39f5ddc0503a","37019a78-3bee-4db5-b98a-fe8f241b910d-20260901181906","371f2700-c07b-4b7b-bf54-0d1c81df9066","3746eb93-42f4-44cd-b2fc-23a88552a0d8","379da1e5-4af5-45b9-8b4f-3cde5fbf9fa4","37b1ee73-fc55-495b-b1a3-31bbdfef1531","37b9c1a8-ae4c-4b31-a840-11e7e7ade5df","3add0609-3482-41dd-b399-48c919e25a8f","3ae0358a-27d2-42f1-a806-e4a7c5f3f994","3df401fe-abad-434f-8c21-f303e549f861","3e8531f5-6942-4c7d-b259-fb384305ddf3","3edcf0e1-9c90-4b46-af7f-49ed91ddf37e","3f8d0e1d-06f0-4d86-b439-c8479913e641","4061aa0e-853e-42b3-8c71-dc1fc9b2a951","40e2929d-102d-47ef-be2a-20617240e594","4134bb2e-48aa-4ce8-89c5-f97646ddcb1c","41da4cfb-1e68-4090-8f81-a5ae43c54d3d","425ec881-7e71-4557-b93c-591e04dcd718","42dc6821-d1fa-462d-a4d7-1db5fa1b137e","43795278-db02-42ab-a786-7ebf08cc3d1c","45db66de-9a1e-4ef2-a1fb-a1a97d840d9d","465a3d33-0ca7-4ff9-bba0-adfefca2d6fe","4687dda2-828e-40b8-b1cf-9631da652afb","481c7f31-30b9-4ffd-ad2d-3ad63cfe12a0","48513664-3f6b-4886-bffb-778888e87c99-20260831164339","49631571-8861-4abb-b0e3-2389c21535cb","49666794-4a4e-425d-8e3c-cb74b6177b45","4a017a84-58ec-463d-9e71-474b815494a3","4a14a9ca-8e3e-4a74-bebf-36d8c91a5f5f","4a7998fb-79b6-4221-847e-04b100737c7d","4a9e5f33-9df9-47ec-aa59-d077781383b7","4ad2b1fe-1ade-4730-9ef2-cecc65b8550d-20260831094130","4ae488e8-7b66-49d0-9d86-b99a7e2db9b8","4b942bcb-b545-47d7-9f95-882fc885dd38","4ce5c5da-262c-4fa5-9b96-527bddf408ba","4d028072-d31f-4108-bb39-e66d95ad2f56","4d066ca9-f1ab-46c0-a08e-46fef8a7db50","4d29c641-1534-4d87-9179-9deef933e7ff","4d3e0072-dcaf-4436-8b5a-0fbd39294117","4dfa92e1-2254-42a1-a9c7-5f8c2f12c42f-20260831145140","4e4a00a3-3086-4997-9605-f15754678127","4eb0de9b-b554-4cc6-bc8a-cfaa673b3a4b","4f5ce445-56ff-4eaa-8ec9-93f5ca84d16b","4f5e67ce-f379-48f9-bc3e-ebf54b6329bf","4f96e6cb-c10f-4979-b3ee-4e5fd8325c6f","4fc1dae3-3084-46d8-856a-16eed8ff726a","50338606-4791-4cf5-9a02-7a97fa37d652","50f83a71-998d-4046-8094-4f607a9588bc","52b2e7d0-5e3b-4c3d-8467-ff356ea8328d","52d02617-1595-40ef-976a-5a4dcbb002f5","53e19034-047a-4143-a4b1-9c1c3e28d657","54ea3d33-3e30-40d6-9c32-094f0f9a9956","5581374e-4674-4815-8d85-3b735a5b9b56","55959b0f-319c-4458-8e83-89607bec84a6","5655dbbb-3742-4c50-b664-94495acdb57a-20260901202637","583d5018-2325-4251-aecb-531783eebb9c","58e944d2-9e55-4933-ab8c-0849712ace42","58ea462c-c0d8-4133-96cd-106917f689c6","59633cbd-c24c-4abc-bdad-5399ff1028bc","5a175923-bf93-4750-a798-83bef41428be","5a6bdab4-b742-4349-9fc9-d41e406b70ab","5aaf7514-f357-4ecd-b8ab-8d0c3f685dc1-20260901191914","5ace6b24-76b4-4b41-8025-6d21c70e8fd4","5c7425bb-ebda-4439-876f-a29fb01ecb24","5db838e1-30ef-4dbf-819d-3c3fd417ef72","5dce75b3-61d2-4aee-9bb4-2571b4ef59dd","5ec6c728-533a-4a99-a3e6-1e434332f898","5f89885a-1c7b-4722-b38d-b4a10116716b","5f8c3df2-a148-493f-91b3-d34ac1707ca2","5f9b7a26-2ea3-4c77-ab53-5af8801c68ec","5fc286ed-6791-4f79-a020-f6f87a6c1a2f","6103cf2c-84fc-48a6-9eb5-5992a357d016","617adb08-a892-4e58-80f8-bca3bfb0e215","61833522-8149-43f7-b1d1-785b3380973e","61dc3983-b455-4ef0-bc0c-040edced1952","63fce183-e6c7-4bbe-9299-d64b9386dae8","64026622-84ed-4888-9172-b3dbd40feda5","656ff6e8-635c-4e86-80ee-11c408ff587c","6632a5f8-8d79-4349-9965-7ecea0e99a23","6640510c-77e1-40bb-9596-4da0525b9375","6710cb76-ca1b-4205-929e-dc2efc8c3bcc","682253b3-c754-4d2c-bbcb-baaf2b405f32","694e887a-8e18-4ec3-a937-351a01d822bc","69881d24-2f7f-4e5b-ac2f-0eaedd1b07a9","69a25016-96f4-4543-af86-3ffb92c04275","6a4cbaac-e703-48d4-a3de-1cdfe53a6ab7","6a980164-e5a1-418e-96d6-ea748c0caad1","6b6405ad-98d0-467a-b977-e4427671e10e","6bca04cd-1e32-4111-bd5e-2e6399b5ab47","6dfb2d40-df5a-4055-98e8-8ff9fe08c478","6e176885-d129-4da5-bfae-94c44a6d734c","70ec6c29-6a96-4261-b0de-0e8ee16a43d3","70fd97fe-bea7-4a25-ae1f-668ba9b87123","71e7e16d-fd11-40cf-8110-018112f26da4","726048d5-c481-4c35-a7b5-52b7332d00c3","72df87c1-14f7-42da-ab2b-f5f082bd2632","72e5087f-47f4-4e26-806f-2537d6fbbec4","7330a9d7-df28-4d07-b6ad-9fac7617f025","7427a128-0d48-4716-bab5-5ef405ec0244","742b9fb4-2711-4155-8fad-dcb4ee78b5be","75f26076-9c88-43c6-9e91-e70ecf769e43","760b796b-f778-4769-81cc-748e0c4dc640","765f6c79-4044-4142-ae37-a9e4f6d4f892-20260831141429","769cfbcb-2cab-43da-9bc1-5f494de28537","7718f6a3-7a2f-4165-9a82-6f5e1006d96d","784ac0b5-edf4-4901-a332-57350fdf708d","78e28c58-4960-4a90-b681-62631de53325","791e1504-1ef1-4893-96ca-8b87d300f96d","7a09ca9a-fc94-46dc-8b91-2bbdc7604fc0","7b168d8d-54b4-497f-988e-44b7f2540e97","7b17f410-77b1-4372-a780-48ec21e8c49b","7b455c23-bd26-4b10-9c97-6e845b5dc975","7b642c38-cf36-4e80-9839-39139180230e","7c10349c-7409-4c0a-9132-d7cdb3a423a1","7d2c48a3-6756-4307-9e74-eaded7e8dcd1","7d4283a7-9f6f-4597-b583-7d1c18da986e","7f1d27a4-cc2a-4442-a6d6-5b830c7a3bf6","7fdb6235-a8a3-4323-be11-e1cabfcb566b","7fe7f535-0cb7-4f7d-bf0b-ec71b3aeab55","7fee883f-9bd9-4e2c-acd9-9e17781b658a-20260831111028","805aeb6d-add0-4d91-9f97-cfb19c486050","80f631c3-d22a-4bc1-87ba-66015263da53","81b480a2-b1e1-404c-8ee0-aeb6f0927e1f","830fa81c-99d5-427c-b54b-25c74c65a342","8331dedb-1298-4fc0-a735-414d64289123","837a966c-90a4-4b73-bc35-8c837d612793-20260828030216","8459982f-68ee-4d75-bacd-53eed0d070c2","84ac3fd1-e53e-4d1f-b853-aa9d4a87242e","84ae96e5-b4bc-40ab-b8a7-500d5b61b2c4","84d13809-69ce-45e6-a929-dcf99fc09dc9","8633686f-f065-4b59-a6d5-e855766719e0","868b236a-cc16-4621-9b32-094e26643914","874af32e-fd9a-425e-92fe-5aec46d9c6a6-20260901120841","87ca40a0-55d5-4792-a414-f1f72efc9c99","881493bb-4b71-4369-bdda-f71f1c96be98","8871a71a-509a-4a7a-b93f-1514d90eba03","8a22edb3-02cb-4a97-8a21-caa910bf53aa","8a812f86-9e2a-4d48-aa5c-036270ee80ac","8b855492-f0c3-48b0-8e4f-10fd651f67fc","8d15a636-60fa-4c8d-a102-0bf250ccfd2f","8df32c99-76a4-4e8c-abb4-e3ee6989c840","8e0c1948-0cf1-4c20-b359-5e95766cdb05","8e486f86-f997-42c5-a0ec-4d21821890fa","8eef92f2-03cb-4902-9515-bde14a0f8a68","8f14f699-8a19-4d1b-a9bc-4d5193d476aa","8f60a37a-7bdb-4094-adbd-8378eefcb92f","8fdb723d-cf4d-43de-80ea-69c75b9db375","90f8ead2-5a02-4d98-aafe-2dcda416c600-20260901152441","9115f7f5-f4ca-4201-8e04-3982a7959f6e","922c9793-8978-4608-a967-111bbcbb49a5","94c1bf13-5931-43ce-9cf6-f01bbb6ce899","962667f5-8212-4aff-b7e7-0d8af3dc5d5e","964f3ced-f0a8-4744-9504-9a0049aadd96","977070e1-1003-4263-b571-dda8d56f33f9","97899273-a436-490d-a9d0-639f91fa194b","97ba7af5-a6ad-4cd6-9d1c-0a51d53545a6","98262882-fd30-494c-86c3-6d0ccc18e9f7","99a75cfa-9ff9-4860-b672-30ff7bb6a884","9a0dff00-daf0-41aa-970a-2578a357158c","9a56297d-3bd9-45b0-a520-39baf49610e3","9b26c1f9-0b66-4573-b787-d6463628f100-20260826030211","9ba8fcb7-ae53-41fd-980f-29e82b83be8f","9c7ca897-78cf-488c-95b6-c69ba849e518-20260901074714","9dd10b64-a0b5-4bed-86e1-6c9e7a877526","9e87543e-79c2-4aa6-b314-8a756fd2eda2","9ed622f6-6b98-4ebf-91f7-0d67d8cbb93e","9edf9c37-f3d2-4615-8296-456a2464b279-20260831133533","9fa41cac-bebd-4491-987f-ad41354a8cc6","ALNTARES_EO_20260901_20260717140741560","ALNTARES_EO_20260901_20260812143746078","ALNTBHWF_EO_20260901_20260717140610856","ALNTBHWF_EO_20260901_20260812143718276","BALBESS_EO_20260901_20260823131534240","BALBESS_EO_20260901_20260823145058788","BALBESS_EO_20260901_20260831123411708","BALBESS_EO_20260901_20260831130912565","BALBESS_EO_20260901_20260831133411977","BALBESS_EO_20260901_20260831140910342","BALBESS_EO_20260901_20260831143410219","BALBESS_EO_20260901_20260831145910891","BALBESS_EO_20260901_20260831150411907","BALBESS_EO_20260901_20260831152410285","BALBESS_EO_20260901_20260831153411911","BALBESS_EO_20260901_20260831160413756","BALBESS_EO_20260901_20260831163411772","BALBESS_EO_20260901_20260831170410313","BALBESS_EO_20260901_20260831173436223","BALBESS_EO_20260901_20260831174913024","BALBESS_EO_20260901_20260831180414595","BALBESS_EO_20260901_20260831183413979","BALBESS_EO_20260901_20260831190916750","BALBESS_EO_20260901_20260831193414397","BALBESS_EO_20260901_20260831200418105","BALBESS_EO_20260901_20260831203413080","BALBESS_EO_20260901_20260831210414910","BALBESS_EO_20260901_20260831213415159","BALBESS_EO_20260901_20260831220416615","BALBESS_EO_20260901_20260831223416845","BALBESS_EO_20260901_20260831230421344","BALBESS_EO_20260901_20260831233414538","BALBESS_EO_20260901_20260901000417580","BALBESS_EO_20260901_20260901003419793","BALBESS_EO_20260901_20260901010419050","BALBESS_EO_20260901_20260901013416069","BALBESS_EO_20260901_20260901020910903","BALBESS_EO_20260901_20260901023419964","BALBESS_EO_20260901_20260901030420391","BALBESS_EO_20260901_20260901033421692","BALBESS_EO_20260901_20260901040408663","BALBESS_EO_20260901_20260901043406743","BALBESS_EO_20260901_20260901050408226","BALBESS_EO_20260901_20260901053407236","BALBESS_EO_20260901_20260901060411537","BALBESS_EO_20260901_20260901063406580","BALBESS_EO_20260901_20260901070408975","BALBESS_EO_20260901_20260901072905713","BALBESS_EO_20260901_20260901073406798","BALBESS_EO_20260901_20260901074407842","BALBESS_EO_20260901_20260901074908555","BALBESS_EO_20260901_20260901075405843","BALBESS_EO_20260901_20260901075906545","BALBESS_EO_20260901_20260901080414396","BALBESS_EO_20260901_20260901080905778","BALBESS_EO_20260901_20260901081406469","BALBESS_EO_20260901_20260901081905894","BALBESS_EO_20260901_20260901082405755","BALBESS_EO_20260901_20260901082908475","BALBESS_EO_20260901_20260901083406836","BALBESS_EO_20260901_20260901083907275","BALBESS_EO_20260901_20260901084405980","BALBESS_EO_20260901_20260901084906532","BALBESS_EO_20260901_20260901090416431","BALBESS_EO_20260901_20260901090522013","BALBESS_EO_20260901_20260901090908472","BALBESS_EO_20260901_20260901093409217","BALBESS_EO_20260901_20260901100406231","BALBESS_EO_20260901_20260901105408226","BALBESS_EO_20260901_20260901115409645","BALBESS_EO_20260901_20260901123411094","BALBESS_EO_20260901_20260901130922547","BALBESS_EO_20260901_20260901133417223","BALBESS_EO_20260901_20260901140911933","BALBESS_EO_20260901_20260901143415033","BALBESS_EO_20260901_20260901150424278","BALBESS_EO_20260901_20260901152258656","BALBESS_EO_20260901_20260901152412697","BALBESS_EO_20260901_20260901152912427","BALBESS_EO_20260901_20260901153411860","BALBESS_EO_20260901_20260901160417453","BALBESS_EO_20260901_20260901163414620","BALBESS_EO_20260901_20260901170419548","BALBESS_EO_20260901_20260901173415747","BALBESS_EO_20260901_20260901180417862","BALBESS_EO_20260901_20260901182411638","BALBESS_EO_20260901_20260901183425466","BALBESS_EO_20260901_20260901190414971","BALBESS_EO_20260901_20260901190909662","BALBESS_EO_20260901_20260901191408213","BALBESS_EO_20260901_20260901191912720","BALBESS_EO_20260901_20260901192407948","BALBESS_EO_20260901_20260901192907271","BALBESS_EO_20260901_20260901193419067","BALBESS_EO_20260901_20260901193907709","BALBESS_EO_20260901_20260901194412661","BALBESS_EO_20260901_20260901194911273","BALBESS_EO_20260901_20260901195409570","BALBESS_EO_20260901_20260901195910625","BALBESS_EO_20260901_20260901200436921","BALBESS_EO_20260901_20260901200907578","BALBESS_EO_20260901_20260901201411182","BALBESS_EO_20260901_20260901203424778","BALBESS_EO_20260901_20260901210419441","BALBESS_EO_20260901_20260901213418444","BALBESS_EO_20260901_20260901220412116","BALBESS_EO_20260901_20260901223421939","BALBESS_EO_20260901_20260901230424443","BALBESS_EO_20260901_20260901233421904","BALBESS_EO_20260901_20260902000416166","BALBESS_EO_20260901_20260902003413293","BALBESS_EO_20260901_20260902010413287","BALBESS_EO_20260901_20260902013419913","BALBESS_EO_20260901_20260902020420591","BALBESS_EO_20260901_20260902023417884","BALBESS_EO_20260901_20260902030415875","BALBESS_EO_20260901_20260902033909923","BANGOWF2_EO_20260901_20260823204000983","BBPEM_EO_20260901_20260831121514713","BWFTRUST_EO_20260901_20260823204000983","HALLETT_EO_20260901_20260823101841865","HALLETT_EO_20260901_20260831121535724","HALLETT_EO_20260901_20260901073437744","HALLETT_EO_20260901_20260901095418298","HALLETT_EO_20260901_20260901122303868","HALLETT_EO_20260901_20260901175833006","PTP E -------- ---- 20260824 OV 000 : c5054416-28e8-44f4-b8cf-5c4ee3ad4575","PTP E -------- BARRON-1 20260820 OV 000 : 081b9dfa-48d9-4794-8805-75ca72b09137","PTP E -------- BARRON-1 20260828 OV 000 : 4cfe9e81-6b92-445a-af6e-053b51602263","PTP E -------- BARRON-2 20260820 OV 000 : b017e140-33e9-4203-9ac1-6aac098be770","PTP E -------- BARRON-2 20260831 OV 000 : 5852564c-26c5-4eb2-bd54-10d26f11195b","PTP E 20260901 ---- 20260831 OV 000 : 6e2ade4a-fe25-4911-91a6-a665b741b217","PTP E 20260901 BARRON-2 20260901 OV 000 : 03f50141-6bea-435c-9d39-f0e85a849c91","PTP E 20260901 BARRON-2 20260901 OV 000 : 4ffb0da4-e5c1-4755-9eaf-4dccd4a4f10d","PTP E 20260901 BARRON-2 20260901 OV 000 : ac90a2cf-844b-4627-87c7-2d2e715cc82a","PTP E 20260901 BARRON-2 20260901 OV 000 : fd880f72-d8bd-4bb0-94b2-06e6dda33e55","PTP E/F -------- ---- 20260901 OV 000 : c8221a61-a628-4e11-8aa6-2f265ff3089a","SOUTHHYD_EO_20260901_20260819132710533","SOUTHHYD_EO_20260901_20260830093955661","SOUTHHYD_EO_20260901_20260831101918556","SOUTHHYD_EO_20260901_20260901113547026","TIPSCO_EO_20260901_20260817092533403","TIPSCO_EO_20260901_20260831161628887","TIPSCO_EO_20260901_20260901081745731","TIPSCO_EO_20260901_20260901172623686","TIPSCO_EO_20260901_20260901191635837","TIPSCO_EO_20260901_20260901201205621","TIPSCO_EO_20260901_20260901214724165","a03c71f2-70b0-4146-b771-c6e84c6af4b8","a05682a4-4703-4f38-a77d-9f1bfdffce86","a09116d6-c650-42ca-aab7-6e50bb1cbbf9","a183f5d2-e692-4091-a203-dace1dda13ea","a1ce4407-40a5-4697-b123-1edef31a2269","a207846e-20a6-4b21-8b22-466bbd2c3ef5","a38dc223-cf89-4d18-8454-c00b19d7fc29","a4d95879-e542-4987-bda0-55a44d8ee020","a4edbc84-669c-4ed6-b3c8-8d0dcc840c03","a66055e2-72ca-4d77-a8c0-08b23af52926","a6652437-3bb8-431a-9ad9-80a48f8212b6","a66b456d-2ee5-4a89-b9f7-71e61b636fdd","a7ee796e-d34c-4c59-a6dc-c4ac2c04ded5","a86ded38-fe0c-49fc-9665-a726dc2aa1ea","a8aeeeb7-7477-4bdc-a3ed-a69833c356a0","a935a261-f997-4adc-9424-b91d5987fffd","a987df50-52e8-46f2-92a5-0ec40aa05eb6","a988433a-ea58-4d85-b7a7-45ff9b98ac6b","aa28bdba-4945-4800-9340-bc6b9521be54","ab87439d-7bdf-4da3-9a1d-a7b801faa82a","ab9b8b21-a45c-4c42-8075-61988152932d-20260831153847","ac1e6974-7050-49ca-aa9c-61c01544da08","ac3e896c-d65f-4dd8-acd8-ece1ad0802f2","ac7d4cbf-862e-4b50-a495-c923960364f7","ad737538-2413-4d7b-8224-4ae7990043b0","ae4756b2-558c-4e0c-811c-fdcdbcb2bf2a","ae73c651-d4d7-4176-9b71-c698e4c5da4a","af13ce7a-c138-47e1-803f-3fb721e8cc04","b08689b7-cefa-46f4-9a14-f4e3cbc189ce-20260831090016","b0880894-5860-409b-b2c5-a93c801c52b6","b0ca4944-08f7-4e76-823d-619e0b6862f5","b25c35d3-ae4a-4fbc-a9e0-642a2ef67222","b3192727-ada0-4c26-a4ca-0a3213a7e495","b4b8618b-4a13-4f2f-85ae-55e357d0d994","b59d7f70-cce9-405c-af98-5e7ec3ea8dfa","b5b5b5f2-b48c-4c4a-a9a6-4a95a0260f73","b641f9c0-88c4-4ca5-8048-7b3bfef9fe24-20260825030159","b6d6e52a-f11d-4acf-b157-e5334485df2a","b73e46e8-bc04-4ac1-9ec7-b564f9990a69","b7491a47-26d2-474f-8d64-91c3933c5789","b7d444e7-4715-4e12-a32f-5250aab28f29","b91f2d31-a8e2-4f52-b47d-ff8797ac2089","b932aee1-9ad5-468f-9836-c5cea099af08","b96b7d2b-54d9-460e-a330-852c93e0401d","b9ce62df-ea19-4297-889a-ec105794e8c3","bb443ab8-6fa1-42aa-b8d0-133ceb38daff","bb64dee5-db91-41ae-8dec-e9ebabfd1e48","bc20ac68-bece-4434-ab9a-2540f475cd53","bc2ed90e-9edc-4e30-9246-4c73749528ec","bce773e8-6796-43de-86db-75215988ee97","bdbe4388-bcc0-4958-9deb-3fc3f05e7190","be7004e1-4cb5-425e-a1a7-3a150c8bfcf5","bf322253-daaa-4526-9b10-76daef84ea77","bf3faaef-e5bd-4004-8150-efcb6e8e6a20","c019a50e-4650-4e33-a65f-f80004bb3d4d","c0dd3304-7e24-46be-955d-e1a06681d9ee","c2e76464-9e13-4e9a-9cd7-bc238ad929c8","c41234d5-bdb2-45e4-94c4-d21c709a1bba","c44eb66d-f000-4e9e-aec4-51a3e07306a5","c480bfcc-c892-4f05-bcc9-c89710a7e20f-20260901174143","c5419bbe-5b37-417c-ad8c-eee98c511dd6","c583a327-4a74-4007-b7e1-cc1ab683b264","c6bd033f-b106-4417-824a-893045b8a67a-20260901162027","c7c3326d-009f-411b-80ae-6156a92262df","cb8d6db6-8f0e-49c2-ae44-7b24a1e95712","cbcdce86-7238-4fa9-9b4f-3f9b290fbd67","cd189868-0b5d-40a3-a27a-dd32b48b7724","cd9e2aa0-09e7-484e-931d-e45dbeeae611","cf4e1694-b2bc-4baa-8b71-2ca75fcadc25","cfda81dd-9159-4d5a-af22-f12b1da29d31","d04d49db-09b2-4006-a0f9-52d27d1d1f7a","d1de317c-6273-4b4f-9ffd-fe298ef46fc1","d248e175-a461-4630-8bbd-ce6b42a0013f","d5198fee-5cf2-4b97-b494-f004715911cf","d6750aa8-8f31-4fdd-831a-4495267d4c24-20260831113653","d701dcd6-1c63-45e4-87a8-3bb47ff7cadb","d7070c39-400f-4e5c-a541-56e83ac400c5","d7899aa6-e645-4729-a452-5f469bec2d33","d79436ef-e0fe-4882-b487-bcda9bbce712","d799af5e-ed77-401d-9af3-f39f83e831b5","d8843a5f-e2d0-477b-9be6-9e90843d42f5","d891fa1d-779a-47bd-8a95-e0d0da2ea38f","d9b98dc1-95b7-4923-81a0-5e4321f1b113","db85acad-6e89-46b8-8bb1-56fb9ee77855","db895013-8f61-40c6-849d-499780d24095","dbbdf61f-bd97-43ef-9115-61a3629ae6d4","ddc9565f-4824-4cc6-b70d-de4d12448e52","de6160ab-7c5b-401b-8390-a3dabbd94da2","de88c169-5a6f-4ceb-9519-4300fd69118b","df5a1081-b41d-4e3b-9f05-48460343da0b","df5f1093-fdd5-4182-991e-5651d7511b9a","e078923a-bc9e-446a-bf6d-f237e52525b9","e0c4fb8c-bcec-4b1b-ad80-e0f01e3d312c","e1430a06-3e7a-4342-bc9d-bafd57562792","e1e4d334-450c-4f08-a9c5-0367816e179f","e236704e-7ad2-4180-af9a-735edc531707","e33a602a-c552-48f2-8ded-e6d9df613e7d-20260827030149","e33a6a91-455d-41ab-90c7-0bb7a1eabef3","e3d3f5f7-2270-44cd-91fa-a96991eb43c1","e42b5696-20cd-4f5c-ac5e-e68b1d547e87","e42d7454-4bb5-4b82-bf0d-23bf3fc4fdeb","e45b519b-4152-4649-b4bb-085d15f19938","e5210be6-ac81-4497-a90e-f7e1e562e7a2","e54aefa2-c62f-4344-8eef-19f667912502","e5f81bbc-e3c6-4dac-992e-529a3e74017d-20260901004313","e72975c0-d7ad-4eb5-bbbf-2b553c0b5114","e7eee6b2-2d18-41b4-8785-d62ad761220a","e8403696-45f2-4d34-bd6a-6a78041015b7","e85e715d-e853-4145-8e23-3758641934f0","e95106c6-2ee8-4ed7-9c36-6ceb4495011a-20260901180907","e9ed4304-c1eb-42c5-a0bf-c09b62917c68","ea8b91ba-7182-4980-b506-3c773d8e7d15","ebbe3e54-6a39-4b5b-ab5d-d1d28576363e","ebe36c2f-a4a2-4146-95b5-b0cb29dae390","ecd68b4b-373a-4d55-966d-65d37c14e5c5","ece5e4f7-4c22-4ef2-94db-86e3e93147b4-20260831083911","edea7477-e80b-48a2-b3d5-1bae6a67592d","f0293c73-698c-4c85-a246-9f3d51c520fc","f12dd108-eae4-4baa-bf93-96b9ae609309","f1eeb138-b8dc-4839-a338-a55486b8c08b","f245c9b8-7e89-444d-a170-1875f5b64cc2","f26e0f70-6130-4e84-9c5a-1bac6a73bbaa","f29de3e2-e639-4afc-90e5-39380f8998e9-20260830030157","f3800b45-1c69-45f5-bc25-b0e942ae157b","f39fc1c9-11e7-45b6-8c70-e8adf82ae0f4","f4d9eee6-b87b-498c-aca1-75a6f44299d2","f54f5995-a179-4b1f-b2ff-1e0cd4b42246","f5717fea-a77b-4265-9832-c430b11df20d","f5df0539-295a-47ef-b3ed-7ebf25254051","f5ebbe41-7940-406b-bd22-7bdd392c6511","f7103c21-a7e8-42a9-9b02-081d9aae5204","f76da0c9-0888-4634-b477-719bb6b39a4e","f83db984-f880-4ab4-8d81-06e8bd5995b0","f8ac2432-e6a7-4b3c-afb9-b8de19a2d963","f8b31b5e-54c6-4682-90d2-e1c3139556ca","f977d424-d5c0-4291-944a-b8488b77c658","f9b125e9-71e4-47bd-9102-080d65fa21f3","f9b25951-e937-4c26-9bff-ff2981544014","fac642c2-81db-4e97-893c-51c6446c5d07","fb931a63-3b7e-40cd-bb06-b593e92cd3ec","fd129fdd-3d5f-46c2-8a9b-f31c2d5f9cd1","fda3e3a2-4c50-4de0-bf3f-bd7b2b8886b0","fdddf03d-df73-4fdb-aac7-eab27e58e335-20260826140725","ff5181ea-3585-46e1-b500-7070a9230c3f","ffa839a5-6211-4a33-8887-54c1153f8635"]},"T1":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to synchronise in minutes (Energy Bids Only)","examples":["0","7","20"],"is_integer":true,"num_int_bits":128},"T2":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to minimum load in minutes (Energy Bids Only)","examples":["0","2","7"],"is_integer":true,"num_int_bits":128},"T3":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time at minimum load in minutes (Energy Bids Only)","examples":["0","1","35"],"is_integer":true,"num_int_bits":128},"T4":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to shutdown in minutes (Energy Bids Only)","examples":["0","2","7"],"is_integer":true,"num_int_bits":128},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":false,"comment":"Version No. for given offer date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"NORMALSTATUS":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Boolean","mandatory":false,"comment":"not used; was ON/OFF for loads (Energy Bids Only)","examples":["ON","OFF"],"unused":true,"parse_csv_as_string":true,"value_map":{"ON":1,"OFF":0},"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDDAYOFFER%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":284910630,"decompressed_size_all_time":94974519090},"visibility":"Private & Public Next-Day","trigger":"Data is published whenever new bid data arrives"},"BIDDAYOFFER_D":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"BIDDAYOFFER_D","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#12"],"comment":"BIDDAYOFFER_D shows the public summary of the energy and FCAS offers applicable in the Dispatch for the\nintervals identified. BIDDAYOFFER_D is the parent table to BIDPEROFFER_D.","description":"BIDDAYOFFER_D data is made public after 4am the next day.\n\nSource\n\nBIDDAYOFFER_D updates as ancillary service bids are processed.\nBIDDAYOFFER_D shows latest accepted energy and ancillary service bids.\n\nVolume\n\nSummary - approximately 1,000 rows per day","primary_keys":["BIDTYPE","DIRECTION","DUID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DIRECTION":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"GEN\", \"LOAD\", \"BIDIRECTIONAL\"])","mandatory":false,"comment":"The power flow direction to which this offer applies: GEN, LOAD or BIDIRECTIONAL","examples":null,"warnings":["Despite AEMO's documentation saying that this column is mandatory, it is missing from older files. It was added to the schema in [version 5.3](https://tech-specs.docs.public.aemo.com.au/Content/TSP_EMMSDM53_April2024/Participant_Impact.htm#NEXTDAYbids).-"],"enums":["GEN","LOAD","BIDIRECTIONAL"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNAES1","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSERDV1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DPNTB1","DRACAV1","DRAESN3","DRAESS1","DRHTVP03","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT04","DRVIOT06","DRVIOT07","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","RESS1","RIVNB2","ROMA_7","ROMA_8","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VENUS1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VSNEL2S1","VSQHT1V1","VSSAE1V1","VSSSE1V1","VSSSH1S1","VSVEL2S1","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date for which the bid applied","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BIDSETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Market date for which the bid was submitted.","examples":["2020/08/21 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DAILYENERGYCONSTRAINT":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum energy available from Energy Constrained Plant. (Energy Bids Only)","examples":["0","148","31299"],"is_float":true},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"DAILY\", \"REBID\", \"DEFAULT\"])","mandatory":false,"comment":"Daily if processed before BidCutOff of previous day, otherwise REBID","examples":null,"warnings":["AEMO says this field may take a value of `Daily`, but it actually is `DAILY`.","Despite AEMO's description, this field may occasionally take on a third value, `DEFAULT` for [RERT](https://www.aemo.com.au/energy-systems/electricity/emergency-management/reliability-and-emergency-reserve-trader-rert) (e.g. with virtual `DUID`=`RT_NSW1`, participant `NEMRESTR` and explanation \"Initial Reserve Trader Default Bid\").\n"],"enums":["DAILY","REBID","DEFAULT"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2020/08/19 11:54:38"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUMLOAD":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Minimum MW load fast start plant","examples":["0","1","230"],"is_integer":true,"num_int_bits":128},"MR_FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Mandatory Restriction Scaling Factor","is_float":true},"NORMALSTATUS":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Boolean","mandatory":false,"comment":"ON/OFF for loads (Energy Bids Only)","examples":["ON","OFF"],"parse_csv_as_string":true,"value_map":{"ON":1,"OFF":0},"is_boolean":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Offer date and time","examples":["2020/08/19 11:54:38"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","examples":["ACACIRET","ACLESGA","AGLE","AGLES","AGLLBESS","AGLWBESS","ALDOGASF","ALNTARES","ALNTBHWF","AMALMASP","ARARATWF","B2PS","BALBESS","BANGOWF2","BBPEM","BERBANK","BERBANKW","BERYBKWF","BLYTHBAT","BOCOROCK","BODWF1","BOMENSF","BORAL","BOULBESS","BRNDBESS","BULGANA","BUNGALA1","BUNGALA2","BUNGBESS","BUSF","BWFTRUST","CAPBESS","CAPRISF","CAPTPL","CARWARP","CATHROCK","CGBESS","CHERRYWF","CLARESF1","CLEANCO","CLEMGPWF","CLERMSF","CNUNDAWF","COLEAMSF","COLLECWF","COLUMSF","COOPGWF","COROWASF","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CUSF","DALBYSGA","DALRYMPN","DARLSF","DAYDSF","DDSF","DELTA","DIAMDGEN","DIAMOND","DISCOVER","DPNTBESS","DULACCA","DUNDWF","ECOGEN","EDENVALE","EDISON","EEQ","EEQGEN","EEQLILY","EEQMEWF","ENELAUS","ENGYAVIC","ENOCMASP","EQMREHA1","EQMREHA2","ERMPOWER","EVERGEN","FINLEYSF","FSNSW","GANNBESS","GANNSF","GBATEAST","GESF","GLENROSF","GLENSF","GOON","GPWF1","GPWF2","GRANHAWF","GROUPNRG","GSPOWER","GSWF1A","GSWF1B","GUNNEDAH","GUNNING","GUNSYND","HALLETT","HAMISF","HAUGHTSF","HAWKES","HAYMSF","HBESS","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HTWIND","HWF3","HYDROTAS","JUNEESF","KARSF","KENNEDYE","KERANGSP","KIATAPRJ","KIDSPHES","KINGARSF","KOORBESS","KSFPROJT","LALLALWF","LANCASF","LIGHTSRC","LIMBESS","LIMONSF","LINGAPWF","LKBWFBES","LKBWIND","LOYYANGA","LVES","MACINTYR","MACQGEN","MANILDRA","MANNUMB","MANNUMS2","METPL","METZSF","MOKOANSF","MOLONGOP","MONDO","MOORAWF","MOREEAC","MORTLSWF","MOUSF","MRNBESS","MTGELLWF","MTMERCER","MTMILLAR","MULWALSF","MUNCRKSF","MUWARRA2","MWARRA","NEMRESTR","NESBESS","NEWENGSF","NEWGEN","NEWGRWF","NPSAIL","NUMURKSF","NVTSF","OEBESS","OERARING","ORANBESS","PAPMICRO","PBLUESGA","PEAKCO","PLBESS1","PORTADL","POWRSSGA","PSF","PWRSYNC","QGCSALE1","QUORNPSF","RANGBESS","RATCHTOW","RIVEBESS","ROSSRVER","RYAN","RYEPARK","SALTCRK","SAPHWF1","SAWCML","SEBSF","SECGEN","SERDR","SHELLNEW","SHUBMASP","SITHE","SLVRTN","SMCTSV","SMFBESS","SMTHBESS","SNODE1","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SOUTHHYD","SOUTHYD2","SRSF1","STANCCWF","STANWAM1","STANWAM2","STANWELL","STARFISH","STOCKYRD","STUBB1SF","SUNRSF","SUNSPOT3","SUNTOP","TAILEM","TALL","TARALGA","TBSF","TELSTRAE","TIPSCO","TLTSFS","TRGBESS","TRUDW","ULPBESS1","UNIQLDSF","VBBHMCA3","VIOTAS","WAGGAOPS","WALGBESS","WANDOAN","WATERLWF","WDOWBESS","WDOWNS","WELLNTH","WEMENSF","WGWF","WILDCATL","WILLBESS","WINTONSF","WLWLSF1","WLWLSF2","WOLLARSF","WOODLAWN","WOOLBESS","WOOLNWF","WOOLOOGA","WROCKWF","WSUNDAY","WTAHBESS","WYALONG","WYASF","XELIO","YALLOURN","YARRANSF","YARWUN","YATSF","YESSA","ZENENGEN"],"is_categorical":true},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","examples":["-3.17","0.01","0","150"],"is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","examples":["-0.01","0.01","0","22400"],"is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","examples":["-0.76","0.02","0","22500"],"is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","examples":["-1.45","0.01","0","22600"],"is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","examples":["-0.97","0.01","0","22700"],"is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","examples":["-1.84","0.02","0","22800"],"is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 7","examples":["-0.97","0.35","0","22900"],"is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","examples":["-0.01","0.01","0","23000"],"is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","examples":["-2.64","3.24","0","23190"],"is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","examples":["46.46","2","24165.12","23200"],"is_float":true},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(500)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities","examples":["00 Initial Bid","010 Unexpected/plant limits~trapezium mgmt","01:00~A~Initial Bid","01:01~A~Initial Bid","01:02~A~Initial Bid","01:03~A~Initial Bid","01:04~A~Initial Bid","01:38~P~03:58 FCAS Availability Update","01:39~A~Initial Bid","01:40~A~Initial Bid","01:41~A~Initial Bid","020 Reduction in avail cap~ unit trip","020 Reduction in avail cap~203 plant failure","070 Reduced water avail~704 inflow chg affecting pondage levels","0900P Initial offer","10:57~F~00 Initial Bid","11:00~P~Availability statement (11:15~semi-sched as advised by O","11:21 Daily Offer","11:22 Daily Offer","11:46:08 F INITIAL BID","1245 A initial Bid SL","12:32~F~001 Primary Response to D+1 Predispatch","17:22 P ENTER A REBID REASON","17:56:33 P CHANGE IN SOC FORECAST","17:57:05 P CHANGE IN SOC FORECAST","5MS - INITIAL RESERVER TRADER DEFAULT BID","5MS - Tom Web test for DG_NEW1","A Initial Bid SL","A initial Bid SL","A: Initial Offer","ADJ BANDS LOCAL PRICE CONSTRAINT MANAGEMENT","ADJUST ASSET BREAK EVEN PRICE TO REFLECT CHANGE IN FINANCIAL POS","AEMO forecast or dispatch change.","Adj bands - chg in NSW RRP for HHE 05:00, $84 vs $80.4 at HHE 21","Adj pasa, recall - GT1-3 outage postponed. SL","Adjustment to Trapezium LOWER5MIN, LOWER60SEC, LOWER6SEC","Alumina Refinery Constraints","Ambient conditions - match bid to expected unit outputs~","Avail adj due to SOC condition SL","Avail adj due to battery capability SL","Availability Change LOWER5MIN, LOWER60SEC, RAISE5MIN, RAISE60SEC","CHANGE IN FCAS COSTS RESULTING IN REVENUE $0.00 IN THE CURRENT I","CHANGE IN FORECAST AVERAGE COMBINED REVENUE TO $0.00 FOR THE NEX","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL PRICE TO $-0.01 FOR","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL PRICE TO $-1.17 FOR","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL PRICE TO $54.73 FOR","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL PRICE TO $67.42 FOR","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL REVENUE TO $165.44 ","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL REVENUE TO $417.53 ","CHANGE IN FORECAST AVERAGE DISPATCH INTERVAL REVENUE TO $42.14 F","CHANGE IN PLANT AVAILABILITY - SCADA ISSUE SL","CHANGE IN QLD RRP PD@21:40 : PD 22:00 v PD 22:30 - SL","CP2 Testing - Revised Profile","Capability Change (PD) ENERGY","Capability Change ENERGY, LOWERREG, RAISEREG","Capability Change RAISE5MIN","Change In SOC - Update Availability","Change in Plant Availability SL.","Change in Unit State - SL","Change in avail - coms issues revised - SL","Change in avail - inverter limitations revised SL","Change in co-optimised bids for DI=0345-1000. Max delta change a","Change in forecast SOC","Change in outage schedule: Trevallyn 1&2 condition monitoring ru","Change in plant conditions","Changing portfolio conditions","DEC NSW Semi-scheduled 5PD 388MW < 30PD 397MW @ 2230 SL","Daily Bid","Daily Bid - Extension of STPASA period by one day","Daily Bid SL","Daily bid","Default Offer","Demand different from forecast: TAS","Demand different from forecast: TAS SL","Emissions -Fabric filter-SL","FCAS Enablement Update - Match Plant Conditions.","FCAS UNAVAILABLE - SL","FIRMWARE UPGRADE COMMISSIONING TESTS SL","Fan(s) Limitation","Forecasted change QLD1 RRP at 2026-09-01T00:30:00 from existing ","Forecasted change SA1 RRP at 2026-09-01T03:45:00 from existing f","Forecasted change SA1 RRP at 2026-09-01T04:05:00 from existing f","Forecasted change VIC1 RRP at 2026-09-01T03:45:00 from existing ","Forecasted change VIC1 RRP at 2026-09-01T04:00:00 from existing ","GRTS Enablement TD 01092026 - SL","HP3 testing","Heaters 5&6 OOS - SL; Generation: ROC 0405-0400;SL;","Higher SOC than expected","INC VIC DEM 5PD 5961MW > 30PD 5903MW @ 2210 SL","INITIAL BID","INITIAL BID - BLOWERING OUTPUT INFLEXIBLE TO DISPATCH PROCESS","INITIAL OFFER","INITIAL OFFER SL","Initial Bid","Initial Bid 01/09/2026","Initial Offer","Initial Offer +UNMANNED","Initial Offer for ENERGY","Initial Offer for LOWER1SEC","Initial Offer for LOWER5MIN","Initial Offer for LOWER60SEC","Initial Response to PDS SL","Initial offer","LOCAL PRICE MANAGEMENT - MANAGE DISPATCH OUTCOMES - SL","Lake level different from forecast - LI_WY_CA","Manage Unit SOC Levels - SL","Managing Available Energy - SOC MWh - AT","NSW 30MIN PD +500 Sensitivity $7.45 LOWER THAN 30MIN PD 16:00@15","NSW 30MIN PD Price $7.42 HIGHER THAN 30MIN PD 23:30@13:33 ($64.9","NSW1 5MIN PD RRP FOR 0430 ($68.54) PUBLISHED AT 0356 IS $3.59 HI","New outage requirement - DEVILS GATE - SL","P - Unexpected availability of storage (03:57)","P Initial Energy Offer","PLANT TESTING - HP3 REHEARSAL  - SL","Planned outage","Plant Conditions - Match Traps to Unit Availability SL","Plant Conditions - Match traps to mill operating range SL","Plant Testing - Commissioning Revised SL","Plant capability different to expectation: Tribute post shutdown","Predispatch Price Change","Price < forecast: VIC. PD SL","Price bands update due to new bidding strategy","Price different from forecast: VIC P30 - SL","QLD1 30MIN PD RRP FOR 0400 ($54.73) PUBLISHED AT 0331 IS $11.73 ","QLD1 30MIN PD RRP FOR 0830 ($6.85) PUBLISHED AT 0331 IS $14.92 L","QLD1 5MIN PD RRP FOR 0405 ($54.73) PUBLISHED AT 0356 IS $1.75 HI","Rebid as the forecast RRP is -0.02 $/MWh and the local price is ","Rebid due to the changes in forecast SOC","Reset to default offer","Response to PD conditions","Reviewed pre-dispatch--SL","Reviewed pre-dispatch-SL","SA 30PD change - over 01 Sep 21:30 - 02 Sep 04:00 change in Avai","SA1 30MIN PD RRP FOR 0400 ($53.18) PUBLISHED AT 0331 IS $26.53 H","SA1 30MIN PD RRP FOR 0430 ($-1.1) PUBLISHED AT 0331 IS $1.11 LOW","SA1 30MIN PD RRP FOR 1330 ($-29.86) PUBLISHED AT 0331 IS $2.41 H","SCADA OUTAGE REQUIREMENT - BID OUT FCAS","SOE approaching lower operational limits set by asset operator f","Trader error","UPDATE CAPABILITY PARAMETERS FOR CHANGE TO OUTAGE PLAN/PLANT CON","UPDATING MAX AVAILABILITY","Unexpected platform outage Lower1Sec","Unexpected platform outage Lower5Min","Unexpected platform outage Lower60Sec","Update Bid for Offer","Update trapezium availability - rebid to match SCADA or expected","Updated optimisation solution due to change in portfolio conditi","Updated price forecast","VIC1 5MIN PD RRP FOR 0420 ($0.0) PUBLISHED AT 0356 IS $0.01 LOWE","VIC1 5MIN PD RRP FOR 0430 ($0.01) PUBLISHED AT 0356 IS $0.0 LOWE","Weir Level Management - SL","response to PDS SL"]},"T1":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to synchronise in minutes (Energy Bids Only)","examples":["0","1","22"],"is_integer":true,"num_int_bits":128},"T2":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to minimum load in minutes (Energy Bids Only)","examples":["0","1","10"],"is_integer":true,"num_int_bits":128},"T3":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time at minimum load in minutes (Energy Bids Only)","examples":["0","1","52"],"is_integer":true,"num_int_bits":128},"T4":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Time to shutdown in minutes (Energy Bids Only)","examples":["0","1","11"],"is_integer":true,"num_int_bits":128},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":false,"comment":"Version No. for given offer date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDDAYOFFER_D%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":2320221,"decompressed_size_all_time":1123535690},"visibility":"Public","trigger":"Data is published daily"},"BIDDUIDDETAILS":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"BIDDUIDDETAILS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#13"],"comment":"BIDDUIDDETAILS and the associated tracking object BIDDUIDDETAILSTRK define the registration data for each ancillary service a dispatchable unit is registered to provide. The registration data is required to validate a dispatchable unit bid submitted for that ancillary service.","description":"BIDDUIDDETAILS data is public to participants.\n\nSource\n\nBIDDUIDDETAILS updates as dispatchable unit registration details are\nmodified.\n\nVolume\n\nApproximately 1000 records per year.","primary_keys":["BIDTYPE","DUID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["APD01","APD02","APS","BW01","BW02","BW03","BW04","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","DARTM1","EILDON1","EILDON2","ER01","ER02","ER03","ER04","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUTHEGA","LD01","LD02","LD03","LD04","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYA4","MACKAYGT","MCKAY1","MCKAY2","MM3","MM4","MP1","MP2","MSTUART1","MSTUART2","MURRAY","NPS","NPS1","NPS2","OAKEY1","OAKEY2","PPCCGT","PTH01","PTH02","PTH03","PUMP1","PUMP2","SHPUMP","SNOWYGJP","SNOWYP","STAN-1","STAN-2","STAN-3","STAN-4","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TUMUT3","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","UPPTUMUT","VP5","VP6","W/HOE#1","W/HOE#2","WKIEWA1","WKIEWA2","WW7","WW8","YABULU","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:30 inclusive","examples":["2001/09/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Record version number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2001/09/13 16:38:05"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXCAPACITY":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Maximum Capacity of this DUID for this BIDTYPE","examples":["5","600"],"is_integer":true,"num_int_bits":128},"MAXENABLEMENTLEVEL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Maximum Energy Output (MW) at which this ancillary service can be supplied (AS Only)","examples":["0","30","1600"],"is_integer":true,"num_int_bits":128},"MAXLOWERANGLE":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Maximum Angle at the lower end of the ancillary service profile (Degrees)","examples":["15","90"],"is_integer":true,"num_int_bits":16},"MAXUPPERANGLE":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Maximum Angle at the upper end of the ancillary service profile (Degrees)","examples":["16","90"],"is_integer":true,"num_int_bits":16},"MINENABLEMENTLEVEL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Minimum Energy Output (MW) at which this ancillary service becomes available (AS Only)","examples":["0","5","300"],"is_integer":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDDUIDDETAILS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":63950,"decompressed_size_all_time":54178330},"visibility":"Public","trigger":"When dispatchable unit registration details are modified"},"BIDDUIDDETAILSTRK":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"BIDDUIDDETAILSTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#22"],"comment":"BIDDUIDDETAILSTRK shows the tracking for the associated object BIDDUIDDETAILS. Together, BIDDUIDDETAILSTRK and BIDDUIDDETAILS define the registration data for each ancillary service a dispatchable unit is registered to provide. The registration data is required to validate a dispatchable unit bid submitted for that ancillary service.","description":"BIDDUIDDETAILSTRK data is public to participants.\n\nSource\n\nBIDDUIDDETAILSTRK updates as dispatchable unit registration details are\nmodified.\n\nVolume\n\nApproximately 200 records per year","primary_keys":["DUID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["AGLHAL","AGLSOM","ANGAS1","ANGAS2","APD01","APD02","APS","AWABAREF","BAPS","BARCALDN","BARRON-1","BARRON-2","BASTYAN","BAYNL1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BELLBAY1","BELLBAY2","BLNKTAS","BLNKVIC","BLOWERNG","BLUFF1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BROWNMT","BURRIN","BUTLERSG","BW01","BW02","BW03","BW04","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CATHROCK","CETHANA","CG1","CG2","CG3","CG4","CHALLHWF","CLEMGPWF","CLOVER","CLOVER1","CLOVER2","CLUNY","CNUNDAWF","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","CPP_3","CPP_4","CPSA","DAANDINE","DARTM1","DDPS1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DLNKNSW","DLNKQLD","DRYCGT1","DRYCGT2","DRYCGT3","EILDON1","EILDON2","ER01","ER02","ER03","ER04","FISHER","GB01","GB02","GERMCRK","GORDON","GRANGEAV","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUNNING1","GUTHEGA","HALLWF1","HALLWF2","HUMENSW","HUMEV","HVGTS","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JBUTTERS","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARYNL1","KKGTS","KPP_1","KRCCOGEN","LADBROK1","LADBROK2","LAVNORTH","LD01","LD02","LD03","LD04","LEM_WIL","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LONGFORD","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKAYGT","MACKNTSH","MCKAY1","MCKAY2","MEADOWBK","MINTARO","MM3","MM4","MOR1","MOR2","MOR3","MORANBAH","MORTLK11","MORTLK12","MP1","MP2","MPP_1","MPP_2","MRIDGE","MSTUART1","MSTUART2","MSTUART3","MTMILLAR","MURRAY","MUSSELR1","NBHWF1","NGTS","NPS","NPS1","NPS2","OAKEY1","OAKEY2","OAKLAND1","OAKYCREK","OSB-AG","OSB01","OSB02","PALOONA","PIONEER","PLAYB-AG","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","POAT110","POAT220","POR01","POR03","PPCCGT","PTH01","PTH02","PTH03","PUMP1","PUMP2","QPS1","QPS2","QPS3","QPS4","QPS5","REDBANK1","REECE1","REECE2","REMOUNT","REPULSE","ROMA_7","ROMA_8","ROWALLAN","RPCG","RT_NSW1","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUBICON","SHGEN","SHPUMP","SITHE01","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","SWANNL1","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","SWAN_E","TALWA1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TATURA01","TNPS1","TOORAWF","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TREVALLN","TRIBUTE","TUMUT3","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","TUNGATIN","TVCC201","TVPP104","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VP5","VP6","VPGS","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WATERLWF","WG01","WKIEWA1","WKIEWA2","WOODLWN1","WOOLNTH1","WPWF","WW7","WW8","YABULU","YABULU2","YAMBUKWF","YARWUN_1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:30 inclusive","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Record version number","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User that authorised record. A NULL value indicates the record is not authorised.","examples":["2008_EOY","CASSA","DAVIDGA","GAURAVS","JBEALE","JEFFP","JOHNB","LUKEB","MARKS","PETAE","RGILLETT","SATAN","TOMB"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of record authorisation. A NULL value indicates the record is not authorised.","examples":["2001/09/12 10:37:47"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2001/09/13 16:37:57"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDDUIDDETAILSTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":26045,"decompressed_size_all_time":20672670},"visibility":"Public","trigger":"When dispatchable unit registration details are modified"},"BIDOFFERFILETRK":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDOFFERFILETRK","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"BIDOFFERFILETRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#23"],"comment":"BIDOFFERFILETRK shows an audit trail of all files submitted containing ENERGY/FCAS/MNSP bid, including corrupt bids and rebids.","description":"BIDOFFERFILETRK data is confidential to the submitting participant.\n\nThe new ancillary service arrangements require availability and prices\nfor each Frequency Control Ancillary Service to be bid on a similar\nbasis to energy. Three new tables facilitate ancillary service bidding.\nThe new tables (BIDOFFERFILETRK, BIDDAYOFFER and BIDOFFERPERIOD) are\nsimilar in structure to energy bidding tables (OFFERFILETRK, DAYOFFER\nand PEROFFER). The significant differences with the new tables are.\n\n· The OFFERDATE field reflects the time the bid was loaded and this\nfield alone provides the key for versioning of bids. The VERSIONNO field\nis retained for participant use as information only.\n\n· The new tables support bids for multiple services. The BIDTYPE field\ndefines the service to which the bid applies.\n\n· There are no default bids. In the absence of a bid for a specific\nsettlement date, the latest bid submitted for a previous settlement date\napplies.\n\nSource\n\nThis data is updated as bids are processed. It includes all bids\nsubmitted including corrupt bids.\n\nVolume\n\nApproximately 100,000 records per year\n\nNote\n\nConfirmation is via CSV bid acknowledgement file","primary_keys":["OFFERDATE","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"OFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","parse_csv_as_string":true,"is_ms_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Participant agent who created the Offer"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"When the Offer was processed - synonymous with LastChanged","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"COMMENTS":{"sql_type":"VARCHAR2(1000)","pl_type":"str","mandatory":false,"comment":"A participant provided comment"},"FILENAME":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":true,"comment":"Submitted file name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REFERENCE_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A participant provided reference, which is required to be unique per submission (for a PARTICIPANTID)"},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Load status [SUCCESSFUL/CORRUPT]"},"SUBMISSION_METHOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Method by which this submission was made typically FTP, API, WEB"},"SUBMISSION_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The participant provided date/time for the submission","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TRANSACTION_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A GUID used to identify the submission transaction in AEMOs systems"}},"visibility":"Private","trigger":"As bids are processed"},"BIDOFFERPERIOD":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDOFFERPERIOD","VERSION":2},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDOFFERPERIOD","VERSION":3},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDOFFERPERIOD_SPARSE","VERSION":1},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"BIDOFFERPERIOD_SPARSE","VERSION":2},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"BIDOFFERPERIOD","VERSION":1,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#34"],"comment":"BIDOFFERPERIOD shows 5-minute period-based Energy and Ancillary Service bid data.BIDOFFERPERIOD is a child table of BIDDAYOFFER","primary_keys":["BIDTYPE","DIRECTION","DUID","OFFERDATETIME","PERIODID","TRADINGDATE"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"The type of bid, one-of ENERGY, RAISE6SEC, RAISE60SEC, RAISE5MIN, RAISEREG, LOWER6SEC, LOWER60SEC, LOWER5MIN, LOWERREG","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DIRECTION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The power flow direction to which this offer applies: GEN, LOAD or BIDIRECTIONAL","examples":["BIDIRECTIONAL"],"warnings":["Despite AEMO's documentation saying that this column is mandatory, it is missing from older files. It was added to the schema in [version 5.3](https://tech-specs.docs.public.aemo.com.au/Content/TSP_EMMSDM53_April2024/Participant_Impact.htm#NEXTDAYbids)."]},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit ID","examples":["WDBESS1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","examples":["2026/09/30 06:07:29.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period ID 1 to 288","examples":["1","288"],"is_integer":true,"num_int_bits":16},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The trading date this bid is for","examples":["2026/09/30 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BANDAVAIL1":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 1","examples":["0"],"is_float":true},"BANDAVAIL2":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 2","examples":["0"],"is_float":true},"BANDAVAIL3":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 3","examples":["0"],"is_float":true},"BANDAVAIL4":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 4","examples":["6"],"is_float":true},"BANDAVAIL5":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 5","examples":["9"],"is_float":true},"BANDAVAIL6":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 6","examples":["5"],"is_float":true},"BANDAVAIL7":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 7","examples":["5"],"is_float":true},"BANDAVAIL8":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 8","examples":["5"],"is_float":true},"BANDAVAIL9":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 9","examples":["0"],"is_float":true},"BANDAVAIL10":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 10","examples":["110"],"is_float":true},"ENABLEMENTMAX":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Energy Output (MW) at which this ancillary service can be supplied (AS Only)","examples":["35","255"],"is_float":true},"ENABLEMENTMIN":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Energy Output (MW) at which this ancillary service becomes available (AS Only)","examples":["-25","-255"],"is_float":true},"ENERGYLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy limit applying at the end of this dispatch interval in MWh. For GEN this is a lower energy limit. For LOAD this is an upper energy limit","is_float":true},"FIXEDLOAD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW (Energy bids only) A null value means no fixed load so the unit is dispatched according to bid and market","is_float":true},"HIGHBREAKPOINT":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","examples":["0","1","115"],"is_float":true},"LOWBREAKPOINT":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","examples":["-25","-255"],"is_float":true},"MAXAVAIL":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum availability for this BidType in this period","examples":["35","140"],"is_float":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Allows for future use for Energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["6"],"is_float":true},"PERIODIDTO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Period ID Ending","examples":["1","288"],"is_integer":true,"num_int_bits":16},"RAMPDOWNRATE":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for lower (Energy bids only)","examples":["2"],"is_integer":true,"num_int_bits":32},"RAMPUPRATE":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for raise (Energy bids only)","examples":["2"],"is_integer":true,"num_int_bits":32},"RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The advance notice(in hours) that a Scheduled Resource requires to achieve the PASA Availability MW for this trading interval","is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDOFFERPERIOD%23FILE64%23202609010000.zip","manifest_summary":{"max_files_per_month":64,"first_month":{"year":2021,"month":3},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17663469618,"decompressed_size_all_time":4583053157380},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The filenames of zips may not correspond to the tables. These can be mixed up with BIDPEROFFER. Check column 2 and 3 inside the CSV against `REPORT_NAME` and `REPORT_SUBTYPE` to be sure. I have already done this for you, and listed all URLs in [this metadata file](../../manifests/per_table/csv/BIDOFFERPERIOD.csv).\n","category":"filenames"}],"trigger":"Data is published whenever new bid data arrives"},"BIDPEROFFER":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"BIDPEROFFER","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#28"],"comment":"BIDPEROFFER shows period-based Energy and Ancillary Service bid data. BIDPEROFFER is a child table of BIDDAYOFFER.","description":"The new ancillary service arrangements require availability and prices\nfor each Frequency Control Ancillary Service to be bid on a similar\nbasis to energy. Three new tables facilitate ancillary service bidding.\nThe new tables (BIDOFFERFILETRK, BIDDAYOFFER and BIDPEROFFER) are\nsimilar in structure to energy bidding tables (OFFERFILETRK, DAYOFFER\nand PEROFFER). The significant differences with the new tables are:\n\n· The OFFERDATE field reflects the time the bid was loaded and this\nfield alone provides the key for versioning of bids. The VERSIONNO field\nis retained for participant use as information only.\n\n· The new tables support bids for multiple services. The BIDTYPE field\ndefines the service to which the bid applies.\n\n· There are no default bids. In the absence of a bid for a specific\nsettlement date, the latest bid submitted for a previous settlement date\napplies.\n\nBIDPEROFFER data is confidential to the submitting participant until\nmade public after 4am the next day.\n\nSource\n\nBIDPEROFFER updates as energy and ancillary service bids are processed.\nBIDPEROFFER includes all accepted energy and ancillary service bids.\n\nVolume\n\nApproximately 72,000,000 records per year","unused":true,"primary_keys":["BIDTYPE","DUID","OFFERDATE","PERIODID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["AGLHAL","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date","examples":["2021/01/21 09:57:06"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Period ID","examples":["1","48"],"is_integer":true,"num_int_bits":128},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2021/02/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BANDAVAIL1":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 1","examples":["0","29","32"],"is_integer":true,"num_int_bits":128},"BANDAVAIL2":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 2","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL3":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 3","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL4":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 4","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL5":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 5","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL6":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 6","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL7":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 7","examples":["29","60"],"is_integer":true,"num_int_bits":128},"BANDAVAIL8":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 8","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL9":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 9","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL10":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 10","examples":["163","195"],"is_integer":true,"num_int_bits":128},"ENABLEMENTMAX":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum Energy Output (MW) at which this ancillary service can be supplied (AS Only)","examples":["0"],"is_integer":true,"num_int_bits":32},"ENABLEMENTMIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum Energy Output (MW) at which this ancillary service becomes available (AS Only)","examples":["0"],"is_integer":true,"num_int_bits":32},"FIXEDLOAD":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW (Energy Bids Only) A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","examples":["0"],"is_float":true},"HIGHBREAKPOINT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","examples":["0"],"is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2021/01/21 09:57:06"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWBREAKPOINT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","examples":["0"],"is_integer":true,"num_int_bits":32},"MAXAVAIL":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum availability for this BidType in this period","examples":["174","205"],"is_float":true},"MR_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Offer amount","is_integer":true,"num_int_bits":32},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Allows for future use for energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["205"],"is_integer":true,"num_int_bits":64},"ROCDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for lower (Energy Bids Only)","examples":["12"],"is_integer":true,"num_int_bits":32},"ROCUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/min for raise (Energy Bids Only)","examples":["12"],"is_integer":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":false,"comment":"Version number of offer","examples":["1","10"],"is_integer":true,"unsigned_int":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_02/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_BIDPEROFFER_202102010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":2},"has_missing_months":true,"compressed_size_per_month":92738250,"decompressed_size_all_time":36259234510},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The filenames of zips may not correspond to the tables. These can be mixed up with BIDOFFERPERIOD. Check column 2 and 3 inside the CSV against `REPORT_NAME` and `REPORT_SUBTYPE` to be sure. I have already done this for you, and listed all URLs in [this metadata file](../../manifests/per_table/csv/BIDPEROFFER.csv).\n","category":"filenames"}],"trigger":"When energy and ancillary service bids are processed"},"BIDPEROFFER_D":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"BIDPEROFFER_D","VERSION":3},{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"BIDPEROFFER_D","VERSION":4}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#40"],"comment":"BIDPEROFFER_D shows the public summary of the energy and FCAS offers applicable in the Dispatch for the\nintervals identified. BIDPEROFFER_D is the child to BIDDAYOFFER_D.","description":"BIDPEROFFER_D is public data, so is available to all participants.\n\nSource\n\nBIDPEROFFER_D updates daily shortly after 4am.\n\nSee also BIDPEROFFER.","primary_keys":["BIDTYPE","DIRECTION","DUID","INTERVAL_DATETIME","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DIRECTION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The power flow direction to which this offer applies: GEN, LOAD or BIDIRECTIONAL","examples":["GEN","LOAD"],"warnings":["Despite AEMO's documentation saying that this column is mandatory, it is missing from older files. It was added to the schema in [version 5.3](https://tech-specs.docs.public.aemo.com.au/Content/TSP_EMMSDM53_April2024/Participant_Impact.htm#NEXTDAYbids)."]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time of the dispatch interval to which the offer applied","examples":["2026/09/01 04:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date for which the bid applied","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BANDAVAIL1":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 1","examples":["0","1","6"],"is_integer":true,"num_int_bits":128},"BANDAVAIL2":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 2","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL3":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 3","examples":["0","2","6"],"is_integer":true,"num_int_bits":128},"BANDAVAIL4":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 4","examples":["0","2","6"],"is_integer":true,"num_int_bits":128},"BANDAVAIL5":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 5","examples":["0","1","6"],"is_integer":true,"num_int_bits":128},"BANDAVAIL6":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 6","examples":["0","2","19"],"is_integer":true,"num_int_bits":128},"BANDAVAIL7":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 7","examples":["0","2","6"],"is_integer":true,"num_int_bits":128},"BANDAVAIL8":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 8","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL9":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 9","examples":["0"],"is_integer":true,"num_int_bits":128},"BANDAVAIL10":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Availability at price band 10","examples":["0","4","255"],"is_integer":true,"num_int_bits":128},"BIDSETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Market date for which the bid was submitted","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ENABLEMENTMAX":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum Energy Output (MW) at which this ancillary service can be supplied (AS Only)","is_integer":true,"num_int_bits":32},"ENABLEMENTMIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum Energy Output (MW) at which this ancillary service becomes available (AS Only)","is_integer":true,"num_int_bits":32},"ENERGYLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy limit applying at the end of this dispatch interval in MWh. For GEN this is a lower energy limit. For LOAD this is an upper energy limit","is_float":true},"FIXEDLOAD":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW (Energy Bids Only). A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","examples":["0"],"is_float":true},"HIGHBREAKPOINT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/15 10:58:18"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWBREAKPOINT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum Energy Output (MW) at which the unit can provide the full availability (MAXAVAIL) for this ancillary service (AS Only)","is_integer":true,"num_int_bits":32},"MAXAVAIL":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum availability for this BidType in this period","examples":["0","1","160"],"is_float":true},"MR_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Offer amount","is_integer":true,"num_int_bits":32},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Offer date and time","examples":["2026/08/15 10:58:18"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Allows for future use for energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["6","192"],"is_integer":true,"num_int_bits":64},"PERIODID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"The trading interval period identifier (1-288)","examples":["1","288"],"is_integer":true,"num_int_bits":128},"RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The advance notice (in hours) that a Scheduled Resource requires to achieve the PASA Availability MW for this trading interval.","examples":["1","24000"],"is_float":true},"ROCDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for lower (Energy Bids Only)","examples":["2","12"],"is_integer":true,"num_int_bits":32},"ROCUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/min for raise (Energy Bids Only)","examples":["2","12"],"is_integer":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":false,"comment":"Version number of offer","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDPEROFFER_D%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":184438295,"decompressed_size_all_time":126648065820},"visibility":"Public","trigger":"Data is published daily"},"BIDTYPES":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"BIDTYPES","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#7"],"comment":"BIDTYPES, together with the associated tracking data in BIDTYPESTRK, define a set of ancillary services with bidding parameters from a given date.\nBIDTYPES is static data describing each type of bid quantity, the number of applicable bands, how many days ahead a price lock down becomes effective and the validation rule that applies.","description":"BIDTYPES is public to participants\n\nSource\n\nBIDTYPES updates when the static data relating to an ancillary service\ntype is modified.\n\nVolume\n\nExpect modifications to be rare. Allow for approximately 20 records per\nyear.","primary_keys":["BIDTYPE","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:30 inclusive","examples":["2000/09/12 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Record version number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of this Bid Type","examples":["1 Second Lower Large Deviation FCAS","1 Second Raise Large Deviation FCAS","5 Minute Lower Large Deviation FCAS","5 Minute Raise Large Deviation FCAS","6 Second Lower Large Deviation FCAS","6 Second Raise Large Deviation FCAS","60 Second Lower Large Deviation FCAS","60 Second Raise Large Deviation FCAS","Energy to supply system demand","Lower Regulation Small Deviation FCAS","Raise Regulation Small Deviation FCAS"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2001/09/13 16:33:22"],"parse_csv_as_string":true,"is_s_datetime":true},"NUMBEROFBANDS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Number of active bands (1 to 10)","examples":["10"],"is_integer":true,"num_int_bits":16},"NUMDAYSAHEADPRICELOCKED":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Number of days prior to the Market Day when prices are locked from 12:30pm","examples":["1"],"is_integer":true,"num_int_bits":8},"SPDALIAS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Alias for this BIDTYPE used in the SPD Solver","examples":["ENOF","L1SE","L5MI","L5RE","L60S","L6SE","R1SE","R5MI","R5RE","R60S","R6SE"]},"VALIDATIONRULE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"AS\"])","mandatory":false,"comment":"ENERGY or AS validation rules to apply.","examples":null,"enums":["ENERGY","AS"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDTYPES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":755,"decompressed_size_all_time":896860},"visibility":"Public","trigger":"When the ancillary service type static data is modified"},"BIDTYPESTRK":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"BIDTYPESTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#16"],"comment":"BIDTYPESTRK, together with the associated data in BIDTYPES, define a set of ancillary services with bidding parameters from a given date.","description":"BIDTYPESTRK is public to participants\n\nSource\n\nBIDTYPESTRK updates when the static data relating to an ancillary\nservice type is modified.\n\nVolume\n\nExpect modifications to be rare. Allow for approximately 20 records per\nyear.","primary_keys":["EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:30 inclusive","examples":["2000/09/12 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Record version number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User that authorised record. A NULL value indicates the record is not authorised.","examples":["LUKEB","SPAI"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of record authorisation. A NULL value indicates the record is not authorised.","examples":["2001/09/13 16:33:22"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2001/09/13 16:33:22"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BIDTYPESTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":439,"decompressed_size_all_time":549610},"visibility":"Public","trigger":"When the ancillary service type static data is modified"},"BILLADJUSTMENTS":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#37"],"comment":"","description":"BILLADJUSTMENTS is confidential, and is available only to the relevant\nparticipant.\n\nSource\n\nAd hoc","unused":true,"primary_keys":["ADJBILLRUNNO","ADJCONTRACTYEAR","ADJWEEKNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"ADJBILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Billing run number of the new revised billing run for this adjustment","is_integer":true,"num_int_bits":16},"ADJCONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The contract year of the new revised billing run for this adjustment","is_integer":true,"num_int_bits":16},"ADJWEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Week number of the new revised billing run for this adjustment","is_integer":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADJAMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The total bill figure for the new revised billing run","is_float":true},"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERESTAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The total interest payable for this adjustment","is_float":true},"IRN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest rate applying to the new amount","is_float":true},"IRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest rate applying to the principal amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LRS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"is_float":true},"OFS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"is_float":true},"PARTICIPANTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant type Generator/Customer"},"PREVAMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Prior account","is_float":true},"PRS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"is_float":true}},"visibility":"Private","trigger":"Ad hoc"},"BILLINGAPCCOMPENSATION":{"package":"BILLING_RUN","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#240"],"comment":"BILLINGAPCCOMPENSATION shows Administered Price Cap (APC) compensation amounts for the billing period. Data is for each participant by region.","description":"Updated with each billing run","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"APCCOMPENSATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"APC Compensation","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to BILLING_APC_COMPENSATION","category":"related_tables"}],"trigger":"Updated when a billing run is posted"},"BILLINGAPCRECOVERY":{"package":"BILLING_RUN","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#249"],"comment":"BILLINGAPCRECOVERY shows the Administered Price Cap (APC) Recovery for the billing period. Data is for each participant by region.","description":"Source\n\nObsolete; was updated weekly with each billing run.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"APCRECOVERY":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":false,"comment":"APC Recovery amount for week","is_integer":true,"num_int_bits":64},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to BILLING_APC_RECOVERY","category":"related_tables"}],"trigger":"Updated when a billing run is posted"},"BILLINGASPAYMENTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"ASPAYMENTS","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#258"],"comment":"BILLINGASPAYMENTS shows Ancillary Service payments for each billing period by each of the Ancillary Service types for each participant’s connection points.","description":"BILLINGASPAYMENTS data is confidential to relevant participant.\n\nSource\n\nUpdated with each billing run.\n\nVolume\n\nThe volume is according to the number of Transmission ConnectionPointIDs\na Participant may have subject to ancillary payment per billrunno. An\nindicative maximum is approximately 20 records are inserted per\nbillrunno, or about 220 records inserted per week.","primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week No","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"AGC Payments","is_float":true},"AVAILABILITY_REACTIVE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment","is_float":true},"AVAILABILITY_REACTIVE_RBT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment rebate","is_float":true},"FCASCOMP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Compensation Payments","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The latest date and time that a file was updated or inserted","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOADSHED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Payments","is_float":true},"LOWER1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount for the very fast lower service","is_float":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 Minute Payment","is_float":true},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 Sec Payments","is_float":true},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 Sec Payments","is_float":true},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 Minute Regulation Payment","is_float":true},"RAISE1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount for the very fast raise service","is_float":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 Minute Payment","is_float":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 Sec Payments","is_float":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 Sec Payments","is_float":true},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 Minute Regulation Payment","is_float":true},"REACTIVEPOWER":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Payments","is_float":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RGUL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator unit Loading Payments","is_float":true},"RGUU":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator Unit Unloading Payments","is_float":true},"SYSTEMRESTART":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"System Restart Payments","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Updated when a billing run is posted"},"BILLINGASRECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"ASRECOVERY","VERSION":10}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#267","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15_1.htm"],"comment":"BILLINGASRECOVERY shows participant charges for Ancillary Services for the billing period. This view shows the billing amounts for Ancillary Service Recovery.","description":"BILLINGASRECOVERY data is confidential to relevant participant.\n\nSource\n\nUpdated with each billing run.\n\nVolume\n\nApproximately 5 records are inserted per billrunno, or about 55 records\ninserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week No","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"AGC Recovery - Not used since circa 2000","is_float":true},"AGC_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"AGC Recovery for Generator","is_float":true},"AVAILABILITY_REACTIVE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment recovery amount (customer).. NULL for Billing Week post the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Availability Payment Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Availability Payment Recovery Amount for the Participant and Region from ASOE MWh Portion. For Pre-IESS Settlement dates this column will have NULL value. For Pre-IESS Settlement dates this column will have NULL value.","is_float":true},"AVAILABILITY_REACTIVE_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment recovery amount (Generator).. NULL for Billing Week post the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_RBT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment rebate recovery amount (customer).. NULL for Billing Week post the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_RBT_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Availability Rebate Payment Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_RBT_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Availability Rebate Payment Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"AVAILABILITY_REACTIVE_RBT_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total availability payment rebate recovery amount (Generator).. NULL for Billing Week post the IESS rule effective date","is_float":true},"FCASCOMP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Compensation Recovery - Not used since circa 2000","is_float":true},"FCASCOMP_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Compensation Recovery for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The latest date and time a file was updated/inserted","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOADSHED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Recovery. Post-IESS the value in this column only represent the Testing Payment Recovery from Customers. 0 if no testing payment exists.","is_float":true},"LOADSHED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Load Shed Ancillary Service Recovery Amount for for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOADSHED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Load Shed Ancillary Service Recovery Amount for for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOADSHED_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Recovery for Generator. Post-IESS the value in this column only represent the Testing Payment Recovery from Generators. 0 if no testing payment exists.","is_float":true},"LOWER1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer recovery amount for the very fast lower service. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER1SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower1Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER1SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower1Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER1SEC_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator recovery amount for the very fast lower service. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 5 Minute service attributable to customer connection points. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER5MIN_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower5Min FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER5MIN_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower5Min FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER5MIN_GEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 5 Minute service attributable to generator connection points. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 Sec Recovery. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER6SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower6Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER6SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower6Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date value.","is_float":true},"LOWER6SEC_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 Sec Recovery for Generator. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 Sec Recovery. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWER60SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower60Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER60SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower60Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWER60SEC_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 Sec Recovery for Generator. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWERREG":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Post-IESS the amount in this column represent only the Lower Regulation FCAS MPF Recovery Amount from Customer and Generator Connection Point MPFs, no Residue Amounts are added to this column value. For Billing Weeks past FPP Rule Effective Date this column is not used. Always show 0.","is_float":true},"LOWERREG_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Regulation FCAS Residue Recovery Amount using ACE MWh values. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"LOWERREG_GEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower Regulation service attributable to generator connection points. NULL for Billing Week post the IESS rule effective date","is_float":true},"LOWERREG_UNUSED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Unused Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_UNUSED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Unused ACE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_UNUSED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Unused ASOE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_UNUSED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"LOWERREG_UNUSED_ACE + LOWERREG_UNUSED_ASOE","is_float":true},"LOWERREG_USED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Used Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_USED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Used ACE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_USED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Lower Reg Service Used ASOE Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"LOWERREG_USED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"LOWERREG_USED_ACE + LOWERREG_USED_ASOE","is_float":true},"RAISE1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer recovery amount for the very fast raise service. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE1SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise1Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE1SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise1Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE1SEC_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator recovery amount for the very fast raise service. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 5 Minute service attributable to customer connection points. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE5MIN_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise5Min FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE5MIN_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise5Min FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE5MIN_GEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 5 Minute service attributable to generator connection points. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 Sec Recovery. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE6SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise6Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE6SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise6Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE6SEC_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 Sec Recovery for Generator. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 Sec Recovery. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISE60SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise60Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE60SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise60Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISE60SEC_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 Sec Recovery for Generator. NULL for Billing Week post the IESS rule effective date","is_float":true},"RAISEREG":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Post-IESS the amount in this column represent only the Raise Regulation FCAS MPF Recovery Amount from Customer and Generator Connection Point MPFs, no Residue Amounts are added to this column value. For Billing Weeks past FPP Rule Effective Date this column is not used. Always show 0.","is_float":true},"RAISEREG_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Regulation FCAS Residue Recovery Amount using ACE MWh values. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RAISEREG_GEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise Regulation service attributable to generator connection points. NULL for Billing Week post the IESS rule effective date. NULL for Billing Week post the IESS rule effective date.","is_float":true},"RAISEREG_UNUSED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Unused Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_UNUSED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Unused ACE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_UNUSED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Unused ASOE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_UNUSED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RAISEREG_UNUSED_ACE + RAISEREG_UNUSED_ASOE","is_float":true},"RAISEREG_USED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Used Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_USED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Used ACE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_USED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Raise Reg Service Used ASOE Residual Amount for the Billing Week. This column will be NULL for Billing Week Prior to FPP Rule Effective Date","is_float":true},"RAISEREG_USED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RAISEREG_USED_ACE + RAISEREG_USED_ASOE","is_float":true},"REACTIVEPOWER":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Recovery. Post-IESS the value in this column only represent the Testing Payment Recovery from Customers. 0 if no testing payment exists.","is_float":true},"REACTIVEPOWER_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Recovery Amount for for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REACTIVEPOWER_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Reactive Power Ancillary Service Recovery Amount for for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REACTIVEPOWER_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Recovery for Generator. Post-IESS the value in this column only represent the Testing Payment Recovery from Generators. 0 if no testing payment exists.","is_float":true},"RGUL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator Unit Loading Recovery - Not used since December 2001","is_float":true},"RGUL_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator unit Loading Recovery for. Generator - Not used since December 2001","is_float":true},"RGUU":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator Unit Unloading Recovery - Not used since December 2001","is_float":true},"RGUU_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Rapid Generator Unit Unloading Recovery for Generator - Not used since December 2001","is_float":true},"SYSTEMRESTART":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"System Restart Recovery. Post-IESS the value in this column only represent the Testing Payment Recovery from Customers. 0 if no testing payment exists","is_float":true},"SYSTEMRESTART_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The System Restart Ancillary Service Recovery Amount for for the Participant and Region from ACE MWh Portion. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"SYSTEMRESTART_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The System Restart Ancillary Service Recovery Amount for for the Participant and Region from ASOE MWh Portion. NULL for Billing Week prior to the IESS rule effective date,","is_float":true},"SYSTEMRESTART_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"System Restart Recovery for Generator. Post-IESS the value in this column only represent the Testing Payment Recovery from Generators. 0 if no testing payment exists.","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run","pagination":["Elec15_1.htm"]},"BILLINGCALENDAR":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"BILLINGCALENDAR","VERSION":3},{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"BILLINGCALENDAR","VERSION":4}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#1"],"comment":"BILLINGCALENDAR sets out the billing calendar for the year, with week number 1 starting on 1 January. BILLINGCALENDAR advises preliminary and final statement posting date and corresponding settlement for each billing week.","description":"BILLINGCALENDAR is public data, and is available to all participants.\n\nSource\n\nInfrequently, only when inserting billing weeks for a future\ncontractyear.\n\nVolume\n\n52-53 records inserted per contractyear","primary_keys":["CONTRACTYEAR","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["1998","2018"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","examples":["1","53"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"End Date of week","examples":["1998/01/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"FINALSTATEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Final Statement Date","examples":["1998/01/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/10/28 14:06:27"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Payment Date","examples":["1998/01/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PRELIMINARYSTATEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Preliminary Statement Date","examples":["1998/01/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REV0_FINAL_ATTACH_WEEK":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The FINAL Week where the R0 will be attached."},"REV0_PAYMENT_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The payment date of the FINAL week in REV0_FINAL_ATTACH_WEEK.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REV1_FINAL_ATTACH_WEEK":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The FINAL Week where the R1 will be attached."},"REV1_PAYMENT_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The payment date of the FINAL week in REV1_FINAL_ATTACH_WEEK.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REV2_FINAL_ATTACH_WEEK":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The FINAL Week where the R2 will be attached."},"REV2_PAYMENT_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The payment date of the FINAL week in REV2_FINAL_ATTACH_WEEK.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REVISION0_STATEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Revision 0 Statement Date for the billing week.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REVISION1_STATEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Revision 1 Statement Date for the billing week.","examples":["2012/05/22 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REVISION2_STATEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Revision 2 Statement Date for the billing week.","examples":["2012/08/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REVISIONS_ATTACHED_TO_FINAL":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"The list of Revisions that are attached in the FINAL Statement of the week"},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Start Date of week","examples":["1997/12/28 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGCALENDAR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":34479,"decompressed_size_all_time":36183160},"visibility":"Public","trigger":"When inserting billing weeks for a future AEMO Contract Year"},"BILLINGCPDATA":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"CPDATA","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#114"],"comment":"BILLINGCPDATA shows energy quantity and $ value purchased per participant connection point. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, BILLING_ENERGY_TRANSACTIONS AND BILLING_ENERGY_GENSET_DETAIL replace BILLINGCPDATA.","description":"BILLINGCPDATA data is confidential to relevant participant.\n\nSource\n\nPopulated by the posting of a billing run, being several times each\nweek.\n\nVolume\n\nThe number of records depends on the number of Transmission\nConnectionPointIDs a participant may use to purchase energy. An\nindicative maximum is approximately 150 records per billrunno, or about\n1,500 records inserted per week.","unused":true,"primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONTRACTYEAR","MDA","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique connection point identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"relevant MDA for this connection point."},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AFE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjusted Gross Energy for this Market Customer FRMP and TNI in the Billing run, excluding any UFEA component.","is_float":true},"AGE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjusted Gross Energy for this Market Customer FRMP and TNI in the trading interval. This will include the UFEA value once financial settlement of UFE commences with GS.","is_float":true},"AGGREGATEENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate energy purchased/sold by customer, in MWh, plus UFEA. When GS commences, this includes the UFEA amount in the settlement runs.","is_float":true},"DME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ME- for all NMIs at this Market Customer FRMP and TNI in the Billing run.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PURCHASEDENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The energy consumed at the connection point by the participant in this billing run","is_float":true},"PURCHASES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The Purchase column has the dollar value of the Energy Purchased rather than Aggregate Energy Dollar","is_float":true},"SALES":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total cost of energy sold at the connection point by the participant in this billing run","is_float":true},"SOLDENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy sold at the connection point by the participant in this billing run","is_float":true},"UFEA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Share of UFE allocated to this FRMP and TNI in the Billing run.","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run (several times each week)"},"BILLINGCPSUM":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#125"],"comment":"BILLINGCPSUM shows adjustments for a billing run by participant.","description":"BILLINGCPSUM data is confidential to the relevant participant.\n\nSource\n\nWeekly update with billing run.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","PARTICIPANTTYPE","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PARTICIPANTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant type Generator/Customer"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADJUSTEDAMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjusted amount billed","is_float":true},"ADJUSTMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Run no of adjustment","is_integer":true,"num_int_bits":16},"ADJUSTMENTWEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Week no of adjustment","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREVIOUSAMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Previous amount billed","is_float":true}},"visibility":"Private","trigger":"Weekly with the billing run"},"BILLINGCUSTEXCESSGEN":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#136"],"comment":"BILLINGCUSTEXCESSGEN shows excess generation payments for each participant cutover.","description":"Source\n\nObsolete; was updated with relevant settlement runs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Half hourly trading period that excess generation is for","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXCESSGENPAYMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment by Customer for Excess Generation","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"BILLINGDAYTRK":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DAYTRK","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#276"],"comment":"BILLINGDAYTRK is key for matching settlement versions with billing runs. BILLINGDAYTRK displays the billrunnos per billing week, and the settlement version numbers per settlement day comprising the billrunno.","description":"BILLINGDAYTRK is public data, and is available to all participants.\n\nSource\n\nBILLINGDAYTRK is populated by the posting of a billing run, being\nseveral times each week.\n\nVolume\n\nEach billing run inserts approximately 7 records, being about 77 records\nper week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","SETTLEMENTDATE","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","examples":["8","996"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar Settlement Date contained in the billing run.","examples":["2026/02/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","examples":["6","40"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/24 09:31:10"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Settlement run number used for each settlement date in that billing run.","examples":["1","11"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGDAYTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1739,"decompressed_size_all_time":1968520},"visibility":"Public","trigger":"After posting of a billing run (several times each week)"},"BILLINGEXCESSGEN":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#145"],"comment":"BILLINGEXCESSGEN shows the excess generation cost by period for each participant.","description":"Source\n\nObsolete; was updated weekly with each billing run.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement interval within the settlement date (1-48) starting at 00:30","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar settlement date record becomes effective","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXCESSENERGYCOST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost of excess energy attributed to this customer","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"BILLINGFEES":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"FEES","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#285"],"comment":"BILLINGFEES presents pool fees applied to the statement, per billing run.","description":"BILLINGFEES data is confidential to the relevant participant.\n\nSource\n\nBILLINGFEES is populated by the posting of a billing run, being several\ntimes each week.\n\nVolume\n\nThe number of records varies according to the number of pool fee types\nthe participant may be subject to. An indicative maximum is about 13\nrecords inserted per billrunno or 143 records inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","MARKETFEEID","PARTICIPANTCATEGORYID","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Market fee identifier"},"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"The participant category pertaining to the market fee recovery. Corresponds to the PARTICIPANTCATEGORYID column of the SETMARKETFEES table."},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy, in MWh","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Market fee rate","is_float":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Fee in $","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run (several times each week)"},"BILLINGFINANCIALADJUSTMENTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"FINANCIALADJUSTMENTS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#296"],"comment":"BILLINGFINANCIALADJUSTMENTS contains any manual adjustments included in the billing run.","description":"BILLINGFINANCIALADJUSTMENTS data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGFINANCIALADJUSTMENTS is populated by the posting of a billing\nrun, being several times each week. The insertion of a manual adjustment\nin a billing run is infrequent.\n\nVolume\n\nInfrequent and, if included in a billing run, low volume. An indicative\nmaximum is 15 records inserted.","primary_keys":["ADJUSTMENTITEM","BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"ADJUSTMENTITEM":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":true,"comment":"Description of the adjustment being made"},"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of the manual adjustment line item","is_float":true},"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"The BAS classification of the manual adjustment line item."},"FINANCIALCODE":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The GL financial code of the manual adjustment line item. Used internally by AEMO systems.","is_integer":true,"num_int_bits":64},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not Used","unused":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not Used","unused":true,"is_float":true}},"visibility":"Private","trigger":"After posting of a billing run (several times each week)"},"BILLINGGENDATA":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"GENDATA","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#156"],"comment":"BILLINGGENDATA shows the total energy sold and purchased per participant transmission connection point for a billing period. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, BILLING_ENERGY_TRANSACTIONS AND BILLING_ENERGY_GENSET_DETAIL replace BILLINGGENDATA.","description":"BILLINGGENDATA data is confidential to the the relevant participant.\n\nSource\n\nBILLINGGENDATA is populated by the posting of a billing run, being\nseveral times each week.\n\nVolume\n\nThe number of records depends on the number of transmission\nConnectionPointIDs a Participant may have sold energy from per\nbillrunno. An indicative maximum is approximately 15 records inserted\nper billrunno, or about 165 records inserted per week.\n\nBILLINGGENDATA is confidential to the the relevant participant.","unused":true,"primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGGREGATEENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate energy sold, in MWh","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"not populated","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Metering Data Agent supplying data"},"PURCHASEDENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of energy purchased in MWh","is_float":true},"PURCHASES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"$ outgoing","is_float":true},"SALES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"$ income","is_float":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"not populated","is_categorical":true}},"visibility":"Private","trigger":"After posting of a billing run (several times each week)"},"BILLINGINTERRESIDUES":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"INTERRESIDUES","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#305"],"comment":"BILLINGINTERRESIDUES shows interregion residues payable to NSP.","description":"Source\n\nObsolete, was weekly with billing run.","primary_keys":["BILLRUNNO","CONTRACTYEAR","INTERCONNECTORID","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for an interconnector which joins two regions.","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ALLOCATION":{"sql_type":"NUMBER(6,3)","pl_type":"pl.Float64","mandatory":false,"comment":"May not be necessary","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount NSP is paid for Inter-Regional Residues","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"May not be necessary","is_float":true}},"visibility":"Private"},"BILLINGINTERVENTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#167"],"comment":"BILLINGINTERVENTION shows billing intervention recovery details.","description":"BILLINGINTERVENTION is confidential to the relevant participant.\n\nSource\n\nUpdated when reserve trading occurs in a billing run, such as during an\nAdministered Price Cap event. View is empty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETINTERVENTION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Intervention Amounts paid to Generator for Market Recovery for region","is_float":true},"TOTALINTERVENTION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Intervention Amounts paid to Generator","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLINGINTERVENTIONREGION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#176"],"comment":"BILLINGINTERVENTIONREGION shows recovery charges for region intervention.","description":"BILLINGINTERVENTIONREGION is confidential to the relevant participant.\n\nSource\n\nBILLINGINTERVENTIONREGION is updated with relevant settlement runs, such\nas containing an Administered Price Cap. BILLINGINTERVENTIONREGION is\nempty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONINTERVENTION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for that region","is_float":true}},"visibility":"Private","trigger":"When there are recovery charges for region intervention"},"BILLINGINTRARESIDUES":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"INTRARESIDUES","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#314"],"comment":"BILLINGINTRARESIDUES shows intra-region settlement residue details for each Transmission Network Service Provider participant by region.","description":"BILLINGINTRARESIDUES is confidential to the relevant participant.\n\nSource\n\nBILLINGINTRARESIDUES is populated by the posting of a billing run, being\nseveral times each week.\n\nVolume\n\nAn indicative maximum is two records inserted per billing run, or 22\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ALLOCATION":{"sql_type":"NUMBER(6,3)","pl_type":"pl.Float64","mandatory":false,"comment":"TNSP allocation","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount TNSP is paid for Intra-Regional Residues","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total $ residue amount for the region","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINGIRAUCSURPLUS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRAUCSURPLUS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#323"],"comment":"BILLINGIRAUCSURPLUS supports the Settlements Residue Auction, by showing the weekly billing Interconnector Residue (IR) payments as calculated for each bill run for Network Service Providers (NSPs) from the amount not auctioned.","description":"Source\n\nObsolete\n\nVolume\n\nThis view contains a maximum of 30, 000 records per year.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year (calendar year)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"ADJUSTMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjustment allocated to participant","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Residue Contract Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"TOTALRESIDUES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residues allocated to participant","is_float":true}},"visibility":"Private"},"BILLINGIRAUCSURPLUSSUM":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRAUCSURPLUSSUM","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#332"],"comment":"BILLINGIRAUCSURPLUSSUM contains Auction fees and Settlements Residue Auction distribution that may arise from unpurchased auction units that accrue to Transmission Network Service Providers.","description":"BILLINGIRAUCSURPLUSSUM is confidential to the relevant participant.\n\nSource\n\nBILLINGIRAUCSURPLUSSUM is populated by the posting of a billing run\nwhere there are unpurchased auction units.\n\nVolume\n\nAn indicative maximum is eight records inserted per billing run, or 88\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","QUARTER","RESIDUEYEAR","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contracted Year (calendar year)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Residue Contract Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACTUALPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net payment to participant, including auction fees","is_float":true},"AUCTIONFEES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total auction fees payable in this week (negative amount). If AUCTIONFEES + AUCTIONFEES_GST >= TOTALSURPLUS then ACTUALPAYMENT is zero","is_float":true},"AUCTIONFEES_GST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST amount on the auction fees, always being zero.","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEGATIVE_RESIDUES":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Negative residues in the billing week for this participant in the SRA Year/Quarter","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residue amount allocated to participant","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP.","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run where there are unpurchased auction units"},"BILLINGIRFM":{"package":"BILLING_RUN","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#341"],"comment":"BILLINGIRFM shows billing amounts associated with Industrial Relations Forced Majeure events for each participant.","description":"BILLINGIRFM is confidential to the relevant participant.\n\nSource\n\nBILLINGIRFM is updated with each billing run as required.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique bill run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week number starting 1 Jan each year.","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"IRFMPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Industrial Relations Forced Majeure payment for the billing period.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated in the billing run as required"},"BILLINGIRNSPSURPLUS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRNSPSURPLUS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#350"],"comment":"BILLINGIRNSPSURPLUS supports the Settlements Residue Auction (SRA), by showing the weekly billing Interconnector Residue (IR) payments as calculated for each bill run for Transmission Network Service Providers (TNSP) from the amount paid by participants (i.e. derogated amounts).","description":"BILLINGIRNSPSURPLUS data is confidential to the relevant participant.\n\nSource\n\nBILLINGIRNSPSURPLUS updates in a billing run where any derogated\nSettlement Residue Auction purchase flows to a TNSP.\n\nVolume\n\nBILLINGIRNSPSURPLUS contains a maximum of 30, 000 records per year.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"ADJUSTMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjustment allocated to participant","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Residue Contract Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"TOTALRESIDUES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residues allocated to participant","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run where derogated payments apply"},"BILLINGIRNSPSURPLUSSUM":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRNSPSURPLUSSUM","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#359"],"comment":"BILLINGIRNSPSURPLUSSUM contains derogated payments made to TNSPs arising from the Settlements Residue Auction process.","description":"BILLINGIRNSPSURPLUSSUM data is confidential to the relevant participant.\n\nSource\n\nBILLINGIRNSPSURPLUSSUM is populated by the posting of a billing run\nwhere derogated payments apply.\n\nVolume\n\nAn indicative maximum is two records inserted per billing run, or 22\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","QUARTER","RESIDUEYEAR","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year (calendar year)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUCTIONFEES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is 0.","is_float":true},"AUCTIONFEES_GST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST amount on the auction fees, always being zero.","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residue amount allocated to participant","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP.","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run where the participant has purchased auction units relating to that billing run"},"BILLINGIRPARTSURPLUS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRPARTSURPLUS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#368"],"comment":"BILLINGIRPARTSURPLUS supports the Settlements Residue Auction, by showing the weekly billing SRA distribution to Auction participants by Contract Identifier.","description":"BILLINGIRPARTSURPLUS data is confidential to the relevant participant.\n\nSource\n\nBILLINGIRPARTSURPLUS is populated by the posting of a billing run where\nthe participant has purchased auction units relating to that billing\nrun.\n\nVolume\n\nAn indicative maximum is 64 records inserted per billing run, or 700\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year (calendar year)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"ACTUALPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net actual payment to participant, including auction fees","is_float":true},"ADJUSTMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjustment allocated to participant","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Residue Contract Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"TOTALRESIDUES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residues allocated to participant","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINGIRPARTSURPLUSSUM":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRPARTSURPLUSSUM","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#377"],"comment":"BILLINGIRPARTSURPLUSSUM supports the Settlements Residue Auction, by showing the weekly billing SRA distribution and associated fees to Auction participants.","description":"BILLINGIRPARTSURPLUSSUM data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGIRPARTSURPLUSSUM is populated by the posting of a billing run\nwhere the participant has purchased auction units relating to that\nbilling run.\n\nVolume\n\nAn indicative maximum is 16 records inserted per billing run, or 166\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","QUARTER","RESIDUEYEAR","WEEKNO"],"indexes":[["RESIDUEYEAR","QUARTER"],["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The sequential number of a billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year (calendar year)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"QUARTER":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Residue Contract Quarter","is_integer":true,"num_int_bits":8},"RESIDUEYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Year of the Residue Contract; may differ from the calendar year at week 1.","is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACTUALPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net payment to participant, including auction fees","is_float":true},"AUCTIONFEES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total auction fees payable in this week (negative amount). If AUCTIONFEES + AUCTIONFEES_GST >= TOTALSURPLUS then ACTUALPAYMENT is zero.","is_float":true},"AUCTIONFEES_GST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST amount on the auction fees, always being zero.","is_float":true},"AUCTIONFEES_TOTALGROSS_ADJ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted total Auction fees for the Directional Interconnector. Calculated as the amount of the total fees due from the SRA Auction Participant, pro-rated based on the total surplus for each Directional Interconnector the SRA Auction Participant contracted.","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total residue amount allocated to participant","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP.","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINGPRIORADJUSTMENTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"PRIORADJUSTMENTS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#388"],"comment":"BILLINGPRIORADJUSTMENTS sets out prior period adjustments and associated interest inserted in subsequent Final Statements arising from Revision Statement postings.","description":"BILLINGPRIORADJUSTMENTS data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGPRIORADJUSTMENTS is populated on the posting of a Final billing\nrun only.\n\nVolume\n\nApproximately two records inserted per week.\n\nNote\n\nActual adjustment payable is ADJAMOUNT - PERAMOUNT + INTEREST AMOUNT.","primary_keys":["ADJBILLRUNNO","ADJCONTRACTYEAR","ADJWEEKNO","BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID","LASTCHANGED"]],"columns":{"ADJBILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Bill run number of the posted revision statement inserted to the Final Statement","is_integer":true,"num_int_bits":16},"ADJCONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"ContractYear of the posted revision statement inserted to the Final Statement","is_integer":true,"num_int_bits":16},"ADJWEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"WeekNo of the posted revision statement inserted to the Final Statement","is_integer":true,"num_int_bits":16},"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement year.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant ID","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement week number.","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADJAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjusted amount.","is_float":true},"INTERESTAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest amount.","is_float":true},"IRN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest rate applied to the revision adjustment","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREVAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Statement total of the previous posted revision statement inserted to the Final Statement.","is_float":true},"IRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"unused; always null","unused":true,"is_float":true},"IRSR_ADJAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"unused; always null","unused":true,"is_float":true},"IRSR_INTERESTAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"unused; always null","unused":true,"is_float":true},"IRSR_PREVAMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"unused; always null","unused":true,"is_float":true}},"visibility":"Private","trigger":"After posting of a final billing run"},"BILLINGREALLOC":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"REALLOC","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#399"],"comment":"BILLINGREALLOC shows reallocation contract values in each billing run, where participants have used reallocations.","description":"BILLINGREALLOC data is confidential to the relevant participant.\n\nSource\n\nBILLINGREALLOC is populated by the posting of a billing run.\n\nVolume\n\nAn indicative maximum is two records inserted per billing run, or 22\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","COUNTERPARTY","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COUNTERPARTY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Participant who is the counter party to this contract"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Value billed on this contract","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINGREALLOC_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"REALLOC_DETAIL","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#410"],"comment":"Billing Reallocation Data aggregated by REALLOCATIONID for each billing run over the billing week.","description":"The BILLINGREALLOC_DETAIL table that will give a breakdown of the\nreallocations that form part of that billing run. This assists\nparticipants in their settlement reconciliation process.\n\n \n\nPrivate data\n\nVolume max 100 rows per day","primary_keys":["BILLRUNNO","CONTRACTYEAR","COUNTERPARTY","PARTICIPANTID","REALLOCATIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"BILLING RUN NO","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"BILLING CONTRACTYEAR","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COUNTERPARTY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"REALLOCATION COUNTERPARTY PARTICIPANTID"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"REALLOCATION PARTICIPANTID","is_categorical":true},"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"REALLOCATIONID"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"BILLING WEEKNO","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"DATETIME WHEN RECORD SAVED","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"REALLOCATION VALUE","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINGREGIONEXPORTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"REGIONEXPORTS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#419"],"comment":"BILLINGREGIONEXPORTS sets out the region summary table of overall energy exported to and from each region for each billing run.","description":"BILLINGREGIONEXPORTS data is public, and is available to all\nparticipants.\n\nSource\n\nBILLINGREGIONEXPORTS is populated by the posting of a billing run.\n\nVolume\n\nEight records inserted per billing run, or 88 records inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","EXPORTTO","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","examples":["8","996"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXPORTTO":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Region exported to","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","examples":["6","40"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"MWh Energy value exported","examples":["-0.342083","0","-127644.567044"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/24 09:31:10"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Interregional residue","examples":["-2.02714","3.95266","0","10434354.20159"],"is_float":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Value of energy exported","examples":["-17.73596","2.55878","0","175544.03615"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGREGIONEXPORTS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":10510,"decompressed_size_all_time":11005420},"visibility":"Public","trigger":"Posting of a billing run"},"BILLINGREGIONFIGURES":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"REGIONFIGURES","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#428"],"comment":"BILLINGREGIONFIGURES sets out additional summary region details including ancillary service amounts for each billing run.","description":"BILLINGREGIONFIGURES is public data, and is available to all\nparticipants.\n\nSource\n\nBILLINGREGIONFIGURES is populated by the posting of a billing run.\n\nVolume\n\nFive records inserted per billing run, or 55 records inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","examples":["8","996"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","examples":["6","40"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADMINPRICECOMPO":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"ASPAYMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Ancillary service payments in $","examples":["10709.593581","4546059.739655"],"is_float":true},"ENERGYOUT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"MWh Energy output in the region during the billing period","examples":["18027.713817","1426411.018829"],"is_float":true},"ENERGYPURCHASED":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"MWh Amount of energy purchased in region during billing period","examples":["-25215.307183","-1547503.984546"],"is_float":true},"EXCESSGEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"INTCOMPO":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/24 09:31:10"],"parse_csv_as_string":true,"is_s_datetime":true},"POOLFEES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"RESERVETRADING":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"This field is populated with 0","examples":["0"],"is_float":true},"SETTSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Intraregional residues in $","examples":["-478.946774","223.698571","-1537548.317357","705358.907709"],"is_float":true},"VALUEOUT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Value of energy output in region during billing period","examples":["-90579.606082","41935.243236","-2237740.457136","200648458.851785"],"is_float":true},"VALUEPURCHASED":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Value of energy purchased during billing period","examples":["-14746.581902","7306.610966","-219463695.651948","2196477.544428"],"is_float":true},"WDRSQ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR Settlement Quantity Capped in MWh","examples":["0"],"is_float":true},"WDRTA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR transaction amount in $","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGREGIONFIGURES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":15084,"decompressed_size_all_time":19693360},"visibility":"Public","trigger":"Posting of a billing run"},"BILLINGREGIONIMPORTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"REGIONIMPORTS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#437"],"comment":"BILLINGREGIONIMPORTS sets out the region summary table of overall energy imported to and from each region for each billing run.","description":"BILLINGREGIONIMPORTS is public data, and is available to all\nparticipants.\n\nSource\n\nBILLINGREGIONIMPORTS is populated by the posting of a billing run.\n\nVolume\n\nEight records inserted per billing run, or 88 records inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","IMPORTFROM","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","examples":["8","996"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"IMPORTFROM":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Region energy imported from","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","examples":["6","40"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of energy imported","examples":["0.075633","0","118322.630254"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/24 09:31:10"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Populated with 0","examples":["0"],"is_float":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interregional residue","examples":["-2.02714","3.95266","0","10434354.20159"],"is_float":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Value of energy imported","examples":["-20.53552","6.97491","0","17192168.54328"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGREGIONIMPORTS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":10341,"decompressed_size_all_time":10184130},"visibility":"Public","trigger":"Posting of a billing run"},"BILLINGRESERVERECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#185"],"comment":"BILLINGRESERVERECOVERY shows Market Reserve recovery details for each participant in a bill run.","description":"BILLINGRESERVERECOVERY data is Confidential to participant.\n\nSource\n\nBILLINGRESERVERECOVERY updates when reserve trading occurs in a billing\nrun, such as during an Administered Price Cap event.\nBILLINGRESERVERECOVERY is empty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETRESERVE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount Retailer pays for Reserve Trader Contracts with Market Recovery","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLINGRESERVEREGIONRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#194"],"comment":"BILLINGRESERVEREGIONRECOVERY shows Billing Region Reserve region recovery details for each participant (by region).","description":"BILLINGRESERVEREGIONRECOVERY data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGRESERVEREGIONRECOVERY updates when reserve trading occurs in a\nbilling run, such as during an Administered Price Cap event. View is\nempty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier for region recovery.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONRESERVE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount Retailer pays for Reserve Trader Contracts with Region Recovery","is_float":true}},"visibility":"Private","trigger":"After posting a billing run (preliminary, final, or revised)"},"BILLINGRESERVETRADER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#203"],"comment":"BILLINGRESERVETRADER shows Billing Market Reserve TRADER payment details to Generators.","description":"BILLINGRESERVETRADER data is Confidential to the relevant participant.\n\nSource\n\nBILLINGRESERVETRADER updates when reserve trading occurs in a billing\nrun, such as during an Administered Price Cap event. View is empty until\nsuch an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETRESERVE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve Trader Amounts paid to Generator for Market Recovery","is_float":true},"TOTALCAPDIFFERENCE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"is_float":true},"TOTALRESERVE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Reserve Trader Amounts paid to Generator","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLINGRESERVETRADERREGION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#212"],"comment":"BILLINGRESERVETRADERREGION shows Billing Region Reserve Trader payment details.","description":"BILLINGRESERVETRADERREGION data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGRESERVETRADERREGION updates when reserve trading occurs in a\nbilling run, such as during an Administered Price Cap event. View is\nempty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONRESERVE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve Trader Amounts paid to Generator for Region Recovery","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLINGRUNTRK":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"RUNTRK","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#446"],"comment":"BILLINGRUNTRK identifies the Statement type (i.e. Status of PRELIM, FINAL, REVISE) and date of the BillRunNo posted, per WeekNo. This provides a further extension of tracking data from the BILLINGDAYTRK table.","description":"BILLINGRUNTRK is public data, and is available to all participants.\n\nSource\n\nBILLINGRUNTRK is populated by the posting of a billing run.\n\nVolume\n\nAn indicative maximum is one record inserted per billing run, or 11\nrecords inserted per week.","primary_keys":["BILLRUNNO","CONTRACTYEAR","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Sequential run number","examples":["8","996"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the run","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week number of the run","examples":["6","40"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADJ_CLEARED":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag","examples":["Y","N"],"value_map":{"Y":1,"N":0},"is_boolean":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"null, since not used"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"null, since not used","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 01:23:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENTPOSTBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Who posted the payment"},"PAYMENTPOSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"When the payment was posted","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"POSTBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Who posted the results","examples":["ACOADE","AJENSZ","BPHILIPS","JKOUNIS","YCHEN2"]},"POSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"When the results were posted","examples":["2026/09/01 11:40:13"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RECEIPTPOSTBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"null, since not used"},"RECEIPTPOSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"null, since not used","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REVISIONINDEX":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Revision Run Type","is_integer":true,"num_int_bits":16},"SHORTFALL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment shortfall amount","is_float":true},"STATUS":{"sql_type":"VARCHAR2(6)","pl_type":"str","mandatory":false,"comment":"The billing run type, PRELIM, FINAL, REVISE or INTERIM","examples":["DAILY","FINAL","PRELIM","REVISE"]},"MAKEUP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not Used","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLINGRUNTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1141,"decompressed_size_all_time":1489260},"visibility":"Public","trigger":"Posting of a billing run"},"BILLINGSMELTERREDUCTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#221"],"comment":"BILLINGSMELTERREDUCTION shows the smelter reduction payment (only applies to participants with Victorian customer connection points).","description":"BILLINGSMELTERREDUCTION data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINGSMELTERREDUCTION is populated by the posting of a billing run\nwhere the participant has Victorian customer connectionpoints.\n\nVolume\n\nOne record inserted per billing run, or 11 records inserted per week.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["PARTICIPANTID"],["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":128},"CONTRACTYEAR":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":128},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PCSD":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Victorian Demand as defined by Code Chapter 9 definitions","is_float":true},"RA1":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment","is_float":true},"RA2":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment","is_float":true},"RATE1":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Rate in $/MWh","is_float":true},"RATE2":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Rate in $/MWh","is_float":true},"TE":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Tabulated Energy","is_float":true}},"visibility":"Private","trigger":"After posting a billing run"},"BILLING_APC_COMPENSATION":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"APC_COMPENSATION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#1"],"comment":"Billing result table for APC compensation payments.","description":"Updated with each billing run","primary_keys":["APEVENTID","BILLRUNNO","CLAIMID","CONTRACTYEAR","WEEKNO"],"columns":{"APEVENTID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Id","is_integer":true,"num_int_bits":32},"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLAIMID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Claim Id","is_integer":true,"num_int_bits":32},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount to the participant","is_float":true},"COMPENSATION_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Type of Administered Price Compensation Claim. Valid values: DIRECT_COST, OTHER_COST"},"EVENT_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Administered Price Event Type. Valid values: ENERGY, FCAS, BOTH"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time of last changed record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant identifier","is_categorical":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to BILLINGAPCCOMPENSATION","category":"related_tables"}],"trigger":"Generated when a billing run is posted"},"BILLING_APC_RECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"APC_RECOVERY","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#8"],"comment":"Billing result table for recovery of APC compensation payments","description":"Updated with each billing run","primary_keys":["APEVENTID","BILLRUNNO","CLAIMID","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"APEVENTID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Id","is_integer":true,"num_int_bits":32},"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLAIMID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Claim Id","is_integer":true,"num_int_bits":32},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ELIGIBILITY_END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The ending half hourly interval for the eligibility period for recovery of APC Payment","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ELIGIBILITY_START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The starting half hourly interval for the eligibility period for recovery of APC Payment","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time of last changed record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANT_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value of the participant from the Eligibility Interval used for the APC Recovery Calculation. If the Billing Week is prior to the IESS rule effective date, then value is Null.","is_float":true},"PARTICIPANT_DEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The participant demand in the cost recovery region","is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount attributable to the participant in that region","is_float":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value of the Region from the Eligibility Interval used for the APC Recovery Calculation. This is the sum of the ACE MWh of all the participants in that recovery. If the Billing Week is prior to the IESS rule effective date, then value is Null.","is_float":true},"REGION_DEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of demand of all participants in the cost recovery region (Region Sum)","is_float":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to BILLINGAPCRECOVERY","category":"related_tables"}],"trigger":"Populated by the posting of a billing run, being several times each week"},"BILLING_CASHSEC_INTEREST_PAY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"CASHSEC_INTEREST_PAY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#15"],"comment":"Indicates the amount of cash security interest payment the participant receives","primary_keys":["BILLRUNNO","CASH_SECURITY_ID","CONTRACTYEAR","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CASH_SECURITY_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Cash Security ID"},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"ContractYear/ WeekNo/ BillRunNo for the Interest payment","is_integer":true,"unsigned_int":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CASH_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Dollar amount of the cash security","is_float":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The interest account ID for calculating the interest payment"},"INTEREST_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest amount calculated for the billing week","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique identifier for the Participant lodging the cash security","is_categorical":true}},"visibility":"Private","trigger":"On change"},"BILLING_CO2E_PUBLICATION":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"BILLING_CO2E_PUBLICATION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#21"],"comment":"Carbon Dioxide Intensity Index publication table","primary_keys":["CONTRACTYEAR","REGIONID","SETTLEMENTDATE","WEEKNO"],"indexes":[["CONTRACTYEAR","WEEKNO","SETTLEMENTDATE","REGIONID"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Enum([\"QLD1\", \"NSW1\", \"VIC1\", \"SA1\", \"TAS1\", \"NEM\"])","mandatory":true,"comment":"Region identifier","examples":null,"warnings":["Unlike most tables, this column contains \"NEM\" as a region ID, referring to the sum of the per-region values for the same time interval."],"enums":["QLD1","NSW1","VIC1","SA1","TAS1","NEM"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date (Calendar)","examples":["2026/08/23 00:00:00"],"parse_csv_as_string":true,"is_date":true},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week no","examples":["35","39"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run no","examples":["8","9"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"GENERATOREMISSIONS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total generator emissions for region (Co2-e)","examples":["21.36186398","0","340845.61362994"],"is_float":true},"INTENSITYINDEX":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Carbon Dioxide Intensity index for region (CO2-e/MWh)","examples":["0.001","0","0.8837"],"is_float":true},"SENTOUTENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total sent out energy for region (MWh)","examples":["17554.22132762","562987.99393157"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLING_CO2E_PUBLICATION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":5741,"decompressed_size_all_time":18525670},"visibility":"Public","trigger":"Generated when a billing run is posted"},"BILLING_CO2E_PUBLICATION_TRK":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"BILLING_CO2E_PUBLICATION_TRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#29"],"comment":"Carbon Dioxide Intensity Index publication tracking table","primary_keys":["CONTRACTYEAR","WEEKNO"],"indexes":[["CONTRACTYEAR","WEEKNO"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week no","examples":["35","39"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":false,"comment":"Billing run no","examples":["8","9"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date time","examples":["2026/09/02 10:34:36"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLING_CO2E_PUBLICATION_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":477,"decompressed_size_all_time":614420},"visibility":"Public","trigger":"Generated when a billing run is posted"},"BILLING_CSP_DEROGATION_AMOUNT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#48"],"comment":"CSP derogation amounts with respect to participant allocated payment","description":"Source\n\nBILLING_CSP_DEROGATION_AMOUNT is populated by the posting of a billing\nrun.\n\nVolume\n\nAn indicative maximum is one record inserted per billing run, or 11\nrecords inserted per week.","unused":true,"primary_keys":["AMOUNT_ID","BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"AMOUNT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Amount identifier represented as a string, from \"ta1\" through to \"ta6\" (or \"ta8\" for a lymmco derogation result)"},"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant allocated the payment amount for the derogation","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Derogation amount associated with the amount identifier","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Generated when a billing run is posted"},"BILLING_DAILY_ENERGY_SUMMARY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DAILY_ENERGY_SUMMARY","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#37"],"comment":"Billing result table containing daily summary data for customer and generator energy amounts","description":"BILLING_DAILY_ENERGY_SUMMARY data is confidential to the relevant\nparticipant.\n\nSource\n\nPopulated by the posting of a billing run.\n\nVolume\n\nApproximately 20 records per billrunno.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","SETTLEMENTDATE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ACE Amount for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ACE MWh value for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ASOE Amount for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ASOE MWh value for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of CE MWh value for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"CUSTOMER_ENERGY_PURCHASED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer energy amount purchased on this settlement day by the participant in the region. NULL for Billing Week post the IESS rule effective date.","is_float":true},"GENERATOR_ENERGY_PURCHASED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator energy amount purchased on this settlement day by the participant in the region. NULL for Billing Week post the IESS rule effective date.","is_float":true},"GENERATOR_ENERGY_SOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator energy amount sold on this settlement day by the participant in the region. NULL for Billing Week post the IESS rule effective date.","is_float":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of Total Amount for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of Total MWh value for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of UFEA MWh value for the Participant and region for the Settlement Date. NULL for Billing Week prior to the IESS rule effective date","is_float":true}},"visibility":"Private","trigger":"Populated by the posting of a billing run, being several times each week"},"BILLING_DIRECTION_RECONCILIATN":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#57"],"comment":"Billing reconciliation result table for both provisional and final directions using the FPP methodology (prior to 1st July 2011)","description":"Source\n\nBILLING_DIRECTION_RECONCILIATN is populated by the posting of a billing\nrun.\n\nVolume\n\nOne record inserted per direction per billing run, or 11 records\ninserted per week. Presently","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","DIRECTION_ID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Direction identifier"},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week no","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Direction compensation amount","is_float":true},"CRA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Direction compensation recovery amount","is_float":true},"DIRECTION_DESC":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Direction description"},"DIRECTION_END_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Direction end date time","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DIRECTION_START_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Direction start date time","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"GENERATOR_PERC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Direction compensation recovery amount percentage breakdown among generators","is_float":true},"INDEPENDENT_EXPERT_FEE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Independent expert fee charged on calculating direction compensation amount","is_float":true},"INTEREST_AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Interest occurred on direction compensation amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MKT_CUSTOMER_PERC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Direction compensation recovery amount percentage breakdown among customers","is_float":true},"NEM_FEE_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Fixed settlement fee identifier for direction purpose"},"NEM_FIXED_FEE_AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed settlement fee for participants between direction start and end date","is_float":true}},"visibility":"Public","trigger":"Generated when a billing run is posted"},"BILLING_DIRECTION_RECON_OTHER":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"BILLING_DIRECTION_RECON_OTHER","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#74"],"comment":"Billing reconciliation result table for both provisional and final directions","primary_keys":["BILLRUNNO","CONTRACTYEAR","DIRECTION_ID","REGIONID","WEEKNO"],"indexes":[["CONTRACTYEAR","WEEKNO","BILLRUNNO","DIRECTION_ID","REGIONID"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run no","examples":["13","15"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Direction identifier","examples":["20260417.D0001","20260506.D0001","20260514.D0001","20260515.D0001","20260802.D0001","20260802.D0002","20260808.D0001","20260809.D0001","20260818.D0001","20260822.D0001","20260823.D0001","20260823.D0002","20260829.D0001"]},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week no","examples":["16","35"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The final compensation amount for the direction. The same value for all regions","examples":["2164.606668","0","90818.046689"],"is_float":true},"CRA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total recovery amount for the direction. The same value for all regions","examples":["2164.606668","0","90818.046689"],"is_float":true},"DIRECTION_DESC":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Direction description","examples":["Direction issued in SA refer to market notices 141104 & 141108","Direction issued in SA refer to market notices 144049 & 144052","Direction issued in SA refer to market notices 144079 & 144081","Direction issued in SA refer to market notices 144086 & 144089","Direction issued in SA refer to market notices 144706 & 144715","Direction issued in SA refer to market notices 144781 & 144783","Directions issued in SA refer to market notices 144815 & 144818","Directions issued in SA refer to market notices 144908 & 144910","Directions issued in SA refer to market notices 144946 & 144950"]},"DIRECTION_END_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Settlement day on which the direction ends. The same value for all regions","examples":["2026/04/17 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DIRECTION_END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Dispatch interval in which the direction ends. The same value for all regions","examples":["2026/04/17 16:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DIRECTION_SERVICE_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The Direction Service ID associated with the Direction Type ID. Eg For FCAS Direction Type, Direction Service could be any contingency service.","examples":["ENERGY"]},"DIRECTION_START_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Settlement day on which the direction starts","examples":["2026/04/17 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DIRECTION_START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Dispatch interval in which the direction starts. The same value for all regions","examples":["2026/04/17 09:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DIRECTION_TYPE_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The service for which the direction occurred (ENERGY, ANCILLARY, NON_ENERGY_NON_AS, etc)","examples":["ENERGY"]},"INDEPENDENT_EXPERT_FEE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The independent expert fee amount for the direction. The same value for all regions","examples":["0"],"is_float":true},"INTEREST_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The interest amount calculated on the final compensation amount for the direction. The same value for all regions","examples":["0"],"is_float":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ACE MWh value for the Region over the duration of the direction. NULL for Billing Week prior to the IESS rule effective date","examples":["-770.482325","-239395.89709155"],"is_float":true},"REGION_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sum of ASOE MWh value for the Region over the duration of the direction. NULL for Billing Week prior to the IESS rule effective date","examples":["785.96506877","208118.42521528"],"is_float":true},"REGIONAL_BENEFIT_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The regional benefit factor allocated to this region for the direction","examples":["0","1"],"is_float":true},"REGIONAL_CUSTOMER_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total customer energy for this region, over the duration of the direction. NULL for Billing Week post the IESS rule effective date.","is_float":true},"REGIONAL_GENERATOR_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total generator energy for this region, over the duration of the direction. NULL for Billing Week post the IESS rule effective date.","is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLING_DIRECTION_RECON_OTHER%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":2764,"decompressed_size_all_time":2892460},"visibility":"Public","trigger":"Populated by the posting of a billing run, being several times each week"},"BILLING_DIR_FINAL_AMOUNT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DIR_FINAL_AMOUNT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#44"],"comment":"The Billing Final Directions Payment Amount for Directed/Affected/Eligible participants","primary_keys":["BILLRUNNO","COMPENSATION_TYPE","CONTRACTYEAR","DIRECTION_ID","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Type, Directed_Comp, Affected_Comp, Eligible_Comp."},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Direction Unique Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Participant ID","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"FINAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Final Payment Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVISIONAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Provisional Payment Amount","is_float":true}},"visibility":"Private"},"BILLING_DIR_FINAL_RECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DIR_FINAL_RECOVERY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#50"],"comment":"The Billing Final Directions Recovery Amount for the participants","primary_keys":["BILLRUNNO","CONTRACTYEAR","DIRECTION_ID","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Direction Unique Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Participant ID","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CRA_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Compensation Recovery Amount","is_float":true},"FINAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Final Recovery Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVISIONAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Provisional Recovery Amount","is_float":true}},"visibility":"Private"},"BILLING_DIR_PROV_AMOUNT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DIR_PROV_AMOUNT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#56"],"comment":"The Billing Provisional Directions Payment Amount for Directed/Affected/Eligible participants","primary_keys":["BILLRUNNO","COMPENSATION_TYPE","CONTRACTYEAR","DIRECTION_ID","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Type, Directed_Comp, Affected_Comp, Eligible_Comp"},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Direction Unique Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Participant ID","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Payment Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"BILLING_DIR_PROV_RECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DIR_PROV_RECOVERY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#62"],"comment":"The Billing Provisional Directions Recovery Amount for the participants","primary_keys":["BILLRUNNO","CONTRACTYEAR","DIRECTION_ID","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Direction Unique Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Participant ID","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CRA_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Compensation Recovery Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Recovery Amount","is_float":true}},"visibility":"Private"},"BILLING_DIR_RECOVERY_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"DIR_RECOVERY_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#68"],"comment":"The Billing Directions Recovery Details for the participants","primary_keys":["BILLRUNNO","CONTRACTYEAR","DIRECTION_ID","PARTICIPANTCATEGORYID","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DIRECTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Direction Unique Identifier"},"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Participant Category for recovery Customer/Generator /SmallGen"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Direction Payment Participant ID","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region ID for the recovery","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXCLUDED_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy Value (Scheduled Loads) that is excluded","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Direction Recovery Amount","is_float":true},"RECOVERY_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy Value used for the Recovery","is_float":true},"REGION_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Energy at the Region ID","is_float":true}},"visibility":"Private"},"BILLING_EFTSHORTFALL_AMOUNT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"EFTSHORTFALL_AMOUNT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#82"],"comment":"The billing shortfall run amounts","description":"BILLING_EFTSHORTFALL_AMOUNT data is confidential, and is available only\nto the relevant participant.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing week run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant affected by the shortfall calculation","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing week no","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPANY_NET_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NET energy for the Company ID associated with the Participant ID used in the shortfall calculation","is_float":true},"COMPANY_SHORTFALL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The shortfall amount for the Company ID associated with the Participant ID used in the shortfall calculation","is_float":true},"PARTICIPANT_NET_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The participant NET energy used in shortfall calculation","is_float":true},"SHORTFALL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The market shortfall amount","is_float":true},"SHORTFALL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant shortfall amount","is_float":true},"SHORTFALL_COMPANY_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The Company ID associated with the Participant ID used in the shortfall calculation"}},"visibility":"Private","trigger":"Authorisation of a billing shortfall run"},"BILLING_EFTSHORTFALL_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"EFTSHORTFALL_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#89"],"comment":"The Billing Shortfall Run Amount details","description":"BILLING_EFTSHORTFALL_DETAIL data is confidential, and is available only\nto the relevant participant.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","TRANSACTION_TYPE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing week run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant affected by the shortfall calculation","is_categorical":true},"TRANSACTION_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The transaction type details associated with the shortfall calculation"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The shortfall affected billing week no","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount for each transaction type","is_float":true}},"visibility":"Private","trigger":"Authorisation of a billing shortfall run"},"BILLING_ENERGY_GENSET_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"ENERGY_GENSET_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#96"],"comment":"The Billing Energy Genset report contains the Genset Energy detail summary for the Billing Week data","primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONTRACTYEAR","DUID","GENSETID","METERID","PARTICIPANTID","REGIONID","STATIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Connection Point associated with the DUID","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The DUID for the meter associated with the GensetId","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The GensetId for the Meter Id received","is_categorical":true},"METERID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Meter ID Identifier (NMI)"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id for the Connection Point associated with the DUID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The StationId identifier associated with the GensetId","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Week No","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy Dollar Amount for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy Dollar Amount for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy for the Meter Id . Energy received in the meter reads (DLF Adjusted) in that Billing Week","is_float":true},"DME_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The DME MWh for that Connection Point for the Participant Id in that Billing Week. This is the MWh value that is used for the UFEA Allocation","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed date time for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Amount(ACE_Amount + ASOE_Amount) for that Connection Point for the Participant Id in that Billing Week","is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total MWh(ACE_MWh + ASOE_MWh) for that Connection Point for the Participant Id in that Billing Week","is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The UFEA Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_ENERGY_TRANSACTIONS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"ENERGY_TRANSACTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#108"],"comment":"The Billing Energy Transactions is the summary of the Settlement Energy Transactions that has the ACE and ASOE MWh and Dollar values that is used for the Statement","primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The ConnectionPoint Id for the Billing Aggregation for the Participant Id.","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy Dollar Amount for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy Dollar Amount for that Connection Point for the Participant Id in that Billing Week","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true},"DME_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The DME MWh for that Connection Point for the Participant Id in that Billing Week. This is the MWh value that is used for the UFEA Allocation.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed date time for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Amount(ACE_Amount + ASOE_Amount) for that Connection Point for the Participant Id in that Billing Week","is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total MWh(ACE_MWh + ASOE_MWh) for that Connection Point for the Participant Id in that Billing Week","is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The UFEA Energy MWh Consumed for that Connection Point for the Participant Id in that Billing Week","is_float":true}},"visibility":"Private"},"BILLING_ENERGY_TRAN_SAPS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"ENERGY_TRAN_SAPS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#102"],"comment":"The SAP Billing Transaction Details for the Participants","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","TNI","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The SAP Participant ID","is_categorical":true},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The SAPS Connection Point ID"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONSUMED_ENERGY_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Cost of the Consumed Energy","is_float":true},"CONSUMED_ENERGY_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy MWh Consumed for that TNI for the Participant Id in that Billing Week","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last datetime record is updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The Region ID associated with the TNI","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SENTOUT_ENERGY_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Cost of the Sent Out Energy","is_float":true},"SENTOUT_ENERGY_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy MWh Sent Out for the TNI for the Participant Id in that Billing Week","is_float":true}},"visibility":"Private"},"BILLING_FCAS_REG_AMT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"FCAS_REG_AMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#114"],"comment":"This report show the summary of the Billing run FCAS Regulation Amounts incl default amounts.","primary_keys":["BILLRUNNO","CONNECTIONPOINTID","CONSTRAINTID","CONTRACTYEAR","PARTICIPANTID","REGIONID","UNITID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The ConnectionPointId from Settlement Results for the UnitId","is_categorical":true},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Reg Constraint Id","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The UnitId for which a FPP Factor is assigned","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType for the Constraint Id","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP Amount for the Participant and the Unit","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Lastchanged datetime of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"UNUSED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Regulation Unused Amount for the Participant and the Unit","is_float":true},"USED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FCAS Regulation Used Amount for the Participant and the Unit","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_FCAS_REG_RESIDAMT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"FCAS_REG_RESIDAMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#120"],"comment":"This report show the summary of the Billing run FCAS Regulation Residual Amounts incl default amounts","primary_keys":["BILLRUNNO","CONSTRAINTID","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Reg Constraint Id","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh used for the Residual Calculation for the Participant","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ASOE MWh used for the Residual Calculation of the Participant","is_float":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType for the Constraint Id","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ACE Portion Amount for the Billing Week","is_float":true},"FPP_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ASOE Portion Amount for the Billing Week","is_float":true},"FPP_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP Residual Amount for the Billing Week","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Lastchanged datetime of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ACE_MWH + ASOE_MWH","is_float":true},"UNUSED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused ACE Portion Amount for the Billing Week","is_float":true},"UNUSED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused ASOE Portion Amount for the Billing Week","is_float":true},"UNUSED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Residual Amount for the Billing Week","is_float":true},"USED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used ACE Portion Amount for the Billing Week","is_float":true},"USED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used ASOE Portion Amount for the Billing Week","is_float":true},"USED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used Residual Amount for the Billing Week","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_FPP":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"FPP","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#126"],"comment":"This report show the summary of the Billing run FPP Amounts for the week","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Lastchanged datetime of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERREG_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Reg Service FPP ACE Residual Amount for the Participant and the Region for the Billing Week","is_float":true},"LOWERREG_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Reg Service FPP Amount for the Participant and the Region for the Billing Week","is_float":true},"LOWERREG_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Reg Service FPP ASOE Residual Amount for the Participant and the Region for the Billing Week","is_float":true},"LOWERREG_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of LOWERREG_ACE_AMOUNT + LOWERREG_ASOE_AMOUNT","is_float":true},"RAISEREG_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Reg Service FPP ACE Residual Amount for the Participant and the Region for the Billing Week","is_float":true},"RAISEREG_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Reg Service FPP Amount for the Participant and the Region for the Billing Week","is_float":true},"RAISEREG_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Reg Service FPP ASOE Residual Amount for the Participant and the Region for the Billing Week","is_float":true},"RAISEREG_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RAISEREG_ACE_AMOUNT + RAISEREG_ASOE_AMOUNT","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_GST_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"GST_DETAIL","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#132"],"comment":"BILLING_GST_DETAIL shows the BAS class, GST_Exclusive and GST amount (if any) attributable to a participant for each transaction type.","description":"BILLING_GST_DETAIL data is confidential to NSP participants.\n\nSource\n\nPopulated by the posting of a billing run.\n\nVolume\n\nApproximately 20 records are inserted per billrunno, or about 220\nrecords inserted per week.","primary_keys":["BAS_CLASS","BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","TRANSACTION_TYPE","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The BAS classification that the transaction type belongs to."},"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"TRANSACTION_TYPE":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"The transaction type (e.g. CUSTOMER_ENERGY_PURCHASES)"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"GST_AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST amount for this transaction type.","is_float":true},"GST_EXCLUSIVE_AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST exclusive amount paid by/to the participant to/by AEMO for this transaction type.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Generated when a billing run is posted"},"BILLING_GST_SUMMARY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"GST_SUMMARY","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#141"],"comment":"BILLING_GST_SUMMARY shows the GST_Exclusive and GST amount (if any) attributable to a participant for each BAS class.","description":"BILLING_GST_SUMMARY data is confidential to NSP participants.\n\nSource\n\nPopulated by the posting of a billing run.\n\nVolume\n\nApproximately 5 records are inserted per billrunno, or about 55 records\ninserted per week.","primary_keys":["BAS_CLASS","BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The BAS classification"},"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"GST_AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST amount for this BAS classification.","is_float":true},"GST_EXCLUSIVE_AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST exclusive amount paid by/to the participant to/by AEMO for this BAS classification.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Generated when a billing run is posted"},"BILLING_IRSR_NSP_ALLOCATION":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"IRSR_NSP_ALLOCATION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#150"],"comment":"The report is used to show the participants the negative residue amount to TNSP based on regional share","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"TNSP Participant Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Amount based on regional share","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_MR_PAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#66"],"comment":"BILLING_MR_PAYMENT shows aggregate payments on a dispatchable unit/MR Event basis for accepted MR capacity","description":"BILLING_MR_PAYMENT data is confidential, and is available only to the\nrelevant participant.\n\nSource\n\nAd hoc - MR events only.\n\nVolume\n\n3500 rows per year","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","DUID","MR_DATE","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for DUID / MNSP LinkID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Date of Mandatory Restriction event; Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount by AEMO","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Participant identifier","is_categorical":true}},"visibility":"Private","trigger":"Ad hoc, when there is a MR event"},"BILLING_MR_RECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#75"],"comment":"BILLING_MR_RECOVERY shows aggregate recovery charges on a dispatchable unit / MR Event basis for spot market income from dispatch of MR capacity.","description":"BILLING_MR_RECOVERY data is confidential, and is available only to the\nrelevant participant.\n\nSource\n\nAd hoc - MR events only.\n\nVolume\n\n3500 rows per year","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","DUID","MR_DATE","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for DUID / MNSP LinkID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Date of Mandatory Restriction event; Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount to AEMO","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Participant identifier","is_categorical":true}},"visibility":"Private","trigger":"Ad hoc, when there is a MR event"},"BILLING_MR_SHORTFALL":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#84"],"comment":"BILLING_MR_SHORTFALL shows aggregate MR shortfall payments (or recovery charges) to each participant in the region for the MR event.","description":"BILLING_MR_SHORTFALL data is confidential, and is available only to the\nrelevant participant.\n\nSource\n\nAd hoc - MR events only.\n\nVolume\n\n400 rows per year.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","MR_DATE","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Date of Mandatory Restriction event; Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Participant Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted gross energy for the market customer in the restricted region for the duration of the mandatory restriction event (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RSA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Restriction Shortfall amount payable to AEMO for a mandatory restriction period","is_float":true}},"visibility":"Private","trigger":"Ad hoc, when there is a MR event"},"BILLING_MR_SUMMARY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#93"],"comment":"BILLING_MR_SUMMARY shows aggregate payment/recovery and shortfall figures for an MR Event.","description":"BILLING_MR_SUMMARY data is public to all participants.\n\nSource\n\nAd hoc - MR events only.\n\nVolume\n\n200 rows per year.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","MR_DATE","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Contract Year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Date of Mandatory Restriction event; Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing Week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AAGE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The aggregate of then adjusted gross energy of all the market customer in the restricted region for the duration of the mandatory restriction period (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTAL_PAYMENTS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Total payments by AEMO","is_float":true},"TOTAL_RECOVERY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Total payments to AEMO","is_float":true},"TOTAL_RSA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Restriction Shortfall Amount","is_float":true}},"visibility":"Public","trigger":"Ad hoc, when there is a MR event"},"BILLING_NMAS_MANUAL_PAYMENT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_MANUAL_PAYMENT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#156"],"comment":"This report contains the NMAS Manual Weekly Payments that are uploaded by the Settlement Business Team. Amounts in this table are not calculated by the Settlement System.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","DUID","PARTICIPANTID","PAYMENTTYPE","SERVICETYPE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Contract ID.","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The DUID associated with the Contract Payment.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Contract Participant Id.","is_categorical":true},"PAYMENTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Payment Type associated with the Service like Availability, Usage, Enablement, Energy Revenue, Test, ADHOC and so on."},"SERVICETYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Service Types (INERTIA, SYSTEM STRENGTH, TYPE1, TYPE2 and so on)."},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENTAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS Contract Manual Payment for the Payment Type.","is_float":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The Contract Region Id.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_NMAS_MANUAL_RECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_MANUAL_RECOVERY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#162"],"comment":"This report shows the summary of the Billing NMAS Recovery Amounts. This table will have recovery data for manual payments for System Security Services.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","PARTICIPANTID","PAYMENTTYPE","REGIONID","SERVICETYPE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing RunNo","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Contract ID.","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing Contract Year.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Contract Participant Id.","is_categorical":true},"PAYMENTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Payment Type associated with the Service like Availability, Usage, Enablement, Energy Revenue, Test, ADHOC and so on."},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICETYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Service Types (INERTIA, SYSTEM STRENGTH, TYPE1, TYPE2 and so on)."},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Billing WeekNo","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANT_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Consumed Energy in MWh.","is_float":true},"PARTICIPANT_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Sent Out Energy in MWh.","is_float":true},"PAYMENTAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS Contract Manual Payment for the Payment Type.","is_float":true},"RECOVERYAMOUNT_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery Amount on ACE portion ($).","is_float":true},"RECOVERYAMOUNT_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery Amount on ASOE portion ($).","is_float":true},"RECOVERYENDDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Recovery End Date and Time for the Payment Calculation.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RECOVERYSTARTDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Recovery Start Date and Time for the Payment Calculation.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Consumed Energy in MWh.","is_float":true},"REGION_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Sent Out Energy in MWh.","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"BILLING_NMAS_TST_PAYMENTS":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_TST_PAYMENTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#168"],"comment":"BILLING_NMAS_TEST_PAYMENTS publish the NSCAS/SRAS Testing Payments data for a posted billing week. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","PARTICIPANTID","SERVICE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The current Billing RunNo for the week","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS Contract Id","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1 January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant from whom the amount is recovered","is_categorical":true},"SERVICE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":true,"comment":"The type of NSCAS service. Current value values are:\n- REACTIVE\n- LOADSHED"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1 January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Testing Payment Amount to recover","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLING_NMAS_TST_RECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_TST_RECOVERY","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#174"],"comment":"BILLING_NMAS_TEST_RECOVERY sets out the recovery of NMAS testing payments This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","PARTICIPANTID","REGIONID","SERVICE","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The current Billing RunNo for the week","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS Contract Id","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1 January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant from whom the amount is recovered","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region from where the amount is recovered","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":true,"comment":"The type of NSCAS service. Current value values are:\n- REACTIVE\n- LOADSHED\n- RESTART"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1 January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_PORTION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Portion of ACE MWh Value used in the Recovery Calculation. . NULL for Billing Week prior to the IESS rule effective date","is_float":true},"ASOE_PORTION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Portion of ASOE MWh Value used in the Recovery Calculation (100 - ACE_Portion). . NULL for Billing Week prior to the IESS rule effective date","is_float":true},"CUSTOMER_PROPORTION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Customer Proportion for recovery amount in Percent","is_float":true},"GENERATOR_PROPORTION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Generator Proportion for recovery amount in Percent (100-Customer Portion)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Updated date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEM_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NEM energy in MWh for the recovery period","is_float":true},"NEM_GENERATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NEM Generation for the recovery period","is_float":true},"PARTICIPANT_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant ACE MWh Value used in the Recovery of the Testing Payment Amount if the service is recovered from ACE. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"PARTICIPANT_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant ASOE MWh Value used in the Recovery of the Testing Payment Amount if the service is recovered from ASOE. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"PARTICIPANT_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant energy in MWh for the recovery period","is_float":true},"PARTICIPANT_GENERATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant Generation for the recovery period","is_float":true},"RBF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Benefitting Factor for the RegionId","is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total recovery amount for the billing week, being the sum of the customer and generator proportions for the PARTICIPANTID in REGIONID and sum of RecoveryAmount_ACE and RecoveryAmount_ASOE.","is_float":true},"RECOVERY_END_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Recovery End Date for the Testing Payment Calculation","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RECOVERY_START_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Recovery Start Date for the Testing Payment Calculation","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RECOVERYAMOUNT_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant Recovery Amount based on ACE MWh Value if the service is recovered from ACE . NULL for Billing Week prior to the IESS rule effective date","is_float":true},"RECOVERYAMOUNT_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant Recovery Amount based on ASOE MWh Value if the service is recovered from ASOE . NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region ACE MWh Value used in the Recovery of the Testing Payment Amount if the service is recovered from ACE. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REGION_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region ASOE MWh Value used in the Recovery of the Testing Payment Amount if the service is recovered from ASOE. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REGION_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RegionId energy in MWh for the recovery period","is_float":true},"TEST_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Testing Payment Amount to recover from all benefitting regions","is_float":true}},"visibility":"Private","trigger":"Populated by the posting of a billing run, being several times each week"},"BILLING_NMAS_TST_RECVRY_RBF":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_TST_RECVRY_RBF","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#182"],"comment":"BILLING_NMAS_TEST_RECVRY_RBF sets out the NSCAS/SRAS Testing Payment recovery data for the posted billing week.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","REGIONID","SERVICE","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The current Billing RunNo for the week","examples":["13","16"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS Contract Id","examples":["7MYU0SMLK","AFFKU29Q@","CQMYNR1T7","DZT8GAXWG","FH4QC1TWR","SYM$HM01P","U3TBB7W5Y","WDYQ5WN82","Y#931LJ8C"],"is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1 January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region from where the amount is recovered","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":true,"comment":"The type of NSCAS service. Current value values are:\n- REACTIVE\n- LOADSHED","examples":["REACTIVE","RESTART"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1 January","examples":["6","20"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Updated date and time","examples":["2026/08/24 09:31:10"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Testing Payment Amount to recover from all benefitting regions","examples":["117762.01","46497","358460.11","178740"],"is_float":true},"RBF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Benefitting Factor for the RegionId","examples":["0","1"],"is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Testing Payment amount to recover from RegionId","examples":["-117762.01","0","-46497","-178740"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLING_NMAS_TST_RECVRY_RBF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":10},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":948,"decompressed_size_all_time":201870},"visibility":"Public","trigger":"Posting of a billing run"},"BILLING_NMAS_TST_RECVRY_TRK":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"NMAS_TST_RECVRY_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#190"],"comment":"BILLING_NMAS_TEST_RECVRY_TRK tracks the energy data used to allocate the test payment recovery over the recovery period. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","primary_keys":["BILLRUNNO","CONTRACTYEAR","RECOVERY_BILLRUNNO","RECOVERY_CONTRACTYEAR","RECOVERY_WEEKNO","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The current Billing RunNo for the week","examples":["10","16"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1 January","examples":["2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RECOVERY_BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Billing RunNo for energy data used in recovery calculation","examples":["11","15"],"is_integer":true,"num_int_bits":16},"RECOVERY_CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"AEMO Contract Year for energy data used in recovery calculation","examples":["2026"],"is_integer":true,"num_int_bits":16},"RECOVERY_WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Week no for energy data used in recovery calculation","examples":["5","27"],"is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1 January","examples":["28","31"],"warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_08/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23BILLING_NMAS_TST_RECVRY_TRK%23FILE01%23202608010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":8},"has_missing_months":true,"compressed_size_per_month":617,"decompressed_size_all_time":90850},"visibility":"Public","trigger":"Posting of a billing run"},"BILLING_RES_TRADER_PAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#102"],"comment":"Billing result table for reserve trader contract payments","unused":true,"primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","PARTICIPANTID","PAYMENT_TYPE","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Reserve trader contract identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier associated with the contract","is_categorical":true},"PAYMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"Payment type for the reserve trader contract payment amount"},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount to the participant","is_float":true}},"visibility":"Private","trigger":"When there is a reserve trader contract payment"},"BILLING_RES_TRADER_RECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#108"],"comment":"Billing result table for reserve trader contract recovery","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region id for the aggregated recovery amount","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount to be recovered from the participant","is_float":true}},"visibility":"Private","trigger":"When there is a reserve trader contract recovery"},"BILLING_SECDEPOSIT_APPLICATION":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"SECDEPOSIT_APPLICATION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#209"],"comment":"The security deposit application details","description":"BILLING_SECDEPOSIT_APPLICATION data is confidential, and is available\nonly to the relevant participant.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing run no. where the SDA is applied","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing contract year where (security deposit application) SDA is applied","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant ID lodging the SDA","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing week no. where the SDA is applied","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"APPLICATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SDA application amount","is_float":true}},"visibility":"Private","trigger":"After posting a billing run (final and revision)"},"BILLING_SECDEP_INTEREST_PAY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"SECDEP_INTEREST_PAY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#196"],"comment":"The interest amount for security deposit calculated by billing, based on whether it is a fixed/floating rate","description":"BILLING_SECDEP_INTEREST_PAY data is confidential, and is available only\nto the relevant participant.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","SECURITY_DEPOSIT_ID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing run no. the SDA application is processed and interest calculated","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing contract year the SDA application is processed and interest calculated","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant ID of the security deposit for whom the interest is paid","is_categorical":true},"SECURITY_DEPOSIT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The security deposit ID for which billing has calculated the Interest amount"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing week no. the SDA application is processed and interest calculated","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The interest account ID used by billing for calculating the interest.\nNULL if INTEREST_CALC_TYPE = FIXED"},"INTEREST_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The security deposit interest amount calculated by billing","is_float":true},"INTEREST_CALC_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"FIXED or DAILY"},"INTEREST_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The STATIC Interest Rate used by Billing for calculating the interest. This is NULL if INTEREST_CALC_TYPE <> FIXED","is_float":true}},"visibility":"Private","trigger":"After posting a billing run (final and revision)"},"BILLING_SECDEP_INTEREST_RATE":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"SECDEP_INTEREST_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#203"],"comment":"The DAILY interest rates used by billing when calculating the interest amount","primary_keys":["BILLRUNNO","CONTRACTYEAR","EFFECTIVEDATE","INTEREST_ACCT_ID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing run no. the SDA application is processed and interest calculated","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing contract year the SDA application is processed and interest calculated","is_integer":true,"unsigned_int":true,"num_int_bits":16},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The effective date of the new interest change","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The interest account ID used by security deposit interest calculation"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The billing week no. the SDA application is processed and interest calculated","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTEREST_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The interest rate to apply from the effective date","is_float":true}},"visibility":"Public","trigger":"After posting a billing run (final and revision)"},"BILLING_SUBST_DEMAND":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"SUBST_DEMAND","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#216"],"comment":"Demand Values Substituted in Billing Calculation","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","SETTLEMENTDATE","TNI","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the participant","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the connection point"},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Unique identifier for the region to which the TNI belongs to on this settlement date","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SUBSTITUTEDEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute metered quantity for non-energy recovery in MWh for the TNI and participant in the trading interval. A negative value indicates net consumption and a positive value indicates net generation","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLING_SUBST_RUN_VERSION":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"SUBST_RUN_VERSION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#222"],"comment":"Details of settlement runs used as input in the substitute demand calculation","primary_keys":["BILLRUNNO","CONTRACTYEAR","REFERENCESETTLEMENTDATE","REFERENCESETTLEMENTRUNNO","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REFERENCESETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REFERENCESETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The settlement run number matching the settlement date for a settlement run included in the reference period","is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLING_WDR":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"WDR","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#228"],"comment":"Billing WDR Transaction Weekly Summary","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number identifier","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract year of the Billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"DRSP or FRMP Participant Identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week number of the Billing run","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"WDR_CREDIT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR credit transaction amount","is_float":true},"WDR_DEBIT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR debit transaction amount","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLING_WDR_DETAIL":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"WDR_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.htm#234"],"comment":"Billing WDR transaction detail summary","primary_keys":["BILLRUNNO","CONTRACTYEAR","DRSP","FRMP","REGIONID","WDRRRPERIOD","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing run number identifier","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract year of the Billing run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DRSP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Demand Response Service Provider Identifier"},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Financial Responsible Market Participant Identifier"},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WDRRRPERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the period to which the WDRRR applies. For quarter-based periods, this will be equal to YYYY[Q]NN, for example, 2020Q3 for 2020 Quarter 3."},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week number of the Billing run","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"WDRRR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR reimbursement rate in $/MWh","is_float":true},"WDRSQ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR Settlement Quantity capped in MWh","is_float":true},"WDRTA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR transaction amount in $ for demand response","is_float":true}},"visibility":"Private","trigger":"Posting of a billing run"},"BILLINTERVENTIONRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#232"],"comment":"BILLINTERVENTIONRECOVERY shows billing market intervention recovery details for each participant.","description":"BILLINTERVENTIONRECOVERY data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINTERVENTIONRECOVERY updates when reserve trading occurs in a\nbilling run, such as during an Administered Price Cap event. View is\nempty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETINTERVENTION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount Retailer pays for Intervention with Market Recovery","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLINTERVENTIONREGIONRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#241"],"comment":"BILLINTERVENTIONREGIONRECOVERY shows billing region intervention recovery details for each participant by region.","description":"BILLINTERVENTIONREGIONRECOVERY data is confidential to the relevant\nparticipant.\n\nSource\n\nBILLINTERVENTIONREGIONRECOVERY updates when reserve trading occurs in a\nbilling run, such as during an Administered Price Cap event. View is\nempty until such an event occurs.","unused":true,"primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","REGIONID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONINTERVENTION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount retailer pays for intervention with Region Recovery","is_float":true}},"visibility":"Private","trigger":"When reserve trading occurs in a billing run"},"BILLRESERVETRADERPAYMENT":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"RESERVETRADERPAYMENT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#455"],"comment":"Details of the RERT Usage and Availability Payments made to the participant.","primary_keys":["BILLRUNNO","CONTRACTID","CONTRACTYEAR","PAYMENT_ID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing posted run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"RERT payment contract ID","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PAYMENT_ID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"RERT payment number","is_integer":true,"num_int_bits":16},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant identifier.","is_categorical":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RERT payment amount for the payment type","is_float":true},"PAYMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Description for the reserve trader contract payment amount."}},"visibility":"Private","trigger":"After posting a billing run (final and revision)"},"BILLRESERVETRADERRECOVERY":{"package":"BILLING_RUN","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING","REPORT_SUB_TYPE":"RESERVETRADERRECOVERY","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#461"],"comment":"Provides details of the RERT Recovery Amount for the Market Customers.","primary_keys":["BILLRUNNO","CONTRACTYEAR","PARTICIPANTID","PAYMENT_ID","PUBLICATION_ID","REGIONID","WEEKNO"],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing posted run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing contract year","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier.","is_categorical":true},"PAYMENT_ID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"RERT payment number","is_integer":true,"num_int_bits":16},"PUBLICATION_ID":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":true,"comment":"Unique Publication Identifier for RERT Payment"},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region from which the amount is recovered","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing week number","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ELIGIBILITY_END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Ending Period of RERT Recovery for Usage Payments","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ELIGIBILITY_START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Period of RERT Recovery for Usage Payments","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXCLUDED_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy Value (Scheduled Loads) that is excluded","is_float":true},"PARTICIPANT_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant ACE MWh Value used in the Recovery of the RERT Amount. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"PARTICIPANT_DEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand Value used for RERT Recovery. NULL for Billing Week post the IESS rule effective date.","is_float":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RERT payment amount","is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery Amount applicable for each Market Customer","is_float":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region ACE MWh Value used in the Recovery of the RERT Amount. NULL for Billing Week prior to the IESS rule effective date","is_float":true},"REGION_DEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Demand Value used for RERT Recovery. NULL for Billing Week post the IESS rule effective date.","is_float":true}},"visibility":"Private","trigger":"Populated by the posting of a billing run, being several times each week"},"BILLSMELTERRATE":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"BILLSMELTERRATE","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#250"],"comment":"BILLSMELTERRATE is standing data, setting out the rates used in smelter reduction calculations.","description":"BILLSMELTERRATE is public data, and is available to all participants.\n\nSource\n\nBILLSMELTERRATE updates infrequently, when inserting new annual rates.\n\nVolume\n\nTwo records inserted per year","unused":true,"primary_keys":["CONTRACTYEAR","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","examples":["1998","2021"],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar settlement date record becomes effective","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the record for the given effective date","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Who authorised","examples":["HAMISH","JWORMALD","LLITTLEMOR","SBUGGY","SCOTT","SRAJU","WING"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Authorised date","examples":["1998/03/29 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2002/01/10 17:47:07"],"parse_csv_as_string":true,"is_s_datetime":true},"RAR1":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Smelter rate 1","examples":["0","2"],"is_float":true},"RAR2":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Smelter rate 2","examples":["2.08","0","2.45"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_BILLSMELTERRATE_202407010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":7},"compressed_size_per_month":883,"decompressed_size_all_time":931490},"visibility":"Public","trigger":"Infrequently, when inserting new annual rates"},"BILLWHITEHOLE":{"package":"BILLING_RUN","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.htm#467"],"comment":"BILLWHITEHOLE shows white hole payments based on participant vs region demand.","description":"Confidential\n\nSource\n\nObsolete; was updated weekly with each billing run.","primary_keys":["BILLRUNNO","CONTRACTYEAR","INTERCONNECTORID","PARTICIPANTID","WEEKNO"],"indexes":[["LASTCHANGED"]],"columns":{"BILLRUNNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Unique run no within a given contract year and week no","is_integer":true,"unsigned_int":true,"num_int_bits":128},"CONTRACTYEAR":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":128},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector ID","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"WEEKNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Week no within the contract year. Week no 1 is the week containing 1st January","warnings":["There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The latest date and time that a file was updated or inserted","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NL":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of billing week (RRP * interconnector flow)","is_float":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of all customer purchases in MWh","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all region purchases in MWh","is_float":true},"WHITEHOLEPAYMENT":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment in $","is_float":true}},"visibility":"Private"},"CASH_SECURITY":{"package":"PRUDENTIALS","pdr_config":{"mappings":[{"REPORT_NAME":"PRUDENTIAL","REPORT_SUB_TYPE":"CASH_SECURITY","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec69.htm#7"],"comment":"Indicates the amount of cash security the participant has with AEMO","primary_keys":["CASH_SECURITY_ID"],"columns":{"CASH_SECURITY_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique ID for each cash security record"},"CASH_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Cash security amount(in dollars)","is_float":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Interest Account id used for daily interest calculation"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID(Provider of the Cash Security)","is_categorical":true},"RETURNED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Cash amount returned(In dollars)","is_float":true},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Active/Closed"},"TRANSACTION_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date when the CS was received by AEMO","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On change"},"CO2EII_AVAILABLE_GENERATORS":{"pdr_config":{"mappings":[{"REPORT_NAME":"CO2EII","REPORT_SUB_TYPE":"PUBLISHING","VERSION":1}]},"comment":"This table contains contain CO2 emissions intensity information,\nand simple fuel type per generator (`DUID`), as well as region information.\n","primary_keys":["STATIONNAME","DUID","GENSETID","REGIONID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM Dispatchable Unit Identifier","examples":["W/HOE#2","ER03","ER04","HUMEV"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Physical unit identifier","examples":["APPIN","AVLSF1","BANGOWF1","BANGOWF2"],"is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(4)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier that unit is in","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STATIONNAME":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":true,"examples":["Beryl Solar Farm","Bayswater Power Station","Hume (NSW) Hydro Power Station"]},"CO2E_DATA_SOURCE":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"Data source for `CO2E_ENERGY_SOURCE`.","examples":["ISP 2020","ISP2022","Estimate - Other","NGA 2024"]},"CO2E_EMISSIONS_FACTOR":{"sql_type":"NUMBER(1,8)","pl_type":"pl.Float64","mandatory":true,"is_float":true},"CO2E_ENERGY_SOURCE":{"sql_type":"VARCHAR(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The asset's fuel type","examples":["Bagasse","Battery Storage","Biomass and industrial materials","Black coal","Coal mine waste gas","Diesel oil","Ethane","Kerosene - non aviation","Hydro","Landfill biogas methane","Natural Gas (Pipeline)","Other Biofuels","Solar","Wind"],"warnings":["Since this table isn't documented, these values may change. New choices may be added. So be careful when using this data.\n"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Reports/CURRENT/CDEII/CO2EII_AVAILABLE_GENERATORS.CSV","warnings":[{"msg":"This table is missing from AEMO's documentation. The information here is my best guess from looking at the data.\n"},{"msg":"The data is saved in a different location to most data. It is only in [`CURRENT/CDEII`](https://www.nemweb.com.au/Reports/CURRENT/CDEII), not the monthly [MMSDM archive](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/). Unlike most other data, it is an unzipped CSV, not zipped. This folder contains both the latest version (`CO2EII_AVAILABLE_GENERATORS.CSV`) and some older versions. (`CO2EII_SUMMARY_RESULTS*.CSV` are a different but related table.)\n","category":"location"},{"msg":"This table has the same metadata columns (`REPORT_NAME`=`CO2EII` and `REPORT_SUB_TYPE`=`PUBLISHING`) as another table (`CO2EII_SUMMARY_RESULTS`), which is a similarly undocumented table.","category":"pdr"}]},"CO2EII_RESULTS_SUMMARY":{"pdr_config":{"mappings":[{"REPORT_NAME":"CO2EII","REPORT_SUB_TYPE":"PUBLISHING","VERSION":1}]},"comment":"This table contains contain CO2 emissions and emissions intensity information,\nper day per region.\n","primary_keys":["CONTRACTYEAR","WEEKNO","SETTLEMENTDATE","REGIONID"],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Billing year","examples":["2026"],"warnings":["This may not match the year of `SETTLMENDATE`. Billing years may be misaligned near the year start/end. e.g. `SETTLEMENTDATE` `2025/12/28 00:00:00` has `CONTRACTYEAR` of 2026\n"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(4)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region of emissions.","examples":null,"warnings":["Unlike most tables with a region column, this may include `NEM`, which is the sum of all other regions for that day."],"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date of emissions.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_date":true,"is_s_datetime":true},"WEEKNO":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Billing week","examples":["1","52","53"],"warnings":["There may be more than 52 billing weeks in a year, depending on which day of the week the year starts on.","There may be 53 weeks in a year, depending on how weeks align to the year start/end."],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"CO2E_INTENSITY_INDEX":{"sql_type":"NUMBER(1,4)","pl_type":"pl.Float64","mandatory":true,"comment":"Ratio of emissions to energy (tonnes CO2e per MWh)","is_float":true},"TOTAL_EMISSIONS":{"sql_type":"NUMBER(8,8)","pl_type":"pl.Float64","mandatory":true,"comment":"Ammount of emissions (CO2 equivillent, tonnes)","is_float":true},"TOTAL_SENT_OUT_ENERGY":{"sql_type":"NUMBER(8,8)","pl_type":"pl.Float64","mandatory":true,"comment":"Amount of energy (MWh) generated in this region.","warnings":["This this table is undocumented, it is unclear how transmission and distribution losses, and rooftop solar, are treated."],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Reports/CURRENT/CDEII/CO2EII_SUMMARY_RESULTS.CSV","warnings":[{"msg":"This table is missing from AEMO's documentation. The information here is my best guess from looking at the data.\n"},{"msg":"The data is saved in a different location to most data. It is only in [`CURRENT/CDEII`](https://www.nemweb.com.au/Reports/CURRENT/CDEII), not the monthly [MMSDM archive](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/). Unlike most other data, it is an unzipped CSV, not zipped. This folder contains both the latest version (`CO2EII_SUMMARY_RESULTS.CSV`) and seemingly identical file (`https://www.nemweb.com.au/Reports/CURRENT/CDEII/CO2EII_SUMMARY_RESULTS_2026.CSV`). (`CO2EII_AVAILABLE_GENERATORS*.CSV` are a different but related table.)\n","category":"location"},{"msg":"This table has the same metadata columns (`REPORT_NAME`=`CO2EII` and `REPORT_SUB_TYPE`=`PUBLISHING`) as another table (`CO2EII_SUMMARY_RESULTS`), which is a similarly undocumented table.","category":"pdr"}]},"CONNECTIONPOINT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#259"],"comment":"CONNECTIONPOINT shows all valid connection points and their type. Transmission loss factors are available for all connection points in TRANSMISSIONLOSSFACTOR.","description":"CONNECTIONPOINT data is confidential to each relevant participant\n\nSource\n\nCONNECTIONPOINT updates for new connection points as required.","unused":true,"primary_keys":["CONNECTIONPOINTID"],"indexes":[["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point Identifier","is_categorical":true},"ADDRESS1":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Connection point location"},"ADDRESS2":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Connection point location"},"ADDRESS3":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Connection point location"},"CITY":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"City"},"CONNECTIONPOINTNAME":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Connection point full description"},"CONNECTIONPOINTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point type. transmission, distribution, station, genunit, or interconnector"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"POSTCODE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Post Code"},"STATE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"State of Australia"},"ADDRESS4":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Not Used","unused":true}},"visibility":"Public","trigger":"When there are new connection points"},"CONNECTIONPOINTDETAILS":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#268"],"comment":"CONNECTIONPOINTDETAILS is obsolete, since it was never populated by Participants accessing AEMO's Oracle Interface.\nCONNECTIONPOINTDETAILS was designed to show relevant details for each connection point including the responsible party, loss factor and relevant MDAs.","description":"CONNECTIONPOINTDETAILS data is confidential to each participant included\nin details.\n\nSource\n\nCONNECTIONPOINTDETAILS updates periodically, such as for Transmission\nLoss Factor (TLF) changes","unused":true,"primary_keys":["CONNECTIONPOINTID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["METERDATAPROVIDER","NETWORKSERVICEPROVIDER","FINRESPORGAN"],["CONNECTIONPOINTID"],["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of record","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record for given effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGGREGATEDDATA":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Aggregate flag.","is_boolean":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DISTRIBUTIONLOSSFACTOR":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The distribution level loss factor for a distribution connection point","is_float":true},"FINRESPORGAN":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Financially responsible organisation"},"INUSE":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Status flag.","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LNSP":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Local Electricity Network Service Provider"},"LR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Local Retailer"},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Metering Data Agent for connection point."},"METERDATAPROVIDER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The MDA providing meter data for this connection point"},"NATIONALMETERINSTALLID":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"National Meter Id","is_float":true},"NETWORKSERVICEPROVIDER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The Network Service Provider"},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"ROLR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Retailer of last resort."},"RP":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Responsible party."},"TRANSMISSIONCPTID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Associated transmission connection point id for a distribution connection point"},"TRANSMISSIONLOSSFACTOR":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The transmission level loss factor for this connection point","is_float":true},"VALID_TODATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of validity.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Periodically with changes to connection point details"},"CONNECTIONPOINTOPERATINGSTA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#281"],"comment":"CONNECTIONPOINTOPERATINGSTA shows whether a connection point is active or not.","description":"CONNECTIONPOINTOPERATINGSTA data is confidential to each relevant\nparticipant.\n\nSource\n\nCONNECTIONPOINTOPERATINGSTA updates periodically with changes in\nconnection point status, such as for Transmission Loss Factor (TLF)\nchanges.","unused":true,"primary_keys":["CONNECTIONPOINTID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["CONNECTIONPOINTID"],["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of record","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(16)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"}},"visibility":"Public","trigger":"Periodically with changes to connection point status"},"CONSTRAINTRELAXATION_OCD":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCHOCD","REPORT_SUB_TYPE":"CONSTRAINTRELAXATION","VERSION":2},{"REPORT_NAME":"PRICELOAD","REPORT_SUB_TYPE":"CONSTRAINTRELAXATION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#1"],"comment":"CONSTRAINTRELAXATION_OCD contains details of interconnector constraints and unit ancillary service constraints relaxed in the over-constrained dispatch (OCD) re-run for this interval (if there was one).\nNote: INTERVENTION is not included in CONSTRAINTRELAXATION_OCD, since the relaxation of the same constraint is the same amount in both intervened and non-intervened cases.","description":"Source\n\nThe occurrences of Over-Constrained Dispatch (OCD) re-runs are ad hoc,\nwith significant dependencies on the configuration or events in the\nphysical power system.\n\nOver-constrained dispatch (OCD) re-run (if there was one).\n\nVolume\n\nRows per day: ~2\n\nMb per month: \\<1\n\nThe estimates on the number of rows are based on a 1% occurrence rate\nfor OCD runs.","primary_keys":["CONSTRAINTID","RUNNO","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier","examples":["F_T+LREG_0050","F_T_NIL_MINP_R6","Q_MOUSF1_0INV","T::T_HA_GT_PM_5"],"is_categorical":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date and time of the dispatch interval","examples":["2026/09/01 08:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version Number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 08:00:25"],"parse_csv_as_string":true,"is_s_datetime":true},"RHS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Relaxed RHS used in attempt to avoid constraint violation","examples":["-0.01","0.01","-537.87461","44.99"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23CONSTRAINTRELAXATION_OCD%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":623,"decompressed_size_all_time":154570},"visibility":"Public","trigger":"Ad hoc"},"CONTRACTAGC":{"package":"ANCILLARY_SERVICES","pdr_config":{"mappings":[{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTAGC","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.htm#1"],"comment":"CONTRACTAGC shows Automatic Generation Control (AGC) contract details for each dispatchable unit. There is a separate contract for each unit.","description":"CONTRACTAGC data is confidential to the relevant participant.\n\nSource\n\nCONTRACTAGC updates only where there is a contract variation.","primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID","CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BS":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Block Size","is_float":true},"CCPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap in $","is_float":true},"CRL":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Control Range Lower 5 Min MW","is_integer":true,"num_int_bits":16},"CRR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Control Range Raise 5 Min MW","is_integer":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"End date of contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RLPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Price in $","is_float":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When there is a contract variation"},"CONTRACTGOVERNOR":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#292"],"comment":"CONTRACTGOVERNOR became unused when Ancillary Services Review was implemented in 2001. For more details, see Change Notice 126.\nCONTRACTGOVERNOR shows Governor contract details used in the settlement and dispatch of this service. Note services are dispatched as 6 and 60 raise and lower Frequency Control Ancillary Services (FCAS). Lower and raise 6 and 60 second fields are used in dispatch of services. Deadband and Droop details are used in settlements.","description":"Confidential to participant\n\nSource\n\nNot in Use - discontinued 30/09/2001: was updated only where there was a\ncontract variation.","unused":true,"primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CCPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"DEADBANDDOWN":{"sql_type":"NUMBER(4,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Deadband","is_float":true},"DEADBANDUP":{"sql_type":"NUMBER(4,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Deadband","is_float":true},"DROOP6SECLOWERBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Lower 6 Second Breakpoint","is_float":true},"DROOP6SECLOWERMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Lower 6 Second Maximum","is_float":true},"DROOP6SECRAISEBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 6 Second Breakpoint","is_float":true},"DROOP6SECRAISECAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 6 Second Capacity","is_float":true},"DROOP6SECRAISEMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 6 Second Maximum","is_float":true},"DROOP60SECLOWERBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Lower 60 Second Breakpoint","is_float":true},"DROOP60SECLOWERMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Lower 60 Second Maximum","is_float":true},"DROOP60SECRAISEBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 60 Second Breakpoint","is_float":true},"DROOP60SECRAISECAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 60 Second Capacity","is_float":true},"DROOP60SECRAISEMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Droop Equation Raise 60 Second Maximum","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER6SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Lower 6 Second Breakpoint MW","is_float":true},"LOWER6SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Lower 6 Second Maximum MW","is_float":true},"LOWER60SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Lower 60 Second Breakpoint MW","is_float":true},"LOWER60SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Lower 60 Second Maximum MW","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"PRICE6SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Price for 6 Second Lower","is_float":true},"PRICE6SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Price for 6 Second Raise","is_float":true},"PRICE60SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Price for 60 Second Lower","is_float":true},"PRICE60SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Price for 60 Second Raise","is_float":true},"QUANT6SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Quantity for 6 Second Lower","is_float":true},"QUANT6SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Quantity for 6 Second Raise","is_float":true},"QUANT60SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Quantity for 60 Second Lower","is_float":true},"QUANT60SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Quantity for 60 Second Raise","is_float":true},"RAISE6SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 6 Second Breakpoint MW","is_float":true},"RAISE6SECCAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 6 Second Capacity MW","is_float":true},"RAISE6SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 6 Second Maximum MW","is_float":true},"RAISE60SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 60 Second Breakpoint MW","is_float":true},"RAISE60SECCAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 60 Second Capacity MW","is_float":true},"RAISE60SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 60 Second Maximum MW","is_float":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PRICE6SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE6SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT6SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT6SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}]},"CONTRACTLOADSHED":{"package":"ANCILLARY_SERVICES","pdr_config":{"mappings":[{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTLOADSHED","VERSION":1},{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTLOADSHED","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.htm#12"],"comment":"CONTRACTLOADSHED shows Governor contract details used in the settlement and dispatch of this service. Note: services are dispatched as 6 and 60 raise Frequency Control Ancillary Services (FCAS). Mandatory requirements and breakpoint details are not used for load shed. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"CONTRACTLOADSHED data is confidential to the relevant participant.\n\nSource\n\nCONTRACTLOADSHED updates only where there is a contract variation.","primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEFAULT_TESTINGPAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS default payment amount","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ILSCALINGFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SPD scaling factor for load shed vs dispatched, (1 = dispatched)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LSCR":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Control Range","is_float":true},"LSEPRICE":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The load shed enabling price for this contract","is_float":true},"MCPPRICE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Compensation price","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"PRICE6SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Price for 6 Second Raise","is_float":true},"QUANT6SECRAISECONTRACT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Quantity for 6 Second Raise","is_float":true},"RAISE6SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit Equation Raise 6 Second Maximum MW","is_float":true},"RAISE60SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum 60 second raise","is_float":true},"SERVICE_START_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The NMAS Testing Service Start Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TENDEREDPRICE":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price Tendered for Compensation per Trading interval - Not used since 13/12/1998","is_float":true},"LOWER6SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"LOWER6SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"LOWER60SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"LOWER60SECMAX":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE6SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE6SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE6SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECLOWERCONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECLOWERMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECRAISECONTRACT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PRICE60SECRAISEMANDATORY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT6SECLOWERCONTRACT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT6SECLOWERMANDATORY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT6SECRAISEMANDATORY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECLOWERCONTRACT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECLOWERMANDATORY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECRAISECONTRACT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"QUANT60SECRAISEMANDATORY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RAISE6SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RAISE6SECCAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RAISE60SECBREAKPOINT":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RAISE60SECCAPACITY":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"When there is a contract variation"},"CONTRACTREACTIVEPOWER":{"package":"ANCILLARY_SERVICES","pdr_config":{"mappings":[{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTREACTIVEPOWER","VERSION":3},{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTREACTIVEPOWER","VERSION":4}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.htm#23"],"comment":"CONTRACTREACTIVEPOWER shows Reactive Power contract details used in the settlement and dispatch of this service. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"CONTRACTREACTIVEPOWER data is confidential to the relevant participant.\n\nSource\n\nCONTRACTREACTIVEPOWER updates only where there is a contract variation.","primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["PARTICIPANTID"],["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABILITY_MWH_THRESHOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The MWh the unit must produce in a trading interval to be eligible for an excess-to-gen availability payment","is_float":true},"BS":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Block Size of Unit","is_float":true},"CCPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"DEFAULT_TESTINGPAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS default payment amount","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EU":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated Power consumption of unit when operating on SYNCCOMP","is_float":true},"ISREBATEAPPLICABLE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Used to check whether the contract is eligible for rebate. For new NSCAS contracts to apply new payment methodology this flag is 1.","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MMCA":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Capability for MVAr Absorption required by Code","is_float":true},"MMCG":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Capability for MVAr Generation required by Code","is_float":true},"MTA":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Absorption Capability (MVAr)","is_float":true},"MTG":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Generation Capability (MVAr)","is_float":true},"MVAR_THRESHOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The threshold value for MegaVar (MVAr) to check whether the service is fully available.","is_float":true},"MVARAPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability price per MVAr of RP absorption capability","is_float":true},"MVAREPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling price","is_float":true},"MVARGPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability price per MVAr of RP generation capability","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"PP":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated Price for supply","is_float":true},"REBATE_AMOUNT_PER_MVAR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The per MVAR rebate amount used to calculate the rebate payment.","is_float":true},"REBATE_CAP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The maximum capped amount for the rebate payment.","is_float":true},"SERVICE_START_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The NMAS Testing Service Start Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SYNCCOMPENSATION":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Sync Compensation Flag - Y for SYNCCOMP","is_boolean":true}},"visibility":"Private","trigger":"When there is a contract variation"},"CONTRACTRESERVEFLAG":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#303"],"comment":"CONTRACTRESERVEFLAG has never been or will be used. It was to show a period by period flag for regional or market recovery of reserve trading contract amounts.","description":"CONTRACTRESERVEFLAG data is confidential to the relevant participant.\n\nSource\n\nCONTRACTRESERVEFLAG updates when we want to enter a reserve contract.","unused":true,"primary_keys":["CONTRACTID","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Reserve Trader Contract Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Calendar settlement date period identifier, i.e. period 1 is 00:30","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Reserve Trader Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Reserve Recovery Flag"}},"visibility":"Private","trigger":"When entering a reserve contract"},"CONTRACTRESERVETHRESHOLD":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#312"],"comment":"CONTRACTRESERVETHRESHOLD shows reserve contract threshold details for enabling, usage and availability thresholds and rates for reserve trader contracts.","description":"CONTRACTRESERVETHRESHOLD data is confidential to the relevant\nparticipant.\n\nSource\n\nCONTRACTRESERVETHRESHOLD updates when reserve contracts are first\nentered or updated.","unused":true,"primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date contract was authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CRA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Rate $","is_float":true},"CRE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Rate $","is_float":true},"CRU":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Rate $","is_float":true},"CTA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Threshold MW/h","is_float":true},"CTE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Threshold MW/h","is_float":true},"CTU":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Threshold MW/h","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When reserve contracts are created or updated"},"CONTRACTRESERVETRADER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#321"],"comment":"CONTRACTRESERVETRADER shows reserve trader contract details. Version numbers do not apply as contracts exist for specified purposes.","description":"CONTRACTRESERVETRADER data is confidential to the relevant participant.\n\nSource\n\nCONTRACTRESERVETRADER updates when reserve trader activities occur.","unused":true,"primary_keys":["CONTRACTID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Reserve Trader Contract Identifier","is_categorical":true},"DEREGISTRATIONDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"De-registration date of contract; Not Used","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEREGISTRATIONPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"De-registration period of contract; Not Used","is_integer":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Terminate Date of contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Terminate period of contract based on calendar date.","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Starting period of contract","is_integer":true,"num_int_bits":16}},"visibility":"Private","trigger":"When reserve trader activities occur"},"CONTRACTRESTARTSERVICES":{"package":"ANCILLARY_SERVICES","pdr_config":{"mappings":[{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTRESTARTSERVICES","VERSION":1},{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTRESTARTSERVICES","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.htm#34"],"comment":"CONTRACTRESTARTSERVICES shows Restart Services contract details used in the settlement and dispatch of this service.","description":"CONTRACTRESTARTSERVICES data is confidential to the participant holding\nthe contract.\n\nSource\n\nCONTRACTRESTARTSERVICES updates only where there is a contract\nvariation.","primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["PARTICIPANTID"],["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEFAULT_TESTINGPAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS default payment amount","is_float":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RCPRICE":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Price","is_float":true},"RESTARTTYPE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Restart Type - 0 = BlackStart, 1 = Combination, 2 = Trip To House","is_integer":true,"num_int_bits":8},"SERVICE_START_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The NMAS Testing Service Start Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TRIPTOHOUSELEVEL":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Trip To House Level","is_integer":true,"num_int_bits":32}},"visibility":"Private","trigger":"When there is a restart contract"},"CONTRACTRESTARTUNITS":{"package":"ANCILLARY_SERVICES","pdr_config":{"mappings":[{"REPORT_NAME":"ANCILLIARY_SERVICES","REPORT_SUB_TYPE":"CONTRACTRESTARTUNITS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.htm#45"],"comment":"CONTRACTRESTARTUNITS shows Restart units provided under a system restart contract. A service can have multiple units.","description":"CONTRACTRESTARTUNITS data is confidential to each participant with a\nrestart contract.\n\nSource\n\nCONTRACTRESTARTUNITS updates only where there is a contract variation.","primary_keys":["CONTRACTID","DUID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of contract","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When there is a restart contract"},"CONTRACTUNITLOADING":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#330"],"comment":"CONTRACTUNITLOADING became unused when Ancillary Services Review was implemented in 2001. For more details, see Change Notice 126.\nCONTRACTUNITLOADING shows Unit Loading contract details used in the settlement and dispatch of this service.","description":"CONTRACTUNITLOADING is confidential to participants.\n\nSource\n\nCONTRACTUNITLOADING is not in Use - discontinued 30/09/2001; was updated\nonly where there was a contract variation.","unused":true,"primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACR":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Control Range","is_float":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BS":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Block Size of Unit","is_float":true},"CCPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EU":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated Power consumption of unit when enabled for RGUL","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"PP":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated Price for supply","is_float":true},"RPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Price","is_float":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SUPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Price","is_float":true}},"visibility":"Private"},"CONTRACTUNITUNLOADING":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#341"],"comment":"CONTRACTUNITUNLOADING shows Ancillary Service contract data for rapid generator unit unloading.","description":"CONTRACTUNITUNLOADING data is confidential to relevant participants.\n\nSource\n\nCONTRACTUNITUNLOADING updates only where there is a contract variation.","unused":true,"primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["PARTICIPANTID"],["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CCPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Price","is_float":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SUPRICE":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Price","is_float":true}},"visibility":"Private"},"DAYOFFER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#352"],"comment":"DAYOFFER sets out the participants’ daily components of participant bid containing details applying for the whole day (such as prices, daily energy constraint and fast start profiles).\nTo retrieve full bid details, read in conjunction with PEROFFER.","description":"DAYOFFER data is confidential to the submitting participant until made\npublic after 4am the next day.\n\nThe table DAYOFFER_D is quite distinct, with same field names (see\nDAYOFFER_D).","unused":true,"primary_keys":["DUID","OFFERDATE","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date of data","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:00am","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no. for given offer date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DAILYENERGYCONSTRAINT":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum energy available from Energy Constrained Plant.","is_float":true},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Daily or Rebid"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUMLOAD":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum MW load fast start plant in MW","is_integer":true,"num_int_bits":32},"MR_FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Mandatory Restriction Price Scaling Factor","is_float":true},"NORMALSTATUS":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Boolean","mandatory":false,"comment":"ON/OFF for loads","examples":["ON","OFF"],"parse_csv_as_string":true,"value_map":{"ON":1,"OFF":0},"is_boolean":true},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 7","is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","is_float":true},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities"},"T1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to synchronise in minutes","is_integer":true,"num_int_bits":32},"T2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to minimum load in minutes","is_integer":true,"num_int_bits":32},"T3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time at minimum load in minutes","is_integer":true,"num_int_bits":32},"T4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to shutdown in minutes","is_integer":true,"num_int_bits":32},"BANDQUANTISATIONID":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":8},"CONTINGENCYPRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPDOWN":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPUP":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"SELFCOMMITFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","unused":true}},"visibility":"Private & Public Next-Day","trigger":"Daily"},"DAYOFFER_D":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#363"],"comment":"DAYOFFER_D sets out the participants’ daily components of participant bid containing just the latest details (such as prices, daily energy constraint and fast start profiles).\nTo retrieve latest bid details, read in conjunction with PEROFFER_D.","description":"Not in Use - discontinued 16/11/2003\n\nDAYOFFER data was confidential to the submitting participant until made\npublic after 4am the next day.\n\nThe table DAYOFFER is quite distinct, with same field names (see\nDAYOFFER).","unused":true,"primary_keys":["DUID","OFFERDATE","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date of data","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:00am","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no. for given offer date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DAILYENERGYCONSTRAINT":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum energy available from Energy Constrained Plant.","is_float":true},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Daily or Rebid"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUMLOAD":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum MW load fast start plant in MW","is_integer":true,"num_int_bits":32},"MR_FACTOR":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Price Scaling Factor","is_integer":true,"num_int_bits":32},"NORMALSTATUS":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Boolean","mandatory":false,"comment":"ON/OFF for loads","examples":["ON","OFF"],"parse_csv_as_string":true,"value_map":{"ON":1,"OFF":0},"is_boolean":true},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 7","is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","is_float":true},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities"},"T1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to synchronise in minutes","is_integer":true,"num_int_bits":32},"T2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to minimum load in minutes","is_integer":true,"num_int_bits":32},"T3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time at minimum load in minutes","is_integer":true,"num_int_bits":32},"T4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to shutdown in minutes","is_integer":true,"num_int_bits":32},"BANDQUANTISATIONID":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":8},"CONTINGENCYPRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPDOWN":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPUP":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"SELFCOMMITFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","unused":true}},"visibility":"Public"},"DAYTRACK":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"DAYTRACK","VERSION":6},{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"DAYTRACK","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#1"],"comment":"DAYTRACK identifies the actual settlement run processed for each settlement day. Settlement run is in the column EXPOSTRUNNO. Generally, the number of the settlement run used in the latest statement is the maximum number.","description":"DAYTRACK is a public data, and is available to all participants.\n\nSource\n\nDAYTRACK is populated by the posting of a billing run.\n\nVolume\n\nDaily billing runs insert one row per day. A non-interim statement has\nseven records inserted per week. An indicative maximum is 35 records\ninserted per week.","primary_keys":["EXPOSTRUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"EXPOSTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Run No","examples":["1","11"],"is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/02/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"EXANTERUNSTATUS":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"This is to determine whether the Settlement Run is a valid run or not.","examples":["VALID"]},"EXPOSTRUNSTATUS":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Estimate for DAILY/INITIAL and Actual for PRELIM/FINAL and REVISE.","examples":["ACTUAL","ESTIMATE"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/24 08:39:22"],"parse_csv_as_string":true,"is_s_datetime":true},"METER_CASEID":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"The Metering Case Id used for the Settlement Run. For Estimate Daily Run this will be 0","examples":["0","11781","11852"],"is_integer":true,"num_int_bits":32},"METER_RUNTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Type of Settlement Run(ESTIMATE/PRELIM/FINAL/REVISE)","examples":["ESTIMATE","FINAL","PRELIM","RREV0","RREV1","RREV2"]},"SETTLEMENTINTERVALLENGTH":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Length of a settlement interval, in minutes (was 30 minutes, will be 5 minutes starting the commencement of 5MS rule change date).","examples":["5"],"is_integer":true,"num_int_bits":16},"EXANTERUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Not Used","unused":true,"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"MARKET\"])","mandatory":false,"comment":"Not Used","examples":null,"unused":true,"warnings":["Unlike most tables, this column does not reflect region IDs. It is always `MARKET`."],"enums":["MARKET"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DAYTRACK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":2352,"decompressed_size_all_time":2359080},"visibility":"Public","trigger":"After posting of a billing run"},"DEFAULTDAYOFFER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#374"],"comment":"DEFAULTDAYOFFER shows day-based details of participants’ default bids unit for the same day.","description":"Source\n\nObsolete; was updated only when participant changed their default bid.","unused":true,"primary_keys":["DUID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:30","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No for given offer date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DAILYENERGYCONSTRAINT":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum energy available from Energy Constrained Plant.","is_float":true},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Daily or Rebid"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUMLOAD":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum stable load","is_integer":true,"num_int_bits":32},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 7","is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","is_float":true},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities"},"T1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to synchronise in minutes","is_integer":true,"num_int_bits":32},"T2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to minimum load in minutes","is_integer":true,"num_int_bits":32},"T3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time at minimum load in minutes","is_integer":true,"num_int_bits":32},"T4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Time to shut down in minutes","is_integer":true,"num_int_bits":32},"BANDQUANTISATIONID":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":8},"CONTINGENCYPRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPDOWN":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"MAXRAMPUP":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"SELFCOMMITFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","unused":true}},"visibility":"Private"},"DEFAULTOFFERTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#383"],"comment":"DEFAULTOFFERTRK shows the file names of default offers submitted for each unit.","description":"Source\n\nObsolete; was updated only when participant changed their default bid.","unused":true,"primary_keys":["DUID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date default offer file is effective","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of file for this date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Load File identifier"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"DEFAULTPEROFFER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#392"],"comment":"DEFAULTPEROFFER shows half hourly period-based data in the default bid for each Dispatchable Unit, such as period availability, rate of change and band quantities.","description":"Source\n\nObsolete; was updated only when participant changes their default bid.","unused":true,"primary_keys":["DUID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market data. Trading Interval number","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:30","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the offer file.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BANDAVAIL1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 1","is_integer":true,"num_int_bits":32},"BANDAVAIL2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 2","is_integer":true,"num_int_bits":32},"BANDAVAIL3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 3","is_integer":true,"num_int_bits":32},"BANDAVAIL4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 4","is_integer":true,"num_int_bits":32},"BANDAVAIL5":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 5","is_integer":true,"num_int_bits":32},"BANDAVAIL6":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 6","is_integer":true,"num_int_bits":32},"BANDAVAIL7":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 7","is_integer":true,"num_int_bits":32},"BANDAVAIL8":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 8","is_integer":true,"num_int_bits":32},"BANDAVAIL9":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 9","is_integer":true,"num_int_bits":32},"BANDAVAIL10":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 10","is_integer":true,"num_int_bits":32},"FIXEDLOAD":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW. A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXAVAIL":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum planned availability MW","is_float":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The physical plant capability including any capability potentially available within 24 hours.","is_integer":true,"num_int_bits":64},"ROCDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Rate of change down MW/min","is_integer":true,"num_int_bits":32},"ROCUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Rate of change up MW/min","is_integer":true,"num_int_bits":32},"SELFDISPATCH":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private"},"DELTAMW":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#401"],"comment":"DELTAMW sets out the Frequency Control Ancillary Services (FCAS) requirement to be provided locally within each region and each half-hour period in a market day. Two fields specify Frequency Controlled Ancillary Services requirements to be provided locally for the new regulation ancillary services.","description":"Change Notice 324 (for the FCAS Constraint enhancements project) means\nthat Dispatch no longer utilises the static FCAS requirements defined in\nthe DELTAMW and RESERVE tables. These tables are replaced with\nconstraint data as a source of FCAS requirements.\n\nThe name of the table derives from the now obsolete delta MW for\nparticipant factors in Queensland.\n\nSource\n\nDELTAMW updates result from action by operational control staff,\ngenerally once a day.\n\nNot in Use - discontinued 16/11/2003","unused":true,"primary_keys":["PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Market trading interval from 1 to 48 starting at 04:30","is_integer":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:30","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of record for this date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER5MIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower 5 min local share requirement","is_integer":true,"num_int_bits":32},"LOWER6SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower 6 sec local share requirement","is_integer":true,"num_int_bits":32},"LOWER60SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower 60 sec local share requirement","is_integer":true,"num_int_bits":32},"LOWERREG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower Regulation local share requirement","is_integer":true,"num_int_bits":32},"RAISE5MIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise 5 minute local share requirement","is_integer":true,"num_int_bits":32},"RAISE6SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise 6 sec local share requirement","is_integer":true,"num_int_bits":32},"RAISE60SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise 60 sec local share requirement","is_integer":true,"num_int_bits":32},"RAISEREG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise Regulation local share requirement","is_integer":true,"num_int_bits":32},"DELTAMW":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Not Used","unused":true,"is_integer":true,"num_int_bits":32}},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"When there is an action by operational control staff"},"DEMANDOPERATIONALACTUAL":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"OPERATIONAL_DEMAND","REPORT_SUB_TYPE":"ACTUAL","VERSION":2},{"REPORT_NAME":"OPERATIONAL_DEMAND","REPORT_SUB_TYPE":"ACTUAL","VERSION":3}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#1"],"comment":"Shows Actual Operational Demand for a particular date time interval.","primary_keys":["INTERVAL_DATETIME","REGIONID"],"indexes":[["INTERVAL_DATETIME","REGIONID"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date time interval for operational demand value","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:30:02"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATIONAL_DEMAND":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Average 30-minute measured operational demand MW value (unadjusted)","examples":["774","8935"],"is_integer":true,"num_int_bits":64,"col_name_also_metadata":true},"OPERATIONAL_DEMAND_ADJUSTMENT":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Adjustment value containing the estimated amount of activated RERT and involuntary load shedding that occurred as a result of a NER 4.8.9 instruction for load shedding from AEMO.","examples":["0"],"is_integer":true,"num_int_bits":64},"WDR_ESTIMATE":{"sql_type":"NUMBER(10)","pl_type":"pl.Int64","mandatory":false,"comment":"Estimated average 30-minute MW amount of Wholesale Demand Response that occurred","examples":["0"],"is_integer":true,"num_int_bits":64}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DEMANDOPERATIONALACTUAL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":46524,"decompressed_size_all_time":12298910},"visibility":"Public","warnings":[{"msg":"The REPORT_NAME metadata column has the same column name as an actual columns OPERATIONAL_DEMAND. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"},{"msg":"The REPORT_NAME metadata column has the same column name as an actual columns OPERATIONAL_DEMAND. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"Ad hoc"},"DEMANDOPERATIONALFORECAST":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"OPERATIONAL_DEMAND","REPORT_SUB_TYPE":"FORECAST","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#9"],"comment":"Shows Forecast Operational Demand for a particular date time interval.","primary_keys":["INTERVAL_DATETIME","REGIONID"],"indexes":[["INTERVAL_DATETIME","REGIONID"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Forecast for a particular date time interval","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/31 23:57:09"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this forecast was produced","examples":["2026/08/31 23:57:09"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATIONAL_DEMAND_POE10":{"sql_type":"NUMBER(15,2)","pl_type":"pl.Float64","mandatory":false,"comment":"10% probability of exceedance operational demand forecast value","examples":["4885.11","762","5423.1","9120"],"is_float":true},"OPERATIONAL_DEMAND_POE50":{"sql_type":"NUMBER(15,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% probability of exceedance operational demand forecast value","examples":["730","8994"],"is_float":true},"OPERATIONAL_DEMAND_POE90":{"sql_type":"NUMBER(15,2)","pl_type":"pl.Float64","mandatory":false,"comment":"90% probability of exceedance operational demand forecast value","examples":["4744.89","698","5265.9","8869"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DEMANDOPERATIONALFORECAST%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":108495,"decompressed_size_all_time":30261590},"visibility":"Public","trigger":"Ad hoc"},"DISPATCHABLEUNIT":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DISPATCHABLEUNIT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#31"],"comment":"DISPATCHABLEUNIT sets out the unit name and type of each dispatchable unit in the market.","description":"DISPATCHABLEUNIT data is public data, and is available to all\nparticipants.\n\nSource\n\nDISPATCHABLEUNIT pdates as new units added or names changed.","primary_keys":["DUID"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["ADPBA1","ADPBA1G","ADPBA1L","ADPMH1","ADPPV1","ADPPV2","ADPPV3","AGLHAL","AGLNOW1","AGLSITA1","AGLSOM","ALDGASF1","AMCORGR","ANGAS1","ANGAS2","ANGAST1","APD01","APD02","APPIN","APS","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNACTW1","ASNAES1","ASNBRL1","ASNENC1","ASNSEL2","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSEL1","ASSENC1","ASSERDV1","ASSSN1","ASTFG1V1","ASTHYD1","ASVIEL2","AS_NSW1","AVLSF1","AWABAREF","BAKING1","BALB1","BALBG1","BALBL1","BALDHWF1","BANGOWF1","BANGOWF2","BANKSPT1","BANN1","BAPS","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BAYNL1","BBASEHOS","BBATRYL1","BBATTERY","BBATTERY1","BBDISEL1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BDONGHYD","BELLBAY1","BELLBAY2","BERWICK","BERYLSF1","BHASZINC","BHB1","BHBG1","BHBL1","BLNKTAS","BLNKVIC","BLOWER","BLOWERNG","BLUEGSF1","BLUFF1","BLULAKE1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVAR1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWBA1G","BOWWBA1L","BOWWDG1","BOWWPV1","BPLANDF1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDSF01","BRNDBES1","BROADMDW","BROKENH1","BROOKLYN","BROWNMT","BRYB1WF1","BRYB2WF2","BULBES1","BULBESG1","BULBESL1","BULGANA1","BUNGAMB1","BURRIN","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALLNL1","CALLNL2","CALLNL3","CALLNL4","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CAPBES1","CAPBES1G","CAPBES1L","CAPTL_WF","CATAGUN1","CATA_1","CATA_2","CATHROCK","CBWF1","CBWWBA1","CBWWBA1G","CBWWBA1L","CBWWBG1","CBWWDG1","CBWWDG2","CBWWPV1","CBWWPV2","CESF1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHBESSG1","CHBESSL1","CHILDSF1","CHPSTWF1","CHYTWF1","CLARESF1","CLAYTON","CLEMGPWF","CLERMSF1","CLOVER","CLOVER1","CLOVER2","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","CODRNGTON","COHUNSF1","COLEASF1","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","COLUMSF1","COLWF01","CONDONG1","COOPGWF1","COPTNHYD","CORIO1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DAANDINE","DALNTH01","DALNTH1","DALNTHL1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIAPURWF1","DLNKNSW","DLNKQLD","DPNTB1","DPNTBG1","DPNTBL1","DRACAN1","DRACAV1","DRAESN1","DRAESN3","DRBRLV01","DREXMN01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL","DRYCNL3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EASTCRK","EASTCRK2","EDENVSF1","EDLRGNRD","EILDON1","EILDON2","EILDON3","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERGT01","ERG_AS","ERNL1","FARLEIGH","FINLYSF1","FISHER","FLYCRKWF","FNWF1","FSWF1","GANGARR1","GANNB1","GANNBG1","GANNBL1","GANNSF1","GB01","GB02","GEORGTN1","GEORGTN2","GERMCRK","GESF1","GIRGSF","GLADNL1","GLBWNHYD","GLENMAG1","GLENNCRK","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GORDON1","GORDON2","GORDON3","GOVILLB1","GPWFEL1","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWL1","GPWFWST1","GPWFWST2","GRANGEAV","GRANWF1","GREENB1","GRIFSF1","GROSV1","GROSV2","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTH-1","GUTH-2","GUTHEGA","GUTHNL1","HALAMRD1","HALLWF1","HALLWF2","HAMISF1","HASTING1","HASTING2","HASTING3","HAUGHT11","HAUGHTSS","HAYMSF1","HBESS1","HBESSG1","HBESSL1","HD1WF1","HDWF1","HDWF2","HDWF3","HEPWIND1","HEZ","HEZ1","HIGHBRY1","HILLSTN1","HLMSEW01","HPR1","HPRG1","HPRL1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVGTS","HVWWBA1","HVWWBA1G","HVWWBA1L","HVWWPV1","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KARYNL1","KEEPIT","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINCUM1","KINGASF1","KKGTS","KPP_1","KRCCOGEN","KSP1","LADBROK1","LADBROK2","LANCSF1","LAVNORTH","LBB1","LBBG1","LBBL1","LD01","LD02","LD03","LD04","LDBESS1","LEMONTME","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LIDDNL1","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONGFORD","LONSDALE","LOYYB1","LOYYB2","LRSF1","LUCAS2S2","LUCASHGT","LVES1","LYA1","LYA2","LYA3","LYA4","LYGS1","LYGS2","LYGS3","LYGS4","LYGS5","LYGS6","LYNL1","L_W_CNL1","MACARTH1","MACKAYGT","MACKNADE","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARIAN","MAROOWF1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MCKAY2","MEADOWB2","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MIDLDPS1","MINTARO","MINTNL1","MLINKSA","MLINKVIC","MLLFGEF1","MLSP1","MLWF1","MM3","MM4","MMNL1","MOKOSF1","MOLNGSF1","MOORABS1","MOORAWF1","MOR1","MOR2","MOR3","MORANBAH","MOREESF1","MORNL1","MORNW","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPNL1","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRIDGE","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULGRAVE","MURAYNL1","MURAYNL2","MURAYNL3","MURR1-1","MURR1-10","MURR1-2","MURR1-3","MURR1-4","MURR1-5","MURR1-6","MURR1-7","MURR1-8","MURR1-9","MURR2-1","MURR2-2","MURR2-3","MURR2-4","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NASF1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NGTS","NINEWIL1","NPS","NPS1","NPS2","NPSNL1","NPSNL2","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","OAKY2","OAKYCREK","ORABESS1","OSB-AG","OSB01","OSB02","PALOONA","PAREPS1","PAREPW1","PARSF1","PEDLER1","PIBESS1","PIBESSG1","PIBESSL1","PINDARI","PIONEER","PLANECRK","PLAYB-AG","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PLEYSTOW","PMATTAEP","PO110NL1","POAT110","POAT220","POATINA1","POATINA2","POR01","POR03","PORTLAT1","PORTWF","PPCCGT","PTH01","PTH02","PTH03","PTSTAN1","PUMP1","PUMP2","QBYNB1","QBYNBG1","QBYNBL1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","QUERIVE1","RACOMIL1","RANGEB1","RCOURSE","REDBANK1","REECE1","REECE2","REMOUNT","REPULSE","RESS1","RESS1G","RESS1L","RIVNB2","RIVNBG2","RIVNBL2","ROCHEDAL","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUBICON","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SATGN1","SATGS1","SEBSF1","SHEP1","SHGEN","SHGEN2","SHOAL1","SHOALHAV","SHP01","SHPUMP","SITHE01","SKSF1","SLDCBLK1","SMCSF1","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUGNL1","SNWYGJP1","SNWYGJP2","SOMERSET","SRSF1","STAN-1","STAN-2","STAN-3","STAN-4","STANNL1","STANV1","STANV2","STAPYLTON1","STARHLWF","STGEORG1","STHBKTEC","STHJST","STOCKYD1","STPN1","STUBSF1","STUBSF2","STWF1","SUNCOAST","SUNRSF1","SUNSHINE","SUNTPSF1","SVALE1","SWANBBF1","SWANNL1","SWANNL2","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","SWAN_E","SYMEX1","TABMILL2","TAHMOOR1","TALWA1","TALWB1","TARALGA1","TARBESS1","TARNL1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TATIARA1","TATURA01","TB2B1","TB2BG1","TB2BL1","TB2SF1","TBLD","TBSF1","TEATREE1","TEMPB1","TERALBA","TERMSTOR","TGNSS1","THEDROP1","TIB1","TIBG1","TIBL1","TIMWEST","TITREE","TNPS1","TOMAGO1","TOMAGO2","TOMAGO3","TOORAWF","TORNL1","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TOWER","TREVALLN","TREV_1","TREV_2","TREV_3","TREV_4","TRGBESS1","TRIBNL1","TRIBUTE","TULLYSM1","TUMT3NL1","TUMT3NL2","TUMT3NL3","TUMUT1-1","TUMUT1-2","TUMUT1-3","TUMUT1-4","TUMUT2-1","TUMUT2-2","TUMUT2-3","TUMUT2-4","TUMUT3","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","TUNGATIN","TUNGA_3","TUNGA_4","TVCC201","TVPP104","TYPHOONW","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","UWS1","VALDORA1","VBB1","VBBG1","VBBL1","VENUS1","VICMILL1","VICSMLT","VICSMLT2","VP5","VP6","VPGS","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VPNL1","VSNEL2S1","VSNSN1V1","VSQHT1V1","VSSAE1V1","VSSEL1V1","VSSSE1V1","VSSSH1S1","VSVEL2S1","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WALGRVG1","WALGRVL1","WAMBOWF1","WANDB1","WANDBG1","WANDBL1","WANDSF1","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDBESSG1","WDBESSL1","WDGPH1","WDLNGN01","WELLSF1","WELNSF1","WEMENSF1","WESTCBT1","WESTILL1","WG01","WGULLY","WGWF1","WHILL1","WHIT1","WHITSF1","WILGAPK","WILGB01","WILLHOV1","WINGF1_1","WINGF2_1","WINTSF1","WIVENSH","WKIEWA1","WKIEWA2","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOLLERT1","WONWP","WOODLWN1","WOOLGSF1","WOOLNTH1","WOYWOY1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WW7","WW8","WWNL1","WYA252B1","WYANGALA","WYANGALB","WYASF1","WYB252B1","WYNDW","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YAWWF1","YENDWF1","YSWF1","YWNGAHYD","YWNL1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"DUNAME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Dispatchable Unit full description","examples":["ACTEWAGL VPP","ADAP UNDER FREQ L ","ADELAIDE DESAL BESS","ADELAIDE DESAL BG1","ADELAIDE DESAL BL1","ADELAIDE DESAL HYDRO","ADELAIDE DESAL PV1","ADELAIDE DESAL PV2","ADELAIDE DESAL PV3","AGG INTERRUP LOAD N1","AGG INTERRUP LOAD Q1","AGG INTERRUP LOAD S1","AGG INTERRUP LOAD V1","AGL LIDDELL BESS","AGL SITA LANDFILL 1","AGLHAL AGL HALLET, S","AGLNOW1 WEST NOWRA 1","AGLSOM AGL SOMERTON,","ALDOGA SOLAR FARM","AMCOR GAWLER UNT 1&2","ANGAS1 ANGASTON POWE","ANGAS2 ANGASTON POWE","ANGASTON PS","APD01 PORTLAND","APD02 PORTLAND","APPIN PP UNITS 1-54","APS ANGLESEA POWER S","ARARAT WIND FARM","AS ACLESGA V VL1","AS AES NSW 1","AS BOHLE BESS Q VL1","AS DIAMD01 V SL1","AS ENGIE N VL1","AS ENGIE V VL1","AS FIRMGRID TAS1 VL1","AS GENE N VL1","AS PAPOWERMG S 1","AS POWERSYNC V VL 1","AS RMGE S VL1","AS RMGE S VL2","AS RMGE S VL3","AS SER DR V1","AS SONNEN SA VL1","AS TEP ENLOC N VL2","AS TEP ENLOC V VL2","ASRMGE04","AVONLIE SOLAR FARM","Awaba ","BAKING BOARD SOLAR","BALDHWF1","BALLARAT BASE HOSP","BALLARAT BATT (GEN) ","BALLARAT BATT (LOAD)","BALLARAT BESS","BANGO WIND FARM 973","BANGO WIND FARM 999","BANKSTOWN SPORTS CLB","BANNERTON SOLAR PARK","BARCALDINE SOLAR ","BARCALDN BARCALDINE","BARKER INLET PS","BARRON-1 BARRON GORG","BARRON-2 BARRON GORG","BASTYAN BASTYAN","BAYNL1 BAYSW","BBATTERY LOAD","BDL01 BAIRNSDALE","BDL02 BAIRNSDALE","BELL BAY DIESEL","BELL BAY THREE 3 ","BELLBAY THREE2","BELLBAY1 BELL BAY","BELLBAY2 BELL BAY","BERRYBANK 2 WF","BERRYBANK1 WIND FARM","BERWICK POWER PLANT ","BERYL SOLAR FARM","BHASZINC BHAS ZINC P","BHBESS","BHBESS GEN","BHBESS LOAD","BLNKTAS BASSLINK INT","BLNKVIC BASSLINK INT","BLOWER BLOWERING","BLOWERNG BLOWERNG","BLUE GRASS SF","BLUE LAKE MILLING 1","BLYTH BESS","BOCO ROCK WIND FARM ","BODANGORA WIND FARM","BOLIVAR PLANT","BOLIVAR WWTP BESS","BOLIVAR WWTP BG1","BOLIVAR WWTP BL1","BOLIVAR WWTP DG1","BOLIVAR WWTP PV1","BOLIVARPOWERSTATION1","BOMENSF1","BORAL AGG LOAD NSW1","BOULDERCOMBE BATTERY","BOULDERCOMBE BESS","BRAEMAR 2 UNIT 5","BRAEMAR 2 UNIT 6","BRAEMAR 2 UNIT 7","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRENDALEBESS1","BROADMEADOW UNT 1-5","BROADSOUND SF","BROADWATER UNIT 1","BROKENH SOLAR","BROOKLYN LFG U1-3","BROWN PLAINS LFG PS","BROWNMT BROWN MT POW","BULGANA BESS","BULGANA BESS 1","BULGANABESSLOAD","BULGANAGREENPOWERHUB","BUNDABERG SF","BUNGALA ONE SF","BUNGALA TWO SF","BUNGAMA BESS1","BURRENDONG TURBINE","BURRIN BURRINJUCK PO","BUTLERSG BUTLERS GOR","BW01 BAYSWATER","BW02 BAYSWATER","BW03 BAYSWATER","BW04 BAYSWATER","Banimboola","Bell Bay Three 1","C'VILLE SOLAR PV 1","CALLNL1 CALLIDE","CALLNL2 CALLIDE C NE","CALLNL3 CALLIDE C NE","CALL_A_1 CALLIDE","CALL_A_2 CALLIDE","CALL_A_3 CALLIDE","CALL_A_4 CALLIDE","CALL_B_1 CALLIDE","CALL_B_2 CALLIDE","CANUNDA","CAPBES1G","CAPITAL BATTERY","CAPITAL WIND FARM","CAPTIAL EAST SF","CARWARP SF 1","CATAGUNYA PS","CATA_1 LIAP, CATA, W","CATA_2 LIAP, CATA, W","CATHROCK CATHEDRAL R","CATTLE HILL WF 1","CBESSL","CETHANA CETHANA","CHALLICUM HILLS WF","CHBESS","CHBESS GENERATOR","CHBESS LOAD","CHEPSTOWE_WF","CHERRY TREE WF","CHILDERS SF 1","CHRISTIESB WWTP BAG1","CHRISTIESB WWTP BAL1","CHRISTIESB WWTP BESS","CHRISTIESB WWTP BG1","CHRISTIESB WWTP DG1","CHRISTIESB WWTP DG2","CHRISTIESB WWTP PV1","CHRISTIESB WWTP PV2","CLARE SOLAR FARM","CLARKE CREEK WF1","CLARKE CREEK WF2","CLAYTON UNT 1-11","CLEMENTS GAP BESS1","CLEMENTS GAP WF","CLERMONT SOLAR FARM","CLOVER1 CLOVER POWER","CLOVER2 CLOVER POWER","CLUNY CLUNY","CODRINGTON WF 1-14","COHUNA SF PV ARRAY","COLEAMBALLY SF","COLLECTOR WIND FARM","COLNSNL1 COLNSV","COLNSV_1 COLINSVILLE","COLNSV_2 COLINSVILLE","COLNSV_3 COLINSVILLE","COLNSV_4 COLINSVILLE","COLNSV_5 COLINSVILLE","COLONGRA PS UNIT 1","COLONGRA PS UNIT 2","COLONGRA PS UNIT 3","COLONGRA PS UNIT 4","COLUMBOOLA SF","CONDAMINE PS A ","CONDONG UNIT 1","COONOOER BRIDGE WF","COOPERS GAP WF","COPETON HYDRO UNIT 1","CORIO LFG PS","COROWA SOLAR FARM","CPP_3 CALLIDE POWER ","CPP_4 CALLIDE POWER ","CROOKWELL 2 WF","CROOKWELL 3 WF","CROWLANDS WIND FARM","CRUDINE RIDGE WF","CULLERIN RGE WF 1-15","CUSF1","Clover Power Station","DAANDINE","DALBY HYBRID","DALRYMPLE NORTH BESS","DALRYMPLE NORTH GEN","DALRYMPLE NORTH LOAD","DARLING DOWNS PS 0-3","DARLING DOWNS SF","DARLINGTON PNT ESS1","DARLINGTON POINT BDU","DARLINGTON POINT SF","DARTM1 DARTMOUTH POW","DAYDREAM SOLAR FARM","DEVILS_G DEVILS GATE","DG_NSW1 NSW1 Dummy G","DG_QLD1 QLD1 Dummy G","DG_SA1 SA1 Dummy Gen","DG_TAS1 TAS1 Dummy G","DG_VIC1 VIC1 Dummy G","DIAPUR WIND FARM","DISCO-NRG S SL1","DLNKNSW DLINK INTERC","DLNKQLD DLINK INTERC","DPNTBL1","DR ACACIA N SL1","DR ACACIA V 1","DR AES N VL1","DR BORAL V SL1","DR ENELX N1","DR ENELX N16","DR ENELX N3","DR ENELX N31","DR ENELX N32","DR ENELX N34","DR ENELX N36","DR ENELX N37","DR ENELX N40","DR ENELX N42","DR ENELX N44","DR ENELX N49","DR ENELX N54","DR ENELX N55","DR ENELX N83","DR ENELX Q50","DR ENELX Q54","DR ENELX S2","DR ENELX V1","DR ENELX V12","DR ENELX V17","DR ENELX V2","DR ENELX V24","DR ENELX V240","DR ENELX V88","DR ENERGYX VL N1","DR FIRM INFRA T 1","DR FIRM INFRA T 2","DR GBND N1","DR GBND S1","DR GBND V 2","DR GBND V 3","DR HYDROTASVPP N 1","DR OZVPPQ S 1","DR OZVPPS S 1","DR OZVPPS V 1","DR POWERSYNC Q 1","DR POWERSYNC V 1","DR VIOTAS N SL1","DR VIOTAS Q SL1","DR VIOTAS S SL1","DR VIOTAS T SL1","DR VIOTAS V SL1","DR VIOTASWDR S 1","DRAESN3","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRYCGT1 DRY CREEK GA","DRYCGT2 DRY CREEK GA","DRYCGT3 DRY CREEK GA","DRYCNL DRY CREEK GAS","DRYCNL3 DRY CREEK GA","DULAWF1","DUNDONNELL WF 1","DUNDONNELL WF 2","DUNDONNELL WF 3","EASTERN CK 2 GAS FAC","EASTERN CRK LFG U1-4","EDENVALE SOLAR PARK","EDLRGNRD ROGHAN ROAD","EILDON HYDRO","EILDON1 EILDON POWER","EILDON2 EILDON POWER","ELAINE WIND FARM 1","EMERALD SOLAR PARK 1","ENERGY LOCALS SA VPP","ER01 ERARING POWER S","ER02 ERARING POWER S","ER03 ERARING POWER S","ER04 ERARING POWER S","ERARING BESS 1","ERARING GAS TURBINE","ERG_AS ERGON FREQUEN","ERNL1 ERARING","FARLEIGH FARLEIGH MI","FERGUSON NORTH","FERGUSON SOUTH","FINLEY SOLAR FARM","FISHER FISHER","FLYERS CREEK WF","GANGARRI SOLAR FARM","GANNAWARRA BATT GEN","GANNAWARRA BATT LOAD","GANNAWARRA BESS","GANNAWARRA SOLAR","GB01 BROKEN HILL GAS","GB02 BROKEN HILL GAS","GEORGE TOWN DIESEL","GEORGE TOWN PS","GIRGARRE SOLAR FARM","GLADNL1 G/STONE","GLENBAWN HYDRO UNT 1","GLENELLEN SF","GLENMAGGIE HYDRO U1","GLENNIES CREEK 1-12","GLENROWAN SOLAR FARM","GLENROWAN WEST SF1","GOESF1","GOONUMBLA SF","GORDON GORDON","GORDON1 GORDON","GORDON2 GORDON","GORDON3 GORDON","GOVILLB1 GORDON","GOYDER SOUTH WF 1A","GOYDER SOUTH WF 1B","GPWF EAST 1","GPWF EAST 2","GPWF EAST 3","GPWF EAST LOAD","GPWF WEST 1","GPWF WEST 2","GPWF WEST LOAD","GRANVILLE HARBOUR WF","GREENBANK BESS","GRIFFITH SOLAR FARM ","GROSVENOR 2 UNIT 1-5","GROSVENOR PS","GSTONE1 GLADSTONE PO","GSTONE2 GLADSTONE PO","GSTONE3 GLADSTONE PO","GSTONE4 GLADSTONE PO","GSTONE5 GLADSTONE PO","GSTONE6 GLADSTONE PO","GULLEN RANGE SOLAR ","GULLEN RANGE WF","GULLEN RANGE WF2","GUNNEDAH SF","GUNNING WIND FARM","GUNSYND SOLAR FARM","GUTH-1 GUTHEGA","GUTH-2 GUTHEGA","GUTHEGA GUTHEGA","GUTHNL1 GUTHEGA","German Creek","Grange Avenue Unit 1","HALLAM ROAD","HALLET WND FAM 1","HALLETT 2 WIND FARM","HAMILTON SOLAR FARM","HAPPEYVALLEY WTP BDU","HAPPYVALLEY WTP BG1","HAPPYVALLEY WTP BL1","HAPPYVALLEY WTP PV1","HASTING1","HASTING2","HASTING3","HAUGHTON SC","HAUGHTON SOLAR FARM","HAWKESDALE WF","HAYMAN SOLAR FARM","HAZELWOOD BESS","HBESS GENERATION 1","HBESSL1","HEPWIND COM WF UN1&2","HIGHBURY LFG UNIT 1","HILLSTON SUN FARM","HORNDALE WIND FARM 3","HORNSDALE BESS","HORNSDALE WF2","HORNSDALE WIND FARM","HRP GEN","HRP LOAD","HUGHENDEN SOLAR FARM","HUMENSW HUME HYDRO P","HUMEV HUME POWER STA","HUNTER 1","HUNTER 2","HUNTER ECONOMIC ZONE","HVGTS HUNTER VALLEY ","HWPNL1 HAZEL","HWPS1 HAZELWOOD","HWPS2 HAZELWOOD","HWPS3 HAZELWOOD","HWPS4 HAZELWOOD","HWPS5 HAZELWOOD","HWPS6 HAZELWOOD","HWPS7 HAZELWOOD","HWPS8 HAZELWOOD","Invicta Sugar Mill","Isis Central ","JACKSGUL JACKS GULLY","JBUTTERS JOHN BUTTER","JEMALONG SOLAR PROJ","JLA01 JEERALANG A PO","JLA02 JEERALANG A PO","JLA03 JEERALANG A PO","JLA04 JEERALANG A PO","JLB01 JEERALANG B PO","JLB02 JEERALANG B PO","JLB03 JEERALANG B PO","JOUNAMA SMALL HYD 1","JUNEE SF","Jindabyne Unit 1","KABAN WIND FARM 1","KARADOC SOLAR FARM","KAREEYA1 KAREEYA POW","KAREEYA2 KAREEYA POW","KAREEYA3 KAREEYA POW","KAREEYA4 KAREEYA POW","KAREEYA5 KAREEYA POW","KARYNL1 KAREEYA","KEEPIT KEEPIT POWER ","KEP BATTERY GEN","KEP BATTERY LOAD","KEP SOLAR","KEP WIND","KERANG SOLAR PLANT","KESSB1","KIAMAL SOLAR FARM","KIATA WIND FARM DUID","KIDSTON PH GEN1","KIDSTON PH GEN2","KIDSTON PH LOAD1","KIDSTON PH LOAD2","KIDSTON SOLAR ONE ","KINCUMBER LANDFILL","KINGAROY SF 1","KKGTS KOOLKHAN GAS T","KRC Kogeneration","Kogan Creek","LADBROK1 Ladbroke Gr","LADBROK2 Ladbroke Gr","LAKE BONNEY BESS","LAKE BONNEY BSSG1","LAKE BONNEY BSSL1","LAKE BONNEY STAGE 2","LAKEBONNY3 WF 1","LANCASTERSF1","LATROBE VALLEY ES1","LAVNORTH LAVERTON_NO","LD01 LIDDELL","LD02 LIDDELL","LD03 LIDDELL","LD04 LIDDELL","LEMONTME LEMTME & WI","LEM_WIL LEMTME & WIL","LGI MUGGA LANE","LIDDNL1 LIDDELL","LILYVALE SOLAR FARM","LIMONDALE BATTERY","LIMONDALE SF 1","LIMONDALE SF 2","LINCOLN GAP BESSBDU","LINCOLN GAP WF 1","LINCOLN GAP WF 2","LI_WY_CA LIAP, CATA,","LKBONNY1 LAKE BONNEY","LK_ECHO LAKE ECHO","LNGS1 LAVERTON_NO","LNGS2 LAVERTON_NO","LONGFORD LONGFORD PL","LONGREACH SOLAR FARM","LONSDALE CUMMINS LON","LOY YANG B UNIT 1","LOY YANG B UNIT 2","LUCAS HEIGHT 12-15","LUCAS HEIGHT U 1-11","LYA1 LOY YANG A POWE","LYA2 LOY YANG A POWE","LYA3 LOY YANG A POWE","LYA4 LOY YANG A POWE","LYGS1 VALLEY POWER","LYGS2 VALLEY POWER","LYGS3 VALLEY POWER","LYGS4 VALLEY POWER","LYGS5 VALLEY POWER","LYGS6 VALLEY POWER","LYNL1 LOYYANGA","L_W_CNL1 LIAP, CATA,","MACARTHUR WIND FARM","MACINTYRE WIND FARM","MACKAYGT MACKAY GAS ","MACKNADE MACKNADE SU","MACKNTSH MACKINTOSH","MANILDRA SOLAR FARM","MANNUM SOLAR FARM 2","MANNUM-ADELAIDEPS2","MANNUM-ADELAIDEPS3","MANNUMB1","MARIAN MARIAN MILL","MAROONA WIND FARM","MARYROSF1-12","MBO PS2 PV1","MCKAY POWER STATION","MCKAY2 MCKAY POWER S","MEADOWBANK DIESEL ","MEADOWBK MEADOW BANK","METZ SOLAR FARM","MIDDLEMOUNT SF","MIDLNDS PWR MINI HY ","MINTARO MINTARO GAS ","MINTNL1 MINTARO GAS ","MLINKSA MURLINK INTC","MLINKVIC MURLINK INT","MM3 MUNMORAH POWER S","MM4 MUNMORAH POWER S","MMNL1 MM","MOKOANSOLARFARM1","MOLONG SOLAR FARM","MOORABOOL NS BESS","MOORABOOL WF","MOR1 ENERGY BRIX COM","MOR2 ENERGY BRIX COM","MOR3 ENERGY BRIX COM","MORANBAH NTH PS","MOREE SOLAR FARM","MORGAN-WHYALLAPS1","MORGAN-WHYALLAPS2","MORGAN-WHYALLAPS3","MORGAN-WHYALLAPS4","MORNL1 ENERGYB","MORNW MORNINGTON WAS","MORTLAKE PS UNIT 1","MORTLAKE PS UNIT 2","MORTLAKE SOUTH WF","MORTONSL WF","MOURA SOLAR FARM","MP1 MT PIPER POWER S","MP2 MT PIPER POWER S","MPNL1 MP","MPP_1 MILLMERRAN PS","MPP_2 MILLMERRAN PS","MREHA1","MREHA2","MREHA3","MRIDGE SWANBANK","MSTUART1 MT STUART","MSTUART2 MT STUART","MT EMERALD WF","MT GELLIBRAND WF","MT MERCER WIND FARM","MT STUART UNIT 3","MTMILLAR MOUNT MILLA","MUGGA LANE SOLAR PAR","MULGRAVE MULGRAVE CE","MUNNA CREEK SF","MURAYNL1 MURRAY","MURAYNL2 MURRAY","MURAYNL3 MURRAY","MURR1-1 MURRAY1","MURR1-10 MURRAY1","MURR1-2 MURRAY1","MURR1-3 MURRAY1","MURR1-4 MURRAY1","MURR1-5 MURRAY1","MURR1-6 MURRAY1","MURR1-7 MURRAY1","MURR1-8 MURRAY1","MURR1-9 MURRAY1","MURR2-1 MURRAY2","MURR2-2 MURRAY2","MURR2-3 MURRAY2","MURR2-4 MURRAY2","MURRA WARRA WF 1","MURRAY MURRAY","MUSSELROE WF U 1-56","MUWAWF2","Moranbah Generation","NARROMINE SOLAR FARM","NEVERTIRE SOLAR FARM","NEW ENGLAND BESS1","NEW ENGLAND BESS2","NEW ENGLAND GS1","NEW ENGLAND GS2","NGTS NORTHERN GAS TU","NINE WILLOUGHBY 1-3","NORTH BROWN HILL WF ","NPS","NPS1 NORTHERN POWER ","NPS2 NORTHERN POWER ","NPSNL1 NORTHERN POWE","NPSNL2 NORTHERN POWE","NSCAS - TRANSGRID","NUMURKAH SOLAR FARM","NYNGAN SOLAR","OAKEY 1 SOLAR FARM","OAKEY 2 SOLAR FARM","OAKEY1 OAKEY POWER","OAKEY2 OAKEY POWER","OAKLANDS HILL WF","OAKY CREEK 2 ","ORABESS1","OSB-AG OSBORNE POWER","OSB01 OSBORNE POWER ","OSB02 OSBORNE POWER ","Oaky Creek PS","PALOONA PALOONA","PAREP SOLAR 1","PAREP WIND 1","PARKES SOLAR FARM","PB COMMUNITY SGA","PEDLER CRK UNT 1 - 3","PG-SEW MINI HYDRO","PIBESS","PIBESS GEN1","PIBESS LOAD1","PINDARI PINDARI HYDR","PLANECRK PLANE CREEK","PLAYB-AG PLAYFORD PO","PLAYFB1 PLAYFORD POW","PLAYFB2 PLAYFORD POW","PLAYFB3 PLAYFORD POW","PLAYFB4 PLAYFORD POW","PLEYSTOW PLEYSTOWE M","PMATTAEP PMATTAEP EA","PO110NL1 POATINA 110","POAT110 POATINA 110K","POAT220 POATINA 220K","POATINA1 POATINA 110","POATINA2 POATINA 110","POR01 PORT LINCOLN P","PORT LATTA DIESEL","PORT LINCOLN UNIT 3","PORT STANVAC 1","PORT STANVAC 2","PORTLAND WF","PPCCGT PELICAN POINT","PTH01 POINT HENRY SM","PTH02 POINT HENRY SM","PTH03 POINT HENRY SM","PUMP1 WIVENHOE POWER","PUMP2 WIVENHOE POWER","Pioneer Sugar Mill","QBYN BESS","QBYN BESS GEN","QBYN BESS LOAD","QPS1 QUARANTINE PS","QPS2 QUARANTINE PS","QPS3 QUARANTINE PS","QPS4 QUARANTINE PS","QUARANTINE PS UNIT 5","QUE RIVER DIESEL","QUORN PARK SH BESS","QUORN PARK SH PV","RACECOURSE MILL 1-3","RANGEBG","RCOURSE RACECOURSE M","REDBANK1 REDBANK POW","REECE1 REECE","REECE2 REECE","REMOUNT","REPULSE REPULSE","RESERVETRADERNSWUNT2","RESERVETRADERNSWUNT3","RESERVETRADERNSWUNT4","RESERVETRADERNSWUNT5","RESERVETRADERNSWUNT6","RESS1BG","RESS1BL","RIVERINA 1 BESS","RIVERINA 2 BESS","RIVERINA ESS 2","RIVERINA ESS L2","ROCHEDAL ROCHEDALE R","ROMA_7 Roma Power St","ROMA_8 Roma Power St","ROSSRIVER SOLAR FARM","ROYALLA SOLAR FARM 1","RPCG ROCKY PT COGEN","RT_NSW1 RESERVE TRAD","RT_QLD1 RESERVE TRAD","RT_SA1 RESERVE TRADE","RT_TAS1 RESERVE TRAD","RT_VIC1 RESERVE TRAD","RUBICON RUBICON MT S","RUGBYR1","RYAN CORNER WF","RYE PARK WIND FARM 1","ReserveTrader5Vic","ReserveTrader8Vic","ReserveTrader9Vic","ReserveTraderSAunit2","ReserveTraderSAunit3","ReserveTraderSAunit4","ReserveTraderSAunit5","ReserveTraderSAunit6","ReserveTraderUnit2 ","ReserveTraderVic10","ReserveTraderVic12","ReserveTraderVic3 ","ReserveTraderVic4 ","ReserveTraderVic6 ","ReserveTraderVic7 ","ReserveTraderVict11","Rowallan PS","SALT CREEK WIND FARM","SAPPHIRE WIND FARM 1","SCSF","SEBASTOPOL SF","SHEPPARTON 1","SHGEN SHOALHAVEN POW","SHGEN2 SHOALHAVEN PO","SHOAL COGEN1","SHOALHAVEN PS UNIT 1","SHOALHAVEN PUMP","SHPUMP SHOALHAVEN PO","SILVERTON WIND FARM","SITHE01 SMITHFIELD E","SMITHFIELD BESS","SNAPPER POINT POWER","SNOWTOWN WF S2NTH","SNOWTOWN WIND FARM","SNOWTWN STH WF U1-42","SNOWY1 SNOWY","SNOWY2 SNOWY","SNOWY3 SNOWY","SNOWY4 SNOWY","SNOWY5 SNOWY","SNOWY6 SNOWY","SNOWYGJP SNOWY","SNOWYP SNOWY","SNUG1 SNUGGERY POWER","SNUG2 SNUGGERY POWER","SNUG3 SNUGGERY POWER","SNUG4 SNUGGERY POWER","SNUGNL1 SNUGGERY POW","SNWYGJP1 SNOWY","SNWYGJP2 SNOWY","SOMERSET SOMERSET DA","SOUTH KESWICK SOLAR ","SPRINGVALE LFG ","ST GEORGE PLANT 1","ST LEONARDS BLOCK 1","STAN-1 STANWELL POWE","STAN-2 STANWELL POWE","STAN-3 STANWELL POWE","STAN-4 STANWELL POWE","STANNL1 STANWELL","STAPYLTON RENEWABLE","STARFISH HILL WF","STATION LOAD UNIT 4","STH BNK TECH UNIT 1","STHJST SOUTH JOHNSTO","STOCKYARD HILL","STPN1 STAPYLTON","STUBBO GS1","STUBBO GS2","SUN METALS SOLARFARM","SUNCOAST SUNCOAST GO","SUNRAYSIA SF","SUNSHINE SUNSHINE EN","SUNTOP SOLAR FARM","SUPERNODE BESS 1","SUPERNODE BESS 2","SUSANRIVERSOLARFARM","SWANBANK BESS1","SWANNL1 SWANBANK","SWANNL2 SWANBANK","SWAN_A_1 SWANBANK","SWAN_A_2 SWANBANK","SWAN_A_3 SWANBANK","SWAN_A_4 SWANBANK","SWAN_A_5 SWANBANK","SWAN_A_6 SWANBANK","SWAN_B_1 SWANBANK","SWAN_B_2 SWANBANK","SWAN_B_3 SWANBANK","SWAN_B_4 SWANBANK","SWAN_C SWANBANK","SWAN_D SWANBANK","SWAN_E SWANBANK","SYMEX PWR PLT UNIT 1","TABLELAND MILL 2","TAHMOOR WCM GAS PS","TAILEMBENDSOLARFARM1","TALLAWARRA B UNIT 1","TALLAWARRA1","TAMAR VALLEY  OCGT 4","TAMAR VALLEY CC 1","TARALGA WF","TARNL1 TARONG","TARONG BESS","TARONG#1 TARONG POWE","TARONG#2 TARONG POWE","TARONG#3 TARONG POWE","TARONG#4 TARONG POWE","TARRALEA TARRALEA","TATIARA BORDERTOWN 1","TB2 BESS ","TB2 BESS GEN","TB2 BESS LOAD","TB2 SOLAR GEN","TBLD TABLELAND MILL","TEA TREE LFG UNIT1","TEMP GEN NORTH","TEMP GEN SOUTH","TEMPLERS BESS","TERALBA TERALBA POWE","TERANG BESS","TERMSTOR TERMINAL ST","THE BLUFF WIND FARM","THE DROP HYDRO","TI TREE GEN 1","TIMWEST1","TNPS1 TARONG NORTH","TOMAGO1 TOMAGO SMELT","TOMAGO2 TOMAGO SMELT","TOMAGO3 TOMAGO SMELT","TOORAWF TOORA WIND F","TORNL1 TORRENS ISLAN","TORRA1 TORRENS ISLAN","TORRA2 TORRENS ISLAN","TORRA3 TORRENS ISLAN","TORRA4 TORRENS ISLAN","TORRB1 TORRENS ISLAN","TORRB2 TORRENS ISLAN","TORRB3 TORRENS ISLAN","TORRB4 TORRENS ISLAN","TORRENS IS BESS","TORRENS IS BESS GEN","TORRENS IS BESS LOAD","TOWER PW PLT UT 1-40","TRARALGON NET SS","TREVALLN TREVALLYN","TREV_1 TREVALLYN","TREV_2 TREVALLYN","TREV_3 TREVALLYN","TREV_4 TREVALLYN","TRIBNL1 TRIBUTE","TRIBUTE TRIBUTE","TULLY SUGAR MILL","TUMT3NL1 TUMUT3","TUMT3NL2 TUMUT3","TUMT3NL3 TUMUT3","TUMUT1-1 TUMUT1","TUMUT1-2 TUMUT1","TUMUT1-3 TUMUT1","TUMUT1-4 TUMUT1","TUMUT2-1 TUMUT2","TUMUT2-2 TUMUT2","TUMUT2-3 TUMUT2","TUMUT2-4 TUMUT2","TUMUT3 TUMUT3","TUMUT3-1 TUMUT3","TUMUT3-2 TUMUT3","TUMUT3-3 TUMUT3","TUMUT3-4 TUMUT3","TUMUT3-5 TUMUT3","TUMUT3-6 TUMUT3","TUNGATIN TUNGATINAH","TUNGA_3 TUNGATINAH","TUNGA_4 TUNGATINAH","TYPHOONW HRL TRAMWAY","Tatura Unit 1","ULINDAPARKBESS1","UPPTUMUT UPPTUMUT","URANQUINTY UNIT 11","URANQUINTY UNIT 12","URANQUINTY UNIT 14","URANQUNITY UNIT 13","UWS1 UWS CO-GEN UNIT","VALLEY POWER UNIT 1","VALLEY POWER UNIT 2","VALLEY POWER UNIT 3","VALLEY POWER UNIT 4","VALLEY POWER UNIT 5","VALLEY POWER UNIT 6","VBB BESS","VBB GENERATOR","VBB LOAD","VICSMLT VICTORIAN SM","VICSMLT2 VICTORIAN S","VICTORIA MILL U 3&4","VP5 VALES POINT B PO","VP6 VALES POINT B PO","VPGS","VPNL1 VP","VPP AGLE SA 1 VL1","VPP ENGLOC NSW2 SL1","VPP ENGLOC VIC2 SL1","VPP HT QLD 1 VL1","VPP SHINHUB SA 1 SL1","VPP SIMPLY SA 1 VL 1","VPP SONNEN NSW 1 VL1","VPP TESLAEL SA 1 VL1","W/HOE#1 WIVENHOE POW","W/HOE#2 WIVENHOE POW","WAGGA NORTH SF","WALLA WALLA SF 1","WALLA WALLA SF 2","WALLGROVE BESS","WALLGROVE BESS L1","WALLGROVE BESSG1","WAMBO WIND FARM 1","WANDOAN BESS","WANDOAN BESSGEN","WANDOAN BESSLOAD","WANDOAN STH SOLAR 1","WARATAHBESS1","WARWICK SOLAR FARM 1","WARWICK SOLAR FARM 2","WATERLOO WIND FARM 1","WAUBRA WF 128UNITS","WDBESS STAGE1","WDBESS STAGE1 BDU","WDBESS STAGE2 BDU","WDBESSL1","WELLINGTON NORTH SF","WELLINGTON SF","WEMEN SF","WEST SUB LEAGUES CLB","WEST WYALONG SF 1","WESTERN DOWNS GPH","WG01 WARRAGAMBA POWE","WGULLY WHYTES GULLY","WHILL1 WINDY HILL WI","WHIT1 WHITWOOD RD RE","WHITE ROCK SOLAR","WHITE ROCK WIND FARM","WHITSUNDAY SF","WILGA PARK B UNIT 1","WILGA PARK PS","WILLIAM HOVELL","WILLOGOLECHE WF","WINGFD 1  LFG U 1-4","WINGFD 2  LFG U 1-4","WINTON SF","WIVENSH WIVENHOE SMA","WKIEWA1 WEST KIEWA P","WKIEWA2 WEST KIEWA P","WNSF SOLAR","WOLLAR SF 1","WOLLERT REF","WONWP WONTHAGGI WIND","WOODLAWN BIO 1-6,7","WOODLAWN WIND FARM","WOOLNTH1 WOOLNORTH W","WOOLOOGA SOLAR FARM","WOY WOY LANDFILL PS","WPWF WATTLE POINT","WST ILLAWRA LGS CLB","WUNGHNU SF","WW7 WALLERAWANG POWE","WW8 WALLERAWANG POWE","WWNL1 WALLERAWANG PO","WYA252B1 LIAP, CATA,","WYALONG SOLAR FARM","WYANGALA A HYDRO PS","WYANGALA B HYDRO PS","WYB252B1 LIAP, CATA,","WYNDW WYNDHAM WASTE","YABULU YABULU","YABULU2 YABULU","YALOAK SOUTH WF","YAMBUKWF YAMBUK WIND","YARRANLEA SOLAR FARM","YARRAWONGA UNIT 1&2","YARWUN ALUMINA REF 1","YATPOOL SOLAR FARM","YAWONG WIND FARM","YENDON WIND FARM 1","YWNL1 YALLOURN","YWPS1 YALLOURN 'W' P","YWPS2 YALLOURN 'W' P","YWPS3 YALLOURN 'W' P","YWPS4 YALLOURN 'W' P"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2004/06/22 10:59:26"],"parse_csv_as_string":true,"is_s_datetime":true},"UNITTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Identifies LOAD, GENERATOR or BIDIRECTIONAL","examples":["BIDIRECTIONAL","GENERATOR","LOAD"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHABLEUNIT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":16906,"decompressed_size_all_time":16461220},"visibility":"Public","trigger":"When new units are added or names are changed"},"DISPATCHBIDTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#419"],"comment":"DISPATCHBIDTRK shows the bid tracking, including the bid version used in each dispatch run for each unit. DISPATCHBIDTRK is the audit trail of the bid actually used in each dispatch.","unused":true,"primary_keys":["DUID","OFFEREFFECTIVEDATE","OFFERVERSIONNO","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFEREFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of offer used","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Version no of offer used","is_integer":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no from 1 to 288 (as per bid)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (daily, default or rebid)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private & Public Next-Day","trigger":"Each dispatch run"},"DISPATCHBLOCKEDCONSTRAINT":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"BLOCKED_CONSTRAINTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#100"],"comment":"DISPATCH Blocked Constraints lists any constraints that were blocked in a dispatch run. If no constraints are blocked, there will be no rows for that dispatch run.","primary_keys":["CONSTRAINTID","RUNNO","SETTLEMENTDATE"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint identifier (synonymous with GenConID)","examples":["#R036712_001_RAMP_F","#R036712_001_RAMP_V","#R036733_002_RAMP_F","#R036733_002_RAMP_V","#R036760_001_RAMP_F","#R036760_001_RAMP_V","#R036761_001_RAMP_F","#R036761_001_RAMP_V"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch Interval","examples":["2026/09/01 00:10:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHBLOCKEDCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":9},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":649,"decompressed_size_all_time":288860},"visibility":"Public","trigger":"Each dispatch run (5 minutes)"},"DISPATCHCASESOLUTION":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"CASE_SOLUTION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#106"],"comment":"DISPATCHCASESOLUTION shows information relating to the complete dispatch run. The fields in DISPATCHCASESOLUTION provide an overview of the dispatch run results allowing immediate identification of conditions such as energy or FCAS deficiencies.","description":"The DISPATCHCASESOLUTION data is public.\n\nSource\n\nDISPATCHCASESOLUTION updates every 5 minutes.\n\nVolume\n\nApproximately 288 records per day.","primary_keys":["RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the dispatch interval (e.g. five minute dispatch interval ending 28/09/2000 16:35)","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"CASESUBTYPE":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Categorical","mandatory":false,"comment":"Overconstrained dispatch indicator:\n* OCD = detecting over-constrained dispatch\n* null = no special condition","examples":["OCD"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention flag - refer to package documentation for definition and practical query examples","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of DISPATCHCASESOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"NONPHYSICALLOSSES":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Non-Physical Losses algorithm invoked occurred during this run","examples":["0"],"is_integer":true,"num_int_bits":8},"SOLUTIONSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"If non-zero indicated one of the following conditions:\n* 1 = Supply Scarcity, Excess generation or constraint violations\n* X = Model failure","examples":["0","1"],"is_integer":true,"num_int_bits":8},"SPDVERSION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Current version of SPD"},"SWITCHRUNBESTSTATUS":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating which Switch run was used for the Solution – from PeriodSolution","examples":["0","1"],"is_boolean":true},"SWITCHRUNBESTSTATUS_INT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating which Switch run was used for the Intervention Physical Solution - from PeriodSolution","is_boolean":true},"SWITCHRUNINITIALSTATUS":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating the SCADA status for FCAS Interconnector dead-band. \"0\" if SCADA Status or requesting Constraint not invoked. \"1\" if SCADA Status AND requesting Constraint is invoked","examples":["0","1"],"is_boolean":true},"TOTAL5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 5 minute ancillary service region violations","is_float":true},"TOTAL6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 6 second ancillary service region violations","is_float":true},"TOTAL60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 60 second ancillary service region violations","is_float":true},"TOTALAREAGENVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Region Demand violations","examples":["0"],"is_float":true},"TOTALASPROFILEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of ancillary service trader profile violations","examples":["0"],"is_float":true},"TOTALENERGYOFFERVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of unit summated offer band violations","examples":["0"],"is_float":true},"TOTALFASTSTARTVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of fast start trader profile violations","examples":["0"],"is_float":true},"TOTALGENERICVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total generic constraint violations","examples":["0.045","0","3","40"],"is_float":true},"TOTALINTERCONNECTORVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total interconnector violations","examples":["0"],"is_float":true},"TOTALOBJECTIVE":{"sql_type":"NUMBER(27,10)","pl_type":"pl.Float64","mandatory":false,"comment":"The Objective function from the LP","examples":["-442000.132","287196.684","-87807790.044","9973272893.273"],"is_float":true},"TOTALRAMPRATEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total ramp rate violations","examples":["0.025","0","0.79"],"is_float":true},"TOTALREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of Regulation ancillary service region violations","is_float":true},"TOTALUNITMWCAPACITYVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total unit capacity violations","examples":["0.03","0","2","67"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHCASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":156703,"decompressed_size_all_time":204925200},"visibility":"Public","trigger":"Every 5 minutes"},"DISPATCHCASESOLUTION_BNC":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCHBNC","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#438"],"comment":"DISPATCHCASESOLUTION_BNC was discontinued on 30 September 2009. Prior: DISPATCHCASESOLUTION_BNC is the key data to indicate when a binding intra-regional network constraints (BNC) re-run actually occurred.","description":"DISPATCHCASESOLUTION_BNC was discontinued on 30 September 2009.\n\nIn accordance with the \"Arrangements for Managing Risks Associated with\nTransmission Network Congestion\" set of rule changes the Dispatch\nBinding Network Constraints re-run was discontinued on September 30,\n2009.\n\nSource\n\nThe occurrences of Over-constrained dispatch (OCD) or binding\nintra-regional network constraints (BNC) re-runs are ad hoc, with\nsignificant dependencies on the configuration or events in the physical\npower system. Potentially updated every 5 minutes.\n\nVolume\n\nRows per day: ~72\n\nMb per month: 25% of DISPATCHCASESOLUTION\n\nThe estimates on the number of rows are based on a 25% occurrence rate\nfor BNC runs.\n\nNote\n\nDue to the close dependency with the dispatch process, the OCD and BNC\ndata models use a “CaseSolution” key table in the same manner as\nDISPATCHCASESOLUTION.","unused":true,"primary_keys":["INTERVENTION","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Manual intervention flag","is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date and time of the dispatch interval","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"CASESUBTYPE":{"sql_type":"VARCHAR2(3)","pl_type":"pl.Categorical","mandatory":false,"comment":"always BNC"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NONPHYSICALLOSSES":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Non-Physical Losses algorithm invoked occurred during this run","is_integer":true,"num_int_bits":8},"SOLUTIONSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"If non-zero indicated one of the following conditions:\n* 1 = Supply Scarcity, Excess generation or constraint violations\n* X = Model failure","is_integer":true,"num_int_bits":8},"SPDVERSION":{"sql_type":"NUMBER(10,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Current version of SPD","is_float":true},"STARTPERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Period identifier of first interval of the case (yyyymmddppp)"},"TOTAL5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 5 minute ancillary service region violations","is_float":true},"TOTAL6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 6 second ancillary service region violations","is_float":true},"TOTAL60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 60 second ancillary service region violations","is_float":true},"TOTALAREAGENVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Region Demand violations","is_float":true},"TOTALASPROFILEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of ancillary service trader profile violations","is_float":true},"TOTALENERGYCONSTRVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"is_float":true},"TOTALENERGYOFFERVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of unit summated offer band violations","is_float":true},"TOTALFASTSTARTVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of fast start trader profile violations","is_float":true},"TOTALGENERICVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total generic constraint violations","is_float":true},"TOTALINTERCONNECTORVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total interconnector violations","is_float":true},"TOTALOBJECTIVE":{"sql_type":"NUMBER(27,10)","pl_type":"pl.Float64","mandatory":false,"comment":"The Objective function from the LP","is_float":true},"TOTALRAMPRATEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total ramp rate violations","is_float":true},"TOTALREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of Regulation ancillary service region violations","is_float":true},"TOTALUNITMWCAPACITYVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total unit capacity violations","is_float":true}},"visibility":"Public","trigger":"Adhoc, potentially every 5 minutes"},"DISPATCHCASE_OCD":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCHOCD","REPORT_SUB_TYPE":"CASE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#429"],"comment":"DISPATCHCASE_OCD shows the key data to indicate when an over-constrained dispatch (OCD) re-run actually occurred. One record per over-constrained dispatch interval.","description":"The DISPATCHCASE_OCD data is public.\n\nSource\n\nThe occurrences of Over-constrained dispatch (OCD) or binding\nintra-regional network constraints (BNC) re-runs are ad hoc, with\nsignificant dependencies on the configuration or events in the physical\npower system. Potentially updated every 5 minutes.\n\nVolume\n\nRows per day: ~2\n\nMb per month: \\<1\n\nThe estimates on the number of rows are based on a 1% occurrence rate\nfor OCD runs.\n\nNote\n\nDue to the close dependency with the dispatch process, the OCD and BNC\ndata models use a “CaseSolution” key table in the same manner as the\nDISPATCHCASESOLUTION table.","unused":true,"primary_keys":["RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date and time of the dispatch interval","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Adhoc, potentially every 5 minutes"},"DISPATCHCONSTRAINT":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"CONSTRAINT","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#115"],"comment":"DISPATCHCONSTRAINT sets out details of all binding and interregion constraints in each dispatch run. Note: invoked constraints can be established from GENCONSETINVOKE. Binding constraints show as marginal value >$0. Interconnector constraints are listed so RHS (SCADA calculated limits) can be reported.","description":"DISPATCHCONSTRAINT is public data, and is available to all participants.\n\nSource\n\nDISPATCHCONSTRAINT updates every five minutes.","primary_keys":["CONSTRAINTID","DISPATCHINTERVAL","INTERVENTION","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["SETTLEMENTDATE"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint identifier (synonymous with GenConID)","examples":["#BBATTERY1_E1","#BBATTERY1_E2","#BRAEMAR1_E","#CLRKCWF1_E1","#CLRKCWF2_E1","#COHUNSF1_E1","#ERB02_E1","#ERB02_E2","#GREENB1_E1","#GREENB1_E2","#LANCSF1_E1","#LNGS2_E1","#MCINTYR1_E1","#MOUSF1_E","#MTGELWF1_E","#R036712_001_RAMP_F","#R036712_001_RAMP_V","#RANGEB1_E1","#RANGEB1_E2","#SMCSF1_E","#WANDSF1_E","#WDBESS1_E1","#WDBESS1_E2","C_N_LIMOSF11_220","C_N_MULWASF1_025","C_N_NESBESS_150_G","C_N_NESBESS_150_L","C_N_QUORNP_019_L_H","C_N_QUORNP_080_G_H","C_N_WILLBES1_075_G","C_N_WILLBES1_075_L","C_N_WTAHB1_850_G","C_N_WTAHB1_850_L","C_Q_BRDDBES1_181_G","C_Q_BRDDBES1_181_L","C_Q_BRDDSF01_296","C_Q_BUSF1_078","C_Q_KIDSPHG1_000","C_Q_KIDSPHG2_000","C_Q_KIDSPHL1_000","C_Q_KIDSPHL2_000","C_Q_MUCRKSF1_120","C_Q_SNB01_250_L","C_Q_SNB01_260_G","C_V_GPWFWST_462","DATASNAP_DFS_LS","DATASNAP_DFS_NCAN","DATASNAP_DFS_NCWEST","DATASNAP_DFS_NNTH","DATASNAP_DFS_NSYD","DATASNAP_DFS_QCEN","DATASNAP_DFS_QCIND","DATASNAP_DFS_QFNQ","DATASNAP_DFS_QNTH","DATASNAP_DFS_QROSS","DATASNAP_DFS_QSTHE","DATASNAP_DFS_QSTHW","DATASNAP_DFS_Q_BCCP","DATASNAP_DFS_Q_BCRG","DATASNAP_DFS_Q_CLST","DATASNAP_DFS_Q_CLWU","DATASNAP_DFS_Q_LCCP","DATASNAP_DFS_Q_RGLC","DATASNAP_DFS_Q_TAMR","DATASNAP_DFS_Q_TAMR2","DATASNAP_DFS_SADL","DATASNAP_DFS_SNTH","DATASNAP_DFS_SRIV","DATASNAP_DFS_SSE","DATASNAP_DFS_SWNSW","DATASNAP_DFS_TNTH","DATASNAP_DFS_TNWEST","DATASNAP_DFS_TWCST","DATASNAP_DFS_T_FASH1","DATASNAP_DFS_T_GOCS1","DATASNAP_DFS_T_HAGT1","DATASNAP_DFS_T_PMHA1","DATASNAP_DFS_T_PMHA3","DATASNAP_DFS_T_SHGT","DATASNAP_DFS_T_SHPM","DATASNAP_DFS_T_TATU","DATASNAP_DFS_T_WALE","DATASNAP_DFS_VIC_SG","DATASNAP_DFS_VMEL","DATASNAP_DFS_V_BABE","DATASNAP_N_AR_LS_TE","DATASNAP_N_MUSW","DATASNAP_N_TAM","DATASNAP_PDID_1","DATASNAP_PDID_2","DATASNAP_PV_NSW","DATASNAP_PV_QLDCEN","DATASNAP_PV_QLDNORTH","DATASNAP_PV_QLDSOUTH","DATASNAP_PV_SA","DATASNAP_PV_TASNORTH","DATASNAP_PV_TASSOUTH","DATASNAP_PV_VIC","DATASNAP_TE_967_1","DATA_MMS_ALERT1","DSNAP_BU_PST1_TAP","DSNAP_BU_PST2_TAP","DSNAP_BU_PST3_ANG","DSNAP_BU_PST3_TAP","DSNAP_BU_PST4_TAP","DSNAP_BU_PST5_TAP","DSNAP_DFS_N_ARTW","DSNAP_DFS_N_AVMN","DSNAP_DFS_N_BYCR","DSNAP_DFS_N_BYSW","DSNAP_DFS_N_CNYS","DSNAP_DFS_N_DTMN","DSNAP_DFS_N_LDTW","DSNAP_DFS_N_LTMS","DSNAP_DFS_N_MNYS","DSNAP_DFS_N_MSUT","DSNAP_DFS_N_TWUL","DSNAP_DFS_V_BABE_5M","DSNAP_DFS_V_BAML","DSNAP_DFS_V_BAML_5M","DSNAP_DFS_V_DDMB","DSNAP_DFS_V_DDMS","DSNAP_DFS_V_DDSM","DSNAP_DFS_V_EPTT","DSNAP_DFS_V_MLGT1","DSNAP_DFS_V_MLGT2","DSNAP_DFS_V_ROYP","DSNAP_INFO_NSW_INER","DSNAP_INFO_QLD_INER","DSNAP_INFO_SA_INER","DSNAP_INFO_SA_SYNCON","DSNAP_INFO_TAS_INER","DSNAP_INFO_TNTH_INER","DSNAP_INFO_VIC_INER","DSNAP_LLHS_1","DSNAP_LLHS_2","DSNAP_LRHS_1","DSNAP_LRHS_2","DSNAP_MLGT_MLGT_CONT","DSNAP_MLGT_MLGT_HC","DSNAP_MLGT_MLGT_LB","DSNAP_MLNK_RAT_LIM","DSNAP_N::N_NIL_LTWG","DSNAP_N>>NIL_85_86_S","DSNAP_N>>NIL_86_85_S","DSNAP_N_MSL_BESS_CHG","DSNAP_Q>>MITUM","DSNAP_Q>WOCY_1","DSNAP_Q>WOGP","DSNAP_Q^^NIL_TR_CLHA","DSNAP_Q^^NIL_TR_TRBK","DSNAP_Q_BKSP838","DSNAP_Q_MSL_BESS_CHG","DSNAP_Q_TR_1500","DSNAP_RACOMIL_GEN","DSNAP_SVML","DSNAP_S_MSL_BESS_CHG","DSNAP_TABMILL2_GEN","DSNAP_T_TV_BL_DYN","DSNAP_T_VT_BL_DYN","DSNAP_VS_600_TEST","DSNAP_V^^_NIL_SWVIC1","DSNAP_V^^_NIL_SWVIC2","DSNAP_V^^_NIL_SWVIC3","DSNAP_V^^_NIL_SWVIC4","DSNAP_V_MSL_BESS_CHG","D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_NIL_SNOW_N+S_100","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_TL_L1_DS","D_T+NIL_WF_TG_R1","D_V_HEYWOOD_OFGS_1","D_V_HEYWOOD_OFGS_2","D_V_HEYWOOD_OFGS_3","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_TL_L5_DS","F_T+NIL_TL_L60_DS","F_T+NIL_TL_L6_DS","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6","I_6F_NS_150","I_6F_SN_150","N::N_NIL_63","N::Q_BWMP_KC","N::Q_BWMP_LDMU","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N::Q_NIL_KC","N::Q_NIL_LDMU","N::Q_NIL_LDTW","N::Q_NIL_TNT","N::V_NIL_BWSW","N::V_NIL_MSDD","N::V_NIL_UTMS","N:V_NIL_BWRG","N:V_NIL_BYYS","N>94T_945_94K","N>94T_947_72","N>94T_94K1_945","N>>BWMP_23_22","N>>BWMP_81_31","N>>BWMP_81_82","N>>BWMP_82_81","N>>CHTX_966_87","N>>NIL_01_62","N>>NIL_060","N>>NIL_060_051","N>>NIL_07","N>>NIL_1","N>>NIL_16_18","N>>NIL_16_39","N>>NIL_16_3W","N>>NIL_16_76","N>>NIL_16_8","N>>NIL_18_16","N>>NIL_18_4_N","N>>NIL_18_4_S","N>>NIL_18_5_N","N>>NIL_18_5_S","N>>NIL_18_61","N>>NIL_18_8","N>>NIL_1_3","N>>NIL_1_3_LSC1_ON","N>>NIL_1_6X","N>>NIL_1_6X_LSC1_ON","N>>NIL_1_7","N>>NIL_1_7_LSC1_ON","N>>NIL_23_22","N>>NIL_23_25","N>>NIL_3","N>>NIL_33_34","N>>NIL_39","N>>NIL_39_11","N>>NIL_39_17","N>>NIL_3G","N>>NIL_3L","N>>NIL_3L_18_N","N>>NIL_3L_3J_N","N>>NIL_3L_3P_N","N>>NIL_3L_3W","N>>NIL_3L_5_N","N>>NIL_3_7","N>>NIL_3_7_LSC1_ON","N>>NIL_3_7_LSC2_ON","N>>NIL_4","N>>NIL_4_18_S","N>>NIL_4_5_N","N>>NIL_4_5_S","N>>NIL_4_61_N","N>>NIL_4_61_S","N>>NIL_4_6_S","N>>NIL_5_18_N","N>>NIL_5_18_S","N>>NIL_5_3J_N","N>>NIL_5_3L_N","N>>NIL_5_3P_N","N>>NIL_5_3W","N>>NIL_5_4_S","N>>NIL_5_61_N","N>>NIL_5_61_S","N>>NIL_5_6_S","N>>NIL_61_18","N>>NIL_61_3L","N>>NIL_61_3W","N>>NIL_61_4","N>>NIL_61_5","N>>NIL_64_65","N>>NIL_6M_66","N>>NIL_6X","N>>NIL_6X_1","N>>NIL_6X_3","N>>NIL_6X_9","N>>NIL_70_71","N>>NIL_76_77","N>>NIL_77_76","N>>NIL_7_1","N>>NIL_7_1_LSC1_ON","N>>NIL_7_3","N>>NIL_7_3_LSC1_ON","N>>NIL_7_3_LSC2_ON","N>>NIL_81","N>>NIL_81_31","N>>NIL_81_82_CLOSE","N>>NIL_81_82_OPEN","N>>NIL_82","N>>NIL_82_81_CLOSE","N>>NIL_82_81_OPEN","N>>NIL_83_84_CLOSE","N>>NIL_83_84_OPEN","N>>NIL_84_83_CLOSE","N>>NIL_84_83_OPEN","N>>NIL_84_88_S","N>>NIL_85_86_S","N>>NIL_86_85_N","N>>NIL_86_85_S","N>>NIL_86_8U_S","N>>NIL_86_N","N>>NIL_86_NIL_S","N>>NIL_88_84_N","N>>NIL_88_84_S","N>>NIL_8E_8C_S","N>>NIL_8U_86_S","N>>NIL_8_16","N>>NIL_8_18","N>>NIL_8_3W","N>>NIL_964_84_S","N>>NIL_964_88_S","N>>NIL_966/1_87_S","N>>NIL_967_89_S","N>>NIL_990","N>>NIL_990_051_S","N>>NIL_991","N>>NIL_994","N>>NIL_996_62","N>>NIL_99M_051_S","N>>NIL_9W2_9W8","N>>NIL_9_18_N","N>>NIL_9_18_S","N>>NIL_9_6","N>>NIL_DPTX_HV","N>>NIL_DPTX_LV","N>>NIL_X3_060","N>>V_NIL_65","N>>V_NIL_65_66","N>>V_NIL_65_LTWG","N>>V_NIL_66","N>>V_NIL_66_65","N>>V_NIL_66_LTWG","N>N-NIL_TE_LOAD","N>NIL_051","N>NIL_64_S","N>NIL_6M_N","N>NIL_75_WOTX_72","N>NIL_8J_8C","N>NIL_901","N>NIL_945_947","N>NIL_947_94T","N>NIL_94B","N>NIL_94K_1","N>NIL_94M","N>NIL_94T","N>NIL_94T_72","N>NIL_94T_75","N>NIL_94T_7J","N>NIL_94T_947","N>NIL_967_89","N>NIL_969","N>NIL_96C_87","N>NIL_970_051_S","N>NIL_973","N>NIL_977_976","N>NIL_983_987","N>NIL_997/1_3G","N>NIL_997/2_3G","N>NIL_997/2_99A","N>NIL_997_99A","N>NIL_998","N>NIL_998_18","N>NIL_999","N>NIL_999_9GL","N>NIL_999_S","N>NIL_99F","N>NIL_99U","N>NIL_9GL","N>NIL_9GM","N>NIL_9J5/1","N>NIL_9J5/2","N>NIL_9J6","N>NIL_9ML","N>NIL_9R1","N>NIL_9R4","N>NIL_9R4_62","N>NIL_9R4_99A","N>NIL_9R4_9R3","N>NIL_9R5","N>NIL_9R5_9R6","N>NIL_9R5_9R6_N","N>NIL_9R6","N>NIL_9R6_991","N>NIL_9R6_9R5","N>NIL_9R6_9R5_N","N>NIL_9U3","N>NIL_9U9_9U8","N>NIL_BHTX_HV","N>NIL_BHTX_LV","N>NIL_CLDP","N>NIL_LSDU","N>NIL_MBDU","N>NIL_PKTX_LV","N>NIL_X2","N>NIL_YSTX_LV","N>Q-NIL_757_758","NQTE_ROC","NQ_950_DYN_TEST","NQ_950_TEST","NRM_NSW1_QLD1","NRM_NSW1_VIC1","NRM_QLD1_NSW1","NRM_SA1_VIC1","NRM_TAS1_VIC1","NRM_VIC1_NSW1","NRM_VIC1_SA1","NRM_VIC1_TAS1","N^^N_NIL_1","N^^N_NIL_WGLT","N^^N_NIL_X5_BEKG","N^^N_NIL_X5_BESH","N^^Q_NIL_CPP_3","N^^Q_NIL_CPP_4","N^^Q_NIL_KPP_1","N^^Q_NIL_MAXGEN","N^^Q_NIL_MPP_1","N^^Q_NIL_MPP_2","N^^Q_NIL_TNPS1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_NIL_TE_A","N_NIL_TE_B","N_V_HV1700_OSC_AUTO","N_WDR_NO_SCADA","Q:NIL_CS","Q>>NIL_MRTX1_MRGB","Q>>NIL_MRTX4_MRTX5","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q>NIL_BCCP_CLWU","Q>NIL_BCCP_LCCP","Q>NIL_BCRG_BCCP","Q>NIL_BCRG_CLWU","Q>NIL_BCST_BCST","Q>NIL_BI_FB","Q>NIL_CLBTX_CLBTX","Q>NIL_CLWU_BCRG","Q>NIL_CLWU_LCCP","Q>NIL_CPWU_CLWU","Q>NIL_DRLCLB_NIL","Q>NIL_LCCP_BCCP","Q>NIL_LCCP_CLWU","Q>NIL_MRTA_A","Q>NIL_MRTA_B","Q>NIL_MRTA_C","Q>NIL_MUTE_757","Q>NIL_MUTE_758","Q>NIL_MUTX_MUTX","Q>NIL_PWSP_WOSP","Q>NIL_RGLC_BCCP","Q>NIL_RGLC_CLWU","Q>NIL_TV66","Q>NIL_WOPW_WOSP","Q>NIL_WOSP_PWSP","Q>NIL_WOSP_WOPW","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","QNTE_ROC","QN_1400_DYN_TEST","QN_1400_TEST","Q^CN_FDR-060","Q^CN_GT-090","Q^CS_-080","Q^NIL_CN_FDR","Q^NIL_CN_GT","Q^NIL_CS","Q^NIL_FNQ_8905","Q^NIL_GC","Q^^NIL_TR_CLHA","Q^^NIL_TR_TRBK","Q^^N_NIL_SRAR","Q^^TR_CLHA_-050","Q^^TR_CLHA_-350","Q^^TR_TRBK_-050","Q^^TR_TRBK_-100","Q_CS_2000","Q_KEP-HYB_50MW","Q_STR_NIL_KEP","Q_STR_NIL_KEP_I","S::V_NIL_TBSE_1","S::V_NIL_TBSE_2-DS","S:VS_580_OSC_AUTO_1","S:VS_700_1","S:VS_700_OSC_AUTO","S:VS_800","S:VS_900_HY_TEST","S:VS_900_HY_TEST_DYN","S:V_460_OSC_AUTO_1","S:V_550_1","S:V_550_OSC_AUTO","S:V_650","S:V_700_HY_TEST","S:V_700_HY_TEST_DYN","S>>HUWT_BRTX_MNWT","S>>HUWT_BWPA_BRTW","S>>HUWT_BWPA_TWPA","S>>HUWT_RBTU_WEWT","S>>NIL_BGBW_BRTW","S>>NIL_BRTW_WEMW4","S>>NIL_BRTW_WTTP","S>>NIL_BRTX_WEMW4","S>>NIL_BRTX_WTTP","S>>NIL_BWMP_BRTW","S>>NIL_BWMP_RBTU","S>>NIL_BWMP_TPRS","S>>NIL_BWMP_TWPA","S>>NIL_BWMP_WEMW4","S>>NIL_BWMP_WTTP","S>>NIL_CNRB_WEMW4","S>>NIL_HUBG-T_WEWT","S>>NIL_LKDV_WEWT","S>>NIL_MKRB_WEMW4","S>>NIL_RBNW1_MWP1NWB","S>>NIL_RBNW1_RBMWP3","S>>NIL_RBTU_BRTW","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_TWPA","S>>NIL_RBTU_WEWT","S>>NIL_RBTU_WTTP","S>>NIL_RBTX1_WTWE","S>>NIL_RBTX_RBTX_1","S>>NIL_RBTX_RBTX_2","S>>NIL_SETB_SETB_1","S>>NIL_TBSE_PWSE_1","S>>NIL_TBSE_TBSE_1","S>>NIL_TBTU_TBMO_1","S>>NIL_TBTU_TBTU_1","S>>NIL_TBTX4_TBMO_1","S>>NIL_TPWTX_TPDR","S>>NIL_TUTB_MOTB_1","S>>NIL_TUTB_TUTB_1","S>>NIL_TWPA_BWMP","S>>NIL_TWPA_TPRS","S>>NIL_TWPA_WEMW4","S>>V_NIL_DVBG_STBG","S>>V_NIL_NIL_HUWT","S>>V_NIL_NIL_MNWT","S>>V_NIL_NIL_MW1NWB","S>>V_NIL_NIL_RBMW3","S>>V_NIL_NIL_RBNW1","S>>V_NIL_RBTX_WEMW4","S>>V_NIL_WTTP_WEMW4","S>HUWT_BGTX_RHBR-T","S>HUWT_BWPA_RHBR-T","S>HUWT_NIL_STBG-T","S>NIL_ACPA_MAMO","S>NIL_BRTW_MNWT","S>NIL_BWMP_CNRB","S>NIL_BWMP_HUWT","S>NIL_BWMP_RHBR-T","S>NIL_DVBG_BRTW","S>NIL_DVTX_DVTX","S>NIL_HUWT_STBG","S>NIL_LKDV_CNRB","S>NIL_MHNW1_MHNW2","S>NIL_NIL_DLAW","S>NIL_NIL_MHNW2","S>NIL_NIL_MYSG-T","S>NIL_NIL_NWMH2","S>NIL_NIL_SETX12","S>NIL_NIL_SGBN","S>NIL_NIL_SGMYSE-T2","S>NIL_NWMH1_NWMH2","S>NIL_NWRB1_MWP3RB","S>NIL_NWRB2_NWRB1","S>NIL_RBMWP3_RBNW1","S>NIL_SGBN_SGSE-T","S>NIL_SGBN_SGSE-T2","S>NIL_TINO3_TINO4","S>NIL_WEMW4_WTTP","S>V_NIL_SEHY","S>V_NIL_SETX_SETX","S>V_NIL_SETX_SETX1","SVML^NIL_MH-CAP_ON","SVML_233","SVML_RAT_LIM_DYN","SVML_ROC_80","SVML_ZERO","SV_HEY_600_TEST","S^NIL_SA_NORTH","S_LB2WF_CONF","S_NIL_STRENGTH_1","S_V_HEYWOOD_OFGS","S_V_NIL_ROCOF","T::T_NIL_1","T::T_NIL_3","T>>T_NIL_BL_EXP_3F","T>>T_NIL_BL_EXP_3G","T>>T_NIL_BL_EXP_3H","T>>T_NIL_BL_EXP_4E","T>>T_NIL_BL_EXP_4F","T>>T_NIL_BL_EXP_5F","T>>T_NIL_BL_EXP_5G","T>>T_NIL_BL_EXP_5H","T>>T_NIL_BL_EXP_6E","T>>T_NIL_BL_EXP_6F","T>>T_NIL_BL_EXP_7C","T>T_NIL_110_4","T>T_NIL_110_5","T>T_NIL_BL_110_2","T>T_NIL_BL_110_3","T>T_NIL_BL_110_4","T>T_NIL_BL_110_5","T>T_NIL_BL_110_8_1","T>T_NIL_BL_110_9","T>T_NIL_BL_220_6B","T>T_NIL_BL_220_6C","T>T_NIL_BL_220_6D","T>T_NIL_BL_3A","T>T_NIL_BL_3B","T>T_NIL_BL_3C","T>T_NIL_BL_3D","T>T_NIL_BL_3E","T>T_NIL_BL_4A","T>T_NIL_BL_4B","T>T_NIL_BL_4C","T>T_NIL_BL_4D","T>T_NIL_BL_5A","T>T_NIL_BL_5B","T>T_NIL_BL_5C","T>T_NIL_BL_5D","T>T_NIL_BL_5E","T>T_NIL_BL_6A","T>T_NIL_BL_6B","T>T_NIL_BL_6C","T>T_NIL_BL_6D","T>T_NIL_BL_IMP_2B","T>T_NIL_BL_IMP_3F","T>T_NIL_BL_IMP_3FF","T>T_NIL_BL_IMP_3G","T>T_NIL_BL_IMP_3H","T>T_NIL_BL_IMP_4E","T>T_NIL_BL_IMP_4EE","T>T_NIL_BL_IMP_4F","T>T_NIL_BL_IMP_5F","T>T_NIL_BL_IMP_5FF","T>T_NIL_BL_IMP_5G","T>T_NIL_BL_IMP_5H","T>T_NIL_BL_IMP_6E","T>T_NIL_BL_IMP_6EE","T>T_NIL_BL_IMP_6F","T>T_NIL_BL_IMP_7C","T>T_NIL_BL_IMP_7CC","T>T_NIL_BL_IMP_8B","T>T_NIL_BL_IMP_8C","T>T_NIL_NCSPS5_3F","T>T_NIL_NCSPS5_3FF","T>T_NIL_NCSPS5_3G","T>T_NIL_NCSPS5_3H","T>T_NIL_NCSPS5_7C","T>T_NIL_TOV_5F","T>T_NIL_TOV_5FF","TVBL_NIL_CONT_459","TVBL_NIL_DYN","TVBL_ROC","T^T_NIL_BL_1","T^T_NIL_BL_2","T^T_NIL_BL_4","T^T_NIL_BL_5","T^T_NIL_BL_6","T^T_NIL_BL_7","T^V_NIL_10","T^V_NIL_11","T^V_NIL_8","T^V_NIL_9","T^V_NIL_BL_6","T_BLINK_TV_NGZ","T_BLINK_VT_NGZ","T_ROCOF_1","T_ROCOF_2","T_ROCOF_3_1","T_ROCOF_3_2","T_ROCOF_3_3","T_V_FCSPS_DS","T_V_NIL_BL1","T_V_NIL_FCSPS","V::N_NIL_O1","V::N_NIL_O2","V::N_NIL_V1","V::N_NIL_V2","V::S_NIL_MAXG_1","V::S_NIL_MAXG_2","V::S_NIL_MAXG_3","V::S_NIL_TBSE_1","V::S_NIL_TBSE_2","V::V_1900","V:SS_680_OSC_AUTO","V:SS_790_1","V:SS_790_OSC_AUTO","V:SS_920","V:SS_970_HY_TEST","V:SS_970_HY_TEST_DYN","V:S_460_OSC_AUTO","V:S_570_1","V:S_570_OSC_AUTO","V:S_700","V:S_750_HY_TEST","V:S_750_HY_TEST_DYN","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DBL_MSDD_MSDD","V>>DBL_MSDD_MSDD_SIP","V>>DBT_DDTX1_DDTX","V>>DBT_DDTX2_DDTX","V>>DBT_DDTX3_DDTX","V>>DDTX1_3_DDTX2_NIL","V>>DDTX2_3_DDTX1_NIL","V>>DDTX3_DDT1_DD2_LH","V>>DDTX3_DDT2_DD1_LH","V>>DDTX3_DDTX1_DDTX2","V>>DDTX3_DDTX2_DDTX1","V>>DDTX_DDTX1_NIL_LH","V>>DDTX_DDTX2_NIL_LH","V>>KM_BABE_KMRC","V>>KM_BABE_KMRC_1","V>>NIL_ARTSTL_ARCW","V>>NIL_ARWB_KGBE","V>>NIL_ARWB_RCWEKG","V>>NIL_BABE_HOMRKM","V>>NIL_BABE_KMRC","V>>NIL_BABE_KMRC_1","V>>NIL_BABE_RCWEKO","V>>NIL_BABE_SHBE","V>>NIL_BABE_SHBE_5M","V>>NIL_BANBGR_ARCW","V>>NIL_BEBA_ARWBBA","V>>NIL_BEKG_HOMRKM","V>>NIL_BGRART_ARCW","V>>NIL_CWAR_KGBE","V>>NIL_DDSM_DDSM","V>>NIL_DDSM_DDSM_SIP","V>>NIL_DDTX1_NIL","V>>NIL_DDTX2_NIL","V>>NIL_DDTX3_NIL","V>>NIL_ELML_BAML2","V>>NIL_EPTT_DDSM_SIP","V>>NIL_HYSE_HYSE","V>>NIL_KGWE_HOMRKM","V>>NIL_MBDD_MBDD","V>>NIL_MLGT_MLGT","V>>NIL_MLSY_MLSY","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD1_MSDD2_S","V>>NIL_MSDD2_MSDD1","V>>NIL_MSDD2_MSDD1_S","V>>NIL_RCWE_BUBD","V>>NIL_RCWE_HOBUCW","V>>NIL_RCWE_HOMRKM","V>>NIL_SMDD_SMDD","V>>NIL_SMTX_SMTX_R2","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>NIL_WEKG_HOBUCW","V>>NIL_WEKG_HOMRKM","V>>NIL_WERC_HOMRKM","V>>NSWRB_BEKG_X3","V>>NSWRB_BEKG_X5","V>>NSWRB_KGWE_X3","V>>NSWRB_KGWE_X5","V>>NSWRB_WERC_X3","V>>NSWRB_WERC_X5","V>>N_NIL_65","V>>N_NIL_65_051","V>>N_NIL_65_66","V>>N_NIL_66","V>>N_NIL_66_051","V>>N_NIL_66_65","V>>S_NIL_DVBG_DVBR","V>KM_WBBA_KMRC","V>KM_WBBA_KMRC_1","V>NIL_GNTX_GNTX","V>NIL_GNTX_GNTX_TEMP","V>NIL_TGTX_NIL","V>NIL_TGTX_TGTX_2","V>NIL_TGTX_TGTX_20S","V>NIL_WBBA_CWBUHO","V>NIL_WBBA_HOMRKM","V>NIL_WBBA_KMRC","V>NIL_WBBA_KMRC_1","V>NIL_WETX_NIL","V>NIL_YPRO7_YPHW1","V>NIL_YPRO7_YPRO8","V>S_NIL_SETX_SETX","VSML_220","VSML_RAT_LIM_DYN","VSML_ROC_80","VSML_VFRB_OFF","VSML_ZERO","VS_HEY_600_TEST","VS_HEY_650_TEST","VTBL_NIL","VTBL_NIL_CONT_441","VTBL_ROC","V^T_NIL_9","V^^N_NIL_1","V^^S_NIL_MAXG_1","V^^S_NIL_MAXG_2","V^^S_NIL_MAXG_3","V^^S_NIL_TBSE_1","V^^S_NIL_TBSE_2","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V^^V_NIL_KGTS_2","V_DUNDWF1_2_3_168","V_GANWR_SF_BAT_50","V_NWVIC_GFT1_750","V_SH_DD_MAC_FLT_965","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF","V_T_FCSPS_DS","V_T_NIL_BL1","V_T_NIL_FCSPS","V_WDR_NO_SCADA"],"is_categorical":true},"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP.","examples":["20260831241"],"is_integer":true,"num_int_bits":128},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Manual Intervention flag, which, if set (1), causes predispatch to solve twice.","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"DUID to which the Constraint is confidential. Null denotes non-confidential","examples":["BBATTERY1","BRAEMAR1","BRDDBES1","BRDDSF01","BUSF1","CLRKCWF1","CLRKCWF2","COHUNSF1","ERB02","GREENB1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","LANCSF1","LIMOSF11","LNGS2","MCINTYR1","MOUSF1","MTGELWF1","MUCRKSF1","MULWASF1","PPCCGT","RANGEB1","SMCSF1","SNB01","WANDSF1","WDBESS1","WILLBES1","WTAHB1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"name_in_csv":"CONFIDENTIAL_TO","is_categorical":true},"GENCONID_EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Effective date of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["2012/07/04 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID_VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Version number of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["1","2"],"is_integer":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregation of the constraints LHS term solution values","examples":["-0.14696","3.08403","0","380"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Value of binding constraint","examples":["-46.38658","0.01","0","5.38"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Right hand Side value as used in dispatch.","examples":["-0.0001","0.0001","0","20000"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Degree of violation in MW","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":177409194,"decompressed_size_all_time":186810144190},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes"},"DISPATCHINTERCONNECTORRES":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"INTERCONNECTORRES","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#126"],"comment":"DISPATCHINTERCONNECTORRES sets out MW flow and losses on each interconnector for each dispatch period, including fields for the Frequency Controlled Ancillary Services export and import limits and extra reporting of the generic constraints set the energy import and export limits.","description":"DISPATCHINTERCONNECTORRES is public data, and is available to all\nparticipants.\n\nSource\n\nDISPATCHINTERCONNECTORRES updates every 5 minutes.\n\nNote\n\nMW losses can be negative depending on the flow.\n\nThe definition of direction of flow for an interconnector is that\npositive flow starts from the FROMREGION in the INTERCONNECTOR table.","primary_keys":["DISPATCHINTERVAL","INTERCONNECTORID","INTERVENTION","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP.","examples":["20260831241","20260901119"],"is_integer":true,"num_int_bits":128},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention case or not","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"EXPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["#R036705_002_RAMP_F","#R036705_002_RAMP_V","F_T++NIL_ML_L6","I_6F_NS_150","N::Q_BWMP_LDTW","N>Q-NIL_757_758","NQTE_ROC","N^^N_NIL_WGLT","TVBL_ROC","T^V_NIL_9","T_V_NIL_BL1","V::N_NIL_O2","V::N_NIL_V2","V>>SMF2_SMF1_NIL_R5","VSML_ZERO","VS_HEY_600_TEST","V^^N_NIL_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy only.","examples":["-0.00001","0.87212","0","765"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + FCAS.","examples":["-0.00001","21.80078","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + FCAS.","examples":["-0.10156","0.00001","0","-2478"],"is_float":true},"IMPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["#R036705_002_RAMP_F","#R036705_002_RAMP_V","#R036705_006_RAMP_V","CA_SYDS_59A889E5_1","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R6","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R60","I_6F_SN_150","N>>NIL_85_86_S","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_966/1_87_S","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","QNTE_ROC","Q^^N_NIL_SRAR","S:V_700_HY_TEST","S:V_700_HY_TEST_DYN","SVML_ZERO","SV_HEY_600_TEST","T_BLINK_TV_NGZ","T_ROCOF_3_3","V::N_NIL_O2","V::N_NIL_V2","V>>BELML_BAML1_BAML2","V>>SMF2_SMF1_NIL_R5","VTBL_NIL_CONT_441","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V_T_NIL_BL1","V_T_NIL_FCSPS"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy only.","examples":["-0.10156","0.00001","0","-1243"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed.","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.02","4.36","0","-25"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.01","0","16","26912994"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor. Use this to adjust prices between regions.","examples":["0.66173","1.4908"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Shadow price resulting from thermal or reserve sharing constraints on Interconnector import/export (0 unless binding) - NEMDE Solution InterconnectorSolution element \"Price\" attribute","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Metered MW Flow from SCADA.","examples":["-0.3","0.3","0","224"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Target MW Flow for next 5 mins.","examples":["-0.59655","3.79883","0","765"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated MW Losses","examples":["-0.01194","0.01228","0","138.39845"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Degree of violation on interconnector constraints","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHINTERCONNECTORRES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1923202,"decompressed_size_all_time":2446783830},"visibility":"Public","trigger":"Every 5 minutes"},"DISPATCHLOAD":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":5},{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#135","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20_1.htm"],"comment":"DISPATCHLOAD set out the current SCADA MW and target MW for each dispatchable unit, including relevant Frequency Control Ancillary Services (FCAS) enabling targets for each five minutes and additional fields to handle the new Ancillary Services functionality. Fast Start Plant status is indicated by dispatch mode.","description":"DISPATCHLOAD data is confidential for the current day, showing own\ndetails for participant and becomes public after close of business\nyesterday, and is available to all participants.\n\nSource\n\nDISPATCHLOAD shows data for every 5 minutes for all units, even zero\ntargets.\n\nVolume\n\nExpect 40-50,000 records per day. All units are repeated, even zero\ntargets.\n\nNote\n\n\\*\\* A flag exists for each ancillary service type such that a unit\ntrapped or stranded in one or more service type can be immediately\nidentified. The flag is defined using the low 3 bits as follows:\n\n| Flag Name | Bit | Description                                                                                                                                                                                                     |\n|-----------|-----|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|\n| Enabled   | 0   | The unit is enabled to provide this ancillary service type.                                                                                                                                                     |\n| Trapped   | 1   | The unit is enabled to provide this ancillary service type, however the profile for this service type is causing the unit to be trapped in the energy market.                                                   |\n| Stranded  | 2   | The unit is bid available to provide this ancillary service type, however, the unit is operating in the energy market outside of the profile for this service type and is stranded from providing this service. |\n\nInterpretation of the bit-flags as a number gives the following\npossibilities (i.e. other combinations are not possible):\n\n| Numeric Value | Bit (2,1,0) | Meaning                                 |\n|---------------|-------------|-----------------------------------------|\n| 0             | 000         | Not stranded, not trapped, not enabled. |\n| 1             | 001         | Not stranded, not trapped, is enabled.  |\n| 3             | 011         | Not stranded, is trapped, is enabled.   |\n| 4             | 100         | Is stranded, not trapped, not enabled.  |\n\nFor example, testing for availability can be done by checking for odd\n(=available) or even (=unavailable) number (e.g. mod(flag,2) results in\n0 for unavailable and 1 for available).\n\n\\*\\*\\* \"Actual FCAS availability\" is determined in a post-processing\nstep based on the energy target (TotalCleared) and bid FCAS trapezium\nfor that interval. However, if the unit is outside the bid FCAS\ntrapezium at the start of the interval (InitialMW), the \"Actual FCAS\navailability\" is set to zero. For regulation services, the trapezium is\nthe most restrictive of the bid/SCADA trapezium values.","primary_keys":["DUID","INTERVENTION","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD01","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNAES1","ASNBRL1","ASNENC1","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSENC1","ASSERDV1","ASTHYD1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DPNTB1","DRACAN1","DRACAV1","DRAESN3","DRAESS1","DRBRLV01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DRHTVP03","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRVIOT07","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","RESS1","RIVNB2","ROMA_7","ROMA_8","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYGJP","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VENUS1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VSNEL2S1","VSQHT1V1","VSSAE1V1","VSSSE1V1","VSSSH1S1","VSVEL2S1","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention flag if intervention run","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date and time starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"AGCSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"AGC Status from EMS\n* 1 = on\n* 0 = off","examples":["0","1"],"is_integer":true,"num_int_bits":8},"AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Scheduled units, this is the MAXAVAIL bid availability For Semi-scheduled units, this is the lower of MAXAVAIL bid availability and UIGF","examples":["0.3295","0","1","1473"],"is_float":true},"CONFORMANCE_MODE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mode specific to units within an aggregate. 0 - no monitoring, 1 - aggregate monitoring, 2 - individual monitoring due to constraint","examples":["0","1"],"is_integer":true,"num_int_bits":32},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier for DUID","examples":["AKWB1W","NAL11C","NAL12M","NASACA01","NASAGL03","NASENG01","NASGRD01","NASGRU01","NASHYD01","NASSHU01","NASSHU02","NASVTA01","NASYES01","NBA21B","NBAY1","NBAY2","NBAY3","NBAY4","NBB21B","NBES1B","NBK11B","NBKB3B","NBKW1S","NBL21L","NBLW8","NBOD1B","NBSF1L","NBSF2S","NCDS1C","NCKW1C","NCLG1D","NCLG2D","NCLG3D","NCLG4D","NCLS1C","NCLW1C","NCMA3B","NCRN1C","NCW31C","NCWF2W","NDNH1H","NDNS1D","NDNSG","NDT13T","NDTB1T","NEPS1","NEPS2","NEPS3","NEPS4","NER21E","NERB1E","NFBS1J","NFNS1F","NGJP","NGNE1G","NGUR1G","NGUR2G","NGUR3G","NGUT8","NHLB1S","NHUM","NJDA1G","NLDB1L","NLMB1L","NLTS3","NLTS8","NMLS1M","NMOS1M","NMR22T","NMR41M","NMTP1","NMTP2","NMTZ1M","NMUR8","NMWB1W","NNCP1H","NNCP2H","NNEE1H","NNRN1A","NONF1F","NPG11P","NPG12G","NPKQ1Q","NPKQ2Q","NQBB3Q","NQBC3C","NRB23R","NRBB3R","NRDP3D","NRPK1R","NRT1","NRTAMAL1","NRTBORA1","NRTENOC1","NRTNEM02","NRTNEM03","NRTNEM04","NRTNEM05","NRTNEM06","NSAP1S","NSHL","NSHP1","NSTB1S","NSTU1S","NSWB3W","NSYW1","NURB1N","NURB2N","NURQ1U","NURQ2U","NURQ3U","NURQ4U","NURR1N","NURR2N","NUTS8","NVPEVER1","NVPP5","NVPP6","NWDENC01","NWDENC03","NWDENC04","NWDENC05","NWDENC06","NWDENC07","NWDENC09","NWDENC10","NWDENC11","NWDENC12","NWDENC13","NWDENC14","NWDENC16","NWDENC17","NWDENC19","NWDENC20","NWDVTA01","NWGG1W","NWGJ1J","NWGJ2S","NWGJ3W","NWGJ4W","NWGS1B","NWL21W","NWL82N","NWLA1W","NWLN1W","NWLO1O","NWLS3N","NWLS4W","NWLW1S","NWOW1W","NWRK1W","NWRK2W","NYS12A","QAFH1K","QAFH2K","QAFH3K","QAFH4K","QASDAL01","QASEEQ01","QASEQL01","QASPWR01","QASVTA01","QBCB3B","QBCG","QBCK1","QBCK2","QBDR1L","QBGH1","QBGH2","QBKB1S","QBLG1G","QBRA1","QBRA2","QBRA3","QBRA4K","QBRA5B","QBRA6B","QBRA7B","QBRA8D","QBRS1D","QBSS1B","QBSS2B","QBSW1C","QBSW2C","QCAB1","QCAB2","QCAC3","QCAC4","QCBF1D","QCBR1C","QCBS1B","QCCK1D","QCCK2H","QCLA1C","QCND1C","QCOS1C","QCPG1C","QDMR1W","QDMW1W","QDNSG","QGAR1","QGBB1G","QGLD1","QGLD2","QGLD3","QGLD4","QGLD5","QGLD6","QGNS1B","QHAR1H","QKAH1","QKAH2","QKAH3","QKAH4","QLCS1A","QLIS1E","QLIS2M","QLLV3C","QMPL1R","QMRR1M","QMRY1Y","QMRY2M","QMRY3W","QMRY4W","QMSP1","QMSP2","QMSP3M","QMSW1M","QOKY1","QOKY2","QORS1E","QRMA7","QRMA8","QROG1K","QROG3R","QROW1K","QROW2K","QROW3K","QROW4K","QRT1","QRTENOC1","QSLD1H","QSLS1W","QSPB1B","QSPS1S","QSPT1S","QSTB1S","QSTN1","QSTN2","QSTN3","QSTN4","QSWE","QTBS1C","QTBS2S","QTKS1O","QTKS2O","QTMW1K","QTNT","QTRB1T","QTRN1","QTRN2","QTRN3","QTRN4","QTRS1K","QTYP","QTZS1S","QVPHYDR1","QWDB3C","QWDE3W","QWDE4W","QWDENC02","QWDENC04","QWDR1W","QWDS1U","QWIP1","QWIP2","QWIV1","QWIV2","QWKM1M","QWLB1W","QWLM1M","QWLS1W","QWSB3W","QWSR1W","QWSR2W","QWSS1G","QYAG1R","SART2","SART3","SART4","SART5","SART6","SASAGL01","SASDSC01","SASENGY1","SASEQL01","SASGRD01","SASHYD01","SASPAP01","SASSHU01","SASSHU02","SASVTA01","SASYES01","SASYES02","SASYES03","SASYES04","SBEL1A","SBEL2P","SBEM1B","SBEM2B","SBLWS1","SBLWS2","SBPS1B","SBUA1B","SBYW1B","SCGB1C","SCGW1P","SCRK","SDAN3D","SDAP1P","SDAP2P","SDCA1","SDCA2","SDCA3","SDNSG","SDRN1","SHDW1H","SHDW2H","SHDW3H","SHPS1","SHPS2W","SHVA3H","SHVA4H","SLBB3L","SLGW1L","SLGW4L","SLGW5L","SMA21M","SMA31M","SMAB1M","SMAE1M","SMAY1","SMAY2","SMAY3W","SMH21M","SMOK1H","SMPS","SMTL3H","SMTM1","SMVE1","SMVE14","SMVE15","SMVE2","SMVE3P","SMVE6D","SMW11M","SMW21M","SMW31M","SMW41M","SNBN1","SNPT1S","SNWF1T","SPEW1","SPEW2","SPGG1B","SPGW2B","SPGW6B","SPL31P","SPLN1","SPPT","SQPS1","SQPS2","SQPS3","SQPS4","SQPS5Q","SRAB1G","SROB1G","SRT1","SRTAGLE1","SRTENOC1","SSGA1","SSNN1","SSYP1","STBB1T","STBB4T","STBS1T","STET1T","STPB3T","STSB2","STSB3","STSB4","SUMM1S","SUNN1S","SVPSHUB1","SWDENC02","SWDVTA01","SWGL1W","SWLE","TASFRM01","TASFRM02","TASVTA01","TBB11","TBB12","TBB13","TBB14A","TCE11","TDE11M","TDG11","TDNSG","TFA11","TFI11","TGH11G","TGO11","TJB11","TLE11","TLI11","TMA11","TMB11","TPM11","TPM21","TRCA1","TRCB1","TRT1","TRTHYDR1","TSH11","TTA11","TTI11","TTR11","TTU11","TTV11A","TWC11C","VAPD1","VART1A","VASACA01","VASACL01","VASBRA01","VASDAM01","VASENG01","VASEQL01","VASGRD01","VASGRD02","VASPBL01","VASPWR01","VASPWR02","VASSER01","VASVTA01","VAT21L","VAT22L","VBA23B","VBAW1Y","VBBT1B","VBBT2B","VBGT1B","VBGT4B","VCB33R","VCPT1C","VCWL1C","VDNSG","VDPS","VELT1M","VELT2M","VELT3E","VEPS1","VEPS2","VGET1G","VGN21G","VGN61M","VGNS1G","VGNS2W","VGP21G","VGP22G","VGPT1G","VGPT2G","VGPT3G","VGTW1M","VHGT1S","VHOG1K","VHUM","VHW23H","VICRT10","VICRT11","VICRT12","VICRT2","VICRT3","VICRT4","VICRT5","VICRT6","VICRT7","VICRT8","VICRT9","VJLGA1","VJLGA2","VJLGA3","VJLGA4","VJLGB1","VJLGB2","VJLGB3","VKGB3G","VKGP1K","VKGS1G","VKGS2C","VKMT1K","VKOT1K","VLYP010","VLYP011","VLYP012","VLYP07","VLYP08","VLYP09","VLYP1","VLYP2","VLYP3","VLYP4","VLYP5","VLYP6","VM041M","VM051D","VM052D","VM053D","VM0P1O","VM0P2O","VMKP1","VMLB3V","VMRT1M","VMRT2M","VMW61L","VMWT12","VMWT2","VMWT3","VMWT9B","VNPS","VPLT1P","VPR21M","VPR31M","VPRT1M","VRCS1K","VRCS2Y","VRT1","VRTENOC1","VSHS1N","VSHS2G","VSHS2W","VSHS3L","VSM71C","VTB21M","VTG21M","VTG31T","VTG61S","VTGT3A","VTR11H","VTR31R","VTRT1M","VTTS1","VVPEVER1","VWDENC01","VWDENC02","VWDENC03","VWDENC05","VWDENC06","VWDENC08","VWDENC09","VWES1B","VWES2W","VWKP1","VYP21","VYP22","VYP23","VYP24"],"is_categorical":true},"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP.","examples":["20260831241","20260831242"],"is_integer":true,"num_int_bits":128},"DISPATCHMODE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Dispatch mode for fast start plant (0 to 4).","examples":["0","4"],"is_integer":true,"num_int_bits":8},"DISPATCHMODETIME":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Minutes for which the unit has been in the current DISPATCHMODE. From NEMDE TRADERSOLUTION element FSTARGETMODETIME attribute.","examples":["0","5","7"],"is_integer":true,"num_int_bits":16},"ELEMENT_CAP":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Cap on the number of turbines or inverters at a DUID.","is_integer":true,"num_int_bits":32},"ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The projected energy storage based on cleared energy and regulation FCAS dispatch(MWh)","examples":["-0.54609","0.00203","0","363.65289"],"is_float":true},"INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The energy storage at the start of this dispatch interval(MWh)","examples":["0.14969","0","12","363.34692"],"is_float":true},"INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial MW at start of period. Negative values when Bi-directional Unit start from importing power, otherwise positive.","examples":["-0.02","0.00001","0","531"],"warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Lower1Sec - TraderSolution element L1Target attribute","examples":["22.25994","0","4","22.28513"],"is_float":true},"LOWER1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Lower 1Sec Availability","examples":["0","1","225"],"is_float":true},"LOWER1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element L1Flags attribute","examples":["0","1"],"is_boolean":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min reserve target","examples":["26.21425","0","2","114"],"is_float":true},"LOWER5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 5min availability","examples":["43.68254","0","1","236"],"is_float":true},"LOWER5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 5min status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec reserve target","examples":["16.18056","0","2","80"],"is_float":true},"LOWER6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 6sec availability","examples":["0.05263","0","1","225"],"is_float":true},"LOWER6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 6sec status flag ","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec reserve target","examples":["47.99176","0","1","114"],"is_float":true},"LOWER60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 60sec availability","examples":["1.5789","0","1","236"],"is_float":true},"LOWER60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 60sec status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation reserve target","examples":["0","3","100"],"is_float":true},"LOWERREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower reg availability","examples":["14.718009","0","2","415"],"is_float":true},"LOWERREGAVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Reg availability - minimum of bid and telemetered value","examples":["2.4","0","10","691"],"is_float":true},"LOWERREGENABLEMENTMAX":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Reg enablement Max point - minimum of bid and telemetered value","examples":["4.03761","0","1","1407"],"is_float":true},"LOWERREGENABLEMENTMIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Reg Enablement Min point - maximum of bid and telemetered value","examples":["-59.99988","0.0061","0","420"],"is_float":true},"LOWERREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower Reg status flag ","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"MIN_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only. Load side availability (BidOfferPeriod.MAXAVAIL where DIRECTION = LOAD)","examples":["0","2","473"],"is_float":true},"RAISE1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Raise1Sec - TraderSolution element R1Target attribute","examples":["35.86551","0","1","80"],"is_float":true},"RAISE1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Raise 1Sec Availability","examples":["0","1","225"],"is_float":true},"RAISE1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element R1Flags attribute","examples":["0","1"],"is_boolean":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min reserve target","examples":["0.19226","0","1","114"],"is_float":true},"RAISE5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 5min availability","examples":["0.1662","0","1","450"],"is_float":true},"RAISE5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0","1"],"is_integer":true,"num_int_bits":16},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec reserve target","examples":["0.19226","0","1","80"],"is_float":true},"RAISE6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 6sec availability","examples":["0.016447","0","1","450"],"is_float":true},"RAISE6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 6sec status flag ","examples":["0","1"],"is_boolean":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec reserve target","examples":["0.19226","0","1","80"],"is_float":true},"RAISE60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 60sec availability","examples":["0.168416","0","1","450"],"is_float":true},"RAISE60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 60sec status flag ","examples":["0","1"],"is_boolean":true},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation reserve target","examples":["5.84211","0","3","78"],"is_float":true},"RAISEREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise reg availability","examples":["3.38529","0","1","276"],"is_float":true},"RAISEREGAVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RaiseReg availability - minimum of bid and telemetered value","examples":["2.4","0","10","691"],"is_float":true},"RAISEREGENABLEMENTMAX":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RaiseReg enablement max point - minimum of bid and telemetered value","examples":["4.03761","0","1","1407"],"is_float":true},"RAISEREGENABLEMENTMIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RaiseReg Enablement Min point - maximum of bid and telemetered value","examples":["-59.99988","0.0061","0","420"],"is_float":true},"RAISEREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Raise Reg status flag ","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"RAMPDOWNRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp down rate used in dispatch (lesser of bid or telemetered rate).","examples":["0.18","0","60","20400"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp up rate (lesser of bid or telemetered rate).","examples":["1.55","0","6","20400"],"is_float":true},"SEMIDISPATCHCAP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Boolean representation flagging if the Target is Capped","examples":["0","1"],"is_boolean":true},"TOTALCLEARED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Target MW for end of period. Negative values when Bi-directional Unit is importing power, otherwise positive.","examples":["0.3295","0","-1","685"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Unconstrained Intermittent Generation Forecast value provided to NEMDE","examples":["0.3295","0","60","451.936"],"is_float":true},"VIOLATION5MINDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 5 min","is_float":true},"VIOLATION6SECDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 6 seconds","is_float":true},"VIOLATION60SECDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 60 seconds","is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW energy","is_float":true},"DOWNEPF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not Used","unused":true,"is_float":true},"MARGINAL5MINVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 5 min","unused":true,"is_float":true},"MARGINAL6SECVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 6 seconds","unused":true,"is_float":true},"MARGINAL60SECVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 60 seconds","unused":true,"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for energy","unused":true,"is_float":true},"TRADETYPE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Not used","examples":["0"],"unused":true,"is_integer":true,"num_int_bits":8},"UPEPF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not Used","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHLOAD%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":125211231,"decompressed_size_all_time":109007983150},"visibility":"Private & Public Next-Day","warnings":[{"msg":"If you only want power measurements, table DISPATCH_UNIT_SCADA is similar but far smaller.","category":"related_tables","level":"tip"},{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes for all units, even zero targets","pagination":["Elec20_1.htm"]},"DISPATCHLOAD_BNC":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCHBNC","REPORT_SUB_TYPE":"UNITSOLUTION","VERSION":1},{"REPORT_NAME":"DISPATCHBNC","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#447"],"comment":"DISPATCHLOAD_BNC was discontinued on 30 September 2009. Prior: DISPATCHLOAD_BNC gives binding intra-regional network constraints (BNC) re-run dispatch results for all scheduled generating units. DISPATCHLOAD_BNC has a similar structure to DISPATCHLOAD but does not repeat input type data (e.g. InitialMW, AGCStatus) since these values are available from DISPATCHLOAD.","description":"DISPATCHLOAD_BNC was discontinued on 30 September 2009.\n\nIn accordance with the \"Arrangements for Managing Risks Associated with\nTransmission Network Congestion\" set of rule changes the Dispatch\nBinding Network Constraints re-run was discontinued on September 30,\n2009.\n\nSource\n\nThe occurrences of Over-constrained dispatch (OCD) or binding\nintra-regional network constraints (BNC) re-runs are ad hoc, with\nsignificant dependencies on the configuration or events in the physical\npower system. Potentially updated every 5 minutes.\n\nDISPATCHLOAD_BNC shows data produced every 5 minutes for all units when\nthey have over-constrained dispatch, with own data being confidential\nuntil the next day.\n\nVolume\n\nRows per day: ~14000\n\nMb per month: 25% of DISPATCHLOAD\n\nThe basis of estimation on the number of rows is on a 25% occurrence\nrate for BNC runs\n\nNote\n\nA flag exists for each ancillary service type such that a unit trapped\nor stranded in one or more service type can be immediately identified.\nThe flag is defined as follows:\n\n| Flag Name | Bit | Description                                                                                                                                                                                                     | Field value |\n|-----------|-----|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|\n| Enabled   | 0   | The unit is enabled to provide this ancillary service type.                                                                                                                                                     | \\>1         |\n| Trapped   | 1   | The unit is enabled to provide this ancillary service type, however the profile for this service type is causing the unit to be trapped in the energy market.                                                   | 3           |\n| Stranded  | 2   | The unit is bid available to provide this ancillary service type, however, the unit is operating in the energy market outside of the profile for this service type and is stranded from providing this service. | 4           |","unused":true,"primary_keys":["DUID","INTERVENTION","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention flag if intervention run","is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date and time of the dispatch interval","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier for DUID","is_categorical":true},"DISPATCHMODE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Dispatch mode for fast start plant (0 to 4).","is_integer":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min reserve target","is_float":true},"LOWER5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 5min status flag","is_boolean":true},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec reserve target","is_float":true},"LOWER6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 6sec status flag","is_boolean":true},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec reserve target","is_float":true},"LOWER60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 60sec status flag","is_boolean":true},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation reserve target","is_float":true},"LOWERREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower Reg status flag","is_boolean":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min reserve target","is_float":true},"RAISE5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 5min status flag","is_boolean":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec reserve target","is_float":true},"RAISE6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 6sec status flag","is_boolean":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec reserve target","is_float":true},"RAISE60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 60sec status flag","is_boolean":true},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation reserve target","is_float":true},"RAISEREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise Reg status flag","is_boolean":true},"TOTALCLEARED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Target MW for end of period","is_float":true}},"visibility":"Private & Public Next-Day","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}]},"DISPATCHOFFERTRK":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"OFFERTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec21.htm#146"],"comment":"DISPATCHOFFERTRK is the energy and ancillary service bid tracking table for the Dispatch process. The table identifies which bids from BIDDAYOFFER and BIDOFFERPERIOD were applied for a given unit and bid type for each dispatch interval.","description":"DISPATCHOFFERTRK data is confidential to each participant until the next\ntrading day, when the data is public to all participants.\n\nSource\n\nDISPATCHOFFERTRK updates every 5 minutes.\n\nVolume\n\nApproximately 250,000 records per day.","primary_keys":["BIDTYPE","DUID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid type Identifier - the ancillary service to which the bid applies","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD01","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNAES1","ASNBRL1","ASNENC1","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSENC1","ASSERDV1","ASTHYD1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DPNTB1","DRACAN1","DRACAV1","DRAESN3","DRAESS1","DRBRLV01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DRHTVP03","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRVIOT07","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the dispatch interval (e.g. five minute dispatch interval ending 28/09/2000 16:35)","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BIDOFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Time this bid was processed and loaded","examples":["2020/09/14 15:09:17.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"BIDSETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Settlement date of bid applied","examples":["2020/09/14 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHOFFERTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":115576921,"decompressed_size_all_time":95274424260},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes"},"DISPATCHPRICE":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"PRICE","VERSION":4},{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"PRICE","VERSION":5}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec21.htm#157","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec21_1.htm"],"comment":"DISPATCHPRICE records 5 minute dispatch prices for energy and FCAS, including whether an intervention has occurred, or price override (e.g. for Administered Price Cap). DISPATCHPRICE updates when price adjustments occur, in which case the new price is written to the RRP field, and the old price to the ROP field as an audit trail.","description":"Source\n\nDISPATCHPRICE updates every 5 minutes.\n\nNote\n\nAPCFLAG is a 5-bit Region-based field indicating that the original\nDispatch Price (ROP) calculated by the Dispatch Algorithm for a region\nhas undergone modification by one of more of the following processes:\n\n| Bit | Value | Description                                         |\n|-----|-------|-----------------------------------------------------|\n| 5   | 16    | Price Scaling via Inter-regional Loss Factor (IRLF) |\n| 4   | 8     | Price manually overwritten                          |\n| 3   | 4     | MPC or MPF binding (ROP was outside of MPC/MPF)     |\n| 2   | 2     | VoLL Override applied                               |\n| 1   | 1     | APC or APF binding (ROP was outside of APC/APF)     |\n\nWhere:\n\n· MPC = Market Price Cap\n\n· MPF = Market Price Floor\n\n· APC = Administered Price Cap\n\n· APF = Administered Price Floor\n\nxxxAPCFLAGs are each a 5-bit Region-based field indicating FCAS price\npost-processing (where \"ROP\" is the original NEMDE Solver price):\n\n| Bit | Cum Value | Description                                                              |\n|-----|-----------|--------------------------------------------------------------------------|\n| 5   | 16        | Not applicable                                                           |\n| 4   | 8         | Price manually overwritten                                               |\n| 3   | 4         | MPC ($VoLL) or MPF ($zero) binding (xxFCAS ROP was outside of MPC/MPF) |\n| 2   | 2         | Not applicable                                                           |\n| 1   | 1         | APC or APF binding (ROP was outside of APC/APF)                          |","primary_keys":["DISPATCHINTERVAL","INTERVENTION","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"DISPATCHINTERVAL":{"sql_type":"VARCHAR2(22)","pl_type":"str","mandatory":true,"comment":"Dispatch interval identifier 001 to 288 in format YYYYMMDDPPP","examples":["20260831241","20260901152"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Manual intervention flag","examples":["0"],"is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date and time starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"APCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"APC Active flag (see note)","examples":["0"],"is_boolean":true},"CUMUL_PRE_AP_ENERGY_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["124507.15446","171432.43143"],"is_float":true},"CUMUL_PRE_AP_LOWER1_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["0.51","14.4"],"is_float":true},"CUMUL_PRE_AP_LOWER5MIN_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["60.26","66.59"],"is_float":true},"CUMUL_PRE_AP_LOWER6_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["54.33995","172.6667"],"is_float":true},"CUMUL_PRE_AP_LOWER60_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["100.74056","137.78236"],"is_float":true},"CUMUL_PRE_AP_LOWERREG_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["3259.85988","9224.75388"],"is_float":true},"CUMUL_PRE_AP_RAISE1_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["24.41","25","30.35","30"],"is_float":true},"CUMUL_PRE_AP_RAISE5MIN_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["19.89","20","40.43","40"],"is_float":true},"CUMUL_PRE_AP_RAISE6_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["66.95","96","387.99766","99"],"is_float":true},"CUMUL_PRE_AP_RAISE60_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["59.79","393.20851"],"is_float":true},"CUMUL_PRE_AP_RAISEREG_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cumulative price that triggers administered pricing event if above the threshold","examples":["6926.65486","9100.67947"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"BitFlag field for Price adjustments - \"1\" = Voll_Override; \"4\" = Floor_VoLL; \"8\" = Manual_Override; \"16\" = Price_Scaled","examples":["0"],"is_boolean":true},"LOWER1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.01","0"],"is_float":true},"LOWER1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Lower 1Sec Price - RegionSolution element L1Price attribute","examples":["0.01","0"],"is_float":true},"LOWER5MINAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"LOWER5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.25"],"is_float":true},"LOWER5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.25"],"is_float":true},"LOWER6SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"LOWER6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"LOWER6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"LOWER60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"LOWERREGAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"LOWERREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","1","50"],"is_float":true},"LOWERREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","1","50"],"is_float":true},"MARKETSUSPENDEDFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Market suspended flag","examples":["0"],"is_boolean":true},"MII_STATUS":{"sql_type":"VARCHAR2(21)","pl_type":"str","mandatory":false,"comment":"Communicates the current MII status for this dispatch interval. Values of: 'NOT_MII', 'MII_SUBJECT_TO_REVIEW', 'MII_PRICE_REJECTED', 'MII_PRICE_ACCEPTED'.","examples":["NOT_MII"]},"OCD_STATUS":{"sql_type":"VARCHAR2(14)","pl_type":"str","mandatory":false,"comment":"Communicates the current OCD status for this dispatch interval. Values of: 'NOT_OCD', 'OCD_UNRESOLVED', 'OCD_RESOLVED'.","examples":["NOT_OCD","OCD_RESOLVED"]},"PRE_AP_ENERGY_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["-0.00001","0.00001","0","90"],"is_float":true},"PRE_AP_LOWER1_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before AP capping or scaling - for Rolling Sum Price monitoring","examples":["0.01","0"],"is_float":true},"PRE_AP_LOWER5MIN_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","0.25"],"is_float":true},"PRE_AP_LOWER6_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","0.38"],"is_float":true},"PRE_AP_LOWER60_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","0.38"],"is_float":true},"PRE_AP_LOWERREG_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","1","50"],"is_float":true},"PRE_AP_RAISE1_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before AP capping or scaling - for Rolling Sum Price monitoring","examples":["0.01","0","0.04"],"is_float":true},"PRE_AP_RAISE5MIN_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","0.36"],"is_float":true},"PRE_AP_RAISE6_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0","0.38"],"is_float":true},"PRE_AP_RAISE60_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","0.38"],"is_float":true},"PRE_AP_RAISEREG_PRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price before ap capping or scaling - for rolling sum price monitoring","examples":["0.01","1","15.5","10"],"is_float":true},"PRICE_STATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Status of regional prices for this dispatch interval \"NOT FIRM\" or \"FIRM\"","examples":["FIRM"]},"RAISE1SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"BitFlag field for Price adjustments - \"1\" = Voll_Override; \"4\" = Floor_VoLL; \"8\" = Manual_Override; \"16\" = Price_Scaled","examples":["0"],"is_boolean":true},"RAISE1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.01","0","0.04"],"is_float":true},"RAISE1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Raise 1Sec Price - R1Price attribute after capping/flooring","examples":["0.01","0","0.04"],"is_float":true},"RAISE5MINAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"RAISE5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.36"],"is_float":true},"RAISE5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.36"],"is_float":true},"RAISE6SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"RAISE6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"RAISE6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","0.38"],"is_float":true},"RAISE60SECAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"RAISE60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0.38"],"is_float":true},"RAISE60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0.38"],"is_float":true},"RAISEREGAPCFLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["0"],"is_integer":true,"num_int_bits":16},"RAISEREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","1","15.5","10"],"is_float":true},"RAISEREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","1","15.5","10"],"is_float":true},"ROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Override Price, being the original price prior to any price scaling, price capping or VoLL override being applied. The APC flag allows the determination of whether capping, scaling or override occurred","examples":["-0.00001","0.00001","0","90"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price for this dispatch period. RRP is the price used to settle the market","examples":["-0.00001","0.00001","0","90"],"is_float":true},"EEP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess energy price - no longer used","examples":["0"],"unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHPRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1851106,"decompressed_size_all_time":2612154300},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes","pagination":["Elec21_1.htm"]},"DISPATCHREGIONSUM":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"REGIONSUM","VERSION":9}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec22.htm#166","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec22_1.htm","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec22_2.htm"],"comment":"DISPATCHREGIONSUM sets out the 5-minute solution for each dispatch run for each region, including the Frequency Control Ancillary Services (FCAS) services provided. Additional fields are for the Raise Regulation and Lower Regulation Ancillary Services plus improvements to demand calculations.","description":"DISPATCHREGIONSUM is public data, and is available to all participants.\n\nSource\n\nDISPATCHREGIONSUM updates every 5 minutes.\n\nNote\n\nFor details of calculations about load calculations, refer to Chapter 3\nof the \"Statement of Opportunities\"\n\n\\*\\*\\* \"Actual FCAS availability\" is determined in a post-processing\nstep based on the energy target (TotalCleared) and bid FCAS trapezium\nfor that interval. However, if the unit is outside the bid FCAS\ntrapezium at the start of the interval (InitialMW), the \"Actual FCAS\navailability\" is set to zero. For regulation services, the trapezium is\nthe most restrictive of the bid/SCADA trapezium values.\n\nFrom 16 February 2006, the old reserve values are no longer populated\n(i.e. are null), being LORSurplus and LRCSurplus. For more details on\nthe changes to Reporting of Reserve Condition Data, refer to AEMO\nCommunication 2042. For the best available indicator of reserve\ncondition in each of the regions of the NEM for each trading interval,\nrefer to the latest run of the Pre-Dispatch PASA (see table\nPDPASA_REGIONSOLUTION).","primary_keys":["DISPATCHINTERVAL","INTERVENTION","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP.","examples":["20260831241","20260901152"],"is_integer":true,"num_int_bits":128},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Manual Intervention flag","examples":["0"],"is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date and time starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"AGGEGATEDISPATCHERROR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated dispatch error","is_float":true},"AGGREGATEDISPATCHERROR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated dispatch error","examples":["-0.00614","0.02347","0","49.51466"],"is_float":true},"AVAILABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate generation bid available in region","examples":["1671.27364","15971.65707"],"is_float":true},"AVAILABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate load bid available in region","examples":["0","169","2681"],"is_float":true},"BDU_CLEAREDMW_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of export (Generation)","examples":["4.21292","0","1","823"],"is_float":true},"BDU_CLEAREDMW_LOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of import (Load)","examples":["15.27451","0","1","1395"],"is_float":true},"BDU_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated energy storage where the DUID type is BDU (MWh)","examples":["185.7941","5405.71733"],"is_float":true},"BDU_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy Storage for BDU at the start of the interval(MWh) - Region Aggregated","examples":["179.36054","5406.47666"],"is_float":true},"BDU_MAX_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available generation side BDU summated for region (MW)","examples":["70","2478"],"is_float":true},"BDU_MIN_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available load side BDU summated for region (MW)","examples":["45","2440"],"is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of cleared generation and import for region","examples":["931.88","940","8820.8","6893"],"is_float":true},"DECGEN_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy storage for Daily Energy Constrained Scheduled Generating Units at the start of the interval(MWh) - Region Aggregated","is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["1018.48938","8963.13913"],"is_float":true},"DEMANDFORECAST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"5 minute forecast adjust","examples":["0","-1","1","113"],"is_float":true},"DISPATCHABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Generation","examples":["513.96","850","7996.34","7070"],"is_float":true},"DISPATCHABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Load (add to total demand to get inherent region demand).","examples":["15.27","0","1","1638"],"is_float":true},"EXCESSGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW quantity of excess","examples":["0"],"is_float":true},"INITIALSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of initial generation and import for region","examples":["934.25336","8766.90198"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LORSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not in use after 17 Feb 2006. Total short term generation capacity reserve used in assessing lack of reserve condition","is_float":true},"LOWER1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Lower1Sec availability (summated from UnitSolution)","examples":["232.90117","0","74","1191"],"is_float":true},"LOWER1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Lower1Sec Dispatched in Region - RegionSolution element L1Dispatch attribute","examples":["0.25","0","1","62"],"is_float":true},"LOWER5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 5min availability","examples":["24.04","108","1363.29446","1403"],"is_float":true},"LOWER5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min local dispatch","examples":["5.87","0","1","223"],"is_float":true},"LOWER6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 6sec availability","examples":["18.8","71","1393.53295","1465"],"is_float":true},"LOWER6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec local dispatch","examples":["5.87","0","1","218"],"is_float":true},"LOWER60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 60sec availability","examples":["28.665217","72","1585.76048","1508"],"is_float":true},"LOWER60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec local dispatch","examples":["5.87","0","1","250"],"is_float":true},"LOWERREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower reg availability","examples":["39.116356","40","2398.9741","1287"],"is_float":true},"LOWERREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation local dispatch","examples":["4.22","0","1","150"],"is_float":true},"LRCSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not in use after 17 Feb 2006. Total short term generation capacity reserve above the stated low reserve condition requirement","is_float":true},"NETINTERCHANGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the regional reference node","examples":["-8.77","0.97","0","-592"],"is_float":true},"RAISE1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Raise1Sec availability (summated from UnitSolution)","examples":["326.2","18","1026.76153","1229"],"is_float":true},"RAISE1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Raise1Sec Dispatched in Region - RegionSolution element R1Dispatch attribute","examples":["1.64","0","3","202"],"is_float":true},"RAISE5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 5min availability","examples":["52.550757","244","1211.84587","1494"],"is_float":true},"RAISE5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min local dispatch","examples":["11.58","0","2","293"],"is_float":true},"RAISE6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 6sec availability","examples":["148.63782","163","1380.73636","1449"],"is_float":true},"RAISE6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec local dispatch","examples":["0.18","0","2","242"],"is_float":true},"RAISE60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 60sec availability","examples":["128.888833","176","1485.73636","1555"],"is_float":true},"RAISE60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec local dispatch","examples":["0.18","0","12","261"],"is_float":true},"RAISEREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise reg availability","examples":["23.91481","10","2662.969009","2266"],"is_float":true},"RAISEREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation local dispatch","examples":["0.24","0","1","170"],"is_float":true},"SEMISCHEDULE_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW","examples":["105.77901","4665.24012"],"is_float":true},"SEMISCHEDULE_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced","examples":["12.4356","0","26","559"],"is_float":true},"SS_SOLAR_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Solar units in that region","examples":["0.098","0","4312.51767"],"is_float":true},"SS_SOLAR_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is solar","examples":["0.098","0","6","10"],"is_float":true},"SS_SOLAR_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is solar","examples":["0.001","0","2","331"],"is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is solar","examples":["0.098","0","4312.51767"],"is_float":true},"SS_WIND_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Wind units in that region","examples":["105.77901","4352.08244"],"is_float":true},"SS_WIND_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is wind","examples":["88.403","3868.0216"],"is_float":true},"SS_WIND_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is wind","examples":["7.40743","0","4","559"],"is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is wind","examples":["105.77901","4361.05926"],"is_float":true},"TOTALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand (less loads)","examples":["751.94","940","8589.01","7200"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["21.92","0","395.10674"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["105.77901","5753.95002"],"is_float":true},"WDR_AVAILABLE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated available MW for Wholesale Demand Response (WDR) units","examples":["0","1"],"is_float":true},"WDR_DISPATCHED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated dispatched MW for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"WDR_INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated MW value at start of interval for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"LOWER5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW dispatch","unused":true,"is_float":true},"LOWER5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW imported","unused":true,"is_float":true},"LOWER5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 5 min","unused":true,"is_float":true},"LOWER5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 5 min","unused":true,"is_float":true},"LOWER5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min total requirement","unused":true,"is_float":true},"LOWER5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 5 min","unused":true,"is_float":true},"LOWER5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min requirement","unused":true,"is_float":true},"LOWER6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW dispatch","unused":true,"is_float":true},"LOWER6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW imported","unused":true,"is_float":true},"LOWER6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec total requirement","unused":true,"is_float":true},"LOWER6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 seconds requirement","unused":true,"is_float":true},"LOWER60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW dispatch","unused":true,"is_float":true},"LOWER60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW imported","unused":true,"is_float":true},"LOWER60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec total requirement","unused":true,"is_float":true},"LOWER60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 seconds requirement","unused":true,"is_float":true},"LOWERREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation MW imported","unused":true,"is_float":true},"LOWERREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation local requirement","unused":true,"is_float":true},"LOWERREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg local requirement","unused":true,"is_float":true},"LOWERREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation total requirement","unused":true,"is_float":true},"LOWERREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg requirement","unused":true,"is_float":true},"RAISE5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW dispatch","unused":true,"is_float":true},"RAISE5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW imported","unused":true,"is_float":true},"RAISE5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise price of lower 5 min","unused":true,"is_float":true},"RAISE5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 5 min","unused":true,"is_float":true},"RAISE5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min total requirement","unused":true,"is_float":true},"RAISE5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 5 min","unused":true,"is_float":true},"RAISE5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min requirement","unused":true,"is_float":true},"RAISE6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW dispatch","unused":true,"is_float":true},"RAISE6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW imported","unused":true,"is_float":true},"RAISE6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec total requirement","unused":true,"is_float":true},"RAISE6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 seconds requirement","unused":true,"is_float":true},"RAISE60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW dispatch","unused":true,"is_float":true},"RAISE60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW imported","unused":true,"is_float":true},"RAISE60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec total requirement","unused":true,"is_float":true},"RAISE60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 seconds requirement","unused":true,"is_float":true},"RAISEREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation MW imported","unused":true,"is_float":true},"RAISEREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation local requirement","unused":true,"is_float":true},"RAISEREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg local requirement","unused":true,"is_float":true},"RAISEREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation total requirement","unused":true,"is_float":true},"RAISEREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg requirement","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCHREGIONSUM%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":6389946,"decompressed_size_all_time":7019113840},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes","pagination":["Elec22_1.htm","Elec22_2.htm"]},"DISPATCHTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#458"],"comment":"DISPATCHTRK is no longer used. DISPATCHTRK was the cross-reference between each dispatch run and SPD case run. DISPATCHTRK may be available on the InfoServer but not replicated to participant databases as it contains data duplicated in other tables.","description":"This is a public table, and is available to all participants.\n\nSource\n\nNo longer used; discontinued 30/09/2001","unused":true,"primary_keys":["RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no, normally 1.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date and time starting at 04:05","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REASON":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Reason code (if rerun)"},"SPDRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Case identifier for LP Solver","is_integer":true,"num_int_bits":16}},"visibility":"Public"},"DISPATCH_AGC_DATA":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"AGC_DATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#10"],"comment":"THIS report delivers 4-second system data from the AEMO AGC system","primary_keys":["AGC_AREA","AGC_DATA_TYPE","MEASUREMENT_DATETIME","VERSIONNO"],"columns":{"AGC_AREA":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"AGC Control Region"},"AGC_DATA_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"AGC parameter type"},"MEASUREMENT_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the SCADA data(DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone(NEM time)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Count of version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGC_VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"AGC parameter value","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Every 5 minutes"},"DISPATCH_CONSTRAINT_FCAS_OCD":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCHOCD","REPORT_SUB_TYPE":"CONSTRAINT_FCAS_OCD","VERSION":1},{"REPORT_NAME":"PRICELOAD","REPORT_SUB_TYPE":"CONSTRAINT_FCAS_OCD","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#16"],"comment":"FCAS constraint solution from OCD re-run.","primary_keys":["CONSTRAINTID","INTERVENTION","RUNNO","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"ConstraintID/GenconID","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_TL_L1_DS","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+ML_L5_APD","F_I+ML_L60_APD","F_I+ML_L6_APD","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++ML_L5_APD","F_MAIN++ML_L60_APD","F_MAIN++ML_L6_APD","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+ML_L5_APD","F_MAIN+ML_L60_APD","F_MAIN+ML_L6_APD","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_TL_L5_DS","F_T+NIL_TL_L60_DS","F_T+NIL_TL_L6_DS","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"],"is_categorical":true},"INTERVENTION":{"sql_type":"NUMBER(2)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention 0/1","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch interval that the prices were loaded to","examples":["2026/08/05 16:25:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"VersionNo","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2026/08/05 16:20:14"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"marginalvalue from OCD re-run","examples":["0.01","0","19.92"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RHS from OCD re-run","examples":["-0.0001","10.03286","0","1390"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The violation degree of this constraint in the solution result","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_08/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_CONSTRAINT_FCAS_OCD%23FILE01%23202608010000.zip","manifest_summary":{"first_month":{"year":2024,"month":10},"last_month":{"year":2026,"month":8},"has_missing_months":true,"compressed_size_per_month":3779,"decompressed_size_all_time":221500},"visibility":"Public"},"DISPATCH_FCAS_REQ":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"FCAS_REQ","VERSION":2,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#410"],"comment":"DISPATCH_FCAS_REQ shows Dispatch Constraint tracking for Regional FCAS recovery.","description":"DISPATCH_FCAS_REQ is public data and is available to all participants.\n\nSource\n\nDISPATCH_FCAS_REQ updates with each dispatch run (5 minutes).\n\nVolume\n\nApproximately 10,000 rows per day","unused":true,"primary_keys":["BIDTYPE","GENCONID","INTERVENTION","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Constraint ID - Join to table GenConData","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_MG_RECL_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_TL_L1_DS","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LREG_0210","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LREG_0210","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_MG_RECL_R5","F_T++NIL_MG_RECL_R6","F_T++NIL_MG_RECL_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R6","F_T++NIL_WF_TG_R60","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_MG_RECL_R5","F_T+NIL_MG_RECL_R6","F_T+NIL_MG_RECL_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_TL_L5_DS","F_T+NIL_TL_L60_DS","F_T+NIL_TL_L6_DS","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R6","F_T+NIL_WF_TG_R60","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention Flag","examples":["0"],"is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date and time of Dispatch Interval","examples":["2025/05/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, before the regulation/contingency split","examples":["0.04272329","0","81.45833333"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint for this service, before the regulation/contingency split","examples":["0.04272329","0","81.45833333"],"is_float":true},"ESTIMATED_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CMPF, based on dispatched data","examples":["4.81533","0","64.8178"],"is_float":true},"ESTIMATED_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CRMPF, based on dispatched data","examples":["1.81947056","0","35.18220213"],"is_float":true},"GENCONEFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Generic Constraint EffectiveDate - Join to table GenConData","examples":["2013/08/21 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Generic Constraint Version number - Join to table GenConData","examples":["1"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record is changed","examples":["2025/05/01 00:00:03"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"examples":["0.01","0","5.99"],"is_float":true},"RECOVERY_FACTOR_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery factor for CMPF based recovery","examples":["0.01504032","0","3.75545074"],"is_float":true},"RECOVERY_FACTOR_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery factor for CRMPF based recovery","examples":["0.00002538","0","0.00633735"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2025/MMSDM_2025_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_FCAS_REQ%23FILE01%23202505010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2025,"month":5},"has_missing_months":true,"compressed_size_per_month":23552937,"decompressed_size_all_time":37470314790},"visibility":"Public","trigger":"Each dispatch run (5 minutes)"},"DISPATCH_FCAS_REQ_CONSTRAINT":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"FCAS_REQ_CONSTRAINT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#24"],"comment":"The constraint level FCAS cost / price details for constraint FCAS processor runs. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["BIDTYPE","CONSTRAINTID","INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNNO"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"ConstraintID join to table GenConData","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_TL_L1_DS","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_TL_L5_DS","F_T+NIL_TL_L60_DS","F_T+NIL_TL_L6_DS","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The trading interval date and time of the dispatch interval that was processed by the constraint FCAS processor","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the dispatch case that triggers the constraint FCAS processor run","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The dispatch case run number that has triggers the constraint FCAS processor run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, after the regulation/contingency split","examples":["0.31531698","0","48.875"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint, before the regulation/contingency split","examples":["0.31531698","0","48.875"],"is_float":true},"CONSTRAINT_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW enabled for this bid type within the constraint","examples":["26.25994","0","45","220"],"is_float":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints summed LHS - aggregate LHS Solution values from the physical run from the DISPATCHCONSTRAINT table","examples":["-26.87783","26.25994","0","220"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Shadow price of constraint from the DISPATCHCONSTRAINT table from the physical run.","examples":["0.01","0","5.38"],"is_float":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted marginal value of the constraint for FPP recovery (blank for constraints without REG terms)","examples":["0.01","0","5.38"],"is_float":true},"REGION_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The regional payment allocated to the constraint for the interval pro-rated based on marginal value ratios over the binding constraints for that service in that region (this is an intermediate calculation to get to the base cost)","examples":["0.00333333","0","35.3625"],"is_float":true},"REGIONAL_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The dispatched MW for the bid type inside the region from the physical run of the DISPATCHREGIONSUM table","examples":["22.25994","0","4","252"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints RHS value used in the solution - may be either dynamic (calculated) or static from the physical run from the DISPATCHCONSTRAINT table","examples":["-0.0001","19.75664","0","1390"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Bid type prices for the region coming from the pricing run of the DISPATCHREGIONSUM table","examples":["0.01","0","1","5.39"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_FCAS_REQ_CONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":3,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":63414350,"decompressed_size_all_time":124112138560},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a dispatch run"},"DISPATCH_FCAS_REQ_RUN":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"FCAS_REQ_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#30"],"comment":"The constraint FCAS processor run details. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["RUN_DATETIME","RUNNO"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the dispatch case that triggers the constraint FCAS processor run","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The dispatch case run number that has triggers the constraint FCAS processor run","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last time the constraint FCAS processor was executed for this case run time.","examples":["2026/09/01 00:00:15"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_FCAS_REQ_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":48633,"decompressed_size_all_time":121864560},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a dispatch run"},"DISPATCH_INTERCONNECTION":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"INTERCONNECTION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#36"],"comment":"Inter-regional flow information common to or aggregated for regulated (i.e. not MNSP) Interconnectors spanning the From-Region and To-Region - NB only the physical run is calculated'","primary_keys":["FROM_REGIONID","INTERVENTION","RUNNO","SETTLEMENTDATE","TO_REGIONID"],"columns":{"FROM_REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Nominated RegionID from which the energy flows","examples":["NSW1","TAS1","VIC1"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Intervention case or not","examples":["0"],"is_boolean":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TO_REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated RegionID to which the energy flows","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"DISPATCHINTERVAL":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Dispatch period identifier, from 001 to 288 in format YYYYMMDDPPP","examples":["20260831241","20260901202"],"is_integer":true,"num_int_bits":128},"FROM_REGION_MW_LOSSES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Losses across the Interconnection attributable to the nominal From Region","examples":["-0.007522","0.006059","0","74.27363"],"is_float":true},"IRLF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Inter-Regional Loss Factor. Calculated based on the MWFLOW and the nominal From and To Region losses.","examples":["0.66667","0","1.5"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"METEREDMWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Summed Metered MW flow of the parallel regulated Interconnectors","examples":["-3.300049","5.999847","0","224"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Summed MW flow of the parallel regulated Interconnectors","examples":["-0.59655","2.68798","0","162"],"is_float":true},"TO_REGION_MW_LOSSES":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Losses across the Interconnection attributable to the nominal To Region","examples":["-0.004418","0.004544","0","83.457116"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_INTERCONNECTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1054799,"decompressed_size_all_time":229130890},"visibility":"Public","trigger":"Every 5 minutes"},"DISPATCH_LOCAL_PRICE":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"LOCAL_PRICE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#42"],"comment":"Sets out local pricing offsets associated with each DUID connection point for each dispatch period. Note that from 2014 Mid year release only records with non-zero Local_Price_Adjustment values are issued","primary_keys":["DUID","SETTLEMENTDATE"],"indexes":[["SETTLEMENTDATE","DUID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["AGLHAL","ARWF1","BALB1","BALDHWF1","BANN1","BHB1","BLUFF1","BOMENSF1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","CHYTWF1","CNUNDAWF","COHUNSF1","COLEASF1","CROWLWF1","CRWASF1","DARLSF1","DARTM1","DUNDWF1","DUNDWF2","DUNDWF3","EILDON1","EILDON2","ELAINWF1","FINLYSF1","GANNB1","GANNSF1","GIRGSF","GLENSF1","GLRWNSF1","GSWF1A","GSWF1B1","GUTHEGA","HALLWF1","HALLWF2","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HILLSTN1","HPR1","HUMENSW","HUMEV","JEMALNG1","JUNEESF1","KARSF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","LADBROK1","LADBROK2","LANCSF1","LBB1","LIMOSF11","LIMOSF21","LKBONNY1","LKBONNY2","LKBONNY3","MACARTH1","MCKAY1","MERCER01","MOKOSF1","MOORAWF1","MRNBESS1","MRTLSWF1","MTGELWF1","MURRAY","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NUMURSF1","OAKLAND1","PIBESS1","RANGEB1","RYANCWF1","SALTCRK1","SEBSF1","SNOWTWN1","SNOWYP","SNUG1","STWF1","SUNRSF1","TRGBESS1","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","WAGGNSF1","WEMENSF1","WGWF1","WINTSF1","WKIEWA1","WPWF","WSTWYSF1","WUNUSF1","WYASF1","YATSF1","YENDWF1","YWPS2","YWPS3","YWPS4","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date time starting at 04:05","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this unit: Sum(MarginalValue x Factor) for all relevant Constraints","examples":["-1.97","1.63","-1010.5","51.66"],"is_float":true},"LOCALLY_CONSTRAINED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["1","2"],"is_integer":true,"num_int_bits":8}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_LOCAL_PRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3059006,"decompressed_size_all_time":515283670},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes"},"DISPATCH_MNSPBIDTRK":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"MNSPBIDTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#50"],"comment":"DISPATCH_MNSPBIDTRK shows the MNSP bid tracking, including the bid version used in each dispatch run for each MNSP Interconnector Link. The table identifies which bids from MNSP_DAYOFFER and MNSP_BIDOFFERPERIOD were applied.","description":"DISPATCH_MNSPBIDTRK shows own details for participant as they occur,\nwith all details until close of business yesterday being available to\nall participants after end of day.\n\nSource\n\nDISPATCH_MNSPBIDTRK potentially updates every 5 minutes.\n\nVolume\n\n220, 000 per year","primary_keys":["LINKID","PARTICIPANTID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"LINKID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS","BLNKVIC"]},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant that owns unit during effective record period","examples":["BASSLINK"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:05","examples":["2026/06/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Record creation timestamp","examples":["2026/06/01 00:00:03"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFEREFFECTIVEDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Time this bid was processed and loaded","examples":["2026/05/31 23:56:05.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"OFFERSETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Offer date for bid","examples":["2026/05/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"VersionNo of the bid/offer used","examples":["1"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_06/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_MNSPBIDTRK%23FILE01%23202606010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":6},"compressed_size_per_month":127219,"decompressed_size_all_time":126464660},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes"},"DISPATCH_MR_SCHEDULE_TRK":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"MR_SCHEDULE_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#59"],"comment":"DISPATCH_MR_SCHEDULE_TRK records the Mandatory Restrictions Acceptance Schedule applied to this dispatch interval for this region.\nDISPATCH_MR_SCHEDULE_TRK is populated by the Dispatch process and records the MR Offer Stack applied in each dispatch interval. DISPATCH_MR_SCHEDULE_TRK is used by Settlements to calculate payments according to the correct MR offer stack.","description":"DISPATCH_MR_SCHEDULE_TRK data is public to all participants.\n\nSource\n\nDISPATCH_MR_SCHEDULE_TRK updates are ad hoc.\n\nVolume\n\n2 rows per year.","primary_keys":["REGIONID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID; Key reference to MR_Event_Schedule","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time of the Dispatch Interval","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was last inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Mandatory Restriction date; Key reference to MR_Event_Schedule table","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time the MR acceptance stack was created; Key reference to MR_Event_Schedule table","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Ad hoc"},"DISPATCH_PRICE_REVISION":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PRICELOAD","REPORT_SUB_TYPE":"PRICE_REVISION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#68"],"comment":"An audit trail of price changes on the DISPATCHPRICE table (i.e. for 5 minute dispatch prices for energy and FCAS).","primary_keys":["BIDTYPE","INTERVENTION","REGIONID","RUNNO","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Affected Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Manual intervention flag; always 0","examples":["0"],"is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Affected Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date and time starting at 04:05","examples":["2026/03/23 11:45:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of price revision for this settlement date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Enum([\"1\"])","mandatory":true,"comment":"Dispatch run no; always 1","examples":null,"unused":true,"enums":[1],"unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime the record was last changed","examples":["2026/03/24 12:27:37"],"parse_csv_as_string":true,"is_s_datetime":true},"RRP_NEW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"New RRP in DISPATCHPRICE table","examples":["0.02","44.02"],"is_float":true},"RRP_OLD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Old RRP from DISPATCHPRICE table","examples":["0.01","0","6.98"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_03/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_PRICE_REVISION%23FILE01%23202603010000.zip","manifest_summary":{"first_month":{"year":2015,"month":2},"last_month":{"year":2026,"month":3},"has_missing_months":true,"compressed_size_per_month":551,"decompressed_size_all_time":1876070},"visibility":"Public","trigger":"Every 5 minutes"},"DISPATCH_ROOFTOP_PV_FCST_TRK":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#76"],"comment":"Uniquely tracks which Rooftop PV forecast run (from ROOFTOP_PV_FCST_P5_RUN) was used for the Area in which Dispatch run.","primary_keys":["AREAID","RUN_DATETIME"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Area identifier aligning with the load forecasting areas, tracks to ROOFTOP_PV_FCST_P5_RUN.AREAID."},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) of the Dispatch run.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Priority of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.FORECAST_PRIORITY.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime, unless a forecast run is missed, in this case the previous run is used. Tracks to ROOFTOP_PV_FCST_P5_RUN.FORECAST_RUN_DATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Submission datetime of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.OFFERDATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Provider identifier of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.PROVIDERID.","is_categorical":true}},"visibility":"Public","trigger":"Every 5 minutes when a new dispatch run is published"},"DISPATCH_UNIT_CONFORMANCE":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"UNIT_CONFORMANCE","VERSION":1},{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"UNIT_CONFORMANCE","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#82"],"comment":"DISPATCH_UNIT_CONFORMANCE details the conformance of a scheduled units operation with respect to a cleared target on dispatch interval basis.\nData is confidential","description":"DISPATCH_UNIT_CONFORMANCE data is confidential.\n\nSource\n\nDISPATCH_UNIT_CONFORMANCE shows data for every 5 minutes for all\nscheduled units\n\nVolume\n\nRows per day: 288 per scheduled unit","primary_keys":["DUID","INTERVAL_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier, or Aggregate Dispatch Group identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch Interval that the conformance data applies to","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACTUALMW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Unit output measured at the conclusion of the dispatch interval - MW (MWB)","is_float":true},"ADG_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Aggregate Dispatch Group to which this dispatch unit belongs"},"AVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Offered unit capacity - MW (MWO)","is_float":true},"CONFORMANCE_MODE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"For an individual unit in an aggregate dispatch group (where DUID <> ADG_ID), Mode specific to that unit. 0 - no monitoring, 1 - aggregate monitoring, 2 - individual monitoring due to constraint. For the aggregate dispatch group (where DUID = ADG_ID), 0 - no aggregate monitoring, 1 - aggregate monitoring","is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LECOUNT":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Large trigger error count. Reset when mwerror changes sign","is_integer":true,"num_int_bits":32},"LOWERREG":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation FCAS enabled - MW (FCL)","is_float":true},"LTRIGLM":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated large trigger error limit in MW","is_float":true},"MAX_MWERROR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Max of mwerror while that unit was not in a normal state","is_float":true},"MWERROR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated actual error","is_float":true},"OPERATING_MODE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"conformance operating mode\nMANUAL\nAUTO"},"PARTICIPANT_STATUS_ACTION":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Participant action required in response to current STATUS"},"RAISEREG":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation FCAS enabled - MW (FCR)","is_float":true},"ROC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Rate of change in direction of error MW per minute","is_float":true},"SECOUNT":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Small trigger error count. Reset when mwerror changes sign","is_integer":true,"num_int_bits":32},"SEMIDISPATCHCAP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Boolean representation flagging if the Target is capped","is_boolean":true},"STATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unit conformance status.\nNORMAL\nOFF-TARGET\nNOT-RESPONDING\nNC-PENDING\nNON-CONFORMING\nSUSPENDED"},"STRIGLM":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated small trigger error limit in MW","is_float":true},"TOTALCLEARED":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatch Target - MW","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes"},"DISPATCH_UNIT_SCADA":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"UNIT_SCADA","VERSION":1}],"transaction_type":"INSERT-UPDATE"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.htm#91"],"comment":"Dispatchable unit MW from SCADA at the start of the dispatch interval. The table includes all scheduled and semi-scheduled (and non-scheduled units where SCADA is available)","description":"DISPATCH_UNIT_SCADA data is public data, and is available to all\nparticipants.\n\nSource\n\nDISPATCH_UNIT_SCADA shows data for every 5 minutes for all scheduled\nunits\n\nVolume\n\nRows per day: 288 per each scheduled, semi-scheduled (and non-scheduled\nunit where SCADA is available)","primary_keys":["DUID","SETTLEMENTDATE"],"indexes":[["SETTLEMENTDATE","DUID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","CONDONG1","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBG1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","PIONEER","PLBESS1","POAT110","POAT220","POR01","POR03","PORTWF","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUBICON","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHOAL1","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TULLYSM1","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time of the Dispatch Interval","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:13"],"parse_csv_as_string":true,"is_s_datetime":true},"SCADAVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Instantaneous MW reading from SCADA at the start of the Dispatch interval","examples":["-0.02","0.00001","0","531"],"warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DISPATCH_UNIT_SCADA%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":33055671,"decompressed_size_all_time":25645872480},"visibility":"Public","warnings":[{"msg":"Table DISPATCHLOAD is similar but contains even more detail (but is larger).","category":"related_tables","level":"tip"}],"trigger":"Every 5 minutes"},"DUALLOC":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DUALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#40"],"comment":"DUALLOC cross references dispatch unit identifier to genset ID for each participant.","description":"Source\n\nDUALLOC updates where changed.","primary_keys":["DUID","EFFECTIVEDATE","GENSETID","VERSIONNO"],"indexes":[["LASTCHANGED"],["DUID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["APD01","APD02","APS","BARCALDN","BARRON-1","BARRON-2","BAYNL1","BDL01","BHASZINC","BLOWER","BROWNMT","BURRIN","BW01","BW02","BW03","BW04","CALLNL1","CALLNL2","CALLNL3","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CLOVER1","CLOVER2","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","CPP_3","DARTM1","DLNKNSW","DLNKQLD","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL","DRYCNL3","EILDON1","EILDON2","ER01","ER02","ER03","ER04","ERG_AS","ERNL1","FARLEIGH","GB01","GB02","GLADNL1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUTH-1","GUTH-2","HUMENSW","HUMEV","HVGTS","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","JACKSGUL","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARYNL1","KEEPIT","KKGTS","LADBROK1","LADBROK2","LD01","LD02","LD03","LD04","LIDDNL1","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYA4","LYNL1","MACKAYGT","MACKNADE","MARIAN","MCKAY1","MCKAY2","MINTARO","MINTNL1","MM3","MM4","MMNL1","MOR1","MOR2","MOR3","MORNL1","MP1","MP2","MPNL1","MPP_1","MRIDGE","MSTUART1","MSTUART2","MULGRAVE","MURR1-1","MURR1-10","MURR1-2","MURR1-3","MURR1-4","MURR1-5","MURR1-6","MURR1-7","MURR1-8","MURR1-9","MURR2-1","MURR2-2","MURR2-3","MURR2-4","NGTS","NPS","NPS1","NPS2","NPSNL1","NPSNL2","OAKEY1","OAKEY2","OSB-AG","OSB01","OSB02","PLANECRK","PLAYB-AG","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PLEYSTOW","POR01","PPCCGT","PTH01","PTH02","PTH03","PUMP1","PUMP2","RCOURSE","REDBANK1","ROMA_7","ROMA_8","RUBICON","SHGEN","SHGEN2","SHPUMP","SITHE01","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUGNL1","SNWYGJP2","STAN-1","STAN-2","STAN-3","STAN-4","STANNL1","STHJST","SWANNL1","SWANNL2","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","TARNL1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TBLD","TOMAGO1","TOMAGO2","TOMAGO3","TORNL1","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TUMUT1-1","TUMUT1-2","TUMUT1-3","TUMUT1-4","TUMUT2-1","TUMUT2-2","TUMUT2-3","TUMUT2-4","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","UWS1","VICSMLT","VP5","VP6","VPNL1","W/HOE#1","W/HOE#2","WG01","WGULLY","WHILL1","WKIEWA1","WKIEWA2","WW7","WW8","WWNL1","YABULU","YWNL1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective calendar date of record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Physical unit identifier","examples":["APD01","APD02","APS","BARCALDN","BARRON-1","BARRON-2","BAYNL1","BDL01","BHASZINC","BLOWER","BROWNMT","BURRIN1","BURRIN2","BW01","BW02","BW03","BW04","CALLNL1","CALLNL2","CALLNL3","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CLOVER1","CLOVER2","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","CPP_3","DARTM1","DLNKNSW","DLNKQLD","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL1","DRYCNL2","DRYCNL3","EILDON1","EILDON2","ENERGYB1","ENERGYB2","ENERGYB3","ENERGYB4","ENERGYB5","ER01","ER02","ER03","ER04","ERG_AS","ERNL1","FARLEIGH","GB01","GB02","GE01","GE02","GE03","GE04","GH01","GH02","GK01","GK02","GK03","GK04","GLADNL1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUTH-1","GUTH-2","HUMENSW1","HUMEV1","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","JACKSGUL","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARYNL1","KEEPIT","LADBROK1","LADBROK2","LD01","LD02","LD03","LD04","LIDDNL1","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYA4","LYNL1","MACKAYGT","MACKNADE","MARIAN","MCKAY1","MCKAY2","MINTARO","MINTNL1","MM3","MM4","MMNL1","MORNL1","MP1","MP2","MPNL1","MPP_1","MRIDGE","MSTUART1","MSTUART2","MULGRAVE","MURR1-1","MURR1-10","MURR1-2","MURR1-3","MURR1-4","MURR1-5","MURR1-6","MURR1-7","MURR1-8","MURR1-9","MURR2-1","MURR2-2","MURR2-3","MURR2-4","NPS","NPS1","NPS2","NPSNL1","NPSNL2","OAKEY1","OAKEY2","OSB01","OSB02","PLANECRK","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PLEYSTOW","POR01","PPGT11","PPGT12","PPST18","PTH01","PTH02","PTH03","PUMP1","PUMP2","RCOURSE","REDBANK1","ROMA_7","ROMA_8","RUBICON","SH01","SH02","SH03","SH04","SHGEN2","SHP01","SHP02","SHP03","SHP04","SITHE01","SITHE02","SITHE03","SITHE04","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUG5","SNUG6","SNUGNL1","SNWYGJP2","STAN-1","STAN-2","STAN-3","STAN-4","STANNL1","STHJST","SWANNL1","SWANNL2","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","TARNL1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TBLD","TOMAGO1","TOMAGO2","TOMAGO3","TORNL1","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TUMUT1-1","TUMUT1-2","TUMUT1-3","TUMUT1-4","TUMUT2-1","TUMUT2-2","TUMUT2-3","TUMUT2-4","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","UWS1","VICSMLT","VP5","VP6","VPNL1","W/HOE#1","W/HOE#2","WG01","WGULLY","WHILL1","WKIEWA1","WKIEWA2","WW7","WW8","WWNL1","YABULU","YWNL1","YWPS1","YWPS2","YWPS3","YWPS4"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record","examples":["1","45"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/10/28 12:05:33"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DUALLOC%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2020,"month":10},"last_month":{"year":2026,"month":9},"compressed_size_per_month":26141,"decompressed_size_all_time":16924900},"visibility":"Public","trigger":"When the  dispatch unit identifier to genset ID cross reference is changed"},"DUDETAIL":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DUDETAIL","VERSION":6},{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DUDETAIL","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#51"],"comment":"DUDETAIL sets out a records specific details for each unit including start type and whether normally on or off load. Much of this data is information only and is not used in dispatch or settlements.","description":"DUDETAIL is public data, and is available to all participants.\n\nSource\n\nDUDETAIL updates only when registration details change.\n\nNote\n\nTo find the current set of details for selected dispatchable units,\nquery the participant's local database as follows.\n\nSelect du.\\* from dudetail du\n\nwhere (du.EFFECTIVEDATE, du.VERSIONNO) =\n\n(\n\nselect effectivedate, max(versionno)\n\nfrom dudetail\n\nwhere EFFECTIVEDATE = (select max(effectivedate)\n\nfrom dudetail\n\nwhere EFFECTIVEDATE \\<= sysdate\n\nand duid = du.duid\n\nand authoriseddate is not null)\n\nand duid = du.duid\n\nand authoriseddate is not null\n\ngroup by effectivedate\n\n)\n\nand du.duid in ('UNIT1', 'UNIT2')\n\n;\n\nThe following notes apply to this SQL code:\n\n· This table is specific to dispatch units only.\n\n· If you wish to query details for a different date, substitute a date\nexpression for \"sysdate\" in the \"where EFFECTIVEDATE \\<= sysdate\"\nclause.\n\n· If you wish to list all the units, remove the line \"and du.duid in\n('UNIT1', 'UNIT2')\"\n\n· The DUDETAIL table does not indicate if a unit is active; this is done\nthrough ownership (STADUALLOC) by an active station owned by an active\nparticipant (STATIONOWNER )\n\n· If you wish to query Station details refer to STATION, STATIONOWNER\nand STADUALLOC.\n\n· If you wish to look at connection point loss factors, refer to\nTRANSMISSIONLOSSFACTOR.","primary_keys":["DUID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["APD01","APD02","APS","BARCALDN","BARRON-1","BARRON-2","BAYNL1","BDL01","BHASZINC","BLOWER","BLOWERNG","BROWNMT","BURRIN","BW01","BW02","BW03","BW04","CALLNL1","CALLNL2","CALLNL3","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CLOVER1","CLOVER2","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","CPP_4","DARTM1","DLNKNSW","DLNKQLD","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL","DRYCNL3","EILDON1","EILDON2","ER01","ER02","ER03","ER04","ERG_AS","ERNL1","FARLEIGH","GB01","GB02","GLADNL1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUTH-1","GUTH-2","GUTHEGA","HUMENSW","HUMEV","HVGTS","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS6","HWPS8","JACKSGUL","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARYNL1","KEEPIT","KKGTS","LADBROK1","LADBROK2","LD01","LD02","LD03","LD04","LIDDNL1","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYNL1","MACKAYGT","MACKNADE","MARIAN","MCKAY1","MCKAY2","MINTARO","MINTNL1","MM3","MM4","MMNL1","MOR1","MOR2","MOR3","MORNL1","MP1","MP2","MPNL1","MPP_1","MPP_2","MRIDGE","MSTUART1","MSTUART2","MULGRAVE","MURR1-1","MURR1-10","MURR1-2","MURR1-3","MURR1-4","MURR1-5","MURR1-6","MURR1-7","MURR1-8","MURR1-9","MURR2-1","MURR2-2","MURR2-3","MURR2-4","MURRAY","NGTS","NPS","NPS1","NPS2","NPSNL1","NPSNL2","OAKEY1","OAKEY2","OSB-AG","OSB01","OSB02","PINDARI","PLANECRK","PLAYB-AG","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PLEYSTOW","POR01","PPCCGT","PTH01","PTH02","PTH03","PUMP1","PUMP2","RCOURSE","REDBANK1","ROMA_7","ROMA_8","RPCG","RUBICON","SHGEN","SHGEN2","SHPUMP","SITHE01","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUGNL1","SNWYGJP2","STAN-1","STAN-2","STAN-3","STAN-4","STANNL1","STHJST","SWANNL1","SWANNL2","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","TARNL1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TBLD","TOMAGO1","TOMAGO2","TOMAGO3","TORNL1","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TUMUT1-1","TUMUT1-2","TUMUT1-3","TUMUT1-4","TUMUT2-1","TUMUT2-2","TUMUT2-3","TUMUT2-4","TUMUT3","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","UPPTUMUT","UWS1","VICSMLT","VP5","VP6","VPNL1","W/HOE#1","W/HOE#2","WG01","WGULLY","WHILL1","WKIEWA1","WKIEWA2","WW7","WW8","WWNL1","YABULU","YWNL1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective calendar date of record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"version of Dispatchable Unit details for this effective date","examples":["1","48"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADG_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Aggregate Dispatch Group to which this dispatch unit belongs"},"AGCCAPABILITY":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"AGC Capability flag","examples":["Y","N"],"parse_csv_as_string":true,"value_map":{"Y":1,"N":0},"is_boolean":true},"AGGREGATED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Identifies if a unit is aggregated. This flag was initially added in GENUNITS_UNIT table which is now deprecated with IESS release.","is_boolean":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["BATCH"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["1998/10/28 12:08:27"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Country wide - Unique id of a connection point","examples":["NBAY1","NBAY2","NBAY3","NBAY4","NBAYL","NBKG1","NBKG2","NBLW","NBLW1","NBLW8","NBRM","NBUK","NDT11","NEPS1","NEPS2","NEPS3","NEPS4","NEPSL","NGJP","NGJP2","NGLN1","NGUT","NGUT1","NGUT2","NGUT8","NHUM","NKLK","NKPT","NLD31","NLDP1","NLDP2","NLDP3","NLDP4","NLDPL","NLP11","NLS11","NLTS","NLTS1","NLTS3","NLTS31","NLTS32","NLTS33","NLTS35","NLTS36","NLTS5","NLTS8","NMNP3","NMNP4","NMNPL","NMPPL","NMRK1","NMTP1","NMTP2","NMUR","NMUR01","NMUR02","NMUR03","NMUR04","NMUR05","NMUR06","NMUR07","NMUR08","NMUR09","NMUR1","NMUR10","NMUR11","NMUR13","NMUR21","NMUR22","NMUR23","NMUR24","NMUR3","NMUR5","NMUR7","NMUR8","NMUR9","NNGT","NSHL","NSHL2","NSHP1","NSYW","NSYW1","NTMG","NTMG1","NTMG2","NTMG3","NUTS","NUTS1","NUTS11","NUTS12","NUTS13","NUTS21","NUTS22","NUTS23","NUTS24","NUTS3","NUTS5","NUTS7","NUTS8","NVPP5","NVPP6","NVPPL","NWGB","NWW27","NWW28","NWWPL","QALC","QBCG","QBCK1","QBCK2","QBGH1","QBGH2","QBMH1","QCAA1","QCAA2","QCAA3","QCAA4","QCAB1","QCAB2","QCAC3","QCAC4","QCAX","QCLX","QCRN","QCVL1","QCVL2","QCVL3","QCVL4","QCVL5","QGLA","QGLD1","QGLD2","QGLD3","QGLD4","QGLD5","QGLD6","QGLL","QINF1","QING","QKAH1","QKAH2","QKAH3","QKAH4","QKRX","QKYH5","QMGT1","QMKA","QMKA1","QMKA2","QMKG","QMRP","QMSP1","QMSP2","QOKY1","QOKY2","QPIV","QRMA7","QRMA8","QSTN1","QSTN2","QSTN3","QSTN4","QSTX","QSW1","QSWA1","QSWA2","QSWA3","QSWA4","QSWA5","QSWA6","QSWB1","QSWB2","QSWB3","QSWB4","QSWC","QSWD","QSWX","QTRL","QTRN1","QTRN2","QTRN3","QTRN4","QTUL","QTUL1","QTYP","QWIP1","QWIP2","QWIV1","QWIV2","SBUN","SDCA1","SDCA2","SDCA3","SKLB","SLCCL","SMPS","SNBN1","SNBN2","SNPA1","SNPA2","SPAAL","SPEW1","SPEW2","SPLN1","SPPT","SPSD1","SPSD2","SPSD3","SPSD4","SSGA1","SSGA2","SSGA3","SSGA4","SSNN","STSA1","STSA2","STSA3","STSA4","STSB1","STSB2","STSB3","STSB4","STSYL","SWAT","VAPD1","VAPD2","VAPS","VAPS1","VDPS","VEPS1","VEPS2","VHUM","VHWP1","VHWP2","VHWP3","VHWP6","VHWP8","VHWPL","VJLGA1","VJLGA2","VJLGA3","VJLGA4","VJLGB1","VJLGB2","VJLGB3","VLYP1","VLYP2","VLYP3","VLYP5","VLYP6","VLYPL","VMBT1","VMBT2","VMKP1","VMKP2","VMWP4","VMWP5","VMWT1","VMWT2","VMWTL","VNPS","VPTH1","VPTH2","VPTH3","VRUB","VWKP1","VWKP2","VYP21","VYP22","VYP23","VYP24","VYP2L"],"is_categorical":true},"DISPATCHSUBTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Additional information for DISPATCHTYPE. For DISPATCHTYPE = LOAD, subtype value is WDR for wholesale demand response units. For DISPATCHTYPE = LOAD, subtype value is NULL for Scheduled Loads. For DISPATCHTYPE = GENERATOR type, the subtype value is NULL."},"DISPATCHTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"GENERATOR\", \"LOAD\", \"BIDIRECTIONAL\"])","mandatory":false,"comment":"Identifies LOAD, GENERATOR or BIDIRECTIONAL.","examples":null,"enums":["GENERATOR","LOAD","BIDIRECTIONAL"]},"INTERMITTENTFLAG":{"sql_type":"VARCHAR(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Indicate whether a unit is intermittent (e.g. a wind farm)","examples":["Y","N"],"parse_csv_as_string":true,"value_map":{"Y":1,"N":0},"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2008/12/10 09:21:25"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MIN_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids on BDU Load component with explanation for energy imports (MW/min)","is_integer":true,"num_int_bits":32},"LOAD_MIN_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids on BDU Load component with explanation for energy imports (MW/min)","is_integer":true,"num_int_bits":32},"MAXCAPACITY":{"sql_type":"NUMBER(6,1)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Capacity as used for bid validation","examples":["13.55","1","137.5","3756"],"warnings":["AEMO's documentation says that this is an integer (`NUMBER(6,0)`). Actually, the values in the CSV have fractional components."],"is_float":true},"MAXRATEOFCHANGEDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum ramp down rate for Unit (Mw/min)","is_integer":true,"num_int_bits":32},"MAXRATEOFCHANGEDOWN_LOAD":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower Ramp rate applied to BDU Load component (MW/min)","is_integer":true,"num_int_bits":32},"MAXRATEOFCHANGEUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum ramp up rate for Unit (Mw/min)","is_integer":true,"num_int_bits":32},"MAXRATEOFCHANGEUP_LOAD":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise Ramp rate applied to BDU Load component (MW/min)","is_integer":true,"num_int_bits":32},"MAXSTORAGECAPACITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The rated storage capacity (MWh), information only","is_float":true},"MIN_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids with explanation for energy imports (all DUID types and BDU Generation side) (MW/min)","is_integer":true,"num_int_bits":32},"MIN_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids with explanation for energy imports (all DUID types and BDU Generation side) (MW/min)","is_integer":true,"num_int_bits":32},"MINCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum capacity only for load side of BDU, otherwise 0 (MW)","is_integer":true,"num_int_bits":32},"NORMALLYONFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"For a dispatchable load indicates that the load is normally on or off.","examples":["N","Y"]},"PHYSICALDETAILSFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Indicates that the physical details for this unit are to be recorded"},"REGISTEREDCAPACITY":{"sql_type":"NUMBER(6,1)","pl_type":"pl.Float64","mandatory":false,"comment":"Registered capacity for normal operations","examples":["13.55","1","137.5","3756"],"warnings":["AEMO's documentation says that this is an integer (`NUMBER(6,0)`). Actually, the values in the CSV have fractional components."],"is_float":true},"REGISTEREDMINCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Registered minimum capacity only for load side of BDU, otherwise 0 (MW)","is_integer":true,"num_int_bits":32},"SEMISCHEDULE_FLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Indicates if the DUID is a Semi-Scheduled Unit","examples":["N"]},"SPINNINGRESERVEFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Indicates spinning reserve capability","examples":["N","Y"]},"STARTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Identify unit as Fast or Slow","examples":["FAST","NOT DISPATCHED","SLOW"]},"STORAGEEXPORTEFFICIENCYFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The storage energy export conversion efficiency. Number from 0 to 1 where 1 is lossless. Calculated as (decrease in exported energy / decrease in stored energy)","is_float":true},"STORAGEIMPORTEFFICIENCYFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The storage energy import conversion efficiency. Number from 0 to 1 where 1 is lossless. Calculated as (increase in stored energy / increase in imported energy)","is_float":true},"VOLTLEVEL":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Voltage Level","examples":["11","500"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DUDETAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":80431,"decompressed_size_all_time":75138380},"visibility":"Public","trigger":"When registration details change"},"DUDETAILSUMMARY":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DUDETAILSUMMARY","VERSION":6},{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"DUDETAILSUMMARY","VERSION":7}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#60"],"comment":"DUDETAILSUMMARY sets out a single summary unit table so reducing the need for participants to use the various dispatchable unit detail and owner tables to establish generating unit specific details.","description":"DUDETAILSUMMARY is a public table, and is available to all participants.\n\nSource\n\nDUDETAILSUMMARY updates only when registration details change.","primary_keys":["DUID","START_DATE"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["DRXNDE01","DRXNDJ01","DRXNFF01","DRXNFS01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL","EASTCRK","EASTCRK2","EILDON2","EILDON3","ER01","ER02","ER03","ER04","ERGT01","ERG_AS","ERNL1","FARLEIGH","FISHER","FNWF1","FSWF1","GANNBL1","GANNSF1","GB01","GB02","GEORGTN1","GEORGTN2","GERMCRK","GIRGSF","GLADNL1","GLBWNHYD","GNNDHSF1","GORDON","GORDON1","GORDON2","GORDON3","GOVILLB1","GRANGEAV","GSTONE1","GSTONE2","GSTONE3","GSTONE4","HALLWF1","HALLWF2","HEPWIND1","HEZ","HEZ1","HLMSEW01","HUMENSW","HUMEV","HVGTS","HVWWBA1G","HVWWBA1L","HVWWPV1","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","JOUNAMA1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARYNL1","KEEPIT","KEPBL1","KIAMSF1","KINCUM1","KPP_1","KRCCOGEN","KSP1","LADBROK1","LADBROK2","LAVNORTH","LD01","LD02","LD03","LD04","LEMONTME","LEM_WIL","LK_ECHO","LNGS1","LNGS2","LONGFORD","LONSDALE","LOYYB1","LOYYB2","LRSF1","LUCAS2S2","LUCASHGT","LYA1","LYA2","LYA3","LYA4","MM3","MM4","MMNL1","MOR2","MOR3","MORANBAH","MRIDGE","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"START_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Start date for effective record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ADG_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Aggregate Dispatch Group. Group into which the DUID is aggregated for Conformance. Null if DUID not aggregated for Conformance","examples":["GANNBESS_ADG1"]},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Country wide - Unique id of a connection point","examples":["NBKG1","NBKG2","NCMA2","NEP35B","NEPS1","NEPS2","NEPS3","NEPS4","NEPSL","NFBS1J","NGF31K","NGNE1G","NHUM","NKPT","NKU31H","NLD31","NLDP1","NLDP2","NLDP3","NLDP4","NLP11","NMNP3","NMNP4","NMNPL","NMRK2G","NNEE1H","NSW21","NSW23L","NSYS1","NSYS2G","NTU21J","NVYD1","NWDENC03","NWDENC09","NWDENC10","NWDENC13","QBRA4K","QGLA","QGLD1","QGLD2","QGLD3","QGLD4","QGLL","QGNG1I","QINV1I","QKAH1","QKAH2","QKAH3","QKAH4","QKRX","QKYH5","QLIL2","QLLV2L","QMKA","QMRG1K","QMRL1M","QMRP","QMSP1","QMSP2","QMSP3M","QROG1K","QROW4K","SDCA1","SDCA2","SDCA3","SHPS2W","SHVA1H","SHVA2H","SHVA3H","SKLB","SMOK1H","SMVE1","SPEW1","SPEW2","SWDENC01","SWDENC02","TFI11","TGO11","TGO17","TGO18","TGO19","TGO21","TGT31G","TGT32G","TJB11","TLE11","TSH11","TSH19","VAT21","VAT21L","VAT22L","VBAT2L","VEPS2","VER21H","VHUM","VHWP1","VHWP2","VHWP3","VHWP4","VHWP5","VHWP6","VHWP7","VHWP8","VHWPL","VJLGA1","VJLGA2","VJLGA3","VJLGA4","VJLGB1","VJLGB2","VJLGB3","VKGB2G","VKGS1G","VKMT1K","VLYP1","VLYP2","VLYP3","VLYP4","VLYP5","VLYP6","VMWP4","VMWP5","VMWT6","VSHS2G","VTG21M","VTGT6F","VTGT7F","VTT22E","VWDENC01","VWDENC02","VWDENC03","VWDENC04","VWDENC05","VWDENC06","VWDENC08","VWDENC09"],"is_categorical":true},"DISPATCHSUBTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Additional information for DISPATCHTYPE. For DISPATCHTYPE = LOAD, subtype value is WDR for wholesale demand response units For DISPATCHTYPE = LOAD, subtype value is NULL for Scheduled Loads. For DISPATCHTYPE = GENERATOR type, subtype value is NULL.","examples":["WDR"]},"DISPATCHTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"GENERATOR\", \"LOAD\", \"BIDIRECTIONAL\"])","mandatory":false,"comment":"Identifies LOAD, GENERATOR or BIDIRECTIONAL. This will likely expand to more generic models as new technology types are integrated into the NEM","examples":null,"enums":["GENERATOR","LOAD","BIDIRECTIONAL"]},"DISTRIBUTIONLOSSFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The distribution loss factor to the currently assigned connection point","examples":["0.8742","1","1.0572"],"is_float":true},"END_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"End date for effective record","examples":["1998/11/29 00:00:00"],"parse_csv_as_string":true,"is_date":true},"IS_AGGREGATED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Whether the DUID is classified as an \"Aggregated Unit\" under the rules. This impacts the Minimum Ramp Rate calculation","examples":["0","1"],"is_integer":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/10/07 16:50:26"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MAX_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"BDU only. MW/Min. Registered Maximum Ramp Rate Down value accepted for Energy Offers or Bids for energy imports","is_integer":true,"num_int_bits":32},"LOAD_MAX_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"BDU only. MW/Min. Registered Maximum Ramp Rate Up value accepted for Energy Offers or Bids for energy imports","is_integer":true,"num_int_bits":32},"LOAD_MAXIMUM_ENERGY_PRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only. Capped Offer/Bid Energy Price adjusted for TLF, DLF and VoLL for energy imports","is_float":true},"LOAD_MIN_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"BDU only. MW/Min. Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids with explanation for energy imports","is_integer":true,"num_int_bits":32},"LOAD_MIN_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"BDU only. MW/Min. Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids with explanation for energy imports","is_integer":true,"num_int_bits":32},"LOAD_MINIMUM_ENERGY_PRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only. Floored Offer/Bid Energy Price adjusted for TLF, DLF and MPF for energy imports","is_float":true},"MAX_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum ramp down rate for Unit (Mw/min) - from DUDetail table","examples":["0","1","1000"],"is_integer":true,"num_int_bits":32},"MAX_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum ramp up rate for Unit (Mw/min) - from DUDetail table","examples":["0","1","1000"],"is_integer":true,"num_int_bits":32},"MAXIMUM_ENERGY_PRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capped Offer/Bid Energy Price adjusted for TLF, DLF and VoLL","examples":["4576.5","4711","20346.69","20300"],"is_float":true},"MIN_RAMP_RATE_DOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min. Calculated Minimum Ramp Rate Down value accepted for Energy Offers or Bids with explanation","examples":["0","1","150"],"is_integer":true,"num_int_bits":32},"MIN_RAMP_RATE_UP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min. Calculated Minimum Ramp Rate Up value accepted for Energy Offers or Bids with explanation","examples":["0","1","150"],"is_integer":true,"num_int_bits":32},"MINIMUM_ENERGY_PRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Floored Offer/Bid Energy Price adjusted for TLF, DLF and MPF","examples":["-835.27","-895","-1202.4","-1140"],"is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant that owns unit during effective record period","examples":["AGLAM","AGLSHYDR","BORAL","CNRGY","CSENERGY","DELTA","DIAMDGEN","DIAMOND","ECOGEN","EDISON","EDLCSMQ","EDLGRPOP","EDLLFGN","EEUS","ENELAUS","ENERBRIX","ENOCMASP","ERGON","ESNRGY","FERGUSWF","GANNBESS","GANNSF","GUNNEDAH","HAZELPWR","HEPBURN","HYDROTAS","INFRATIL","KENNEDYE","KSFPROJT","LMSGEN","LONSDALE","LOYYANGA","MACQGEN","MORTLSWF","NORPOWER","OERARING","PACHYDIN","PACPOWER","PEAKCO","PROGREEN","QTPTC","SAWCML","SNOWY","SOUTHHYD","SOUTHYD2","STANRET","STANWELL","TIPSCO","YESSA"],"is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier that unit is in","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCHEDULE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Scheduled status of the unit:\n'SCHEDULED'\n'NON-SCHEDULED'\n'SEMI-SCHEDULED'","examples":["NON-SCHEDULED","SCHEDULED","SEMI-SCHEDULED"]},"SECONDARY_TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Used in Bidding, Dispatch and Settlements, only populated where Dual TLFs apply. For Bidding and Dispatch, the TLF for the generation component of a BDU, when null the TRANSMISSIONLOSSFACTOR is used for both the load and generation components. For Settlements, the secondary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is positive (net generation).","is_float":true},"STARTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unit start type. At this time restricted to Fast, Slow or Non Dispatched","examples":["FAST","NOT DISPATCHED","SLOW"]},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Station that unit is in","examples":["BHILLGT","DRXNDE01","DRXNDJ01","DRXNFF01","DRXNFS01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT","EASTCRK","EASTCRK2","EILDON","EILDONPD","ENERGYB","ERARING","ERGT01","ERG_AS","FARLEIGH","FISHER","FNWF","FSWF","G/STONE","GANNBESS","GANNSF","GEORGTWN","GERMCRK","GIRGSF","GLBWNHYD","GNNDHSF","GORDON","GRANGEAV","HALLWF","HALLWF2","HAZEL","HEPWIND","HEZ","HEZ1","HLMSEW01","HUMENSW","HUMEV","HUNTVGT","HVWW","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEERA","JEERB","JEMALNG","JNDSHPS","JOUNAMA","KAREEYA","KEEPIT","KEP","KIAMSF","KINCUMB","KOGANCK","KRCCOGEN","KSP1","LADBROKE","LEM_WIL","LIDDELL","LK_ECHO","LNGS","LONGFORD","LONSDALE","LOYYANGA","LOYYB","LRSF","LUCAS2S2","LUCASHGT","MM","MORANBAH","MRTLSWF","MSTUART","SWANBANK"],"is_categorical":true},"TRANSMISSIONLOSSFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Used in Bidding, Dispatch and Settlements. For Bidding and Dispatch, where the DUID is a BDU with DISPATCHTYPE of BIDIRECTIONAL, the TLF for the load component of the BDU. For Settlements, where dual TLFs apply, the primary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is negative (net load).","examples":["0.8775","1","1.2024"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23DUDETAILSUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":379434,"decompressed_size_all_time":241238030},"visibility":"Public","trigger":"When registration details change"},"EMSMASTER":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENERIC_CONSTRAINT","REPORT_SUB_TYPE":"EMSMASTER","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#1"],"comment":"EMSMASTER provides a description of the SCADA measurements that are associated with the SPD_ID points utilised in generic equation RHS terms","primary_keys":["SPD_ID","SPD_TYPE"],"indexes":[["LASTCHANGED"]],"columns":{"SPD_ID":{"sql_type":"VARCHAR(21)","pl_type":"str","mandatory":true,"comment":"ID defining data source","examples":["AGLHAL.SHPS1","AGLSOM.VTTS1","ANGAS2.SDRN2","APD01.VAPD1","APD02.VAPD2","APDLOAD","APDLOAD_MVAR","ARMIDALE_CAP1_STATUS","ARMIDALE_SVC_ONSTATUS","ARTX_SUM_LOAD","BARCALDN.QBCG","BARCALDN_LOW_MW","BARCALDN_ROCDN_MWPM","BARRON-2.QBGH2","BARRON-2_LOW_MW","BAYSW_SUMM_INERT","BELLBAY1.TBBA1","BELLBAY2.TBBB1","BLGC_CAP6_STATUS","BL_FREQ_ONSTATUS","BL_PREVDI_TARGET","BL_TAS50HZ_ONSTATUS","BRAEMAR1.QBRA1","BRAEMAR2.QBRA2","BRKNHIL.GT1","BURRIN.NBUK","BUTLERSG.TBG11","BW01_HIGH_MW","BW01_OFFER_MW","BW02.NBAY2","BW02_OFFER_MW","BW03_OFFER_MW","BW04_HIGH_MW","BW04_ROCUP_MWPM","CALL_A_1.QCAA1","CALL_A_2_LOW_MW","CALL_A_2_ROCDN_MWPM","CALL_A_3.QCAA3","CALL_A_4.QCAA4","CALL_A_4_LOW_MW","CALL_B_1_ROCDN_MWPM","CALL_B_2.QCAB2","CALL_B_2_LOW_MW","CANUNDA_MW","CAPRAL_LOAD_2","CATA_1.TLI18","CATA_2.TLI19","CATHROCK.SCRK","CATHROCK_MW","CHAPEL_CAP1_STATUS","CHIMERA_HGUT","CHIMERA_HLTS","CHIMERA_HMUR","CHIMERA_HN","CHIMERA_HUTS","CHIMERA_HV","CHIMERA_NBAY","CHIMERA_NEPS","CHIMERA_NEPS12","CHIMERA_NEPS34","CHIMERA_NH","CHIMERA_NHUM","CHIMERA_NHVGT","CHIMERA_NLDP","CHIMERA_NMNP","CHIMERA_NMRK","CHIMERA_NMTP","CHIMERA_NQ","CHIMERA_NQDL","CHIMERA_NQS","CHIMERA_NSHL","CHIMERA_NSW","CHIMERA_NSYW1","CHIMERA_NVPP","CHIMERA_NWW2","CHIMERA_N_EMV","CHIMERA_N_HUNT","CHIMERA_N_WEST","CHIMERA_QBCG","CHIMERA_QBCK","CHIMERA_QBGH","CHIMERA_QCAA","CHIMERA_QCABC","CHIMERA_QGLD","CHIMERA_QGLD12","CHIMERA_QGLD34","CHIMERA_QKAH","CHIMERA_QLD","CHIMERA_QMKG","CHIMERA_QMSP","CHIMERA_QNDL","CHIMERA_QNS","CHIMERA_QOKY","CHIMERA_QRMA","CHIMERA_QSTN","CHIMERA_QSWB","CHIMERA_QSWE","CHIMERA_QTRN","CHIMERA_QTYP","CHIMERA_QWIV","CHIMERA_Q_CALL","CHIMERA_Q_CGS","CHIMERA_Q_CN","CHIMERA_Q_CS","CHIMERA_Q_FNQ","CHIMERA_Q_GC","CHIMERA_Q_NTH","CHIMERA_Q_RS","CHIMERA_Q_STH","CHIMERA_Q_TRNG","CHIMERA_SA","CHIMERA_SA_CENT","CHIMERA_SA_NTH","CHIMERA_SDCA","CHIMERA_SHPS","CHIMERA_SMPS","CHIMERA_SNOWY","CHIMERA_SNPA","CHIMERA_SPEW","CHIMERA_SPLN","CHIMERA_SPPT","CHIMERA_SPSD","CHIMERA_SQPS","CHIMERA_SSGA","CHIMERA_SV","CHIMERA_SVHY","CHIMERA_SVML","CHIMERA_TBAS","CHIMERA_TBBAY","CHIMERA_TCETH","CHIMERA_TDEVG","CHIMERA_TGORD","CHIMERA_TJBUT","CHIMERA_TLEM_WIL","CHIMERA_TLI_WY_CA","CHIMERA_TMBNK","CHIMERA_TMKNT","CHIMERA_TPOAT110","CHIMERA_TPOAT220","CHIMERA_TREECE","CHIMERA_TTARL","CHIMERA_TTRIB","CHIMERA_TTUNG","CHIMERA_VAPS","CHIMERA_VH","CHIMERA_VHUM","CHIMERA_VHWP","CHIMERA_VIC","CHIMERA_VJLG","CHIMERA_VLYABGS","CHIMERA_VMWP","CHIMERA_VMWT","CHIMERA_VNPS","CHIMERA_VS","CHIMERA_VSHY","CHIMERA_VTTS","CHIMERA_V_LV","CHIMERA_V_SH","CHI_EST_FCAS_L5","CHI_EST_FCAS_L6","CHI_EST_FCAS_L60","CHI_EST_FCAS_R5","CHI_EST_FCAS_R6","CHI_EST_FCAS_R60","CHI_EST_FCAS_RREG","CHI_NEM_FCAS_L5","CHI_NEM_FCAS_L6","CHI_NEM_FCAS_L60","CHI_NEM_FCAS_R5","CHI_NEM_FCAS_R6","CHI_NEM_FCAS_R60","CHI_NEM_FCAS_RREG","CHI_NSW_FCAS_L5","CHI_NSW_FCAS_L6","CHI_NSW_FCAS_L60","CHI_NSW_FCAS_R5","CHI_NSW_FCAS_R6","CHI_NSW_FCAS_R60","CHI_NSW_FCAS_RREG","CHI_QLDNSW_FCAS_L5","CHI_QLDNSW_FCAS_L6","CHI_QLDNSW_FCAS_L60","CHI_QLDNSW_FCAS_R5","CHI_QLDNSW_FCAS_R6","CHI_QLDNSW_FCAS_R60","CHI_QLDNSW_FCAS_RREG","CHI_QLD_FCAS_L5","CHI_QLD_FCAS_L6","CHI_QLD_FCAS_L60","CHI_QLD_FCAS_R5","CHI_QLD_FCAS_R6","CHI_QLD_FCAS_RREG","CHI_SAVIC_FCAS_L5","CHI_SAVIC_FCAS_L6","CHI_SAVIC_FCAS_L60","CHI_SAVIC_FCAS_R5","CHI_SAVIC_FCAS_R6","CHI_SAVIC_FCAS_R60","CHI_SAVIC_FCAS_RREG","CHI_SA_FCAS_L6","CHI_SA_FCAS_L60","CHI_SA_FCAS_R5","CHI_SA_FCAS_R6","CHI_SA_FCAS_R60","CHI_SA_FCAS_RREG","CHI_SNOWY_FCAS_L5","CHI_SNOWY_FCAS_L6","CHI_SNOWY_FCAS_L60","CHI_SNOWY_FCAS_R6","CHI_SNOWY_FCAS_R60","CHI_SNOWY_FCAS_RREG","CHI_STH_FCAS_L5","CHI_STH_FCAS_L6","CHI_STH_FCAS_L60","CHI_STH_FCAS_R5","CHI_STH_FCAS_R6","CHI_STH_FCAS_RREG","CHI_TAS_FCAS_L5","CHI_TAS_FCAS_L6","CHI_TAS_FCAS_L60","CHI_TAS_FCAS_LREG","CHI_TAS_FCAS_R5","CHI_TAS_FCAS_R6","CHI_TAS_FCAS_R60","CHI_TAS_FCAS_RREG","CHI_VIC_FCAS_L5","CHI_VIC_FCAS_L6","CHI_VIC_FCAS_L60","CHI_VIC_FCAS_LREG","CHI_VIC_FCAS_R5","CHI_VIC_FCAS_R6","CHI_VIC_FCAS_R60","CHI_VIC_FCAS_RREG","CH_857REACT_ONSTATUS","CI_CAP2_ONSTATUS","CLOVER.VMBT1","CLOVER_GEN","CLUNY.TCL11","CNUNDAWF.SSNN1","COLNSV_1_LOW_MW","COLNSV_1_ROCDN_MWPM","COLNSV_2.QCVL2","COLNSV_2_ROCDN_MWPM","COLNSV_3.QCVL3","COLNSV_3_LOW_MW","COLNSV_3_ROCDN_MWPM","COLNSV_4.QCVL4","COLNSV_4_LOW_MW","COLNSV_4_ROCDN_MWPM","COLNSV_5.QCVL5","COLNSV_5_LOW_MW","CPP_3.QCAC3","CPP_3_ONSTATUS","CPP_3_ROCDN_MWPM","CPP_4_ONSTATUS","DARTM1.VDPS","DDTS_220CAP_ONSTATUS","DDTS_330CAP2_ONSTATUS","DDTS_330_VOLTS","DDTS_H3_MVA","DG_NSW1.NDNSG","DG_SA1.SDNSG","DG_TAS1.TDNSG","DG_VIC1.VDNSG","DLINK_MVARS_T174TRA","DLINK_VARCONTROL","EILDON1.VEPS1","EILDON2.VEPS2","ER01.NEPS1","ER01_HIGH_MW","ER02_OFFER_MW","ER02_ROCUP_MWPM","ER03.NEPS3","ER03_HIGH_MW","ER03_OFFER_MW","ER03_ROCUP_MWPM","ER04.NEPS4","ER04_HIGH_MW","ER04_OFFER_MW","FBTS_SC1_OS","FISHER.TFI11","FISHER_ONSTATUS","GB01.NBKG1","GEN_BRKHLGT","GEN_SNOWY","GORDON.TGO11","GORDON1_MW","GORDON2_MW","GORDON3_MW","GORDON3_ONSTATUS","GORDON3_ONSTATUS_SC","GSTONE1_LOW_MW","GSTONE1_ONSTATUS","GSTONE1_ROCDN_MWPM","GSTONE2.QGLD2","GSTONE2_LOW_MW","GSTONE2_ONSTATUS","GSTONE2_ROCDN_MWPM","GSTONE3.QGLD3","GSTONE3_LOW_MW","GSTONE3_ONSTATUS","GSTONE3_ROCDN_MWPM","GSTONE4.QGLD4","GSTONE4_LOW_MW","GSTONE4_ONSTATUS","GSTONE4_ROCDN_MWPM","GSTONE5.QGLD5","GSTONE5_LOW_MW","GSTONE5_ONSTATUS","GSTONE5_ROCDN_MWPM","GSTONE6_LOW_MW","GSTONE6_ONSTATUS","GSTONE6_ROCDN_MWPM","GUTHEGA.NGUT8","HAMPSHIRE_CB_STATUS","HOFF_051+64_D","HOFF_051_D","HOFF_07+64_A","HOFF_64_1","HOFF_64_1X","HOFF_64_2","HOFF_64_2X","HOFF_64_3","HOFF_64_4","HOFF_64_4X","HOFF_64_A","HOFF_64_AX","HOFF_64_B","HOFF_64_BX","HOFF_64_C","HOFF_64_CX","HOFF_64_D","HOFF_64_DX","HOFF_64_G","HOFF_64_H","HOFF_64_J","HOFF_64_K","HOFF_64_L","HOFF_DDWO_A","HOFF_DDWO_B","HOFF_JNWG+X5_A","HOFF_JNWG+X5_B","HOFF_JNWG+X5_C","HOFF_JNWG+X5_D","HOFF_LOTF_A","HOFF_LOTF_B","HOFF_LTMS_A","HOFF_LTMS_AX","HOFF_LTMS_B","HOFF_LTMS_BX","HOFF_MSUT_1","HOFF_NIL_1","HOFF_NIL_1X","HOFF_NIL_2","HOFF_NIL_2X","HOFF_NIL_3","HOFF_NIL_3X","HOFF_NIL_4","HOFF_NIL_4X","HOFF_NIL_5","HOFF_NIL_5X","HOFF_NIL_6","HOFF_NIL_6X","HOFF_NIL_A","HOFF_NIL_AX","HOFF_NIL_B","HOFF_NIL_BX","HOFF_NIL_C","HOFF_NIL_CX","HOFF_NIL_D","HOFF_NIL_DX","HOFF_NIL_E","HOFF_NIL_EX","HOFF_NIL_F","HOFF_NIL_FX","HOFF_NIL_G","HOFF_NIL_H","HOFF_NIL_J","HOFF_NIL_K","HOFF_NIL_L","HOFF_NIL_M","HOFF_SNO_NSW_TU_ISL","HOFF_UTYS_B","HOFF_X_65_060_0X1_A","HOFF_X_65_060_0X1_B","HOFF_X_66_060_0X1_A","HOFF_X_66_060_0X1_B","HOTS_SVC_ONSTATUS","HUMENSW.NHUM","HUMENSW_HIGH_MW","HUMENSW_OFFER_MW","HUMENSW_ROCUP_MWPM","HUMEV.VHUM","HVGTS.NLD31","HVGTS_HIGH_MW","HVGTS_OFFER_MW","HVGTS_ROCUP_MWPM","HWPS1.VHWP1","HWPS5.VHWP5","HWPS7.VHWP7","HYTS_CAP_OS","INVICTA.QINV","IN_CAP_ONSTATUS","JBUTTERS_ONSTATUS","JINDABYN.PUMP.MW","JLA02.VJLGA2","JLA04.VJLGA4","JLB03.VJLGB3","KAREEYA1_ROCDN_MWPM","KAREEYA2.QKAH2","KAREEYA2_LOW_MW","KAREEYA3_ROCDN_MWPM","KAREEYA4.QKAH4","KAREEYA4_LOW_MW","KAREEYA_QKYH5_MW","KOOLKHAN_LOAD","KV_132_AR","LADBROK2.SPEW2","LAVNORTH.VAT21","LD01.NLDP1","LD01_OFFER_MW","LD02_OFFER_MW","LD03_HIGH_MW","LD04_HIGH_MW","LD04_OFFER_MW","LEMONTHYME_ONSTATUS","LEMONTME.TSH19","LIDDELL_330_KV","LINDISF_CAP1_STATUS","LISMORE_TX1","LISMORE_TX2","LKBONNY1.SMAY1","LOAD_BATS","LOAD_GNTS","LOAD_GTS","LOAD_KGTS","LOAD_MBTS","LOAD_MVAR_BATS_BAN2","LOAD_MVAR_BATS_TX2","LOAD_MVAR_GNTS_TX2","LOAD_MVAR_HOTS_TX2","LOAD_MVAR_KGTS_66_TX2","LOAD_MVAR_KGTS_66_TX3","LOAD_MVAR_RCTS_22_TX2","LOAD_MVAR_SHTS_TX3","LOAD_MVAR_TGTS_TX1","LOAD_PTH_A1","LOAD_WOTS","LOYYB1.VLYP5","LT_PUMP","LYA1.VLYP1","LYA4.VLYP4","MACKAYGT.QMKG","MACKAYGT_ROCDN_MWPM","MACKNTSH.TMA11","MACKNTSH_ONSTATUS","MCKAY2.VMKP2","MEADOWBANK_ONSTATUS","MEADOWBK.TMB11","MLTS_500_VOLTS","MLTS_ROI1_OS","MM3_ROCUP_MWPM","MM4.NMNP4","MM4_OFFER_MW","MMSTIMESTAMP","MMSTIMESTAMP_DS1","MMSTIMESTAMP_DS2","MMSTIMESTAMP_DS3","MMSTIMESTAMP_DS4","MOR2.VMWP4","MP2.NMTP2","MP2_OFFER_MW","MPP_1.QBCK1","MPP_1_LOW_MW","MPP_1_ONSTATUS","MPP_2_LOW_MW","MSS_S_GEN_SUM","MSTUART1_LOW_MW","MSTUART2.QMSP2","MSTUART2_LOW_MW","MSTUART2_ONSTATUS","MTMILLAR.SMTM1","MTMILL_MW","MVAR_BH_GEN2","MVAR_BH_SVC2","MVAR_BU_X2","MVA_BU_TX3","MVA_BW_LF","MVA_CS_TX3","MVA_HA_GT1","MVA_LF_RI1","MVA_LI_CS","MVA_MB_NN","MVA_NN_CR","MVA_NN_CS","MVA_SH_GT1","MVA_SH_TX2","MVA_TA_NN1","MVA_TA_NN2","MVA_WA_BW","MVA_WA_LF","MVA_WA_PM","MWS_BW_73","MWS_ER_25","MWS_ER_5A1","MWS_ER_5A2","MWS_KC_14","MWS_MM_26","MWS_MP_35","MWS_MP_36","MWTS_B3TR_MW","MW_AR_86","MW_AR_TX3","MW_AR_TX4","MW_BU_X2","MW_BW_31","MW_BW_32","MW_BW_73","MW_BW_74","MW_ER_93","MW_GT_CO5","MW_GT_TX2+3","MW_HYTS_MLTS1","MW_LD_82","MW_LD_84","MW_LOAD_TW","MW_LS_967","MW_MN_5","MW_MP_94Y","MW_MS_65","MW_NC_96A","MW_NC_96U","MW_NC_9NA","MW_ON_99A_TO_WG","MW_TO_132_AT_DP","MW_VP_23","MW_WG_994","MW_WG_99A","MW_WG_99F","MW_WG_TX1","MW_YS_02","MW_YS_TX1","N-Q-MNSP1","NO_BELLBAY","NO_CLUNY","NO_LAKE_ECHO","NO_M11_M14_SC","NO_MEADOWBANK","NO_REECE","NO_SOM_UNITS","NO_T1_GEN_IS","NO_T2_GEN_IS","NO_T2_SC","NO_TREVALLYN","NO_TUNGATINAH","NO_WKPS","NSW1","NSW1-QLD1","NSW_L01_ONSTATUS","NSW_L03_ONSTATUS","NSW_L64_ONSTATUS","NSW_L65_ONSTATUS","NSW_L66_ONSTATUS","NSW_L8C_ONSTATUS","NSW_L8E_ONSTATUS","NSW_L8L_ONSTATUS","NSW_L8M_ONSTATUS","NSW_SW_AREA_MW","N_LISMSVC_MVARS","OAKEY1_LOW_MW","OAKEY2.QOKY2","OAKEY2_LOW_MW","ONSTATUS_ECS_DLNK","PALOONA.TPA11","PARA_SVC_RES","PIONEER.QTVS","PLAYB-AG.SPSD1","POAT110.TPM21","PPCCGT.SPPT","PPCCGT11_ONSTATUS","PPCCGT12_ONSTATUS","PPCCSTEAM18_ONSTATUS","PTH01.VPTH1","PTH02.VPTH2","PTH03.VPTH3","QBGH1_ONSTATUS","QBGH2_ONSTATUS","QCAC_SUMM_INERT","QCOLL_PS_SUM_MW","QFLOW_CN","QFLOW_CNNEBO","QFLOW_CNNEBO_AVER","QFLOW_CS","QFLOW_CST","QFLOW_GOLD_COAST","QFLOW_ROSS_COLL","QFLOW_T_SOUTH","QGCECS_SUM_RATESTAT","QGEN_CEN","QGEN_NOR","QGLD_SUMM_INERT","QKAH1_ONSTATUS","QKAH2_ONSTATUS","QKAH3_ONSTATUS","QKAH4_ONSTATUS","QLD1","QLD1_AGC_LOWER","QLD1_AGC_RAISE","QLD_9901_ONSTATUS","QLD_9902_ONSTATUS","QLD_LARGEST_MW","QLD_R2_TX1_ONSTATUS","QLD_R2_TX2_ONSTATUS","QLINE707_MW","QLINE709_MW","QLINE711_MW","QLINE712_MW","QLINE7132_MW","QLINE7133_MW","QLINE715_MW_LMT","QLINE717_MW_LMT","QLINE718_MW_LMT","QLINE7276_MW","QLINE7277_MW","QLINE731_MVA","QLINE752_MW","QLINE758_H4MU_MW","QLINE758_T174TE_MW","QLINE803_SBMW","QLINE804_MW","QLINE806_H1SB_MW","QLINE806_H4MU_MW","QLINE817_MW","QLINE855_MW","QLINE9908_MW","QOKY_SUMM_INERT","QPS1.SQPS1","QPS2.SQPS2","QPS4.SQPS4","QSUM_TARONGLIMIT","QTRF1_H14MR_MW","QTRF2_3_H14MR_MW","QTRF4_H22LL_MW","QTRF8_SSBBS110KV_MW","QTRN_SUMM_INERT","Q_BCMB_LINE_7106","Q_BLKSVC_MVARS","Q_BRAESVC_MVARS","Q_BRAESVC_ONSTATUS","Q_BRTX1_MVA","Q_DIRLK_H1SWB805_806","Q_DIRLK_H31MDNR_TRFMR","Q_DIRLK_H4MUG_TRFMRS","Q_DIRLK_T174TA757_758","Q_DIRLK_T91MDNR_7193","Q_GLAD_TRAN_1BT","Q_GLAD_TRAN_2BT","Q_H11NE_8RX_ONSTATUS","Q_H12ME_8CP1_AVLSTAT","Q_H16RL_7CP1_AVLSTAT","Q_H16RL_7CP2_AVLSTAT","Q_H22LL_7CP4_AVLSTAT","Q_H22LL_7CP4_ONSTATUS","Q_H22LL_7CP5_AVLSTAT","Q_H22LL_7CP5_ONSTATUS","Q_H22LL_7CP7_ONSTATUS","Q_H24CALV_KVACT","Q_H2SP_7CP1_AVLSTAT","Q_H2SP_7CP1_ONSTATUS","Q_H2SP_7CP2_AVLSTAT","Q_H2SP_7CP2_ONSTATUS","Q_H2SP_7CP5_ONSTATUS","Q_H2SP_8CP3_AVLSTAT","Q_H2SP_8CP3_ONSTATUS","Q_H2SP_8CP4_AVLSTAT","Q_H2SP_8CP4_ONSTATUS","Q_H31MD_7CP4_AVLSTAT","Q_H32CH_7CP1_AVLSTAT","Q_H36BK_8CP5_AVLSTAT","Q_H36BK_8CP5_ONSTATUS","Q_H36BK_8CP6_AVLSTAT","Q_H36BK_8CP6_ONSTATUS","Q_H36BLK_KVACT","Q_H3BM_7CP1_AVLSTAT","Q_H3BM_7CP1_ONSTATUS","Q_H3BM_7CP2_AVLSTAT","Q_H3BM_7CP2_ONSTATUS","Q_H3BM_7CP5_ONSTATUS","Q_H3BM_8CP3_AVLSTAT","Q_H3BM_8CP3_ONSTATUS","Q_H3BM_8CP4_AVLSTAT","Q_H3BM_8CP4_ONSTATUS","Q_H4MU_7CP1_AVLSTAT","Q_H4MU_7CP2_AVLSTAT","Q_H4MU_7CP3_AVLSTAT","Q_H4MU_8CP4_AVLSTAT","Q_H4MU_OLMS_AVLSTAT","Q_H7GLAD_KVACT","Q_H9PW_7CP1_AVLSTAT","Q_H9PW_7CP1_ONSTATUS","Q_H9PW_7CP2_AVLSTAT","Q_H9PW_7CP2_ONSTATUS","Q_H9PW_7CP4_ONSTATUS","Q_H9PW_8CP3_AVLSTAT","Q_H9PW_8CP3_ONSTATUS","Q_R2BR_8CP2_AVLSTAT","Q_ROSS_SVC_MVARS","Q_ROSS_SVC_ONSTATUS","Q_T155WD_7CP1_ONSTAT","Q_T155WD_7CP2_ONSTAT","Q_T155WD_7CP3_ONSTAT","Q_T24RN_7CP2_ONSTATUS","Q_T30AW_7CP2_ONSTATUS","Q_T30AW_7CP3_ONSTATUS","Q_T81CC_7283_MW","Q_TGLMT3_OFFSET","Q_TGLMT4_OFFSET","Q_TGLMT7_OFFSET","Q_TG_ADLMT","Q_TG_DYNLMT","Q_TG_ENTERED_LMT","REDBANK1.NMRK1","REDBANK1_HIGH_MW","REECE1.TRCA1","REECE2.TRCB1","REPULSE.TCL12","REPULSE_ONSTATUS","RISDON_CAP1_STATUS","ROMA_7.QRMA7","ROMA_7_LOW_MW","ROMA_8.QRMA8","ROMA_8_LOW_MW","ROTS_SVC1_OS","ROTS_SVC2_OS","ROTS_SVC_OS","ROWALLAN_GEN","RT_NSW1.NRT1","RT_QLD1.QRT1","RT_SA1.SRT1","RT_SA2.SART2","RT_SA3.SART3","RT_SA4.SART4","RT_SA5.SART5","RT_SA6.SART6","RT_TAS1.TRT1","RT_VIC10.VICRT10","RT_VIC11.VICRT11","RT_VIC12.VICRT12","RT_VIC2.VICRT2","RT_VIC3.VICRT3","RT_VIC5.VICRT5","RT_VIC6.VICRT6","RT_VIC8.VICRT8","RT_VIC9.VICRT9","RUBICON.VTT21R","SA1","SA_INERT","SA_MET_CAP","SA_RIVERLAND_LOAD","SESS_SVC_RES","SE_SUMLOAD_MW","SE_SVC1_OS","SE_SVC2_OS","SHGEN.NSHL","SHGEN_HIGH_MW","SHGEN_ROCUP_MWPM","SHPUMP.NSHP1","SITHE01_OFFER_MW","SMTS_F2_MVA","SMTS_F2_TAP_NUM","SNOWY1","SNOWY1_AGC_LOWER","SNOWY1_FLOW","SNOWYGJP.NGJP","SNOWYP.NLTS3","SNOWY_INERT","STAN-1.QSTN1","STAN-1_LOW_MW","STAN-2.QSTN2","STAN-2_LOW_MW","STAN-3_LOW_MW","STAN-4.QSTN4","STAN-4_LOW_MW","STARHLWF.SMVE2","STATUS_BU_REAC_R2","SWAN_B_1.QSWB1","SWAN_B_1_LOW_MW","SWAN_B_2.QSWB2","SWAN_B_2_LOW_MW","SWAN_B_3.QSWB3","SWAN_B_3_LOW_MW","SWAN_B_3_ROCDN_MWPM","SWAN_B_4.QSWB4","SWAN_B_4_LOW_MW","SWAN_B_4_ROCDN_MWPM","SWAN_E.QSWE","SWAN_E_LOW_MW","SWAN_E_ONSTATUS","S_BRIMIN_ST","S_BRPA_MVA","S_DVRB2_MVA","S_KEISNG_ST","S_KETB2_MVA","S_KHSN_SMVA","S_KHTB1_SMVA","S_KHTB2_SMVA","S_MIKANC_ST","S_MINWAT_ST","S_MNAC_MVA","S_MONNWB1_MVA","S_MTBLA_ST","S_MTBL_SMVA","S_NWBMON1_MVA","S_PARA_RSWTHY132_MW","S_PATB1_SMVA","S_PATB2_SMVA","S_ROBTX1_MW","S_SET2_MVA","S_SETB1_SMVA","S_SNGBLA_ST","S_SNUGTX1_MW","S_SNUGTX2_MW","S_SNUGTX4_MW","S_TBT4_MVA","T-V-MNSP1","TAMWORTH_CAP1_STATUS","TAM_LOAD","TARONG#1_LOW_MW","TARONG#2.QTRN2","TARONG#2_LOW_MW","TARONG#3_LOW_MW","TARONG#3_ROCDN_MWPM","TARONG#4.QTRN4","TARONG#4_LOW_MW","TAS1_AGC_LOWER","TAS1_FCAS_MG_R5","TAS1_FCAS_MG_R6","TAS1_FCAS_MG_R60","TAS1_FCAS_ML_L5","TAS1_FCAS_ML_L6","TAS1_FCAS_ML_L60","TAS1_FCAS_TGFASH1_R5","TAS1_FCAS_TGFASH1_R6","TAS1_FCAS_TGFASH1_R60","TAS1_FCAS_TGFASH2_R5","TAS1_FCAS_TGFASH2_R6","TAS1_FCAS_TGFASH2_R60","TAS1_FCAS_TGTULEBGR60","TAS1_FCAS_TGTULEBG_R5","TAS1_FCAS_TGTULEBG_R6","TAS1_FCAS_TG_BBGT_R5","TAS1_FCAS_TG_BBGT_R6","TAS1_FCAS_TG_BBGT_R60","TAS1_FCAS_TG_BELL_R5","TAS1_FCAS_TG_BELL_R6","TAS1_FCAS_TG_GOR_R5","TAS1_FCAS_TG_GOR_R6","TAS1_FCAS_TG_GOR_R60","TAS1_FCAS_TG_GTTX_R5","TAS1_FCAS_TG_GTTX_R6","TAS1_FCAS_TG_GTTX_R60","TAS1_FCAS_TLCOMBB_L5","TAS1_FCAS_TLCOMBB_L6","TAS1_FCAS_TLCOMBB_L60","TAS1_FCAS_TL_2COM_L5","TAS1_FCAS_TL_2COM_L6","TAS1_FCAS_TL_3COM_L5","TAS1_FCAS_TL_3COM_L6","TAS1_FCAS_TL_3COM_L60","TAS_FCSPS_STATUS","TAS_GEN+NON_SCHED","TAS_NCSPS_ID1_STAT","TAS_NCSPS_ID21_STAT","TAS_NCSPS_ID2_STAT","TAS_NCSPS_ID31_STAT","TAS_NCSPS_ID33_STAT","TAS_NCSPS_ID34_STAT","TAS_NCSPS_ID35_STAT","TAS_NCSPS_ID51_STAT","TAS_NCSPS_ID53_STAT","TAS_NCSPS_ID71_STAT","TAS_NCSPS_ID73_STAT","TAS_NCSPS_ID74_STAT","TAS_NCSPS_ID75_STAT","TAS_NCSPS_ID81_STAT","TAS_NCSPS_ID83_STAT","TAS_NCSPS_ID91_STAT","TAS_NCSPS_ID92_STAT","TAS_NCSPS_LICL_FIRM","TAS_NCSPS_LICS2_FIRM","TAS_NCSPS_LIPM1_FIRM","TAS_NCSPS_LIPM2_FIRM","TAS_NCSPS_PMHA1_FIRM","TAS_NCSPS_PMHA2_FIRM","TAS_NCSPS_PMHA3_FIRM","TAS_NCSPS_PMHA4_FIRM","TAS_NCSPS_SHFA1_FIRM","TAS_NCSPS_SHFA2_FIRM","TAS_NCSPS_SHGT1_FIRM","TAS_NCSPS_STATUS","TAS_PMSH_ONSTATUS","TAS_SHFA2_ONSTATUS","TAS_SHGT1_ONSTATUS","TAS_SHGT2_ONSTATUS","TBEND_TF1_MW","TBEND_TF2_MW","TNPS1_LOW_MW","TORRA1.STSA1","TORRA2.STSA2","TORRA3.STSA3","TORRB1.STSB1","TORRB2.STSB2","TORRB3.STSB3","TRBK_LMT_OFFSET","TREVALLN.TTR11","TRIBUTE_ONSTATUS","TRLOAD_GT","TRLOAD_NW","TRLOAD_PA","TRLOAD_S","TRLOAD_SX","TRLOAD_TE","TRLOAD_TR","TRLOAD_WC","TSTS_SC1","TUMUT1_2_IN","TUMUT3-1.NLTS31","TUMUT3-2.NLTS32","TUMUT3-3.NLTS33","TUMUT3-4.NLTS34","TUMUT3-5.NLTS35","TUMUT3-6.NLTS36","TUMUT3.NLTS8","TUNGA_3.TTU18","TUNGA_4.TTU19","UVLS1_ONSTATUS","UVLS2_ONSTATUS","UVLS3_ONSTATUS","V-S-MNSP1","V-SA","V-SN","VIC1","VIC1_AGC_LOWER","VIC1_AGC_RAISE","VIC_INERT","VIC_LARGEST_MW","VIC_State_Grid_Load","VP5.NVPP5","VP5_HIGH_MW","VP5_ROCUP_MWPM","VP6.NVPP6","VP6_HIGH_MW","VP6_OFFER_MW","VP6_ROCUP_MWPM","VPGS.VLYP7","VRAT5M_BAML1","VRAT5M_DDMS2","VRAT5M_GTKT1","VRAT5M_GTKT2","VRAT5M_GTKT3","V_SMKT_MW","W/HOE#1_LOW_MW","W/HOE#1_ROCDN_MWPM","W/HOE#2.QWIV2","W/HOE#2_LOW_MW","W/HOE#2_ROCDN_MWPM","WAGGA_AREA_CAPS_NIS","WATTPT_MW","WG01.NWGB","WILMOT_ONSTATUS","WIV1GEN/SC_ONSTATUS","WIV2GEN/SC_ONSTATUS","WIVPUMP1_ONSTATUS","WIVPUMP2_ONSTATUS","WKIEWA1.VWKP1","WKIEWA2.VWKP2","WOOLNORTH_GEN","WOOLNTH1.TST11","WOPW_LMT_OFFSET","WOTS_330CAP_ONSTATUS","WPWF.SSYP1","WW7_HIGH_MW","WW7_OFFER_MW","WW7_ROCUP_MWPM","WW8.NWW28","WW8_HIGH_MW","WW8_OFFER_MW","WW8_ROCUP_MWPM","YABULU2.QGAR1","YABULU_LOW_MW","YABULU_ONSTATUS","YAMBUKWF.VTGT1","YWPS1.VYP21","YWPS1_220_ON","YWPS1_500_ON","YWPS2.VYP22","YWPS3.VYP23","YWPS4.VYP24"]},"SPD_TYPE":{"sql_type":"VARCHAR(1)","pl_type":"pl.Categorical","mandatory":true,"comment":"ID describing type of data source","examples":["A","I","R","S","T"]},"DESCRIPTION":{"sql_type":"VARCHAR(255)","pl_type":"str","mandatory":false,"comment":"The detailed description of the SCADA point associated with the SPD_ID","examples":["AGC Lower from Qld Generators","AGC Lower from Snowy Generators","AGC Lower from Tasmanian Generators","AGC Lower from Victorian Generators","AGC Raise from Qld Generators","AGC Raise from Victorian Generators","Aggregate Broken Hill Gas Turbines Unit 1 & 2 (SCADA)","Angas Creek - Para line ON status","Angaston GT unit 2","Availability status of Belmont #1 110kV Cap Bank","Availability status of Belmont #2 110kV Cap Bank","Availability status of Belmont #3 275kV Cap Bank","Availability status of Belmont #4 275kV Cap Bank","Availability status of Blackwall #5 275kV Cap Bank","Availability status of Blackwall #6 275kV Cap Bank","Availability status of Braemar #2 275kV Cap Bank","Availability status of Chalumbin #1 132kV Cap Bank","Availability status of Loganlea #4 110kV Cap Bank","Availability status of Loganlea #5 110kV Cap Bank","Availability status of Molendinar #4 132kV Cap Bank","Availability status of Mt England #1 275kV Cap Bank","Availability status of Mudgeeraba #1 110kV Cap Bank","Availability status of Mudgeeraba #2 110kV Cap Bank","Availability status of Mudgeeraba #3 110kV Cap Bank","Availability status of Mudgeeraba #4 275kV Cap Bank","Availability status of Palmwoods #1 132kV Cap Bank","Availability status of Palmwoods #2 132kV Cap Bank","Availability status of Palmwoods #3 275kV Cap Bank","Availability status of Rocklea #1 110kV Cap Bank","Availability status of Rocklea #2 110kV Cap Bank","Availability status of South Pine #1 110kV Cap Bank","Availability status of South Pine #2 110kV Cap Bank","Availability status of South Pine #3 275kV Cap Bank","Availability status of South Pine #4 275kV Cap Bank","Average summated MW flows for 275kv fdrs 845, 834, 821 (flow in Southerly direction)","BATS-MLTS #1 line 5 min MVA rating at BATS - telemetered value","Barcaldine GT","Barron Gorge hydro unit 2","Basslink frequency controller set to 50Hz on Tasmanian side","Basslink previous dispatch interval target (MW)","Bayswater unit 2","Bell Bay GT unit 1","Bell Bay GT unit 2","Blanche - Snuggery line status","Braemar 1 GT unit 1","Braemar 1 GT unit 2","Brinkworth to Para 275 kV line MVA flow, Line end switched MVA","Broken Hill GT1 and GT2 MW output","Burrinjuck MW output","Burrinjuck PS (SCADA)","Butlers MW output","CHIMERA analog","Calculation for the MW value of the largest Qld generator","Callide A unit 4","Callide B unit 2","Callide C unit 3","Canunda WF (MW)","Canunda Windfarm generation","Cathedral Rocks WF (MW)","Cathedral Rocks windfarm generation MW","Clover PS (SCADA)","Clover Power Station","Collinsville unit 2","Collinsville unit 3","Collinsville unit 4","Collinsville unit 5","DDTS-MSS #2 line 5 min MVA rating at DDTS - telemetered value","Dartmouth hydro","Davenport to Robertstown 275kV line MVA flow, Line end switched MVA","Directlink MVAr transfer at Bungalora","Dummy entry for reserve trader","EMS offset for Tarong Constraint (emergency use only)","Eildon hydro unit 1","Eildon hydro unit 2","Eraring unit 1","Eraring unit 3","Eraring unit 4","Firm flow enablement status for LICL line","Firm flow enablement status for LICS No.2 line","Firm flow enablement status for LIPM No.1 line","Firm flow enablement status for LIPM No.2 line","Firm flow enablement status for PMHA No.1 line","Firm flow enablement status for PMHA No.2 line","Firm flow enablement status for PMHA No.3 line","Firm flow enablement status for PMHA No.4 line","Firm flow enablement status for SHFA No.1 line","Firm flow enablement status for SHFA No.2 line","Firm flow enablement status for SHGT No.1 line","Fisher hydro","GTS-KTS #1 line 5 min MVA rating at GTS - telemetered value","GTS-KTS #2 line 5 min MVA rating at GTS - telemetered value","GTS-KTS #3 line 5 min MVA rating at GTS - telemetered value","Gladstone unit 2","Gladstone unit 3","Gladstone unit 4","Gladstone unit 5","Gordon hydro (3 aggregated units)","Guthega hydro (2 aggregated units)","H11 Nebo 275kV Line 821 20MVAr reactor on/off status","H13 Ross SVC dispatched MVArs","H13 Ross SVC on/off status","H36 Blackwall Node 1 bus voltage (kV)","Hallet GT (13 aggregated units)","Hazelwood unit 1","Hazelwood unit 5","Hazelwood unit 7","Hume (NSW) hydro","Hume (Vic) hydro","Hunter GT (2 aggregated units)","Inertia of Bayswater PS","Inertia of Generators on line in SA","Inertia of Generators on line in Victoria","Inertia of Oakey PS","Inertia of Para SVC","Inertia of Tumut 1_2 Generators","Invicta Sugar Mill","Jeeralang A GT unit 2","Jeeralang A GT unit 4","Jeeralang B GT unit 3","Jindabyne Pumps - for LHS FCAS use only","Kareeya hydro unit 2","Kareeya hydro unit 4","Keith - Snuggery 132 kV line SMVA flow","Keith - Tailem Bend 132 kV line #1 SMVA flow","Keith - Tailem Bend 132 kV line #2 SMVA flow","Ladbroke Grove GT unit 2","Lake Bonney 1 WF (MW)","Laverton North GT (2 aggregated units)","Liddell unit 1","Load on the 132/66 kV transformers at Koolkhan","Lower Tumut hydro (6 aggregated units)","Lower Tumut pumps (3 aggregated pumps)","Loy Yang A unit 1","Loy Yang A unit 4","Loy Yang B unit 1","MVA flow on #1 Hadspen to George Town 220kV line at Hadspen, Line end switched MVA","MVA flow on #1 Sheffield to George Town 220kV line at Sheffield, Line end switched MVA","MVA flow on #2 Liapootah to Chapel St 220kV line at Liapootah, Line end switched MVA","MVA flow on South Morang 500/330kV (F2) transformer","MVA flow on the Bridgewater to Lindisfarne 110kV line from Bridgewater, line end switched MVA","MVA flow on the Lindisfarne to Risdon No.1 110kV line from Lindisfarne, line end switched MVA","MVA flow on the Meadowbank to New Norfolk 110kV line from New Norfolk, line end switched MVA","MVA flow on the New Norfolk to Chapel St 110kV line from New Norfolk, line end switched MVA","MVA flow on the New Norfolk to Creek Rd 110kV line from New Norfolk, line end switched MVA","MVA flow on the Tarraleah to New Norfolk No.1 110kV line from New Norfolk, line end switched MVA","MVA flow on the Tarraleah to New Norfolk No.2 110kV line from New Norfolk, line end switched MVA","MVA flow on the Waddamana to Bridgewater 110kV line from Waddamana, line end switched MVA","MVA flow on the Waddamana to Lindisfarne 110kV line from Waddamana, line end switched MVA","MVA flow on the Waddamana to Palmerston 110kV line from Palmerston, Line end switched MVA","MVA on 731 110kV feeder from Tangkam, Line end switched MW","MVA on Braemar #1 330/275kV transformer","MVA on Burnie #3 220/110kV transformer","MVA on Chapel St #3 220/110kV transformer","MVA on Dederang 330/220kV (H3) transformer","MVA on Monash to North West Bend #1 132kV line from Monash, Line end switched MW","MVA on North West Bend to Monash #1 132kV line from North West Bend, Line end switched MVA","MVA on Sheffield #2 220/110kV transformer","MVA on South East #2 275/132 kV transformer","MVA on Tailem Bend #4 275/132 kV transformer","MVAr Reserve at South East SVC","MVAr flow on Ballarat #2 220/66kV transformer","MVAr flow on Ballarat to Ballarat North #2 66kV line","MVAr flow on Glenrowan No.2 220/66kV transformer","MVAr flow on Horsham #2 220/66kV transformer","MVAr flow on Kerang #2 220/66kV transformer","MVAr flow on Kerang #3 220/66kV transformer","MVAr flow on Red Cliffs #2 220/22kV transformer","MVAr flow on Shepparton #3 220/66kV transformer","MVAr flow on Terang #1 220/66kV transformer","MVAr flow on X2 220kV line from Buronga","MVAr output of Blackwall SVC","MVAr output of Braemar SVC","MVAr output of Broken Hill GT 2","MVAr output of Broken Hill SVC 2","MVAr output of Lismore SVC","MW Load at Geelong","MW Load at Glenrowan","MW Load at Kerang","MW Load at Mount Beauty. Includes output of Clover Power Station","MW Load in the SA Riverland area","MW Load of Victorian State Grid Load","MW flow Geelong to Point Henry #1 220kV line at Point Henry, Line end switched MW","MW flow for 110kV feeder 7283 at Cades County, line end switched MW","MW flow north on Snowy1 interconnector","MW flow north on Vic-Snowy AC Interconnector","MW flow north on the Basslink DC Interconnector","MW flow north on the QNI AC Interconnector","MW flow north on the Snowy1 AC Interconnector","MW flow on #1 275/110kV transformer at H14 Middle Ridge","MW flow on #2 and #3 275/110kV transformers at H14 Middle Ridge","MW flow on #4 275/110kV transformer at H22 Loganlea","MW flow on #8 110kV transformer at Belmont","MW flow on 02 330kV line at Yass, Line end switched MW","MW flow on 14 330kV line at Kemps Creek, Line end switched MW","MW flow on 23 330kV line at Vales Point, Line end switched MW","MW flow on 25 330kV line at Eraring, Line end switched MW","MW flow on 26 330kV line at Munmorah, Line end switched MW","MW flow on 35 330kV line at Mt Piper, Line end switched MW","MW flow on 36 330kV line at Mt Piper, Line end switched MW","MW flow on 5 330kV line at Marulan, Line end switched MW","MW flow on 5A1 500kV line at Eraring, Line end switched MW","MW flow on 5A2 500kV line at Eraring, Line end switched MW","MW flow on 65 330kV line at Murray PS, Line end switched MW","MW flow on 707 110kV feeder at West Darra, Line end switched MW","MW flow on 709 110 kV feeder at Richlands","MW flow on 7106 132kV feeder at Bouldercombe, Line end switched MW","MW flow on 711 110kV feeder at Middle Ridge","MW flow on 7132 132kV feeder at Townsville","MW flow on 7133 132kV feeder at Townsville, line end switched MW","MW flow on 7193 110kV feeder at Molendinar","MW flow on 7276 132kV feeder at Townsville, line end switched MW","MW flow on 7277 132kV feeder at Townsville, line end switched MW","MW flow on 73 330kV line at Bayswater, Line end switched MW","MW flow on 752 110kV feeder at Belmont","MW flow on 758 110kV feeder at Mudgeeraba, Line end switched MW","MW flow on 758 110kV feeder at Terranora, Line end switched MW","MW flow on 803 275kV feeder at Swanbank, Line end switched MW","MW flow on 804 275kV feeder at Swanbank, Line end switched MW","MW flow on 806 275kV feeder at Mudgeeraba, Line end switched MW","MW flow on 806 275kV feeder at Swanbank, Line end switched MW","MW flow on 817 275kV feeder at Blackwall, Line end switched MW","MW flow on 82 330kV line at Liddell, Line end switched MW","MW flow on 84 330kV line at Liddell, Line end switched MW","MW flow on 855 275kV feeder at Calvale, Line end switched MW","MW flow on 86 330kV line at Armidale, Line end switched MW","MW flow on 93 330kV line at Eraring, Line end switched MW","MW flow on 94Y 132kV line at Mt Piper","MW flow on 96A 132kV line at Newcastle","MW flow on 96U 132kV line at Newcastle","MW flow on 994 132kV line at Wagga 330","MW flow on 99A 132kV line at Wagga 330","MW flow on 99F 132kV line at Wagga 330","MW flow on 9NA 132kV line at Newcastle","MW flow on Armidale #3 330/132kV transformer","MW flow on Armidale #4 330/132kV transformer","MW flow on George Town to Comalco #5 220kV line","MW flow on Gladstone #1 275/132kV transformer measured on 132kV bus","MW flow on Gladstone #2 275/132kV transformer measured on 132kV bus","MW flow on HYTS-MLTS #1 500kV line at Heywood, MW flow at HYTS end","MW flow on Lismore #1 330/132kV transformer","MW flow on Lismore #2 330/132kV transformer","MW flow on Molendinar 275/110kV transformer","MW flow on Para to Roseworthy 132kV line at Para, Line end switched MVA","MW flow on Robertstown #1 275/132kV transformer","MW flow on Snuggery #1 33/132kV transformer","MW flow on Snuggery #2 33/132kV transformer","MW flow on Snuggery #4 33/132kV transformer","MW flow on Tailem Bend #1 132/33 kV transformer","MW flow on Tailem Bend #2 132/33 kV transformer","MW flow on Wagga #1 330/132kV transformer","MW flow on X2 220kV line at Buronga, Line end switched MW","MW flow on Yass #1 330/132kV transformer","MW flow on both 330/132kV transformers at Darlington Point","MW flow on both George Town 220/110kV transformers","MW flow west on the Murraylink DC Interconnector","MW flow west on the Vic-SA AC interconnector","MW load at Ballarat. 66 kV txfmr flow plus 50% of output of Challicum Hills wind farm.","MW load of Capral Potline #2","MW load of Nyrstar Industrial Load ex Risdon","MW load of SouthernX area (Derwent Bridge, Meadowbank, Kingston, Electrona, Knights Rd, Kermandie, Southwood, New Norfolk area)","MW load of Temco potlines","MW load of Trevallyn area (Trevallyn, Mowbray, Aurora)","MW load on Pumps at Jindabyne","MW load supplied directly from George Town (George Town, Starwood, Comalco, Temco)","Mackay GT","Mackintosh hydro","Manually selectable MW transfer limit reference for 110kV feeder 715 ","Manually selectable MW transfer limit reference for 110kV feeder 717","Manually selectable MW transfer limit reference for 110kV feeder 718","Manually selectable Var/Voltage control mode status; 1= var control","Max voltage of the 330kV line voltages at Dederang","Maximum available MW generation for Hume NSW PS","Maximum available MW generation for Hunter GTs","Maximum available MW generation for Sithe PS","Maximum available MW generation for unit 1 Bayswater PS","Maximum available MW generation for unit 1 Liddell PS","Maximum available MW generation for unit 2 Bayswater PS","Maximum available MW generation for unit 2 Eraring PS","Maximum available MW generation for unit 2 Liddell PS","Maximum available MW generation for unit 2 Mt Piper PS","Maximum available MW generation for unit 3 Bayswater PS","Maximum available MW generation for unit 3 Eraring PS","Maximum available MW generation for unit 4 Eraring PS","Maximum available MW generation for unit 4 Liddell PS","Maximum available MW generation for unit 4 Munmorah PS","Maximum available MW generation for unit 6 Vales Pt PS","Maximum available MW generation for unit 7 Wallerawang PS","Maximum available MW generation for unit 8 Wallerawang PS","McKay hydro (units 2 & 4 aggregated) - deregistered - incorporated in MKAY1","Meadowbank hydro","Measured South East MW Load","Millmerran unit 1","Mintaro - Brinkworth line ON status","Mintaro - Waterloo line status","Moorabool 500kV voltage","Morwell #3 220/66 transformer load MW","Morwell unit 4","Mt Gambier - Blanche 132 kV line SMVA flow","Mt Gambier - Blanche line ON status","Mt Millar WF (MW)","Mt Millar windfarm generation MW","Mt Piper unit 2","Mt Stuart GT unit 2","Munmorah unit 4","NCSPS enablement status for FASH No.1 on trip of FASH No.2 trip","NCSPS enablement status for FASH No.2 on trip of FASH No.1 trip","NCSPS enablement status for GOCS No.1 on trip of GOCS No.2 trip","NCSPS enablement status for GOCS No.2 on trip of GOCS No.1 trip","NCSPS enablement status for HAGT No.1 on trip of HAGT No.2 trip","NCSPS enablement status for HAGT No.1 on trip of PMSH trip","NCSPS enablement status for HAGT No.1 on trip of SHGT No.1 trip","NCSPS enablement status for HAGT No.1 on trip of SHGT No.2 trip","NCSPS enablement status for LIPM No.1 on trip of LIPM No.2 trip","NCSPS enablement status for PMHA No.1 on trip of PMHA No.2 trip","NCSPS enablement status for PMHA No.1 on trip of PMSH trip","NCSPS enablement status for PMHA No.1 on trip of SHGT No.1 trip","NCSPS enablement status for PMHA No.1 on trip of SHGT No.2 trip","NCSPS enablement status for PMHA No.3 on trip of PMHA No.4 trip","NCSPS enablement status for PMHA No.3 on trip of a Palmerston transformer","NCSPS enablement status for SHGT No.1 on trip of PMSH trip","NCSPS enablement status for SHGT No.1 on trip of SHGT No.2 trip","NSW region","No of Rowville SVC off","North West MW load normally radial from Sheffield (Hampshire, Burnie, Port Latta, Smithton, Emu Bay, Ulverstone, Devonport, Wesley Vale, Railton). Native Load","Number of Bell Bay units 1&2 in service","Number of Cluny generator Units In Service","Number of Lake Echo generator Units In Service","Number of Meadowbank generator Units In Service","Number of Murray 11-14 Syn Cons In Service","Number of Reece units in service","Number of Somerton GT Units In Service","Number of Trevallyn units in service","Number of Tumut 1 Units online (as Generators or Syncons)","Number of Tumut 2 Syn Cons In Service","Number of Tumut 2 Units online (as Generators or Syncons)","Number of Tungatinah generator Units In Service","Number of West Kiewa PS unit in service","Oakey GT unit 2","On status of (01) 330kV line between Stockdill and Upper Tumut","On status of (03) 330kV line between Lower Tumut and Yass ","On status of (8C) 330kV line between Armidale and Dumaresq","On status of (8E) 330kV line between Armidale and Sapphire WF","On status of (8L) 330kV line between Bulli Creek R3 and Dumaresq","On status of (8M) 330kV line between Bulli Creek R3 and Dumaresq","On status of 43 MVAr HF6 capacitor bank at Basslink George Town converter station","On status of Barron Gorge Unit 1","On status of Barron Gorge Unit 2","On status of Braemar SVC","On status of Callide C unit 3","On status of Callide C unit 4","On status of Chalumbin reactor on feeder 857","On status of Farrell - Sheffield #2 220kV line","On status of Fisher PS","On status of Fishermen's Bend Synchronous Condenser","On status of George Town - Sheffield #1 220kV line","On status of George Town - Sheffield #2 220kV line","On status of Gladstone Unit 1","On status of Gladstone Unit 2","On status of Gladstone Unit 3","On status of Gladstone Unit 4","On status of Gladstone Unit 5","On status of Gladstone Unit 6","On status of Gold Coast Contingency load shed block","On status of John Butters PS","On status of Kareeya Unit 1","On status of Kareeya Unit 2","On status of Kareeya Unit 3","On status of Kareeya Unit 4","On status of Lemonthyme PS","On status of Lower Tumut to Murray (66) 330kV line","On status of Lower Tumut to Upper Tumut (64) 330kV line","On status of Mackintosh PS","On status of Meadowbank PS","On status of Millmerran Unit 1","On status of Moorabool to Cressy #1 500kV line reactor","On status of Mt Stuart #2 Generator","On status of Murray to Upper Tumut (65) 330kV line","On status of Pelican Pt GT #11","On status of Pelican Pt GT #12","On status of Pelican Pt Steam Turbine #18","On status of Repulse PS","On status of Rowville SVC 1","On status of Rowville SVC 2","On status of Sheffield - Palmerston 220kV line","On status of South East SVC 1","On status of South East SVC 2","On status of Swanbank E","On status of T50 Inisfail 132kV Cap Bank","On status of T51 Cairns # 2 Cap Bank (132kV)","On status of Tamworth Cap Bank","On status of Tarong Limit Loadshed Block 1","On status of Tarong Limit Loadshed Block 2","On status of Tarong Limit Loadshed Block 3","On status of Templestowe Synchronous condenser 1","On status of Tribute PS","On status of Unit 3 Gordon PS","On status of Unit 3 Gordon PS as a Synchronous Condenser","On status of Wilmot PS","On status of Wivenhoe Pump 1","On status of Wivenhoe Pump 2","On status of the Armidale #1 Cap Bank","On status of the CB on the 220kV R2 Rector (24.2 MVAr) at Buronga","On status of the Chapel St #1 Cap Bank","On status of the Dederang #1 220kV Cap Bank","On status of the Dederang #2 330kV Cap Bank","On status of the Directlink ECS","On status of the HYTS cap bank","On status of the Hampshire CB B152. This radialises the 110kV link from Burnie to Farrell","On status of the Horsham SVC","On status of the Lindisfarne #1 Cap Bank","On status of the Risdon #1 Cap Bank","On status of the Tas Network SPS","On status of the Woodonga 330kV Cap Bank","On status of unit 1 Townsville GT (Yabulu) PS","On/Off status of H2 South Pine #1 110kV Cap Bank","On/Off status of H2 South Pine #2 110kV Cap Bank","On/Off status of H2 South Pine #3 275kV Cap Bank","On/Off status of H2 South Pine #4 275kV Cap Bank","On/Off status of H2 South Pine #5 110kV Cap Bank","On/Off status of H22 Loganlea #4 110kV Cap Bank","On/Off status of H22 Loganlea #5 110kV Cap Bank","On/Off status of H22 Loganlea #7 110kV Cap Bank","On/Off status of H3 Belmont #1 110kV Cap Bank","On/Off status of H3 Belmont #2 110kV Cap Bank","On/Off status of H3 Belmont #3 275kV Cap Bank","On/Off status of H3 Belmont #4 275kV Cap Bank","On/Off status of H3 Belmont #5 110kV Cap Bank","On/Off status of H36 Blackwall #5 275kV Cap Bank","On/Off status of H36 Blackwall #6 275kV Cap Bank","On/Off status of H9 Palmwoods #1 132kV Cap Bank","On/Off status of H9 Palmwoods #2 132kV Cap Bank","On/Off status of H9 Palmwoods #3 275kV Cap Bank","On/Off status of H9 Palmwoods #4 132kV Cap Bank","On/Off status of T155 West Darra #1 110kV Cap Bank","On/Off status of T155 West Darra #2 110kV Cap Bank","On/Off status of T155 West Darra #3 110kV Cap Bank","On/Off status of T24 Runcorn #2 110kV Cap Bank","On/Off status of T30 Ashgrove West #2 110kV Cap Bank","On/Off status of T30 Ashgrove West #3 110kV Cap Bank","On/Off status of Wivenhoe1 unit for either generator or syn con","On/Off status of Wivenhoe2 unit for either generator or syn con","Online staff entered Tarong Tarong-Blackwall Limit emergency offset","Online staff entered Tarong Woolooga-Palmwoods Limit emergency offset","Para - Tailem Bend 275kV line #1 SMVA flow","Para - Tailem Bend 275kV line #2 SMVA flow","Pelican Point CCGT","Pioneer Sugar Mill","Playford (4 aggregated units)","Poatina hydro (units 1 & 2 aggregated)","Power transfer (MW) Millmerran-Middle Ridge fdr 9908 measured at Millmerran, Line end switched MW","Quarantine GT unit 1","Quarantine GT unit 2","Quarantine GT unit 4","Queensland region","Redbank unit 1","Reece hydro unit 1","Reece hydro unit 2","Roma GT unit 7","Roma GT unit 8","Rowallan PS (SCADA)","Rubicon Power Station","SA Metro Capacitors in service","SMVA on Mannum to Mannum Pump 2 132 kV line at Mannum","SMW flow on 967 132kV line at Lismore","Shoalhaven hydro (aggregated Bendeela and Kangaroo Valley units)","Shoalhaven pumps (2 aggregated pumps)","Snowy fully co-optimised constraint offset for CSP/CSC trial","Snowy region","Snuggery - Keith line ON status","Somerton GT (4 aggregated units)","South Australia region","South East - Tailem Bend 275 kV line #1 SMVA flow","South Morang F2 transformer tap number","South Morang to Keilor 500 kV line MW flow, MW flow at SMTS end","Southern TAS MW load. All load south of Palmerston, including industrial loads. Native Load. Sum of South East, SouthernX and Hobart area loads","Stanwell unit 1","Stanwell unit 2","Stanwell unit 4","Starfish Hill WF (MW)","Status of Basslink Frequency controller","Status of Tas Frequency Control SPS","Status of the Gold Coast Directlink ECS summer/winter rating. 1 = summer, 0 = winter","Sum of Murray Generators on the southern buses","Sum of the load on each of the Armidale 330/132 kV transformers","Sum of the load on the 132 kV side on each of the 330/132 kV transformers at Tamworth","Summated Inertia of Callide C PS","Summated Inertia of Gladstone PS","Summated Inertia of Tarong PS","Summated MVAr loading measured at APD 500kV bus","Summated MW flow on 275/110kV Mudgeeraba Transformers 1,3 & 5","Summated MW flow on110kV feeders 757 & 758 measured at Terranora","Summated MW flow on275kV feeders 805 & 806 measured at Swanbank","Summated MW flows for 275kV fdrs 832,837,8812,827,875,8848,8849 meas.at Tar &MRidge","Summated MW flows for 275kV fdrs 879, 8857, 8858 and 132kV fdrs 7128, 7208.","Summated MW flows for 275kv fdrs 845, 834, 821 (flow in Southerly direction)","Summated MW flows on 275kV fdrs 805/2, 805/3 & 805 and 110kV fdr 7283","Summated MW flows on 275kV fdrs 813,814,819 measured at Gin Gin","Summated MW flows on 275kV fdrs 813,814,819,8810 & 8811 measured at GinGn and Tarong","Summated MW flows on 275kV lines 821, 834, 8846, 8847 measured at Nebo and 132kV lines 7124/2 and 7383 measured at Dysart","Summated MW generation of Collinsville","Summated MW generation of Gladstone,Callide A, Callide B, Stanwell, Barcaldine Power Stations","Summated MW generation of Townsville, Mt Stuart, Kareeya, Barron Gorge, Mackay Power Stations","Summated MW loading into APD measured at APD 500kV bus","Summated MW loads at Yass, Wagga, Jindera, Darlington Pt & Broken Hill","Summated inertia of all online Snowy machines (generators, pumps and syncons)","Swanbank B unit 1","Swanbank B unit 2","Swanbank B unit 3","Swanbank B unit 4","Swanbank E GT","Tarong Limit operator entered offset 3","Tarong Limit operator entered offset 4","Tarong option3 calculated operating Limit for ESCA display page and is tracked by option1","Tarong unit 2","Tarong unit 4","Tas FCAS calc for MG for Raise 5 min","Tas FCAS calc for MG for Raise 6 sec","Tas FCAS calc for MG for Raise 60 sec","Tas FCAS calc for Tas max load for Lower 5 min","Tas FCAS calc for Tas max load for Lower 6 sec","Tas FCAS calc for Tas max load for Lower 60 sec","Tas FCAS calc for network event (loss of 2 Comalco potlines) for Lower 5 min","Tas FCAS calc for network event (loss of 2 Comalco potlines) for Lower 6 sec","Tas FCAS calc for network event (loss of 3 Comalco potlines with Bell Bay tripping scheme armed) for Lower 5 min","Tas FCAS calc for network event (loss of 3 Comalco potlines with Bell Bay tripping scheme armed) for Lower 6 sec","Tas FCAS calc for network event (loss of 3 Comalco potlines with Bell Bay tripping scheme armed) for Lower 60 sec","Tas FCAS calc for network event (loss of 3 Comalco potlines) for Lower 5 min","Tas FCAS calc for network event (loss of 3 Comalco potlines) for Lower 6 sec","Tas FCAS calc for network event (loss of 3 Comalco potlines) for Lower 60 sec","Tas FCAS calc for network event (loss of FASH#1 line) for Raise 5 min","Tas FCAS calc for network event (loss of FASH#1 line) for Raise 6 sec","Tas FCAS calc for network event (loss of FASH#1 line) for Raise 60 sec","Tas FCAS calc for network event (loss of FASH#2 line) for Raise 5 min","Tas FCAS calc for network event (loss of FASH#2 line) for Raise 6 sec","Tas FCAS calc for network event (loss of FASH#2 line) for Raise 60 sec","Tas FCAS calc for network event (loss of George Town Transformer) for Raise 5 min","Tas FCAS calc for network event (loss of George Town Transformer) for Raise 6 sec","Tas FCAS calc for network event (loss of George Town Transformer) for Raise 60 sec","Tas FCAS calc for network event (loss of Tungatinah + Lake Echo + Butlers Gorge) for Raise 5 min","Tas FCAS calc for network event (loss of Tungatinah + Lake Echo + Butlers Gorge) for Raise 6 sec","Tas FCAS calc for network event (loss of Tungatinah + Lake Echo + Butlers Gorge) for Raise 60 sec","Tas FCAS calc for network event (loss of a GTBB line) for Raise 5 min","Tas FCAS calc for network event (loss of a GTBB line) for Raise 6 sec","Tas FCAS calc for network event (loss of a GTBB line) for Raise 60 sec","Tas FCAS calc for network event (loss of all Bell Bay units) for Raise 5 min","Tas FCAS calc for network event (loss of all Bell Bay units) for Raise 6 sec","Tas FCAS calc for network event (loss of all Gordon units) for Raise 5 min","Tas FCAS calc for network event (loss of all Gordon units) for Raise 6 sec","Tas FCAS calc for network event (loss of all Gordon units) for Raise 60 sec","Tas Scheduled Gen + Non Scheduled Gen - Basslink Export from TAS. Equal to TAS Native Load","Telemetered MW per minute rate of change up for Barcaldine GT","Telemetered MW per minute rate of change up for Bendeela and Kangaroo PS","Telemetered MW per minute rate of change up for Hume NSW PS","Telemetered MW per minute rate of change up for Hunter GTs","Telemetered MW per minute rate of change up for Mackay GT PS","Telemetered MW per minute rate of change up for unit 1 Callide B PS","Telemetered MW per minute rate of change up for unit 1 Collinsville PS","Telemetered MW per minute rate of change up for unit 1 Gladstone PS","Telemetered MW per minute rate of change up for unit 1 Kareeya PS","Telemetered MW per minute rate of change up for unit 1 Wivenhoe PS","Telemetered MW per minute rate of change up for unit 2 Callide A PS","Telemetered MW per minute rate of change up for unit 2 Collinsville PS","Telemetered MW per minute rate of change up for unit 2 Eraring PS","Telemetered MW per minute rate of change up for unit 2 Gladstone PS","Telemetered MW per minute rate of change up for unit 3 Callide C PS","Telemetered MW per minute rate of change up for unit 3 Collinsville PS","Telemetered MW per minute rate of change up for unit 3 Eraring PS","Telemetered MW per minute rate of change up for unit 3 Gladstone PS","Telemetered MW per minute rate of change up for unit 3 Kareeya PS","Telemetered MW per minute rate of change up for unit 3 Munmorah PS","Telemetered MW per minute rate of change up for unit 3 Swanbank PS","Telemetered MW per minute rate of change up for unit 3 Tarong PS","Telemetered MW per minute rate of change up for unit 4 Bayswater PS","Telemetered MW per minute rate of change up for unit 4 Collinsville PS","Telemetered MW per minute rate of change up for unit 4 Gladstone PS","Telemetered MW per minute rate of change up for unit 4 Swanbank PS","Telemetered MW per minute rate of change up for unit 5 Gladstone PS","Telemetered MW per minute rate of change up for unit 5 Vales Pt PS","Telemetered MW per minute rate of change up for unit 6 Gladstone PS","Telemetered MW per minute rate of change up for unit 6 Vales Pt PS","Telemetered MW per minute rate of change up for unit 7 Wallerawang PS","Telemetered MW per minute rate of change up for unit 8 Wallerawang PS","Telemetered maximum MW for Bendeela and Kangaroo PS","Telemetered maximum MW for Hume NSW PS","Telemetered maximum MW for Hunter GTs","Telemetered maximum MW for unit 1 Bayswater PS","Telemetered maximum MW for unit 1 Eraring PS","Telemetered maximum MW for unit 1 Redbank PS","Telemetered maximum MW for unit 3 Eraring PS","Telemetered maximum MW for unit 3 Liddell PS","Telemetered maximum MW for unit 4 Bayswater PS","Telemetered maximum MW for unit 4 Eraring PS","Telemetered maximum MW for unit 4 Liddell PS","Telemetered maximum MW for unit 5 Vales Pt PS","Telemetered maximum MW for unit 6 Vales Pt PS","Telemetered maximum MW for unit 7 Wallerawang PS","Telemetered maximum MW for unit 8 Wallerawang PS","Telemetered minimum MW for Barcaldine GT","Telemetered minimum MW for Swanbank E GT PS","Telemetered minimum MW for Tarong North PS","Telemetered minimum MW for unit 1 Collinsville PS","Telemetered minimum MW for unit 1 Gladstone PS","Telemetered minimum MW for unit 1 Millmerran PS","Telemetered minimum MW for unit 1 Mt. Stuart GT PS","Telemetered minimum MW for unit 1 Oakey GT PS","Telemetered minimum MW for unit 1 Roma GT PS","Telemetered minimum MW for unit 1 Stanwell PS","Telemetered minimum MW for unit 1 Swanbank B PS","Telemetered minimum MW for unit 1 Tarong PS","Telemetered minimum MW for unit 1 Townsville GT (Yabulu) PS","Telemetered minimum MW for unit 1 Wivenhoe PS","Telemetered minimum MW for unit 2 Barron Gorge PS","Telemetered minimum MW for unit 2 Callide A PS","Telemetered minimum MW for unit 2 Callide B PS","Telemetered minimum MW for unit 2 Gladstone PS","Telemetered minimum MW for unit 2 Kareeya PS","Telemetered minimum MW for unit 2 Millmerran PS","Telemetered minimum MW for unit 2 Mt. Stuart GT PS","Telemetered minimum MW for unit 2 Oakey GT PS","Telemetered minimum MW for unit 2 Roma GT PS","Telemetered minimum MW for unit 2 Stanwell PS","Telemetered minimum MW for unit 2 Swanbank B PS","Telemetered minimum MW for unit 2 Tarong PS","Telemetered minimum MW for unit 3 Collinsville PS","Telemetered minimum MW for unit 3 Gladstone PS","Telemetered minimum MW for unit 3 Stanwell PS","Telemetered minimum MW for unit 3 Swanbank B PS","Telemetered minimum MW for unit 3 Tarong PS","Telemetered minimum MW for unit 4 Callide A PS","Telemetered minimum MW for unit 4 Collinsville PS","Telemetered minimum MW for unit 4 Gladstone PS","Telemetered minimum MW for unit 4 Kareeya PS","Telemetered minimum MW for unit 4 Stanwell PS","Telemetered minimum MW for unit 4 Swanbank B PS","Telemetered minimum MW for unit 4 Tarong PS","Telemetered minimum MW for unit 5 Collinsville PS","Telemetered minimum MW for unit 5 Gladstone PS","Telemetered minimum MW for unit 6 Gladstone PS","Torrens Island A unit 1","Torrens Island A unit 2","Torrens Island A unit 3","Torrens Island B unit 1","Torrens Island B unit 2","Torrens Island B unit 3","Total 66 kV & 22 kV MW load at Wodonga. Includes output of Hume Power Station on VIC side","Total SCADA MW for Woolnorth Windfarm - Combined output of Bluff Point & Studland Bay wind farms","Townsville GT (Yabulu) unit 2","Trevallyn hydro (4 aggregated units)","Unit 1 Broken Hill GT PS (SCADA)","Unit 1 Callide A PS","Unit 1 Gordon PS (SCADA)","Unit 2 Gordon PS (SCADA)","Unit 3 Callide A PS","Unit 3 Gordon PS (SCADA)","Unit 5 Kareeya PS (SCADA)","Vales Pt unit 5","Vales Pt unit 6","Valley Power GT (6 aggregated units)","Vic largest unit output MW","Victoria region","Voltage on the Armidale #5 132kV bus","Voltage on the H24 Calvale 275kV bus","Voltage on the H7 Gladstone 275kV bus","Voltage on the Liddell Gen Bus","Wagga area caps o.o.s. MVAR","Wallerawang unit 8","Warragamba MW Output","Wattle Point windfarm generation MW","Wattle Pt WF (MW)","West Coast MW load normally radial from Farrell (Rosebery, Queenstown, Newton, Que, Savage River). Native Load","West Kiewa hydro (Units 1, 2, 3 and 4 aggregated)","West Kiewa hydro (units 3 & 4 aggregated)","Wivenhoe hydro unit 2","Woolnorth wind farm","Yallourn W unit 1","Yallourn W unit 2","Yallourn W unit 3","Yallourn W unit 4","Yallourn unit 1 status (=1 in 220kV mode, =0 otherwise)","Yallourn unit 1 status (=1 in 500kV mode, =0 otherwise)","Yambuk Wind Farm"]},"GROUPING_ID":{"sql_type":"VARCHAR(20)","pl_type":"str","mandatory":false,"comment":"The Grouping associated with the SPD ID - most often a RegionID","examples":["NEMMCO","NSW1","QLD1","SA1","SNOWY1","TAS1","VIC1","Z_ARCHIVE"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2006/05/25 10:11:34"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23EMSMASTER%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":127727,"decompressed_size_all_time":133522910},"visibility":"Public"},"FCAS_REGU_USAGE_FACTORS":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"FCASREGUSEFACTORS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#25"],"comment":"Stores the proportion of enabled regulation FCAS dispatch that is typically consumed for frequency regulation. Used to calculate the projected state of charge for energy storage systems.","primary_keys":["BIDTYPE","EFFECTIVEDATE","PERIODID","REGIONID","VERSIONNO"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"The type of regulation FCAS service [RAISEREG,LOWERREG]","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date for this regulation FCAS usage factor","examples":["2024/02/29 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID (1 - 48) within the calendar day to which this usage factor applies","examples":["1","48"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version with respect to effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last time the data has been changed/updated","examples":["2024/03/04 10:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"USAGE_FACTOR":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The proportion of cleared regulation FCAS that is assumed to be used within a dispatch interval. Expressed as a fractional amount between 0 and 1","examples":["0.01","0.33"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FCAS_REGU_USAGE_FACTORS%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":7},"compressed_size_per_month":2376,"decompressed_size_all_time":570090},"visibility":"Public","trigger":"Updates whenever FCAS_REGU_USAGE_FACTORS data is updated"},"FCAS_REGU_USAGE_FACTORS_TRK":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"FCASREGUSEFACTORS_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#31"],"comment":"Stores the proportion of enabled regulation FCAS dispatch that is typically consumed for frequency regulation. Used to calculate the projected state of charge for energy storage systems.","primary_keys":["EFFECTIVEDATE","VERSIONNO"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date for this regulation FCAS usage factor","examples":["2024/02/29 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of the date with respect to effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date time that this set of usage factors was authorised","examples":["2024/03/04 10:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last time the data has been changed/updated","examples":["2024/03/04 10:00:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FCAS_REGU_USAGE_FACTORS_TRK%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":7},"compressed_size_per_month":451,"decompressed_size_all_time":108180},"visibility":"Public","trigger":"Updates whenever FCAS_REGU_USAGE_FACTORS data is updated"},"FORCEMAJEURE":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#467"],"comment":"FORCEMAJEURE used to set out the start and end dates / periods of any force majeure event. FORCEMAJEURE is not used.","description":"FORCEMAJEURE is a public table, and is available to all participants.\n\nSource\n\nFORCEMAJEURE is not used; was updated if a force majeure event was\nrecorded.","unused":true,"primary_keys":["FMID"],"indexes":[["LASTCHANGED"]],"columns":{"FMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Force Majeure Identifier"},"APCSTARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"APC Start Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising end of event"},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"End Date for this event","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"End Trading Interval for this event","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising start"},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Start Date for this event","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Start Trading Interval for event","is_integer":true,"num_int_bits":16}},"visibility":"Public","trigger":"When force majeure event is recorded"},"FORCEMAJEUREREGION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#476"],"comment":"FORCEMAJEUREREGION used to set out regions impacted by a force majeure event. This table is not used.","description":"FORCEMAJEUREREGION is public data, and is available to all participants.\n\nSource\n\nFORCEMAJEUREREGION is not used; was updated if a force majeure event was\nrecorded.","unused":true,"primary_keys":["FMID","REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"FMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Force Majeure ID"},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"When force majeure event is recorded"},"FPP_CONSTRAINT_FREQ_MEASURE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"CONSTRAINT_FREQ_MEASURE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#1"],"comment":"This report delivers the weighted 4 second frequency measure data for each constraint","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","MEASUREMENT_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MEASUREMENT_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the SCADA data (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:00:04"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CORRELATION_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate the result of the Frequency Measure correlation check between regions in the same constraint. Supported values are: 0 = Frequency measures in this constraint are not correlated (e.g. system separation between two regions) 1 = Frequency measures in this constraint are correlated","examples":["0"],"is_boolean":true},"FM_LOWER_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated 4 second Frequency Measure in Hz for that constraint from the FPP database. Frequency Measure data is split across these two raise and lower columns in the following ways: >0 = Allocated to the FM_RAISE_HZ column <0 = Allocated to the FM_LOWER_HZ column 0 = To fill any gaps where the alternative column is not applicable (or no deviation from 50 Hz)","examples":["-0.00005132","0","-0.02822295"],"is_float":true},"FM_RAISE_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated 4 second Frequency Measure in Hz for that constraint from the FPP database. Frequency Measure data is split across these two raise and lower columns in the following ways: >0 = Allocated to the FM_RAISE_HZ column <0 = Allocated to the FM_LOWER_HZ column 0 = To fill any gaps where the alternative column is not applicable (or no deviation from 50 Hz)","examples":["0.00000727","0","0.04382655"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"USED_IN_RCR_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate the result of the Frequency Measure alignment check between Mainland and Tasmania for global constraints. Supported values are: 0 = Not used in RCR calculation as the signs for the frequency measures between Mainland and Tasmania do not align 1 = Used in the RCR calculation as the signs for the frequency measures between Mainland and Tasmania do align in the case of global constraints. For non-global constraints this flag is set to 1","examples":["1"],"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_CONSTRAINT_FREQ_MEASURE%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17641116,"decompressed_size_all_time":39302053980},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes): At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_CONTRIBUTION_FACTOR":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"CONTRIBUTION_FACTOR","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#7"],"comment":"This report delivers the calculated contribution factor value for each 5 minute trading interval for each constraint and FPP unit","primary_keys":["CONSTRAINTID","FPP_UNITID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID/ TNI)","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD_LOAD","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BOYNE_LOAD","BOYNE_QBOL_D","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TOMAGO_LOAD","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising contribution factors (CF) where a units performance is negative. For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["2.76377","0","597.15514"],"is_float":true},"CF_ABS_POSITIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute positive performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising contribution factors (CF) where a units performance is positive. For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["1.41659","0","590.56978"],"is_float":true},"CF_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the contribution factor (CF) Supported values are: 0 = CF is calculated based on good input data 1 = CF is 0 because it is not primary in the group 2 = CF is not for the DUID but for the whole group 4 = CF is calculated based on substitute performance 8 = CF is 0 because FM is unreliable. 16 = CF is 0 because more than 50 percent input is bad or not available.","examples":["0","1","32"],"is_integer":true,"num_int_bits":32},"CONTRIBUTION_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Contribution Factor (the calculated contribution factor for the FPP unit and constraint ID for that trading interval) - for further details please see the FPP procedure document","examples":["-0.00000677","0.00000102","0","0.62437967"],"is_float":true,"col_name_also_metadata":true},"DEFAULT_CONTRIBUTION_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Default Contribution Factor (the calculated default contribution factor based on historical performance for the FPP unit and constraint ID for that trading interval) that is effective for this trading interval, which joins back to FPP_FORECAST_DEFAULT_CF - for further details please see the FPP procedure document","examples":["-0.00000003","0","-0.12903896"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NCF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising negative contribution factors (NCF). For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable 0 = When NCF is zero (i.e. CF is positive), then this total will be represented as zero","examples":["2.76377","0","597.16219"],"is_float":true},"NEGATIVE_CONTRIBUTION_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Negative Contribution Factor (the calculated negative contribution factor for the FPP unit and constraint ID for that trading interval) - for further details please see the FPP procedure document","examples":["-0.00000677","0","-0.44490562"],"is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","examples":["AGLLBESS","AGLWBESS","ALCOAPA","ALDOGASF","ALNTARES","ALNTBHWF","ARARATWF","B2PS","BALBESS","BANGOWF2","BBPEM","BERBANK","BERBANKW","BERYBKWF","BLYTHBAT","BOCOROCK","BODWF1","BOMENSF","BORAL","BOULBESS","BRNDBESS","BULGANA","BUNGALA1","BUNGALA2","BUNGBESS","BUSF","BWFTRUST","CAPBESS","CAPEBYRN","CAPRISF","CAPTPL","CARWARP","CATHROCK","CGBESS","CHALLHWF","CHERRYWF","CLARESF1","CLEANCO","CLEMGPWF","CLERMSF","CNUNDAWF","COLEAMSF","COLLECWF","COLUMSF","COOPGWF","COROWASF","CPEMGEN","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CULLRGWF","CUSF","DALRYMPN","DARLSF","DAYDSF","DDSF","DELTA","DIAMDGEN","DIAMOND","DPNTBESS","DULACCA","DUNDWF","ECOGEN","EDENVALE","EDISON","EDLCSMQ","EEQGEN","EEQLILY","EEQMEWF","ENELAUS","EPVIC1","EQMREHA1","EQMREHA2","ERMPOWER","FINLEYSF","FRVROYAL","FSNSW","GANNBESS","GANNSF","GBATEAST","GESF","GLENROSF","GLENSF","GOON","GPWF1","GPWF2","GRANHAWF","GRIFFITH","GSPOWER","GSWF1A","GSWF1B","GUNNEDAH","GUNNING","GUNSYND","HALLETT","HAMISF","HAUGHTSF","HAWKES","HAYMSF","HBESS","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HUGSF","HWF3","HYDROTAS","JUNEESF","KARSF","KENNEDYE","KERANGSP","KIATAPRJ","KIDSPHES","KINGARSF","KOORBESS","KSFPROJT","LALLALWF","LANCASF","LIGHTSRC","LIMBESS","LIMONSF","LINGAPWF","LKBWFBES","LKBWIND","LOYYANGA","LVES","MACINTYR","MACQGEN","MANILDRA","MANNUMB","MANNUMS2","MBAHNTH","METPL","METZSF","MOKOANSF","MOLONGOP","MONDO","MOORAWF","MOREEAC","MORTLSWF","MOUSF","MRNBESS","MTGELLWF","MTMERCER","MTMILLAR","MUGGALSP","MULWALSF","MUNCRKSF","MUWARRA2","MWARRA","NESBESS","NEWENGSF","NEWGEN","NEWGRWF","NPSAIL","NUMURKSF","NVTSF","OEBESS","OERARING","ORANBESS","PEAKCO","PLBESS1","PORTADL","PSF","PYRENEES","QGCSALE1","QUORNPSF","RANGBESS","RATCHTOW","RIVEBESS","ROSSRVER","RYAN","RYEPARK","SALTCRK","SAPHWF1","SAWCML","SEBSF","SECGEN","SHELLNEW","SITHE","SLVRTN","SMCTSV","SMFBESS","SMTHBESS","SNODE1","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SOUTHHYD","SOUTHYD2","SRSF1","STANCCWF","STANRET","STANWAM1","STANWAM2","STANWELL","STARFISH","STOCKYRD","STUBB1SF","SUNRSF","SUNSPOT3","SUNTOP","TAILEM","TALL","TARALGA","TBSF","TELSTRAE","TIPSCO","TLTSFS","TOMAGOAC","TRANSGBH","TRGBESS","TRUDW","ULPBESS1","UNIQLDSF","VBBHMCA3","WAGGAOPS","WALGBESS","WANDOAN","WATERLWF","WDOWBESS","WDOWNS","WELLNTH","WEMENSF","WGWF","WHECKSON","WILDCATL","WILLBESS","WINTONSF","WLWLSF1","WLWLSF2","WOLLARSF","WOODLAWN","WOOLBESS","WOOLNWF","WOOLOOGA","WROCKWF","WSUNDAY","WTAHBESS","WYALONG","WYASF","XELIO","YALLOURN","YALSTHWF","YARRANSF","YARWUN","YATSF","YESSA","ZENENGEN"],"is_categorical":true},"SETTLEMENTS_UNITID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"The Settlements Unit ID (registered DUID / TNI) Note that this SETTLEMENTS_UNITID is what is sent and used by the Settlements system, and may be different from the FPP_UNITID for non-scheduled loads where the FPP_UNITID may be a descriptive key, whereas what will be sent to Settlements as the SETTLEMENTS_UNITID will be the TNI code.","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NTMG","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBOH","QBOL","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VAPD","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_CONTRIBUTION_FACTOR%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":4,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":153150844,"decompressed_size_all_time":274778010150},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns CONTRIBUTION_FACTOR. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"The private report will be delivered at the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)The public report is delivered the next market day (at 4 am)"},"FPP_EST_COST":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"EST_COST","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#13"],"comment":"This report delivers the estimated cost for each FPP unit for each constraint for each 5 minute trading interval","primary_keys":["CONSTRAINTID","FPP_UNITID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","is_categorical":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID / TNI)"},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the FPP run number from the FPP database, however there are some cases (like a new pricing run of the constraint FCAS processor received by the FPP system) where the version number listed here will be the financial estimate run number from the FPP database (this number is a different sequence from the FPP run number because there is no recalculation of performance or contribution, just changes to pricing / p regulation hence only the financial estimation is performed).","is_integer":true,"unsigned_int":true,"num_int_bits":64},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"FPP in AUD (the financial estimate of frequency performance payment calculated for the constraint / bid type / unit). This value can be either positive (credit) or negative (debit). For details on the calculation, please see FPP procedure and supporting documentation.","is_float":true,"col_name_also_metadata":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","is_categorical":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)"},"UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Unused recovery FCAS in AUD (the financial estimate of the recovery of unused FCAS calculated for the constraint / bid type / unit). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","is_float":true},"USED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Used recovery FCAS in AUD (the financial estimate of the recovery of used FCAS calculated for the constraint / bid type / unit). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","is_float":true}},"visibility":"Private","warnings":[{"msg":"The REPORT_NAME metadata column has the same column name as an actual columns FPP. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_EST_PERF_COST_RATE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"EST_PERF_COST_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#19"],"comment":"This report delivers the estimated performance cost rate for each constraint for each 5 minute trading interval","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the FPP run number from the FPP database, however there are some cases (like a new pricing run of the constraint FCAS processor received by the FPP system) where the version number listed here will be the financial estimate run number from the FPP database (this number is a different sequence from the FPP run number because there is no recalculation of performance or contribution, just changes to pricing / p regulation hence only the financial estimation is performed).","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_PAYMENT_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The payment rate for FPP in AUD / MWHz (the denominator used is the sum of positive performance for the constraint calculated by contribution factor calculation). This value will be either 0 (nil), or a positive value (credit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["0.00045946","0","415.8802313"],"is_float":true},"FPP_RECOVERY_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The recovery rate for FPP in AUD / MWHz (the denominator used is the absolute sum of negative performance for the constraint calculated by the contribution factor calculation). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["0.00045607","0","180.3317011"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:25"],"parse_csv_as_string":true,"is_s_datetime":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)","examples":["NSW1,QLD1,SA1,TAS1,VIC1","NSW1,QLD1,SA1,VIC1","TAS1"]},"UNUSED_FCAS_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The rate for unused FCAS in AUD / MWHz (the denominator used is the absolute sum of negative performance for the constraint calculated by the default contribution factor calculation). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["0.00000178","0","24.67699433"],"is_float":true},"USED_FCAS_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The rate for used FCAS in AUD / MWHz (the denominator used is the absolute sum of negative performance for the constraint calculated by the negative contribution factor calculation). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["0.0000086","0","57.33851748"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_EST_PERF_COST_RATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":816591,"decompressed_size_all_time":1691791560},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_EST_RESIDUAL_COST_RATE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"EST_RESIDUAL_COST_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#25"],"comment":"This report delivers the estimated residual cost rate for each constraint for each 5 minute trading interval","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the FPP run number from the FPP database, however there are some cases (like a new pricing run of the constraint FCAS processor received by the FPP system) where the version number listed here will be the financial estimate run number from the FPP database (this number is a different sequence from the FPP run number because there is no recalculation of performance or contribution, just changes to pricing / p regulation hence only the financial estimation is performed).","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"FPP in AUD/MWh (the financial estimate of frequency performance payment calculated). This value can be either positive (credit) or negative (debit). For details on the calculation, please see FPP procedure and supporting documentation.","examples":["-0.0000019","0.00000221","0","0.60282409"],"is_float":true,"col_name_also_metadata":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:25"],"parse_csv_as_string":true,"is_s_datetime":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)","examples":["NSW1,QLD1,SA1,TAS1,VIC1","NSW1,QLD1,SA1,VIC1","TAS1"]},"UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Unused recovery FCAS in AUD/MWh (the financial estimate of the recovery of unused FCAS calculated). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["-0.00000014","0","-2.60891348"],"is_float":true},"USED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Used recovery FCAS in AUD/MWh (the financial estimate of the recovery of used FCAS calculated). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation.","examples":["-0.00000002","0","-0.38256636"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_EST_RESIDUAL_COST_RATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":580355,"decompressed_size_all_time":1182843030},"visibility":"Public","warnings":[{"msg":"The REPORT_NAME metadata column has the same column name as an actual columns FPP. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_FCAS_SUMMARY":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FCAS_SUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#31"],"comment":"This report delivers a summary of FCAS requirements as used by the FPP calculation (i.e. only RAISEREG / LOWERREG bid types)","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNNO","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the dispatch case that was the trigger for the constraint FCAS processor execution","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The dispatch case run number that was the trigger for the constraint FCAS processor execution","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the FPP run number from the FPP database, however there are some cases (like a new pricing run of the constraint FCAS processor received by the FPP system) where the version number listed here will be the financial estimate run number from the FPP database (this number is a different sequence from the FPP run number because there is no recalculation of performance or contribution, just changes to pricing / p regulation hence only the financial estimation is performed).","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Base cost in AUD related to the constraint (from FCAS data used for FPP calculations)","examples":["0.26666667","2","400.97820833","51"],"is_float":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations, i.e. RAISEREG or LOWERREG)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINT_MARGINAL_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal value in AUD/MW per hour related to the constraint (from FCAS data used for FPP calculations)","examples":["0.01","1","96.23477","232000"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:25"],"parse_csv_as_string":true,"is_s_datetime":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"P regulation value in AUD/MW per hour related to the constraint (from FCAS data used for FPP calculations also known as adjusted marginal value)","examples":["0.01","1","96.23477","50"],"is_float":true},"RCR":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RCR MW (the calculated requirement for corrective response from FPP database). Note that this is a join back to the FPP_RCR table.","examples":["7.03881","0","1133.91928"],"is_float":true},"REGULATION_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabled regulation MW used in the FPP calculation (from FPP database)","examples":["160.00001","0","40","338"],"is_float":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)","examples":["NSW1,QLD1,SA1,TAS1,VIC1","NSW1,QLD1,SA1,VIC1","TAS1"]},"TOTAL_FPP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total amount of FPP in AUD changing hands related to the constraint (note that this is not the sum of FPP)","examples":["0.15461008","0","919.60529866"],"is_float":true},"TSFCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"TSFCAS in AUD related to the constraint (FCAS recovery amount related to the constraint also known as adjusted cost)","examples":["0.13341667","2","400.97820833","51"],"is_float":true},"USAGE_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage (calculation of the proportion of regulation FCAS that was calculated to be used). Note that this is a join back to the FPP_USAGE table.","examples":["0.0007998","0","1","0.99992818"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_FCAS_SUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":847268,"decompressed_size_all_time":1987494260},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_FORECAST_DEFAULT_CF":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FORECAST_DEFAULT_CF","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#37"],"comment":"This report delivers the forecast default contribution factors (DCF) effective for a billing period (aligned to the settlement week)","primary_keys":["CONSTRAINTID","EFFECTIVE_END_DATETIME","EFFECTIVE_START_DATETIME","FPP_UNITID","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+ML_L5_APD_LD","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_I+TTS_TG_R5","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++NIL_MG_R5","F_MAIN++RREG_0220","F_MAIN+APD_TL_L5","F_MAIN+LREG_0210","F_MAIN+NIL_MG_R5","F_MAIN+RREG_0220","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"EFFECTIVE_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this default contribution factor related to the combination of FPP unit ID / constraint. This is the billing period over which these default contribution factors will be effective / applied. Effective end date will align with the end of a settlement week.","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVE_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this default contribution factor related to the combination of FPP unit ID / constraint. This is the billing period over which these default contribution factors will be effective / applied. In most cases this will align to the settlement week, however there are some cases (like a new constraint) where the effective start date will be prorated to align with the change.","examples":["2026/09/09 17:55:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID/ TNI)","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD_LOAD","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BBATTERY1","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BOYNE_LOAD","BOYNE_QBOL_D","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","RESS1","RIVNB2","ROMA_7","ROMA_8","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TOMAGO_LOAD","TORRB2","TORRB3","TORRB4","TRGBESS1","TUMUT3","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the historical performance calculation run number from the FPP database (which is different from the FPP run number), however there are some cases (like a new constraint) where the version number listed here will be the FPP run number from the FPP database (this will be where the effective start date time will be prorated to align with the detection of this change).","examples":["1","130"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DCF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint (raise or lower). This is used as the denominator in normalising default contribution factors (DCF) as the historical performance is always negative for DCF. For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["255.05571","428.31788"],"is_float":true},"DCF_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the default contribution factor (DCF)","examples":["0","1","4"],"is_integer":true,"num_int_bits":32},"DEFAULT_CONTRIBUTION_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated default contribution factor from the historical performance period. For further details please see the FPP procedure document.","examples":["-0.00000013","0","-0.03972986"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/09 17:59:02"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region ID of the frequency deviation / frequency measure","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTS_UNITID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"The Settlements Unit ID (registered DUID / TNI) Note that this SETTLEMENTS_UNITID is what is sent and used by the Settlements system, and may be different from the FPP_UNITID for non-scheduled loads where the FPP_UNITID may be a descriptive key, whereas what will be sent to Settlements as the SETTLEMENTS_UNITID will be the TNI code.","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BBATTERY1","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NTMG","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBOH","QBOL","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","RESS1","RIVNB2","ROMA_7","ROMA_8","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TRGBESS1","TUMUT3","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VAPD","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_FORECAST_DEFAULT_CF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":378035,"decompressed_size_all_time":1117384890},"visibility":"Public","trigger":"Approval of an FPP historical default contribution factor calculation run (i.e. every week)"},"FPP_FORECAST_RESIDUAL_DCF":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FORECAST_RESIDUAL_DCF","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#43"],"comment":"This report delivers the forecast residual default contribution factors (DCF) effective for a billing period (aligned to the settlement week)","primary_keys":["CONSTRAINTID","EFFECTIVE_END_DATETIME","EFFECTIVE_START_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+BIP_ML_L5","F_I+GFT_TG_R5","F_I+LREG_0210","F_I+ML_L5_APD","F_I+ML_L5_APD_LD","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+NIL_MREH_TL_L5","F_I+RREG_0220","F_I+TTS_TG_R5","F_MAIN++APD_TL_L5","F_MAIN++BIP_ML_L5","F_MAIN++GFT_TG_R5","F_MAIN++LREG_0210","F_MAIN++ML_L5_APD","F_MAIN++NIL_MG_R5","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R5","F_MAIN+APD_TL_L5","F_MAIN+BIP_ML_L5","F_MAIN+GFT_TG_R5","F_MAIN+LREG_0210","F_MAIN+ML_L5_APD","F_MAIN+ML_L5_APD_LD","F_MAIN+MREH_TL_L5","F_MAIN+NIL_MG_R5","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R5","F_T++CSGO_TG_R5","F_T++NIL_ML_L5","F_T++NIL_ML_RECL_L5","F_T+LREG_0050","F_T+NIL_ML_L5","F_T+NIL_ML_RECL_L5","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"EFFECTIVE_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this residual default contribution factor related to the constraint. This is the billing period over which these default contribution factors will be effective / applied. Effective end date will align with the end of a settlement week.","examples":["2025/01/19 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVE_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this residual default contribution factor related to the constraint. This is the billing period over which these default contribution factors will be effective / applied. In most cases this will align to the settlement week, however there are some cases (like a new constraint) where the effective start date will be prorated to align with the change.","examples":["2025/01/12 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"The version number. In most cases this version will be the historical performance calculation run number from the FPP database (which is different from the FPP run number), however there are some cases (like a new constraint) where the version number listed here will be the FPP run number from the FPP database (this will be where the effective start date time will be prorated to align with the detection of this change).","examples":["1","127"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DCF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint (raise or lower). This is used as the denominator in normalising default contribution factors (DCF). For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["7.92472","825.76042"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/05/16 18:06:11"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUAL_DCF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated residual default contribution factor from the historical performance period. For further details please see the FPP procedure document.","examples":["-0.01986441","-0.72109913"],"is_float":true},"RESIDUAL_DCF_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Boolean","mandatory":false,"comment":"The reason flag showing the decision matrix for the residual default contribution factor (DCF)","examples":["0"],"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_FORECAST_RESIDUAL_DCF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":41957,"decompressed_size_all_time":4340510},"visibility":"Public","trigger":"Approval of an FPP historical default contribution factor calculation run (i.e. every week)"},"FPP_HIST_PERFORMANCE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"HIST_PERFORMANCE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#49"],"comment":"This report delivers the historical performance calculated based on a historical period and effective for a billing period (aligned to the settlement week)","primary_keys":["EFFECTIVE_END_DATETIME","EFFECTIVE_START_DATETIME","FPP_UNITID","VERSIONNO"],"columns":{"EFFECTIVE_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this historical performance values related to the FPP unit ID. This is the billing period over which these historical performance values will be effective / applied over. This will align to the settlement week.","examples":["2025/07/20 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVE_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this historical performance values related to the FPP unit ID. This is the billing period over which these historical performance values will be effective / applied over. This will align to the settlement week.","examples":["2025/07/13 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID/ TNI)","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD_LOAD","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BOYNE_LOAD","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LBB1","LDBESS1","LEM_WIL","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TOMAGO_LOAD","TORRB1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WKIEWA2","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"Version (FPP historical performance calculation run number from the FPP database) Note that due to the these historical calculations, the version numbers listed here are different to the normal FPP run number version for trading interval calculations.","examples":["35","124"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"FPP_HIST_LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated FPP historical lower performance from the historical performance period (substitute lower performance calculated used for negative contribution factor calculation when live performance is unavailable) - please see the NER and FPP procedure documents for further information","examples":["-0.00003","0","-4.41147"],"is_float":true},"FPP_HIST_RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated FPP historical raise performance from the historical performance period (substitute raise performance calculated used for negative contribution factor calculation when live performance is unavailable) - please see the NER and FPP procedure documents for further information","examples":["-0.00001","0","-6.18677"],"is_float":true},"HIST_PERIOD_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Historical period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the historical period for this historical performance calculation related to the FPP unit ID. This is the historical period of trading intervals that feed into the historical performance calculation. This will align to the settlement week.","examples":["2025/06/29 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"HIST_PERIOD_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Historical period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the historical period for this historical performance calculation related to the FPP unit ID. This is the historical period of trading intervals that feed into the historical performance calculation. This will align to the settlement week.","examples":["2025/06/22 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/07/25 18:09:05"],"parse_csv_as_string":true,"is_s_datetime":true},"REG_HIST_LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated regulation historical lower performance from the historical performance period (substitute lower performance when live performance is unavailable and default lower performance used for default contribution factor calculation) - please see the NER and FPP procedure documents for further information","examples":["-0.00001","0","-5.20647"],"is_float":true},"REG_HIST_RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated regulation historical raise performance from the historical performance period (substitute raise performance when live performance is unavailable and default raise performance used for default contribution factor calculation) - please see the NER and FPP procedure documents for further information","examples":["-0.00001","0","-7.91599"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_HIST_PERFORMANCE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":719129,"decompressed_size_all_time":80515030},"visibility":"Public","trigger":"Approval of an FPP historical performance calculation run (i.e. every week)"},"FPP_HIST_REGION_PERFORMANCE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"HIST_REGION_PERFORMANCE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#55"],"comment":"This report delivers the historical region performance calculated based on a historical period and effective for a billing period (aligned to the settlement week). This calculated historical region performance calculation is an input into the constraint level residual default contribution factor (DCF) which is published in FPP_FORECAST_RESIDUAL_DCF","primary_keys":["EFFECTIVE_END_DATETIME","EFFECTIVE_START_DATETIME","REGIONID","VERSIONNO"],"columns":{"EFFECTIVE_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this historical performance values related to the region ID. This is the billing period over which these historical performance values will be effective / applied over. This will align to the settlement week.","examples":["2025/05/18 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVE_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the effective period for this historical performance values related to the region ID. This is the billing period over which these historical performance values will be effective / applied over. This will align to the settlement week.","examples":["2025/05/11 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID of the historical region performance","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(10)","pl_type":"pl.UInt64","mandatory":true,"comment":"Version (FPP historical performance calculation run number from the FPP database) Note that due to the these historical calculations, the version numbers listed here are different to the normal FPP run number version for trading interval calculations.","examples":["25","134"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"FPP_HIST_LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated FPP historical lower performance from the historical performance period (substitute lower performance calculated used for negative contribution factor calculation when live performance is unavailable) - please see the NER and FPP procedure documents for further information","examples":["-0.13998","0","-49.19745"],"is_float":true},"FPP_HIST_RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated FPP historical raise performance from the historical performance period (substitute raise performance calculated used for negative contribution factor calculation when live performance is unavailable) - please see the NER and FPP procedure documents for further information","examples":["-0.03196","0","-61.90924"],"is_float":true},"HIST_PERIOD_END_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Historical period end date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the historical period for this historical performance calculation related to the region ID. This is the historical period of trading intervals that feed into the historical performance calculation. This will align to the settlement week.","examples":["2025/04/27 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"HIST_PERIOD_START_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Historical period start date and time (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) of the historical period for this historical performance calculation related to the region ID. This is the historical period of trading intervals that feed into the historical performance calculation. This will align to the settlement week.","examples":["2025/04/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/05/16 18:06:11"],"parse_csv_as_string":true,"is_s_datetime":true},"REG_HIST_LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated regulation historical lower performance from the historical performance period (substitute lower performance when live performance is unavailable and default lower performance used for default contribution factor calculation) - please see the NER and FPP procedure documents for further information","examples":["-2.77757","-60.9105"],"is_float":true},"REG_HIST_RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated regulation historical raise performance from the historical performance period (substitute raise performance when live performance is unavailable and default raise performance used for default contribution factor calculation) - please see the NER and FPP procedure documents for further information","examples":["-0.32772","-67.26472"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_HIST_REGION_PERFORMANCE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2025,"month":4},"last_month":{"year":2026,"month":9},"compressed_size_per_month":10885,"decompressed_size_all_time":1030800},"visibility":"Public","trigger":"Approval of an FPP historical performance calculation run (i.e. every week)"},"FPP_P5_FWD_EST_COST":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"P5_FWD_EST_COST","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#61"],"comment":"This report delivers the forward estimated unit cost based on P5min runs. These high-level estimates (i.e. assuming that all is unused FCAS) will be provided for each constraint for each 5 minute pre-dispatch interval.","primary_keys":["CONSTRAINTID","FPP_UNITID","INTERVAL_DATETIME","RUN_DATETIME","RUNNO","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","is_categorical":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID / TNI)"},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 5 minute predispatch case that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis of these forward estimates)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 5 minute predispatch case run number that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis for these forward estimates)","is_integer":true,"unsigned_int":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The version number of the effective default contribution factor for the unit / constraint combination taken from the FPP_FORECAST_DEFAULT_CF table","is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EST_UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated unused recovery FCAS in AUD (the forward financial estimate of the recovery of unused FCAS, assuming that all is unused FCAS). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation. Please note that there may be cases where there is not yet a default contribution factor for the constraint (for example if there is a new constraint binding in p5min that has not yet bound in dispatch). In these scenarios there will be no EST_UNUSED_FCAS row sent for the constraint, as it is currently incalculable until a corresponding default contribution factor is calculated from a dispatch run with this constraint binding.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","is_categorical":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)"}},"visibility":"Private","trigger":"At the completion of a P5MIN estimation calculation run (i.e. every 5 mins)"},"FPP_P5_FWD_EST_RESIDUALRATE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"P5_FWD_EST_RESIDUALRATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#67"],"comment":"This report delivers the forward estimated residual cost rate based on P5min runs. These high-level estimates (i.e. assuming that all is unused FCAS) will be provided for each constraint for each 5 minute pre-dispatch interval.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNNO","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+RREG_0220","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/28 19:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 5 minute predispatch case that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis of these forward estimates)","examples":["2026/09/28 19:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 5 minute predispatch case run number that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis for these forward estimates)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The version number of the effective default contribution factor for the unit / constraint combination taken from the FPP_FORECAST_DEFAULT_CF table","examples":["131"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EST_UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated unused recovery FCAS in AUD/MWh (the forward financial estimate of the recovery of unused FCAS, assuming that all is unused FCAS). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation. Please note that there may be cases where there is not yet a residual default contribution factor for the constraint (for example if there is a new constraint binding in p5min that has not yet bound in dispatch). In these scenarios there will be no EST_UNUSED_FCAS row sent for the constraint, as this is currently incalculable until a corresponding residual default contribution factor is calculated from a dispatch run with this constraint binding.","examples":["-0.00003125","-0.70108675"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/28 19:00:40"],"parse_csv_as_string":true,"is_s_datetime":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)","examples":["NSW1,QLD1,SA1,TAS1,VIC1","NSW1,QLD1,SA1,VIC1","TAS1"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_P5_FWD_EST_RESIDUALRATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2025,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3667200,"decompressed_size_all_time":6324441000},"visibility":"Public","trigger":"At the completion of a P5MIN estimation calculation run (i.e. every 5 mins)"},"FPP_PD_FWD_EST_COST":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"PD_FWD_EST_COST","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#73"],"comment":"This report delivers the forward estimated unit cost based on PREDISPATCH runs. These high-level estimates (i.e. assuming that all is unused FCAS) will be provided for each constraint for each 30 minute pre-dispatch interval.","primary_keys":["CONSTRAINTID","FPP_UNITID","INTERVAL_DATETIME","PREDISPATCHSEQNO","RUN_DATETIME","RUNNO","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","is_categorical":true},"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID / TNI)"},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the 30 minute predispatch interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Predispatch sequence number for the 30 minute predispatch case that triggers the constraint FCAS processor run","unsigned_int":true,"num_int_bits":32},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 30 minute predispatch case that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis of these forward estimates)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 30 minute predispatch case run number that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis for these forward estimates)","is_integer":true,"unsigned_int":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The version number of the effective default contribution factor for the unit / constraint combination taken from the FPP_FORECAST_DEFAULT_CF table","is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EST_UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated unused recovery FCAS in AUD (the forward financial estimate of the recovery of unused FCAS, assuming that all is unused FCAS). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation. Please note that there may be cases where there is not yet a default contribution factor for the constraint (for example if there is a new constraint binding in predispatch that has not yet bound in dispatch). In these scenarios there will be no EST_UNUSED_FCAS row sent for the constraint, as it is currently incalculable until a corresponding default contribution factor is calculated from a dispatch run with this constraint binding.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","is_categorical":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)"}},"visibility":"Private","trigger":"At the completion of a PREDISPATCH estimation calculation run (i.e. every 30 minutes)"},"FPP_PD_FWD_EST_RESIDUALRATE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"PD_FWD_EST_RESIDUALRATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#79"],"comment":"This report delivers the forward estimated residual cost rate based on PREDISPATCH runs. These high-level estimates (i.e. assuming that all is unused FCAS) will be provided for each constraint for each 30 minute pre- dispatch interval.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","PREDISPATCHSEQNO","RUN_DATETIME","RUNNO","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the 30 minute predispatch interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Predispatch sequence number for the 30 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026083018","2026090106"],"unsigned_int":true,"num_int_bits":32},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 30 minute predispatch case that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis of these forward estimates)","examples":["2026/08/30 13:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 30 minute predispatch case run number that was the trigger for the constraint FCAS processor execution (as the FCAS requirement data is the basis for these forward estimates)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The version number of the effective default contribution factor for the unit / constraint combination taken from the FPP_FORECAST_DEFAULT_CF table","examples":["125"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EST_UNUSED_FCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated unused recovery FCAS in AUD/MWh (the forward financial estimate of the recovery of unused FCAS, assuming that all is unused FCAS). This value will be either 0 (nil), or a negative value (debit) only. For details on the calculation, please see FPP procedure and supporting documentation. Please note that there may be cases where there is not yet a residual default contribution factor for the constraint (for example if there is a new constraint binding in predispatch that has not yet bound in dispatch). In these scenarios there will be no EST_UNUSED_FCAS row sent for the constraint, as this is currently incalculable until a corresponding residual default contribution factor is calculated from a dispatch run with this constraint binding.","examples":["-0.00002342","-1.75285789"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/30 12:33:05"],"parse_csv_as_string":true,"is_s_datetime":true},"RELEVANT_REGIONS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Relevant regions (a comma separated list of the relevant regions for the constraint from FCAS data)","examples":["NSW1,QLD1,SA1,TAS1,VIC1","NSW1,QLD1,SA1,VIC1","TAS1"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_PD_FWD_EST_RESIDUALRATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2025,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":2988199,"decompressed_size_all_time":5199792450},"visibility":"Public","trigger":"At the completion of a PREDISPATCH estimation calculation run (i.e. every 30 minutes)"},"FPP_PERFORMANCE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FPP_PERFORMANCE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#85"],"comment":"This report delivers the calculated performance value for each 5 minute trading interval for each FPP unit","primary_keys":["FPP_UNITID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID/ TNI)","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD_LOAD","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BOYNE_LOAD","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TOMAGO_LOAD","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12"]},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:00:22"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower performance value in MWHz units (calculated by FPP for that trading interval taken from FPP database)","examples":["-0.00007","0.00048","0","0.88449"],"is_float":true},"LOWER_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the lower performance value Supported values are: 0 = Performance is calculated based on good input data 1 = Performance is Null as unit is a Non Primary DUID in the group 2 = Performance against the Primary DUID representing the group 4 = Performance is Null as Input data is bad or unavailable 8 = Performance is Null as FM is unreliable 12 = Performance is Null as Input data is bad or unavailable and FM is unreliable 6 = Performance against the Primary DUID representing the group is Null as Input data is bad or unavailable 10 = Performance against the Primary DUID representing the group is Null as FM is unreliable 14 = Performance against the Primary DUID representing the group is Null as Input data is bad or unavailable and FM is unreliable","examples":["0","1","12"],"is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","examples":["AGLLBESS","ALCOAPA","ALDOGASF","ALNTARES","ALNTBHWF","ARARATWF","B2PS","BALBESS","BANGOWF2","BBPEM","BERBANK","BERBANKW","BERYBKWF","BLYTHBAT","BOCOROCK","BODWF1","BOMENSF","BORAL","BOULBESS","BRNDBESS","BULGANA","BUNGALA1","BUNGALA2","BUNGBESS","BUSF","BWFTRUST","CAPBESS","CAPEBYRN","CAPRISF","CAPTPL","CARWARP","CATHROCK","CGBESS","CHALLHWF","CHERRYWF","CLARESF1","CLEANCO","CLEMGPWF","CLERMSF","CNUNDAWF","COLEAMSF","COLLECWF","COLUMSF","COOPGWF","COROWASF","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CULLRGWF","CUSF","DALRYMPN","DARLSF","DAYDSF","DDSF","DIAMDGEN","DIAMOND","DPNTBESS","DULACCA","DUNDWF","ECOGEN","EDENVALE","EDISON","EDLCSMQ","EEQGEN","EEQLILY","EEQMEWF","ENELAUS","EQMREHA1","EQMREHA2","ERMPOWER","FINLEYSF","FRVROYAL","FSNSW","GANNBESS","GANNSF","GBATEAST","GESF","GLENROSF","GLENSF","GOON","GPWF1","GPWF2","GRANHAWF","GRIFFITH","GSPOWER","GSWF1A","GSWF1B","GUNNEDAH","GUNNING","GUNSYND","HALLETT","HAMISF","HAUGHTSF","HAWKES","HAYMSF","HBESS","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HUGSF","HWF3","HYDROTAS","JUNEESF","KARSF","KENNEDYE","KERANGSP","KIATAPRJ","KIDSPHES","KINGARSF","KOORBESS","KSFPROJT","LALLALWF","LANCASF","LIMBESS","LIMONSF","LINGAPWF","LKBWFBES","LKBWIND","LOYYANGA","LVES","MACINTYR","MACQGEN","MANILDRA","MANNUMB","MANNUMS2","MBAHNTH","METPL","METZSF","MOKOANSF","MOLONGOP","MONDO","MOORAWF","MOREEAC","MORTLSWF","MOUSF","MRNBESS","MTGELLWF","MTMERCER","MTMILLAR","MUGGALSP","MULWALSF","MUNCRKSF","MUWARRA2","MWARRA","NESBESS","NEWENGSF","NEWGEN","NEWGRWF","NPSAIL","NUMURKSF","NVTSF","OEBESS","OERARING","ORANBESS","PEAKCO","PLBESS1","PORTADL","PSF","QGCSALE1","QUORNPSF","RANGBESS","RIVEBESS","ROSSRVER","RYAN","RYEPARK","SALTCRK","SAPHWF1","SAWCML","SEBSF","SECGEN","SHELLNEW","SITHE","SLVRTN","SMCTSV","SMFBESS","SMTHBESS","SNODE1","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SOUTHHYD","SOUTHYD2","SRSF1","STANCCWF","STANRET","STANWELL","STARFISH","STOCKYRD","STUBB1SF","SUNRSF","SUNTOP","TAILEM","TALL","TARALGA","TBSF","TELSTRAE","TIPSCO","TLTSFS","TOMAGOAC","TRANSGBH","TRGBESS","TRUDW","ULPBESS1","WHECKSON","WILDCATL","WOOLNWF","XELIO","YESSA","ZENENGEN"],"is_categorical":true},"RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise performance value in MWHz units (calculated by FPP for that trading interval taken from FPP database)","examples":["-0.00245","0.00005","0","30.18222"],"is_float":true},"RAISE_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the raise performance value Supported values are: 0 = Performance is calculated based on good input data 1 = Performance is Null as unit is a Non Primary DUID in the group 2 = Performance against the Primary DUID representing the group 4 = Performance is Null as Input data is bad or unavailable 8 = Performance is Null as FM is unreliable 12 = Performance is Null as Input data is bad or unavailable and FM is unreliable 6 = Performance against the Primary DUID representing the group is Null as Input data is bad or unavailable 10 = Performance against the Primary DUID representing the group is Null as FM is unreliable 14 = Performance against the Primary DUID representing the group is Null as Input data is bad or unavailable and FM is unreliable","examples":["0","1","4"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_PERFORMANCE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":48114403,"decompressed_size_all_time":57636446810},"visibility":"Private & Public Next-Day","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"The private report delivers at the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)The public report delivers the next market day (at a time after 4 am market time)"},"FPP_RCR":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FPP_RCR","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#91"],"comment":"This report delivers the calculated RCR for each constraint for each 5 minute trading interval","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"RCR":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RCR (the calculated requirement for corrective response from FPP database)","examples":["7.03881","0","1133.91928"],"is_float":true},"RCR_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the requirement for corrective response (RCR) calculation Supported values are: 0 = RCR is calculated based on good input data 1 = RCR is 0 as FM is unreliable 2 = RCR is 0 as the percentage of units with unavailable input or bad data is greater than the threshold percentage","examples":["0","1","2"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_RCR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":327471,"decompressed_size_all_time":631146490},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_REGION_FREQ_MEASURE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"REGION_FREQ_MEASURE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#97"],"comment":"This report delivers the curated 4 second frequency deviation and frequency measure data for each region","primary_keys":["INTERVAL_DATETIME","MEASUREMENT_DATETIME","REGIONID","VERSIONNO"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MEASUREMENT_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the SCADA data (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:00:04"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID of the frequency deviation / frequency measure","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"FM_ALIGNMENT_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Boolean","mandatory":false,"comment":"Alignment Flag (4 second frequency deviation is aligned with 4 second frequency measure for that region) Supported values are: 0 = Misaligned 1 = Aligned","examples":["0","1"],"is_boolean":true},"FREQ_DEVIATION_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Deviation (4 second frequency deviation in Hz for that region)","examples":["-0.001","0.001","0","0.065"],"is_float":true},"FREQ_MEASURE_HZ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated 4 second Frequency Measure for that region from FPP database","examples":["-0.00003285","0.00010003","-0.02822295","0.04382655"],"is_float":true},"HZ_QUALITY_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"Frequency Quality (4 second frequency deviation quality for that region) Supported values are: 0 = Bad Quality 1 = Good Quality 2 = Suspect Quality -1 = Value not used as input in the FPP calculation (generally used to indicate when SCADA data was late arriving after the FPP calculation commenced)","examples":["1"],"is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_REGION_FREQ_MEASURE%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":32480406,"decompressed_size_all_time":72525535790},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_RESIDUAL_CF":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"RESIDUAL_CF","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#103"],"comment":"This report delivers the calculated residual contribution factor value for each 5 minute trading interval for each constraint","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising contribution factors (CF) where a units performance is negative. For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["0.10022","0","3618.21287"],"is_float":true},"CF_ABS_POSITIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute positive performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising contribution factors (CF) where a units performance is positive. For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable","examples":["0.06446","0","3586.56892"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"NCF_ABS_NEGATIVE_PERF_TOTAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of absolute negative performance in MWHz for the combination of constraint / bid type (raise or lower). This is used as the denominator in normalising negative contribution factors (NCF). For further details please see the FPP procedure document. >0 = Performance was calculated for the units NULL = Performance for the units was unavailable 0 = When NCF is zero (i.e. CF is positive), then this total will be represented as zero","examples":["0.10022","0","3618.21992"],"is_float":true},"NEGATIVE_RESIDUAL_CF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Negative Residual Contribution Factor (the calculated negative residual contribution factor for the constraint ID for that trading interval) - for further details please see the FPP procedure document","examples":["-0.00002002","0","-0.9919338"],"is_float":true},"RESIDUAL_CF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Residual Contribution Factor (the calculated residual contribution factor for the constraint ID for that trading interval) - for further details please see the FPP procedure document","examples":["-0.00002002","0.0007425","0","0.90012985"],"is_float":true,"col_name_also_metadata":true},"RESIDUAL_CF_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the residual contribution factor (CF) Supported values are: 0 = CF is calculated based on good input data 8 = CF is 0 because FM is unreliable. 16 = CF is 0 because more than 50 percent input is bad or not available.","examples":["0","8","16"],"is_integer":true,"num_int_bits":32},"RESIDUAL_DCF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Residual Default Contribution Factor (the calculated residual default contribution factor based on historical performance for the constraint ID for that trading interval) that is effective for this trading interval, which joins back to FPP_FORECAST_RESIDUAL_DCF - for further details please see the FPP procedure document","examples":["-0.08762999","-0.63949506"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_RESIDUAL_CF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":777674,"decompressed_size_all_time":1634226390},"visibility":"Public","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns RESIDUAL_CF. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"The public report will be delivered at the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_RESIDUAL_PERFORMANCE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"RESIDUAL_PERFORMANCE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#109"],"comment":"This report delivers the calculated residual performance value for each 5 minute trading interval","primary_keys":["INTERVAL_DATETIME","REGIONID","VERSIONNO"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID of the residual performance","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower performance value in MWHz units (calculated by FPP for that trading interval taken from FPP database)","examples":["-0.00075","0.00659","-648.26534","128.80915"],"is_float":true},"LOWER_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the lower performance value Supported values are: 0 = Performance is calculated based on good input data 4 = Performance is Null as Input data is bad or unavailable 8 = Performance is Null as FM is unreliable 12 = Performance is Null as Input data is bad or unavailable and FM is unreliable","examples":["0","8"],"is_integer":true,"num_int_bits":32},"RAISE_PERFORMANCE":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise performance value in MWHz units (calculated by FPP for that trading interval taken from FPP database)","examples":["-0.01546","0.00285","-1021.75449","299.7415"],"is_float":true},"RAISE_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the raise performance value Supported values are: 0 = Performance is calculated based on good input data 4 = Performance is Null as Input data is bad or unavailable 8 = Performance is Null as FM is unreliable 12 = Performance is Null as Input data is bad or unavailable and FM is unreliable","examples":["0","8"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_RESIDUAL_PERFORMANCE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":565210,"decompressed_size_all_time":1116928940},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"The public report delivers at the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_RUN":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FPP_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#115"],"comment":"This report delivers details of the 5-minute FPP calculation engine success failure outcome saved in FPP database","primary_keys":["INTERVAL_DATETIME","VERSIONNO"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"AUTHORISED_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time of the authorisation of this FPP calculation run (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time) - Note may be delayed in cases of ex-post calculation runs","examples":["2026/09/01 00:10:15"],"parse_csv_as_string":true,"is_s_datetime":true},"FPPRUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Completion time of the FPP calculation run (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_STATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The status of FPP_RUN at the time the data model extract report was run. Typical value is Completed","examples":["Completed"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":117003,"decompressed_size_all_time":194783570},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"FPP_UNIT_MW":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"UNIT_MW","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#121"],"comment":"This report delivers the curated 4 second measurement MW data for each FPP unit","primary_keys":["FPP_UNITID","INTERVAL_DATETIME","MEASUREMENT_DATETIME","VERSIONNO"],"columns":{"FPP_UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"FPP Unit ID (registered DUID/TNI)","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ANGAST1","APD_LOAD","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BOYNE_LOAD","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALL_B_1","CALL_B_2","CAPBES1","CAPTL_WF","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CHALLHWF","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLOVER","CLRKCWF1","CLUNY","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DIAPURWF1","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERGT01","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GB01","GERMCRK","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GRANWF1","GREENB1","GRIFSF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUGSF1","HUMENSW","HUMEV","HVWWBA1","HVWWPV1","INVICTA","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KIAMSF1","KIATAWF1","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LBB1","LEM_WIL","LGAPWF1","LGAPWF2","LILYSF1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLSP1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","OSB-AG","PALOONA","PAREPS1","PAREPW1","PARSF1","PIBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","RANGEB1","REECE1","REECE2","REPULSE","RESS1","RIVNB2","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SNAPPER1","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TIB1","TNPS1","TOMAGO_LOAD","TORRB1","TORRB2","TORRB3","TORRB4","TREVALLN","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VENUS1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WANDB1","WANDSF1","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDBESS1","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WINTSF1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YAMBUKWF","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YSWF1","YWPS1","YWPS2","YWPS3","YWPS4"]},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2025/01/07 18:10:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MEASUREMENT_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the SCADA data (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2025/01/07 18:06:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"DEVIATION_MW":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Unit Deviation (output of the FPP calculation process)","examples":["-0.00047","0.00001","0","8"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MEASURED_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Measured MW (4 second SCADA measurement in MW)","examples":["-0.003","0.0000065","0","349"],"is_float":true},"MW_QUALITY_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"MW Quality (4 second SCADA measurement Quality) Supported values are: 0 = Bad Quality 1 = Good Quality 2 = Suspect Quality -1 = Value not used as input in the FPP calculation (generally used to indicate when SCADA data was late arriving after the FPP calculation commenced)","examples":["0","1","2"],"is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID","examples":["AGLWBESS","ALCOAPA","ALNTARES","ALNTBHWF","ARARATWF","B2PS","BALBESS","BANGOWF2","BBPEM","BERBANK","BERBANKW","BERYBKWF","BLYTHBAT","BOCOROCK","BODWF1","BOMENSF","BORAL","BOULBESS","BULGANA","BUNGALA1","BUNGALA2","BWFTRUST","CAPBESS","CAPEBYRN","CAPRISF","CAPTPL","CATHROCK","CHALLHWF","CHERRYWF","CLARESF1","CLEANCO","CLEMGPWF","CLERMSF","CNUNDAWF","COLEAMSF","COLLECWF","COLUMSF","COOPGWF","COROWASF","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CULLRGWF","DALRYMPN","DARLSF","DAYDSF","DDSF","DELTA","DIAMDGEN","DIAMOND","DPNTBESS","DULACCA","DUNDWF","ECOGEN","EDENVALE","EDISON","EDLCSMQ","EEQGEN","EEQLILY","EEQMEWF","ENELAUS","ENOCMASP","EPVIC1","ERMPOWER","FINLEYSF","FRVROYAL","FSNSW","GANNBESS","GANNSF","GLENROSF","GLENSF","GOON","GPWF1","GRANHAWF","GRIFFITH","GSPOWER","GSWF1A","GSWF1B","GUNNEDAH","GUNNING","HALLETT","HAMISF","HAUGHTSF","HAWKES","HAYMSF","HBESS","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HTWIND","HUGSF","HWF3","HYDROTAS","JEMASF","JUNEESF","KABANWF","KARSF","KENNEDYE","KERANGSP","KIATAPRJ","KIDSTON","KINGARSF","KSFPROJT","LALLALWF","LIGHTSRC","LIMONSF","LINGAPWF","LKBWFBES","LKBWIND","LOYYANGA","MACINTYR","MACQGEN","MANILDRA","MANNUMS2","MBAHNTH","METPL","METZSF","MOKOANSF","MOLONGOP","MONDO","MOORAWF","MOREEAC","MORTLSWF","MORTONSL","MOUSF","MTGELLWF","MTMERCER","MTMILLAR","MUGGALSP","MUWARRA2","MWARRA","NEWENGSF","NEWGEN","NEWGRWF","NPSAIL","NUMURKSF","NVTSF","OERARING","PEAKCO","PORTADL","PSF","PYRENEES","QGCSALE1","QPMENGY","RANGBESS","RIVEBESS","ROSSRVER","RYAN","RYEPARK","SALTCRK","SAPHWF1","SAWCML","SEBSF","SHELLNEW","SITHE","SLVRTN","SMCTSV","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SOUTHHYD","SOUTHYD2","SRSF1","STANCCWF","STANRET","STANWELL","STARFISH","STOCKYRD","STUBB1SF","SUNRSF","SUNSPOT3","SUNTOP","TAILEM","TALL","TARALGA","TBSOL","TELSTRAE","TIPSCO","TLTSFS","TOMAGOAC","TRANSGBH","TRUDW","UNIQLDSF","VICBAT","WAGGAOPS","WALGBESS","WANDOAN","WATERLWF","WDOWBESS","WDOWNS","WELLNTH","WEMENSF","WGWF","WHECKSON","WILDCATL","WINTONSF","WLWLSF1","WLWLSF2","WOLLARSF","WOODLAWN","WOOLOOGA","WROCKWF","WSUNDAY","WTAHBESS","WYALONG","WYASF","XELIO","YALLOURN","YALSTHWF","YARRANSF","YARWUN","YATSF","YESSA"],"is_categorical":true},"SCHEDULED_MW":{"sql_type":"NUMBER(18,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Scheduled MW (reference trajectory value from FPP calculation process)","examples":["-0.01","0.00067","0","685"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_12/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_UNIT_MW%23FILE01%23202412010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2024,"month":12},"compressed_size_per_month":109491672,"decompressed_size_all_time":1094916720},"visibility":"Private & Public Next-Day","trigger":"The private report delivers at the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)The public report delivers the next market day (at 4 am)"},"FPP_USAGE":{"package":"FPP","pdr_config":{"mappings":[{"REPORT_NAME":"FPP","REPORT_SUB_TYPE":"FPP_USAGE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec79.htm#127"],"comment":"This report delivers the calculated usage for each constraint for each 5 minute trading interval","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint ID (binding constraint ID from FCAS data used in FPP calculations)","examples":["F_I+GFT_TG_R5","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_MAIN++RREG_0220","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time of the trading interval (DD/MM/YYYY HH24:MI:SS) fixed to the UTC+10 time zone (NEM time)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version (FPP run number from the FPP database)","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (the bid type saved in relation to constraint ID from FCAS data used in FPP calculations)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:10:20"],"parse_csv_as_string":true,"is_s_datetime":true},"REGULATION_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabled regulation MW used in the FPP calculation (from FPP database)","examples":["160.00001","0","40","338"],"is_float":true},"USAGE_REASON_FLAG":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":false,"comment":"The reason flag showing the decision matrix for the usage calculation Supported values are: 0 = Usage is calculated based on good input data 1 = Usage is 0 as FM is unreliable 2 = Usage is 0 as the percentage of units with unavailable input or bad data is greater than the threshold percentage","examples":["0","1","2"],"is_integer":true,"num_int_bits":32},"USAGE_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage (calculation of the proportion of regulation FCAS that was calculated to be used)","examples":["0.0007998","0","1","0.99992818"],"is_float":true},"USED_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum used regulation MW value (quantity of regulation FCAS that was calculated to be used in MW)","examples":["0.03999","0","1","170"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23FPP_USAGE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":478717,"decompressed_size_all_time":994717040},"visibility":"Public","trigger":"At the completion of an FPP calculation run for a closed trading interval (i.e. every 5 minutes)"},"GDINSTRUCT":{"package":"GD_INSTRUCT","pdr_config":{"mappings":[{"REPORT_NAME":"GD_INSTRUCT","REPORT_SUB_TYPE":"GDINSTRUCT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec27.htm#1"],"comment":"GDINSTRUCT shows all manually issued dispatch instructions for a dispatchable unit. Ancillary Service instructions are to enable and to disable (i.e. 2 separate instructions) a service. Non-conforming units are also instructed via this facility. However, this facility is not the same as the market notice.","description":"Source\n\nGDINSTRUCT updates on issue of an instruction by AEMO, with visibility\nrestricted on the day of issue to the relevant participant. All\nparticipants have previous days' data available.","primary_keys":["ID"],"indexes":[["LASTCHANGED"],["DUID"],["TARGETTIME"]],"columns":{"ID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Instruction ID (sequential number)","examples":["786809","786811"],"is_integer":true,"num_int_bits":128},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorised by","examples":["JDUQUE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/07/01 03:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable unit identifier","examples":["PPCCGT","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INSTLEVEL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Instruction target level","examples":["0","42"],"is_integer":true,"num_int_bits":32},"INSTRUCTIONCLASSID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Instruction class","examples":["NEMMCO"]},"INSTRUCTIONSUBTYPEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Instruction sub type","examples":["OFFSYNCOMP","ONSYNCOMP"]},"INSTRUCTIONTYPEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Instruction type","examples":["AS_RP"]},"ISSUEDTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date / time issued","examples":["2026/07/01 03:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/07/01 02:56:48"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","examples":["NPSAIL"],"is_categorical":true},"REASON":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Reason","examples":["Required for AS_RP_Voltage Control"]},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Station Identifier","examples":["NPPPPS"],"is_categorical":true},"TARGETTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date / time instruction to apply","examples":["2026/06/30 22:35:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GDINSTRUCT%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":7},"has_missing_months":true,"compressed_size_per_month":560,"decompressed_size_all_time":460400},"visibility":"Public","trigger":"On instruction issued by AEMO"},"GENCONDATA":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENCONDATA","REPORT_SUB_TYPE":"NULL","VERSION":6},{"REPORT_NAME":"GENCONDATA","REPORT_SUB_TYPE":"NULL","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#9"],"comment":"GENCONDATA sets out the generic constraints contained within a generic constraint set invoked in PASA, predispatch and dispatch.\nFields enable selective application of invoked constraints in the Dispatch, Predispatch, ST PASA or MT PASA processes.","description":"GENCONDATA is a public data, and is available to all participants.\n\nSource\n\nGENCONDATA updates as constraint details are updated by AEMO.\n\nNote\n\nThe following fields enable selective application of invoked constraints\nin the Dispatch, Predispatch, ST PASA or MT PASA processes:\n\n· DISPATCH\n\n· PREDISPATCH\n\n· STPASA\n\n· MTPASA\n\nThe flag P5MIN_SCOPE_OVERRIDE indicates for each constraint whether 5MPD\nmakes use of the default Dispatch (P5MIN_SCOPE_OVERRIDE = NULL) or\nPre-dispatch (P5MIN_SCOPE_OVERRIDE = ‘PD’) style RHS definition.\nGENERICCONSTRAINTRHS stores generic constraint RHS definitions.\nConstraints without records in GENERICCONSTRAINTRHS only make use of the\nstatic RHS defined in the CONSTRAINTVALUE column in GENCONDATA .\n\nThe default value for the P5MIN_SCOPE_OVERRIDE column is NULL, so\nconstraints existing before implementing the column use the DISPATCH RHS\ndefinition by default, as was the case before the implementation of the\nchange.","primary_keys":["EFFECTIVEDATE","GENCONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this constraint","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique ID for the constraint","examples":["#DRYCGT1_D_E","#DRYCGT2_D_E","#R036713_001_RAMP_F","#R036713_001_RAMP_V","#R036714_001_RAMP_F","#R036714_001_RAMP_V","#R036715_001_RAMP_F","#R036715_001_RAMP_V","#R036715_002_RAMP_F","#R036715_002_RAMP_V","#R036715_003_RAMP_F","#R036715_003_RAMP_V","#R036716_001_RAMP_F","#R036716_001_RAMP_V","#R036717_001_RAMP_F","#R036717_001_RAMP_V","#R036717_002_RAMP_F","#R036717_002_RAMP_V","#R036717_003_RAMP_F","#R036717_003_RAMP_V","#R036717_004_RAMP_F","#R036717_004_RAMP_V","#R036717_005_RAMP_F","#R036717_005_RAMP_V","#R036718_001_RAMP_F","#R036718_001_RAMP_V","#R036718_002_RAMP_F","#R036718_002_RAMP_V","#R036718_003_RAMP_F","#R036718_003_RAMP_V","#R036718_004_RAMP_F","#R036718_004_RAMP_V","#R036718_005_RAMP_F","#R036718_005_RAMP_V","#R036718_006_RAMP_F","#R036718_006_RAMP_V","#R036718_007_RAMP_F","#R036718_007_RAMP_V","#R036719_001_RAMP_F","#R036719_001_RAMP_V","#R036719_002_RAMP_F","#R036719_002_RAMP_V","#R036719_003_RAMP_F","#R036719_003_RAMP_V","#R036719_004_RAMP_F","#R036719_004_RAMP_V","#R036719_005_RAMP_F","#R036719_005_RAMP_V","#R036719_006_RAMP_F","#R036719_006_RAMP_V","#R036719_007_RAMP_F","#R036719_007_RAMP_V","#R036720_001_RAMP_F","#R036720_001_RAMP_V","#R036720_002_RAMP_F","#R036720_002_RAMP_V","#R036720_003_RAMP_F","#R036720_003_RAMP_V","#R036720_004_RAMP_F","#R036720_004_RAMP_V","#R036721_001_RAMP_F","#R036721_001_RAMP_V","#R036721_002_RAMP_F","#R036721_002_RAMP_V","#R036721_003_RAMP_F","#R036721_003_RAMP_V","#R036721_004_RAMP_F","#R036721_004_RAMP_V","#R036721_005_RAMP_F","#R036721_005_RAMP_V","#R036721_006_RAMP_F","#R036721_006_RAMP_V","#R036721_007_RAMP_F","#R036721_007_RAMP_V","#R036721_008_RAMP_F","#R036721_008_RAMP_V","#R036721_009_RAMP_F","#R036721_009_RAMP_V","#R036721_010_RAMP_F","#R036721_010_RAMP_V","#R036721_011_RAMP_F","#R036721_011_RAMP_V","#R036721_012_RAMP_F","#R036721_012_RAMP_V","#R036721_013_RAMP_F","#R036721_013_RAMP_V","#R036721_014_RAMP_F","#R036721_014_RAMP_V","#R036721_015_RAMP_F","#R036721_015_RAMP_V","#R036721_016_RAMP_F","#R036721_016_RAMP_V","#R036721_017_RAMP_F","#R036721_017_RAMP_V","#R036721_018_RAMP_F","#R036721_018_RAMP_V","#R036721_019_RAMP_F","#R036721_019_RAMP_V","#R036721_020_RAMP_F","#R036721_020_RAMP_V","#R036721_021_RAMP_F","#R036721_021_RAMP_V","#R036722_001_RAMP_F","#R036722_001_RAMP_V","#R036722_002_RAMP_F","#R036722_002_RAMP_V","#R036722_003_RAMP_F","#R036722_003_RAMP_V","#R036722_004_RAMP_F","#R036722_004_RAMP_V","#R036723_001_RAMP_F","#R036723_001_RAMP_V","#R036723_002_RAMP_F","#R036723_002_RAMP_V","#R036724_001_RAMP_F","#R036724_001_RAMP_V","#R036725_001_RAMP_F","#R036725_001_RAMP_V","#R036725_002_RAMP_F","#R036725_002_RAMP_V","#R036725_003_RAMP_F","#R036725_003_RAMP_V","#R036725_004_RAMP_F","#R036725_004_RAMP_V","#R036725_005_RAMP_F","#R036725_005_RAMP_V","#R036725_006_RAMP_F","#R036725_006_RAMP_V","#R036725_007_RAMP_F","#R036725_007_RAMP_V","#R036725_008_RAMP_F","#R036725_008_RAMP_V","#R036725_009_RAMP_F","#R036725_009_RAMP_V","#R036726_001_RAMP_F","#R036726_001_RAMP_V","#R036727_001_RAMP_F","#R036727_001_RAMP_V","#R036728_001_RAMP_F","#R036728_001_RAMP_V","#R036728_002_RAMP_F","#R036728_002_RAMP_V","#R036729_001_RAMP_F","#R036729_001_RAMP_V","#R036729_002_RAMP_F","#R036729_002_RAMP_V","#R036730_001_RAMP_F","#R036730_001_RAMP_V","#R036731_001_RAMP_F","#R036731_001_RAMP_V","#R036731_002_RAMP_F","#R036731_002_RAMP_V","#R036731_003_RAMP_F","#R036731_003_RAMP_V","#R036731_004_RAMP_F","#R036731_004_RAMP_V","#R036731_005_RAMP_F","#R036731_005_RAMP_V","#R036731_006_RAMP_F","#R036731_006_RAMP_V","#R036731_007_RAMP_F","#R036731_007_RAMP_V","#R036731_008_RAMP_F","#R036731_008_RAMP_V","#R036731_009_RAMP_F","#R036731_009_RAMP_V","#R036732_001_RAMP_F","#R036732_001_RAMP_V","#R036732_002_RAMP_F","#R036732_002_RAMP_V","#R036732_003_RAMP_F","#R036732_003_RAMP_V","#R036732_004_RAMP_F","#R036732_004_RAMP_V","#R036732_005_RAMP_F","#R036732_005_RAMP_V","#R036733_001_RAMP_F","#R036733_001_RAMP_V","#R036733_002_RAMP_F","#R036733_002_RAMP_V","#R036734_001_RAMP_F","#R036734_001_RAMP_V","#R036734_002_RAMP_F","#R036734_002_RAMP_V","#R036735_001_RAMP_F","#R036735_001_RAMP_V","#R036735_002_RAMP_F","#R036735_002_RAMP_V","#R036736_001_RAMP_F","#R036736_001_RAMP_V","#R036736_002_RAMP_F","#R036736_002_RAMP_V","#R036737_001_RAMP_F","#R036737_001_RAMP_V","#R036737_002_RAMP_F","#R036737_002_RAMP_V","#R036738_001_RAMP_F","#R036738_001_RAMP_V","#R036738_002_RAMP_F","#R036738_002_RAMP_V","#R036739_001_RAMP_F","#R036739_001_RAMP_V","#R036740_001_RAMP_F","#R036740_001_RAMP_V","#R036741_001_RAMP_F","#R036741_001_RAMP_V","#R036741_002_RAMP_F","#R036741_002_RAMP_V","#R036742_001_RAMP_F","#R036742_001_RAMP_V","#R036742_002_RAMP_F","#R036742_002_RAMP_V","#R036743_001_RAMP_F","#R036743_001_RAMP_V","#R036743_002_RAMP_F","#R036743_002_RAMP_V","#R036744_001_RAMP_F","#R036744_001_RAMP_V","#R036744_002_RAMP_F","#R036744_002_RAMP_V","#R036745_001_RAMP_F","#R036745_001_RAMP_V","#R036745_002_RAMP_F","#R036745_002_RAMP_V","#R036746_001_RAMP_F","#R036746_001_RAMP_V","#R036746_002_RAMP_F","#R036746_002_RAMP_V","#R036747_001_RAMP_F","#R036747_001_RAMP_V","#R036747_002_RAMP_F","#R036747_002_RAMP_V","#R036748_001_RAMP_F","#R036748_001_RAMP_V","#R036748_002_RAMP_F","#R036748_002_RAMP_V","#R036749_001_RAMP_F","#R036749_001_RAMP_V","#R036749_002_RAMP_F","#R036749_002_RAMP_V","#R036750_001_RAMP_F","#R036750_001_RAMP_V","#R036750_002_RAMP_F","#R036750_002_RAMP_V","#R036751_001_RAMP_F","#R036751_001_RAMP_V","#R036751_002_RAMP_F","#R036751_002_RAMP_V","#R036752_001_RAMP_F","#R036752_001_RAMP_V","#R036752_002_RAMP_F","#R036752_002_RAMP_V","#R036753_001_RAMP_F","#R036753_001_RAMP_V","#R036753_002_RAMP_F","#R036753_002_RAMP_V","#R036754_001_RAMP_F","#R036754_001_RAMP_V","#R036755_001_RAMP_F","#R036755_001_RAMP_V","#R036756_001_RAMP_F","#R036756_001_RAMP_V","#R036757_001_RAMP_F","#R036757_001_RAMP_V","#R036758_001_RAMP_F","#R036758_001_RAMP_V","#R036759_001_RAMP_F","#R036759_001_RAMP_V","#R036760_001_RAMP_F","#R036760_001_RAMP_V","#R036761_001_RAMP_F","#R036761_001_RAMP_V","#R036762_001_RAMP_F","#R036762_001_RAMP_V","#R036762_002_RAMP_F","#R036762_002_RAMP_V","#R036762_003_RAMP_F","#R036762_003_RAMP_V","#R036763_001_RAMP_F","#R036763_001_RAMP_V","#R036763_002_RAMP_F","#R036763_002_RAMP_V","#R036764_001_RAMP_F","#R036764_001_RAMP_V","#R036764_002_RAMP_F","#R036764_002_RAMP_V","#R036764_003_RAMP_F","#R036764_003_RAMP_V","#R036765_001_RAMP_F","#R036765_001_RAMP_V","#R036765_002_RAMP_F","#R036765_002_RAMP_V","#R036765_003_RAMP_F","#R036765_003_RAMP_V","#R036765_004_RAMP_F","#R036765_004_RAMP_V","#R036765_005_RAMP_F","#R036765_005_RAMP_V","#R036765_006_RAMP_F","#R036765_006_RAMP_V","#R036765_007_RAMP_F","#R036765_007_RAMP_V","#R036766_001_RAMP_F","#R036766_001_RAMP_V","#R036766_002_RAMP_F","#R036766_002_RAMP_V","#R036767_001_RAMP_F","#R036767_001_RAMP_V","#R036767_002_RAMP_F","#R036767_002_RAMP_V","#R036768_001_RAMP_F","#R036768_001_RAMP_V","#R036769_001_RAMP_F","#R036769_001_RAMP_V","#R036770_001_RAMP_F","#R036770_001_RAMP_V","#R036771_001_RAMP_F","#R036771_001_RAMP_V","#R036772_001_RAMP_F","#R036772_001_RAMP_V","#R036772_002_RAMP_F","#R036772_002_RAMP_V","#R036772_003_RAMP_F","#R036772_003_RAMP_V","#R036773_001_RAMP_F","#R036773_001_RAMP_V","#R036774_001_RAMP_F","#R036774_001_RAMP_V","#R036775_001_RAMP_F","#R036775_001_RAMP_V","#R036775_002_RAMP_F","#R036775_002_RAMP_V","#R036775_003_RAMP_F","#R036775_003_RAMP_V","#R036776_001_RAMP_F","#R036776_001_RAMP_V","#R036776_002_RAMP_F","#R036776_002_RAMP_V","#R036777_001_RAMP_F","#R036777_001_RAMP_V","#R036777_002_RAMP_F","#R036777_002_RAMP_V","#R036777_003_RAMP_F","#R036777_003_RAMP_V","#R036777_004_RAMP_F","#R036777_004_RAMP_V","#R036778_001_RAMP_F","#R036778_001_RAMP_V","#R036779_001_RAMP_F","#R036779_001_RAMP_V","#R036779_002_RAMP_F","#R036779_002_RAMP_V","#R036780_001_RAMP_F","#R036780_001_RAMP_V","#R036781_001_RAMP_F","#R036781_001_RAMP_V","#R036781_002_RAMP_F","#R036781_002_RAMP_V","#R036782_001_RAMP_F","#R036782_001_RAMP_V","#R036782_002_RAMP_F","#R036782_002_RAMP_V","#R036783_001_RAMP_F","#R036783_001_RAMP_V","#R036783_002_RAMP_F","#R036783_002_RAMP_V","#R036783_003_RAMP_F","#R036783_003_RAMP_V","#R036783_004_RAMP_F","#R036783_004_RAMP_V","#R036783_005_RAMP_F","#R036783_005_RAMP_V","#R036783_006_RAMP_F","#R036783_006_RAMP_V","#R036783_007_RAMP_F","#R036783_007_RAMP_V","#R036783_008_RAMP_F","#R036783_008_RAMP_V","#R036783_009_RAMP_F","#R036783_009_RAMP_V","#R036783_010_RAMP_F","#R036783_010_RAMP_V","#R036783_011_RAMP_F","#R036783_011_RAMP_V","#R036783_012_RAMP_F","#R036783_012_RAMP_V","#R036783_013_RAMP_F","#R036783_013_RAMP_V","#R036783_014_RAMP_F","#R036783_014_RAMP_V","#R036783_015_RAMP_F","#R036783_015_RAMP_V","#R036783_016_RAMP_F","#R036783_016_RAMP_V","#R036783_017_RAMP_F","#R036783_017_RAMP_V","#R036783_018_RAMP_F","#R036783_018_RAMP_V","#R036783_019_RAMP_F","#R036783_019_RAMP_V","#R036783_020_RAMP_F","#R036783_020_RAMP_V","#R036783_021_RAMP_F","#R036783_021_RAMP_V","#R036783_022_RAMP_F","#R036783_022_RAMP_V","#R036783_023_RAMP_F","#R036783_023_RAMP_V","#R036783_024_RAMP_F","#R036783_024_RAMP_V","#R036783_025_RAMP_F","#R036783_025_RAMP_V","#R036783_026_RAMP_F","#R036783_026_RAMP_V","#R036783_027_RAMP_F","#R036783_027_RAMP_V","#R036783_028_RAMP_F","#R036783_028_RAMP_V","#R036783_029_RAMP_F","#R036783_029_RAMP_V","#R036783_030_RAMP_F","#R036783_030_RAMP_V","#R036783_031_RAMP_F","#R036783_031_RAMP_V","#R036783_032_RAMP_F","#R036783_032_RAMP_V","#R036783_033_RAMP_F","#R036783_033_RAMP_V","#R036783_034_RAMP_F","#R036783_034_RAMP_V","#R036783_035_RAMP_F","#R036783_035_RAMP_V","#R036783_036_RAMP_F","#R036783_036_RAMP_V","#R036783_037_RAMP_F","#R036783_037_RAMP_V","#R036783_038_RAMP_F","#R036783_038_RAMP_V","#R036783_039_RAMP_F","#R036783_039_RAMP_V","#R036783_040_RAMP_F","#R036783_040_RAMP_V","#R036783_041_RAMP_F","#R036783_041_RAMP_V","#R036783_042_RAMP_F","#R036783_042_RAMP_V","#R036783_043_RAMP_F","#R036783_043_RAMP_V","#R036783_044_RAMP_F","#R036783_044_RAMP_V","#R036783_045_RAMP_F","#R036783_045_RAMP_V","#R036783_046_RAMP_F","#R036783_046_RAMP_V","#R036784_001_RAMP_F","#R036784_001_RAMP_V","#R036784_002_RAMP_F","#R036784_002_RAMP_V","#R036784_003_RAMP_F","#R036784_003_RAMP_V","#R036784_004_RAMP_F","#R036784_004_RAMP_V","#R036785_001_RAMP_F","#R036785_001_RAMP_V","#R036785_002_RAMP_F","#R036785_002_RAMP_V","#R036785_003_RAMP_F","#R036785_003_RAMP_V","#R036785_004_RAMP_F","#R036785_004_RAMP_V","#R036785_005_RAMP_F","#R036785_005_RAMP_V","#R036785_006_RAMP_F","#R036785_006_RAMP_V","#R036785_007_RAMP_F","#R036785_007_RAMP_V","#R036785_008_RAMP_F","#R036785_008_RAMP_V","#R036785_009_RAMP_F","#R036785_009_RAMP_V","#R036785_010_RAMP_F","#R036785_010_RAMP_V","#R036785_011_RAMP_F","#R036785_011_RAMP_V","#R036785_012_RAMP_F","#R036785_012_RAMP_V","#R036785_013_RAMP_F","#R036785_013_RAMP_V","#R036785_014_RAMP_F","#R036785_014_RAMP_V","#R036785_015_RAMP_F","#R036785_015_RAMP_V","#R036785_016_RAMP_F","#R036785_016_RAMP_V","#R036785_017_RAMP_F","#R036785_017_RAMP_V","#R036785_018_RAMP_F","#R036785_018_RAMP_V","#R036785_019_RAMP_F","#R036785_019_RAMP_V","#R036785_020_RAMP_F","#R036785_020_RAMP_V","#R036785_021_RAMP_F","#R036785_021_RAMP_V","#R036785_022_RAMP_F","#R036785_022_RAMP_V","#R036785_023_RAMP_F","#R036785_023_RAMP_V","#R036785_024_RAMP_F","#R036785_024_RAMP_V","#R036785_025_RAMP_F","#R036785_025_RAMP_V","#R036785_026_RAMP_F","#R036785_026_RAMP_V","#R036785_027_RAMP_F","#R036785_027_RAMP_V","#R036785_028_RAMP_F","#R036785_028_RAMP_V","#R036785_029_RAMP_F","#R036785_029_RAMP_V","#R036785_030_RAMP_F","#R036785_030_RAMP_V","#R036786_001_RAMP_F","#R036786_001_RAMP_V","#R036786_002_RAMP_F","#R036786_002_RAMP_V","#R036787_001_RAMP_F","#R036787_001_RAMP_V","#R036787_002_RAMP_F","#R036787_002_RAMP_V","#R036787_003_RAMP_F","#R036787_003_RAMP_V","#R036787_004_RAMP_F","#R036787_004_RAMP_V","#R036787_005_RAMP_F","#R036787_005_RAMP_V","#R036787_006_RAMP_F","#R036787_006_RAMP_V","#R036787_007_RAMP_F","#R036787_007_RAMP_V","#R036787_008_RAMP_F","#R036787_008_RAMP_V","#R036787_009_RAMP_F","#R036787_009_RAMP_V","#R036787_010_RAMP_F","#R036787_010_RAMP_V","#R036787_011_RAMP_F","#R036787_011_RAMP_V","#R036787_012_RAMP_F","#R036787_012_RAMP_V","#R036787_013_RAMP_F","#R036787_013_RAMP_V","#R036787_014_RAMP_F","#R036787_014_RAMP_V","#R036787_015_RAMP_F","#R036787_015_RAMP_V","#R036787_016_RAMP_F","#R036787_016_RAMP_V","#R036787_017_RAMP_F","#R036787_017_RAMP_V","#R036787_018_RAMP_F","#R036787_018_RAMP_V","#R036787_019_RAMP_F","#R036787_019_RAMP_V","#R036787_020_RAMP_F","#R036787_020_RAMP_V","#R036787_021_RAMP_F","#R036787_021_RAMP_V","#R036787_022_RAMP_F","#R036787_022_RAMP_V","#R036787_023_RAMP_F","#R036787_023_RAMP_V","#R036787_024_RAMP_F","#R036787_024_RAMP_V","#R036787_025_RAMP_F","#R036787_025_RAMP_V","#R036787_026_RAMP_F","#R036787_026_RAMP_V","#R036787_027_RAMP_F","#R036787_027_RAMP_V","#R036787_028_RAMP_F","#R036787_028_RAMP_V","#R036787_029_RAMP_F","#R036787_029_RAMP_V","#R036787_030_RAMP_F","#R036787_030_RAMP_V","#R036787_031_RAMP_F","#R036787_031_RAMP_V","#R036787_032_RAMP_F","#R036787_032_RAMP_V","#R036787_033_RAMP_F","#R036787_033_RAMP_V","#R036787_034_RAMP_F","#R036787_034_RAMP_V","#R036787_035_RAMP_F","#R036787_035_RAMP_V","#R036787_036_RAMP_F","#R036787_036_RAMP_V","#R036787_037_RAMP_F","#R036787_037_RAMP_V","#R036787_038_RAMP_F","#R036787_038_RAMP_V","#R036787_039_RAMP_F","#R036787_039_RAMP_V","#R036787_040_RAMP_F","#R036787_040_RAMP_V","#R036787_041_RAMP_F","#R036787_041_RAMP_V","#R036787_042_RAMP_F","#R036787_042_RAMP_V","#R036787_043_RAMP_F","#R036787_043_RAMP_V","#R036787_044_RAMP_F","#R036787_044_RAMP_V","#R036787_045_RAMP_F","#R036787_045_RAMP_V","#R036787_046_RAMP_F","#R036787_046_RAMP_V","#R036787_047_RAMP_F","#R036787_047_RAMP_V","#R036787_048_RAMP_F","#R036787_048_RAMP_V","#R036787_049_RAMP_F","#R036787_049_RAMP_V","#R036787_050_RAMP_F","#R036787_050_RAMP_V","#R036787_051_RAMP_F","#R036787_051_RAMP_V","#R036787_052_RAMP_F","#R036787_052_RAMP_V","#R036787_053_RAMP_F","#R036787_053_RAMP_V","#R036787_054_RAMP_F","#R036787_054_RAMP_V","#R036787_055_RAMP_F","#R036787_055_RAMP_V","#R036787_056_RAMP_F","#R036787_056_RAMP_V","#R036787_057_RAMP_F","#R036787_057_RAMP_V","#R036787_058_RAMP_F","#R036787_058_RAMP_V","#R036787_059_RAMP_F","#R036787_059_RAMP_V","#R036787_060_RAMP_F","#R036787_060_RAMP_V","#R036787_061_RAMP_F","#R036787_061_RAMP_V","#R036787_062_RAMP_F","#R036787_062_RAMP_V","#R036787_063_RAMP_F","#R036787_063_RAMP_V","#R036788_001_RAMP_F","#R036788_001_RAMP_V","#R036788_002_RAMP_F","#R036788_002_RAMP_V","#R036789_001_RAMP_F","#R036789_001_RAMP_V","#R036790_001_RAMP_F","#R036790_001_RAMP_V","#R036790_002_RAMP_F","#R036790_002_RAMP_V","#R036790_003_RAMP_F","#R036790_003_RAMP_V","#R036790_004_RAMP_F","#R036790_004_RAMP_V","#R036790_005_RAMP_F","#R036790_005_RAMP_V","#R036790_006_RAMP_F","#R036790_006_RAMP_V","#R036790_007_RAMP_F","#R036790_007_RAMP_V","#R036791_001_RAMP_F","#R036791_001_RAMP_V","#R036791_002_RAMP_F","#R036791_002_RAMP_V","#R036792_001_RAMP_F","#R036792_001_RAMP_V","#R036792_002_RAMP_F","#R036792_002_RAMP_V","#R036792_003_RAMP_F","#R036792_003_RAMP_V","#R036793_001_RAMP_F","#R036793_001_RAMP_V","#R036793_002_RAMP_F","#R036793_002_RAMP_V","#R036793_003_RAMP_F","#R036793_003_RAMP_V","#R036793_004_RAMP_F","#R036793_004_RAMP_V","#R036793_005_RAMP_F","#R036793_005_RAMP_V","#R036793_006_RAMP_F","#R036793_006_RAMP_V","#R036793_007_RAMP_F","#R036793_007_RAMP_V","#R036794_001_RAMP_F","#R036794_001_RAMP_V","#R036794_002_RAMP_F","#R036794_002_RAMP_V","#R036794_003_RAMP_F","#R036794_003_RAMP_V","#R036794_004_RAMP_F","#R036794_004_RAMP_V","#R036794_005_RAMP_F","#R036794_005_RAMP_V","#R036794_006_RAMP_F","#R036794_006_RAMP_V","#R036794_007_RAMP_F","#R036794_007_RAMP_V","#R036794_008_RAMP_F","#R036794_008_RAMP_V","#R036794_009_RAMP_F","#R036794_009_RAMP_V","#R036794_010_RAMP_F","#R036794_010_RAMP_V","#R036794_011_RAMP_F","#R036794_011_RAMP_V","#R036795_001_RAMP_F","#R036795_001_RAMP_V","#R036795_002_RAMP_F","#R036795_002_RAMP_V","#R036795_003_RAMP_F","#R036795_003_RAMP_V","#R036795_004_RAMP_F","#R036795_004_RAMP_V","#R036795_005_RAMP_F","#R036795_005_RAMP_V","#R036795_006_RAMP_F","#R036795_006_RAMP_V","#R036795_007_RAMP_F","#R036795_007_RAMP_V","#R036795_008_RAMP_F","#R036795_008_RAMP_V","#R036795_009_RAMP_F","#R036795_009_RAMP_V","#R036795_010_RAMP_F","#R036795_010_RAMP_V","#R036796_001_RAMP_V","#SSE_PPCCGT_20","#SSE_PPCCGT_21","#TORRB4_D_E","CA_SYDS_59A889E5_1","DSNAP_LRHS_1","DSNAP_LRHS_2","Q_2+1_R2_ALDGASF1","Q_2+1_R2_ALDGASF1_I","Q_2+1_R2_CLARESF1","Q_2+1_R2_CLARESF1_I","Q_2+1_R2_CSPVPS1","Q_2+1_R2_CSPVPS1_I","Q_2+1_R2_DAYDSF1","Q_2+1_R2_DAYDSF1_I","Q_2+1_R2_HAMISF1","Q_2+1_R2_HAMISF1_I","Q_2+1_R2_HAUGHT11","Q_2+1_R2_HAUGHT11_I","Q_2+1_R2_HAYMSF1","Q_2+1_R2_HAYMSF1_I","Q_2+1_R2_KABANWF1","Q_2+1_R2_KABANWF1_I","Q_2+1_R2_KEP","Q_2+1_R2_KEP_I","Q_2+1_R2_KSP1","Q_2+1_R2_KSP1_I","Q_2+1_R2_MEWF1","Q_2+1_R2_MEWF1_I","Q_2+1_R2_RRSF1","Q_2+1_R2_RRSF1_I","Q_2+1_R2_RUGBYR1","Q_2+1_R2_RUGBYR1_I","Q_2+1_R2_SMCSF1","Q_2+1_R2_SMCSF1_I","Q_2+1_R2_WHITSF1","Q_2+1_R2_WHITSF1_I","Q_2+1_R3_ALDGASF1","Q_2+1_R3_ALDGASF1_I","Q_2+1_R3_CLARESF1","Q_2+1_R3_CLARESF1_I","Q_2+1_R3_CSPVPS1","Q_2+1_R3_CSPVPS1_I","Q_2+1_R3_DAYDSF1","Q_2+1_R3_DAYDSF1_I","Q_2+1_R3_HAMISF1","Q_2+1_R3_HAMISF1_I","Q_2+1_R3_HAUGHT11","Q_2+1_R3_HAUGHT11_I","Q_2+1_R3_HAYMSF1","Q_2+1_R3_HAYMSF1_I","Q_2+1_R3_KABANWF1","Q_2+1_R3_KABANWF1_I","Q_2+1_R3_KEP","Q_2+1_R3_KEP_I","Q_2+1_R3_KSP1","Q_2+1_R3_KSP1_I","Q_2+1_R3_MEWF1","Q_2+1_R3_MEWF1_I","Q_2+1_R3_RRSF1","Q_2+1_R3_RRSF1_I","Q_2+1_R3_RUGBYR1","Q_2+1_R3_RUGBYR1_I","Q_2+1_R3_SMCSF1","Q_2+1_R3_SMCSF1_I","Q_2+1_R3_WHITSF1","Q_2+1_R3_WHITSF1_I","Q_2+1_R4_ALDGASF1","Q_2+1_R4_ALDGASF1_I","Q_2+1_R4_CLARESF1","Q_2+1_R4_CLARESF1_I","Q_2+1_R4_CSPVPS1","Q_2+1_R4_CSPVPS1_I","Q_2+1_R4_DAYDSF1","Q_2+1_R4_DAYDSF1_I","Q_2+1_R4_HAMISF1","Q_2+1_R4_HAMISF1_I","Q_2+1_R4_HAUGHT11","Q_2+1_R4_HAUGHT11_I","Q_2+1_R4_HAYMSF1","Q_2+1_R4_HAYMSF1_I","Q_2+1_R4_KABANWF1","Q_2+1_R4_KABANWF1_I","Q_2+1_R4_KEP","Q_2+1_R4_KEP_I","Q_2+1_R4_KSP1","Q_2+1_R4_KSP1_I","Q_2+1_R4_MEWF1","Q_2+1_R4_MEWF1_I","Q_2+1_R4_RRSF1","Q_2+1_R4_RRSF1_I","Q_2+1_R4_RUGBYR1","Q_2+1_R4_RUGBYR1_I","Q_2+1_R4_SMCSF1","Q_2+1_R4_SMCSF1_I","Q_2+1_R4_WHITSF1","Q_2+1_R4_WHITSF1_I","Q_2+3+VC_CLARESF1","Q_2+3+VC_CLARESF1_I","Q_2+3+VC_CSPVPS1","Q_2+3+VC_CSPVPS1_I","Q_2+3+VC_DAYDSF1","Q_2+3+VC_DAYDSF1_I","Q_2+3+VC_HAMISF1","Q_2+3+VC_HAMISF1_I","Q_2+3+VC_HAUGHT11","Q_2+3+VC_HAUGHT11_I","Q_2+3+VC_HAYMSF1","Q_2+3+VC_HAYMSF1_I","Q_2+3+VC_KABANWF1","Q_2+3+VC_KABANWF1_I","Q_2+3+VC_KEP","Q_2+3+VC_KEP_I","Q_2+3+VC_KSP1","Q_2+3+VC_KSP1_I","Q_2+3+VC_MEWF1","Q_2+3+VC_MEWF1_I","Q_2+3+VC_RRSF1","Q_2+3+VC_RRSF1_I","Q_2+3+VC_RUGBYR1","Q_2+3+VC_RUGBYR1_I","Q_2+3+VC_SMCSF1","Q_2+3+VC_SMCSF1_I","Q_2+3+VC_WHITSF1","Q_2+3+VC_WHITSF1_I","Q_2+BCLC_ALDGASF1","Q_2+BCLC_ALDGASF1_I","Q_2+BCLC_BRDDSF01","Q_2+BCLC_BRDDSF01_I","Q_2+BCLC_CLARESF1","Q_2+BCLC_CLARESF1_I","Q_2+BCLC_CSPVPS1","Q_2+BCLC_CSPVPS1_I","Q_2+BCLC_DAYDSF1","Q_2+BCLC_DAYDSF1_I","Q_2+BCLC_HAMISF1","Q_2+BCLC_HAMISF1_I","Q_2+BCLC_HAUGHT11","Q_2+BCLC_HAUGHT11_I","Q_2+BCLC_HAYMSF1","Q_2+BCLC_HAYMSF1_I","Q_2+BCLC_KABANWF1","Q_2+BCLC_KABANWF1_I","Q_2+BCLC_KEP","Q_2+BCLC_KEP_I","Q_2+BCLC_KSP1","Q_2+BCLC_KSP1_I","Q_2+BCLC_MEWF1","Q_2+BCLC_MEWF1_I","Q_2+BCLC_RRSF1","Q_2+BCLC_RRSF1_I","Q_2+BCLC_RUGBYR1","Q_2+BCLC_RUGBYR1_I","Q_2+BCLC_SMCSF1","Q_2+BCLC_SMCSF1_I","Q_2+BCLC_WHITSF1","Q_2+BCLC_WHITSF1_I","Q_2+BCNE_ALDGASF1","Q_2+BCNE_ALDGASF1_I","Q_2+BCNE_CLARESF1","Q_2+BCNE_CLARESF1_I","Q_2+BCNE_CSPVPS1","Q_2+BCNE_CSPVPS1_I","Q_2+BCNE_DAYDSF1","Q_2+BCNE_DAYDSF1_I","Q_2+BCNE_HAMISF1","Q_2+BCNE_HAMISF1_I","Q_2+BCNE_HAUGHT11","Q_2+BCNE_HAUGHT11_I","Q_2+BCNE_HAYMSF1","Q_2+BCNE_HAYMSF1_I","Q_2+BCNE_KABANWF1","Q_2+BCNE_KABANWF1_I","Q_2+BCNE_KEP","Q_2+BCNE_KEP_I","Q_2+BCNE_KSP1","Q_2+BCNE_KSP1_I","Q_2+BCNE_MEWF1","Q_2+BCNE_MEWF1_I","Q_2+BCNE_RRSF1","Q_2+BCNE_RRSF1_I","Q_2+BCNE_RUGBYR1","Q_2+BCNE_RUGBYR1_I","Q_2+BCNE_SMCSF1","Q_2+BCNE_SMCSF1_I","Q_2+BCNE_WHITSF1","Q_2+BCNE_WHITSF1_I","Q_2+LCCP_ALDGASF1","Q_2+LCCP_ALDGASF1_I","Q_2+LCCP_CLARESF1","Q_2+LCCP_CLARESF1_I","Q_2+LCCP_CSPVPS1","Q_2+LCCP_CSPVPS1_I","Q_2+LCCP_DAYDSF1","Q_2+LCCP_DAYDSF1_I","Q_2+LCCP_HAMISF1","Q_2+LCCP_HAMISF1_I","Q_2+LCCP_HAUGHT11","Q_2+LCCP_HAUGHT11_I","Q_2+LCCP_HAYMSF1","Q_2+LCCP_HAYMSF1_I","Q_2+LCCP_KABANWF1","Q_2+LCCP_KABANWF1_I","Q_2+LCCP_KEP","Q_2+LCCP_KEP_I","Q_2+LCCP_KSP1","Q_2+LCCP_KSP1_I","Q_2+LCCP_MEWF1","Q_2+LCCP_MEWF1_I","Q_2+LCCP_RRSF1","Q_2+LCCP_RRSF1_I","Q_2+LCCP_RUGBYR1","Q_2+LCCP_RUGBYR1_I","Q_2+LCCP_SMCSF1","Q_2+LCCP_SMCSF1_I","Q_2+LCCP_WHITSF1","Q_2+LCCP_WHITSF1_I","Q_2+RSVC_ALDGASF1","Q_2+RSVC_ALDGASF1_I","Q_2+RSVC_CLARESF1","Q_2+RSVC_CLARESF1_I","Q_2+RSVC_CSPVPS1","Q_2+RSVC_CSPVPS1_I","Q_2+RSVC_DAYDSF1","Q_2+RSVC_DAYDSF1_I","Q_2+RSVC_HAMISF1","Q_2+RSVC_HAMISF1_I","Q_2+RSVC_HAUGHT11","Q_2+RSVC_HAUGHT11_I","Q_2+RSVC_HAYMSF1","Q_2+RSVC_HAYMSF1_I","Q_2+RSVC_KABANWF1","Q_2+RSVC_KABANWF1_I","Q_2+RSVC_KEP","Q_2+RSVC_KEP_I","Q_2+RSVC_KSP1","Q_2+RSVC_KSP1_I","Q_2+RSVC_MEWF1","Q_2+RSVC_MEWF1_I","Q_2+RSVC_RRSF1","Q_2+RSVC_RRSF1_I","Q_2+RSVC_RUGBYR1","Q_2+RSVC_RUGBYR1_I","Q_2+RSVC_SMCSF1","Q_2+RSVC_SMCSF1_I","Q_2+RSVC_WHITSF1","Q_2+RSVC_WHITSF1_I","T_V_NIL_FCSPS","V>>BELMLCB_BAML_TGML","V>>MLSY_GTDPT_MLSY","V>>MLSY_GTKT_MLSY","V>>MLSY_KTDPT_SYML","V>>MLSY_KTTX_SYML_2R","V>>MLSY_KTTX_SYML_5R","V>>MLSY_SHBE_SYML"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version with respect to the effective date","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADDITIONALNOTES":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Extra notes on the constraint","examples":["CCR10197","CCR10205 A50 Region 1+2 +A17.b+A17.c NQLD SSI outage advice rev30","CCR10205 A50 Region 1+2 +A17.b+A17.c NQLD SSI outage advice rev30 and WAMPAC (DS+PD only)","CCR10205 A50 Region 1+3 +A17.b+A17.c NQLD SSI outage advice rev30","CCR10205 A50 Region 1+3 +A17.b+A17.c NQLD SSI outage advice rev30 and WAMPAC (DS+PD only)","CCR10205 A50 Region 1+4 +A17.b+A17.c NQLD SSI outage advice rev30","CCR10205 A50 Region 1+4 +A17.b+A17.c NQLD SSI outage advice rev30 and WAMPAC (DS+PD only)","CCR10207 A17b NQLD SSI outage advice rev30","CCR10207 A17b NQLD SSI outage advice rev30;","CCR10207 A38a + A17b/A17c NQLD SSI outage advice rev30","CCR10207 A38a + A17b/A17c NQLD SSI outage advice rev30; WAMPAC DS+PD only","CCR10207 A38a NQLD SSI outage advice rev30;","CCR10207 A38b + A17b/A17c NQLD SSI outage advice rev30","CCR10207 A38b + A17b/A17c NQLD SSI outage advice rev30; WAMPAC DS+PD only","CCR10207 A38b NQLD SSI outage advice rev30;","CCR10207 A38c + A17b/A17c NQLD SSI outage advice rev30;","CCR10207 A38c + A17b/A17c NQLD SSI outage advice rev30; WAMPAC DS+PD only","CCR10207 A38c NQLD SSI outage advice rev30;","CCR10208 A17b NQLD SSI outage advice rev30","CCR10208 A17b/A17c NQLD SSI outage advice rev30","CCR10208 A17b/A17c NQLD SSI outage advice rev30; WAMPAC DS+PD only","CCR10209 A17b NQLD SSI outage advice rev30;","CCR10209 A9 + A17b/A17c NQLD SSI outage advice rev30","CCR10209 A9 + A17b/A17c NQLD SSI outage advice rev30; WAMPAC DS+PD only","CCR10209 A9 NQLD SSI outage advice rev30;","Contingency in VFRB Group A. CCR10204","Generated by CJD on 01-SEP-2026 08:12:52 by STNET[NORCR4] Host NORREGEEMP8(EMPSYD)","SW GFT no longer operate for both SYTS-MLTS line open. EMTT disabled. CCR10210","TasNetworks Limits Advice 10/11/23. CCR10211"]},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["ANGROOM","ANL","BATCH","BCHHETRI","BSANGHAVI","Batch","DFARQUHAR","DHARVINL","JDUQUE","JHOO","JWRIGHT","KHOUNSELL","KINW","KNGUYEN2","MBHASKAR","MYASAN","PARULS","SHENGG","SRAJAPAKSE2","WSCHIE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/09/01 02:06:54"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONSTRAINTTYPE":{"sql_type":"VARCHAR2(2)","pl_type":"pl.Categorical","mandatory":false,"comment":"The logical operator (=, >=, <=)","examples":["<=","=",">="]},"CONSTRAINTVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"the RHS value used if there is no dynamic RHS defined in GenericConstraintRHS","examples":["-0.0001","0.0001","0","10080"],"is_float":true},"DESCRIPTION":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Detail of the plant that is not in service","examples":["Allowable INV indication for Aldoga SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Broadsound SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Clare SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Collinsville SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Daydream SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Hamilton SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Haughton SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Hayman SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Kaban WF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Kennedy Energy Park; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Kidston SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Mt Emerald WF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Ross River SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Rugby Run SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Sun Metals SF; No limit = 9957.5, pause/zero = 10000","Allowable INV indication for Whitsundays SF; No limit = 9957.5, pause/zero = 10000","Allowable turbine indication for Kaban WF; No limit = 9957.5, pause/zero = 10000","Allowable turbine indication for Mt Emerald WF; No limit = 9957.5, pause/zero = 10000","Basslink limit from Tas to Vic for generation enabled for FCSPS. DS limit only.","Constraint Automation, O/L BATS_MLTS2_220:LML2:I:220@BATS@VIC for CTG LVAK on trip of MLTS-TGTS 220KV LINE.  Generated by STNET[NORCR4] Host NORREGEEMP8(EMPSYD)","DATASNAP TEST constraint - NEVER TO BIND. P1 loop RHS for testing. Physical dataset regression 2","DATASNAP TEST constraint - NEVER TO BIND. P2 loop RHS for testing. MLF synthetic dataset","Hard Ramping constraint for constraint F_I+ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_I+ML_L60_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_I+ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN++ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN++ML_L60_APD_L, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN++ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN+ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN+ML_L60_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint F_MAIN+ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Hard Ramping constraint for constraint N::N_CNCW_1, Effective Date: 30/07/2026, Version: 1","Hard Ramping constraint for constraint N::N_CNCW_2, Effective Date: 30/07/2026, Version: 1","Hard Ramping constraint for constraint N::N_DTKV_1, Effective Date: 21/05/2026, Version: 1","Hard Ramping constraint for constraint N::N_DTKV_2, Effective Date: 21/05/2026, Version: 1","Hard Ramping constraint for constraint N::V_BUDP_BWSW, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_BUDP_MSDD, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_BUDP_UTMS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_CNCW_BWSW, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_CNCW_MSDD, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_CNCW_UTMS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_DTKV_BWSW, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_DTKV_MSDD, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_DTKV_UTMS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N::V_LTWG, Effective Date: 30/06/2015, Version: 1","Hard Ramping constraint for constraint N:V_BUDP_BWRG, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N:V_BUDP_BYYS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N:V_CNCW_BWRG, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N:V_CNCW_BYYS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N:V_DTKV_BWRG, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N:V_DTKV_BYYS, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint N>96M_969_NIL, Effective Date: 21/07/2026, Version: 1","Hard Ramping constraint for constraint N>>18_03_9_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_051_67_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>18_07_03_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_07_1_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_16_8_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_1_07_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_1_6X_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_4_5_N_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_4_5_S_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_70_71_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_8_10_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_8_16_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_9_03_N_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_9_03_S_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>18_9_2_OPEN, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>25_23_22, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>25_23_31, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>29_23_22, Effective Date: 30/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_3L_3J, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_3L_3P, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_3L_5, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_4_5, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_4_61, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_61, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_70_71, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_8_10, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_8_16, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_9, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_9_03_N, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>6_9_03_S, Effective Date: 18/06/2026, Version: 1","Hard Ramping constraint for constraint N>>99D_99J_63, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>99D_99K_63, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>9HT_9HR_63, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>9W5_965_9W3_BPASS, Effective Date: 20/05/2026, Version: 1","Hard Ramping constraint for constraint N>>9W5_965_9W3_PSMAN, Effective Date: 20/05/2026, Version: 1","Hard Ramping constraint for constraint N>>9W5_96C_87, Effective Date: 02/12/2025, Version: 1","Hard Ramping constraint for constraint N>>9W7_9W2_965, Effective Date: 05/08/2026, Version: 2","Hard Ramping constraint for constraint N>>BU7012_TX6_TX8_HV, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>BU7012_TX6_TX8_LV, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>BU7012_TX7_TX8_HV, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>BU7012_TX7_TX8_LV, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_051+X5_65_66, Effective Date: 12/09/2025, Version: 1","Hard Ramping constraint for constraint N>>V_051+X5_66_65, Effective Date: 12/09/2025, Version: 1","Hard Ramping constraint for constraint N>>V_18_65_03_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_18_65_07_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_18_65_64_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_18_65_66_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_18_65_6X_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_18_66_65_OPEN, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint N>>V_X5_65_66, Effective Date: 24/03/2026, Version: 1","Hard Ramping constraint for constraint N>>V_X5_66_65, Effective Date: 24/03/2026, Version: 1","Hard Ramping constraint for constraint N^^V_BADP_1, Effective Date: 18/12/2025, Version: 1","Hard Ramping constraint for constraint N^^V_BADP_DTKV_1, Effective Date: 26/08/2026, Version: 1","Hard Ramping constraint for constraint N^^V_CNCW_1, Effective Date: 02/12/2025, Version: 1","Hard Ramping constraint for constraint N^^V_LTWG_1, Effective Date: 27/01/2026, Version: 1","Hard Ramping constraint for constraint N^^V_TRTS_BUSCB_1, Effective Date: 23/12/2025, Version: 1","Hard Ramping constraint for constraint N_AVLSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Hard Ramping constraint for constraint N_COLEASF1_FLT_50, Effective Date: 14/10/2020, Version: 1","Hard Ramping constraint for constraint N_DARLSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Hard Ramping constraint for constraint N_DARLSF_FLT_100, Effective Date: 14/10/2020, Version: 1","Hard Ramping constraint for constraint N_FINLEYSF_CAP_0, Effective Date: 26/06/2026, Version: 1","Hard Ramping constraint for constraint N_FINLEYSF_CAP_108, Effective Date: 24/06/2026, Version: 1","Hard Ramping constraint for constraint N_FINLYSF1_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint N_FINLYSF_FLT_50, Effective Date: 14/10/2020, Version: 1","Hard Ramping constraint for constraint N_LIMOSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Hard Ramping constraint for constraint N_LIMOSF21_CAP_23, Effective Date: 24/06/2026, Version: 1","Hard Ramping constraint for constraint N_STR_AVLSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_BHBESS_37_I, Effective Date: 04/02/2026, Version: 1","Hard Ramping constraint for constraint N_STR_BOMENSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_BROKENH1_0_I, Effective Date: 21/08/2024, Version: 1","Hard Ramping constraint for constraint N_STR_COLEASF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_DARLSF1_0_I, Effective Date: 16/08/2024, Version: 1","Hard Ramping constraint for constraint N_STR_DPESS_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_FINLEYSF_80_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_FINLYSF1_0_I, Effective Date: 16/08/2024, Version: 1","Hard Ramping constraint for constraint N_STR_GESF1_0_I, Effective Date: 25/03/2026, Version: 1","Hard Ramping constraint for constraint N_STR_GNNDHSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_HILLSTSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_JUNEESF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_LIMBESS1_121_I, Effective Date: 04/02/2026, Version: 1","Hard Ramping constraint for constraint N_STR_LIMOSF1_0_I, Effective Date: 21/08/2024, Version: 1","Hard Ramping constraint for constraint N_STR_LIMOSF21_11_I, Effective Date: 20/02/2026, Version: 1","Hard Ramping constraint for constraint N_STR_MOREESF1_43_I, Effective Date: 01/07/2026, Version: 1","Hard Ramping constraint for constraint N_STR_RESS1_0_I, Effective Date: 31/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_RESS2_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_SEBSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_STWF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_SUNRSF1_0_I, Effective Date: 21/08/2024, Version: 1","Hard Ramping constraint for constraint N_STR_WAGGNSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_WSTWYSF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_STR_WYASF1_0_I, Effective Date: 08/10/2024, Version: 1","Hard Ramping constraint for constraint N_URANQ11_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint N_URANQ12_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint N_URANQ13_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint N_URANQ14_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint N_WSTWYSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Hard Ramping constraint for constraint Q>>X_HATR2_HATR_HATR, Effective Date: 05/06/2026, Version: 1","Hard Ramping constraint for constraint Q>CLBTX_CLBTX_NIL, Effective Date: 05/06/2026, Version: 1","Hard Ramping constraint for constraint Q>MRTA_732, Effective Date: 30/08/2018, Version: 1","Hard Ramping constraint for constraint Q^^TR_CLHA_-050, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q^^TR_CLHA_-100, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q^^TR_CLHA_-150, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q^^TR_TRBK_-050, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q^^TR_TRBK_-200, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q^^TR_TRBK_-450, Effective Date: 12/06/2026, Version: 1","Hard Ramping constraint for constraint Q_B2PSBRA_8840, Effective Date: 21/08/2013, Version: 1","Hard Ramping constraint for constraint Q_OKTA_7246, Effective Date: 21/08/2013, Version: 1","Hard Ramping constraint for constraint S-MAPS2-PV_0, Effective Date: 09/06/2021, Version: 1","Hard Ramping constraint for constraint S-MAPS3-PV_0, Effective Date: 09/06/2021, Version: 1","Hard Ramping constraint for constraint S-MWPS1-PV_0, Effective Date: 20/10/2020, Version: 1","Hard Ramping constraint for constraint S-MWPS2-PV_0, Effective Date: 20/10/2020, Version: 1","Hard Ramping constraint for constraint S-MWPS3-PV_0, Effective Date: 20/10/2020, Version: 1","Hard Ramping constraint for constraint S::V_KHKN_TBSE_2, Effective Date: 02/02/2026, Version: 1","Hard Ramping constraint for constraint S::V_MAMO_TBSE, Effective Date: 02/02/2026, Version: 1","Hard Ramping constraint for constraint S::V_NIL_TBSE_2, Effective Date: 22/01/2026, Version: 1","Hard Ramping constraint for constraint S:VS_BLKRG_700, Effective Date: 21/05/2025, Version: 1","Hard Ramping constraint for constraint S:V_BLKRG_550, Effective Date: 12/01/2026, Version: 1","Hard Ramping constraint for constraint S>>ACMA_TBTU_TBMO, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint S>>ACMA_TBTU_TBTU, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint S>>ACMA_TUTB_TUTB, Effective Date: 14/07/2026, Version: 1","Hard Ramping constraint for constraint S>>KHKN_SETB_SETB_2, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint S>>KHKN_TBSE_TBSE_2, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint S>>KHKN_TBTX4_TBMO, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint S>>MW2MW3_NWRB1, Effective Date: 01/07/2026, Version: 1","Hard Ramping constraint for constraint S>>MW2MW3_RBNW1, Effective Date: 01/07/2026, Version: 1","Hard Ramping constraint for constraint S>>TB6536_TBTX4_TBMO, Effective Date: 11/02/2026, Version: 1","Hard Ramping constraint for constraint S>>TB6536_TBTX4_TUTB, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint S>>V_NWRB2_RBNW1, Effective Date: 21/10/2020, Version: 1","Hard Ramping constraint for constraint S>KHKN_NIL_SETX12, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint S>KHKN_SETX_SETX, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint S>KHKN_SETX_SETX1, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint SVML_-020, Effective Date: 24/02/2021, Version: 1","Hard Ramping constraint for constraint SVML_020, Effective Date: 08/01/2014, Version: 1","Hard Ramping constraint for constraint SVML_050, Effective Date: 24/02/2021, Version: 1","Hard Ramping constraint for constraint SVML_FLT_130, Effective Date: 14/10/2020, Version: 1","Hard Ramping constraint for constraint SVML_ZERO, Effective Date: 21/08/2013, Version: 1","Hard Ramping constraint for constraint S^ACMA_TBTX, Effective Date: 14/07/2026, Version: 2","Hard Ramping constraint for constraint S_DC_CBG3, Effective Date: 21/08/2013, Version: 1","Hard Ramping constraint for constraint S_MANNUMB1_GE_0_IDS, Effective Date: 05/03/2026, Version: 1","Hard Ramping constraint for constraint S_MANNUMB1_LE_0_IDS, Effective Date: 05/03/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWRO3_O1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWRO3_O2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWRO3_V1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWRO3_V2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_Q1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_Q2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_S1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_SD, Effective Date: 09/12/2025, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_V1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_HWSM_V2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_LTWG_S1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_LTWG_S2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_LTWG_SD, Effective Date: 09/12/2025, Version: 1","Hard Ramping constraint for constraint V::N_LTWG_V1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_LTWG_V2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_MLTX_O1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_MLTX_O2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_MLTX_V1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::N_MLTX_V2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V::S_BLKRG_MAXG_3, Effective Date: 02/12/2025, Version: 1","Hard Ramping constraint for constraint V::S_BLKRG_TBSE_2, Effective Date: 02/12/2025, Version: 1","Hard Ramping constraint for constraint V::S_KHKN_MAXG_2, Effective Date: 02/02/2026, Version: 1","Hard Ramping constraint for constraint V::S_KHKN_SETB_2, Effective Date: 02/02/2026, Version: 1","Hard Ramping constraint for constraint V:SS_BLKRG_790, Effective Date: 21/05/2025, Version: 1","Hard Ramping constraint for constraint V:S_BLKRG_570, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>DBL_MSDD_MSDD, Effective Date: 09/02/2026, Version: 1","Hard Ramping constraint for constraint V>>DBL_MSDD_MSDD_SIP, Effective Date: 09/02/2026, Version: 1","Hard Ramping constraint for constraint V>>DBT_DDTX1_DDTX, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>DBT_DDTX2_DDTX, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>DBT_DDTX3_DDTX, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>MLTX2_KTDPT_MLTX1, Effective Date: 05/08/2026, Version: 1","Hard Ramping constraint for constraint V>>N_051+X5_65_66, Effective Date: 12/09/2025, Version: 1","Hard Ramping constraint for constraint V>>N_051+X5_66_65, Effective Date: 12/09/2025, Version: 1","Hard Ramping constraint for constraint V>>N_X5_65_66, Effective Date: 17/03/2026, Version: 1","Hard Ramping constraint for constraint V>>N_X5_66_65, Effective Date: 17/03/2026, Version: 1","Hard Ramping constraint for constraint V>>X1_WBBA_RCX9, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_BABE_SHBE, Effective Date: 09/02/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_BEKG_CWBUHO, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_BUHO_BEKG, Effective Date: 09/02/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_KGWE_CWBUHO, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_KOKG_NIL, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_MSDD1_MSDD2, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_MSDD1_MSDD2_S, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_MSDD2_MSDD1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_MSDD2_MSDD1_S, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_SHBE_NIL, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_WBBA_KGBE, Effective Date: 09/02/2026, Version: 1","Hard Ramping constraint for constraint V>>X5_WERC_CWBUHO, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V>S_NWRB2_NWRB1, Effective Date: 21/10/2020, Version: 1","Hard Ramping constraint for constraint VSML_-020, Effective Date: 08/01/2014, Version: 1","Hard Ramping constraint for constraint VSML_020, Effective Date: 08/01/2014, Version: 1","Hard Ramping constraint for constraint VSML_050, Effective Date: 24/02/2021, Version: 1","Hard Ramping constraint for constraint VSML_ZERO, Effective Date: 21/08/2013, Version: 1","Hard Ramping constraint for constraint V^SML_BUDP_3, Effective Date: 04/11/2024, Version: 1","Hard Ramping constraint for constraint V^S_HYCP_SC_OS, Effective Date: 25/07/2016, Version: 1","Hard Ramping constraint for constraint V^^N_BADP_1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V^^N_BADP_DTKV_1, Effective Date: 26/08/2026, Version: 1","Hard Ramping constraint for constraint V^^N_CNCW_1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V^^N_DTKV_1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V^^N_HWSM_1, Effective Date: 04/07/2026, Version: 1","Hard Ramping constraint for constraint V^^S_BLKRG_MAXG_3, Effective Date: 02/12/2025, Version: 1","Hard Ramping constraint for constraint V^^S_BLKRG_TBSE_2, Effective Date: 23/04/2025, Version: 1","Hard Ramping constraint for constraint V^^S_KHKN_MAXG_2, Effective Date: 02/02/2026, Version: 1","Hard Ramping constraint for constraint V^^S_KHKN_SETB_2, Effective Date: 05/12/2024, Version: 1","Hard Ramping constraint for constraint V_BANNERTSF_FLT_45, Effective Date: 19/07/2019, Version: 1","Hard Ramping constraint for constraint V_BGWF_BESS_FLT_100, Effective Date: 18/03/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_BANN1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_CRWARP_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_KARSF1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_KIAMAL_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_WEMEN_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_BURC_YATSF1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Hard Ramping constraint for constraint V_CRWARP_FLT_75, Effective Date: 18/03/2026, Version: 1","Hard Ramping constraint for constraint V_GANWRSF_FLT_30, Effective Date: 19/07/2019, Version: 1","Hard Ramping constraint for constraint V_HD_RYC_MAC_750, Effective Date: 13/05/2026, Version: 1","Hard Ramping constraint for constraint V_HM_VIC_ZERO, Effective Date: 19/01/2024, Version: 1","Hard Ramping constraint for constraint V_KARADSF_FLT_25, Effective Date: 29/08/2019, Version: 1","Hard Ramping constraint for constraint V_KIAMSF_FLT_100, Effective Date: 18/03/2026, Version: 1","Hard Ramping constraint for constraint V_LAVNTH1_ZERO, Effective Date: 01/07/2015, Version: 1","Hard Ramping constraint for constraint V_MURRAWRWF_FLT_200, Effective Date: 18/03/2026, Version: 1","Hard Ramping constraint for constraint V_WEMENSF_FLT_45, Effective Date: 19/07/2019, Version: 1","Hard Ramping constraint for constraint V_YATPSF_FLT_25, Effective Date: 14/10/2020, Version: 1","Limit Aldoga SF to 100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Aldoga SF to 80% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Aldoga SF to100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Aldoga SF to100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Broadsound SF to 80% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Clare SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Clare SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Collinsville SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Daydream SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hamilton SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Haughton SF to 100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Haughton SF to100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton  Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Haughton SF to100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Haughton SF to100% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Hayman SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Hayman SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to 100%, 80%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to 100%, 80%, 60%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to 100%,80%, 25%,15%,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to 80%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to 80%, 70%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to100%,80%, 70%,25%,15%,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kaban WF to100%,80%,25%,15%,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kennedy Energy Park to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kennedy Energy Park to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand; Zero if it does not meet the condition","Limit Kidston SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Kidston SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to 100%, 80%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to 100%, 80%, 60%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to 100%,80%, 25%,15%,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to 80%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to 80%, 70%, 25%, 15%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to100%,80%, 70%,25%,15%,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Mt Emerald WF to100%,80%,25%,15% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Ross River SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Rugby Run SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Sun Metals SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to 100%, 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to 100%, 80%, 60%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to 80%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to 80%, 70%, 40%, 30%, 20%, 1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to100%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to100%,70%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Limit Whitsundays SF to100%,80%,40%,30%,20% ,1% dependent on status of Stanwell, Callide B+C, Gladstone, Kareeya, Haughton/Townsville Syncon, NQLD demand, Ross+FNQ demand, NQLD WAMPAC; Zero if it does not meet the condition","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 1/09/2026 12:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 4/09/2026 8:35:00 AM","Out = Moorabool to Sydenham 500 kV line, Emergency Moorabool Transformer Tripping (EMTT) scheme disabled, avoid O/L Keilor to Deer Park 220 kV line on trip of remaining Moorabool to Sydenham 500 kV line, feedback","Out = One Moorabool to Sydenham 500 kV line, Emergency Moorabool Transformer Tripping (EMTT) scheme disabled, avoid overloading Shepparton to Fosterville to Bendigo 220 kV line on trip of the remaining MLTS-SYTS 500 kV line, feedback","Out = One Moorabool to Sydenham 500 kV line, Emergency Moorabool Transformer Tripping (EMTT) scheme disabled, prevent overload of the Keilor A2 or A4 500/220 kV txfmr on trip of the remaining MLTS-SYTS 500 kV line, radial mode, YWG1 on 220 kV, feedback","Out = One Moorabool to Sydenham 500 kV line, Emergency Moorabool Transformer Tripping (EMTT) scheme disabled, prevent overload of the Keilor A2 or A4 500/220 kV txfmr on trip of the remaining MLTS-SYTS 500 kV line, radial mode, YWG1 on 500 kV, feedback","Out= Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool, avoid O/L Ballarat to Moorabool No.2 220kV line on trip of Terang to Moorabool 220kV line offloading Ballarat to Moorabool No.1 line, Feedback","Out= Moorabool to Sydenham 500kV line, avoid O/L Geelong to Deer Park 220kV line on trip of the remaining Moorabool to Sydenham 500kV line, Feedback","Out= Moorabool to Sydenham 500kV line, avoid O/L Geelong to Keilor No.1 or No.3 220kV line on trip of the remaining Moorabool to Sydenham 500kV line, Feedback","SDCA1.ENERGY * 1 = 20 (Wt = 755)","SDCA2.ENERGY * 1 = 20 (Wt = 755)","STSB4.ENERGY * 1 = 40 (Wt = 755)","Soft Ramping constraint for constraint F_I+ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_I+ML_L60_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_I+ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN++ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN++ML_L60_APD_L, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN++ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN+ML_L5_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN+ML_L60_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint F_MAIN+ML_L6_APD_LD, Effective Date: 11/12/2019, Version: 2","Soft Ramping constraint for constraint N::N_CNCW_1, Effective Date: 30/07/2026, Version: 1","Soft Ramping constraint for constraint N::N_CNCW_2, Effective Date: 30/07/2026, Version: 1","Soft Ramping constraint for constraint N::N_DTKV_1, Effective Date: 21/05/2026, Version: 1","Soft Ramping constraint for constraint N::N_DTKV_2, Effective Date: 21/05/2026, Version: 1","Soft Ramping constraint for constraint N::V_BUDP_BWSW, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_BUDP_MSDD, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_BUDP_UTMS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_CNCW_BWSW, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_CNCW_MSDD, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_CNCW_UTMS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_DTKV_BWSW, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_DTKV_MSDD, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_DTKV_UTMS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N::V_LTWG, Effective Date: 30/06/2015, Version: 1","Soft Ramping constraint for constraint N:V_BUDP_BWRG, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N:V_BUDP_BYYS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N:V_CNCW_BWRG, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N:V_CNCW_BYYS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N:V_DTKV_BWRG, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N:V_DTKV_BYYS, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint N>96M_969_NIL, Effective Date: 21/07/2026, Version: 1","Soft Ramping constraint for constraint N>>18_03_9_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_051_67_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>18_07_03_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_07_1_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_16_8_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_1_07_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_1_6X_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_4_5_N_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_4_5_S_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_70_71_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_8_10_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_8_16_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_9_03_N_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_9_03_S_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>18_9_2_OPEN, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>25_23_22, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>25_23_31, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>29_23_22, Effective Date: 30/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_3L_3J, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_3L_3P, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_3L_5, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_4_5, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_4_61, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_61, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_70_71, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_8_10, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_8_16, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_9, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_9_03_N, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>6_9_03_S, Effective Date: 18/06/2026, Version: 1","Soft Ramping constraint for constraint N>>99D_99J_63, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>99D_99K_63, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>9HT_9HR_63, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>9W5_965_9W3_BPASS, Effective Date: 20/05/2026, Version: 1","Soft Ramping constraint for constraint N>>9W5_965_9W3_PSMAN, Effective Date: 20/05/2026, Version: 1","Soft Ramping constraint for constraint N>>9W5_96C_87, Effective Date: 02/12/2025, Version: 1","Soft Ramping constraint for constraint N>>9W7_9W2_965, Effective Date: 05/08/2026, Version: 2","Soft Ramping constraint for constraint N>>BU7012_TX6_TX8_HV, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>BU7012_TX6_TX8_LV, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>BU7012_TX7_TX8_HV, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>BU7012_TX7_TX8_LV, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_051+X5_65_66, Effective Date: 12/09/2025, Version: 1","Soft Ramping constraint for constraint N>>V_051+X5_66_65, Effective Date: 12/09/2025, Version: 1","Soft Ramping constraint for constraint N>>V_18_65_03_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_18_65_07_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_18_65_64_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_18_65_66_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_18_65_6X_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_18_66_65_OPEN, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint N>>V_X5_65_66, Effective Date: 24/03/2026, Version: 1","Soft Ramping constraint for constraint N>>V_X5_66_65, Effective Date: 24/03/2026, Version: 1","Soft Ramping constraint for constraint N^^V_BADP_1, Effective Date: 18/12/2025, Version: 1","Soft Ramping constraint for constraint N^^V_BADP_DTKV_1, Effective Date: 26/08/2026, Version: 1","Soft Ramping constraint for constraint N^^V_CNCW_1, Effective Date: 02/12/2025, Version: 1","Soft Ramping constraint for constraint N^^V_LTWG_1, Effective Date: 27/01/2026, Version: 1","Soft Ramping constraint for constraint N^^V_TRTS_BUSCB_1, Effective Date: 23/12/2025, Version: 1","Soft Ramping constraint for constraint N_AVLSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Soft Ramping constraint for constraint N_COLEASF1_FLT_50, Effective Date: 14/10/2020, Version: 1","Soft Ramping constraint for constraint N_DARLSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Soft Ramping constraint for constraint N_DARLSF_FLT_100, Effective Date: 14/10/2020, Version: 1","Soft Ramping constraint for constraint N_FINLEYSF_CAP_0, Effective Date: 26/06/2026, Version: 1","Soft Ramping constraint for constraint N_FINLEYSF_CAP_108, Effective Date: 24/06/2026, Version: 1","Soft Ramping constraint for constraint N_FINLYSF1_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint N_FINLYSF_FLT_50, Effective Date: 14/10/2020, Version: 1","Soft Ramping constraint for constraint N_LIMOSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Soft Ramping constraint for constraint N_LIMOSF21_CAP_23, Effective Date: 24/06/2026, Version: 1","Soft Ramping constraint for constraint N_STR_AVLSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_BHBESS_37_I, Effective Date: 04/02/2026, Version: 1","Soft Ramping constraint for constraint N_STR_BOMENSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_BROKENH1_0_I, Effective Date: 21/08/2024, Version: 1","Soft Ramping constraint for constraint N_STR_COLEASF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_DARLSF1_0_I, Effective Date: 16/08/2024, Version: 1","Soft Ramping constraint for constraint N_STR_DPESS_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_FINLEYSF_80_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_FINLYSF1_0_I, Effective Date: 16/08/2024, Version: 1","Soft Ramping constraint for constraint N_STR_GESF1_0_I, Effective Date: 25/03/2026, Version: 1","Soft Ramping constraint for constraint N_STR_GNNDHSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_HILLSTSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_JUNEESF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_LIMBESS1_121_I, Effective Date: 04/02/2026, Version: 1","Soft Ramping constraint for constraint N_STR_LIMOSF1_0_I, Effective Date: 21/08/2024, Version: 1","Soft Ramping constraint for constraint N_STR_LIMOSF21_11_I, Effective Date: 20/02/2026, Version: 1","Soft Ramping constraint for constraint N_STR_MOREESF1_43_I, Effective Date: 01/07/2026, Version: 1","Soft Ramping constraint for constraint N_STR_RESS1_0_I, Effective Date: 31/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_RESS2_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_SEBSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_STWF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_SUNRSF1_0_I, Effective Date: 21/08/2024, Version: 1","Soft Ramping constraint for constraint N_STR_WAGGNSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_WSTWYSF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_STR_WYASF1_0_I, Effective Date: 08/10/2024, Version: 1","Soft Ramping constraint for constraint N_URANQ11_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint N_URANQ12_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint N_URANQ13_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint N_URANQ14_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint N_WSTWYSF1_CAP_0, Effective Date: 26/06/2026, Version: 1","Soft Ramping constraint for constraint Q>>X_HATR2_HATR_HATR, Effective Date: 05/06/2026, Version: 1","Soft Ramping constraint for constraint Q>CLBTX_CLBTX_NIL, Effective Date: 05/06/2026, Version: 1","Soft Ramping constraint for constraint Q>MRTA_732, Effective Date: 30/08/2018, Version: 1","Soft Ramping constraint for constraint Q^^TR_CLHA_-050, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q^^TR_CLHA_-100, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q^^TR_CLHA_-150, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q^^TR_TRBK_-050, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q^^TR_TRBK_-200, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q^^TR_TRBK_-450, Effective Date: 12/06/2026, Version: 1","Soft Ramping constraint for constraint Q_B2PSBRA_8840, Effective Date: 21/08/2013, Version: 1","Soft Ramping constraint for constraint Q_OKTA_7246, Effective Date: 21/08/2013, Version: 1","Soft Ramping constraint for constraint S-MAPS2-PV_0, Effective Date: 09/06/2021, Version: 1","Soft Ramping constraint for constraint S-MAPS3-PV_0, Effective Date: 09/06/2021, Version: 1","Soft Ramping constraint for constraint S-MWPS1-PV_0, Effective Date: 20/10/2020, Version: 1","Soft Ramping constraint for constraint S-MWPS2-PV_0, Effective Date: 20/10/2020, Version: 1","Soft Ramping constraint for constraint S-MWPS3-PV_0, Effective Date: 20/10/2020, Version: 1","Soft Ramping constraint for constraint S::V_KHKN_TBSE_2, Effective Date: 02/02/2026, Version: 1","Soft Ramping constraint for constraint S::V_MAMO_TBSE, Effective Date: 02/02/2026, Version: 1","Soft Ramping constraint for constraint S::V_NIL_TBSE_2, Effective Date: 22/01/2026, Version: 1","Soft Ramping constraint for constraint S:VS_BLKRG_700, Effective Date: 21/05/2025, Version: 1","Soft Ramping constraint for constraint S:V_BLKRG_550, Effective Date: 12/01/2026, Version: 1","Soft Ramping constraint for constraint S>>ACMA_TBTU_TBMO, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint S>>ACMA_TBTU_TBTU, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint S>>ACMA_TUTB_TUTB, Effective Date: 14/07/2026, Version: 1","Soft Ramping constraint for constraint S>>KHKN_SETB_SETB_2, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint S>>KHKN_TBSE_TBSE_2, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint S>>KHKN_TBTX4_TBMO, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint S>>MW2MW3_NWRB1, Effective Date: 01/07/2026, Version: 1","Soft Ramping constraint for constraint S>>MW2MW3_RBNW1, Effective Date: 01/07/2026, Version: 1","Soft Ramping constraint for constraint S>>TB6536_TBTX4_TBMO, Effective Date: 11/02/2026, Version: 1","Soft Ramping constraint for constraint S>>TB6536_TBTX4_TUTB, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint S>>V_NWRB2_RBNW1, Effective Date: 21/10/2020, Version: 1","Soft Ramping constraint for constraint S>KHKN_NIL_SETX12, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint S>KHKN_SETX_SETX, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint S>KHKN_SETX_SETX1, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint SVML_-020, Effective Date: 24/02/2021, Version: 1","Soft Ramping constraint for constraint SVML_020, Effective Date: 08/01/2014, Version: 1","Soft Ramping constraint for constraint SVML_050, Effective Date: 24/02/2021, Version: 1","Soft Ramping constraint for constraint SVML_FLT_130, Effective Date: 14/10/2020, Version: 1","Soft Ramping constraint for constraint SVML_ZERO, Effective Date: 21/08/2013, Version: 1","Soft Ramping constraint for constraint S^ACMA_TBTX, Effective Date: 14/07/2026, Version: 2","Soft Ramping constraint for constraint S_DC_CBG3, Effective Date: 21/08/2013, Version: 1","Soft Ramping constraint for constraint S_MANNUMB1_GE_0_IDS, Effective Date: 05/03/2026, Version: 1","Soft Ramping constraint for constraint S_MANNUMB1_LE_0_IDS, Effective Date: 05/03/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWRO3_O1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWRO3_O2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWRO3_V1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWRO3_V2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_Q1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_Q2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_S1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_SD, Effective Date: 09/12/2025, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_V1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_HWSM_V2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_LTWG_S1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_LTWG_S2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_LTWG_SD, Effective Date: 09/12/2025, Version: 1","Soft Ramping constraint for constraint V::N_LTWG_V1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_LTWG_V2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_MLTX_O1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_MLTX_O2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_MLTX_V1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::N_MLTX_V2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V::S_BLKRG_MAXG_3, Effective Date: 02/12/2025, Version: 1","Soft Ramping constraint for constraint V::S_BLKRG_TBSE_2, Effective Date: 02/12/2025, Version: 1","Soft Ramping constraint for constraint V::S_KHKN_MAXG_2, Effective Date: 02/02/2026, Version: 1","Soft Ramping constraint for constraint V::S_KHKN_SETB_2, Effective Date: 02/02/2026, Version: 1","Soft Ramping constraint for constraint V:SS_BLKRG_790, Effective Date: 21/05/2025, Version: 1","Soft Ramping constraint for constraint V:S_BLKRG_570, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>DBL_MSDD_MSDD, Effective Date: 09/02/2026, Version: 1","Soft Ramping constraint for constraint V>>DBL_MSDD_MSDD_SIP, Effective Date: 09/02/2026, Version: 1","Soft Ramping constraint for constraint V>>DBT_DDTX1_DDTX, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>DBT_DDTX2_DDTX, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>DBT_DDTX3_DDTX, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>MLTX2_KTDPT_MLTX1, Effective Date: 05/08/2026, Version: 1","Soft Ramping constraint for constraint V>>N_051+X5_65_66, Effective Date: 12/09/2025, Version: 1","Soft Ramping constraint for constraint V>>N_051+X5_66_65, Effective Date: 12/09/2025, Version: 1","Soft Ramping constraint for constraint V>>N_X5_65_66, Effective Date: 17/03/2026, Version: 1","Soft Ramping constraint for constraint V>>N_X5_66_65, Effective Date: 17/03/2026, Version: 1","Soft Ramping constraint for constraint V>>X1_WBBA_RCX9, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_BABE_SHBE, Effective Date: 09/02/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_BEKG_CWBUHO, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_BUHO_BEKG, Effective Date: 09/02/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_KGWE_CWBUHO, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_KOKG_NIL, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_MSDD1_MSDD2, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_MSDD1_MSDD2_S, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_MSDD2_MSDD1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_MSDD2_MSDD1_S, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_SHBE_NIL, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_WBBA_KGBE, Effective Date: 09/02/2026, Version: 1","Soft Ramping constraint for constraint V>>X5_WERC_CWBUHO, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V>S_NWRB2_NWRB1, Effective Date: 21/10/2020, Version: 1","Soft Ramping constraint for constraint VSML_-020, Effective Date: 08/01/2014, Version: 1","Soft Ramping constraint for constraint VSML_020, Effective Date: 08/01/2014, Version: 1","Soft Ramping constraint for constraint VSML_050, Effective Date: 24/02/2021, Version: 1","Soft Ramping constraint for constraint VSML_ZERO, Effective Date: 21/08/2013, Version: 1","Soft Ramping constraint for constraint V^SML_BUDP_3, Effective Date: 04/11/2024, Version: 1","Soft Ramping constraint for constraint V^S_HYCP_SC_OS, Effective Date: 25/07/2016, Version: 1","Soft Ramping constraint for constraint V^^N_BADP_1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V^^N_BADP_DTKV_1, Effective Date: 26/08/2026, Version: 1","Soft Ramping constraint for constraint V^^N_CNCW_1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V^^N_DTKV_1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V^^N_HWSM_1, Effective Date: 04/07/2026, Version: 1","Soft Ramping constraint for constraint V^^S_BLKRG_MAXG_3, Effective Date: 02/12/2025, Version: 1","Soft Ramping constraint for constraint V^^S_BLKRG_TBSE_2, Effective Date: 23/04/2025, Version: 1","Soft Ramping constraint for constraint V^^S_KHKN_MAXG_2, Effective Date: 02/02/2026, Version: 1","Soft Ramping constraint for constraint V^^S_KHKN_SETB_2, Effective Date: 05/12/2024, Version: 1","Soft Ramping constraint for constraint V_BANNERTSF_FLT_45, Effective Date: 19/07/2019, Version: 1","Soft Ramping constraint for constraint V_BGWF_BESS_FLT_100, Effective Date: 18/03/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_BANN1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_CRWARP_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_KARSF1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_KIAMAL_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_WEMEN_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_BURC_YATSF1_SC_DYN, Effective Date: 13/07/2026, Version: 1","Soft Ramping constraint for constraint V_CRWARP_FLT_75, Effective Date: 18/03/2026, Version: 1","Soft Ramping constraint for constraint V_GANWRSF_FLT_30, Effective Date: 19/07/2019, Version: 1","Soft Ramping constraint for constraint V_HD_RYC_MAC_750, Effective Date: 13/05/2026, Version: 1","Soft Ramping constraint for constraint V_HM_VIC_ZERO, Effective Date: 19/01/2024, Version: 1","Soft Ramping constraint for constraint V_KARADSF_FLT_25, Effective Date: 29/08/2019, Version: 1","Soft Ramping constraint for constraint V_KIAMSF_FLT_100, Effective Date: 18/03/2026, Version: 1","Soft Ramping constraint for constraint V_LAVNTH1_ZERO, Effective Date: 01/07/2015, Version: 1","Soft Ramping constraint for constraint V_MURRAWRWF_FLT_200, Effective Date: 18/03/2026, Version: 1","Soft Ramping constraint for constraint V_WEMENSF_FLT_45, Effective Date: 19/07/2019, Version: 1","Soft Ramping constraint for constraint V_YATPSF_FLT_25, Effective Date: 14/10/2020, Version: 1"]},"DISPATCH":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag: constraint RHS used for Dispatch? 1-used, 0-not used","examples":["1"],"is_boolean":true},"FORCE_SCADA":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flags Constraints for which NEMDE must use \"InitialMW\" values instead of \"WhatOfInitialMW\" for Intervention Pricing runs","examples":["0","1"],"is_boolean":true},"GENERICCONSTRAINTWEIGHT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The constraint violation penalty factor","examples":["0.0002","1","0.00836206896551724","755"],"is_float":true},"IMPACT":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"The device(s) that is affected by the constraint e.g. Interconnector, Generator(s) or Cutset","examples":["Basslink","DEFAULT","Murraylink","NSW Generation","NSW Generation + Interconnectors","Other","Qld Generation","Qld Generation + Interconnectors","SA Generation","SA Generation + Interconnectors","Tarong Limit","Vic - NSW Interconnector","Vic - NSW Interconnector + Generators","Vic - SA (Heywood) Interconnector","Vic - SA (Heywood) Interconnector + Murraylink","Victorian Generation","Victorian Generation + Interconnectors"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true},"LIMITTYPE":{"sql_type":"VARCHAR2(64)","pl_type":"pl.Categorical","mandatory":false,"comment":"The limit type of the constraint e.g. Transient Stability, Voltage Stability","examples":["DEFAULT","Discretionary","FCAS","Interconnector Zero","Oscillatory Stability","Other","System Strength","Thermal","Transient Stability","Unit Zero","Voltage Stability"]},"LOR":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if PASA LOR run uses the constraint; 1-used, 0-not used","examples":["0","1"],"is_boolean":true},"LRC":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if PASA LRC run uses the constraint; 1-used, 0-not used","examples":["0","1"],"is_boolean":true},"MODIFICATIONS":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Details of the changes made to this version of the constraint","examples":["Added Pine Lodge BESS","NEW","New","Remove PD scope. Limit calc accurate for DS only, avoid artificially low limits in PD."]},"MTPASA":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the constraint RHS is to be used for MT PASA, 1-used, 0-not used","examples":["0","1"],"is_boolean":true},"P5MIN_SCOPE_OVERRIDE":{"sql_type":"VARCHAR2(2)","pl_type":"str","mandatory":false,"comment":"Extra notes on the constraint: NULL = Dispatch RHS applied in 5MPD, PD = PreDispatch RHS applied in 5MPD","examples":["PD"]},"PREDISPATCH":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the constraint RHS is to be used for PreDispatch, 1-used, 0-not used","examples":["0","1"],"is_boolean":true},"REASON":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"The contingency or reason for the constraint","examples":["Avoid O/L Ballarat to Moorabool No.2 220kV line on trip of Terang to Moorabool 220kV line offloading Ballarat to Moorabool No.1 220kV line","Avoid overload of Keilor to Deer Park 220 kV line on trip of remaining Moorabool to Sydenham 500 kV line","Basslink limit for FCSPS generation enabled","DEFAULT","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Aldoga SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Clare SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Collinsville SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Daydream SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Hamilton SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Haughton SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Hayman SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Kaban WF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Kidston SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Ross River SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Rugby Run SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Sun Metals SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; Constrain Whitsundays SF generation based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Clare SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out =  2 series FNQ+ FDR 820/834/8847/8846/ 275kV bus at Broadsound or Nebo or Stanwell; To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ + 821 (H10 Bouldercombe - H11 Nebo); To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate turbine availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ + 8859 (H58 Larcom Creek - H67 Calliope River); To indicate turbine availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ + H13 Ross SVC; To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Broadsound SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Broadsound SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ + one/both 811+8875 (H10 Bouldercombe - H73 Raglan - H58 Larcom Creek); To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 848/849/855/8873/8874/871/ 818/812/Calvale 275kV Bus; To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Aldoga SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Clare SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Collinsville SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Daydream SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Hamilton SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Haughton SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Hayman SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Kaban WF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Kidston SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Ross River SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Aldoga SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = 2 series FNQ+ FDR 8845/878/822/8857/8858/ (8911+879)/275kV bus at Ross or Strathmore; To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Clare SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Collinsville SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Daydream SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Hamilton SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Haughton SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Hayman SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Kaban WF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Kennedy Energy Park generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Kidston SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Mt Emerald WF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Ross River SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Rugby Run SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Sun Metals SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; Constrain Whitsundays SF generation based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Clare SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Collinsville SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Daydream SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Hamilton SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Haughton SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Hayman SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Kaban WF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Kennedy Energy Park based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Kidston SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Mt Emerald WF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Ross River SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Rugby Run SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Sun Metals SF based on NQLD system strength requirements","Out = <=2 non-parallel 275kV lines between Ross-Woree, <=3 non-parallel 275kV lines between Calvale-Ross, Ross SVC; To indicate INV availability for Whitsundays SF based on NQLD system strength requirements","Prevent overload of the Bendigo to Shepparton 220 kV line for trip of the remaining MLTS-SYTS 500 kV line","Prevent overload of the Keilor A2 or A4 txfmr for trip of the remaining MLTS-SYTS 500 kV line","Ramping","Required to provide system security for SSM Contract","TEST constraint, never to bind","Trip of MLTS-TGTS 220KV LINE","Trip of remaining Moorabool to Sydenham 500kV line"]},"SOURCE":{"sql_type":"VARCHAR2(128)","pl_type":"str","mandatory":false,"comment":"The source of the constraint formulation","examples":["AEMO","Constraint Automation","DEFAULT","NEMMCO","Powerlink"]},"SSM_GROUPID":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Related constraints processed together in optimiser."},"SSM_REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Region constraint relates to, in the format <REGIONID>_xxxx where xxxx is descriptive text"},"STPASA":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the constraint RHS is to be used for ST PASA, 1-used, 0-not used","examples":["0","1"],"is_boolean":true},"SYSTEMSECURITY":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flags constraint is used in System Security Management (SSM) processes. 1-Used(in SSM only),0-not used","is_boolean":true},"DYNAMICRHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","examples":["0","1","49"],"unused":true,"is_float":true},"STATUS":{"sql_type":"VARCHAR2(8)","pl_type":"str","mandatory":false,"comment":"Not used","unused":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENCONDATA%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":158896,"decompressed_size_all_time":169897110},"visibility":"Public","trigger":"Dispatch run"},"GENCONSET":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENCONSET","REPORT_SUB_TYPE":"NULL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#18"],"comment":"GENCONSET sets out generic constraint sets that are invoked and revoked, and may contain many generic constraints (GENCONDATA).","description":"GENCONSET is public data, and is available to all participants.\n\nSource\n\nGENCONSET updates as sets are updated by AEMO.","primary_keys":["EFFECTIVEDATE","GENCONID","GENCONSETID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date this record becomes effective","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Contraint ID","examples":["#DRYCGT1_D_E","#DRYCGT2_D_E","#R036713_001_RAMP_F","#R036713_001_RAMP_V","#R036714_001_RAMP_F","#R036714_001_RAMP_V","#R036715_001_RAMP_F","#R036715_001_RAMP_V","#R036715_002_RAMP_F","#R036715_002_RAMP_V","#R036715_003_RAMP_F","#R036715_003_RAMP_V","#R036716_001_RAMP_F","#R036716_001_RAMP_V","#R036717_001_RAMP_F","#R036717_001_RAMP_V","#R036717_002_RAMP_F","#R036717_002_RAMP_V","#R036717_003_RAMP_F","#R036717_003_RAMP_V","#R036717_004_RAMP_F","#R036717_004_RAMP_V","#R036717_005_RAMP_F","#R036717_005_RAMP_V","#R036718_001_RAMP_F","#R036718_001_RAMP_V","#R036718_002_RAMP_F","#R036718_002_RAMP_V","#R036718_003_RAMP_F","#R036718_003_RAMP_V","#R036718_004_RAMP_F","#R036718_004_RAMP_V","#R036718_005_RAMP_F","#R036718_005_RAMP_V","#R036718_006_RAMP_F","#R036718_006_RAMP_V","#R036718_007_RAMP_F","#R036718_007_RAMP_V","#R036719_001_RAMP_F","#R036719_001_RAMP_V","#R036719_002_RAMP_F","#R036719_002_RAMP_V","#R036719_003_RAMP_F","#R036719_003_RAMP_V","#R036719_004_RAMP_F","#R036719_004_RAMP_V","#R036719_005_RAMP_F","#R036719_005_RAMP_V","#R036719_006_RAMP_F","#R036719_006_RAMP_V","#R036719_007_RAMP_F","#R036719_007_RAMP_V","#R036720_001_RAMP_F","#R036720_001_RAMP_V","#R036720_002_RAMP_F","#R036720_002_RAMP_V","#R036720_003_RAMP_F","#R036720_003_RAMP_V","#R036720_004_RAMP_F","#R036720_004_RAMP_V","#R036721_001_RAMP_F","#R036721_001_RAMP_V","#R036721_002_RAMP_F","#R036721_002_RAMP_V","#R036721_003_RAMP_F","#R036721_003_RAMP_V","#R036721_004_RAMP_F","#R036721_004_RAMP_V","#R036721_005_RAMP_F","#R036721_005_RAMP_V","#R036721_006_RAMP_F","#R036721_006_RAMP_V","#R036721_007_RAMP_F","#R036721_007_RAMP_V","#R036721_008_RAMP_F","#R036721_008_RAMP_V","#R036721_009_RAMP_F","#R036721_009_RAMP_V","#R036721_010_RAMP_F","#R036721_010_RAMP_V","#R036721_011_RAMP_F","#R036721_011_RAMP_V","#R036721_012_RAMP_F","#R036721_012_RAMP_V","#R036721_013_RAMP_F","#R036721_013_RAMP_V","#R036721_014_RAMP_F","#R036721_014_RAMP_V","#R036721_015_RAMP_F","#R036721_015_RAMP_V","#R036721_016_RAMP_F","#R036721_016_RAMP_V","#R036721_017_RAMP_F","#R036721_017_RAMP_V","#R036721_018_RAMP_F","#R036721_018_RAMP_V","#R036721_019_RAMP_F","#R036721_019_RAMP_V","#R036721_020_RAMP_F","#R036721_020_RAMP_V","#R036721_021_RAMP_F","#R036721_021_RAMP_V","#R036722_001_RAMP_F","#R036722_001_RAMP_V","#R036722_002_RAMP_F","#R036722_002_RAMP_V","#R036722_003_RAMP_F","#R036722_003_RAMP_V","#R036722_004_RAMP_F","#R036722_004_RAMP_V","#R036723_001_RAMP_F","#R036723_001_RAMP_V","#R036723_002_RAMP_F","#R036723_002_RAMP_V","#R036724_001_RAMP_F","#R036724_001_RAMP_V","#R036725_001_RAMP_F","#R036725_001_RAMP_V","#R036725_002_RAMP_F","#R036725_002_RAMP_V","#R036725_003_RAMP_F","#R036725_003_RAMP_V","#R036725_004_RAMP_F","#R036725_004_RAMP_V","#R036725_005_RAMP_F","#R036725_005_RAMP_V","#R036725_006_RAMP_F","#R036725_006_RAMP_V","#R036725_007_RAMP_F","#R036725_007_RAMP_V","#R036725_008_RAMP_F","#R036725_008_RAMP_V","#R036725_009_RAMP_F","#R036725_009_RAMP_V","#R036726_001_RAMP_F","#R036726_001_RAMP_V","#R036727_001_RAMP_F","#R036727_001_RAMP_V","#R036728_001_RAMP_F","#R036728_001_RAMP_V","#R036728_002_RAMP_F","#R036728_002_RAMP_V","#R036729_001_RAMP_F","#R036729_001_RAMP_V","#R036729_002_RAMP_F","#R036729_002_RAMP_V","#R036730_001_RAMP_F","#R036730_001_RAMP_V","#R036731_001_RAMP_F","#R036731_001_RAMP_V","#R036731_002_RAMP_F","#R036731_002_RAMP_V","#R036731_003_RAMP_F","#R036731_003_RAMP_V","#R036731_004_RAMP_F","#R036731_004_RAMP_V","#R036731_005_RAMP_F","#R036731_005_RAMP_V","#R036731_006_RAMP_F","#R036731_006_RAMP_V","#R036731_007_RAMP_F","#R036731_007_RAMP_V","#R036731_008_RAMP_F","#R036731_008_RAMP_V","#R036731_009_RAMP_F","#R036731_009_RAMP_V","#R036732_001_RAMP_F","#R036732_001_RAMP_V","#R036732_002_RAMP_F","#R036732_002_RAMP_V","#R036732_003_RAMP_F","#R036732_003_RAMP_V","#R036732_004_RAMP_F","#R036732_004_RAMP_V","#R036732_005_RAMP_F","#R036732_005_RAMP_V","#R036733_001_RAMP_F","#R036733_001_RAMP_V","#R036733_002_RAMP_F","#R036733_002_RAMP_V","#R036734_001_RAMP_F","#R036734_001_RAMP_V","#R036734_002_RAMP_F","#R036734_002_RAMP_V","#R036735_001_RAMP_F","#R036735_001_RAMP_V","#R036735_002_RAMP_F","#R036735_002_RAMP_V","#R036736_001_RAMP_F","#R036736_001_RAMP_V","#R036736_002_RAMP_F","#R036736_002_RAMP_V","#R036737_001_RAMP_F","#R036737_001_RAMP_V","#R036737_002_RAMP_F","#R036737_002_RAMP_V","#R036738_001_RAMP_F","#R036738_001_RAMP_V","#R036738_002_RAMP_F","#R036738_002_RAMP_V","#R036739_001_RAMP_F","#R036739_001_RAMP_V","#R036740_001_RAMP_F","#R036740_001_RAMP_V","#R036741_001_RAMP_F","#R036741_001_RAMP_V","#R036741_002_RAMP_F","#R036741_002_RAMP_V","#R036742_001_RAMP_F","#R036742_001_RAMP_V","#R036742_002_RAMP_F","#R036742_002_RAMP_V","#R036743_001_RAMP_F","#R036743_001_RAMP_V","#R036743_002_RAMP_F","#R036743_002_RAMP_V","#R036744_001_RAMP_F","#R036744_001_RAMP_V","#R036744_002_RAMP_F","#R036744_002_RAMP_V","#R036745_001_RAMP_F","#R036745_001_RAMP_V","#R036745_002_RAMP_F","#R036745_002_RAMP_V","#R036746_001_RAMP_F","#R036746_001_RAMP_V","#R036746_002_RAMP_F","#R036746_002_RAMP_V","#R036747_001_RAMP_F","#R036747_001_RAMP_V","#R036747_002_RAMP_F","#R036747_002_RAMP_V","#R036748_001_RAMP_F","#R036748_001_RAMP_V","#R036748_002_RAMP_F","#R036748_002_RAMP_V","#R036749_001_RAMP_F","#R036749_001_RAMP_V","#R036749_002_RAMP_F","#R036749_002_RAMP_V","#R036750_001_RAMP_F","#R036750_001_RAMP_V","#R036750_002_RAMP_F","#R036750_002_RAMP_V","#R036751_001_RAMP_F","#R036751_001_RAMP_V","#R036751_002_RAMP_F","#R036751_002_RAMP_V","#R036752_001_RAMP_F","#R036752_001_RAMP_V","#R036752_002_RAMP_F","#R036752_002_RAMP_V","#R036753_001_RAMP_F","#R036753_001_RAMP_V","#R036753_002_RAMP_F","#R036753_002_RAMP_V","#R036754_001_RAMP_F","#R036754_001_RAMP_V","#R036755_001_RAMP_F","#R036755_001_RAMP_V","#R036756_001_RAMP_F","#R036756_001_RAMP_V","#R036757_001_RAMP_F","#R036757_001_RAMP_V","#R036758_001_RAMP_F","#R036758_001_RAMP_V","#R036759_001_RAMP_F","#R036759_001_RAMP_V","#R036760_001_RAMP_F","#R036760_001_RAMP_V","#R036761_001_RAMP_F","#R036761_001_RAMP_V","#SSE_PPCCGT_20","CA_SYDS_59A889E5_1","Q>BCCP_BCRG_CLWU","Q>BCCP_CLWU_BCRG","Q>BCCP_CLWU_LCCP","Q>BCCP_LCCP_CLWU","Q>BCCP_RGLC_CLWU","Q>BCLC_BCCP_CLWU","Q>BCLC_CLWU_BCCP","Q>BCNE_BCBS_STNBS","Q>BCST_BCST_CLWU","Q>BCST_BCST_STBS","Q>BSNE_834_BSNE","Q>CLWU_BCCP_BCRG","Q>CLWU_BCRG_BCCP","Q>CLWU_BCST_BCST","Q>CLWU_LCCP_BCCP","Q^CN_FDR-030","Q^CN_FDR-060","Q^CN_FDR-120","Q^CN_FDR-150","Q^CN_FDR-180","Q^CN_FDR-200","Q^CN_GT-060","Q^CN_GT-090","Q^CN_GT-150","Q^CN_GT-180","Q^CS_-080","Q^FNQ_8905_-100","Q_2+1_R2_ALDGASF1","Q_2+1_R2_ALDGASF1_I","Q_2+1_R2_CLARESF1","Q_2+1_R2_CLARESF1_I","Q_2+1_R2_CSPVPS1","Q_2+1_R2_CSPVPS1_I","Q_2+1_R2_DAYDSF1","Q_2+1_R2_DAYDSF1_I","Q_2+1_R2_HAMISF1","Q_2+1_R2_HAMISF1_I","Q_2+1_R2_HAUGHT11","Q_2+1_R2_HAUGHT11_I","Q_2+1_R2_HAYMSF1","Q_2+1_R2_HAYMSF1_I","Q_2+1_R2_KABANWF1","Q_2+1_R2_KABANWF1_I","Q_2+1_R2_KEP","Q_2+1_R2_KEP_I","Q_2+1_R2_KSP1","Q_2+1_R2_KSP1_I","Q_2+1_R2_MEWF1","Q_2+1_R2_MEWF1_I","Q_2+1_R2_RRSF1","Q_2+1_R2_RRSF1_I","Q_2+1_R2_RUGBYR1","Q_2+1_R2_RUGBYR1_I","Q_2+1_R2_SMCSF1","Q_2+1_R2_SMCSF1_I","Q_2+1_R2_WHITSF1","Q_2+1_R2_WHITSF1_I","Q_2+1_R3_ALDGASF1","Q_2+1_R3_ALDGASF1_I","Q_2+1_R3_CLARESF1","Q_2+1_R3_CLARESF1_I","Q_2+1_R3_CSPVPS1","Q_2+1_R3_CSPVPS1_I","Q_2+1_R3_DAYDSF1","Q_2+1_R3_DAYDSF1_I","Q_2+1_R3_HAMISF1","Q_2+1_R3_HAMISF1_I","Q_2+1_R3_HAUGHT11","Q_2+1_R3_HAUGHT11_I","Q_2+1_R3_HAYMSF1","Q_2+1_R3_HAYMSF1_I","Q_2+1_R3_KABANWF1","Q_2+1_R3_KABANWF1_I","Q_2+1_R3_KEP","Q_2+1_R3_KEP_I","Q_2+1_R3_KSP1","Q_2+1_R3_KSP1_I","Q_2+1_R3_MEWF1","Q_2+1_R3_MEWF1_I","Q_2+1_R3_RRSF1","Q_2+1_R3_RRSF1_I","Q_2+1_R3_RUGBYR1","Q_2+1_R3_RUGBYR1_I","Q_2+1_R3_SMCSF1","Q_2+1_R3_SMCSF1_I","Q_2+1_R3_WHITSF1","Q_2+1_R3_WHITSF1_I","Q_2+1_R4_ALDGASF1","Q_2+1_R4_ALDGASF1_I","Q_2+1_R4_CLARESF1","Q_2+1_R4_CLARESF1_I","Q_2+1_R4_CSPVPS1","Q_2+1_R4_CSPVPS1_I","Q_2+1_R4_DAYDSF1","Q_2+1_R4_DAYDSF1_I","Q_2+1_R4_HAMISF1","Q_2+1_R4_HAMISF1_I","Q_2+1_R4_HAUGHT11","Q_2+1_R4_HAUGHT11_I","Q_2+1_R4_HAYMSF1","Q_2+1_R4_HAYMSF1_I","Q_2+1_R4_KABANWF1","Q_2+1_R4_KABANWF1_I","Q_2+1_R4_KEP","Q_2+1_R4_KEP_I","Q_2+1_R4_KSP1","Q_2+1_R4_KSP1_I","Q_2+1_R4_MEWF1","Q_2+1_R4_MEWF1_I","Q_2+1_R4_RRSF1","Q_2+1_R4_RRSF1_I","Q_2+1_R4_RUGBYR1","Q_2+1_R4_RUGBYR1_I","Q_2+1_R4_SMCSF1","Q_2+1_R4_SMCSF1_I","Q_2+1_R4_WHITSF1","Q_2+1_R4_WHITSF1_I","Q_2+3+VC_CLARESF1","Q_2+3+VC_CLARESF1_I","Q_2+3+VC_CSPVPS1","Q_2+3+VC_CSPVPS1_I","Q_2+3+VC_DAYDSF1","Q_2+3+VC_DAYDSF1_I","Q_2+3+VC_HAMISF1","Q_2+3+VC_HAMISF1_I","Q_2+3+VC_HAUGHT11","Q_2+3+VC_HAUGHT11_I","Q_2+3+VC_HAYMSF1","Q_2+3+VC_HAYMSF1_I","Q_2+3+VC_KABANWF1","Q_2+3+VC_KABANWF1_I","Q_2+3+VC_KEP","Q_2+3+VC_KEP_I","Q_2+3+VC_KSP1","Q_2+3+VC_KSP1_I","Q_2+3+VC_MEWF1","Q_2+3+VC_MEWF1_I","Q_2+3+VC_RRSF1","Q_2+3+VC_RRSF1_I","Q_2+3+VC_RUGBYR1","Q_2+3+VC_RUGBYR1_I","Q_2+3+VC_SMCSF1","Q_2+3+VC_SMCSF1_I","Q_2+3+VC_WHITSF1","Q_2+3+VC_WHITSF1_I","Q_2+BCLC_ALDGASF1","Q_2+BCLC_ALDGASF1_I","Q_2+BCLC_BRDDSF01","Q_2+BCLC_BRDDSF01_I","Q_2+BCLC_CLARESF1","Q_2+BCLC_CLARESF1_I","Q_2+BCLC_CSPVPS1","Q_2+BCLC_CSPVPS1_I","Q_2+BCLC_DAYDSF1","Q_2+BCLC_DAYDSF1_I","Q_2+BCLC_HAMISF1","Q_2+BCLC_HAMISF1_I","Q_2+BCLC_HAUGHT11","Q_2+BCLC_HAUGHT11_I","Q_2+BCLC_HAYMSF1","Q_2+BCLC_HAYMSF1_I","Q_2+BCLC_KABANWF1","Q_2+BCLC_KABANWF1_I","Q_2+BCLC_KEP","Q_2+BCLC_KEP_I","Q_2+BCLC_KSP1","Q_2+BCLC_KSP1_I","Q_2+BCLC_MEWF1","Q_2+BCLC_MEWF1_I","Q_2+BCNE_ALDGASF1","Q_2+BCNE_ALDGASF1_I","Q_2+BCNE_CLARESF1","Q_2+BCNE_CLARESF1_I","Q_2+BCNE_CSPVPS1","Q_2+BCNE_CSPVPS1_I","Q_2+BCNE_DAYDSF1","Q_2+BCNE_DAYDSF1_I","Q_2+BCNE_HAMISF1","Q_2+BCNE_HAMISF1_I","Q_2+BCNE_HAUGHT11","Q_2+BCNE_HAUGHT11_I","Q_2+BCNE_HAYMSF1","Q_2+BCNE_HAYMSF1_I","Q_2+BCNE_KABANWF1","Q_2+BCNE_KABANWF1_I","Q_2+BCNE_KEP","Q_2+BCNE_KEP_I","Q_2+BCNE_KSP1","Q_2+BCNE_KSP1_I","Q_2+BCNE_MEWF1","Q_2+BCNE_MEWF1_I","Q_2+BCNE_RRSF1","Q_2+BCNE_RRSF1_I","Q_2+BCNE_RUGBYR1","Q_2+BCNE_RUGBYR1_I","Q_2+BCNE_SMCSF1","Q_2+BCNE_SMCSF1_I","Q_2+BCNE_WHITSF1","Q_2+BCNE_WHITSF1_I","Q_2+RSVC_ALDGASF1","Q_2+RSVC_ALDGASF1_I","Q_2+RSVC_CLARESF1","Q_2+RSVC_CLARESF1_I","Q_2+RSVC_CSPVPS1","Q_2+RSVC_CSPVPS1_I","Q_2+RSVC_DAYDSF1","Q_2+RSVC_DAYDSF1_I","Q_2+RSVC_HAMISF1","Q_2+RSVC_HAMISF1_I","Q_2+RSVC_HAUGHT11","Q_2+RSVC_HAUGHT11_I","Q_2+RSVC_HAYMSF1","Q_2+RSVC_HAYMSF1_I","Q_2+RSVC_KABANWF1","Q_2+RSVC_KABANWF1_I","Q_2+RSVC_KEP","Q_2+RSVC_KEP_I","Q_2+RSVC_KSP1","Q_2+RSVC_KSP1_I","Q_2+RSVC_MEWF1","Q_2+RSVC_MEWF1_I","Q_2+RSVC_RRSF1","Q_2+RSVC_RRSF1_I","Q_2+RSVC_RUGBYR1","Q_2+RSVC_RUGBYR1_I","Q_2+RSVC_SMCSF1","Q_2+RSVC_SMCSF1_I","Q_2+RSVC_WHITSF1","Q_2+RSVC_WHITSF1_I","Q_CN1200","Q_CS_2000","Q_STR_ALDSF_I","Q_STR_ALDSF_ZERO","TVBL_NIL_CONT_473","V>>BELMLCB_BAML_TGML","VTBL_NIL_CONT_453"]},"GENCONSETID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique ID for the Constraint Set","examples":["#DRYCGT1_DE","#DRYCGT2_DE","#R036713_RAMP","#R036714_RAMP","#R036715_RAMP","#R036716_RAMP","#R036717_RAMP","#R036718_RAMP","#R036719_RAMP","#R036720_RAMP","#R036721_RAMP","#R036722_RAMP","#R036723_RAMP","#R036724_RAMP","#R036725_RAMP","#R036726_RAMP","#R036727_RAMP","#R036728_RAMP","#R036729_RAMP","#R036730_RAMP","#R036731_RAMP","#R036732_RAMP","#R036733_RAMP","#R036734_RAMP","#R036735_RAMP","#R036736_RAMP","#R036737_RAMP","#R036738_RAMP","#R036739_RAMP","#R036740_RAMP","#R036741_RAMP","#R036742_RAMP","#R036743_RAMP","#R036744_RAMP","#R036745_RAMP","#R036746_RAMP","#R036747_RAMP","#R036748_RAMP","#R036749_RAMP","#R036750_RAMP","#R036751_RAMP","#R036752_RAMP","#R036753_RAMP","#R036754_RAMP","#R036755_RAMP","#R036756_RAMP","#R036757_RAMP","#R036758_RAMP","#R036759_RAMP","#R036760_RAMP","#R036761_RAMP","#SSE_PPCCGT_20","CA_SYDS_59A889E5","I-TV_CLPS","Q-BCBS_820","Q-BCCP_812","Q-BCNE_821","Q-BCRG_811","Q-BCST","Q-BSNE","Q-BSNE_834","Q-BS_275BUS_CB","Q-CLST","Q-CLWU","Q-CL_275BUS_CB","Q-CPWU_818","Q-H13RS_SVC","Q-HAURS","Q-NESTM","Q-NE_275BUS_CB","Q-RS_275BUS_CB","Q-SMHAU","Q-SMRS","Q-SMRS_N-2","Q-SM_275BUS_CB","Q-ST_275BUS_CB","Q-X_2FNQ+3NQ+VC","V-X_BAELML_BAML_B1CB"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the record for the given effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"GENCONEFFDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Since market start in 1998 these fields have not been used and any data that has been populated in the fields should be ignored","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Since market start in 1998 these fields have not been used and any data that has been populated in the fields should be ignored","examples":["1"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENCONSET%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":63135,"decompressed_size_all_time":45305180},"visibility":"Public","trigger":"When updated by AEMO"},"GENCONSETINVOKE":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENCONSETINVOKE","REPORT_SUB_TYPE":"NULL","VERSION":2},{"REPORT_NAME":"GENERIC_CONSTRAINT","REPORT_SUB_TYPE":"GENCONSETINVOKE","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#27"],"comment":"GENCONSETINVOKE provides details of invoked and revoked generic constraints. GENCONSETINVOKE is the key table for determining what constraints are active in dispatch, predispatch and PASA.\nGENCONSETINVOKE also indicates whether constraints are for interconnector limits, ancillary services, etc.","description":"GENCONSETINVOKE is public data. All participants have access to this\ndata.\n\nSource\n\nGENCONSETINVOKE updates each time a generic constraint is invoked or\nrevoke time is altered. Once past the time, these times cannot be\naltered.\n\nNote\n\nThe Replica software does not handle the deletion of GENCONSETINVOKE\nrecords. To workaround this problem, the field STARTAUTHORISEDBY\nindicates whether a constraint set invocation is applicable. A non-null\nvalue for the STARTAUTHORISEDBY field indicates that the constraint\ninvocation is active. Essentially inactive invocations have a null value\nfor the STARTAUTHORISEDBY field. To remove inactive invocations from\nqueries on the GENCONSETINVOKE table, add the following text to the\nwhere clause \"and STARTAUTHORISEDBY is not null\".","primary_keys":["INVOCATION_ID"],"indexes":[["LASTCHANGED"]],"columns":{"INVOCATION_ID":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":true,"comment":"Abstract unique identifier for the record. Allows Invocations to be modified without affecting PK values","examples":["221609","236959"],"is_integer":true,"num_int_bits":32},"ASCONSTRAINTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Constraint type (e.g. ancillary services). This also flags where a constraint is an interconnector or intra-region network limit.","examples":["INFLEXIBLE","NETWORK","SSE"]},"ENDAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"user authorising revoke."},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Market date end","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ENDINTERVALDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The settlement date and time corresponding to the last interval to which the constraint set is to be applied.","examples":["2026/09/01 07:20:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Dispatch interval number end","examples":["2","288"],"is_integer":true,"num_int_bits":16},"GENCONSETID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique generic constraint set identifier","examples":["#DRYCGT1_DE","#DRYCGT2_DE","#QPS5_DE","#R036705_RAMP","#R036713_RAMP","#R036714_RAMP","#R036715_RAMP","#R036716_RAMP","#R036717_RAMP","#R036718_RAMP","#R036719_RAMP","#R036720_RAMP","#R036721_RAMP","#R036722_RAMP","#R036723_RAMP","#R036724_RAMP","#R036725_RAMP","#R036726_RAMP","#R036727_RAMP","#R036728_RAMP","#R036729_RAMP","#R036730_RAMP","#R036731_RAMP","#R036732_RAMP","#R036733_RAMP","#R036734_RAMP","#R036735_RAMP","#R036736_RAMP","#R036737_RAMP","#R036738_RAMP","#R036739_RAMP","#R036740_RAMP","#R036741_RAMP","#R036742_RAMP","#R036743_RAMP","#R036744_RAMP","#R036745_RAMP","#R036746_RAMP","#R036747_RAMP","#R036748_RAMP","#R036749_RAMP","#R036750_RAMP","#R036751_RAMP","#R036752_RAMP","#R036753_RAMP","#R036754_RAMP","#R036755_RAMP","#R036756_RAMP","#R036757_RAMP","#R036758_RAMP","#R036759_RAMP","#R036760_RAMP","#R036761_RAMP","#R036762_RAMP","#R036763_RAMP","#R036764_RAMP","#R036765_RAMP","#R036766_RAMP","#R036767_RAMP","#R036768_RAMP","#R036769_RAMP","#R036770_RAMP","#R036771_RAMP","#R036772_RAMP","#R036773_RAMP","#R036774_RAMP","#R036775_RAMP","#R036776_RAMP","#R036777_RAMP","#R036778_RAMP","#R036779_RAMP","#R036780_RAMP","#R036781_RAMP","#R036782_RAMP","#R036783_RAMP","#R036784_RAMP","#R036785_RAMP","#R036786_RAMP","#R036787_RAMP","#R036788_RAMP","#R036789_RAMP","#R036790_RAMP","#R036791_RAMP","#R036792_RAMP","#R036793_RAMP","#R036794_RAMP","#R036795_RAMP","#R036796_RAMP","#R036797_RAMP","#R036798_RAMP","#R036799_RAMP","#R036800_RAMP","#R036801_RAMP","#R036802_RAMP","#R036803_RAMP","#R036804_RAMP","#R036805_RAMP","#R036806_RAMP","#R036807_RAMP","#R036808_RAMP","#R036809_RAMP","#R036810_RAMP","#R036811_RAMP","#R036812_RAMP","#R036813_RAMP","#R036814_RAMP","#R036815_RAMP","#R036816_RAMP","#R036817_RAMP","#R036818_RAMP","#R036819_RAMP","#R036820_RAMP","#R036821_RAMP","#R036822_RAMP","#R036823_RAMP","#R036824_RAMP","#R036825_RAMP","#R036826_RAMP","#R036827_RAMP","#R036828_RAMP","#R036829_RAMP","#R036830_RAMP","#R036831_RAMP","#R036832_RAMP","#R036833_RAMP","#R036834_RAMP","#R036835_RAMP","#R036836_RAMP","#R036837_RAMP","#R036838_RAMP","#R036839_RAMP","#R036840_RAMP","#R036841_RAMP","#R036842_RAMP","#R036843_RAMP","#R036844_RAMP","#R036845_RAMP","#R036846_RAMP","#R036847_RAMP","#R036848_RAMP","#R036849_RAMP","#R036850_RAMP","#R036851_RAMP","#R036852_RAMP","#R036853_RAMP","#R036854_RAMP","#R036855_RAMP","#R036856_RAMP","#R036857_RAMP","#R036858_RAMP","#R036859_RAMP","#R036860_RAMP","#R036861_RAMP","#R036862_RAMP","#R036863_RAMP","#R036864_RAMP","#R036865_RAMP","#R036866_RAMP","#R036867_RAMP","#R036868_RAMP","#R036869_RAMP","#R036870_RAMP","#R036871_RAMP","#R036872_RAMP","#R036873_RAMP","#R036874_RAMP","#R036875_RAMP","#R036876_RAMP","#R036877_RAMP","#R036878_RAMP","#R036879_RAMP","#R036880_RAMP","#R036881_RAMP","#R036883_RAMP","#R036884_RAMP","#R036885_RAMP","#R036886_RAMP","#R036887_RAMP","#R036888_RAMP","#R036889_RAMP","#R036890_RAMP","#R036891_RAMP","#R036892_RAMP","#R036893_RAMP","#R036894_RAMP","#R036895_RAMP","#R036896_RAMP","#R036897_RAMP","#R036898_RAMP","#R036899_RAMP","#R036900_RAMP","#R036901_RAMP","#R036902_RAMP","#R036903_RAMP","#R036904_RAMP","#R036905_RAMP","#R036906_RAMP","#R036907_RAMP","#R036908_RAMP","#R036909_RAMP","#R036910_RAMP","#R036911_RAMP","#R036912_RAMP","#R036913_RAMP","#R036914_RAMP","#R036915_RAMP","#R036916_RAMP","#R036917_RAMP","#R036918_RAMP","#R036919_RAMP","#R036920_RAMP","#R036921_RAMP","#R036922_RAMP","#R036923_RAMP","#R036924_RAMP","#R036925_RAMP","#R036926_RAMP","#R036927_RAMP","#R036928_RAMP","#R036929_RAMP","#R036930_RAMP","#R036931_RAMP","#R036932_RAMP","#R036933_RAMP","#R036934_RAMP","#R036935_RAMP","#R036936_RAMP","#R036937_RAMP","#R036938_RAMP","#R036939_RAMP","#R036940_RAMP","#R036941_RAMP","#R036942_RAMP","#R036943_RAMP","#R036944_RAMP","#R036945_RAMP","#R036946_RAMP","#R036947_RAMP","#R036948_RAMP","#R036949_RAMP","#R036950_RAMP","#R036951_RAMP","#R036952_RAMP","#R036953_RAMP","#R036954_RAMP","#R036955_RAMP","#R036956_RAMP","#R036957_RAMP","#R036958_RAMP","#R036959_RAMP","#R036960_RAMP","#R036961_RAMP","#R036962_RAMP","#R036963_RAMP","#R036964_RAMP","#R036965_RAMP","#R036966_RAMP","#R036967_RAMP","#R036968_RAMP","#R036969_RAMP","#R036970_RAMP","#R036971_RAMP","#R036972_RAMP","#R036973_RAMP","#R036974_RAMP","#R036975_RAMP","#R036976_RAMP","#R036977_RAMP","#R036978_RAMP","#R036979_RAMP","#R036980_RAMP","#R036981_RAMP","#R036982_RAMP","#R036983_RAMP","#R036984_RAMP","#R036985_RAMP","#R036986_RAMP","#R036987_RAMP","#R036988_RAMP","#R036989_RAMP","#R036990_RAMP","#R036991_RAMP","#R036992_RAMP","#R036993_RAMP","#R036994_RAMP","#R036995_RAMP","#R036996_RAMP","#R036997_RAMP","#R036998_RAMP","#R036999_RAMP","#R037000_RAMP","#R037001_RAMP","#R037004_RAMP","#R037007_RAMP","#R037008_RAMP","#R037009_RAMP","#R037010_RAMP","#R037011_RAMP","#SSE_PPCCGT_20","#SSE_PPCCGT_21","#SSE_PPCCGT_22","#SSE_PPCCGT_23","#SSE_PPCCGT_24","#SSE_PPCCGT_25","#SSE_PPCCGT_26","#SSE_PPCCGT_27","#SSE_PPCCGT_28","#SSE_PPCCGT_29","#SSE_PPCCGT_30","#SSE_PPCCGT_31","#SSE_PPCCGT_32","#SSE_PPCCGT_33","#SSE_PPCCGT_34","#TORRB4_DE","#TORRB4_E","#VIC1_E_20260915","#VIC1_E_20260916","C-N_ERB02_006","C-N_WILLBES1_075","C-N_WILLBES1_150","C-N_WILLBES1_200","C-N_WILLBES1_250","C-S_CGBESS01_060","C-S_SMFBESS1_040","C-S_SMFBESS2_040","C-S_SMFBESS2_080","C-V_GPWFWST_462","C-V_GPWFWST_557","C-V_MRNBESS1_168","C-V_MRNBESS1_240","C-V_PLBESS1_007","C-V_PLBESS1_061","CA_BRIS_59B1EA1C","CA_SYDS_59A889E5","F-I_ML_APD","F-I_ML_APD_LOAD","F-Q_GSTONE2_ZERO","F-Q_GSTONE4_ZERO","F-Q_OAKEY1_ZERO","F-Q_OAKEY2_ZERO","F-Q_TARONG#2_ZERO","F-Q_TARONG#3_ZERO","F-Q_TARONG#4_ZERO","F-T-CSGO","F-T-FARE_N-2","I-BDBU_ONE","I-BURC_X1","I-BURC_X9","I-CTRL_ISSUE_BL","I-HYSE","I-LTMS","I-ML_SV_EQ_020","I-ML_VS_EQ_020","I-ML_ZERO","I-MURRAYLINK","I-SVML_050","I-VN_0600","I-VSML_050","I-X_64+67/68","I-X_BABU_BURC","N-966+KK","N-ALJN_99B","N-ARCH_96C","N-ARKS_965","N-ARTW_86","N-BABU","N-BADP","N-BAMB_132_OPEN","N-BANCO_973","N-BANCO_999","N-BANGOWF1_ZERO","N-BANYS_9GL","N-BECRD_94M","N-BERYLSF1_ZERO","N-BHBESS_ZERO_INV","N-BROKENH1_ZERO","N-BU_CB7012","N-BWLD_ONE","N-BWMP_5A3","N-BYMN_ONE_15M","N-BYTX","N-CHKS_ONE","N-CHRL_9W3","N-CH_TX","N-CLDP_99T_A","N-CNCW_6_15M","N-CNYS_9","N-COLWF_TX","N-CRGR_3H","N-CRWF1_ZERO","N-DBWL_ONE","N-DM_CB","N-DM_SVC","N-DPTX1-2","N-DPYC-99D-C","N-DTKV_18_WG_CLOSE","N-DTKV_18_WG_OPEN","N-DTMN_8_15M","N-DTSS_11","N-DTTL_984","N-ERA2_BESS_BDU_ZERO","N-ERNC_90","N-ERVY_25","N-FINLYSF1_ZERO_INV","N-GFYC-99J-C","N-GNNDHSF1_ZERO_INV","N-GOONSF1_ZERO_INV","N-GRYS_3J_15M","N-IVWR-9U4","N-KKLS_967","N-KVCW_3W_WG_CLOSE","N-LDNC_81","N-LDTM_82","N-LPSW30+RGSW38","N-LSDU_9U6","N-LSLS_9U8","N-LS_VC1","N-LTUT_64_15M","N-LTWG_X5","N-MBTE_1","N-MMWB_ONE","N-MOON_94T","N-MORBOR","N-MP02_ZERO","N-MPTX","N-MPTX_94Y","N-MPWO_5A5","N-MPWW_ONE","N-MUTW_88","N-NAGU","N-NATX","N-NESBESS_BDU_ZERO","N-PKWL_94K_2","N-PK_TX","N-RGSW_38","N-SNVP_22","N-SOWL_79","N-SOWS_7M","N-STWF1_ZERO","N-SWVY_29","N-TAGU_969","N-TAPM_964","N-TWNR_968","N-TWUL_85","N-TW_SVC","N-UR_ZERO","N-UTRV_6X","N-WELLSF1_ZERO","N-WGN_132BUS_1","N-WGWGA_99W","N-WLMO_945","N-WLMP_72","N-WLWLSF1_ZERO","N-WNWG_9R5","N-WOODLWN1_ZERO","N-WOWS_75","N-WSTWYSF_ZERO","N-WYASF1_ZERO","N-X_966+KK+CH_CB892A","N-X_BADP_DTKV","N-X_BU-SCON2+3","N-X_BU_SC_4_5","N-X_TW_330_BUS3-5","N-YCNA_9HR_C","N-YCNA_9HT_C","N-YSTX","NC-N_BW02","NC-N_NESBESS1","NC-N_WTAHB1","NC-Q_MPP_1","NC-S_ADPBA1","NC-S_BNGSF2","NC-S_TB2B1","NC-S_TORRB4","NC-T_CETHANA","NC-V_CROWLWF1","NC-V_GPWFWST1","NC-V_MRNBESS1","NC-V_YWPS4","Q-810_PARALLEL_CLOSE","Q-B2PSBRA_8840","Q-BKRL_8818","Q-BK_VC","Q-BOUL_BESS_BDU_ZERO","Q-BSNE","Q-CLBTX","Q-CLST","Q-CL_275BUS_CB","Q-CN1000","Q-CN_FDR-150","Q-CN_GT-240","Q-CPWO_814","Q-CPWO_BI_INTACT","Q-CYPW","Q-GLD2_0","Q-GLD4_0","Q-GMG_275BUS_CB","Q-H11NE_SVC","Q-H13RS_SVC","Q-H35STM_SVC","Q-HATR","Q-KMBG_7184","Q-LCCP_8859","Q-MEBK_802","Q-MRTA_732","Q-MSPTS_7243","Q-NESTM","Q-NIL_BI_INTACT","Q-OKTA_7246","Q-OKTA_7247","Q-PWSP_808","Q-RLSP_809","Q-SMSPL","Q-SM_275BUS_CB","Q-SPL_TX_1","Q-SPL_TX_2","Q-STR_ALDSF_ZERO","Q-STR_BRDDSF01_005","Q-TRME","Q-TR_TG_842","Q-TR_TG_843","Q-TR_TG_844","Q-WDHA_8867","Q-WOCY","Q-WRTX","Q-WR_VC","Q-X_2FNQ+3NQ+VC","Q-X_BSNE+CLST","Q-X_BSNE_NESM","Q-X_HATR_TWO","Q-X_METR+BKME","Q-X_NE_STM_SVC","Q-X_NQ_275_FDR_THREE","Q-X_TRME_TRME","S-ACMA","S-ACPA","S-AC_CB6066","S-BC_CP","S-BLWI","S-BRDV","S-CGMS","S-CGTI","S-DC_CBG3","S-DVEM","S-DVTX","S-HUWT","S-KHKN","S-KHKN_BC-2CP","S-MAMAP2","S-MAMAP2_BC-2CP","S-MGPA","S-MGTI","S-MH_CAP","S-MSTU","S-MWP3RB","S-MWPS2-MWPS3","S-MWPS3-PV_0","S-NWCB6024+23","S-NWRB2","S-PA_CB6509","S-PA_VC1","S-PA_VC1_BC-2CP","S-SECB6611_10","S-SECB6611_10_BC-2CP","S-SE_132KV_BUS","S-SE_VC1","S-SE_VC1_BC-2CP","S-TB132_E_BUS","S-TB275_E_BUS","S-TB2_TX","S-TBSE","S-TB_CB6123","S-TB_CB6125","S-TB_CB6536","S-TIBAT1_0","S-TINO3","S-X_BWMP+MPPA","T-BUSH_220_WCP_OPEN","T-CSGO_N-2","T-CSLI","T-GH_RC12_250","T-GTSH","T-LE_ZERO","T-LTSH","T-NIL_WCP_CLOSE","T-NIL_WCP_OPEN","T-PMPO_220","T-PMPO_THREE_220","T-PMPO_TWO_110","T-PMPO_TWO_220","T-PMWA","T-TA_ZERO","T-TUWA12_110_N-2","T-TU_0","V-APHY_1","V-BALL_BESS_BDU_ZERO","V-BA_EL_ML","V-CPRC","V-DBUSS_L","V-DBUSS_T","V-DDGN","V-DDMS","V-DDSM","V-DDTX3_DBUSS_T","V-DPMB","V-DUNDWF1_ZERO","V-DUNDWF2_ZERO","V-DUNDWF3_ZERO","V-EL_TX_R1","V-GPWFWST1_ZERO","V-GTML","V-HM_VIC_ZERO","V-HWRO3","V-HWSM","V-HWYP1","V-LAVNTH1_ZERO","V-LYPSA3_ZERO","V-LYPSA4_ZERO","V-MBMK","V-MLSY_NOEMTT_R","V-MLTX_A1","V-MLTX_A2","V-MSSGG_TX","V-MTGELIBRAND_66","V-RANGEB_BDU_ZERO","V-RCTS220CAPAUTO","V-RCTS220CAPSAUTO","V-RCWT","V-ROSM","V-ROYP78_R","V-ROYP78_R_N-2","V-SALTCREEK_ZERO","V-SMSC","V-SMSY","V-SMTT2","V-SMTX_F_R","V-SY_CB","V-TRTS_BUS_CB_500","V-TSTT_R","V-VBB_BESS_BDU_ZERO","V-WOORB1_BDU_ZERO","V-X_BAELML_BAML_B1CB","V-X_HWRO_12_R","V-X_HWSM_HWRO3","V-YP_BUS1"]},"INTERVENTION":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"0 is not intervention, 1 is intervention and causes dispatch to solve twice.","examples":["Y","N"],"warnings":["Unlike most tables with an INTERVENTION column, and contrary to the official documentation, INTERVENTION takes values `N` and `Y` not 0 and 1.: 1 N: 0\n","Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of GENCONSETINVOKE."],"parse_csv_as_string":true,"value_map":{"Y":1,"N":0},"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 03:10:58"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising invoke, indicating a constraint set invocation is applicable (i.e. non-null). A null value indicates inactive invocation.","examples":["AAShfaq","AAshfaq","ABRAHAMY","ANL","BASHFORD","BATCH","BCHHETRI","BOGDANV","BSANGHAVI","Batch","COMPMON","Cpitt","DALJURE","DGILMOUR","DHARVINL","DHOOLE","DPAT","FRANKB","GWEGENER","INDJI-MTAE","INDJI-MTAG","INDJI-MTAN","INDJI-MVP3","JAGUEST","JDUQUE","JHOO","JRUFF","JWRIGHT","KHOUNSELL","KINW","KNGUYEN2","KPERERA","MATING","MBHASKAR","MJAMES2","MSHAKERI","MYANG","MingchenG","PARULS","RAMITHAW","RSHARMA2","SHENGG","SNIEK","SPILLAY2","SRAJAPAKSE2","VBAJPAI","WSCHIE","cpitt","fboros","knguyen2","ryang","vbajpai","yingxu"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date of start","examples":["2026/02/08 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STARTINTERVALDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The settlement date and time corresponding to the first interval to which the constraint set is to be applied.","examples":["2026/02/08 16:40:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The first dispatch interval of the invocation being the dispatch interval number starting from1 at 04:05.","examples":["1","282"],"is_integer":true,"num_int_bits":16},"SYSTEMNORMAL":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the constraint set is a system normal (1) or an outage set (0)","examples":["0","1"],"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENCONSETINVOKE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":34862,"decompressed_size_all_time":32132280},"visibility":"Public","trigger":"When a generic constraint is invoked or the revoke time is altered"},"GENCONSETTRK":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENCONSETTRK","REPORT_SUB_TYPE":"NULL","VERSION":1},{"REPORT_NAME":"GENCONSETTRK","REPORT_SUB_TYPE":"NULL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#36"],"comment":"GENCONSETTRK assists in determining the correct version of a generic constraint set that has been invoked in GENCONSETINVOKE.","description":"GENCONSETTRK data is public to all participants.\n\nSource\n\nAd hoc updates occur to GENCONSETTRK.","primary_keys":["EFFECTIVEDATE","GENCONSETID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date this record becomes effective","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONSETID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique ID for the Constraint Set","examples":["#BARKIPS1_DE","#DRYCGT1_DE","#DRYCGT2_DE","#MCINTYR1_E","#NSW1-QLD1_RAMP_I","#QPS5_DE","#R036713_RAMP","#R036714_RAMP","#R036715_RAMP","#R036716_RAMP","#R036717_RAMP","#R036718_RAMP","#R036719_RAMP","#R036720_RAMP","#R036721_RAMP","#R036722_RAMP","#R036723_RAMP","#R036724_RAMP","#R036725_RAMP","#R036726_RAMP","#R036727_RAMP","#R036728_RAMP","#R036729_RAMP","#R036730_RAMP","#R036731_RAMP","#R036732_RAMP","#R036733_RAMP","#R036734_RAMP","#R036735_RAMP","#R036736_RAMP","#R036737_RAMP","#R036738_RAMP","#R036739_RAMP","#R036740_RAMP","#R036741_RAMP","#R036742_RAMP","#R036743_RAMP","#R036744_RAMP","#R036745_RAMP","#R036746_RAMP","#R036747_RAMP","#R036748_RAMP","#R036749_RAMP","#R036750_RAMP","#R036751_RAMP","#R036752_RAMP","#R036753_RAMP","#R036754_RAMP","#R036755_RAMP","#R036756_RAMP","#R036757_RAMP","#R036758_RAMP","#R036759_RAMP","#R036760_RAMP","#R036761_RAMP","#R036762_RAMP","#R036763_RAMP","#R036764_RAMP","#R036765_RAMP","#R036766_RAMP","#R036767_RAMP","#R036768_RAMP","#R036769_RAMP","#R036770_RAMP","#R036771_RAMP","#R036772_RAMP","#R036773_RAMP","#R036774_RAMP","#R036775_RAMP","#R036776_RAMP","#R036777_RAMP","#R036778_RAMP","#R036779_RAMP","#R036780_RAMP","#R036781_RAMP","#R036782_RAMP","#R036783_RAMP","#R036784_RAMP","#R036785_RAMP","#R036786_RAMP","#R036787_RAMP","#R036788_RAMP","#R036789_RAMP","#R036790_RAMP","#R036791_RAMP","#R036792_RAMP","#R036793_RAMP","#R036794_RAMP","#R036795_RAMP","#R036796_RAMP","#R036797_RAMP","#R036798_RAMP","#R036799_RAMP","#R036800_RAMP","#R036801_RAMP","#R036802_RAMP","#R036803_RAMP","#R036804_RAMP","#R036805_RAMP","#R036806_RAMP","#R036807_RAMP","#R036808_RAMP","#R036809_RAMP","#R036810_RAMP","#R036811_RAMP","#R036812_RAMP","#R036813_RAMP","#R036814_RAMP","#R036815_RAMP","#R036816_RAMP","#R036817_RAMP","#R036818_RAMP","#R036819_RAMP","#R036820_RAMP","#R036821_RAMP","#R036822_RAMP","#R036823_RAMP","#R036824_RAMP","#R036825_RAMP","#R036826_RAMP","#R036827_RAMP","#R036828_RAMP","#R036829_RAMP","#R036830_RAMP","#R036831_RAMP","#R036832_RAMP","#R036833_RAMP","#R036834_RAMP","#R036835_RAMP","#R036836_RAMP","#R036837_RAMP","#R036838_RAMP","#R036839_RAMP","#R036840_RAMP","#R036841_RAMP","#R036842_RAMP","#R036843_RAMP","#R036844_RAMP","#R036845_RAMP","#R036846_RAMP","#R036847_RAMP","#R036848_RAMP","#R036849_RAMP","#R036850_RAMP","#R036851_RAMP","#R036852_RAMP","#R036853_RAMP","#R036854_RAMP","#R036855_RAMP","#R036856_RAMP","#R036857_RAMP","#R036858_RAMP","#R036859_RAMP","#R036860_RAMP","#R036861_RAMP","#R036862_RAMP","#R036863_RAMP","#R036864_RAMP","#R036865_RAMP","#R036866_RAMP","#R036867_RAMP","#R036868_RAMP","#R036869_RAMP","#R036870_RAMP","#R036871_RAMP","#R036872_RAMP","#R036873_RAMP","#R036874_RAMP","#R036875_RAMP","#R036876_RAMP","#R036877_RAMP","#R036878_RAMP","#R036879_RAMP","#R036880_RAMP","#R036881_RAMP","#R036883_RAMP","#R036884_RAMP","#R036885_RAMP","#R036886_RAMP","#R036887_RAMP","#R036888_RAMP","#R036889_RAMP","#R036890_RAMP","#R036891_RAMP","#R036892_RAMP","#R036893_RAMP","#R036894_RAMP","#R036895_RAMP","#R036896_RAMP","#R036897_RAMP","#R036898_RAMP","#R036899_RAMP","#R036900_RAMP","#R036901_RAMP","#R036902_RAMP","#R036903_RAMP","#R036904_RAMP","#R036905_RAMP","#R036906_RAMP","#R036907_RAMP","#R036908_RAMP","#R036909_RAMP","#R036910_RAMP","#R036911_RAMP","#R036912_RAMP","#R036913_RAMP","#R036914_RAMP","#R036915_RAMP","#R036916_RAMP","#R036917_RAMP","#R036918_RAMP","#R036919_RAMP","#R036920_RAMP","#R036921_RAMP","#R036922_RAMP","#R036923_RAMP","#R036924_RAMP","#R036925_RAMP","#R036926_RAMP","#R036927_RAMP","#R036928_RAMP","#R036929_RAMP","#R036930_RAMP","#R036931_RAMP","#R036932_RAMP","#R036933_RAMP","#R036934_RAMP","#R036935_RAMP","#R036936_RAMP","#R036937_RAMP","#R036938_RAMP","#R036939_RAMP","#R036940_RAMP","#R036941_RAMP","#R036942_RAMP","#R036943_RAMP","#R036944_RAMP","#R036945_RAMP","#R036946_RAMP","#R036947_RAMP","#R036948_RAMP","#R036949_RAMP","#R036950_RAMP","#R036951_RAMP","#R036952_RAMP","#R036953_RAMP","#R036954_RAMP","#R036955_RAMP","#R036956_RAMP","#R036957_RAMP","#R036958_RAMP","#R036959_RAMP","#R036960_RAMP","#R036961_RAMP","#R036962_RAMP","#R036963_RAMP","#R036964_RAMP","#R036965_RAMP","#R036966_RAMP","#R036967_RAMP","#R036968_RAMP","#R036969_RAMP","#R036970_RAMP","#R036971_RAMP","#R036972_RAMP","#R036973_RAMP","#R036974_RAMP","#R036975_RAMP","#R036976_RAMP","#R036977_RAMP","#R036978_RAMP","#R036979_RAMP","#R036980_RAMP","#R036981_RAMP","#R036982_RAMP","#R036983_RAMP","#R036984_RAMP","#R036985_RAMP","#R036986_RAMP","#R036987_RAMP","#R036988_RAMP","#R036989_RAMP","#R036990_RAMP","#R036991_RAMP","#R036992_RAMP","#R036993_RAMP","#R036994_RAMP","#R036995_RAMP","#R036996_RAMP","#R036997_RAMP","#R036998_RAMP","#R036999_RAMP","#R037000_RAMP","#R037001_RAMP","#R037002_RAMP","#R037003_RAMP","#R037004_RAMP","#R037005_RAMP","#R037006_RAMP","#R037007_RAMP","#R037008_RAMP","#R037009_RAMP","#R037010_RAMP","#R037011_RAMP","#R037012_RAMP","#R037013_RAMP","#R037014_RAMP","#R037015_RAMP","#R037017_RAMP","#R037018_RAMP","#R037019_RAMP","#R037020_RAMP","#R037021_RAMP","#R037022_RAMP","#R037023_RAMP","#R037024_RAMP","#R037025_RAMP","#R037026_RAMP","#R037027_RAMP","#R037028_RAMP","#R037029_RAMP","#R037030_RAMP","#R037031_RAMP","#R037032_RAMP","#R037033_RAMP","#R037034_RAMP","#R037035_RAMP","#R037036_RAMP","#R037037_RAMP","#R037038_RAMP","#R037039_RAMP","#R037040_RAMP","#R037041_RAMP","#R037042_RAMP","#R037043_RAMP","#R037044_RAMP","#R037045_RAMP","#R037046_RAMP","#R037047_RAMP","#R037048_RAMP","#R037049_RAMP","#R037050_RAMP","#R037051_RAMP","#R037052_RAMP","#R037053_RAMP","#R037054_RAMP","#R037055_RAMP","#R037056_RAMP","#R037057_RAMP","#R037058_RAMP","#R037059_RAMP","#R037060_RAMP","#R037061_RAMP","#R037062_RAMP","#R037063_RAMP","#R037064_RAMP","#R037065_RAMP","#R037066_RAMP","#R037067_RAMP","#R037068_RAMP","#R037069_RAMP","#R037070_RAMP","#R037071_RAMP","#R037072_RAMP","#R037073_RAMP","#R037074_RAMP","#R037075_RAMP","#R037076_RAMP","#R037077_RAMP","#R037078_RAMP","#R037079_RAMP","#R037080_RAMP","#R037081_RAMP","#R037082_RAMP","#R037083_RAMP","#R037084_RAMP","#R037085_RAMP","#R037086_RAMP","#R037087_RAMP","#R037088_RAMP","#R037089_RAMP","#R037090_RAMP","#R037091_RAMP","#SSE_BARKIPS1_40","#SSE_PPCCGT_20","#SSE_PPCCGT_21","#SSE_PPCCGT_22","#SSE_PPCCGT_23","#SSE_PPCCGT_24","#SSE_PPCCGT_25","#SSE_PPCCGT_26","#SSE_PPCCGT_27","#SSE_PPCCGT_28","#SSE_PPCCGT_29","#SSE_PPCCGT_30","#SSE_PPCCGT_31","#SSE_PPCCGT_32","#SSE_PPCCGT_33","#SSE_PPCCGT_34","#SSE_PPCCGT_35","#SSE_PPCCGT_36","#SSE_PPCCGT_37","#SSE_PPCCGT_38","#SSE_PPCCGT_39","#TORRB4_DE","#TORRB4_E","#VIC1_E_20260915","#VIC1_E_20260916","A-N_BHB1_ZERO_E","A-N_BHB1_ZERO_G_E","A-N_CABESA1_ZERO_E","A-N_CABESA1_ZERO_G_E","A-N_CABESA2_ZERO_E","A-N_CABESA2_ZERO_G_E","A-N_ERB01_ZERO_E","A-N_ERB01_ZERO_G_E","A-N_ERB02_ZERO_E","A-N_ERB02_ZERO_G_E","A-N_LDBESS1_ZERO_E","A-N_LDBESS1_ZERO_G_E","A-N_LIMBES1_ZERO_E","A-N_LIMBES1_ZERO_G_E","A-N_MUGALB1_ZERO_E","A-N_MUGALB1_ZERO_G_E","A-N_MUGALB2_ZERO_E","A-N_MUGALB2_ZERO_G_E","A-N_NESBES1_ZERO_E","A-N_NESBES1_ZERO_G_E","A-N_NESBES2_ZERO_E","A-N_NESBES2_ZERO_G_E","A-N_ORABES1_ZERO_E","A-N_ORABES1_ZERO_G_E","A-N_QPSFB2_ZERO_E","A-N_QPSFB2_ZERO_G_E","A-N_WILBES1_ZERO_E","A-N_WILBES1_ZERO_G_E","A-Q_BLUEGB1_ZERO_E","A-Q_BLUEGB1_ZERO_G_E","A-Q_BRDBES1_ZERO_E","A-Q_BRDBES1_ZERO_G_E","A-Q_SNB02_ZERO_E","A-Q_SNB02_ZERO_G_E","A-Q_STABES1_ZERO_E","A-Q_STABES1_ZERO_G_E","A-Q_WOOLES1_ZERO_E","A-Q_WOOLES1_ZERO_G_E","A-S_BUNGAM1_ZERO_E","A-S_BUNGAM1_ZERO_G_E","A-S_CGBESS1_ZERO_E","A-S_CGBESS1_ZERO_G_E","A-S_LGAPBS1_ZERO_E","A-S_LGAPBS1_ZERO_G_E","A-S_MANUMB1_ZERO_E","A-S_MANUMB1_ZERO_G_E","A-S_SMFBES1_ZERO_E","A-S_SMFBES1_ZERO_G_E","A-S_SMFBES2_ZERO_E","A-S_SMFBES2_ZERO_G_E","A-S_TB3B1_ZERO_E","A-S_TB3B1_ZERO_G_E","A-S_TEMPB1_ZERO_E","A-S_TEMPB1_ZERO_G_E","A-V_HREBES1_ZERO_E","A-V_HREBES1_ZERO_G_E","A-V_MLB01_ZERO_E","A-V_MLB01_ZERO_G_E","A-V_MREHA1_ZERO_E","A-V_MREHA1_ZERO_G_E","A-V_MREHA2_ZERO_E","A-V_MREHA2_ZERO_G_E","A-V_MREHA3_ZERO_E","A-V_MREHA3_ZERO_G_E","A-V_MRNBES1_ZERO_E","A-V_MRNBES1_ZERO_G_E","A-V_PLBESS1_ZERO_E","A-V_PLBESS1_ZERO_G_E","A-V_TRGBES1_ZERO_E","A-V_TRGBES1_ZERO_G_E","CA_AUTO","CA_BRIS_59B1E7AD","CA_BRIS_59B1E9F4","CA_BRIS_59B1EA1C","CA_BRIS_59CD80D1","CA_BRIS_59CEBC99","CA_BRIS_59CEC97F","CA_BRIS_59CEE304","CA_SYDS_59A889E5","CA_SYDS_59B363DF","CA_SYDS_59C65DD6","CA_SYDS_59C65E31","I*DATASNAP","I-JNWO_63","I-JNWO_X5","I-NS_050","I-NS_100","I-NS_150","I-NS_200","I-NS_250","I-NS_300","I-NS_350","I-NS_400","I-NS_450","I-NS_500","I-NS_550","I-NS_600","I-NS_650","I-NS_700","I-NS_750","I-NS_800","I-PEC_ZERO","I-SN_050","I-SN_100","I-SN_150","I-SN_200","I-SN_250","I-SN_300","I-SN_350","I-SN_400","I-SN_450","I-SN_500","I-SN_550","I-SN_600","I-SN_650","I-SN_700","I-SN_750","I-SN_800","I-SVS_000","I-SVS_020","I-SVS_040","I-SVS_060","I-SVS_080","I-SVS_100","I-SVS_120","I-SVS_140","I-SVS_160","I-SVS_180","I-SVS_200","I-SVS_220","I-SVS_240","I-SVS_260","I-SVS_270","I-SVS_280","I-SVS_300","I-SVS_340","I-SVS_350","I-SVS_400","I-SVS_420","I-SVS_450","I-SVS_470","I-SVS_500","I-SVS_520","I-SVS_540","I-SVS_550","I-SVS_560","I-SVS_580","I-SVS_600","I-SVS_620","I-SVS_640","I-SVS_650","I-SVS_660","I-SVS_680","I-SVS_700","I-SVS_720","I-SVS_740","I-SVS_750","I-SVS_760","I-SVS_780","I-SVS_800","I-SVS_820","I-SVS_840","I-SVS_850","I-SVS_870","I-SV_500","I-SV_550","I-TV_CLPS","I-VSS_000","I-VSS_020","I-VSS_040","I-VSS_060","I-VSS_080","I-VSS_100","I-VSS_120","I-VSS_140","I-VSS_160","I-VSS_180","I-VSS_200","I-VSS_220","I-VSS_240","I-VSS_260","I-VSS_280","I-VSS_300","I-VSS_320","I-VSS_340","I-VSS_360","I-VSS_380","I-VSS_400","I-VSS_420","I-VSS_440","I-VSS_460","I-VSS_480","I-VSS_500","I-VSS_550","I-VSS_600","I-VSS_620","I-VSS_650","I-VSS_700","I-VSS_700M","I-VSS_720","I-VSS_740","I-VSS_750","I-VSS_760","I-VSS_780","I-VSS_800","I-VSS_820","I-VSS_840","I-VSS_850","I-VSS_870","I-VSS_ZERO","I-VS_500","I-VS_570","I-VS_600","I-VS_650","I-X_BDBU_BUDW","L-PEC_NIL","L-PEC_NIL_NFB","L-PEC_X_6C_6G_6H","L-PEC_X_6C_6G_6H_NFB","N-ARTW_86","N-BADP","N-BALM_X8","N-CLCWG_63","N-CLCWG_X5","N-DPTX1-2","N-DPWG_63","N-JNWG_RADIAL","N-JNWL_63","N-JNWL_X5","N-LTWG_63","N-LTWG_X5","N-NIL","N-SOWL_79","N-STUBSF_ZERO","N-STUBSF_ZERO_INV","N-UGWL_7J","N-WAGGA_330_BUSA","N-WGWA_63","N-WGWA_63_X5","N-WGWA_X5","N-WG_BUR_IBR_0","N-WG_BUR_IBR_0100","N-WG_BUR_IBR_0200","N-WG_BUR_IBR_0300","N-WG_BUR_IBR_0400","N-WG_BUR_IBR_0500","N-WG_BUR_IBR_0600","N-WG_BUR_IBR_0700","N-WG_BUR_IBR_0800","N-WG_BUR_IBR_0900","N-WG_BUR_IBR_1000","N-WG_BUR_IBR_1100","N-WG_BUR_IBR_1200","N-WG_BUR_IBR_1300","N-WG_BUR_IBR_1400","N-WG_BUR_IBR_1500","N-WG_BUR_IBR_1600","N-WG_BUR_IBR_1700","N-WG_BUR_IBR_1800","N-WG_BUR_IBR_1900","N-WG_BUR_IBR_2000","N-WG_BUR_IBR_2100","N-WG_BUR_IBR_2200","N-WG_BUR_IBR_2300","N-WG_BUR_IBR_2400","N-WG_BUR_IBR_2500","N-WG_BUR_IBR_2600","N-WG_BUR_IBR_2700","N-WG_BUR_IBR_2800","N-WG_BUR_IBR_2900","N-WG_BUR_IBR_3000","N-WG_BUR_IBR_3100","N-WG_BUR_IBR_3200","N-WG_BUR_IBR_3300","N-WG_BUR_IBR_3400","N-WG_BUR_IBR_3500","N-WG_BUR_IBR_3600","N-WG_BUR_IBR_3700","N-WG_BUR_IBR_3800","N-WOLLARSF1_ZERO_INV","N-X_6C_6G_6H","N-X_94T+94M","N-X_BABU_BADP","N-X_DPTX1+2","N-X_TWNR_MORNR","NC-S_TB3B1","NC-V_WOORB1","NRM_NIL_ALL","Q-BCBS_820","Q-BCCP_812","Q-BCNE_821","Q-BCRG_811","Q-BCST","Q-BSNE","Q-BSNE_834","Q-BS_275BUS_CB","Q-CLST","Q-CLWU","Q-CL_275BUS_CB","Q-CN1000","Q-CPWU_818","Q-H13RS_SVC","Q-HAURS","Q-LCCP_8859","Q-NESTM","Q-NE_275BUS_CB","Q-RGLC_8875","Q-RS_275BUS_CB","Q-SMHAU","Q-SMRS","Q-SMRS_N-2","Q-SM_275BUS_CB","Q-ST_275BUS_CB","Q-X_2FNQ+3NQ+VC","Q-X_BSNE+CLST","Q-X_CLST+LCCP","S-ACPA","S-ACPA_BC-2CP","S-BG6538_6539_CB","S-BGBW","S-BRTX3","S-BWMP","S-BWMP_OFF","S-DAV_ROB_GEN_0","S-DAV_ROB_GEN_0100","S-DAV_ROB_GEN_0200","S-DAV_ROB_GEN_0300","S-DAV_ROB_GEN_0400","S-DAV_ROB_GEN_0500","S-DAV_ROB_GEN_0600","S-DAV_ROB_GEN_0700","S-DAV_ROB_GEN_0800","S-DAV_ROB_GEN_0900","S-DAV_ROB_GEN_1000","S-DAV_ROB_GEN_1100","S-DAV_ROB_GEN_1200","S-DAV_ROB_GEN_1300","S-DAV_ROB_GEN_1400","S-DAV_ROB_GEN_1500","S-MAMAP2","S-MAMAP2_BC-2CP","S-NIL","S-SMF1_BESS_BDU_ZERO","S-SMF2_BESS_BDU_ZERO","S-TB3_BESS_BDU_ZERO","S-TU_SE_GEN_0","S-TU_SE_GEN_0100","S-TU_SE_GEN_0200","S-TU_SE_GEN_0300","S-TU_SE_GEN_0400","S-TU_SE_GEN_0500","S-TU_SE_GEN_0600","S-TU_SE_GEN_0700","S-TU_SE_GEN_0800","S-TU_SE_GEN_0900","S-TU_SE_GEN_1000","S-TU_SE_GEN_1100","S-X_BWMP+MPPA","S-X_BWMP+MPPA_OFF","V-CPRC","V-DDTX1","V-DDTX1_DBUSS_T","V-DDTX2","V-DDTX2_DBUSS_T","V-DDTX3","V-DDWO_63","V-DDWO_X5","V-EL_ML_TG_GEN_0","V-EL_ML_TG_GEN_0100","V-EL_ML_TG_GEN_0200","V-EL_ML_TG_GEN_0300","V-EL_ML_TG_GEN_0400","V-EL_ML_TG_GEN_0500","V-EL_ML_TG_GEN_0600","V-EL_ML_TG_GEN_0700","V-EL_ML_TG_GEN_0800","V-EL_ML_TG_GEN_0900","V-EL_ML_TG_GEN_1000","V-EL_ML_TG_GEN_1100","V-EL_ML_TG_GEN_1200","V-EL_ML_TG_GEN_1300","V-EL_ML_TG_GEN_1400","V-EL_ML_TG_GEN_1500","V-EL_ML_TG_GEN_1600","V-EL_ML_TG_GEN_1700","V-NWVIC_GEN_0","V-NWVIC_GEN_0100","V-NWVIC_GEN_0200","V-NWVIC_GEN_0300","V-NWVIC_GEN_0400","V-NWVIC_GEN_0500","V-NWVIC_GEN_0600","V-NWVIC_GEN_0700","V-NWVIC_GEN_0800","V-NWVIC_GEN_0900","V-NWVIC_GEN_1000","V-NWVIC_GEN_1100","V-NWVIC_GEN_1200","V-NWVIC_GEN_1300","V-NWVIC_GEN_1400","V-NWVIC_GEN_1500","V-NWVIC_GEN_1600","V-NWVIC_GEN_1700","V-NWVIC_GEN_1800","V-NWVIC_GEN_1900","V-NWVIC_GEN_2000","V-NWVIC_GEN_2100","V-NWVIC_GEN_2200","V-NWVIC_GEN_2300","V-NWVIC_GEN_2400","V-NWVIC_GEN_2500","V-SWVIC_GEN_0","V-SWVIC_GEN_0100","V-SWVIC_GEN_0200","V-SWVIC_GEN_0300","V-SWVIC_GEN_0400","V-SWVIC_GEN_0500","V-SWVIC_GEN_0600","V-SWVIC_GEN_0700","V-SWVIC_GEN_0800","V-SWVIC_GEN_0900","V-SWVIC_GEN_1000","V-SWVIC_GEN_1100","V-SWVIC_GEN_1200","V-SWVIC_GEN_1300","V-SWVIC_GEN_1400","V-SWVIC_GEN_1500","V-SWVIC_GEN_1600","V-SWVIC_GEN_1700","V-SWVIC_GEN_1800","V-SWVIC_GEN_1900","V-SWVIC_GEN_2000","V-SWVIC_GEN_2100","V-SWVIC_GEN_2200","V-SWVIC_GEN_2300","V-SWVIC_GEN_2400","V-SWVIC_GEN_2500","V-SWVIC_GEN_2600","V-SWVIC_GEN_2700","V-SWVIC_GEN_2800","V-SWVIC_GEN_2900","V-SWVIC_GEN_3000","V-SWVIC_GEN_3100","V-SWVIC_GEN_3200","V-SWVIC_GEN_3300","V-SWVIC_GEN_3400","V-SWVIC_GEN_3500","V-SWVIC_GEN_3600","V-SWVIC_GEN_3700","V-SWVIC_GEN_3800","V-SWVIC_GEN_3900","V-TRGBESS1_BDU_ZERO","V-X_BAELML_BAML_B1CB"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the record for the given effective date","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"The person who authorised the constraint set","examples":["AASHFAQ","ABRAHAMY","AMULINGBAYAN","ANGROOM","ANL","BASHFORD","BATCH","BBLAKE","BCHHETRI","BOGDANV","BSANGHAVI","Batch","CPITT","CTOOMEY","DALJURE","DFARQUHAR","DGILMOUR","DHARVINL","DHOOLE","DPAT","FRANKB","GWEGENER","JAGUEST","JDUQUE","JHOO","JLOVERING","JRUFF","JWRIGHT","KHOUNSELL","KINW","KNGUYEN2","KPERERA","MATING","MBHASKAR","MINGCHENG","MJAMES2","MSHAKERI","MYANG","MYASAN","PARULS","RAMITHAW","RSHARMA2","RYANG","SHENGG","SNIEK","SPILLAY2","SRAJAPAKSE2","TERRYL","WSCHIE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time of authorising the constraint set","examples":["2026/09/01 02:06:54"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"COVERAGE":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"The region the constraint set is located in or a special grouping (e.g. CHIMERA)","examples":["CONSTRAINT AUTO","FCAS - GLOBAL","INTER-REGIONAL","NEGATIVE RESIDUE","NET SUPP AGREEMENTS","NON-CONFORMANCE","NSW1","QLD1","QUICK","SA1","TAS1","VIC1"]},"DESCRIPTION":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Description of the constraint","examples":[" 65_66 OL FOR 051 outage","0MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","0MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","0MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","0MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","0MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","0MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1000MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1000MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1000MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","100MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","100MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","100MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1100MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1100MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1100MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","1200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1200MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1200MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1300MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1300MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1400MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1400MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1500MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1500MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","1500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1600MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1600MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1700MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","1700MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1800MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","1900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","1900MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","1900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2000MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","200MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","200MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","200MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","2100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2100MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2200MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","2500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","2900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","2900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3000MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3000MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","300MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","300MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","300MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","300MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","3100MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3100MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3200MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3200MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3300MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3300MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","3800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","3900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","400MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","400MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","400MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","400MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","400MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","400MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","500MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","500MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","500MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","500MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","500MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","500MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","600MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","600MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","600MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","600MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","600MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","600MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","700MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","700MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","700MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","700MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","700MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","700MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","800MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","800MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","800MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","800MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","800MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","800MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","900MW upper limit on Dundonnell WF, Golden Plains WF, Hawkesdale WF, Macarthur WF, Mortlake BESS, Mortlake PS, Ryan Corner WF and Stockyard Hill WF.","900MW upper limit on Elaine WF, Moorabool WF, Mt Mercer WF, VBB BESS, Terang BESS, Berrybank 1 and 2 WF, Mortlake South WF, Oaklands Hill WF, Salt Creek WF, Mt Gelibrand WF","900MW upper limit on Hallet PS, Hallet WF, Goyder South WF, Hornsdale WF, Hornsdale BESS, North Brown Hill WF, Bluff WF, Willogoleche WF","900MW upper limit on IBR within North West Victoria (Bendigo-Ballarat-Red Cliffs 220kV area)","900MW upper limit on IBR within South West NSW (Buronga to Wagga area) ","900MW upper limit on Snuggery PS, Canunda WF, Lake Bonney WF, Lake Bonney BESS, Mannum SF, Mannum BESS, Ladbroke PS, Tailem Bend SF 1 & 2, Tailem Bend BESS 2 & 3","Avoid overload on line 8U for NIL trip","Constraint Automation Set.  Generated by RTCA[EMS] Host BNEREGEEMP5(EMPBRI)","Constraint Automation Set.  Generated by RTCA[EMS] Host BNEREGEEMP6(EMPBRI)","Constraint Automation Set.  Generated by STNET[BNECR4] Host NORREGEEMP7(EMPSYD)","Constraint Automation Set.  Generated by STNET[NORCR1] Host BNEREGEEMP5(EMPBRI)","Constraint Automation Set.  Generated by STNET[NORCR1] Host BNEREGEEMP5(EMPBRI) 65/66 Margine increased to 50","Direction - Energy - No Intervention Pricing","Direction to allow charge but zero discharge for Bluegrass BESS for Dispatch and Predispatch and NOT PASA ","Direction to allow charge but zero discharge for Broadsound BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Broken Hill BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Bungama BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Calala BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Calala BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Clements Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Eraring BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Eraring BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Horsham Renewable Energy Park BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Liddell BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Limondale BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Lincoln Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mannum Stage 2 BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A1  for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Melbourne Renewable Energy Hub A3 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mornington BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mortlake BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mugga Lane BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Mugga Lane BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for New England BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for New England BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Orana BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Pine Lodge BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Quorn Park BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Stanwell BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Summerfield BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Summerfield BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Supernode BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Tailem Bend 3 battery for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Templers BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Terang BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Williamsdale BESS for Dispatch and Predispatch and NOT PASA","Direction to allow charge but zero discharge for Woolooga BESS  for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Bluegrass BESS for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Broadsound BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Broken Hill BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Bungama BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Calala BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Calala BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Clements Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Eraring BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Eraring BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Horsham Renewable Energy Park BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Liddell BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Limondale BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Lincoln Gap BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mannum Stage 2 BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A1  for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Melbourne Renewable Energy Hub A3 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mornington BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mortlake BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mugga Lane BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Mugga Lane BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for New England BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for New England BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Orana BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Pine Lodge BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Quorn Park BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Stanwell BESS for Dispatch and Predispatch and NOT PASA ","Direction to zero charge and discharge for Summerfield BESS 1 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Summerfield BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Supernode BESS 2 for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Tailem Bend 3 battery for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Templers BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Terang BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Williamsdale BESS for Dispatch and Predispatch and NOT PASA","Direction to zero charge and discharge for Woolooga BESS for Dispatch and Predispatch and NOT PASA ","Discretionary upper limit for Summerfield 1 BESS of 0 MW","Discretionary upper limit for Summerfield 2 BESS of 0 MW","Discretionary upper limit for Tailem Bend 3 BESS of 0 MW","GPWF 1 and 2 and 3 East limited to 250 MW","Limit Murraylink + Heywood + PEC to zero in either direction","Limit PEC to zero in either direction","Loss of 66 O/L 65 Margine of 50","Loss of 72 Line O/L 947","MLTS-TGTS 220kV Line","Minimum unit target for DUID BARKIPS1 required to provide system security for SSM Contract TS1_S00007 on 29/09/2026 10:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 1/09/2026 12:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 11/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 12/09/2026 10:05:00 PM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 12/09/2026 9:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 15/09/2026 7:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 17/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 18/09/2026 11:05:00 PM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 18/09/2026 4:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 22/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 23/09/2026 8:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 24/09/2026 12:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 24/09/2026 8:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 25/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 26/09/2026 4:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 28/09/2026 9:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 4/09/2026 8:35:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 6/09/2026 9:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 7/09/2026 11:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 8/09/2026 11:05:00 AM","Minimum unit target for DUID PPCCGT required to provide system security for SSM Contract TS1_S00006 on 8/09/2026 9:05:00 PM","NSW to SA on PEC limited to 100 MW","NSW to SA on PEC limited to 150 MW","NSW to SA on PEC limited to 200 MW","NSW to SA on PEC limited to 250 MW","NSW to SA on PEC limited to 300 MW","NSW to SA on PEC limited to 350 MW","NSW to SA on PEC limited to 400 MW","NSW to SA on PEC limited to 450 MW","NSW to SA on PEC limited to 50 MW","NSW to SA on PEC limited to 500 MW","NSW to SA on PEC limited to 550 MW","NSW to SA on PEC limited to 600 MW","NSW to SA on PEC limited to 650 MW","NSW to SA on PEC limited to 700 MW","NSW to SA on PEC limited to 750 MW","NSW to SA on PEC limited to 800 MW","NSW1-QLD1 >= -429 (Ramping)","Negative Residue Management constraint set for V-SA, NSW1-QLD1, VIC1-NSW1, T-V-MNSP1 and NSW1-SA1","Non Conformance Constraint for TAILEM BEND 3 BESS","Non Conformance Constraint for WOOREEN BESS 1","Out = 6C, 6G, 6H 330kV lines","Out = 811 (H10 Bouldercombe to H73 Raglan) 275kV line","Out = 820 (H10 Bouldercombe to H20 Broadsound)  275kV line","Out = 821 275kV fdr H10 Bouldercombe - H11 Nebo","Out = 834 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 848 or 849 H10 Bouldercombe to H29 Stanwell 275 kV line","Out = 871 H24 Calvale to H40 Wurdong 275kV line","Out = 879 (H35 Strathmore to H91 Haughton) 275kV line","Out = 8846 or 8847 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 8857 or 8858 (H35 Strathmore to H13 Ross) 275kV line, CQ-NQ limits.","Out = 8874 or 8873 or 855 (H24 Calvale  to H29 Stanwell) 275kV feeder","Out = 8911 (H91 Haughton River to H13 Ross) 275kV line","Out = Armidale to Tamworth (86) line","Out = Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool","Out = Balranald to Buronga (X3) and Balranald to Darlington Point (X5) 220kV lines","Out = Balranald to Darlington Point (X5) 220kV line","Out = Balranald to Limondale 1 SF (X8) 220kV line","Out = Basslink Cable Load Prediction System (CLPS) dynamic rating data unavailable. Basslink limited to continuous ratings","Out = Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Blyth West- Munno Para 275kV line and Munno Para-Para 275kV (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Bungama - Blyth West 275kV line O/S, (Blyth West trip scheme I/S)","Out = Carwarp to Red Cliffs 220kV line","Out = Darlington Point 330/132 kV Transformer #1 and #2","Out = Dederang to Wodonga 330kV line O/S, 63 330kV line opened, X5 in service. See OM 526 and OM 608","Out = Dederang to Wodonga 330kV line O/S, X5 opened. See OM 526 and OM 608","Out = Jindera to Wodonga (060) line, Wagga-Yass 132kV network Split, 63 de-energised, X5 in service","Out = Jindera to Wodonga (060) line, Wagga-Yass 132kV network Split, X5 opened, 63 I/S","Out = Lower Tumut to Wagga (051) 330kV line, Wagga-Yass 132kV split, 9R3 + 9R4 + 63 open, and with 2 Yass Transformer in service","Out = Lower Tumut to Wagga (051) 330kV line, Wagga-Yass 132kV split, 9R3 + 9R4 + X5 open, and with 2 Yass Transformer in service","Out = Nil, NSW System Normal","Out = Nil, SA System Normal","Out = Nil, loss of both 8857 and 8858 (H35 Strathmore to H13 Ross) 275kV lines declared a credible contingency","Out = One 275kV Bus or one or more CB (89052,5812) at H13 Ross","Out = One H11 Nebo to H35 Strathmore 275KV line (822 / 878 / 8845)","Out = both Bundey to Buronga (6C and 6F) and both Buronga to Dinawan (6G and 6H) 330kV lines","Out = one 275kV Bus or one or more 275kV CB (88732,CB 88312,CB8492, CB8612, CB88742, CB8622, CB8632, CB8642, CB8562, CB8552) at Stanwell (H29)","Out = one 275kV Bus or one or more 275kV CB (CB8522, CB8712) at Calvale (H24)","Out = one 275kV Bus or one or more CB (CB8202, CB8342, CB88472, CB88312, CB8562, CB8332) at Broadsound (H20) ","Out = one 275kV Bus or one or more CB(8792,88452,88572,8782) at Strathmore (H35)","Out = one 275kV bus or one or more CB (8342,8222) at H11 Nebo","Out = one H20 Broadsound - H11 Nebo (834, 8846, 8720, 8846+8720, 8847) + one H24 Calvale - H29 Stanwell (855, 8873, 8874) 275kV line","Out = one H24 Calvale - H29 Stanwell (855, 8873, 8874) + H58 Larcom Creek - H67 Calliope River (8859) 275kV line","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series capacitors I/S)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series caps O/S)","Out= 818 H67 Calliope River to H40 Wurdong 275kV feeder, CQ-SQ voltage stability limit","Out= 8875 (H73 Raglan to H58 Larcom Creek) 275kV line","Out= 968 (Tamworth to Narrabri) and 96M(Narrabri to Moree) 132kV line","Out= Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Blyth West- Munno Para 275kV line and Munno Para-Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Bouldercombe to Calliope River (812), thermal limit equations for 811, 871 and 8859.","Out= Brinkworth 275/132kV TX3 transformer (with/without associated CBs 6530 & 6528& 6093 & 6068 OPEN).","Out= Bungama 275kV CB CB6538 OR CB6539 (NOTE: Only one CB O/S at a given time)","Out= Darlington Point to Wagga (63) 330kV line + 99J,99D,99L,9R4 opened","Out= Dederang H1 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Dederang H2 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= H13 Ross 275 kV SVC","Out= Larcom Creek to Calliope River (8859) 275kV line","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3)); (Both Black Range series capacitors O/S)","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3); (Both Black Range series capacitors I/S)","Out= Molong to Orange North (94T) 132kV line and Beryl to Crudine Ridge 132kV line (94M)","Out= Stubbo to Uungula (79) 330kV line","Out= Uungula to Wellington (7J) 330kV line","Out= one Darlington Pt 132/330kV TX1 or TX2","Out= up to two non-parallel 275kV lines between Ross-Woree, up to three non-parallel 275kV lines between Calvale-Ross, one/more 275kV bus or CB at H24 Calvale, H10 Bouldercombe, H29 Stanwell, H20 Broadsound, H11 Nebo, H35 Strathmore, H13 Ross, Ross SVC","Out=MLTS-TGTS 220kV line, trip of BATS-MLTS2 220kV line O/L BATS-MLTS1 220kV line","Out=MLTS-TGTS 220kV line, trip of BATS-MLTS2 220kV line O/L ELTS-MLTS 220kV line","Out=PEC loop closed, N-3 outages around PEC loop, 6C or 6F line plus 330 kV connection between Wagga and Buronga open. Feedback DS formulation","Out=PEC loop closed, N-3 outages around PEC loop, 6C or 6F line plus 330 kV connection between Wagga and Buronga open. Non-feedback DS formulation","Out=PEC loop closed, NIL major outages around PEC loop. Feedback DS formulation","Out=PEC loop closed, NIL major outages around PEC loop. Non-feedback DS formulation","Out=Wagga 330kV bus A. (Note: Wagga-Yass 132kV network split, X5 opened, with 2 Yass Transformer in service, Wagga-Darlington Pt open via 63 or 9R3+9HR+9HT)","Outage = Culcairn to Wagga (3G) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Outage = Culcairn to Wagga (3G) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Outage = Culcairn to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Outage = Culcairn to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Outage = Dederang No.1 330/220kV transformer","Outage = Dederang No.2 330/220kV transformer","Outage = Dederang No.3 330/220kV transformer","Outage = Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, Darlington Point-Wagga 132kV split, X5 + 63 + 9R4 + 996 open","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, 63 Open, 9R4 Open, and with 2 Yass TXs in service","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 Open, 9R4 Open, and with 2 Yass TXs in service","Outage =Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 and 63 Open, 9R4 Open, and with 2 Yass TXs in service","QLD security issue","Qld CQ-NQArea Trf<=1000MW(Nebo+Dys);","Quick Constraint for energy","Quick Constraint for energy - Golden Plains EAST 1+2+3 Gen Requested lilimation","Quick Constraint for energy _Participant requested limitation of GPWF 1 and 2 and 3 East for 250MW for Testing","Quick constraint for Energy","Ramping Set for #VIC1_E_20260916 on 17/09/2026","Ramping Set for F-I_ML_APD_LOAD on 02/09/2026","Ramping Set for I-BURC_X1 on 01/09/2026","Ramping Set for I-BURC_X1 on 12/09/2026","Ramping Set for I-BURC_X1 on 14/09/2026","Ramping Set for I-BURC_X9 on 20/09/2026","Ramping Set for I-BURC_X9 on 21/09/2026","Ramping Set for I-HYSE on 07/09/2026","Ramping Set for I-HYSE on 09/09/2026","Ramping Set for I-ML_SV_EQ_020 on 02/09/2026","Ramping Set for I-ML_VS_EQ_020 on 02/09/2026","Ramping Set for I-ML_ZERO on 02/09/2026","Ramping Set for I-SVML_050 on 02/09/2026","Ramping Set for I-VSML_050 on 02/09/2026","Ramping Set for I-X_BABU_BURC on 12/09/2026","Ramping Set for I-X_BABU_BURC on 14/09/2026","Ramping Set for I-X_BDBU_BUDW on 28/09/2026","Ramping Set for N-966+KK on 08/09/2026","Ramping Set for N-ARTW_86 on 29/09/2026","Ramping Set for N-AVDT_10 on 20/09/2026","Ramping Set for N-BABU on 12/09/2026","Ramping Set for N-BADP on 04/09/2026","Ramping Set for N-BAMB_132_OPEN on 20/09/2026","Ramping Set for N-BANCO_973 on 17/09/2026","Ramping Set for N-BANCO_999 on 10/09/2026","Ramping Set for N-BANGOWF1_ZERO on 17/09/2026","Ramping Set for N-BANYS_9GL on 17/09/2026","Ramping Set for N-BECRD_94M on 14/09/2026","Ramping Set for N-BECRD_94M on 21/09/2026","Ramping Set for N-BU_CB7012 on 01/09/2026","Ramping Set for N-BWLD_ONE on 14/09/2026","Ramping Set for N-BWLD_ONE on 16/09/2026","Ramping Set for N-CHKS_ONE on 04/09/2026","Ramping Set for N-CHRL_9W3 on 05/09/2026","Ramping Set for N-CNCW_6_15M on 01/09/2026","Ramping Set for N-CNCW_6_15M on 09/09/2026","Ramping Set for N-CNCW_6_15M on 29/09/2026","Ramping Set for N-CRDMP-9ML on 27/09/2026","Ramping Set for N-CRWF1_ZERO on 27/09/2026","Ramping Set for N-DBWL_ONE on 08/09/2026","Ramping Set for N-DBWL_ONE on 09/09/2026","Ramping Set for N-DM_SVC on 29/09/2026","Ramping Set for N-DPTX1-2 on 07/09/2026","Ramping Set for N-DPTX1-2 on 14/09/2026","Ramping Set for N-DPYC-99D-C on 01/09/2026","Ramping Set for N-DP_TIETX on 21/09/2026","Ramping Set for N-DTKV_18_WG_CLOSE on 27/09/2026","Ramping Set for N-DTKV_18_WG_OPEN on 04/09/2026","Ramping Set for N-DTMN_8_15M on 14/09/2026","Ramping Set for N-DTSS_11 on 18/09/2026","Ramping Set for N-DTSS_11 on 19/09/2026","Ramping Set for N-ERA2_BESS_BDU_ZERO on 11/09/2026","Ramping Set for N-ERNC_90 on 13/09/2026","Ramping Set for N-ERVY_25 on 01/09/2026","Ramping Set for N-FINLYSF1_ZERO_INV on 04/09/2026","Ramping Set for N-GNNDHSF1_ZERO_INV on 10/09/2026","Ramping Set for N-GNNDHSF1_ZERO_INV on 13/09/2026","Ramping Set for N-KCMA_37 on 23/09/2026","Ramping Set for N-KKLS_967 on 07/09/2026","Ramping Set for N-KKLS_967 on 08/09/2026","Ramping Set for N-KS_132BS1 on 22/09/2026","Ramping Set for N-KS_132BS3 on 23/09/2026","Ramping Set for N-KVCW_3W_WG_CLOSE on 09/09/2026","Ramping Set for N-LDNC_81 on 22/09/2026","Ramping Set for N-LDTM_82 on 21/09/2026","Ramping Set for N-LDTW_84 on 29/09/2026","Ramping Set for N-LSLS_9U8 on 21/09/2026","Ramping Set for N-LS_VC1 on 21/09/2026","Ramping Set for N-LTWG_X5 on 04/09/2026","Ramping Set for N-MBTE_1 on 13/09/2026","Ramping Set for N-MORBOR on 02/09/2026","Ramping Set for N-MORBOR on 03/09/2026","Ramping Set for N-MORBOR on 08/09/2026","Ramping Set for N-MORBOR on 09/09/2026","Ramping Set for N-MORBOR on 13/09/2026","Ramping Set for N-MORBOR on 16/09/2026","Ramping Set for N-MORBOR on 22/09/2026","Ramping Set for N-MORBOR on 30/09/2026","Ramping Set for N-MPTX on 13/09/2026","Ramping Set for N-MPTX on 27/09/2026","Ramping Set for N-MPWO_5A5 on 24/09/2026","Ramping Set for N-NAGU on 23/09/2026","Ramping Set for N-NESBESS_BDU_ZERO on 16/09/2026","Ramping Set for N-SDUT_1 on 14/09/2026","Ramping Set for N-STUBSF_ZERO on 28/09/2026","Ramping Set for N-STUBSF_ZERO_INV on 28/09/2026","Ramping Set for N-SWVY_29 on 03/09/2026","Ramping Set for N-SWVY_29 on 25/09/2026","Ramping Set for N-TAGU_969 on 02/09/2026","Ramping Set for N-TAGU_969 on 03/09/2026","Ramping Set for N-TWNR_968 on 22/09/2026","Ramping Set for N-TW_330_BUS1 on 30/09/2026","Ramping Set for N-TW_SVC on 27/09/2026","Ramping Set for N-TW_SVC on 30/09/2026","Ramping Set for N-WLMO_945 on 28/09/2026","Ramping Set for N-WLMP_72 on 20/09/2026","Ramping Set for N-WLWLSF1_ZERO on 07/09/2026","Ramping Set for N-WOLLARSF1_ZERO on 28/09/2026","Ramping Set for N-WOLLARSF1_ZERO_INV on 28/09/2026","Ramping Set for N-WOODLWN1_ZERO on 07/09/2026","Ramping Set for N-WSTWYSF_ZERO on 13/09/2026","Ramping Set for N-WYASF1_ZERO on 13/09/2026","Ramping Set for N-X_6+DDSM on 29/09/2026","Ramping Set for N-X_966+KK+CH_CB892A on 09/09/2026","Ramping Set for N-X_BADP_DTKV on 04/09/2026","Ramping Set for N-X_BU_SC_4_5 on 12/09/2026","Ramping Set for N-X_TWNR_MORNR on 22/09/2026","Ramping Set for N-YCNA_9HT_C on 01/09/2026","Ramping Set for Q-810_PARALLEL_CLOSE on 30/09/2026","Ramping Set for Q-B2PSBRA_8840 on 02/09/2026","Ramping Set for Q-BKRL_8818 on 08/09/2026","Ramping Set for Q-BK_VC on 30/09/2026","Ramping Set for Q-BOUL_BESS_BDU_ZERO on 14/09/2026","Ramping Set for Q-BSNE on 06/09/2026","Ramping Set for Q-CLBTX on 01/09/2026","Ramping Set for Q-CLBTX on 03/09/2026","Ramping Set for Q-CN1000 on 11/09/2026","Ramping Set for Q-CN1000 on 15/09/2026","Ramping Set for Q-CN1000 on 16/09/2026","Ramping Set for Q-CPWO_BI_INTACT on 21/09/2026","Ramping Set for Q-CYPW on 15/09/2026","Ramping Set for Q-GLD4_0 on 21/09/2026","Ramping Set for Q-H11NE_SVC on 15/09/2026","Ramping Set for Q-H11NE_SVC on 16/09/2026","Ramping Set for Q-H11NE_SVC on 30/09/2026","Ramping Set for Q-H13RS_SVC on 15/09/2026","Ramping Set for Q-H13RS_SVC on 16/09/2026","Ramping Set for Q-H13RS_SVC on 23/09/2026","Ramping Set for Q-H35STM_SVC on 11/09/2026","Ramping Set for Q-H35STM_SVC on 21/09/2026","Ramping Set for Q-H35STM_SVC on 24/09/2026","Ramping Set for Q-HATR on 08/09/2026","Ramping Set for Q-HATR on 09/09/2026","Ramping Set for Q-HATR on 27/09/2026","Ramping Set for Q-KMBG_7184 on 07/09/2026","Ramping Set for Q-LCCP_8859 on 20/09/2026","Ramping Set for Q-LV_275_BUS_TX_2 on 24/09/2026","Ramping Set for Q-LV_275_BUS_TX_2 on 25/09/2026","Ramping Set for Q-MEBK_802 on 02/09/2026","Ramping Set for Q-MRTA_732 on 03/09/2026","Ramping Set for Q-MSPTS_7243 on 08/09/2026","Ramping Set for Q-NESTM on 11/09/2026","Ramping Set for Q-OKTA_7246 on 03/09/2026","Ramping Set for Q-OKTA_7247 on 09/09/2026","Ramping Set for Q-OKTA_7247 on 14/09/2026","Ramping Set for Q-PWSP_808 on 08/09/2026","Ramping Set for Q-PWSP_808 on 21/09/2026","Ramping Set for Q-RLSP_809 on 15/09/2026","Ramping Set for Q-SMSPL on 27/09/2026","Ramping Set for Q-SPL_TX_1 on 27/09/2026","Ramping Set for Q-SPL_TX_2 on 27/09/2026","Ramping Set for Q-STR_ALDSF_ZERO on 06/09/2026","Ramping Set for Q-STR_MOUSF1_ZERO on 24/09/2026","Ramping Set for Q-STR_MOUSF1_ZERO on 25/09/2026","Ramping Set for Q-TRME on 02/09/2026","Ramping Set for Q-TRME on 07/09/2026","Ramping Set for Q-TRME on 14/09/2026","Ramping Set for Q-TRME on 20/09/2026","Ramping Set for Q-TRME on 24/09/2026","Ramping Set for Q-TR_TG_842 on 20/09/2026","Ramping Set for Q-TR_TG_843 on 08/09/2026","Ramping Set for Q-TR_TG_844 on 06/09/2026","Ramping Set for Q-WOCY on 28/09/2026","Ramping Set for Q-WOCY on 29/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 11/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 15/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 16/09/2026","Ramping Set for Q-X_2FNQ+3NQ+VC on 23/09/2026","Ramping Set for Q-X_BSNE+CLST on 14/09/2026","Ramping Set for Q-X_BSNE_NESM on 11/09/2026","Ramping Set for Q-X_CLST+LCCP on 20/09/2026","Ramping Set for Q-X_HATR_TWO on 01/09/2026","Ramping Set for Q-X_HATR_TWO on 02/09/2026","Ramping Set for Q-X_HATR_TWO on 03/09/2026","Ramping Set for Q-X_HATR_TWO on 08/09/2026","Ramping Set for Q-X_HATR_TWO on 09/09/2026","Ramping Set for Q-X_METR+BKME on 02/09/2026","Ramping Set for Q-X_NE_STM_SVC on 15/09/2026","Ramping Set for Q-X_NE_STM_SVC on 16/09/2026","Ramping Set for Q-X_NE_STM_SVC on 30/09/2026","Ramping Set for Q-X_PWSP_CPWO on 21/09/2026","Ramping Set for Q-X_PWSP_CPWO_O on 23/09/2026","Ramping Set for Q-X_RS_TX_TX_C on 22/09/2026","Ramping Set for Q-X_RS_TX_TX_C on 25/09/2026","Ramping Set for Q-X_TRME_TRME on 07/09/2026","Ramping Set for Q-X_WOPW_WOGG_CL on 29/09/2026","Ramping Set for S-ACMA on 02/09/2026","Ramping Set for S-BC_CP on 05/09/2026","Ramping Set for S-BC_CP on 06/09/2026","Ramping Set for S-BC_CP on 07/09/2026","Ramping Set for S-BC_CP on 11/09/2026","Ramping Set for S-BC_CP on 12/09/2026","Ramping Set for S-BC_CP on 13/09/2026","Ramping Set for S-BC_CP on 15/09/2026","Ramping Set for S-BC_CP on 21/09/2026","Ramping Set for S-BG6538_6539_CB on 27/09/2026","Ramping Set for S-BG6538_6539_CB on 28/09/2026","Ramping Set for S-BRDV on 16/09/2026","Ramping Set for S-BR_CB6071 on 30/09/2026","Ramping Set for S-CGMS on 12/09/2026","Ramping Set for S-CGMS on 13/09/2026","Ramping Set for S-CGTI on 07/09/2026","Ramping Set for S-CGTI on 21/09/2026","Ramping Set for S-CGTI on 30/09/2026","Ramping Set for S-DC_CBG3 on 02/09/2026","Ramping Set for S-DVTX on 07/09/2026","Ramping Set for S-DVTX on 22/09/2026","Ramping Set for S-KHKN_BC-2CP on 05/09/2026","Ramping Set for S-KHKN_BC-2CP on 06/09/2026","Ramping Set for S-MGTI on 16/09/2026","Ramping Set for S-MGTI on 17/09/2026","Ramping Set for S-MSTU on 20/09/2026","Ramping Set for S-MWP3RB on 27/09/2026","Ramping Set for S-MWPS2-MWPS3 on 02/09/2026","Ramping Set for S-MWPS2-MWPS3 on 15/09/2026","Ramping Set for S-MWPS3-PV_0 on 22/09/2026","Ramping Set for S-NWCB6024+23 on 12/09/2026","Ramping Set for S-NWCB6024+23 on 15/09/2026","Ramping Set for S-NWCB6024+23 on 23/09/2026","Ramping Set for S-NWCB6024+23 on 27/09/2026","Ramping Set for S-NWCB6024+23 on 30/09/2026","Ramping Set for S-NWRB2 on 02/09/2026","Ramping Set for S-NWRB2 on 12/09/2026","Ramping Set for S-NWRB2 on 15/09/2026","Ramping Set for S-NWRB2 on 23/09/2026","Ramping Set for S-NWRB2 on 27/09/2026","Ramping Set for S-NWRB2 on 30/09/2026","Ramping Set for S-PATW on 22/09/2026","Ramping Set for S-PA_CB6509 on 06/09/2026","Ramping Set for S-PA_VC1 on 06/09/2026","Ramping Set for S-PA_VC1_BC-2CP on 06/09/2026","Ramping Set for S-SECB6611_10 on 16/09/2026","Ramping Set for S-SECB6611_10_BC-2CP on 21/09/2026","Ramping Set for S-SE_VC1 on 16/09/2026","Ramping Set for S-SE_VC1 on 18/09/2026","Ramping Set for S-SE_VC1 on 22/09/2026","Ramping Set for S-SE_VC1_BC-2CP on 21/09/2026","Ramping Set for S-TB2_TX on 07/09/2026","Ramping Set for S-TB2_TX on 21/09/2026","Ramping Set for S-TB2_TX on 30/09/2026","Ramping Set for S-TBSE on 07/09/2026","Ramping Set for S-TBSE on 11/09/2026","Ramping Set for S-TBSE on 12/09/2026","Ramping Set for S-TBSE on 13/09/2026","Ramping Set for S-TBSE on 15/09/2026","Ramping Set for S-TBSE on 21/09/2026","Ramping Set for S-TB_CB6123 on 16/09/2026","Ramping Set for S-TB_CB6536 on 02/09/2026","Ramping Set for S-TIBAT1_0 on 06/09/2026","Ramping Set for S-TINO3 on 22/09/2026","Ramping Set for S-TINO3 on 27/09/2026","Ramping Set for S-TITN1 on 22/09/2026","Ramping Set for S-TPBAT_0 on 27/09/2026","Ramping Set for S-TPBAT_0 on 28/09/2026","Ramping Set for S-X_BWMP+MPPA on 22/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 22/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 23/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 24/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 27/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 29/09/2026","Ramping Set for T-BUSH_220_WCP_OPEN on 30/09/2026","Ramping Set for T-CSLI on 22/09/2026","Ramping Set for T-FATI on 27/09/2026","Ramping Set for T-GTSH on 15/09/2026","Ramping Set for T-HAPM_220 on 25/09/2026","Ramping Set for V-APHY_1 on 21/09/2026","Ramping Set for V-BALL_BESS_BDU_ZERO on 14/09/2026","Ramping Set for V-CPRC on 20/09/2026","Ramping Set for V-CPRC on 21/09/2026","Ramping Set for V-DBUSS_L on 02/09/2026","Ramping Set for V-DBUSS_L on 03/09/2026","Ramping Set for V-DBUSS_L on 04/09/2026","Ramping Set for V-DBUSS_L on 09/09/2026","Ramping Set for V-DBUSS_L on 10/09/2026","Ramping Set for V-DBUSS_L on 29/09/2026","Ramping Set for V-DBUSS_T on 02/09/2026","Ramping Set for V-DBUSS_T on 03/09/2026","Ramping Set for V-DBUSS_T on 04/09/2026","Ramping Set for V-DBUSS_T on 29/09/2026","Ramping Set for V-DDMS on 09/09/2026","Ramping Set for V-DDMS on 10/09/2026","Ramping Set for V-DDSM on 07/09/2026","Ramping Set for V-DDSM on 08/09/2026","Ramping Set for V-DDSM on 29/09/2026","Ramping Set for V-GNPL on 22/09/2026","Ramping Set for V-HM_VIC_ZERO on 03/09/2026","Ramping Set for V-HWRO3 on 03/09/2026","Ramping Set for V-HWRO3 on 13/09/2026","Ramping Set for V-HWSM on 01/09/2026","Ramping Set for V-HWSM on 02/09/2026","Ramping Set for V-HWSM on 04/09/2026","Ramping Set for V-HWSM on 05/09/2026","Ramping Set for V-HWSM on 06/09/2026","Ramping Set for V-HWSM on 17/09/2026","Ramping Set for V-HYTX_M12 on 22/09/2026","Ramping Set for V-HYTX_M12 on 27/09/2026","Ramping Set for V-HYTX_M12 on 28/09/2026","Ramping Set for V-LAVNTH1_ZERO on 04/09/2026","Ramping Set for V-LAVNTH1_ZERO on 05/09/2026","Ramping Set for V-LAVNTH1_ZERO on 18/09/2026","Ramping Set for V-LAVNTH1_ZERO on 19/09/2026","Ramping Set for V-LYPSA4_ZERO on 11/09/2026","Ramping Set for V-MLTX_A2 on 01/09/2026","Ramping Set for V-MTGELIBRAND_66 on 08/09/2026","Ramping Set for V-MTGELIBRAND_66 on 13/09/2026","Ramping Set for V-MTGELIBRAND_66 on 14/09/2026","Ramping Set for V-MTGELIBRAND_66 on 27/09/2026","Ramping Set for V-MTGELIBRAND_66 on 28/09/2026","Ramping Set for V-MTGELIBRAND_66 on 29/09/2026","Ramping Set for V-RANGEB_BDU_ZERO on 06/09/2026","Ramping Set for V-ROSM on 11/09/2026","Ramping Set for V-ROSM on 16/09/2026","Ramping Set for V-ROSM on 27/09/2026","Ramping Set for V-SALTCREEK_ZERO on 07/09/2026","Ramping Set for V-SMTX_F_R on 21/09/2026","Ramping Set for V-TRTS_BUS_CB_500 on 03/09/2026","Ramping Set for V-TSTT_R on 09/09/2026","Reference set to check system quantity, constraint never to bind","SA to NSW on PEC limited to 100 MW","SA to NSW on PEC limited to 150 MW","SA to NSW on PEC limited to 200 MW","SA to NSW on PEC limited to 250 MW","SA to NSW on PEC limited to 300 MW","SA to NSW on PEC limited to 350 MW","SA to NSW on PEC limited to 400 MW","SA to NSW on PEC limited to 450 MW","SA to NSW on PEC limited to 50 MW","SA to NSW on PEC limited to 500 MW","SA to NSW on PEC limited to 550 MW","SA to NSW on PEC limited to 600 MW","SA to NSW on PEC limited to 650 MW","SA to NSW on PEC limited to 700 MW","SA to NSW on PEC limited to 750 MW","SA to NSW on PEC limited to 800 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 0 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 100 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 120 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 140 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 160 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 180 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 20 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 200 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 220 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 240 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 260 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 270 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 280 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 300 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 340 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 350 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 40 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 400 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 420 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 450 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 470 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 500 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 520 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 540 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 550 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 560 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 580 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 60 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 600 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 620 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 640 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 650 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 660 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 680 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 700 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 720 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 740 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 750 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 760 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 780 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 80 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 800 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 820 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 840 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 850 MW","SA to Vic/NSW on Heywood + ML + PEC upper transfer limit of 870 MW","SA to Victoria on VicSA upper transfer limit of 500 MW","SA to Victoria on VicSA upper transfer limit of 550 MW","Stubbo #1 + #2 solar farm upper limit of 0 MW","Stubbo #1 + #2 solar farm upper limit of 0 MW and 0 Inverter","Terang BESS BDU zero Energy and FCAS","Vic/NSW to SA on Heywood + ML + PEC Minimum transfer limit of 700 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 0 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 100 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 120 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 140 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 160 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 180 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 20 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 200 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 220 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 240 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 260 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 280 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 300 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 320 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 340 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 360 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 380 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 40 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 400 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 420 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 440 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 460 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 480 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 500 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 550 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 60 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 600 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 620 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 650 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 700 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 720 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 740 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 750 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 760 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 780 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 80 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 800 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 820 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 840 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 850 MW","Vic/NSW to SA on Heywood + ML + PEC upper transfer limit of 870 MW","Victoria to SA on VicSA upper transfer limit of 500 MW","Victoria to SA on VicSA upper transfer limit of 570 MW","Victoria to SA on VicSA upper transfer limit of 600 MW","Victoria to SA on VicSA upper transfer limit of 650 MW","Wollar solar farm upper limit of 0 MW and 0 Inverter"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true},"MODIFICATIONS":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Details of the changes made to this version of the constraint set","examples":["Added  I_6F_NS_150 and I_6F_SN_150 and UFLS, ROCOF and OFGS from NIL sets. CCR10268","Added FCAS zero equations, CCR10234","Added MW/inverter conversion capping limit for Broken Hill BESS and Limondale BESS. CCR10223","Added MW/inverter conversion capping limit for Broken Hill BESS, Darling Point BESS, Limondale BESS, Riverina 1 & 2 BESS. CCR10223","Added MW/inverter conversion capping limit for Darling Point BESS, Riverina 1 & 2 BESS. CCR10223","Added MW/inverter conversion capping limit for Limondale BESS. CCR10223","Added PEC-2 NRM constraints. CCR10276","Added inverter indication equation for Carwarp SF; CCR10253","Added new thermal constraints managing txfmr flow from 220 to 330kV. CCR10212","Added new thermal equation. CCR10230","Added thermal equations monitoring line 85. CCR10272","Added voltage stability constraints per ElectraNet Mid-North 132kV Network Limit Advice (02/07/26). Updated thermal equations to include recently commissioned generators and added new thermal equations. Modified set and outage description. CCR10233","Added voltage stability constraints to set as per ElectraNet's Mid-north 132kV Network limit advice dated 02/07/26. Updated thermal equations in the set to include Tailem Bend 3 BESS and added new thermal equation.CCR10255","Added voltage stability constraints to set as per ElectraNet's Mid-north 132kV Network limit advice dated 02/07/26. Updated thermal equations in the set to include recently commissioned generators.CCR10227","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+2) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+3) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+3) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC. ","CCR10205. Updated system strength equations with new IDs.  A50 Region(1+4) +A17.b+A17.c NQLD SSI outage advice rev30 and NQ WAMPAC.","CCR10207 Add renamed system strength genconid","CCR10207 add renamed system strength equations","CCR10208 New","CCR10209 add renamed system strength genconid","CCR10216 Update NQLD system strength equations as per A38.d","Constraints updated to reflect latest advice on continuous ratings. Limits advice 21/5/26. CCR10202","Moved I_6F_NS_150 and I_6F_SN_150 to I-X_BDBU_BUDW. CCR10268","Moved UFLS, ROCOF and OFGS to I-X_BDBU_BUDWt. CCR10268","NEW","NEW; CCR10217","NSW,CCR10238","New","New DATASNAP INFO constraints for tracking Buronga PST tap positions; CCR10263","New DATASNAP constraints to track VIC and SA non forecast loads; CCR10271","New constraints for loop constraint LHS and RHS tracking; CCR10225","New set for PEC2 commissioning - based on I-BDBU_ONE. CCR10243","New, CCR10218","New, CCR10219","New, CCR10220","New, CCR10221","New, CCR10236","New, CCR10246","New, CCR10248","New, CCR10260","New, OM521, CCR10235","New. CCR10204","New. CCR10244","New. Includes  voltage stability limits as per ElectraNet's Mid-north 132kV Network limit advice- Ref to Viet Trinh email on 23/9/26. CCR10252","New; CCR10222","New; CCR10231","Removed N^^N_LTWG (not required until PEC2 energisation). CCR10264","Updated as per TG limit advice 23/09/2026, CCR10249","Updated description","Updated description only. CCR10235","Updated for PEC registration. CCR10250","Updated for PEC-2. CCR10250","Updated for PEC2 commissioning. CCR10247","Updated set description","Using DATA_MMS_ALERT1 to allow invocation of constraint prior to 1 Oct 2026. CCR10248"]},"OUTAGE":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Detail of the plant that is not in service","examples":[" * No transmission outages"," * discretionary upper limit for Laverton North Unit 1"," * discretionary upper limit for Loy Yang A Unit 4"," * discretionary upper limits for West Wyalong SF Generation"," * discretionary upper limits for Woodlawn Generation"," Dederang No.1 330/220kV transformer"," Dederang No.2 330/220kV transformer"," Dederang No.3 330/220kV transformer","* Discretionary upper limits for Hume VIC Generation","051 (Lower Tumut to Wagga) 330kV line 0/S, Wagga-Yass 132kV split, 9R3 + 9R4 + 63 open, and with 2 Yass Transformer in service","051 (Lower Tumut to Wagga) 330kV line 0/S, Wagga-Yass 132kV split, 9R3 + 9R4 + X5 open, and with 2 Yass Transformer in service","060 (Jindera to Wodonga) 330kV line O/S","33 or 34 (Bayswater to Liddell) 330kV line O/S, one line O/S only","7184 Kamerunga Barron Gorge PS 132kV line","7189 or 795 (T70 Cooroy to H9 Palmwood) 132kV feeder (section 1 or 2 or both)","7457(H35 Strathmore to T242 Springlands) 132kV line O/S","808 (H2 South Pine to H9 Palmwoods) 275 kV feeder O/S","808 (H9 Palmwoods to H2 South Pine) + 813 or 814 (H67 Calliope River to H5 Woolooga) 275kV lines","808 (H9 Palmwoods to H2 South Pine) + 813 or 814 (H67 Calliope River to H5 Woolooga) 275kV lines. Assume 132kV/110kV parallel between Woolooga - South Pine OPEN.","809 H16 Rocklea to H2 South Pine 275 kV feeder O/S","81 (Liddell to Newcastle) 330kV line","810 (H5 Woolooga to H9 Palmwoods) 275kV line+ 813/2 or 814/2 or 8850 ( H5 Woolooga to H6 Gin Gin or H63 Teebar Creek) 275kV lines","810 H9 Palmwoods to H5 Woolooga 275 kV feeder O/S with parallel 132 kV network intact","818 H67 Calliope River to H40 Wurdong 275kV feeder O/S","82 Liddell to Tomago 330kV line","837 and 8812 H18 Tarong to H12 Mt England 275 kV feeders O/S","837 or 8812 H18 Tarong to H12 Mt England 275 kV feeder O/S","84 (Liddell to Tamworth) 330kV line O/S","86 (Armidale to Tamworth) 330kV line O/S","871 H24 Calvale to H40 Wurdong 275kV line","879 (H35 Strathmore to H91 Haughton) 275kV line O/S","8818 H36 Blackwall to H16 Rocklea 275 kV feeder O/S","8857 or 8858 (H35 Strathmore to H13 Ross) 275kV line O/S","8911 (H91 Haughton River to H13 Ross) 275kV line O/S","967 (Koolkhan to Lismore) 132kV line O/S","9U8 or 9U9 or 9W1 132kV lines O/S","9W3 (Coffs Harbour to Raleigh) 132kV line O/S. Note: Auto detect PST status included","Alcoa Portland to Heywood No. 1 500 kV line only","Any 275 kV line between H24 Calvale  to H29 Stanwell outage","Any one 834, 8846, 8720, 8846+8720, 8847 (H20 Broadsound - H11 Nebo) + any one 855, 8873, 8874 (H24 Calvale - H29 Stanwell) 275kV line","Any one H24 Calvale - H29 Stanwell (855, 8873, 8874) + H58 Larcom Creek - H67 Calliope River (8859) 275kV line","Balranald to Buronga (X3) 220kV line","Balranald to Buronga (X3) and Balranald to Darlington Point (X5) 220kV lines","Balranald to Buronga (X3) and Buronga to Red Cliffs (X9) 220kV lines","Balranald to Darlington Point (X5) 220kV line","Balranald to Limondale 1 SF (X8) 220kV line","Bango 973 to Cowra(973)132kV line","Bango 999 WF to Cowra 132kV line (999)","Bango973 WF to Yass 132kV line(9GL)","Basslink Cable Load Prediction System (CLPS) dynamic rating data unavailable. Constraints to manage MW limits defined at receiving end.","Beryl to Crudine Ridge 132kV line (94M)","Bouldercombe to Calliope River (812) 275kV line","Burnie to Sheffield No.1 220kV line, West Coast 110 kV link between Farrell and Burnie open","Buronga 220kV CB7012","Central QLD outages","Crudine Ridge to MT Piper 132kV line (9ML)","DEFAULT","DEFAULT3","Dederang DBUSS-Line control scheme ","Dederang DBUSS-Transformer control scheme (System Normal and Prior Outage)","Dederang to Murray (DDTS - MSS) [67 or 68] 330kV line O/S, one line O/S only","Dederang to South Morang 330 kV line","Dederang to Wodonga 330kV line, 63 O/S","Dederang to Wodonga 330kV line, X5 O/S","Directlink - one Mullumbimby - Terranora DC cable O/S","Discretionary upper limit for SA WATER Morgan Whyalla Pump Station 3 PV generation of 0 MW","Discretionary upper limit for Summerfield 1 BESS of 0 MW","Discretionary upper limit for Tailem Bend 3 BESS of 0 MW","Discretionary upper limit for Torrens Island Battery of 0 MW","Discretionary upper limit on IBR within the NSW Buronga to Wagga area.","Discretionary upper limit on NSW to SA","Discretionary upper limit on SA to NSW","Discretionary upper limit on generators within North West Victoria (Bendigo-Ballarat-Red Cliffs area)","Discretionary upper limit on generators within South West Victoria (Moorabool to Heywood area)","Discretionary upper limit on generators within the Davenport to Robertstown area.","Discretionary upper limit on generators within the Elaine - Moorabool - Terang area.","Discretionary upper limit on generators within the Tungkillo to South East area.","Discretionary upper limits for Eraring BESS 2","Discretionary upper limits for Walla Walla solar farm 1 Generation","Discretionary upper limits on Bango 973 wind farm","Discretionary upper limits on Crudine Ridge wind farm","Discretionary upper limits on Finley solar farm","Discretionary upper limits on Gunnedah solar farm","Discretionary,Gladstone Unit 4 =< 0MW","Dry Creek 66kV CB G3","Dubbo132 to Wellington (94F or 94J ) 132 kV line","Dumaresq SVC","Eraring to Newcastle (90)","Feeder 813 or 814 between H67 Calliope River and H5 Woolooga","H10 Bouldercombe to H73 Raglan (811) 275kV line","H11 Nebo SVC","H12 Mt England - H36 Blackwall (802) 275kV line","H13 Ross 275 kV SVC O/S","H14 Middle Ridge to T147 Tangkam 732 110kV line O/S","H35 Strathmore SVC OOS","H36 Blackwall SVC O/S","H73 Raglan to H58 Larcom Creek (8875) 275kV line","Hazelwood to Rowville No.3 500kV line","Hazelwood to South Morang 500kV line","Kangaroo Valley to Capital (3W) line","Kemps Creek to Macarthur 330kV (37) line O/S","Kempsey 132kV bus #3","Kempsey 132kV bus section 1","Larcom Creek to Calliope River (8859) 275kV line","Liapootah to Chapel St 220kV line","Lismore SVC O/S","Load Event (APD)","Mt Gelibrand wind farm upper limit of 66 MW","Mt_Piper to Wellington (72) 330 kV line","Multiple NQLD outages","Multiple outage, both Bundey to Buronga (6C and 6F) and both Buronga to Dinawan (6G and 6H) 330kV lines","N-3 PEC Loop","NSW1 - to be used for zero MW for BESS for BDU Reliability directions","Nil","None","None. Zero facility dispatch","One 132 kV line between Ballina and Mullumbimby that opens the 132 kV path (9G2, 9G3, 9G4, 9G5 and Ballina 132/66kV Tx)","One 275kV Bus or one or more CB (89052,5812) at H13 Ross","One H20 Broadsound to H11 Nebo 275kV line (834 / 8846 / 8847) and one H11 Nebo to H35 Strathmore 275kV line (822 / 878 / 8845) O/S","One or more series 132kV feeder between H5 Woolooga and T70 Cooroy","One parallel 275kV fdr between H12 Mt England to H18 Tarong (837, 8812) + 802 (H36 Blackwall to H12 Mt England) 275kV fdr","Out = 5A5 (Wollar to Mt. Piper) 500kV line ","Out = 820 (H10 Bouldercombe to H20 Broadsound)  275kV line","Out = 821 275kV fdr H10 Bouldercombe - H11 Nebo,","Out = 834 (H20 Broadsound -H11 Nebo) 275kV feeder","Out = 842 Tarong  - Tarong Ps 275KV line.","Out = 843 Tarong  - Tarong PS 275KV line.","Out = 844 Tarong  - Tarong PS 275KV line.","Out = 848 or 849 H10 Bouldercombe to H29 Stanwell 275 kV line","Out = 8846 or 8847 (H20 Broadsound -H11 Nebo) 275kV line","Out = Ballarat to Elaine to Moorabool 220kV line and Moorabool to Ballarat No.1 line No.1 bus CB at Moorabool","Out = Balranald to Darlington Point (X5) 220kV line and Dapto - Kangaroo Valley (18) 330kV line","Out = Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Blyth West- Munno Para 275kV line and Munno Para-Para 275kV (i.e. with Blyth West CB8002 OPEN & Blyth West tripping scheme I/S) ","Out = Brinkworth - Davenport 275 kV line","Out = Bungama - Blyth West 275kV line O/S, (Blyth West trip scheme I/S)","Out = Canberra to Capital (6) 330kV line + one Dederang to South Morang (DDTS-SMTS) 330kV line O/S","Out = Carwarp to Red Cliffs 220kV line","Out = Dapto-Kangaroo Valley(18), [Note: Assumed Wagga-Yass OPEN (990 + 991 + 99P)]","Out = Darlington Point 330/132 kV Transformer #1 and #2","Out = Darlington Point to Yanco (99D) 132kV line.","Out = Georgetown to Sheffield 220kV line O/S, one line O/S only","Out = H11 Nebo SVC and H35 Strathmore SVC","Out = Hadspen to Palmerston (No.1 or No.2) 220kV line O/S, one line O/S only","Out = Heywood (HYTS) M1 or M2 500/275 kV txfmr","Out = Heywood to South East 275kV line  (Both Black Range series caps I/S)","Out = Keith - Kincraig 132 kV line  (Both Black Range series caps O/S)","Out = Lilyvale (H15) 275kV Bus no 1 or no2 and/or Lilyvale 275/132kV transformer 1 or 2 with 132kV network split between Baralaba and Moranbah , open fdrs 7114/1 at Baralaba end and 7382 and 7124/1 at Moranbah end","Out = Magill - Torrens Island 275 kV line","Out = Moorabool (MLTS) A2 500/220kV transformer O/S","Out = Morgan Whyalla Pipeline Pump No.3 - Robertstown 132kV line O/S, (Note: for Murraylink runback I/S or O/S).","Out = North West  Bend CBs 6023 and 6024 (Note:this offloads NWB-MWP1 132kV line),(Note: for Murraylink runback scheme I/S or O/S and Sever scheme I/S or O/S)","Out = North West Bend to Robertstown No.2 132kV line O/S,","Out = One H11 Nebo to H35 Strathmore 275KV line (822 / 878 / 8845)","Out = One South East-Tailem Bend 275kV line (One Black Range series cap I/S)","Out = Para - Templers West 275kV line","Out = South Morang 500/330kV F1 or F2 transformer, radial mode","Out = Torrens Island-New Osborne #3 66kV line (WITH/WITHOUT associated line CB I/S)","Out = both Buronga Syncon 4 & 5 (two syncons)","Out = either one of Black Range series capacitors bypassed,","Out = one 275kV Bus or one or more 275kV CB (8522, 8712) at Calvale (H24)","Out = one 275kV Bus or one or more 275kV CB (88732,CB 88312,CB8492, CB8612, CB88742, CB8622, CB8632, CB8642, CB8562, CB8552) at Stanwell (H29)","Out = one 275kV Bus or one or more CB (CB8202, CB8342, CB88472, CB88312, CB8562, CB8332) at Broadsound (H20) ","Out = one 275kV Bus or one or more CB(8792,88452,88572,8782) at Strathmore (H35)","Out = one 275kV bus or one or more CB (8342,8222) at H11 Nebo","Out = one of the Columboola 275/132 kV transformers(TX2 or TX3)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series capacitors I/S)","Out=  Angas Creek-Para 132kV line O/S; (Both Black Range series caps O/S)","Out= 7243 Mt Stuart Power Station Townsville South 132kV line","Out= 7246 Oakey Tangkam 132kV line","Out= 7247 Oakey Tangkam 132kV line","Out= 966 (Armidale to Koolkhan) 132kV line [NOTE: Open at Koolkan end ONLY, Armidale end remains closed]  O/S and Coffs Harbour CB 892A opened - Arrangement 1 - see OM521","Out= 966 (Armidale to Koolkhan) 132kV line[NOTE: Open at Koolkan end ONLY, Armidale end remains closed] O/S - Arrangement 2 - see OM521","Out= 968 (Tamworth to Narrabri) and 96M (Narrabri to Moree) 132kV line","Out= 968 (Tamworth to Narrabri) and 96M(Narrabri to Moree) 132kV line","Out= 96M (Moree to Narrabri) 132kV line","Out= Angas Creek-Mannum 132kV line (Both Black Range series capacitors I/S); (Note:This offloads Mannum-Adelaide Pumping Station PVs 2 & 3)","Out= Any one 132kV feeder between Narrabri to Gunnedah Solar Farm (9UH, 9UJ, 9U3/2)","Out= Any one 275kV feeders between S2 Halys to H18 Tarong (8868,8869,8870,8871)","Out= Any two 275kV feeders between S2 Halys to H18 Tarong (8868,8869,8870,8871)","Out= Blyth West- Munno Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Blyth West- Munno Para 275kV line and Munno Para-Para 275kV line (i.e. with Blyth West CB8002 CLOSED or Blyth West trip scheme O/S)","Out= Brinkworth 132kV CB6071 Or Brinkworth 132kV East bus O/S","Out= Brinkworth 275/132kV TX3 transformer (with/without associated CBs 6530 & 6528& 6093 & 6068 OPEN).","Out= Bungama 275kV CB6538 OR CB6539 (NOTE: Only one CB O/S at a given time)","Out= Buronga to Red Cliffs (X1) 220kV line","Out= Buronga to Red Cliffs (X9) 220kV line","Out= Cherry Gardens - Mt Barker South 275kV line","Out= Dapto - Kangaroo Valley (18) [Note: Wagga-Yass 132kV parallel lines CLOSED]]","Out= Dederang H1 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Dederang H2 330/220kV transformer. Prior outage DBUSS-T scheme disabled","Out= Either one of  South East CB 6611 Or 6605 Or 6610 Or 6604 O/S (Both Black Range series caps I/S)","Out= Either one of  South East CB 6611 Or 6605 Or 6610 Or 6604 O/S (Both Black Range series caps O/S)","Out= Either one of  South East SVC O/S (Both Black Range series caps I/S)","Out= Either one of  South East SVC O/S (Both Black Range series caps O/S)","Out= Glenrowan to Pine Lodge 220kV line","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3)); (Both Black Range series capacitors O/S)","Out= Mannum-Mannum Adelaide Pump 2 132kV line(Note: Assumed  Mannum Adelaide 2 SF remains I/S and connected via MA3); (Both Black Range series capacitors I/S)","Out= Molong to Orange North (94T) 132kV line and Beryl to Crudine Ridge 132kV line (94M)","Out= Morgan Whyalla Pump 2 - Morgan Whyalla Pump 3 132 kV line","Out= Mt Barker South-Tungkillo 275kV line (Both Black Range series caps I/S)","Out= One Davenport 275/132kV TX O/S -- Refer to Electranet's OI E5.19","Out= One Para SVC (Note: With both black range series caps O/S)","Out= One of Coffs Harbour to Kempsey (9W5 or 9W6 or 9W7 or 9W8), Note: Auto detect PST status included","Out= Para 275kV CB6509 ","Out= Stubbo to Uungula (79) 330kV line","Out= Tailem Bend 275kV CB6536 O/S Only (Note: Other 275 kV CBs, all lines or Transformer at Tailem Bend are I/S)","Out= Tarrone 500kV bus CB (one CB only)","Out= Torrens Island to Cherry Gardens 275kV line","Out= Torrens Island to Torrens North #1 66kV line","Out= Uungula to Wellington (7J) 330kV line","Out= Wellington to Molong (945) 132kV line","Out= Yanco to Narrandera (9HT) 132kV line;  X5 Trip Scheme Disarmed, 132 kV parallel Solid, option c OM521","Out= one Darlington Pt 132/330kV TX1 or TX2, OM524","Out=968 (Tamworth to Narrabri) 132 kV Line ","Out=Farrell-Tribute 220KV line","Out=Tailem Bend 132kV CB 6123 O/S Only","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, 63 Open, 9R4 Open, and with 2 Yass TXs in service","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 Open, 9R4 Open, and with 2 Yass TXs in service","Outage = Jindera- Walla Walla (62), Wagga-Yass 132kV split, X5 and 63 Open, 9R4 Open, and with 2 Yass TXs in service","Para SVC O/S, one SVC only","Prior outage of Avon to Dapto (10) 330kV line","Prior outage of Canberra to Capital (6) line","Prior outage of Dapto to Marulan (8) 330kV line","Prior outage of Dapto to Sydney South (11) 330kV line","Prior outage of Darlington Point to Wagga (63) 330kV line and 99J,99D,99L,9R4 132kV lines opened","Prior outage of Eraring to Vineyard (25) 330kV line","Prior outage of Stockdill to Upper Tumut (1) 330kV line","Prior outage of one Darlington Point 330/220/33 kV tie Tx (#3 or #4)","QLD1 - to be used for zero MW for BESS for BDU Reliability directions","R2 Braemar to H48 Braemar 2 PS 275kV line 8840","Rangebank BESS BDU Zero energy and FCAS","Rowville to South Morang 500kV line","SA1 - to be used for zero MW for BESS for BDU Reliability directions","Salt Creek wind farm upper limit of 0 MW","Springlands (TX1) 132/33kV transformer","Springlands (TX2) 132/33kV transformer","Sydney West to Vineyard (29) line","Tamworth No.1 330kV Bus O/S","Tamworth SVC","Tamworth to Gunnedah (969) 132kV line","Templers BESS BDU zero energy and FCAS","Terang BESS BDU zero Energy and FCAS","Thomastown to Templestowe 220 kV line","Torrens B unit 2 Transformer","Two Ross 275/132 kV transformer","Two non-parallel (8905 || (8916||8917 + 858||858 + 876||877|8902||8932)), three non-parallel (848||849 + 812||(811+8875+8859)||855||8873||8874 + 820||821 + 821||834||8846||8847 + 822||878||8845 + (879+8911)||8857||8858) + Ross SVC","VIC1 - to be used for zero MW for BESS for BDU Reliability directions","Wagga 330kV bus A. (Note: Wagga-Yass 132kV network split, X5 opened, with 2 Yass Transformer in service, Wagga-Darlington Pt open via 63 or 9R3+9HR+9HT)","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, 63 + 9R4 + 996 open","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, Darlington Point-Wagga 132kV split, X5 + 63 + 9R4 + 996 open","Wagga to Walla Walla (6Y) 330kV line, Wagga-Yass 132kV split, X5 + 9R4 + 996 open","Wyalong Solar Farm upper limit of 0 MW","^ Multiple Outage, 6C, 6G, 6H 330kV lines","one of Mt Piper 500/330kV tie Tx."]},"SYSTEMNORMAL":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Not used as of 2005 End of Year Release [was Flag to indicate if the constraint set is a system normal (1) or and an outage set (0)]","examples":["0"],"unused":true,"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENCONSETTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":27770,"decompressed_size_all_time":34735710},"visibility":"Public","trigger":"Ad hoc"},"GENERICCONSTRAINTRHS":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GCRHS","REPORT_SUB_TYPE":"NULL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#45"],"comment":"GENERICCONSTRAINTRHS sets out details of generic constraint Right Hand Side (RHS) formulations for dispatch (DS), predispatch (PD) and Short Term PASA (ST). GENERICCONSTRAINTRHS also includes general expressions (EQ) used in the dispatch, predispatch and PASA time frames.\nGENERICCONSTRAINTRHS replaces data previously available via the \"Constraint Library” Excel spreadsheet.","description":"GENERICCONSTRAINTRHS is public data, and is available to all\nparticipants.\n\nSource\n\nGENERICCONSTRAINTRHS updates whenever a new generic constraint RHS or\nexpression is created or modified\n\nVolume\n\nApproximately 70,000 records per year\n\nNote\n\nGENERICEQUATIONRHS and GENERICEQUATIONDESC allow commonly used\nconstraint right hand side formulations to be defined as a generic\nequation. Once defined, the generic equation can be referenced from any\nGeneric constraint RHS formulation defined in GENERICCONSTRAINTRHS.","primary_keys":["EFFECTIVEDATE","GENCONID","SCOPE","TERMID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Constraint Identifier","examples":["#R036713_001_RAMP_F","#R036713_001_RAMP_V","#R036714_001_RAMP_F","#R036714_001_RAMP_V","#R036715_001_RAMP_F","#R036715_001_RAMP_V","#R036715_002_RAMP_F","#R036715_002_RAMP_V","#R036715_003_RAMP_F","#R036715_003_RAMP_V","#R036716_001_RAMP_F","#R036716_001_RAMP_V","CA_SYDS_59A889E5_1"]},"SCOPE":{"sql_type":"VARCHAR2(2)","pl_type":"str","mandatory":true,"comment":"Scope of RHS term (DS, PD, ST or EQ)","examples":["DS","PD","ST"]},"TERMID":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The unique identifier for the a constraint RHS term","examples":["1","145"],"is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"DEFAULTVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Default value if primary source given by SPD_ID and SPD_TYPE not available.","examples":["-26.5845","57.4706","0","100000"],"is_float":true},"FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Multiplier applied to operator result","examples":["-0.0051","0.008","0","6"],"is_float":true},"GROUPID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"ID of super-term, if this is a sub-term","examples":["3"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Unitary operator to apply to data value","examples":["ADD","DIV","MAX","MIN","MUL","PUSH","SUB"]},"PARAMETERTERM1":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the first term (logic expression) to use in a Branch term"},"PARAMETERTERM2":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the second term (logic<=0 result) to use in a Branch term"},"PARAMETERTERM3":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the third term (logic>0 result) to use in a Branch term"},"SPD_ID":{"sql_type":"VARCHAR2(21)","pl_type":"str","mandatory":false,"comment":"ID defining data source","examples":["#R036713_001_RAMP_XE","#R036713_001_RAMP_XI","#R036713_RAMP_DI_LEFT","#R036714_001_RAMP_XE","#R036714_001_RAMP_XI","#R036714_RAMP_DI_LEFT","#R036715_001_RAMP_XE","#R036715_001_RAMP_XI","#R036715_002_RAMP_XE","#R036715_002_RAMP_XI","#R036715_003_RAMP_XE","#R036715_003_RAMP_XI","#R036715_RAMP_DI_LEFT","#R036716_001_RAMP_XE","#R036716_001_RAMP_XI","#R036716_RAMP_DI_LEFT","AGLHAL.SHPS1","AGLSOM.VTTS1","ALDGASF1.QLCS1A","ANGAST1.SDRN1","ARWF1.VART1A","AVLSF1.NNRN1A","BALB1.VBA23B","BALDHWF1.VMWT9B","BANN1.VWES1B","BARCALDN.QBCG","BARRON-1.QBGH1","BARRON-2.QBGH2","BBATTERY1.QBCB3B","BDL01.VMWT2","BDL02.VMWT3","BHB1.NBKB3B","BLOWERNG.NBLW8","BLUEGSF1.QCBS1B","BLUFF1.SBEL2P","BLYTHB1.SBYW1B","BNGSF1.SBEM1B","BNGSF2.SBEM2B","BOMENSF1.NWGS1B","BRAEMAR1.QBRA1","BRAEMAR2.QBRA2","BRAEMAR3.QBRA3","BRAEMAR5.QBRA5B","BRAEMAR6.QBRA6B","BRAEMAR7.QBRA7B","BRDDBES1.QBSS2B","BRDDSF01.QBSS1B","BROKENH1.NBK11B","BRYB1WF1.VBBT1B","BRYB2WF2.VBBT2B","BULBES1.VBGT4B","BULGANA1.VBGT1B","BUNGAMB1.SBUA1B","CALL_B_1.QCAB1","CALL_B_2.QCAB2","CATHROCK.SCRK","CGBESS01.SCGB1C","CHBESS1.QWDB3C","CHILDSF1.QTBS1C","CHYTWF1.VSM71C","CLARESF1.QCLA1C","CLEMGPWF.SCGW1P","CLERMSF1.QLLV3C","CLRKCWF1.QBSW1C","CLRKCWF2.QBSW2C","CNUNDAWF.SSNN1","COHUNSF1.VKGS2C","COLEASF1.NCLS1C","COLUMSF1.QCBR1C","COOPGWF1.QCPG1C","CPP_3.QCAC3","CPP_4.QCAC4","CPSA.QCND1C","CROWLWF1.VCWL1C","CRWASF1.NAL11C","CSPVPS1.QCOS1C","DALNTH1.SDAN3D","DARLSF1.NDNS1D","DARTM1.VDPS","DAYDSF1.QCCK1D","DDPS1.QBRA8D","DDSF1.QBRS1D","DELTA_XEND_XINIT","DI_LEFT_MUL_XINIT","DI_LEFT_SOFT_ADJ","DI_SOFT_ADJ","DI_TOTAL","DI_TOTAL_SOFT_ADJ","DPNTB1.NRDP3D","DULAWF1.QCBF1D","DUNDWF1.VM051D","DUNDWF2.VM052D","DUNDWF3.VM053D","EDENVSF1.QORS1E","EILDON1.VEPS1","EILDON2.VEPS2","EMERASF1.QLIS1E","FINAL_RHS","FINLYSF1.NFNS1F","GANGARR1.QWSS1G","GANNB1.VKGB3G","GANNSF1.VKGS1G","GIRGSF.VSHS2G","GLENSF1.VGN21G","GLRWNSF1.VGNS1G","GOESF1.VGET1G","GREENB1.QGBB1G","GSTONE1.QGLD1","GSTONE2.QGLD2","GSTONE3.QGLD3","GSTONE4.QGLD4","GSTONE5.QGLD5","GSTONE6.QGLD6","GSWF1A.SROB1G","GSWF1B1.SRAB1G","GUSF1.QBLG1G","HALLWF1.SHPS2W","HALLWF2.SMOK1H","HAMISF1.QSLD1H","HAUGHT11.QHAR1H","HAYMSF1.QCCK2H","HBESS1.VHW23H","HD1WF1.VTR11H","HDWF1.SHDW1H","HDWF2.SHDW2H","HDWF3.SHDW3H","HILLSTN1.NDNH1H","HPR1.SMTL3H","HUMEV.VHUM","JLA01.VJLGA1","JLA02.VJLGA2","JLA03.VJLGA3","JLA04.VJLGA4","JLB01.VJLGB1","JLB02.VJLGB2","JLB03.VJLGB3","JUNEESF1.NWGJ1J","KABANWF1.QTMW1K","KAREEYA1.QKAH1","KAREEYA2.QKAH2","KAREEYA3.QKAH3","KAREEYA4.QKAH4","KARSF1.VRCS1K","KEPSF1.QROW2K","KEPWF1.QROW1K","KERNGSP1.VKGP1K","KESSB1.VKOT1K","KIAMSF1.VKMT1K","KIATAWF1.VHOG1K","KINGASF1.QTRS1K","KPP_1.QBRA4K","KSP1.QROG1K","LADBROK1.SPEW1","LADBROK2.SPEW2","LBB1.SLBB3L","LGAPBS1.SLGW5L","LGAPWF1.SLGW1L","LGAPWF2.SLGW4L","LHS_GROUP","LILYSF1.QBDR1L","LIMBESS1.NLMB1L","LIMOSF11.NBSF1L","LIMOSF21.NBL21L","LKBONNY1.SMAY1","LKBONNY2.SMAY2","LKBONNY3.SMAY3W","LOYYB1.VLYP5","LOYYB2.VLYP6","LVES1.VMW61L","LYA1.VLYP1","LYA2.VLYP2","LYA3.VLYP3","LYA4.VLYP4","MACARTH1.VTRT1M","MANNSF2.SMAE1M","MANNUMB1.SMAB1M","MAPS2PV1.SMA21M","MAPS3PV1.SMA31M","MARYRSF1.QMRY2M","MAX_AT_ZERO","MBPS2PV1.SMH21M","MCINTYR1.QMSW1M","MCKAY1.VMKP1","MERCER01.VELT1M","MEWF1.QWKM1M","MIDDLSF1.QLIS2M","MINTARO.SMPS","MIN_XINIT_AND_LHS","MOKOSF1.VGN61M","MORTLK11.VM0P1O","MORTLK12.VM0P2O","MOUSF1.QMRR1M","MPP_1.QBCK1","MPP_2.QBCK2","MREHA1.VPRT1M","MREHA2.VPR21M","MREHA3.VPR31M","MRNBESS1.VTB21M","MRTLSWF1.VTG21M","MSTUART1.QMSP1","MSTUART2.QMSP2","MSTUART3.QMSP3M","MTGELWF1.VGTW1M","MTMILLAR.SMTM1","MUCRKSF1.QWLM1M","MULWASF1.NAL12M","MURRAY.NMUR8","MUWAWF1.VMRT1M","MUWAWF2.VMRT2M","MVA_BA_ML2","MVA_TG_ML","MWPS1PV1.SMW11M","MWPS2PV1.SMW21M","MWPS3PV1.SMW31M","MWPS4PV1.SMW41M","Margin","N-Q-MNSP1","NBHWF1.SBEL1A","NPS.VNPS","NSW1-QLD1","NUMURSF1.VSHS1N","OAKEY1.QOKY1","OAKEY1SF.QTKS1O","OAKEY2.QOKY2","OAKEY2SF.QTKS2O","OAKLAND1.VTGT3A","PAREPS1.SDAP2P","PAREPW1.SDAP1P","PD_Const","PIBESS1.VMWT12","POR01.SPLN1","POR03.SPL31P","RAMP_INCREMENT","RANGEB1.VCB33R","RAW_RAMP_INCREMENT","RESS1.NRBB3R","RIVNB2.NRB23R","ROMA_7.QRMA7","ROMA_8.QRMA8","RRSF1.QROG3R","RUGBYR1.QMPL1R","RYANCWF1.VTR31R","SALTCRK1.VTG61S","SEBSF1.NWGJ2S","SMCSF1.QTZS1S","SNOWNTH1.SBLWS1","SNOWSTH1.SBLWS2","SNOWTWN1.SNWF1T","SNUG1.SSGA1","SOL_V_WNSF","SRSF1.QTBS2S","STABESS1.QSTB1S","STAN-1.QSTN1","STAN-2.QSTN2","STAN-3.QSTN3","STAN-4.QSTN4","STOCKYD1.VHGT1S","STWF1.NBKW1S","SUNRSF1.NBSF2S","SWANBBF1.QBKB1S","SWAN_E.QSWE","Scaleup","T-V-MNSP1","TARBESS1.QTRB1T","TARONG#1.QTRN1","TARONG#2.QTRN2","TARONG#3.QTRN3","TARONG#4.QTRN4","TB2B1.STBB4T","TB2SF1.STBB1T","TBSF1.STBS1T","TEMPB1.STET1T","TNPS1.QTNT","ULPBESS1.QWDS1U","URANQ11.NURQ1U","URANQ12.NURQ2U","URANQ13.NURQ3U","URANQ14.NURQ4U","V-S-MNSP1","V-SA","VBB1.VMLB3V","VIC1","VIC1-NSW1","VPGS1.VLYP07","VPGS2.VLYP08","VPGS3.VLYP09","VPGS4.VLYP010","VPGS5.VLYP011","VPGS6.VLYP012","VRAT15_BAML2","W/HOE#1.QWIV1","W/HOE#2.QWIV2","WAGGNSF1.NWGG1W","WAMBOWF1.QDMW1W","WAMBOWF2.QDMR1W","WANDB1.QWSB3W","WANDSF1.QWSR1W","WANDSF2.QWSR2W","WARWSF1.QMRY3W","WARWSF2.QMRY4W","WATERLWF.SWLE","WDBESS1.QWDE3W","WDBESS2.QWDE4W","WDGPH1.QWDR1W","WEMENSF1.VWES2W","WGWF1.SWGL1W","WHITSF1.QSLS1W","WIND_V_CHL","WIND_V_MTN","WIND_V_P3C","WIND_V_WBR","WIND_V_YBK","WIND_V_YLK","WINTSF1.VGNS2W","WKIEWA1.VWKP1","WOOLES1.QWLB1W","WOOLGSF1.QWLS1W","WPWF.SSYP1","WSTWYSF1.NWGJ3W","WUNUSF1.VSHS2W","WYASF1.NWGJ4W","YABULU.QTYP","YABULU2.QGAR1","YARANSF1.QMRY1Y","YATSF1.VRCS2Y","YENDWF1.VBAW1Y","YWPS1.VYP21","YWPS2.VYP22","YWPS3.VYP23","YWPS4.VYP24","ZERO_CONSTANT"]},"SPD_TYPE":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID describing type of data source","examples":["A","C","E","G","I","R","T","U"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENERICCONSTRAINTRHS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1949112,"decompressed_size_all_time":2151908170},"visibility":"Public","trigger":"When a new generic constraint RHS or expression is created or modified"},"GENERICEQUATIONDESC":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GEQDESC","REPORT_SUB_TYPE":"NULL","VERSION":1},{"REPORT_NAME":"GEQDESC","REPORT_SUB_TYPE":"NULL","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#54"],"comment":"GENERICEQUATIONDESC defines a generic equation identifier with a description. The formulation of the generic equation is detailed in GENERICEQUATIONRHS.","description":"GENERICEQUATIONDESC data is public to all participants.\n\nSource\n\nGENERICEQUATIONDESC updates when new a generic equation is created for\nthe first time.\n\nVolume\n\nApproximately 100 records per year\n\nNote\n\nGENERICEQUATIONRHS and GENERICEQUATIONDESC allow commonly used\nconstraint right hand side formulations to be defined as a generic\nequation. Once defined, the generic equation can be referenced from any\nGeneric constraint RHS formulation defined in GENERICCONSTRAINTRHS.","primary_keys":["EQUATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"EQUATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Equation Identifier","examples":["SWMP_IF_GFT2_IS","SWMP_IF_GFT2_OS","SWMP_IF_KM_CB_IS","SWMP_IF_KM_CB_OS","X-7C2K0H350(2G)_DS","X-7C2K0H350(2G)_PD","X-7C2K0H350(2G)_ST","X-7C2K350(2G)_DS","X-7C2K350(2G)_PD","X-7C2K350(2G)_ST","X-7C2K350N_DS","X-7C2K350N_PD","X-7C2K350N_ST","X-7C2K350_DS","X-7C2K350_PD","X-7C2K350_ST","X-7C2K50(2G)_DS","X-7C2K50(2G)_PD","X-7C2K50(2G)_ST","X-7C2KH350(2G)_DS","X-7C2KH350(2G)_PD","X-7C2KH350(2G)_ST","X-7C2KH350_DS","X-7C2KH350_PD","X-7C2KH350_ST","X-7C2KH50(2G)_DS","X-7C2KH50(2G)_PD","X-7C2KH50(2G)_ST","X-7CH350(2G)_DS","X-7CH350(2G)_PD","X-7CH350(2G)_ST","X-7CH50(2G)_DS","X-7CH50(2G)_PD","X-7CH50(2G)_ST","X-7CT350(2G)_DS","X-7CT350(2G)_PD","X-7CT350(2G)_ST","X-7CT50(2G)_DS","X-7CT50(2G)_PD","X-7CT50(2G)_ST","X-A17_SF_DS","X-A17_SF_PD","X-A17_SF_ST","X-A17_WF_DS","X-A17_WF_PD","X-A17_WF_ST","X-CHK_1_TV_PD","X-LOOP_SRES_MW","X-LOOP_VRES_MW","X-NQ_WAMPAC","X-NQ_WAMPAC_PD","X_N^^N_LTWG_PEC2_DS","X_N^^N_LTWG_PEC2_PD","X_N^^N_WGLT_DS","X_N^^N_WGLT_PD","X_N^^N_WGLT_PEC2_DS","X_N^^N_WGLT_PEC2_PD","X_N^^N_WGLT_PEC2_ST","X_N^^N_WGLT_ST"]},"ADDITIONALNOTES":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Extra notes on the constraint","examples":["A17.b and A17.c ver 30","A17.b row 1 Rev30; A38.d row 3 Rev31; A39 row 3 Rev31","A17.b row 3 Ver 30","A17.c row 1 Rev30; A38.d row 4 Rev31; A39 Row 4 Rev31","A17.c row 3 Rev30; A38.d row 8 Rev31; A39 row 8 Rev31","A38.d Row 5 Rev31, A39 Row 5 Rev31","A38.d Row 5 Rev31, A39 Row 5 Rev31; Assume Haughton Syncon ON","A38.d Row 6 Rev31, A39 Row 6 Rev31","A38.d Row 6 Rev31, A39 Row 6 Rev31; Assume Haughton Syncon ON","A39b Row 2 Rev31","A39b Row 2 Rev31; Assume Haughton Syncon ON","A5 row 2, ver 30","A50 row 1, ver 30","A50 row 3, ver30","Assume Haughton Syncon ON","CCR10206 FNQ System Strength WAMPAC Scheme - Operation Guide v1.1","CCR10271","Nil","OM520, CCR10250","OM520, CCR10270","Powerlink NQLD System Strength v17"]},"DESCRIPTION":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Generic Equation Description","examples":["Check Townsville GT Unit 1 available; If true return 1 else 0 (PREDISPATCH ONLY)","Check if Generator Fast Tripping (GFT) is out of service and swamp out if not in service","Check if Kiamal is connected and swamp out if in service","Limit calc for Lower Tumut to Wagga (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51 - Dispatch","Limit calc for Lower Tumut to Wagga (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51 - PreDispatch","Limit calc for Wagga to Lower Tumut (051) 330kV line flow to avoid voltage collapse post contingency trip of line 051 - Dispatch","Limit calc for Wagga to Lower Tumut (051) 330kV line flow to avoid voltage collapse post contingency trip of line 051 - Predispatch","Limit calc for Wagga to Lower Tumut (051) 330kV line flow to avoid voltage collapse post contingency trip of line 051 - ST PASA","Limit calc for Wagga to Lower Tumut (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51 - Dispatch","Limit calc for Wagga to Lower Tumut (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51 - PreDispatch","Limit calc for Wagga to Lower Tumut (51) 330kV line flow to avoid voltage collapse post contingency trip of line 51 - ST PASA","Residual SA non-forecasted load MW with matching high RHS gen factors","Residual VIC non-forecasted load MW with matching high RHS gen factors","if >=2 Stanwell, >=1 Callide B, >=4 Gladstone, >=2 Kareeya, >=350 NQ Demand, >=150 Ross+FNQ demand, NQ WAMPAC X and/or Y control protection status; return 1 else 0; NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Glad, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Glad, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Glad, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE:PRE DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Haughton Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 150;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >= 2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=1 Townsville GT/Syncon, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand and Night check is true: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand and Night check is true: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand and Night check is true: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon ON, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya,Haughton syncon IS, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Callide+Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya,Haughton syncon IS, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton ON, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon OFF, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon OFF, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PASA ","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon OFF, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon ON, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton Syncon ON, >=50 NQ demand, >=0 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton syncon ON, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, >=2 Kareeya, Haughton syncon ON, >=350 NQ demand, >=150 Ross+FNQ demand: return 1 else 0;   NOTE: PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit Solar farms to 40%,30%,20%  or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0. DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit Solar farms to 40%,30%,20%  or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0. PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit Solar farms to 40%,30%,20%  or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0.PREDISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit windfarms to 25% or 15% or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0. DISPATCH","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit windfarms to 25% or 15% or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0. PASA","if >=2 Stanwell, >=3 Stanwell+Callide, >=2 Gladstone, >=7 Stanwell+Callide+Gladstone, limit windfarms to 25% or 15% or 1% depending on NQLD and Ross_FNQ demand and Haughton syncon or Townsville GT status, otherwise 0. PREDISPATCH","if NQ WAMPAC X and/or Y control protection status; return 1 else 0; NOTE: PREDISPATCH"]},"IMPACT":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"The device(s) affected by the constraint (e.g. Interconnector, Generator(s) or Cutset)","examples":["NSW Generation + Interconnectors","Other","Qld Generation"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 14:56:19"],"parse_csv_as_string":true,"is_s_datetime":true},"LIMITTYPE":{"sql_type":"VARCHAR2(64)","pl_type":"pl.Categorical","mandatory":false,"comment":"The limit type of the constraint e.g. Transient Stability, Voltage Stability","examples":["Other","System Strength","Voltage Stability"]},"MODIFICATIONS":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"Details of the changes made to this version of the generic equation RHS","examples":["Fix Limondale BESS","New","New limit for commissioning of PEC2","New, CCR10205","New, CCR10207","New, CCR10216","New, CCR10237","Updated for PEC stage 2 commissioning - tune PD/ST and fix Limondale BESS","Updated for PEC stage 2 commissioning and fix Limondale BESS","updated to include Townsville GT Syncon Status; CCR10257"]},"REASON":{"sql_type":"VARCHAR2(256)","pl_type":"str","mandatory":false,"comment":"The contingency or reason for the constraint","examples":["Check calc for Townsville GT Unit 1 online (PREDISPATCH)","Check status of NQ WAMPAC","Check status of Stanwell, Callide B, Gladstone, Kareeya, NQ demand, Ross+FNQ demand, NQ WAMPAC","Check status of Stanwell, Callide, Gladstone, Haughton Syncon, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, Kareeya, Haughton Syncon, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, Kareeya, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, Kareeya, NQ demand, Ross+FNQ demand,Haughton Syncon","Check status of Stanwell, Callide, Gladstone, Kareeya, NQ demand, Ross+FNQ demand,Haughton syncon","Check status of Stanwell, Callide, Gladstone, Kareeya,Townsville GT, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, Townsville GT, NQ demand, Ross+FNQ demand","Check status of Stanwell, Callide, Gladstone, Townsville GT/Syncon, NQ demand, Ross+FNQ demand","Fault on Lower Tumut to Wagga (051) 330kV line","Fault on Lower Tumut to Wagga (51) 330kV line","GFT status check","Kiamal CB status check","Loop RHS calc"]},"SOURCE":{"sql_type":"VARCHAR2(128)","pl_type":"str","mandatory":false,"comment":"The source of the constraint formulation","examples":["AEMO","Powerlink","Transgrid"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENERICEQUATIONDESC%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":2303,"decompressed_size_all_time":1643240},"visibility":"Public","trigger":"When new a generic equation is created"},"GENERICEQUATIONRHS":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GEQRHS","REPORT_SUB_TYPE":"NULL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#63"],"comment":"GENERICEQUATIONRHS stores the formulation of commonly used Generic Constraint Right Hand Side Equations referenced from Generic Constraint Right Hand Side definitions stored in GENERICCONSTRAINTRHS. The Generic Equation definitions are versioned and the latest effective version is applied to the dispatch process.","description":"GENERICEQUATIONRHS data is public to all participants.\n\nSource\n\nGENERICEQUATIONRHS updates whenever a generic equation is created or\nmodified.\n\nVolume\n\nApproximately 1,000 records per year\n\nNote\n\nGENERICEQUATIONRHS and GENERICEQUATIONDESC allow commonly used\nconstraint right hand side formulations to be defined as a generic\nequation. Once defined, the generic equation can be referenced from any\nGeneric constraint RHS formulation defined in GENERICCONSTRAINTRHS.\n\nTo reference a generic equation from a generic constraint RHS\ndefinition, specify a SPD_TYPE of ‘X’ and the SPD_ID equivalent to the\nEQUATIONID field in GENERICEQUATIONRHS.","primary_keys":["EFFECTIVEDATE","EQUATIONID","TERMID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"EQUATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Equation Identifier","examples":["X-7C2K350N_DS","X-7C2K350N_PD","X-7C2K350N_ST","X-7C2K350_DS","X-7C2K350_PD","X-7C2K350_ST","X-7C2KH350_DS","X-7C2KH350_PD","X-7C2KH350_ST","X-7CH50(2G)_DS","X-7CH50(2G)_PD","X-7CH50(2G)_ST","X-A17_SF_DS"]},"TERMID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The unique identifier for the a equation RHS term","examples":["1","136"],"is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEFAULTVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Default value if primary source given by SPD_ID and SPD_TYPE not available.","examples":["0","-1","1","600"],"is_float":true},"FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Multiplier applied to operator result","examples":["0.01","0","-1","-370"],"is_float":true},"GROUPID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"ID of super-term, if this is a sub-term","examples":["1","109"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 14:56:19"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Unitary operator to apply to data value","examples":["MAX","MUL","PUSH","STEP"]},"PARAMETERTERM1":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the first term (logic expression) to use in a Branch term"},"PARAMETERTERM2":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the second term (logic<=0 result) to use in a Branch term"},"PARAMETERTERM3":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":false,"comment":"The unique identifier for the third term (logic>0 result) to use in a Branch term"},"SPD_ID":{"sql_type":"VARCHAR2(21)","pl_type":"str","mandatory":false,"comment":"ID defining data source","examples":["250H","250_TV","350H","350_TV","50_H_TV","7C","CALL+GLAD_>=2","CALL_B1_ONSTATUS","CALL_B2_ONSTATUS","CALL_B_1.QCAB1","CALL_B_2.QCAB2","CHECK_CONSTANT","CHK_BOTH_CONDITIONS","CHK_IRAD_H","CHK_TVLLE_ON","CLARESF1.QCLA1C","CPP_3.QCAC3","CPP_3_ONSTATUS","CPP_4.QCAC4","CPP_4_ONSTATUS","CSF_IRAD_H","DAYDSF1.QCCK1D","DS_ERROR","Error_Scale_Factor","GLAD_>=2","GSTONE1.QGLD1","GSTONE1_ONSTATUS","GSTONE2.QGLD2","GSTONE2_ONSTATUS","GSTONE3.QGLD3","GSTONE3_ONSTATUS","GSTONE4.QGLD4","GSTONE4_ONSTATUS","GSTONE5.QGLD5","GSTONE5_ONSTATUS","GSTONE6.QGLD6","GSTONE6_ONSTATUS","HAUGHT11.QHAR1H","HAUGHTON_SYNCON_ON","HUSF_IRAD_H","KAREEYA1.QKAH1","KAREEYA1_ON","KAREEYA2.QKAH2","KAREEYA2_ON","KAREEYA3.QKAH3","KAREEYA3_ON","KAREEYA4.QKAH4","KAREEYA4_ON","KAREEYA_>=2","KSP1.QROG1K","NO_HUSF_INV","NO_IRAD_H","NO_SMSF_INV","NQ_LOAD>=250","NQ_LOAD>=350","NQ_LOAD>=370","NQ_LOAD>=50","NQ_LOAD>=70","NQ_LOAD_A>=270","NQ_LOAD_A>=370","NQ_LOAD_A>=70","Neg_PD_STATUS","PD_STATUS","PERIOD_ID","PERIOD_ID_01","PERIOD_ID_02","PERIOD_ID_03","PERIOD_ID_04","PERIOD_ID_05","PERIOD_ID_06","PERIOD_ID_07","PERIOD_ID_08","PERIOD_ID_09","PERIOD_ID_10","PERIOD_ID_11","PERIOD_ID_12","PERIOD_ID_13","PERIOD_ID_14","PERIOD_ID_15","PERIOD_ID_16","PERIOD_ID_17","PERIOD_ID_18","PERIOD_ID_19","PERIOD_ID_20","Periods_Scal_Factor","QKAH1_ONSTATUS","QKAH1_SYNCON_ON","QKAH2_ONSTATUS","QKAH2_SYNCON_ON","QKAH3_ONSTATUS","QKAH3_SYNCON_ON","QKAH4_ONSTATUS","QKAH4_SYNCON_ON","Q_DEMAND_NTH","Q_FARNORTH","Q_NQ_LOAD_AVER","Q_NTH","Q_ROSS","Q_ROSS_FN_LOAD_AVER","ROSS+FN_LOAD>=0","ROSS+FN_LOAD>=100","ROSS+FN_LOAD>=150","ROSS+FN_LOAD>=170","ROSS+FN_LOAD>=20","ROSS+FN_LOAD_A>=120","ROSS+FN_LOAD_A>=170","ROSS+FN_LOAD_A>=20","ROSS_FN_LOAD","RRSF1.QROG3R","RRSF_IRAD_H","SMCSF1.QTZS1S","SMSF_IRAD_H","SOLAR_OFF","STAN+CALL+GLAD_>=7","STAN+CALL_>=3","STAN-1.QSTN1","STAN-2.QSTN2","STAN-3.QSTN3","STAN-4.QSTN4","STANWELL1_ONSTATUS","STANWELL2_ONSTATUS","STANWELL3_ONSTATUS","STANWELL4_ONSTATUS","STAN_>=2","TVLLE/HAUGHTON_ON","TVLLE_PS_GEN_ON","TVLLE_PS_SYNCON_ON"]},"SPD_TYPE":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID describing type of data source","examples":["A","C","E","G","S","T","U"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENERICEQUATIONRHS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":22554,"decompressed_size_all_time":11151340},"visibility":"Public","trigger":"When a generic equation is created or modified"},"GENMETER":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"GENMETER","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#69"],"comment":"GENMETER shows details of generator meter sets.","description":"GENMETER is a public table, and is available to all participants.\n\nSource\n\nGENMETER updates only when meter details change.","primary_keys":["APPLYDATE","METERID","VERSIONNO"],"indexes":[["LASTCHANGED"],["STATIONID"]],"columns":{"APPLYDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Application date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"METERID":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":true,"comment":"Meter Id"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of the record for the given effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"AEMO user authorising"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Generator Set ID","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"METERCLASS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"WATT or AUXILARY"},"METERTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"LOAD"},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Station Identifier","is_categorical":true},"VOLTAGELEVEL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Voltage","is_integer":true,"num_int_bits":32},"COMDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","unused":true,"is_categorical":true},"DECOMDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When meter details change"},"GENUNITMTRINPERIOD":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#485"],"comment":"GENUNITMTRINPERIOD shows meter reading by period for each generator meter. GENUNITMTRINPERIOD covers generated power flowing into the system. It is used to calculate settlement values.","description":"GENUNITMTRINPERIOD data is confidential to the relevant participant.\n\nSource\n\nGENUNITMTRINPERIOD updated only when new meter reading files are\nsubmitted by MDAs.","unused":true,"primary_keys":["CONNECTIONPOINTID","LOCAL_RETAILER","MDA","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["STATIONID"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point NMI","is_categorical":true},"LOCAL_RETAILER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Local Retailer for this NMI"},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Relevant Metering Data Agent"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period number where 1 period ending 00:30 EST","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading date of meter data submitted","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version no of the record for the given effective date","is_integer":true,"unsigned_int":true,"num_int_bits":32},"EXPORTENERGYVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy received from the pool (MWh)","is_float":true},"EXPORTREACTIVEVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive power received from the network","is_float":true},"GENUNITID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Physical unit ID"},"IMPORTENERGYVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy sent to the pool (MWh)","is_float":true},"IMPORTREACTIVEVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive power sent to the network","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Station Identifier","is_categorical":true}},"visibility":"Private","trigger":"When new meter reading files are submitted by MDAs"},"GENUNITS":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"GENUNITS","VERSION":2},{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"GENUNITS","VERSION":3}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#80"],"comment":"GENUNITS shows Genset details for each physical unit with the relevant station.","description":"GENUNITS is a public table, and is available to all participants.\n\nSource\n\nGENUNITS updates whenever plant details change.","primary_keys":["GENSETID"],"indexes":[["LASTCHANGED"]],"columns":{"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Physical Unit identifier","examples":["ADPBA1","ADPBA1G","ADPBA1L","ADPMH1","ADPPV1","ADPPV2","ADPPV3","AGLHAL","AGLNOW1","AGLSITA1","AGLSOM","ALDGASF1","AMCORGR1","AMCORGR2","AMCORGR3","ANGAS1","ANGAS2","APD01","APD02","APPIN","APS","APS1","ARWF1_1","AS_NSW1","AVLSF1","AWABAREF","BAKING1","BALB1","BALBG1","BALBL1","BALDHWF1","BALDHWF2","BANGOWF1","BANGOWF2","BANKSPT1","BANKSPT2","BANN1","BANN2","BAPS","BARCALDN","BARCSF1","BARCSF2","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BAYNL1","BBASEHOS","BBASEH_1","BBASEH_2","BBASEH_3","BBATRY1","BBATRYL1","BBATTERY1","BBDISEL1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BDONGHYD","BELLBAY1","BELLBAY2","BERWICK","BERYLSF1","BHASZINC","BHB1","BHBG1","BHBL1","BLNKTAS","BLNKVIC","BLOWER","BLOWERNG","BLUEGSF1","BLUFF","BLULAKE1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOGONG1","BOGONG2","BOLIVAR1","BOLIVAR2","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWBA1G","BOWWBA1L","BOWWDG1","BOWWPV1","BPLANDF1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMG5","BRAEMG6","BRAEMG7","BRDDBES1","BRDDSF01","BRNDBES1","BROADMDW","BROKENH1","BROKENH2","BROOKLYN","BROWNMT","BRYB1WF1","BRYB2WF2","BULBESA1","BULBESA2","BULBESG1","BULBESL1","BULBESL2","BULGANA1","BULGANA2","BUNGAMB1","BURRIN1","BURRIN2","BURRIN3","BUSF1","BUTLERSG","BW01","BW02","BW03","BW04","BWTR1","CALLNL1","CALLNL2","CALLNL3","CALLNL4","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CAPBES1","CAPBES1G","CAPBES1L","CAPTL_WF","CATAGUN1","CATA_1","CATA_2","CATHROCK","CBWF","CBWWBA1","CBWWBA1G","CBWWBA1L","CBWWBG1","CBWWDG1","CBWWDG2","CBWWPV1","CBWWPV2","CESF1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHALLHWF","CHBESS1","CHBESSG1","CHBESSL1","CHILDSF1","CHPSTWF1","CHYTWF1","CLARESF1","CLAYTON","CLEMGPWF","CLERMSF1","CLOVER","CLOVER1","CLOVER2","CLRKCWF1","CLRKCWF2","CLUNY","CNUNDAWF","CODRNGTON","COHUNSF1","COHUNSF2","COLEASF1","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","COLUMSF1","COLWF01","COLWF02","CONDONG1","COOPGWF1","COOPGWF2","COPTNHYD","CORIO1","CPP_3","CPP_4","CPSA1","CPSA2","CPSA3","CROOK2WL","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CULLRG01","CUSF1","CUSF2","DAANDIN2","DAANDINE","DALNTH01","DALNTH1","DALNTHL1","DARLSF1","DARTM1","DAYDSF1","DAYDSF2","DDPS0","DDPS1","DDPS2","DDPS3","DDSF1","DEVILS_G","DGGRP1","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIAPUR","DLNKNSW","DLNKQLD","DPNTB1","DPNTBG1","DPNTBL1","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL1","DRYCNL2","DRYCNL3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EASTCRK","EASTCRK2","EDENVSF1","EDLRGNRD","EILDON1","EILDON2","EILDON3","ELAINWF1","EMERASF1","ENERGYB1","ENERGYB2","ENERGYB3","ENERGYB4","ENERGYB5","ER01","ER02","ER03","ER04","ERB01","ERB02","ERGT01","ERG_AS","ERNL1","FARLEIGH","FINLYSF1","FISHER","FLYCRKWF","FNWF1","FSWF1","GANGARR1","GANNB1","GANNBG1","GANNBL1","GANNSF1","GANNSF2","GANNSFL1","GB01","GB02","GE01","GE02","GE03","GE04","GEOGRTN21","GEORGTN11","GERMCRK","GESF1","GH01","GH02","GIRGSF1","GK01","GK02","GK03","GK04","GLADNL1","GLBWNHYD","GLENMAG1","GLENNCRK","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOESF2","GOONSF1","GORDON","GORDON1","GORDON2","GORDON3","GOVILLB1","GPWFEL1","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWL1","GPWFWST1","GPWFWST2","GRANGEAV","GRANWF1","GREENB1","GRIFSF1","GROSV1","GROSV2","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTH-1","GUTH-2","GUTHEGA","GUTHNL1","HALAMRD1","HALLWF1","HALLWF2","HAMISF1","HASTING1","HASTING2","HASTING3","HAUGHT11","HAYMSF1","HBESS1","HBESSG1","HBESSL1","HD1WF1","HDWF1","HDWF2","HDWF3","HEPWIND1","HEZ","HEZ1","HIGHBRY1","HILLSTN1","HLMSEW01","HPR1","HPRG1","HPRL1","HUGSF1","HUGSF2","HUMENSW1","HUMEV1","HUNTER1","HUNTER2","HVWWBA1","HVWWBA1G","HVWWBA1L","HVWWPV1","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JACKSGUL","JACKSGUL2","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KARYNL1","KEEPIT","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF11","KIAMSF12","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINCUM1","KINGASF1","KPP_1","KRCCOGEN","KSP1","LADBROK1","LADBROK2","LANCSF1","LANCSF2","LBB1","LBBG1","LBBL1","LD01","LD02","LD03","LD04","LDBESS1","LEMONTME","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LIDDNL1","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF12","LIMOSF13","LIMOSF21","LI_WY_CA","LKBONNEY2A","LKBONNEY2B","LKBONNY1","LKBONY3_1","LK_ECHO","LNGS1","LNGS2","LONGFORD","LONSDAL1","LONSDAL2","LONSDALE","LOYYB1","LOYYB2","LRSF1","LUCAS2S2","LUCASHGT","LVES1","LYA1","LYA2","LYA3","LYA4","LYGS1","LYGS2","LYGS3","LYGS4","LYGS5","LYGS6","LYNL1","L_W_CNL1","MACARTH1","MACKAYGT","MACKNADE","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MANSLR2","MAPS2PV1","MAPS3PV1","MARIAN","MAROOWF1","MARYRSF1","MBAHNTH","MBPS2PV1","MCINTYR1","MCINTYR2","MCKAY1","MCKAY2","MCKAY3","MEADOWB21","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MIDLDPS1","MINTARO","MINTNL1","MLB01","MLINKSA","MLINKVIC","MLLFGEF1","MLSP1","MLWF1","MM3","MM4","MMNL1","MOKOSF1","MOLNGSF1","MOORABS1","MOORAWF1","MORANBAH","MOREESF1","MORNL1","MORNW","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPNL1","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRIDGE","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTGELWF2","MTMILLAR","MUCRKSF1","MULGRAVE","MULWASF1","MURAYNL1","MURAYNL2","MURAYNL3","MURR1-1","MURR1-10","MURR1-2","MURR1-3","MURR1-4","MURR1-5","MURR1-6","MURR1-7","MURR1-8","MURR1-9","MURR2-1","MURR2-2","MURR2-3","MURR2-4","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NASF1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NINEWIL1","NPS","NPS1","NPS2","NPSNL1","NPSNL2","NUMURSF1","NUMURSF2","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","OAKY2_1","OCPS","ORABESS1","OSB01","OSB02","PALOONA","PAREPS1","PAREPW1","PARSF1","PEDLER1","PIBESS1","PIBESSG1","PIBESSL1","PINDARI","PIONEER1","PIONEER2","PLANECRK","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PLBESS1","PLEYSTOW","PMATTAEP","PO110NL1","POATINA1","POATINA2","POR01","POR03","PORTLAT1","PORTLAT2","PORTWF","PPGT11","PPGT12","PPST18","PTH01","PTH02","PTH03","PTINA110","PTINA220","PUMP1","PUMP2","QBYNB1","QBYNBG1","QBYNBL1","QPS1","QPS2","QPS3","QPS4","QPS5","QUERIVE1","QUERIVE2","QUERIVE3","QUORNB1","QUORNB2","RACOMIL1","RANGEB1","RCOURSE","REDBANK1","REECE1","REECE2","REMOUNT","REPULSE","RESS1","RESS1G","RESS1L","RIVNB2","RIVNBG2","RIVNBL2","ROCHEDAL","ROCKY-GT","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RRSF1","RT_NSW1","RT_QLD1","RT_SA1","RT_TAS1","RT_VIC1","RUBICON","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SAPHWF2","SATGN1","SATGS1","SEBSF1","SH01","SH02","SH03","SH04","SHEP1","SHGEN2","SHOAL1","SHP01","SHP02","SHP03","SHP04","SITHE01","SITHE02","SITHE03","SITHE04","SKSF1","SLDCBLK1","SMCSF1","SMCSF2","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUG5","SNUG6","SNUGNL1","SNWYGJP1","SNWYGJP2","SOMERSET","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STANNL1","STANV1","STANV2","STAPYLTON1","STARHLWF","STGEORG1","STGGRP1","STHBKTEC","STHJST","STOCKYD1","STPN1","STUBSF1","STUBSF2","STWF1","SUNCOAST","SUNRSF1","SUNSHINE","SUNTPSF1","SVALE1","SWANBBF1","SWANNL1","SWANNL2","SWAN_A_1","SWAN_A_2","SWAN_A_3","SWAN_A_4","SWAN_A_5","SWAN_A_6","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_C","SWAN_D","SWAN_E","SYMEX1_1","TABMILL2","TAHMOOR1","TALLA1","TALWB1","TARALGA1","TARBESS1","TARNL1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TATIARA1","TATURA01","TB2B1","TB2BGEN","TB2BLOAD","TB2SGEN","TB3B1","TBLD","TBSF1","TEATREE1","TEMPB1","TERALBA","TERMSTOR","TGNSS1","THEDROP1","TIB1","TIBG1","TIBL1","TIMWEST","TITREE","TNPS1","TOMAGO1","TOMAGO2","TOMAGO3","TOORAWF","TORNL1","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TOWER","TREVALLN","TREV_1","TREV_2","TREV_3","TREV_4","TRGBESS1","TRIBNL1","TRIBUTE","TUMT3NL1","TUMT3NL2","TUMT3NL3","TUMUT1-1","TUMUT1-2","TUMUT1-3","TUMUT1-4","TUMUT2-1","TUMUT2-2","TUMUT2-3","TUMUT2-4","TUMUT3","TUMUT3-1","TUMUT3-2","TUMUT3-3","TUMUT3-4","TUMUT3-5","TUMUT3-6","TUNGATIN","TUNGA_3","TUNGA_4","TVCC_GT1","TVCC_ST1","TVPP104","TYPHOONW","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","UWF1","UWS1","VALDORA1","VBB1","VBBG1","VBBL1","VICMILL1","VICSMLT","VICSMLT2","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VPNL1","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WALGRVG1","WALGRVL1","WAMBOWF1","WAMBOWF2","WANDB1","WANDBG1","WANDBL1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WAUBWF01","WAUBWF02","WDBESS1","WDBESS2","WDBESSG1","WDBESSL1","WDGPH1","WDGPH2","WDLNGN01","WELLSF1","WELNSF1","WEMENSF1","WESTCBT1","WESTILL1","WESTILL2","WG01","WGULLY","WGWF1","WHILL1","WHIT1","WHITSF1","WILGAPK1","WILGB01","WILLBES1","WILLHOV1","WINGF1_1","WINGF2_1","WINTSF1","WIVENSH","WKIEWA1","WKIEWA2","WLWLSF1","WLWLSF2","WNSF1","WOLARSF1","WOLARSF2","WOLLERT1","WONWP","WOODLWN1","WOOLES1","WOOLGSF1","WOOLNTH1","WOORB1","WOYWOY1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WTAHB2","WUNUSF1A","WUNUSF1B","WW7","WW8","WWNL1","WWNL2","WYA252B1","WYANGALA","WYANGALB","WYASF1","WYB252B1","WYNDW","YABULU","YABULU2","YAMBUK","YARANSF1","YARWN1_1","YATSF1","YAWWF","YENDWF1","YSWF1","YWNGAHYD","YWNL1","YWPS1","YWPS2","YWPS3","YWPS4"],"is_categorical":true},"AGCFLAG":{"sql_type":"VARCHAR2(2)","pl_type":"pl.Boolean","mandatory":false,"comment":"AGC Available flag","examples":["Y","N"],"value_map":{"Y":1,"N":0},"is_boolean":true},"CDINDICATOR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Centrally dispatched Indicator","examples":["N","Y"]},"CO2E_DATA_SOURCE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"An indicator as to the source of the emission factor used in the calculation of the index. The applicable values for this field would be NTNDP which indicates the emission factor is quoted from the National Transmission Network Development Plan or Estimated to indicate the emission factor has been calculated using an internal AEMO procedure based upon the Department of Climate Change and Energy Efficiency NGA factors","examples":["Estimate - NGA 2011","Estimate - NGA 2012","Estimate - NGA 2014","Estimate - NGA 2015","Estimate - NGA 2016","Estimate - Other","Excluded NMNS","ISP 2018","ISP 2020","ISP2020","ISP2022","ISP2024","NGA 2018","NGA 2020","NGA 2024","NGA2022","NGA2024","NTNDP 2011","NTNDP 2014","On Exclusion List"]},"CO2E_EMISSIONS_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The emissions factor for the generating unit, as calculated by Settlements staff members","examples":["0.01561827","0","1.64871738"],"is_float":true},"CO2E_ENERGY_SOURCE":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"The energy source for the generating unit, as used in the calculation of the CO2-e emissions factor. Distinct from the Energy Source for a generating unit published as part of the Registration Master List","examples":["Bagasse","Battery Storage","Biomass and industrial materials","Black coal","Brown coal","Coal Seam Methane","Coal mine waste gas","Coal seam methane","Diesel oil","Ethane","Hydro","Kerosene - non aviation","Landfill biogas methane","Natural Gas (Pipeline)","Other Biofuels","Other solid fossil fuels","Primary solid biomass fuels","Solar","Wind"]},"DISPATCHTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"GROSS/NET\", \"NET/NET\"])","mandatory":false,"comment":"Type NET/NET identifies if DUID is a Scheduled and GROSS/NET identifies if DUID is either Semi-Scheduled or Non-Scheduled.","examples":null,"warnings":["The values here differ from the same column in other tables."],"enums":["GROSS/NET","NET/NET"]},"GENSETNAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Genset name"},"GENSETTYPE":{"sql_type":"VARCHAR2(15)","pl_type":"pl.Categorical","mandatory":false,"comment":"Identifies LOAD, GENERATOR or BIDIRECTIONAL. This will likely expand to more generic models as new technology types are integrated into the NEM.","examples":["BIDIRECTIONAL","GENERATOR","LOAD"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2005/11/23 09:55:53"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum capacity","examples":["1","3756"],"is_integer":true,"num_int_bits":32},"MAXSTORAGECAPACITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The rated storage capacity (MWh), information only","examples":["4.8","2","1997"],"is_float":true},"MINCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Minimum capacity only for load side of BDU, otherwise 0 (MW)","examples":["2","500"],"is_integer":true,"num_int_bits":32},"MKTGENERATORIND":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Boolean","mandatory":false,"comment":"Market Generator Indicator Flag","examples":["Y","N"],"value_map":{"Y":1,"N":0},"is_boolean":true},"NORMALSTATUS":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Boolean","mandatory":false,"comment":"On / Off for load","examples":["Y","N"],"warnings":["Despite AEMO's description of On/Off, this actually takes values `Y` and `N`. This differs from columns with the same name in other tables (which use `ON` and `OFF`)."],"parse_csv_as_string":true,"value_map":{"Y":1,"N":0},"is_boolean":true},"REGISTEREDCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Registered capacity","examples":["1","3756"],"is_integer":true,"num_int_bits":32},"REGISTEREDMINCAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Registered minimum capacity only for load side of BDU, otherwise 0 (MW)","examples":["2","755"],"is_integer":true,"num_int_bits":32},"STARTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Fast / Slow / Not Dispatched","examples":["FAST","SLOW"]},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Station Identifier","is_categorical":true},"VOLTLEVEL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Voltage level","examples":["1","500"],"is_integer":true,"num_int_bits":32},"SETLOSSFACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"SPINNINGFLAG":{"sql_type":"VARCHAR2(2)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","examples":["N","Y"],"unused":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENUNITS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":15267,"decompressed_size_all_time":15847830},"visibility":"Public","trigger":"When plant details change"},"GENUNITS_UNIT":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"GENUNITS_UNIT","VERSION":1},{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"GENUNITS_UNIT","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#89"],"comment":"Physical units within a Gen Unit Set","primary_keys":["EFFECTIVEDATE","GENSETID","UNIT_GROUPING_LABEL","VERSIONNO"],"indexes":[["GENSETID","EFFECTIVEDATE","VERSIONNO","UNIT_GROUPING_LABEL"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective Date of this detail record","examples":["2010/10/27 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"System wide unique Generating Set ID","examples":["AGLHAL","AGLNOW1","AGLSOM","AMCORGR1","AMCORGR2","AMCORGR3","ANGAS1","ANGAS2","APD01","APPIN","APS","ARWF1_1","AWABAREF","BALDHWF1","BALDHWF2","BANKSPT1","BANKSPT2","BARCALDN","BARRON-1","BARRON-2","BASTYAN","BBASEHOS","BBASEH_1","BBASEH_2","BBASEH_3","BBDISEL1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BDONGHYD","BERWICK","BLOWERNG","BLUFF","BLULAKE1","BOCORWF1","BOGONG1","BOGONG2","BOLIVAR1","BPLANDF1","BRAEMAR1","BRAEMAR2","BRAEMG5","BRAEMG7","BROADMDW","BROKENH1","BROKENH2","BROOKLYN","BROWNMT","BURRIN1","BW01","BW02","BW03","BW04","BWTR1","CALLNL4","CALL_A_2","CALL_A_4","CALL_B_1","CALL_B_2","CAPTL_WF","CATAGUN1","CATHROCK","CBWF","CBWWBA1","CESF1","CETHANA","CG1","CG3","CHBESS1","CHPSTWF1","CLAYTON","CLEMGPWF","CLOVER","CNUNDAWF","CODRNGTON","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","CONDONG1","COPTNHYD","CORIO1","CPP_3","CPP_4","CPSA1","CPSA2","CPSA3","CULLRG01","CUSF1","CUSF2","DAANDIN2","DAANDINE","DARTM1","DDPS0","DDPS1","DDPS2","DDPS3","DEVILS_G","DRYCGT1","DRYCGT2","DRYCGT3","EASTCRK","EDLRGNRD","EILDON1","EILDON2","EILDON3","ENERGYB1","ENERGYB2","ENERGYB3","ENERGYB4","ENERGYB5","ER01","ER02","ER03","ER04","ERB01","ERGT01","FISHER","GEOGRTN21","GEORGTN11","GERMCRK","GH01","GH02","GLBWNHYD","GLENMAG1","GLENNCRK","GORDON","GOVILLB1","GRANGEAV","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GULLRWF1","GUNNING1","GUTHEGA","HALAMRD1","HALLWF1","HALLWF2","HDWF1","HEPWIND1","HEZ","HIGHBRY1","HLMSEW01","HUMENSW1","HUMEV1","HVWWBA1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JACKSGUL","JACKSGUL2","JBUTTERS","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","JOUNAMA1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KEEPIT","KINCUM1","KPP_1","KRCCOGEN","LADBROK1","LADBROK2","LBB1","LD01","LD02","LD03","LD04","LEM_WIL","LIMOSF13","LI_WY_CA","LKBONNEY2A","LKBONNEY2B","LKBONNY1","LKBONY3_1","LK_ECHO","LNGS1","LNGS2","LONGFORD","LONSDAL1","LONSDAL2","LONSDALE","LOYYB1","LOYYB2","LUCAS2S2","LUCASHGT","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKAYGT","MACKNADE","MACKNTSH","MBAHNTH","MCINTYR2","MCKAY1","MCKAY2","MCKAY3","MEADOWB21","MEADOWBK","MERCER01","MIDLDPS1","MINTARO","MLWF1","MM3","MM4","MORANBAH","MOREESF1","MORNW","MORTLK11","MORTLK12","MP1","MP2","MPP_1","MPP_2","MREHA1","MSTUART1","MSTUART2","MSTUART3","MTMILLAR","MURRAY","MUSSELR1","NBHWF1","NINEWIL1","NPS","NPS1","NPS2","NYNGAN1","OAKEY1","OAKEY2","OAKLAND1","OAKY2_1","OCPS","OSB01","OSB02","PALOONA","PEDLER1","PINDARI","PIONEER1","PIONEER2","PLAYFB1","PLAYFB2","PLAYFB3","PLAYFB4","PMATTAEP","POR01","POR03","PORTLAT1","PORTLAT2","PORTWF","PPGT11","PPGT12","PPST18","PTH01","PTH02","PTH03","PTINA110","PTINA220","PUMP1","PUMP2","QPS1","QPS2","QPS3","QPS4","QPS5","QUERIVE1","QUERIVE2","QUERIVE3","RACOMIL1","REDBANK1","REECE1","REECE2","REMOUNT","REPULSE","ROCHEDAL","ROMA_7","ROMA_8","ROWALLAN","ROYALLA1","RPCG","RUBICON","SH01","SH02","SH03","SH04","SHEP1","SHP01","SHP02","SHP03","SHP04","SITHE01","SITHE02","SITHE03","SITHE04","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYGJP","SNOWYP","SNUG1","SNUG2","SNUG3","SNUG4","SNUG5","SNUG6","SOMERSET","STAN-1","STAN-2","STAN-3","STAN-4","STANV1","STANV2","STARHLWF","STHBKTEC","SUNCOAST","SUNSHINE","SVALE1","SWANNL2","SWAN_B_1","SWAN_B_2","SWAN_B_3","SWAN_B_4","SWAN_E","SYMEX1_1","TAHMOOR1","TALLA1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TATIARA1","TATURA01","TB2B1","TEATREE1","TERALBA","TERMSTOR","TGNSS1","THEDROP1","TITREE","TNPS1","TOORAWF","TORRA1","TORRA2","TORRA3","TORRA4","TORRB1","TORRB2","TORRB3","TORRB4","TOWER","TREVALLN","TRIBUTE","TUMUT3","TUNGATIN","TVCC_GT1","TVCC_ST1","TVPP104","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VICMILL1","VICSMLT","VICSMLT2","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WALGRV1","WAMBOWF1","WATERLWF","WAUBWF01","WAUBWF02","WDBESS1","WDLNGN01","WESTCBT1","WESTILL1","WESTILL2","WG01","WHILL1","WHIT1","WILGAPK1","WILGB01","WILLHOV1","WINGF1_1","WINGF2_1","WIVENSH","WKIEWA1","WKIEWA2","WOLLERT1","WONWP","WOODLWN1","WOOLNTH1","WOYWOY1","WPWF","WW7","WW8","WYA252B1","WYANGALA","WYANGALB","WYB252B1","WYNDW","YABULU","YABULU2","YAMBUK","YARWN1_1","YWNGAHYD","YWPS1","YWPS2","YWPS3","YWPS4"],"is_categorical":true},"UNIT_GROUPING_LABEL":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Label of Physical Units within the station","examples":["0","1","01-4","39","05-6","07-10","1 & 2","1 - 23","1 - 56","1,2,4","1-1","1-10","1-11","1-112","1-12","1-13","1-14","1-140","1-15","1-154","1-16","1-164","1-17","1-18","1-2","1-20","1-21","1-23","1-24","1-25","1-27","1-28","1-29","1-3","1-31","1-32","1-33","1-34","1-35","1-36","1-37","1-4","1-40","1-42","1-45","1-46","1-47","1-48","1-5","1-53","1-54","1-55","1-56","1-58","1-6","1-63","1-64","1-67","1-7","1-8","1-80","1-81","1-82","1-9","10-18","11-12","12-15","12-19","12-31","15-16","16-30","17-20","18-73","19 - 36","1b","2-2","2-3","2-6","22-42","22-53","25-48","29-38","2b","3-11","3-4","3-6","30-52","33-75","4-5","4-6","40-52","41-80","43-51","49-60","5 - 6","5-6","5-8","56-111","59-67","6-6","6-8","6-9","82-128","82-162","C 1-2","CNN","CWG_MM82","CWG_MM92","GT 1-2","GT 1-4","GT 2-1","GT 2-2","GT 2-3","GT 2-4","GT 3-1","GT 3-2","L 1","L 1-3","PL3","PRTLCBW_C1","PRTLCNS_C2","W 1","W 1-3","WBP 1-37","WKIEWA1","WKIEWA2","WSB 1-25","WW7","WW8"]},"VERSIONNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version with respect to the effective date","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"AGGREGATION_FLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Deprecated as this flag is moved to DUDETAIL table with IESS release.","examples":["0","1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time when record was changed","examples":["2010/12/16 08:09:53"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXSTORAGECAPACITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The rated storage capacity (MWh), information only","examples":["0.4","0","7.7"],"is_float":true},"REGISTEREDCAPACITY":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Registered capacity for normal operations","examples":["0.011","0","1","1500"],"is_float":true},"REGISTEREDMINCAPACITY":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Only applicable for the LOAD side of BDU (MW)","examples":["0.4","0","4.39"],"is_float":true},"UNIT_COUNT":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Number of units in this Gen Unit grouping","examples":["1","164"],"is_integer":true,"num_int_bits":64},"UNIT_MAX_SIZE":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Capacity for each unit in this grouping","examples":["0.4","2","42.65","760"],"is_float":true},"UNIT_SIZE":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Nameplate Capacity for each unit in this grouping","examples":["0.011","1","140.6","750"],"is_float":true},"UNITMINSIZE":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Only applicable for the LOAD side of BDU (MW)","examples":["0.4","0","3.28"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GENUNITS_UNIT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":33449,"decompressed_size_all_time":8255610},"visibility":"Public","trigger":"When plant details change"},"GST_BAS_CLASS":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"GST_BAS_CLASS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#10"],"comment":"GST_BAS_CLASS contains a static list of BAS (Business Activity Statement) classifications supported by the MMS.","description":"GST_BAS_CLASS data is public to all participants.","primary_keys":["BAS_CLASS"],"indexes":[["LASTCHANGED"]],"columns":{"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The BAS classification","examples":["ACQUISITIONS_WITH_NO_GST","CREDITABLE_ACQUISITIONS","GST_FREE_SUPPLIES","INPUT_TAXED_SUPPLIES","NOT_SUBJECT_TO_GST","TAXABLE_SUPPLIES"]},"DESCRIPTION":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Description of the BAS classification","examples":["Acquisition with no GST in the price","Creditable Acquisitions","GST Free Supplies","Input Taxed Supplies","Not subject to GST","Taxable Supplies"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2000/07/05 15:03:20"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GST_BAS_CLASS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":571,"decompressed_size_all_time":761310},"visibility":"Public"},"GST_RATE":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"GST_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#19"],"comment":"GST_RATE maintains the GST rates on a BAS (Business Activity Statement) class basis.","description":"GST_RATE data is public to all participants.","primary_keys":["BAS_CLASS","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The BAS classification","examples":["ACQUISITIONS_WITH_NO_GST","CREDITABLE_ACQUISITIONS","GST_FREE_SUPPLIES","INPUT_TAXED_SUPPLIES","NOT_SUBJECT_TO_GST","TAXABLE_SUPPLIES"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of the data set","examples":["2000/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The version number of the data set","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"GST_RATE":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The GST rate that applies to this BAS classification","examples":["0","10"],"is_float":true,"col_name_also_metadata":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2000/05/05 14:46:49"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GST_RATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":474,"decompressed_size_all_time":622060},"visibility":"Public","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns GST_RATE. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}]},"GST_TRANSACTION_CLASS":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"GST_TRANSACTION_CLASS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#28"],"comment":"GST_TRANSACTION_CLASS maps NEM settlement transaction types with BAS (Business Activity Statement) classifications.","description":"GST_TRANSACTION_CLASS data is public to all participants.\n\nSource\n\nGST_TRANSACTION_CLASS updates infrequently, when new transactions are\nintroduced to the NEM.\n\nVolume\n\nGenerally volume is fewer than one hundred records.","primary_keys":["BAS_CLASS","EFFECTIVEDATE","TRANSACTION_TYPE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BAS_CLASS":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The BAS classification that the transaction type corresponds to","examples":["ACQUISITIONS_WITH_NO_GST","CREDITABLE_ACQUISITIONS","GST_FREE_SUPPLIES","INPUT_TAXED_SUPPLIES","NOT_SUBJECT_TO_GST","TAXABLE_SUPPLIES"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of the data set","examples":["2000/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"TRANSACTION_TYPE":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM settlement transaction type","examples":["ANCILLARY_PAYMENT","ANCILLARY_RECOVERY","APC_PAYMENT","APC_RECOVERY","CUSTOMER_ENERGY_PURCHASE","CUSTOMER_ENERGY_SALE","DIR_AFF_CUST_PAID","DIR_AFF_CUST_PAYABLE","DIR_AFF_ELIG","DIR_AFF_ELIG_NEGATIVE","DIR_AFF_NON_ELIG_PAID","DIR_AFF_NON_ELIG_PAYABLE","DIR_COMP","DIR_FUNDING_PAID","DIR_FUNDING_PAYABLE","DIR_INTEREST_PAID","DIR_INTEREST_PAYABLE","DIR_NET_AFF_CUST_PAID","DIR_NET_AFF_CUST_PAYABLE","DIR_NET_AFF_ELIG_PAID","DIR_NET_AFF_ELIG_PAYABLE","DIR_NET_AFF_NON_ELIG_PAID","DIR_NET_AFF_NON_ELIG_PAYABLE","DIR_NET_COMP_PAID","DIR_NET_COMP_PAYABLE","DIR_NET_FUNDING_PAID","DIR_NET_FUNDING_PAYABLE","DIR_NET_SPOT_PAID","DIR_NET_SPOT_PAYABLE","DIR_SPOT_ENTITLEMENT","EARLY_PAYMENT_INTEREST","EARLY_PAYMENT_INTEREST_BAL","FEE_F_5MSGS_WP","FEE_F_ALO_GEN","FEE_F_ALO_MG","FEE_F_ALO_MSG","FEE_F_ALO_WP","FEE_F_COMA_REV","FEE_F_DER_WP","FEE_F_EST_NECA","FEE_F_EST_NEMM","FEE_F_EUA_NECA","FEE_F_FRC","FEE_F_GEN_NECA","FEE_F_GEN_NEMM","FEE_F_GEN_REV","FEE_F_MG_REV","FEE_F_MSG_REV","FEE_F_PAR_COMA","FEE_F_SVC_IT","FEE_V_5MSGS_CP","FEE_V_5MSGS_MC","FEE_V_ALO_CP","FEE_V_ALO_CUST","FEE_V_CUST_NSM","FEE_V_CUST_NTP","FEE_V_DER_CP","FEE_V_DER_MC","FEE_V_ECA","FEE_V_ECA2","FEE_V_EST_FRC","FEE_V_EST_NECA","FEE_V_EST_NEMM","FEE_V_EUA","FEE_V_EUA_NECA","FEE_V_FRC","FEE_V_FRC_CUS2","FEE_V_FRC_CUST","FEE_V_GEN_CP","FEE_V_GEN_FRC","FEE_V_GEN_NECA","FEE_V_GEN_NEMM","FEE_V_NET_NECA","FEE_V_PAR_COMA","GENERATOR_ENERGY_PURCHASE","GENERATOR_ENERGY_SALE","INTERVENTION_PAYMENT","INTERVENTION_RECOVERY","INTRARESIDUE_PAID","INTRARESIDUE_PAYABLE","IRFM_RECOVERY","MR_PAYMENT","MR_RECOVERY","MR_SHORTFALL_PAID","MR_SHORTFALL_PAYABLE","REALLOCATION_CREDIT","REALLOCATION_DEBIT","REASSIGNMENT_FROM","REASSIGNMENT_TO","RESERVETRADER_PAYMENT","RESERVETRADER_RECOVERY","REVISION_AMOUNT","REVISION_INTEREST_PAID","REVISION_INTEREST_PAYABLE","REVISION_INTEREST_PREGST","SAPS_ENERGY_PURCHASE","SAPS_ENERGY_SALE","SECURITY_DEPOSIT_APPLICATION","SECURITY_DEPOSIT_INTEREST","SECURITY_DEPOSIT_INTEREST_BAL","SMELTER_PAYMENT","SMELTER_RECOVERY","SNOWYCSP_DEROGATION_PAID","SNOWYCSP_DEROGATION_PAYABLE","SRA_AUCTION_FEES","SRA_AUC_RESIDUE_PAID","SRA_AUC_RESIDUE_PAYABLE","SRA_NSP_PROCEEDS","SRA_NSP_RESIDUE_PAID","SRA_NSP_RESIDUE_PAYABLE","SRA_PART_RESIDUE","SRA_RECONCILIATION","WDR_PAID","WDR_PAYABLE","WHITEHOLE_RECOVERY"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The version number of the data set","examples":["1","3"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2003/06/03 09:46:28"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GST_TRANSACTION_CLASS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":8344,"decompressed_size_all_time":5763360},"visibility":"Public","trigger":"When new transactions are introduced to the NEM"},"GST_TRANSACTION_TYPE":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"GST_TRANSACTION_TYPE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#37"],"comment":"GST_TRANSACTION_TYPE shows a static list of transaction types supported by the MMS.","description":"GST_TRANSACTION_TYPE data is public to all participants.","primary_keys":["TRANSACTION_TYPE"],"indexes":[["LASTCHANGED"]],"columns":{"TRANSACTION_TYPE":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"The transaction type","examples":["ANCILLARY_PAYMENT","ANCILLARY_RECOVERY","APC_PAYMENT","APC_RECOVERY","CUSTOMER_ENERGY_PURCHASE","CUSTOMER_ENERGY_SALE","DIR_AFF_CUST_PAID","DIR_AFF_CUST_PAYABLE","DIR_AFF_ELIG","DIR_AFF_ELIG_NEGATIVE","DIR_AFF_NON_ELIG_PAID","DIR_AFF_NON_ELIG_PAYABLE","DIR_COMP","DIR_FUNDING_PAID","DIR_FUNDING_PAYABLE","DIR_INTEREST_PAID","DIR_INTEREST_PAYABLE","DIR_NET_AFF_CUST_PAID","DIR_NET_AFF_CUST_PAYABLE","DIR_NET_AFF_ELIG_PAID","DIR_NET_AFF_ELIG_PAYABLE","DIR_NET_AFF_NON_ELIG_PAID","DIR_NET_AFF_NON_ELIG_PAYABLE","DIR_NET_COMP_PAID","DIR_NET_COMP_PAYABLE","DIR_NET_FUNDING_PAID","DIR_NET_FUNDING_PAYABLE","DIR_NET_SPOT_PAID","DIR_NET_SPOT_PAYABLE","DIR_SPOT_ENTITLEMENT","EARLY_PAYMENT_INTEREST","EARLY_PAYMENT_INTEREST_BAL","FEE_F_5MSGS_WP","FEE_F_ALO_GEN","FEE_F_ALO_MG","FEE_F_ALO_MSG","FEE_F_ALO_WP","FEE_F_COMA_REV","FEE_F_CYB_WP","FEE_F_DER_WP","FEE_F_EST_NECA","FEE_F_EST_NEMM","FEE_F_EUA_NECA","FEE_F_FRC","FEE_F_GEN_NECA","FEE_F_GEN_NEMM","FEE_F_GEN_REV","FEE_F_MG_REV","FEE_F_MSG_REV","FEE_F_NEM25WP","FEE_F_PAR_COMA","FEE_F_SVC_IT","FEE_MC_5MS_AC1","FEE_MC_5MS_AC2","FEE_MC_5MS_AS1","FEE_MC_5MS_AS2","FEE_MC_5MS_CP","FEE_MC_COR_AC1","FEE_MC_COR_AC2","FEE_MC_COR_AS1","FEE_MC_COR_AS2","FEE_MC_COR_CP","FEE_MC_CYB_AC1","FEE_MC_CYB_AC2","FEE_MC_CYB_AS1","FEE_MC_CYB_AS2","FEE_MC_CYB_CP","FEE_MC_ECA_CP","FEE_MC_REF_AC1","FEE_MC_REF_AC2","FEE_MC_REF_AS1","FEE_MC_REF_AS2","FEE_MC_REF_CP","FEE_MC_RET_CP","FEE_V_5MGS_CP2","FEE_V_5MGS_MC2","FEE_V_5MGS_MC3","FEE_V_5MSGS_CP","FEE_V_5MSGS_MC","FEE_V_ALO_CP","FEE_V_ALO_CP2","FEE_V_ALO_CUS2","FEE_V_ALO_CUS3","FEE_V_ALO_CUST","FEE_V_CUST_NSM","FEE_V_CUST_NTP","FEE_V_CYB_CP","FEE_V_CYB_CP2","FEE_V_CYB_MC","FEE_V_CYB_MC2","FEE_V_CYB_MC3","FEE_V_DER_CP","FEE_V_DER_CP2","FEE_V_DER_MC","FEE_V_DER_MC2","FEE_V_DER_MC3","FEE_V_ECA","FEE_V_ECA2","FEE_V_ECA3","FEE_V_EST_FRC","FEE_V_EST_NECA","FEE_V_EST_NEMM","FEE_V_EUA","FEE_V_EUA_NECA","FEE_V_FRC","FEE_V_FRC_CUS2","FEE_V_FRC_CUS3","FEE_V_FRC_CUST","FEE_V_GEN_CP","FEE_V_GEN_CP2","FEE_V_GEN_FRC","FEE_V_GEN_NECA","FEE_V_GEN_NEM2","FEE_V_GEN_NEM3","FEE_V_GEN_NEMM","FEE_V_NEM25CP","FEE_V_NEM25CP2","FEE_V_NEM25MC","FEE_V_NEM25MC2","FEE_V_NEM25MC3","FEE_V_NET_NECA","FEE_V_PAR_COMA","FEE_WP_5MS","FEE_WP_COR","FEE_WP_CYB","FEE_WP_PCF","FEE_WP_REF","FPP_AMOUNT_PAID","FPP_AMOUNT_PAYABLE","GENERATOR_ENERGY_PURCHASE","GENERATOR_ENERGY_SALE","INTERVENTION_PAYMENT","INTERVENTION_RECOVERY","INTRARESIDUE_PAID","INTRARESIDUE_PAYABLE","IRFM_RECOVERY","MR_PAYMENT","MR_RECOVERY","MR_SHORTFALL_PAID","MR_SHORTFALL_PAYABLE","NEM_ENERGY_PURCHASE","NEM_ENERGY_SALE","REALLOCATION_CREDIT","REALLOCATION_DEBIT","REASSIGNMENT_FROM","REASSIGNMENT_TO","RESERVETRADER_PAYMENT","RESERVETRADER_RECOVERY","REVISION_AMOUNT","REVISION_INTEREST_PAID","REVISION_INTEREST_PAYABLE","REVISION_INTEREST_PREGST","SAPS_ENERGY_PURCHASE","SAPS_ENERGY_SALE","SECURITY_DEPOSIT_APPLICATION","SECURITY_DEPOSIT_INTEREST","SECURITY_DEPOSIT_INTEREST_BAL","SMELTER_PAYMENT","SMELTER_RECOVERY","SNOWYCSP_DEROGATION_PAID","SNOWYCSP_DEROGATION_PAYABLE","SRA_AUCTION_FEES","SRA_AUC_RESIDUE_PAID","SRA_AUC_RESIDUE_PAYABLE","SRA_NSP_PROCEEDS","SRA_NSP_RESIDUE_PAID","SRA_NSP_RESIDUE_PAYABLE","SRA_PART_RESIDUE","SRA_RECONCILIATION","WDR_PAID","WDR_PAYABLE","WHITEHOLE_RECOVERY"]},"DESCRIPTION":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Description of the transaction type","examples":["Additional IT Services","Administered Price Cap Payments","Administered Price Cap Recovery","Affected Participant Negative Provisional Compensation (eligible persons)","Affected Participant Negative net Final Determination Compensation (eligible persons)","Affected Participant Provisional Compensation (eligible persons)","Affected Participant Provisional Compensation (excepting eligible persons)","Affected Participant net Final Determination Compensation (eligible persons)","Affected Participant net Final Determination Compensation (excepting eligible persons)","Allocated Fee per Connection Point","Ancillary Services Payments","Ancillary Services Recovery","Compensation Funding","Customer Energy Purchases","Customer Energy Sale","Cyber Security Fee per Connection Point","Cyber Security Variable Fee","Cyber Security Variable Fee - BDU","Cyber Security Variable Fee - CUST","DER Fee per Connection Point","DER Variable Fee","DER Variable Fee - BDU","DER Variable Fee - CUST","Directed Participant NEMMCO Spot entitlement","Directed Participant Provisional Compensation","Directed Participant net Final Determination ","Directed and Affected Participant net Final Determination Funding","Early Payment Interest NEMMCO Side","Energy Consumers Australia","Energy Consumers Australia per Small CP - MARKET","FRC Establishment ","FRC Operations","FRC Operations from 1 July 2019","Fee included for FPP funding purposes","Final Determination Interest For Affected and Directed Participants","Frequency Performance Payment Paid by AEMO","Frequency Performance Payment Payable to AEMO","Generator Energy Purchases","Generator Energy Sales","IT Upgrade and 5MS/GS Compliance Fee - BDU","IT Upgrade and 5MS/GS Compliance Fee - CUST","IT Upgrade and 5MS/GS Compliance Variable Fee","IT Upgrade and 5MS/GS Fee per Connection Point","Industrial Relations Force Majeure Recovery","Interest on Early Payment amounts","Intervention Interval Payments","Intervention Interval Recovery","Intra-regional Residue Payment","MC Cyber Security per ACE MWh - CUSTOMER","MC Cyber Security per ACE MWh - IRP","MC Cyber Security per ASOE MWh - CUSTOMER","MC Cyber Security per ASOE MWh - IRP","MC Cyber Security per CP - MARKET","MC Electricity Retail per Small/Large CP - MARKET","MC IT Upgrade and 5MS/GS per ACE MWh - CUSTOMER","MC IT Upgrade and 5MS/GS per ACE MWh - IRP","MC IT Upgrade and 5MS/GS per ASOE MWh - CUSTOMER","MC IT Upgrade and 5MS/GS per ASOE MWh - IRP","MC IT Upgrade and 5MS/GS per CP - MARKET","MC NEM Core per ACE MWh - CUSTOMER","MC NEM Core per ACE MWh - IRP","MC NEM Core per ASOE MWh - CUSTOMER","MC NEM Core per ASOE MWh - IRP","MC NEM Core per CP - MARKET","MC NEM Reform per ACE MWh - CUSTOMER","MC NEM Reform per ACE MWh - IRP","MC NEM Reform per ASOE MWh - CUSTOMER","MC NEM Reform per ASOE MWh - IRP","MC NEM Reform per CP - MARKET","Mandatory Restriction Paid by NEMMCO","Mandatory Restriction Paid to NEMMCO","Mandatory Restriction Payments","Mandatory Restriction Recovery","Market AND Scheduled Gen & MNSP Allocated Fee","Market Customer Allocated Fee","Market Customer Allocated Fee - BDU","Market Customer Allocated Fee - CUST","Market Customer Provisional Participant Compensation","Market Customer net Final Determination Participant Compensation","Market Fee - End User Advocacy Variable Fee","Market Fee - Energy Consumers Australia Variable Fee","Market Fee - FRC Operations Variable Fee","Market Fee - NECA End User Advocacy Fixed Fee","Market Fee - NECA End User Advocacy Variable Fee","Market Fee - NECA Establishment Fixed Fee","Market Fee - NECA Establishment Variable Fee","Market Fee - NECA General Fixed fee","Market Fee - NECA General Variable Fee","Market Fee - NEMMCO Establishment Fixed Fee","Market Fee - NEMMCO Establishment Variable Fee","Market Fee - NEMMCO General Fixed Fee","Market Fee - NEMMCO General Variable Free","Market Fee - NEMMCO PCF 00/01","Market Fee - Retail Contestability Fixed Fee","Market Fee - Retail Contestability Variable Fee","Market Gen & MNSP Allocated Fee","Market OR Scheduled Gen & MNSP Allocated Fee","NEM Energy Generated (Sentout)","NEM Energy Purchased (Consumption)","NEM Variable Fee - BDU","NEM Variable Fee - CUST","NEM2025 Market Reform Fee per Connection Point","NEM2025 Market Reform Variable Fee","NEM2025 Market Reform Variable Fee - BDU","NEM2025 Market Reform Variable Fee - CUST","National Electricity Tribunal Fee","National Smart Metering","National Transmission Planner","Negative Intra-regional Residue","Negative Settlement Residue Auciton Distribution to NSP's for unpurchased units","Negative Settlement Residue Distribution to NSP's for derrogation amounts","Participant Compensation Fund","Participant Compensation Fund per day","Payment amounts for reserve trader contracts","Reallocation Credit","Reallocation Debit","Recovery amounts for reserve trader contracts","Revision Adjustment from previous billing week.","Revision Interest paid to participant","Revision Interest payable by participant","Revision Interest prior to GST","SAPS Energy Generated","SAPS Energy Purchased","Security Deposit Application to participant","Security Deposit Interest Balance - NEMMCO Side","Security Deposit Interest to participant","Settlement Residue Auction Distribution to NSP's for unpurchased units","Settlement Residue Auction Distribution to Participants","Settlement Residue Auction Fees","Settlement Residue Auction Minimum $10 payment","Settlement Residue Auction NSP Proceeds","Settlement Residue Distribution to NSP's for derrogation amounts","Smelter Reduction Payments","Smelter Reduction Recovery","Snowy CSP Derogation amounts paid to the SNOWY participant","Snowy CSP Derogation amounts payable by the SNOWY participant","Spot Entitlement net Final Determination","Statement Reassignment From Reassignor","Statement Reassignment To Reassignee","Variable Fee per Connection Point","WP Cyber Security per day","WP IT Upgrade and 5MS/GS per day","WP NEM Core per day","WP NEM Reform per day","White Hole Recovery","Wholesale Demand Response Paid","Wholesale Demand Response Payable","Wholesale participants Cyber Security Fee","Wholesale participants DER fee","Wholesale participants IT Upgrade and 5MS/GS Compliance fee","Wholesale participants NEM2025 Market Reform Fee","Wholesale participants allocated fee"]},"GL_FINANCIALCODE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"examples":["25","4800"]},"GL_TCODE":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"examples":["20","4240"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2003/06/03 09:46:27"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23GST_TRANSACTION_TYPE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3384,"decompressed_size_all_time":3591670},"visibility":"Public","trigger":"When new transactions are introduced to the NEM"},"INSTRUCTIONSUBTYPE":{"package":"GD_INSTRUCT","pdr_config":{"mappings":[{"REPORT_NAME":"GD_INSTRUCT","REPORT_SUB_TYPE":"INSTRUCTIONSUBTYPE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec27.htm#14"],"comment":"Each Dispatch instruction (GD instruct) has a type and subtype. INSTRUCTIONSUBTYPE, together with INSTRUCTIONTYPE, sets out valid instruction types.","description":"INSTRUCTIONSUBTYPE is public data, and is available to all participants.\n\nSource\n\nINSTRUCTIONSUBTYPE shows ad hoc updates to market configuration.","primary_keys":["INSTRUCTIONSUBTYPEID","INSTRUCTIONTYPEID"],"indexes":[["LASTCHANGED"]],"columns":{"INSTRUCTIONSUBTYPEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Subtype for each dispatch instruction type, for example governor off.","examples":["AGCOFF","AGCONNREG","AGCONREG","COMMENT","COMP_OFF","COMP_ON","CONST_OFF","CONST_ON","CONST_TERM","DISPLD_OFF","DISPLD_ON","FCASENABLE","FCASOFF","GOV60L","GOV60LOFF","GOV60R","GOV60ROFF","GOV6L","GOV6LOFF","GOV6R","GOV6ROFF","GOVENABLE","GOVOFF","LSENAB_MAN","LSENAB_UF","LS_DISAB","LS_OCCUR","LS_RST","MW","NON_CONFRM","NON_RESPND","OFF","OFFSYNCOMP","ONSYNCOMP","ON_PUMP","RGUL_ENAB","RGUL_ENABS","RGUL_OFF","RGUL_USED","RGUU_ENAB","RGUU_OFF","RGUU_USED","RSV_AVAIL","RSV_DISAB","RSV_ENAB","SYNCH_GEN"]},"INSTRUCTIONTYPEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Instruction type","examples":["AS_FC","AS_LS","AS_RGUL","AS_RGUU","AS_RP","GENERAL","NC","RTC","SD"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of instruction subtype","examples":["AGC Dispatch Off","AGC Dispatch on non-regulating","AGC Dispatch on regulating","Change output to specified MW by specified time","Constrain Unit Off for Frequency Control","Constrain Unit On for Frequency Control","Constrain Unit Terminated","Constrain Unit off for Reactive Power","Constrain Unit on for Reactive Power","Disable Load Shed Block","Disable reserve contract","Dispatchable Load Off","Dispatchable Load On","Enable load shed block for manual trip","Enable load shed block for under frequency trip","Enable reserve contract","Frequency Control Disable","Frequency Control Enabled","Governor off for 6 second lower","Governor off for 6 second raise","Governor off for 60 second lower","Governor off for 60 second raise","Governor on for 6 and 60 second raise and lower","Governor on for 6 second lower","Governor on for 6 second raise","Governor on for 60 second lower","Governor on for 60 second raise","Instructions as required","Load Shedding Occured","Load Shedding Stopped","Make reserve contract available","Off Line","Off as synchronous compensator","On as synchronous compensator","Rapid Gen Unit Loading Enabled","Rapid Gen Unit Loading Enabled (Spinning)","Rapid Gen Unit Loading Off","Rapid Gen Unit Loading Used","Rapid Gen Unit Unloading Constrained","Rapid Gen Unit Unloading Constraint Terminated","Rapid Gen Unit Unloading Enabled","Rapid Gen Unit Unloading Off","Rapid Gen Unit Unloading Used","Start Pump","Synchronise Generator","Terminate RGUL Unit Constraint ","Terminate unit constraint for Reactive Power","Un-Enable Governor Control Services","Unit declared as non-conforming","Unit not responding to dispatch instructions - please correct"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1999/04/20 14:56:19"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INSTRUCTIONSUBTYPE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1332,"decompressed_size_all_time":1826450},"visibility":"Public","trigger":"Ad hoc"},"INSTRUCTIONTYPE":{"package":"GD_INSTRUCT","pdr_config":{"mappings":[{"REPORT_NAME":"GD_INSTRUCT","REPORT_SUB_TYPE":"INSTRUCTIONTYPE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec27.htm#23"],"comment":"Dispatch instruction (GD instruct) has types and subtypes. INSTRUCTIONTYPE, together with INSTRUCTIONSUBTYPE, sets out valid instruction types.","description":"INSTRUCTIONTYPE data is public to all participants.\n\nSource\n\nINSTRUCTIONTYPE shows ad hoc updates to market configuration.","primary_keys":["INSTRUCTIONTYPEID"],"indexes":[["LASTCHANGED"]],"columns":{"INSTRUCTIONTYPEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Dispatch instruction type for example FCAS service.","examples":["AS_FC","AS_LS","AS_RGUL","AS_RGUU","AS_RP","GENERAL","NC","RTC","SD"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of instruction type","examples":["Ancillary Services Frequency Control","Ancillary Services Load Shedding","Ancillary Services Rapid Generator Unit Loading","Ancillary Services Rapid Generator Unit Unloading","Ancillary Services Reactive Power","General","Non-Conform","Reserve Trader Contracts","Security/Direction"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1999/04/20 14:56:06"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region id if regional instruction only.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INSTRUCTIONTYPE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":576,"decompressed_size_all_time":765240},"visibility":"Public","trigger":"Ad hoc"},"INTCONTRACT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#496"],"comment":"INTCONTRACT shows intervention contract details. These are specific to each intervention.","description":"INTCONTRACT became unused when Ancillary Services Review was implemented\nin 2001.\n\nConfidential to participant\n\nSource\n\nINTCONTRACT is unused; was updated as required.","unused":true,"primary_keys":["CONTRACTID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Intervention Contract Identifier","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Terminate Date of contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Terminate period of contract in trading interval","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date/time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting Date of Contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Starting period of contract","is_integer":true,"num_int_bits":16},"DEREGISTRATIONDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not Used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEREGISTRATIONPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Not Used","unused":true,"is_integer":true,"num_int_bits":16}},"visibility":"Private"},"INTCONTRACTAMOUNT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#505"],"comment":"INTCONTRACTAMOUNT shows intervention contract amounts.","description":"INTCONTRACTAMOUNT became unused when Ancillary Services Review was\nimplemented in 2001.\n\nConfidential to participant\n\nSource\n\nINTCONTRACTAMOUNT updated with intervention contracts settlement\ncalculations.","unused":true,"primary_keys":["CONTRACTID","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Intervention Contract Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier based on calendar settlement date - YYYYMMDDPP.","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Intervention Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AMOUNT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Intervention Amount for Trading Interval","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Regional Recovery Flag"}},"visibility":"Private","trigger":"When there is contract creation or changes"},"INTCONTRACTAMOUNTTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#514"],"comment":"INTCONTRACTAMOUNTTRK shows the latest valid version of each intervention contract.","description":"INTCONTRACTAMOUNTTRK became unused when Ancillary Services Review was\nimplemented in 2001.\n\nINTCONTRACTAMOUNTTRK is confidential to relevant participant\n\nSource\n\nINTCONTRACTAMOUNTTRK is unused; was updated for contract changes /\ncreation only.","unused":true,"primary_keys":["CONTRACTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Intervention Contract Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Intervention Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date contract was authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When there is contract creation or changes"},"INTERCONNECTOR":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"INTERCONNECTOR","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#37"],"comment":"INTERCONNECTOR sets out valid identifiers for each interconnector.","description":"INTERCONNECTOR is public data, available to all participants.\n\nSource\n\nINTERCONNECTOR changes infrequently, usually annually.","primary_keys":["INTERCONNECTORID"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Id of this interconnector","examples":["N-Q-MNSP1","NSW1-QLD1","NSW1-SA1","SNOWY1","T-V-MNSP1","V-S-MNSP1","V-SA","V-SN","VIC1-NSW1"],"is_categorical":true},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of interconnector","examples":["Basslink DC Interconnector (MNSP)","Directlink DC Interconnection","MurrayLink DC Interconnector (MNSP)","NSW to QLD AC Interconnection - QNI","PEC-MI NSW to SA Interconnector","SNOWY1 TO NSW1","VIC1-NSW1 Interconnection","VICTORIA TO SA","VICTORIA TO SNOWY"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2004/06/11 10:43:05"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONFROM":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Starting region of the interconnect","examples":["NSW1","SNOWY1","TAS1","VIC1"]},"REGIONTO":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Ending region of the interconnect","examples":["NSW1","QLD1","SA1","SNOWY1","VIC1"]},"RSOID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","unused":true,"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERCONNECTOR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":656,"decompressed_size_all_time":830540},"visibility":"Public","trigger":"Usually annually"},"INTERCONNECTORALLOC":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"INTERCONNECTORALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#46"],"comment":"INTERCONNECTORALLOC shows allocations of interconnector residues to Network Service Providers.","description":"INTERCONNECTORALLOC data is confidential to the relevant participant.\n\nSource\n\nINTERCONNECTORALLOC changes infrequently, typically annually.","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","PARTICIPANTID","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date of Allocation Details","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version No in respect to effective date","is_integer":true,"unsigned_int":true,"num_int_bits":32},"ALLOCATION":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allocation % / 100","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Usually annually"},"INTERCONNECTORCONSTRAINT":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"INTERCONNECTORCONSTRAINT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#55"],"comment":"INTERCONNECTORCONSTRAINT sets out Interconnector limit data used as defaults in dispatch, predispatch and STPASA and used by SPD in calculating flows. INTERCONNECTORCONSTRAINT includes an additional field to restrict an interconnector from support transfer of FCAS.","description":"INTERCONNECTORCONSTRAINT is public data, available to all participants.\n\nSource\n\nINTERCONNECTORCONSTRAINT changes infrequently, typically annually.","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date that this limit is effective from","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Id of this interconnector","examples":["N-Q-MNSP1","NSW1-QLD1","NSW1-SA1","SNOWY1","T-V-MNSP1","V-S-MNSP1","V-SA","V-SN","VIC1-NSW1"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version for this date","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["BATCH","CASSA","CBROWNLEE","CBRUCE","DENNISG","DGRAHAM","GARRYL","GAURAVS","GLANDERS","Huajie","JEFFP","LHOWARTH","LUKEB","MARIAH","MARKS","MCORBETT","PJH","RGARROWAY","RGILLETT","RHARVEY","SANGEETAP","SBONINI","SGNANASKANDA","SVOCISANO","TERRYH","TOM","Tom","ZOE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["1999/07/24 23:55:07"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EMSMEASURAND":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Identifies the EMS entity that represents the interconnector flow","examples":["BLGC.LINE.BASSLINK","BLGC.LINE.GT_GC_MARKET","BURONGA.SUMM.BURONGA_BUNDEY","DUMARESQ.SUMM.DUMARESQ_BULLI","HYTS.SUMM.HYTS_SESS","MLNK_B.LINE.MURRAYLINK.MW","MULLUMB.LINE.DIRECTLINK","NSW1.SUMM.NSW1_SNOWY1","SNOWY1.LOAD.VIC1","S_EAST.SUMM.HEYWOOD","S_EAST.SUMM.HYTS_S_EAST","T174_TRA.SUMM.MUGBA_TRA","TO.BE.ADVISED","VIC1.SUMM.VIC1_NSW1","VIC1.SUMM.VNI"]},"EXPORTLIMIT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Interconnector export limit","examples":["200","3812"],"tips":["This refers to the maximum permissible flow north or west."],"is_integer":true,"num_int_bits":32},"FCASSUPPORTUNAVAILABLE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate that the interconnector cannot support FCAS Transfers","examples":["0","1"],"is_boolean":true},"FROMREGIONLOSSSHARE":{"sql_type":"NUMBER(5,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Loss share attributable to from region","examples":["0.05","0","1","0.91"],"is_float":true},"ICTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"REGULATED\", \"MNSP\"])","mandatory":false,"comment":"Interconnector type - Currently either \"REGULATED\" or \"MNSP\"","examples":null,"enums":["REGULATED","MNSP"]},"IMPORTLIMIT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Interconnector import limit","examples":["0","200","2540"],"tips":["This refers to the maximum permissible flow south or east."],"is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2003/11/25 15:41:18"],"parse_csv_as_string":true,"is_s_datetime":true},"LOSSCONSTANT":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Constant Loss factor","examples":["0.8105","1.152"],"is_float":true},"LOSSFLOWCOEFFICIENT":{"sql_type":"NUMBER(27,17)","pl_type":"pl.Float64","mandatory":false,"comment":"Linear coefficient of loss factor calculation","examples":["0.000076672","1.152"],"is_float":true},"MAXMWIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit of energy flowing into the RegionFrom","examples":["201","2541"],"is_float":true},"MAXMWOUT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Limit of energy flowing out of the Region","examples":["201","3813"],"is_float":true},"NONPHYSICALLOSSFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Factor for non-physical losses rerun","examples":["100","10000"],"is_float":true},"OUTAGEDERATIONFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SPD Factor","is_float":true},"OVERLOADFACTOR6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector overload for 6 sec","is_float":true},"OVERLOADFACTOR60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector overload for 60 sec","is_float":true},"RESERVEOVERALLLOADFACTOR":{"sql_type":"NUMBER(5,2)","pl_type":"pl.Float64","mandatory":false,"comment":"SPD Factor","is_float":true},"DYNAMICRHS":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used","examples":["F"],"unused":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERCONNECTORCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":6273,"decompressed_size_all_time":7328500},"visibility":"Public","warnings":[{"msg":"For more information about interconnector conventions, see [the guide](../../guide/querying.md#interconnectors)\n","level":"tip"},{"msg":"You may want to join this with INTERCONNECTOR joining on key `INTERCONNECTORID`, to add columns `REGIONFROM` and `REGIONTO`.\n","category":"related_tables","level":"tip"}],"trigger":"Usually annually"},"INTERCONNMWFLOW":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"METER_DATA","REPORT_SUB_TYPE":"INTERCONNECTOR","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#523"],"comment":"INTERCONNMWFLOW shows Metered Interconnector flow data. INTERCONNMWFLOW shows the meter data provided by Meter Data Providers to MSATS.\nDespite the name, this view shows metered energy (MWh) and not power flow (MW).","description":"INTERCONNMWFLOW data is public, available to all participants.\n\nSource\n\nINTERCONNMWFLOW updates weekly.\n\nVolume\n\nThe volume depends on number of interconnectors and number of loads\n(versions) from MSATS per settlement run.","unused":true,"primary_keys":["INTERCONNECTORID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Period identifier (half hour period)","examples":["1","48"],"is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date (based on Trading day, not dispatch day - i.e. period 1 ends 00:30)","examples":["2021/04/24 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"Meter Data Version number","examples":["8416"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"EXPORTENERGYVALUE":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Exported Energy value (MWh)","examples":["0.053009","0","341.405188"],"is_float":true},"IMPORTENERGYVALUE":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Imported Energy value (MWh)","examples":["0.711736","0","569.0325"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Record creation timestamp","examples":["2021/05/01 00:13:10"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_INTERCONNMWFLOW_202105010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":5},"compressed_size_per_month":247993,"decompressed_size_all_time":469963350},"visibility":"Public","trigger":"Weekly"},"INTERMITTENT_CLUSTER_AVAIL":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_CLUSTER_AVAIL","VERSION":1},{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_CLUSTER_AVAIL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#17"],"comment":"A submission of expected plant availability for an intermittent generating unit cluster, by Trading Day and Trading Interval.","primary_keys":["CLUSTERID","DUID","OFFERDATETIME","PERIODID","TRADINGDATE"],"columns":{"CLUSTERID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Cluster Identifier for this cluster within the DUID","examples":["BALDHWF_C1","BANGOWF1C1","BANGOWF1C2","BANGOWF1C3","BANGOWF2C1","BANGOWF2C2"]},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["BALDHWF1","BANGOWF1","BANGOWF2","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this cluster availability submission was loaded","examples":["2026/08/23 20:52:19"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval number (1…48) within this TRADINGDATE for which ELEMENTS_UNAVAILABLE applies","examples":["1","48"],"is_integer":true,"num_int_bits":16},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The trading day to which the availability submission applies","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ELEMENTS_AVAILABLE":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Number of elements within this CLUSTERID (turbines for wind, or inverters for solar) that are available for this TRADINGDATE and PERIODID (scheduled maintenance in AWEFS/ASEFS). Value between 0 and the registered Number of Cluster Elements. Value = 0 means no elements available","examples":["6","52"],"is_integer":true,"num_int_bits":32},"ELEMENTS_UNAVAILABLE":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Number of elements within this CLUSTERID (turbines for wind, or inverters for solar) that are not available for this TRADINGDATE and PERIODID (scheduled maintenance in AWEFS/ASEFS). Value between 0 and the registered Number of Cluster Elements.Value = 0 means no elements unavailable","examples":["0","1","3"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_CLUSTER_AVAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17487690,"decompressed_size_all_time":1944695270},"visibility":"Private & Public Next-Day","trigger":"On participant data submission"},"INTERMITTENT_CLUSTER_AVAIL_DAY":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_CLUSTER_AVAIL_DAY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#23"],"comment":"Summary record for an availability submission for an intermittent generating unit cluster for a Trading Day.","primary_keys":["CLUSTERID","DUID","OFFERDATETIME","TRADINGDATE"],"columns":{"CLUSTERID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Cluster Identifier for this cluster within the DUID","examples":["BALDHWF_C1","BANGOWF1C1","BANGOWF1C2","BANGOWF1C3","BANGOWF2C1","BANGOWF2C2","BERYLSF1C1","BLUFF1_C1","BNGSF1_CL1","BNGSF2_CL1","BOCOWF1_C1","BOCOWF1_C2","BOMENSF1C1","BOMENSF1C2","BOMENSF1C3","BOMENSF1C4","BOMENSF1C5","BOMENSF1C6","BOMENSF1C7","BOMENSF1C8","BOWWPV1C1","BRDDSF01C1","BROKENH_C1","BRYB1WF1C1","BULGANA1C1","CATHROC_C1","CHALLHW_C1","CHILDSF1C1","CHYTWF1C1","CLRKCWF1C1","CLRKCWF1C2","CLRKCWF1C3","CLRKCWF1C4","CLRKCWF2C1","CLRKCWF2C2","CNUNDAW_C1","COHUNSF1C1","COOPGWF1C1","COOPGWF1C2","COOPGWF1C3","COOPGWF1C4","COOPGWF1C5","CROOKWF2C1","CRURWF1C1","CRURWF1C2","CRURWF1C3","CRURWF1C4","CTHLWF1C1","CTHLWF1C2","DAYDSF1_C1","DAYDSF1_C2","DUNDWF1C1","DUNDWF2C1","DUNDWF3C1","ELAINWF1C1","FLYCRKWFC1","FLYCRKWFC2","FLYCRKWFC3","GANGARR1C1","GIRGSFC1","GNNDHSF1C1","GNNDHSF1C2","GNNDHSF1C3","GNNDHSF1C4","GOESF1C1","GOESF1C2","GOESF1C3","GOESF1C4","GOESF1C5","GOONSF1C1","GPWFWST2C1","GRWF1_C1","GRWF1_C2","GRWF1_C3","GULLRWF2C1","GUN_C1","GUN_C2"]},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["BALDHWF1","BANGOWF1","BANGOWF2","BERYLSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BOMENSF1","BOWWPV1","BRDDSF01","BROKENH1","BRYB1WF1","BULGANA1","CATHROCK","CHALLHWF","CHILDSF1","CHYTWF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COOPGWF1","CROOKWF2","CRURWF1","CTHLWF1","DAYDSF1","DUNDWF1","DUNDWF2","DUNDWF3","ELAINWF1","FLYCRKWF","GANGARR1","GIRGSF","GNNDHSF1","GOESF1","GOONSF1","GPWFWST2","GULLRWF1","GULLRWF2","GUNNING1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this cluster availability submission was loaded","examples":["2025/10/02 22:44:40"],"parse_csv_as_string":true,"is_s_datetime":true},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trading Day for which this cluster availability submission applies","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_CLUSTER_AVAIL_DAY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":518758,"decompressed_size_all_time":63595870},"visibility":"Private & Public Next-Day","trigger":"On participant data submission"},"INTERMITTENT_DS_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_DS_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#29"],"comment":"Unconstrained Intermittent Generation Forecasts (UIGF) for Dispatch","primary_keys":["DUID","FORECAST_PRIORITY","INTERVAL_DATETIME","OFFERDATETIME","ORIGIN","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"DUID (or Area for non-scheduled) where this forecast applies","examples":["ADPPV1","ALDGASF1","ARWF1","AVLSF1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BERYLSF1","BLUEGSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOMENSF1","BOWWPV1","BRDDSF01","BROKENH1","BRYB1WF1","BRYB2WF2","BULGANA1","BUSF1","CATHROCK","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DARLSF1","DAYDSF1","DDSF1","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","ELAINWF1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Unsuppressed forecasts with higher priority values are used in Dispatch in preference to unsuppressed forecasts with lower priority values","examples":["1","436"],"is_integer":true,"num_int_bits":64},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when the forecast applies (dispatch interval ending)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this forecast submission was loaded","examples":["2026/08/31 23:55:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ORIGIN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Origin of this forecast (PARTICIPANTID, AWEFS/ASEFS, or another vendor)","examples":["ALNTARES","ARARATWF","AWEFS_ASEFS","BERBANKW","BOCOROCK","BODWF1","BOMENSF","BULGANA","BUNGALA1","BUNGALA2","BUSF","CLARESF1","CLEMGPWF","CLERMSF","COLEAMSF","COLLECWF","COOPGWF","COROWASF","CROWLDWF","CSF1","DARLSF","DAYDSF","DUNDWF","EDENVALE","ENELAUS","FSNSW","LALLALWF","NEWGEN","WILDCATL"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when the forecast applies (dispatch interval ending)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_MEAN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast MW value for this interval_DateTime","examples":["0.725","0","82","84"],"is_float":true},"FORECAST_POE10":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 10% POE MW value for this interval_DateTime","is_float":true},"FORECAST_POE50":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 50% POE MW value for this interval_DateTime. Used in Dispatch.","examples":["0.000001","0","82","84"],"is_float":true},"FORECAST_POE90":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 90% POE MW value for this interval_DateTime","is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_DS_PRED%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":246188516,"decompressed_size_all_time":51877356030},"visibility":"Private & Public Next-Day","trigger":"Publication of Dispatch solution. Data includes all valid forecasts for that interval"},"INTERMITTENT_DS_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_DS_RUN","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"NONE"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#35"],"comment":"Unconstrained Intermittent Generation Forecasts (UIGF) for Dispatch.","primary_keys":["DUID","FORECAST_PRIORITY","OFFERDATETIME","ORIGIN","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"DUID (or Area for non-scheduled) where this forecast applies","examples":["ADPPV1","ALDGASF1","ARWF1","AVLSF1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BERYLSF1","BLUEGSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOMENSF1","BOWWPV1","BRDDSF01","BROKENH1","BRYB1WF1","BRYB2WF2","BULGANA1","BUSF1","CATHROCK","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DARLSF1","DAYDSF1","DDSF1","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","ELAINWF1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Unsuppressed forecasts with higher priority values are used in Dispatch in preference to unsuppressed forecasts with lower priority values.","examples":["1","436"],"is_integer":true,"num_int_bits":64},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this forecast submission was loaded.","examples":["2026/08/31 23:55:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ORIGIN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Origin of this forecast (PARTICIPANTID, AWEFS/ASEFS, or another vendor)","examples":["ALNTARES","ARARATWF","AWEFS_ASEFS","BERBANKW","BOCOROCK","BODWF1","BOMENSF","BULGANA","BUNGALA1","BUNGALA2","BUSF","CLARESF1","CLEMGPWF","CLERMSF","COLEAMSF","COLLECWF","COOPGWF","COROWASF","CROWLDWF","CSF1","DARLSF","DAYDSF","DUNDWF","EDENVALE","ENELAUS","FSNSW","LALLALWF","NEWGEN","WILDCATL"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time where the forecast applies (dispatch interval ending)","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Authorising officer of this forecast (applicable for participant forecasts only). This column is not made available to the public."},"COMMENTS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast. This column is not made available to the public."},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed.","examples":["2026/08/31 23:55:01"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata relating to the forecast. This column is not made available to the public."},"PARTICIPANT_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Participant can document when the forecast was created","examples":["2026/08/31 23:55:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SUPPRESSED_AEMO":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Was this forecast suppressed by AEMO? Suppressed = 1,Not suppressed =0","examples":["0","1"],"is_integer":true,"num_int_bits":8},"SUPPRESSED_PARTICIPANT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Was this forecast suppressed by the participant? Suppressed submissions may not be used, Suppressed = 1, Not suppressed =0","examples":["0","1"],"is_integer":true,"num_int_bits":8},"TRANSACTION_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Uniquely identifies this interaction","examples":["00ac6a4a-e30e-4480-b655-353ba8a8984e","00d462c2-1966-4bb5-bf5f-3d8b9b6e2c9d","01977b93-5f42-46a9-bf78-55636d1a7cb8","019b7398-e968-45d4-b648-0991919500c8","01efd97a-aef3-4807-8a7c-a61df5f9ce7f","023dff65-ef34-44fa-8747-b6356b18e535","02988117-6889-4c45-a156-aa2de0aafa6a","02bee6e9-de6f-421b-96b4-4fb9df827af7","02e2f7a1-fee2-4d31-be4d-d1394a476e8d","03060384-4343-40a6-a3b4-336a423871a6","03bee053-7f0c-403f-85aa-e881765ef145","03c4c40e-c2ca-4578-aa67-36b978f812b9","03cc7f37-2ad9-4858-867d-4467eaa2cca2","0469ac3b-f69b-4c00-8d58-cdaf0b611a51","04a1f554-f1a3-456e-8a92-0062d3d1b8d3","05669a22-c4a6-4bbe-a9b2-7acad4181a4f","057a3321-42da-4fa7-bb8d-8bf34cfb77f6","05d34a30-127d-44b5-8ea8-da460078244b","06006cf5-ad3f-4117-a72d-1a81697d510f","06037d1a-5c06-4c11-9c55-269c2e70db8e","065462a1-e163-43a1-9967-f81bda95a0b9","06bca0a7-f6a0-4cd8-8082-49344f51a07e","07246827-faa9-427f-b39d-bc1d602b093b","07267aa0-59d2-4867-a413-2a00f5bee3c2","07b91956-9bbc-4bda-baa6-fa7af8b307dc","0817066d-f254-4abe-9b8c-b1481db53f6a","0820210c-c8c7-4104-abb4-5e6af3818cf7","082680f7-9192-42d0-bf78-4f3cd6258f59","0836453d-4feb-43a9-bc15-bebad8cb1d39","0840ce00-33d0-47c4-9b67-a87936359674","0843700b-6324-4cbd-a421-bb63f8faa0f4","0848874b-f685-45dd-8e82-629c35b6226e","08a0cf2f-5463-428a-aab9-d8eb10e4f439","0964c540-f599-4a80-a6b2-7a1b5bdcbf47","09a58cee-0eb8-46fe-9bcb-80eb9999cdee","09ca53c8-7bb6-4230-8058-f364f4b9f7d8","09f7a3a1-0b6e-4a97-9905-e504731adbba","0abbc68e-4814-4d2a-b0a3-2c4b7ed78479","0acd2bb3-9a76-4390-860b-17b940ab8d1d","0add491b-1407-40eb-9a13-1ffa99bc195a","0b079206-9924-4012-9677-a56527ad16af","0b0d3f07-643c-4785-b2f2-822118fbf9ad","0b57bbc5-7c0c-4949-b8b0-073b2d5d6fdf","0b92271b-e739-418c-8664-ea3bccaed30f","0bea06ce-bad4-40f4-ac66-c1ff6ba29a1b","0c4544c2-9a1a-40ed-8ed6-a75740120de5","0c7ddece-14f3-4780-bca0-ccc35e786625","0ca91946-dd32-46b1-ba46-c2c18e19dadc","0d194b8f-9c00-4579-be4c-7d6e88cbd5ca","0d54612e-ce24-4dc8-8d5b-7aef9354b144","0dd8cf63-d17f-4f2a-937f-873c058e10cd","0e0cb06b-a5ab-450c-8d8e-e42f63e4071d","0e48b805-c07c-4f30-aaf4-e16b4f95f964","0e69fba3-2779-4d78-a12b-aba7ded0f788","0fa93811-4390-4fcc-a44b-04a37d94aafe","0fb0bbcf-0bb0-4350-9ef0-744a3fceed75","10151642-cba8-4884-9ede-6744f16b8c82","1083d9b3-a094-40d2-876a-84e3afeed8e8","10b4fe31-9943-41b9-91f6-2e8f09b6d8b1","10bd61f7-b2f6-4fc1-9ea4-58016b7fb315","10e9e913-cab7-4997-9c2e-c7a74807bbc2","111e5793-bf18-4567-958f-21473a855b6c","1134e106-7078-4873-8164-246c10a58929","11d69b31-087e-4554-a5db-143fc7da919d","11ee48ea-4931-47f1-85fc-4854a20ffed4","127a4c81-d606-4bfb-a794-f73c80f89116","128c13ac-44dc-44f8-a4ea-22a494b0b900","13610286-3830-4db7-8412-4d1fe77be6fd","1379fde9-1aa2-4dfb-bb42-665d2a39574e","13d313e7-fb89-41f9-8bc5-87ac35cc6cec","14230ec0-c0dd-4c7a-bb70-0b8eede52917","142831f2-23c4-418c-85e1-2617b87d2c64","1476cebc-b6fb-453b-b601-f31c7039b304","150cbc42-5b39-4eca-9530-c377b0527b7c","15a4856b-1e8b-4627-9a64-b4fff2ac7b1c","16705836-9aac-4d61-a2bf-25571dd632cc","1683a674-379c-4cdf-a2db-4a2edb30e518","169464f4-1abd-424b-b097-52cb151f0d17","16aa711a-7b74-48a6-a00e-0947b1ad7bbc","16b0251c-220b-4f13-ad62-93d055d3a860","16f11e58-8c74-44a5-9283-d2b115fa96aa","1780d2c2-f9ce-4f59-83eb-b8280d8967f0","18239c1d-3735-4627-b3b7-c6ae81d86e08","184cc96d-b0c1-492c-8477-77069505b976","187e46d6-936c-4549-9720-c39988cae1cb","195df8a1-3ccd-4231-89a9-9929731ecabd","196d9df4-f853-46b9-8433-91c78fd14fc1","197d22fa-e8b4-4d36-9f3d-42871aff62c4","198a3bb6-4dd2-445f-922a-241c3f839440","1a5232f4-de5a-4e2b-928d-4c008fe0a41f","1a745e9c-d142-45b1-a34b-832a0a1257f7","1ae379b0-44bd-42ec-8276-0d5dfa752f17","1aeb6059-ae58-4476-980f-483a06dd4e54","1b069622-b94f-4b4c-81c7-3cf2d18d5d73","1b7c6335-0da8-490e-b3ff-8556d0a54eaf","1b8a5b2d-fe25-419b-94f9-2754745e3820","1b9c6006-23e7-4854-aaf9-9920445fdd28","1c1f9e88-3293-451d-b8a9-51c545e39cb4","1c3b1d03-ed3e-4fd9-849c-f944766f2978","1c770ea2-8339-420a-a7fd-e306109069fc","1c8c7b4b-8582-4f2a-93bf-d5ded0e284a4","1ca69114-a4b4-49d8-86f3-3042cb8fcf5b","1cd3255b-8577-4d5e-a0f2-79173e852b56","1cf19c3f-14af-4640-a9c8-47c64969a6b8","1d08c734-0c0b-4899-9c80-50c5016b8cc1","1d358a75-8265-4ab6-8cfc-80f6a8b94fc2","1d53aecc-2cd7-415b-a811-95c90e4cb3e0","1ddb3585-a5c6-4df2-bcca-5e287dc88889","1e0b3e78-8f7c-4e01-b5ab-da722ed1faa2","1e456e7a-c3b9-44e9-9ac4-356410efd45a","1e868337-1a62-4976-8daf-54dcc5a738b6","1f02d47e-24b5-4883-9630-62d539ac4ef1","1f214a6e-fd3b-44c8-bf59-45e44f73578d","1fad7447-26ab-428b-9d2b-bff1daa44513","20152022-f6a2-44a4-8cf9-8ecb60f24985","2061fbb6-8581-4246-9436-4a35dfe3b726","20ac58ac-4308-4301-9929-6a1df3758153","20b5fb13-a3df-47be-831f-f36dcd6ffe96","20d768f4-d631-47ed-b6e2-3e9eb3c4012d","21232d9f-d659-4dcb-b933-4fc4417e6231","213bb756-08e8-403a-b52f-f02953bf07cc","2155521a-fb52-463f-9a35-3ac3d17b77d6","2174f3b3-f6ce-4d1b-9c6a-02f4b17082ac","217f1f00-a47f-4f4d-bb21-17c8ee1ffe21","2222f1d9-7bd5-4078-ab57-70ccdd6e0664","2245b65f-81ad-4312-914e-b5f8b19da4c5","22b9a01c-2540-475e-bda0-95d59996e049","231a4761-01cf-4248-91c8-8f73c7d98561","2342dbab-5343-44c0-86f4-dcc374728e9b","2382d1dc-2027-462d-a920-139e1c893d83","23d8d8e7-e477-4d86-9d2e-28d7d8dee887","24051913-f15d-4c20-ad88-ea141f267128","241e9462-bc61-4535-94cb-b0a8bcf544b8","244348ee-bdab-4961-81bf-69533beec8a7","2474a3e7-da0c-432a-992d-20c8f1f2276a","252567ca-0d7c-43ca-839c-db461f0c7c14","2538c62a-911f-429c-aa92-624c28539d0d","25828fab-aa9a-4ced-9cf0-f2537bc0ab92","2597641c-a7fc-47b5-ba23-16d3f705bb4f","25eb7ac3-771a-4fbf-867f-24fb31f01515","263c5445-5ea5-4a11-9b9d-9b37be3c4ea2","26481caa-46b1-41e4-b80a-4800935468c4","264d1e86-63d2-4ac3-9b2a-fd6ac15313ab","265ac253-dbb8-4708-9e24-c17efce285bf","2669f801-4bb8-4f8f-9a36-0f11fd5bea36","271a03a5-e379-47e7-977c-a8f8c3f94990","27316776-bbf9-48d5-ad91-ee768827fc47","27717452-544b-4bac-8435-82a0ee41c8ed","27768ce8-22dd-4129-97e1-d32a2ff60be1","27d7966a-7bbe-4ed8-9929-4544d27f9da8","27ef04cc-c04c-43d0-95e5-9f08ebb715c7","27fde932-314b-4fc6-a262-e9c7c4eb737a","2878cf3c-8a02-4ab0-aba9-d661b5022ed0","28c002d7-59fe-4295-ac6c-75f9996171b0","290cf468-866f-4a6c-86cd-95d4c845144a","293f1dea-779c-4d04-b649-62edad99ec69","2949a09f-9b62-49ab-9fd0-da86d1d27e91","2950814d-b91d-4daa-9e1c-b0e7bb2074bc","29a8fd0a-8ef2-4d2a-a247-17f65c143c3b","2a00c417-503b-46bb-81b9-a97fb5bc9285","2a5219a1-3fd3-4198-b4d1-1ff40ad90b71","2a5dbcd2-4228-4167-9803-956c2c22eab9","2a69d1fd-3065-40b6-a2a5-4f74c206becc","2ab803e4-98f2-40d3-aae2-e72a87553e29","2ae6a549-3090-4531-ae3c-babfcfcdc703","2af3137a-af15-4e00-a92e-864e99c03ea9","2b0cd1cf-9fe3-4d0e-a28a-96be56180ac4","2b0f29fb-2dd5-4877-a048-2d2dec280509","2b5118c0-b7cc-4a0c-84d4-eaebb54bd1b2","2b5aa541-2050-4ef7-a7f5-3ec450358c33","2b7060ef-24c8-4b00-a911-ebdbef776b4f","2b857571-88d4-4504-8f9a-1f2f7e4cec44","2bc44947-5047-4e23-a14b-5e9cdb86deea","2bf25d50-ff8c-42a5-a67f-a19269cb2b5c","2c383e8f-f9d4-48f3-b087-40238a2d05fa","2c96e7cf-6c23-47e2-af7f-c8fd79e4c762","2ce82c37-daab-4983-acd6-19f9a7f667f2","2d328d38-25dd-4a69-ad92-25b95baecad8","2d45f6ac-3dc9-4c3a-90f0-4a27554aa03b","2d7db0b9-c1ad-4a67-8b29-fefe91cabdf1","2d9ccec6-810f-4fac-860f-350fc306846e","2df2bd04-8272-4483-8110-22d12c69e1aa","2e5dddb7-e138-43b5-b946-dccdedbb282c","2efa8b06-e7a1-4a47-8537-48dc92dec13e","2f0d1dc1-daf9-4f9b-bbe6-02bc18765807","2f310f98-fb3a-4bda-bd1f-8afe2bdf3adf","2f8bdf3a-3291-44d8-b598-b46f1070ea41","2f9c7e03-e59d-4b57-b886-a8b48d43c9cd","2fcf9063-f3cb-48d3-bc57-48463edc2b10","2fe51bc6-9a24-4833-8466-d28fa94d845b","2ff68137-bbd7-4379-8071-b463a663260a","2ffebf8a-d057-46f0-b03d-c79178d691fe","3002420e-6407-45de-abf6-f21e72b61eb3","3041c5ee-2d75-447a-8ae0-05191dbb4039","306c8606-07e1-4067-920d-c385eb3e5181","307fb89c-1343-4569-a90f-6560d54ed5d7","309271b7-9709-4cee-b6f9-837bcd5f1ca2","310f939a-69ff-4a83-b863-e9c4bc4e45c6","31cfc838-eb2a-41b3-8161-cb9f36b47e28","32ea1adf-840a-4a8d-a059-aaa9573bc43b","32fb9f6f-7898-4da3-9836-1e12196204df","330739a2-3604-48e8-b33c-26d19b2cb829","330e8bf3-51c0-4b5e-aefe-8cd3267937d9","333ddeec-a899-44b1-b146-c86dc60000cb","33c0dc00-5513-4560-a69a-220a47edfaee","33f9dece-8272-4464-bf65-7b1aab0e75a8","3498fd84-33b9-4352-8c62-7ed797dfe39f","35dafa0e-dda2-492c-a29e-16034685759d","3601afb9-a159-41f0-b8fc-30ce3c424a6d","365daa11-1e14-4dfb-8c31-c2789ce0378e","366fb2f8-42b6-4f71-8a97-ebdb0d991015","367699a1-affb-4834-b1da-4f06bef2a7d9","36b4f5d8-397a-4a9a-b531-499afbc1d1f7","36fde4e6-b939-40ac-98ec-a4b87cba8a68","3703c244-fa20-4c28-babc-bb70b4cfe3ca","37bd2581-85ea-4f40-ab3e-be5c28305ac7","38201102-6b86-455f-abb4-69d3d1b5dcf6","38edffc5-bad6-4c1c-8971-4d792b106baa","393d794b-c66d-4c8d-b4c3-65d1d6262f98","393e70f5-6f49-442a-8b5b-8d24dc792cc7","398142ef-998a-49b7-ad22-f99d757d5f77","39857bd9-7135-4077-a674-a7589af0d8bf","3a0916a6-1531-4c8a-91bf-cce32f4daace","3a3587c7-a97e-4441-bf3e-9bf638d36db9","3a43f127-7b7d-4193-8121-a152fc1440fc","3a735b89-640b-429d-a436-df6d9030ad47","3af4dc41-0543-44b6-b0ea-a71296b7c25e","3b4a5dab-aaea-40f8-b41f-2b579080930e","3b72d0b5-9b2f-4271-94ab-d892707b83a9","3b86fe9b-2615-4847-bded-25b4af1d70b5","3bc5790a-20e2-4d25-b6c0-8adbe89b95ff","3c0e2bf8-06de-4c9b-abfc-6a837af4b2dd","3d0cc53b-5e08-4004-abb2-7e580db1e275","3d99059f-f5b6-4a8c-8c15-b052bd9770e9","3dba64fb-4b6b-47c5-8944-5139a4942f80","3df3c40c-3494-4255-8d26-47691bf7a65a","3e643c5d-a010-4129-81e5-95e2d8d35465","3e8a5041-8990-4131-b109-116c3a8adc0f","3f20e28c-838e-437f-9cd8-2c713fd3a118","3f43578c-0afb-41c1-add6-9193de61367c","3f80c0d9-e475-4da8-a5eb-8b12bb11333c","3f8da04c-53ad-4651-b37c-eed72dccbb31","3f94ca6b-1442-4587-9b07-9cd723704748","3fae968d-98c3-4903-b255-71e676e8741c","3fd7ee53-59d2-4c5e-ab5d-5ab190a9db3e","401c322f-b183-4a27-852b-fbbf971e3177","4067edcc-cc51-4a54-aff2-7784121ff2b4","409df10e-6928-49da-ab9b-19e513570492","40b773e1-ed72-4c3e-b717-1bb11de8fbe5","40c8c78d-db47-4cb8-b2f6-f35758564bb7","410513b7-32f7-471e-b878-b76fbc855a2a","411355b5-5c83-413a-bb86-c88964df1710","412a5517-2b14-47db-881d-4af504492e6e","415d6eab-e638-4e87-a05f-ed65ec54afbb","41b8493c-ed03-4636-8ad0-3210e317680c","41bbd732-7c01-434a-a846-322a407d6283","41c4aa97-d577-4218-8fa7-04ed40be837e","41eb9546-c676-419e-9b0c-5109006406f7","41f00b8b-a573-4026-9546-d52beeeb0b19","41fc4865-41b4-409a-a17e-15463f8fc35b","42903fb1-4913-48cf-b7b5-1149b3f3771c","429848b9-b9eb-4fa6-b48f-81173bf46ca9","42c4d1e1-882d-4728-b0cc-55a64fd25b2a","42e4b922-028e-4c34-b380-f180223b74f8","42f07c04-9604-4bc2-b6c7-9b59f3d9a8ee","4336322b-0512-4a32-8ce7-ec1d5153e30d","44936154-3738-4488-b7c9-2555f7b37889","44b8b6ed-9384-4aaa-b1b2-3b396bed5612","44d59ac6-1172-494e-886d-4dd81d08a425","453c7aef-68e0-4ce9-ae5f-0eafbe4a9a62","453cb346-111f-47b5-9071-d62b619f6149","461e20c9-d6a9-4a2e-b89c-f4560369430a","4644dc08-204b-4006-b72b-d067d966f8b7","4668178f-da98-466d-bdf9-c4973247e8c6","46aad9d0-4d3d-44dc-bf3e-185a51a745c1","46ec2a57-a3ff-4e2b-8263-d039a6d550d4","4711ffea-247d-41c3-b076-127553cb013b","476197b0-52e1-47b9-a7a3-99d03b617f12","4781cd95-a759-4e8b-be63-2ae9dccfc0a6","47b414a7-e04d-4522-8da5-2ce4d0135b06","47bb6a91-d9a5-40da-899c-c4ba6094f978","47d38d47-0df1-4a59-ac59-9e7099e3f181","48236895-8700-461a-bc0d-e8a65c50c6d1","487dbe26-3ae4-40f1-9db7-c02c3a8c0c4f","48b8201f-c356-4fde-9f7f-56d7a9bb60f8","48c1393f-203a-4d31-8dd2-74093888803b","48c58b0a-9185-4fa8-bd5e-ff913e9cf9a7","48d63222-1279-44c8-bd02-1ecba2adcd5d","49299aa6-0809-42cc-a365-cc229fdbfd20","495f635c-d2d1-48fc-944b-72ae19d19ff5","4968e414-4702-4aa2-a639-c29e5b558fa5","49a85803-1b4c-46b0-86c1-376f3f1af645","4a020d8a-f6d5-4219-bb0e-b3cf06228bf1","4a6770c0-20ac-46a6-98b1-e02001588215","4a6d1984-c3c5-4c84-9274-56bc8bc4cf1e","4bab60d9-dcf9-4287-a3b3-7547b96828fc","4ccf4941-8858-4a98-891e-9070d9b111c2","4d17b083-235c-4b0b-83f4-5a344c24e531","4d400f17-75fa-4a41-9d4c-4d2f12509cc9","4dcb30b5-c9a4-48cc-93bb-1334b8c159b1","4e11dad5-3869-4519-95aa-e8ab755a0693","4e24198a-38cd-47ce-9fcd-00c5257cd0e9","4e490c10-dc76-49eb-99d8-5852bcbcfbda","4e4bd938-3b5f-430e-ba6e-7e59b325e943","4e7c448d-6bc6-4191-ad85-2c5d19d2a7aa","4eabdd85-0162-42ac-9340-45040fc9e875","4f4c8674-9ef1-4e13-b468-5d51d00d370f","4f67bba4-4e42-4cf8-a20f-887aabf7e535","4f72390a-f201-49bd-8d7e-d062e6bce5c7","4fa75f97-f4e5-46d6-87ba-6f103918c69a","4fb315f3-6df6-45b9-bee0-f90eca71bf33","4fb4d9a8-794e-4f54-8f78-4ba50eac6af8","4fb6a57f-5a8a-4981-8ea1-d9a8e84548f1","4fc20a50-344b-4d6f-9231-7986fbefbe76","4fcd70a1-1a40-4ad4-93e8-2c4a0af38295","4fe23b92-43b7-4c83-badf-2133c14ff048","50b31246-646a-4091-b31d-b804d89b1f7a","513e69c8-21f4-42a8-b698-f4a5dbb32673","519aaa31-364f-4019-9c99-be69a732d395","51a28862-b114-486e-b644-27afda1b5a37","51d18383-a949-491a-8166-591b32eff0c4","51dfd7f7-b892-4436-b3af-1a3278d2aa25","51e17c2b-c773-44f2-89d0-0eac4882b1e2","5207bac8-34ea-4741-b409-893b6b630e84","52104d5d-5951-4878-bde1-d844bd73c4c9","52bf2eae-d349-48ee-a446-22f1b5df3a77","52d6d467-4065-47b4-953c-b8920a377bdd","52f6d2ca-41a0-4103-9fce-9a44d6916aaf","5314d3db-3f3b-41a2-a40c-9372e5c4c85f","5344a734-496c-4529-9524-ce62aa223dea","534e96ac-19d5-48dd-895a-b4da40cf318a","53bd51fa-011d-4878-b4ee-ead31fff9241","53cb99a0-561c-4110-93cb-2c82a31cf57b","54330e2c-43bd-41ce-b699-97fb52f26287","5450449e-4f4b-40c4-9021-d67792968a0c","54c52db7-e856-4dee-9f94-8da646732f03","54eebb60-e78c-4089-84d3-793fc16658a3","55386af7-f324-4569-91d6-498c366a2bff","5549daa6-b5fd-4ba1-9461-6078279fc548","55ad836c-9e9e-49c7-b958-cab0d94c55b9","573f3820-674c-4628-a229-eaca68cbaed5","57cf34d5-eca7-415b-9294-6af9220c062e","585c18ea-cc59-4ef9-987a-11f9ced9321a","587d4116-ebe5-453b-9660-95bf4452fd19","58e5f0fb-6f83-46e3-ad7e-96155b7b8456","59826b8c-da4e-4143-978f-46a2ebab60eb","59cdc204-8f5c-4793-8e99-d6e26ebb6680","59ceda4d-44f1-4eef-94cb-85da0b5231c9","5a15001d-0ada-40d9-b360-80ec9bed882f","5a33d24c-3e2e-4a07-86d7-cb7b33f37cef","5a41f210-126d-4a09-a76b-8bebc0a53dc3","5a568b14-ab36-4982-a1c3-1b6d0fabac43","5a8a46a6-ff40-4626-9e47-796e73f11cd1","5b1b3e2f-477a-4dde-a3e0-40eabdf6a47a","5b3529be-9bfb-45f5-b57d-598d4400baa0","5ba44e45-59a9-4568-850c-cb30eb9020fe","5bfac0da-f500-4b22-a64a-19231a608f04","5c282a0d-4a03-49e5-acf0-2d487ca0b102","5c2a8105-642c-429b-8aab-b8107512ebbe","5c9e1d73-636c-4d3f-99fe-428bd20f7879","5cb663fc-1399-4e0a-9023-f692ed9c35e9","5cdbf312-0336-469e-8f5d-9a2ba7f01b1d","5d00c96c-51fc-4627-bdc0-c940c87ab9d5","5d09ef52-d14a-400c-9789-493f5aa67204","5d1f6106-4819-4019-9e2b-8f1b038ff1f0","5d232ca9-2968-44af-b6b2-e84ce9ca3f1b","5da48471-9b0b-441c-b667-bfa4fea87578","5dbd341f-a427-4b40-b09d-b5dd0658f165","5e01a291-1684-4874-be65-14729f771bf4","5e4a446e-5fed-40b4-875d-87ce5bbd7662","5e4fc4c0-33c7-4315-9f00-1accb76af648","5e736cfc-1e6a-471b-919e-7f1161285cd9","5f31df51-1e08-4cf3-bc60-d77066dc9416","5f35140f-affc-428d-a5eb-c89fa5ef8297","600ef60f-f794-4431-a678-a5982ba4d0b6","60949e88-f132-4a2f-a49b-8125876ee540","619fffa5-8a14-4cfd-bcb4-f93236b9e5a2","61c66fc7-b3cf-47b6-bdee-db7f3620abb4","61cdcbe8-bd66-43c0-9116-418a56bd26a6","61f44436-a34d-47cc-88c0-007d69513dbc","620d5172-4d66-488d-a539-bed4476a55a7","62841853-8c4f-4aab-b2bc-309336aaf983","62d8197f-8a2c-4f52-a9e5-b194d39e60d7","630996bf-29f8-40b7-b998-d2a6d16d7eee","6357db0b-4639-4bab-bc49-eeb3218004de","6392e4c9-709f-473c-a545-9dc225ccabf6","63d3174c-89bf-4748-9524-14497277574a","64238263-4d9c-4b7e-b010-b9160164c0c3","64520ccc-cac0-4a0d-b9ce-9dafb8620b62","6502ea00-827a-4c8f-8856-6eca385720f0","6515602e-8079-43d4-8ad5-ca374b899347","6537bb68-0594-4a8e-b27d-b5b6352f7403","655e89a9-f770-46bf-9bc0-fae898beb1e6","6664a038-dad0-42a3-a431-35e7e1766dd8","66e3623f-2f08-4457-b26b-410e5e3e68ce","66fdd3f7-a0f5-4107-9f80-a45c559fb51a","670542d3-6951-4176-b770-99da9f31aed2","6745f594-4695-4072-a220-dfd035c6f2ce","674d0a96-b165-4577-a727-0f615daac24c","677e6b84-5241-4344-bff4-ef4c26f2d267","679a16f9-4b38-4fd6-84a5-97fc2c5c05aa","67a672dd-eac0-478a-87f5-8e16807a20a0","67e54d75-89a6-43bf-a64a-19b52dd5428d","67eb029b-617b-4a45-a747-c19340879977","67ec80ca-7bb5-42d8-b0f9-85128426c6f3","68f17111-2f95-40a9-9d94-3ac01a452604","69655ac8-d361-4991-8e0e-55d90510f0c0","697e423c-6e73-4ad1-8567-82fb6e7de31b","69a5954b-b60f-4686-83fe-d1804446fc82","69d2280e-84ee-4aa8-8bdb-789349f1b3e1","6a0d0515-beea-4c6a-bc2f-694f363c0b22","6a726781-2b3b-4c60-940c-e0a42e5533fa","6a870162-9614-4ad6-ac01-35a958e29e6a","6a9e4b90-791b-49b4-8c9b-f34683c38dc4","6ac79377-705d-447b-82bd-06503053eab7","6b4435ff-c498-4ca5-b89d-84b83b8a2071","6b665baf-02ed-4856-8041-a15c02a1dfa5","6b6e3806-2282-414e-b6b8-e16a1a66f739","6bbdc9f3-bd0e-4c33-864a-e833cdda6de5","6bcd06f6-b337-4af1-aff4-4b3909d1ece9","6bdae474-103b-4982-923c-4491b69e21cd","6bf3c241-eeb4-46e8-894e-db3760452a4f","6c1bdf99-f457-412f-b8b0-4851f3af119b","6c76d9e1-1f35-432f-ade7-7652ddb9f717","6c77133f-334b-4bb7-aab4-a2301e2db440","6c7e775a-6f0a-420e-bc66-46da1408cbf4","6d02e891-b44a-492a-9cf9-d912bf66764d","6d102a71-6f8f-4c18-b0e6-bc6edfb623e1","6d4081ce-d9db-4458-9247-4ff46c3fdb1b","6d6036f2-0d8f-481b-8ab1-11035adbbe53","6da28a46-ab29-4571-b725-7eb5ade2b0e1","6dddd524-24e3-4671-a96d-3c742b6ff891","6e9e1079-0a34-41d1-991e-3d35f6e5ba5d","6ea0a250-9bd8-400b-8d0a-0e24a204a6ce","6ed1e9f6-0b8d-45ba-a654-fcfcce069370","6f07d2c0-4932-4ea9-8715-bdfe29be1440","700a7930-d3e0-4023-a89d-987883404ffe","70160fff-b92f-49ea-84eb-57412d9a8fb2","7018c9d2-b83c-4b20-ab87-488c7f24c89d","7044a52f-8184-4a43-af68-81b0218e8244","705f0d5a-e655-40f8-bd94-1e39f81433c1","708d8cca-316c-40d5-a41b-80cca9592b94","708e246e-3c15-427e-8e99-e715321cc91d","709243e2-eb22-459b-ae53-358d89120a9e","70e53dd4-e6a0-42d6-b77c-497faacbe230","710aa2cf-3023-4185-a00d-68ebbf7b734f","7159f71f-8585-4f57-a9cb-fcd6f150bfeb","729032dc-5cd6-4a53-871f-fc0e07c700d4","72d32d41-e4c1-483f-8ea8-3f4e7423c09f","73158ddd-c6c5-4a9a-b023-a4e9f40a1daa","73267c19-e56a-453b-9fb0-61704f63279c","7379bc03-8380-4e9a-a927-1fcf634e5bcf","7400c14e-5f65-479f-ad1c-0ea554f59e34","7434d40f-c578-4317-a208-4afedfb277ca","74a7b7b9-4ed0-45cf-8d1a-b2d0495d32d3","74c0898e-a0d7-41b8-8fc5-f9a63292c91f","74cef8ac-8c3e-4af0-b413-bcc1ef433cd9","74ebfad4-973e-49e2-ae32-d63c422bc7d8","74f7b07d-f61e-4ab5-845c-5412941fef26","75055d7e-c3b1-42e0-8007-adcf71e8d7ba","750b62f9-e32f-4149-a771-df9af5aa91c0","75104e76-b83a-417c-9b4a-01492188e6b2","751afd12-ac7f-45d3-8527-3996a2f856e3","7587d25d-a162-425a-bd46-46c11c396ac0","75a51f84-368e-4f91-a2d2-a612ffb4585f","75b2ec68-8e95-41dc-a40e-b6528a1ec82c","75b4c072-3253-4ab1-92be-3cc7b2fdf405","75d150f3-427e-453c-adcd-23df37f9ed93","76766c06-f765-47a6-be09-f92f9ec4c10b","768c8e7c-a8b4-4c83-bef2-30313e273dec","76a01837-5bc1-445f-8863-b3abaccc506b","76d5bdea-07ec-4d02-9bb9-7da7a9de7cc6","76f3ad09-7907-41ea-bc2b-7d6e089766c3","77f1d9cf-6c60-40fb-bf91-2d994b200083","78d70e9c-a3b0-472d-91d3-052809c272ca","79242960-ffdd-4852-9ff9-8a5905ae8054","79432b16-9c40-40d9-bc18-cd8a5ca04434","794843fd-4186-44ea-a526-16f6023e7591","7a24d6fe-74bf-4788-be8d-0409345e4c8e","7a6fa720-b66a-42f1-b157-2bb48b27bfb5","7ace147f-9b8b-4042-9f9d-45831cb69aa8","7b1dbbd4-7eeb-41f6-9806-574f1c2c2b7b","7b292d02-3af6-46a7-aca1-c7171b6ec7bf","7b44eb12-b7e0-433f-a41e-825a1dcd1114","7b6992c6-0bf6-42c2-930f-ca2eb8a08b5a","7c4316a3-d126-4344-aaf0-ba221fc8bb2f","7d437520-7b8e-4199-b828-557106265094","7d56d5b3-f486-4b58-8058-d61e3ab161ea","7d89eec9-516c-4180-bc4f-82ce969f4a44","7de090b1-48c0-4d8a-bb94-a98167402668","7e096f56-61a7-4e2b-b0f2-fa05d52741e3","7e4dbb78-2ff1-4770-b911-68dad2d847ee","7e685132-7945-4209-ac21-da7172f7b1c0","7eb65647-e8fb-4cc0-9613-b360d16b267e","7f4fbe92-0fae-47de-9dfb-96eaf84370b5","7f6bbbe1-9a13-454d-816f-08c46e331166","7f9f1df4-1a88-4dfb-ab8b-f2081e8e85d7","7fa1ed03-75f0-44fd-a3d1-6a302d2afceb","7fe8a925-8cc4-427e-b849-4a70a73c4956","80107b3e-caf5-4970-8946-2214d20c939b","801cebd6-32d0-4c8a-b0f0-3ab43d791d28","805e0c51-334c-4d7f-a302-af211100a3c5","807b83ee-ebc2-4827-815d-d6e0a23f3f38","8080a2ad-210c-49e6-82f2-919ae3b8ed77","81273212-555d-48ed-a424-3eb4714b96b2","812ae72d-82fe-4314-b902-66cf8cc3f7d6","813ee695-260d-4af8-9c2e-c7de8d671c02","81402fd8-9ae8-46aa-a6a8-83438cd71cef","81509231-0e70-4d37-960f-df3fec55df5e","81e14b07-865c-4b01-b547-6bd058bef19f","81e5c682-9757-462c-906d-00a025843e51","81eac564-07a0-4d58-81b0-612b88f4245a","81fc8338-046f-4d0b-8c9b-74e24f9e75cf","826011ce-e252-4fd1-9cac-db2679c07281","8282422e-4812-42a0-9553-25222ae3b41e","82d1a48a-3456-4b63-bb96-fc7a21c47391","82e532aa-9638-4ed1-a61b-700ae867b22a","844c77d6-19b1-43be-82c5-e52b9d86a17f","849b719a-9653-41d2-aee4-2e27aea50ffd","852fe62f-d24d-4205-b228-f676024a84b7","8562752d-a9d1-48bf-bc17-efe28b1ad295","856d2daa-2da7-413c-9184-1f552e46cf5b","85984728-b39e-4d15-9b18-7d4213abbcd5","865f6838-1b6f-4ebb-adfc-c5bdd43cda67","869fbcba-88d5-4fe8-a4d6-8fe51aae9aaf","86da5dce-1b09-439e-8748-d572dbe0ad00","86f8b798-0591-41c9-9031-3571931928d0","882c8d76-9375-477b-bb4a-c83a434e595c","884c2caf-c1e1-4ef8-9b2e-18be37a1ef6b","8892f14b-9db1-4ca6-b2d3-ff5745d5d576","88bad2b3-4a17-4280-a776-b7ddfb865431","88c543d7-85e8-48ce-9728-5a62f9299442","88d3193a-a8cc-4451-8e1e-7e4e53cf69e1","894cba05-7798-4540-a969-7362f44af4b6","8952bc0b-a07a-4ef3-8717-7d82fd440be8","89646373-7a3f-40c9-82c5-aa15bbed066e","89ac116b-40c3-4cdc-a953-7c782aa48308","89e13c9a-bf15-418d-918a-1693fa5b7193","89e145aa-1eab-4c6d-b71c-ffddef30fdf1","89e2a2ab-1a94-48c2-8cdd-fe3dd258e563","8a323618-dd28-4f1a-bb8e-c667c359e50a","8a92a434-0c4f-4e04-8ece-33817f23a594","8aac0be1-6001-41e0-b076-297db36b71af","8ac4b974-7abe-4814-8181-89d03e2ca329","8b628cdc-88c9-45ed-827a-fa1b174bc673","8b9b9d3f-d9c8-4848-a3b7-2b57941ed238","8ba3528b-2890-4846-85df-cb53b0484100","8bac2440-9f3b-4dba-9c75-a0d82cbb9366","8bf64978-7779-4c1c-9d7a-192860668891","8c073069-0d14-4bad-a087-48cadd049fa7","8c2cf779-257e-465b-995a-1756bec054a0","8c387acc-1ea3-493d-ac4a-f97cfdfe6b64","8cd20a21-910e-436b-b204-692c39a0d2fa","8d573f4c-ba1e-4824-9347-a8c944d20390","8d7a2bbc-7be8-4d9c-84a9-d115d048c351","8d8f519a-005c-40b0-80c3-2da9c3f3ef04","8dbc1eb6-9b4f-42cb-a017-9f157d0a01d6","8dbe86ff-5e65-492a-a985-6f9262206a56","8def63d8-5537-4644-9d17-7494c96ab007","8e10c9cd-d3ba-45c4-a9b8-008242b1d199","8eb66a2c-a300-407a-b385-6e74f23f9bc6","8ee6e2be-7470-47ec-91cc-48275da7f96d","8f1344eb-e008-4e5f-9d3e-4bee268cf4ac","8f3cf4c9-faf9-4059-bd33-a9d8e0dfdac8","8f586805-d73e-494c-99dc-c974e204659d","8ff15096-7ba0-4394-88d6-da4a599281e5","9008374e-344f-49c1-a9f7-d246732e91b6","90abb8e2-7b55-4a18-b36e-4a366baf947c","90d80f67-d18f-4742-afcd-259bc4e0f4ab","91089fe6-d4fc-463b-968e-d1ab522a3616","919de776-8a65-4621-afa1-513d35050ee1","91aded13-e7ae-463f-8137-77f22bac60d3","930b3146-2ecd-41d4-8818-b70a2c98ac3d","93ad86cb-e921-42b2-b551-05f9671a9576","9436cbbe-2312-43c9-97d5-5805dd850624","9478d459-1424-4649-9260-6e3626e89803","94fe65ed-a8c3-4fc7-8827-e1f2583d7b29","951fe38c-642f-4b6a-81ab-960f31a82ec2","958e8573-177b-4d94-93e8-7e23ccc516f9","95ab4a9f-1e3d-405e-af92-15a7c7f27596","95c65b5e-2993-40c9-bdb4-1ab33f123272","95cd2864-ab68-4e05-8e91-1bcf8a898a08","960efedf-6c62-464b-b95d-71d19d26fb46","961f14f8-19c3-4911-9859-0007469e0238","9635f7b3-5255-4217-b848-f2e6d6a19101","965b036a-08c6-4702-ab07-9b45ee1e2e93","972aba7e-c5aa-4a51-9a20-7120452286b9","9742deb2-d40a-496c-bba2-d8b61e3fc486","97643f75-c442-4ad3-8f40-ce91ccb3dd9e","978b1c98-da39-49ad-bb44-47e2e165766f","97e9b416-df2b-4f4c-969d-61a5b454733e","97ff4941-349c-4f08-9ad1-3af5fe7dedf0","98ad41e5-935b-4d45-9800-f46988619ba5","98bdf0f4-575b-45af-8f48-992c1b458730","98bdfbf7-3df0-4115-9eb5-ca293bab4c6b","99704b67-8b70-4fdc-8567-12c3c9493115","997fae84-84fa-41cd-91eb-6c052a55e383","99d9a447-e244-46e7-97da-ccc36b2a3903","9a212120-c56d-4537-b41c-56a89207423f","9a645ac3-e594-4873-ac06-02ff92a8a8f2","9a965410-86cd-47d0-b369-75f95fae3da9","9ab72574-1f77-49b2-901a-3d5d60a6e21b","9af20258-4fad-4845-961f-333a54b415b9","9b36a839-fa12-40a3-b144-98f481b5b0c1","9b56097d-b33f-4836-aad9-09fda1a302fb","9bb92f01-79ad-450c-9034-0354e806af35","9c20d725-9b40-4019-aebb-a3e5359b0a35","9c43c4ed-08c1-40d1-aeb9-2b636a508445","9cb281b3-c4dd-451b-b05c-bbbbaa83b1e0","9cbce9f0-4344-4b97-b0dc-c96865220f85","9cd775cd-9e6e-4c6b-8724-3cf3c66f8751","9d0c7355-be0b-46af-a4e5-26de4adb1956","9d667cfa-51a5-46c6-b678-316db453a20f","9e835dd6-6e2e-45a5-948d-3400d659e009","9eb3bbe6-b977-47de-ac91-aab7fb820692","9eccdcac-4925-4d00-831e-a50802b5ccf2","9ef21004-9ae2-4ad6-be57-f4500459ff43","9f0094ad-a268-4447-9d8b-9678fc226e51","9f376c9f-7890-41eb-85fd-804d40f68cae","9fafa506-c75f-4fba-bd31-926b562b850f","9ffad292-da76-402f-a85f-b3f2fb7412b9","a00ee31b-03c3-4ea8-aac5-554df94992a2","a021eeac-b65c-4fb0-b65f-8644561c9f52","a0c35b99-5460-42de-8fc7-f762280ccbc0","a0c42b2b-e072-4a6b-b679-ff9d7feb2728","a0cfb8bf-e279-487b-aa6c-0c6727c432d8","a13c7473-57d8-4e34-9cd5-b8b265589495","a1a8cc02-650c-4277-b68a-e042503e5b1a","a1ccf4a9-8c38-4ca2-8b53-cc4d6c628d67","a257a5e8-1a57-4fd6-99a2-9246655702f7","a26fe5c0-fdef-4d4a-ad37-87ad0f26003c","a2bd2ac9-a250-49a9-b380-4291c04eb559","a2cb04ff-9ea4-44bc-92bf-18291800c066","a362c91d-ba90-4cbe-bd86-15fa8e8b821a","a36dc7f0-8872-4de9-9649-08684b3bf892","a37a155a-85ef-4544-b6b3-9d188b962b0b","a3ec050a-e1b9-43ea-b819-794e48e3ef42","a41eaa43-efef-4cd2-8818-1826c7197a88","a48bedc5-096a-4656-acdb-e0b0e3670608","a499f5b3-e831-47b0-a56b-36538957bbbe","a4a69a2e-45dd-4696-a331-aef56b554efb","a547f9a2-2197-4d25-889e-84007f64063d","a57050bf-2ebf-4794-8bdf-263d2816b247","a589dae2-c217-4c59-aa65-8c280e2e3691","a5b98565-1535-414b-96b0-28ddfc409234","a64c2723-385e-4cb2-a1d5-4f3838dba986","a6f5b603-e914-4020-85f3-4ce2cbb0c1de","a7008990-9dcb-4542-8260-9f0f0523f1f9","a70a2ce6-6167-495b-8328-5f898f809ba2","a756a5aa-6c3f-4628-a747-34033caa268f","a79dc21b-1fc4-4076-8675-f4ee48289257","a7c6399e-a4e5-4c72-8d4e-dc43f06ca1a4","a7c6c429-ad38-4b63-a189-df0492b97b21","a7cdee55-df73-448e-964a-8a9fe6e5682e","a81d8c3d-d8cf-4b77-8ca4-39268afef4f4","a850dbc0-cce8-4f1b-b826-43be2c140878","a8542e11-5dd3-4232-a144-4298651cd2fb","a8836bb1-d98e-4766-acbf-e0efb575e5dc","a8e4b446-3e24-45c9-a13a-5b835d7f400c","a8e8ca43-8a5e-494b-8dea-a25d171e631c","a9015b0b-73a1-42ee-bd9c-af8bdec5bc6c","a9036594-571e-4b0e-936e-a4d597d612c4","a90c7d2b-e0c4-483d-a835-883ca22149be","a9a77e76-33fa-4a85-9e92-0b139bdc2d34","a9aa90cc-b5e9-4772-97d3-985134d77410","aa69d863-cfe6-4f6a-93c0-d5c6f6311b1f","aa7ffd1e-2739-4d21-8dcd-7149335731bb","aa8460e1-8c8f-49f4-a468-8cc0eb4f60b4","aad065cd-e47b-4db4-b557-416b3d13d9b2","aae63320-c4a8-4072-8476-6b1644a4d3fb","ab77bcfc-f85d-4150-b00a-e1dd54b76433","ab7804e5-c7bc-4a50-bed9-99332a5b3561","ac8ed6b0-e32f-42d0-aed0-57fd1b405865","ac978015-3e62-42fa-a3a1-cb2d4bd7be53","acae7d0a-3dfb-4f76-9228-908227265316","ace61f66-6a33-4e92-9f32-9cee5a484253","ad972364-0696-4572-ae22-4faf9c683bfa","adc9fe77-1475-4f84-8a5c-8358fe9c87f7","adddc860-db4a-4f93-b713-97d1cd7be404","ae075d24-dc20-48b9-84c7-1ffb56e9deac","ae380f4a-61fe-42db-8ed5-b2b04fc170ab","ae5b9d23-dc6a-45cc-922e-88d858620cd3","aedd12c7-0fdc-42a4-9e65-bfca4dbe7af2","af252d49-6468-4295-8efe-494b5f0ea8e3","afb395b5-ae7a-40c1-9591-6d71095d2146","afcd6b99-6f0a-482f-9535-a2753d99c45d","aff17665-5e1e-43d0-8356-79428a383c28","b01f993f-ea67-4a7b-bd6f-18fd345355cb","b05615d6-5ac5-45c8-80b3-141a90b0edf5","b06c7357-45ec-4713-b3f4-af0b74829c4f","b096c1ad-6d6c-431b-9ac4-6bcc8ff52307","b0d821f9-2dea-496e-8ef6-e436cadcfeb4","b1a932c4-dffe-4054-ac4f-2e6e662e6c70","b22df70f-16eb-4999-9406-27f8a2aa9d49","b2a6d8eb-8074-485c-9234-3043c3406c38","b2e98eaa-0502-4786-890f-39c222186df3","b31f3ddb-246b-46a4-94f7-88f0abcdb7ac","b34e642c-8a5e-4c2f-8281-8320a96e2592","b40463e0-6412-455b-9e72-026990a46811","b418c743-1115-450f-97eb-b633dda077b2","b4739b20-ecce-4119-8123-0e25957c468f","b48d0222-f29d-48ba-bc28-a8ba50329cd4","b5292563-00d5-45b1-9c55-11c800c95b34","b52fa9c8-f018-4e95-98fe-6b26f54f3f67","b556bfb9-8b7e-45b9-acb0-9752ff692c8c","b566f97f-c9e1-4bc7-bc28-0a497935ba89","b5731f72-cbdc-45ed-82ec-8b7c30451c35","b593f6f3-a4ad-4ae0-9e10-d0c62bc8bbc9","b5d72bd3-f24d-4c40-bfe1-595122016f45","b63ed364-74de-4dca-83f4-ac36f0dc68bf","b773ac8e-9401-45a5-b210-ffedf6ec7aed","b7b28e63-b13f-4694-a3d8-7096046b029d","b836b475-f0e5-46a3-bb73-d84b82fcc8a3","b859907e-28ef-4aa5-b56a-d37b8da04a52","b8898e2e-16db-4a54-a604-ae33f423ae84","b8a08d36-54ed-48d1-bde9-c01502382601","b8ef53f6-79bc-45f2-bc99-8e703753189c","b8f4f5e2-88f9-43d5-b619-f36ebd156d31","b916721a-2af3-47de-9ac9-1ce870348c52","b93e7df1-3686-4ef9-be20-1b444b80e6a7","b94320fc-b301-4f7d-b348-8fc312b5107a","b9893bfc-1928-452d-99f9-a1642421d1a1","b99f2c20-ce54-43db-918c-682495e9cfc9","ba451271-89bf-4a70-9f34-e63a5bbb2d0d","ba745641-cdb0-4fa5-ab92-267395dd692b","bb0642ad-9ed9-408e-ae77-61509b803f44","bb295d8f-f001-491e-baf7-e4807d5be53c","bb30be5d-eaf5-40e2-91c3-fde8ad66d9ff","bbbf70e1-cdc5-4bab-8a7a-2d5393ac5f2d","bbda047a-ae17-47aa-ab47-b2283d0550e2","bbe061b2-f9cc-4647-af44-0ef1bdad3ed3","bbef5630-2e25-413a-8233-729857e939d2","bc14f26f-9d7e-4442-b3f1-30427c88fa7c","bcf084fd-2d08-44f6-aacc-fd36aa60de59","bda39bd3-6947-40b7-9dc7-dd8e7957f3ca","bdf61294-e494-4cf8-b6d3-a32772b8b080","be63a9de-f55f-462d-9946-b9f7f562281c","be8a87d1-bd07-420d-866d-4976fa594666","be924fdb-5140-400f-bf7d-634ca9930edb","be95b55b-6e65-49ea-879e-faa3cfc0cd1f","bebbf9e0-4038-4de1-b8b3-a8250f17369d","bed2698d-1aae-4a18-9eeb-b085727c6af3","beff2dbd-652a-4ef4-9306-d694d98f12c6","bf358ecb-2ff4-41e4-8d94-6053c3dff665","bf4e03c4-bb3e-4536-8332-1ce27527ba45","bf562fc7-b0c9-4f49-8309-28e715a721f6","bf880f12-16d0-4bef-b4f9-6831938c18db","bfc8d138-4417-4851-aad4-85c431106ec0","c0185a22-fe84-4b4f-8713-6582f5e758ef","c0b6d5d1-2a3f-4f60-8f51-a488fe29810e","c105009b-0898-485a-8026-669cfa0c2dd0","c142122e-03fe-4b6f-bfdd-2be97085780c","c15a8357-416e-468a-b025-3857e9271336","c18ee282-6b20-4e20-a9ca-3c2a5d295461","c1db17dc-e70a-47f3-aa13-6aa99c355afc","c1dc9993-dcc3-4286-ac43-d3ac9887a1ed","c23458ea-1656-43e7-9f5d-93d9d0f12b73","c24f3f3c-a159-43f6-adb7-dceb57811e01","c275b66a-0424-4bf8-ad0f-fbf0196b34ef","c2b471d4-d22c-432b-92df-a293a63fe9bc","c3127b5a-e76e-4322-8a44-365136ae5b85","c347b669-a757-4a04-a6e5-2d03181fb891","c357c3c6-f701-42e7-8401-ae53d107b33d","c38740e5-ab04-412d-b214-90c4029d5146","c3e30c09-a321-4678-b7de-fd80f011abec","c3f707ca-f3f1-47ab-b52c-2e95ac26a70b","c48f99bf-9e13-4c6c-82f3-abb34ba1fdf3","c4a9a83b-9e1f-473f-80e5-7d3c08b90660","c5992564-97aa-455c-8981-1f3b2329a3ea","c5c1d99c-0465-47c9-849b-ab01dea12312","c5d86743-b039-4e66-bfb4-32ba73363cca","c6487aa6-925b-4724-bdfc-660b6d13f90b","c65ae106-ccc6-49fd-9d44-57ab6a86beac","c6d57f00-ac1b-44a0-83b4-5ba6b63ddba3","c6d6e225-bb00-4cdc-9961-8948e6db1707","c7d7dee4-bd92-4d09-8e73-cc8b94e20e62","c856daa9-a63d-4c85-aee1-0cd0cff3ca56","c8825e7f-3bc8-4222-8e69-072ffed990bc","c93bb6c0-c501-4b02-9765-3e408a8e9541","c965e5a9-76a9-4e8a-823b-45f1b01b991c","c965e6e7-2cad-466a-ba55-77fde27701c3","c96e1294-c229-4715-ace7-5e3e89160b10","c9858d5a-f777-4fb4-af53-1b86f1d3dac9","ca0f5113-a509-492f-9a42-e24042802703","ca104c3c-f74a-4d4a-8682-692795ad9e76","ca53a2e9-efe8-42ab-bcbe-4933a7a555c9","ca5ed500-0631-422d-a72b-070b3815fc6e","cac1f513-dc7b-4062-8f0b-c6a0219bdc5a","cb5f5e62-0f34-46f3-8df4-d0735c3db29b","cb6c1427-e463-4ffe-971e-ff7d66d71786","cc034d5e-53b8-498b-bb0f-b0a95155e489","cc239702-036d-4501-b00d-4d3283f631b7","cd02527c-04a9-4220-a7d8-462c6d4709c6","cd079a9a-3b1e-46ab-8c01-da3003dd376e","ce992b38-8049-4477-956f-d09cf593d851","cedf19c0-0a61-4264-820b-f6bd2b78487a","cf0ca25d-870a-4ccc-9ea0-a380fe28b018","cf224e67-9ca4-486c-93f1-2ad281054e41","cf7e8313-9074-41c5-b466-e01212c6579c","cf7faa04-db17-4210-9a85-264f538a509f","cfbb4e2b-45ab-40a2-9354-4458eb3c7bb6","cfbdab16-b6c1-44f8-9169-877daac0128d","cfbe1563-1d86-43d0-8c94-ba4eed8f456d","cfcd944d-4559-4115-8ba0-6c406c999ffc","cfe1d424-ca7e-42e4-8052-d3d6b009d24b","cfefe836-407b-4c76-af8b-718e6c21d692","d0399e2d-0ffd-4031-a2ad-7f5d60cb7928","d05824dc-6730-44aa-9f8a-11c329aa9445","d082c293-d3cb-4baf-913c-9506707c3a9d","d09b0653-a002-4d11-a520-771be7d6b127","d0bcf798-a1af-401f-a43b-416b4e0db462","d0d50f8d-f9a5-48f0-94a4-fd911d5515c0","d10a23ca-463e-4ed2-91cb-4712af10feeb","d114902c-a874-4dfe-a4f1-7aeb69cd3bda","d1605043-0c2f-4f46-9612-31acc72e246f","d1638670-fb57-471a-9907-19381d153096","d167899c-b227-4aa6-af28-41caeaef70e8","d1b0cd0d-5136-4832-85cc-26a88c01677e","d20ceef3-1df7-41ac-a134-d84f10dbb6a5","d236873b-4a12-4001-a192-001f90498647","d27fd881-15e5-4fb1-9bac-c73146a5c684","d35fee52-5038-4937-9eed-44e8df069829","d38c15d6-71e1-4e6d-8840-d8d44c13bd7b","d4403b2b-866c-4337-babe-03d9c0a37190","d4921fe5-d8ec-45fd-846c-77064a9b9555","d4ddc073-69f0-4edc-b534-3e3cfe417667","d5144496-9692-49e6-9294-b586e84acdb9","d53be936-cc77-4fcb-abf2-d3d654fdd32d","d5b8bc1d-9b27-402e-8c6c-f3c8ae8919d9","d5bfcf0f-7428-45e7-baa0-09d173169491","d60a8062-71c8-4be1-89b2-40770f5f7714","d72a89e2-3c1a-4434-b9ea-c79102ce7c7e","d7822149-1759-4fcf-9510-7801dfad749a","d8036c79-69a2-4b3e-b62b-a6bc28324280","d82ee1dc-82d8-497d-b40a-68d368698f32","d8412bfc-a970-4f80-b155-cdca7d7d5296","d86dd3fb-eb2a-40d5-ad0d-83c98eddc714","d8a454b8-b475-4b9f-9eb0-c744f605bbd1","d8c8f8ed-320a-4e6b-b46c-980b1d748b57","d8e388a1-c619-47c3-aac0-0090f246f7a3","d92d74b6-e441-4c01-8864-f75a22ef3295","d945c679-e08f-4511-8011-7628f24aeb7b","d9772a68-4622-44bb-a5b8-10cdac8adac9","d97aa4ff-0407-4bbc-994a-629617b99db1","d983b982-2a2b-4d9a-8c26-058f2002b1e3","d9e6a959-01eb-48a8-9ce5-c0bf01886829","da096c56-e691-47c4-8afe-caaa6335109a","da58e650-2cef-40d7-a635-08a1d4b35f29","da651e5d-0c58-4342-a78b-2f7ae3faa7b2","dabed467-f3f0-47ab-b8aa-b2cdc2e2da90","db725a88-cb79-4670-9057-441b73a2d729","dbe046cb-a0df-46ee-b168-ebbbc2b98748","dc00c424-6ec6-4a89-a0f4-cd1f1762ce8a","dc07a73e-04f8-4e29-acd9-a792d38dfab6","dc330bd9-dd40-4a56-8ca5-507a9f296832","dc5c44d4-96ce-4f69-b32c-8e34278abb1a","dc8e4040-f520-438e-af25-21ef9f76594a","dca0ae38-298b-4c7e-9c46-6ddc10a157a4","dcbbb46b-4eb5-44c8-8484-de109a6dd025","dcc42419-3c81-47bd-8cd1-1076611d62d5","dd432095-7bbd-43e0-b96d-4348168eaf30","dd7c1669-330b-440b-b15e-3e43a32ad05e","dd9d4033-c197-45cb-8ea8-733baa206f8c","ddb653b4-526d-4e35-be67-19cb2b74bb83","de51bd6e-f437-4878-8f18-3c56e8b95c68","de66a681-e28d-4267-8069-b1d4615e398c","de7cc3d3-cff1-4476-9e28-412ed80acf48","dea3dd00-21f3-41fc-97e4-e768134423a0","deb2a584-4316-4f3e-a631-990dd741d04d","df000991-3da9-49cd-a200-b7bf3863da65","df039d46-8636-4719-9d67-419d8ba2c556","df5aa53a-ed8c-4765-bdba-274ecbfb5062","dfe79713-608a-4164-84f8-87e9c4113eb1","dfff8aaa-004c-4e0b-927f-24ce78255526","e0239105-c472-48f8-b0fe-1166523a3cde","e06b2888-cc2a-4c2d-8dad-773c06ea4176","e071bf0d-f73e-4c9b-858e-9f13831ee2a5","e11ad0dd-0e6c-444c-9468-cdd932efaa0c","e1b02363-b896-4faa-a001-9361877e21d3","e278f296-4be3-4fc9-91a1-30b34dff52d0","e27f6134-cf99-4b3a-85bd-02e39130fbb4","e2d64e87-5662-4b07-94d6-c2c7606eb799","e361a584-ace6-4533-bf19-a16fbd41f13c","e3ab4a03-a607-4701-9d7f-3aad00c0239d","e4602322-11ff-4979-85ef-7b9e0b385e52","e49f1bf2-5255-47df-8d66-a67aea6677d0","e4b44e7c-d4de-48c3-a6f5-56ce8546b201","e53cf68b-20fc-42d1-8dbd-d53d5d8a81b9","e577a454-f359-4ef8-b46a-222bef926703","e5a2c31c-4abf-451f-88e7-d060b0118e4d","e5bc95a7-37c4-43b1-853c-2222b552d8c0","e5e709fa-f980-44c6-b300-afe2d823e321","e62a1df4-a5ec-455e-9df2-e6c6f07a1cc9","e62b59d5-fb85-4234-b623-63e9e674a43b","e6841988-06ea-49d7-89c9-d747ae4c89d3","e6be172a-9031-4e9b-a87b-3d7b6c24ce49","e7793f42-91bc-4bf7-9c75-b8a017f820f3","e81e35d9-8305-45c8-8f40-9a1f2f228ad8","e8c46096-3dc4-4804-bda9-48dd31a05ea7","e8c49324-5a15-4ef8-99ac-e0d24bf43a88","e8e02caa-0318-4d5c-bae4-2006d085afe1","e92ddab8-21ec-4089-ac34-a9f02337b80b","e97f6d99-0fde-4274-b1b4-847f755ebb5a","e9dd783e-6c1e-4ca0-89b4-d0acc47ea768","ea18d63e-1fd8-4e85-84f0-8efde8c25220","ea68ccb1-9156-46b2-978d-65be444c83b2","ea9e81e0-31b6-495d-be1e-e36be9624cef","eb52d67d-fc6c-491c-a935-b7aba5a94025","eb7c908a-29bd-4e04-9e9e-08d10897bc6e","ebf96da1-b2d2-4f58-801b-b2dbcd5d6e0d","ec7c6b20-b805-4990-9abe-0601bed27d83","ecd66813-86f0-4883-b267-4881a1c88e55","ed4f401f-3624-4878-8281-f7f810e42eed","ed80685d-8d4f-47b2-9e0d-e0722210d76c","ed8a09b8-fa30-490a-8e54-8e9cd1ac29b0","edfe5aa2-001d-41de-852f-6c3535c88a62","ee173027-4d3e-42ab-9f32-f66e29f0e7ca","ee3a43bf-e2a9-4ab2-b5de-774fe03ad119","ee47fec9-0997-4fd4-ae39-1cd56c0de20a","eeed7a1d-9313-4f11-9e00-1ab21eb0d252","ef62e50e-8069-4bb7-9e79-93d94cc382e0","efec68dd-c13f-4bde-bd00-ffb62a5d1eb7","f00a5d13-c8c7-4a93-951b-c7716f05936b","f00a707c-4fa4-4eee-872c-eec0f70cfe5f","f00af680-24a8-43d3-b1f7-a27399836b61","f02ff913-1eba-415c-a19b-95e77b955be4","f05d1fb6-8e50-4eec-a389-d2e033e8cd2b","f0c56a74-74b2-4f81-a15c-415cc12fbc91","f0c81118-0de3-41b2-9581-5b149797da4a","f107b973-74d8-4cdb-a382-49d918280a69","f14da2bc-abf7-4c9c-ba82-bfb555542a3c","f19fdf2f-5063-48aa-ad03-46b09c7359a4","f1aff8bb-726b-4dfa-92c4-0f6605c18978","f1b9b7de-44e8-4600-9e4b-c4eb327c22f7","f1d3499f-07ae-469b-a172-66a24d4d5b8c","f20f33c9-e2c7-4312-9c38-20041434d6e1","f221bcb9-fb6a-4be2-8fb8-8cc6e0349234","f22be5ef-847d-42eb-80ca-54a7a11f613a","f258c94d-42f8-4520-9026-9c5f727d5cdc","f2e126a2-17ce-458c-a5e3-6c0f5cfa3e56","f370b506-7ec1-43cf-a1d4-116c8007cb57","f3892a50-7358-4916-bfa0-c696f79e4179","f3be87a7-119f-4a45-8813-a747523e6c84","f3da4ba8-ecb4-4191-8e53-b074b3a47b4a","f3dde8b6-175d-4d32-9f1f-290dfa4a615f","f4201830-2137-4cb2-9989-600aa73916a5","f44a36a6-6a9d-4245-b280-ac8f177a1d6e","f46c1fbc-d278-42e9-a016-51b6933473d5","f4f0561e-14af-4031-8f41-3ac4b8b010a4","f60b29c6-c642-4323-8e5a-61c068e8689b","f648d767-17f7-4041-b957-7d99b05f8f5b","f64f5b6b-b738-498a-b28b-a278b89fcfb4","f68e425b-df59-4157-a0fb-5eece7bcff53","f6c740ca-6501-4eec-9f11-69dcc6c0f86a","f6d1315b-a149-4f5b-9573-1f4f7ca2ed00","f6d72c89-7e49-48e9-a40a-5fca70da57d2","f7002b66-ad55-42b7-9bf5-037012f597eb","f705c8a6-a0eb-480a-8c6a-c7d05e7c4412","f76250bf-0714-45c8-a21e-74551b4c6128","f7c41e1e-6672-4563-8343-7cb0bd7b8521","f7ce8b1f-c8d4-44a2-b4a2-3c17aab820ab","f87daea9-0b1a-4715-872e-df50ea4c4cc0","f8944886-d379-47ec-8cc3-e2279bc07fc5","f894afe4-b829-4a95-970b-91c62b799475","f8b04f45-411e-4f9b-ba95-1a11099de711","f8f921d5-e669-461d-9fc6-4b2045d6ef18","f9310961-8c0d-40eb-859b-f39601bda452","f970f837-5fed-47fa-b2fc-9ee327da7fdf","f97d6540-d906-41d3-877d-14dc478e96d8","f98c2a88-963a-4db7-ad80-ba164828b664","f9ce5089-a009-4549-8fb6-67d1bacc8be7","f9d11b15-a1bb-43f7-a4e7-93928ead2256","f9d7a8e4-7dfc-4ec0-92b7-1e767855886b","f9f22169-ac80-4a10-a07e-344654850a61","fa1a8544-578c-49a3-8364-fc3315511e80","fa605f4c-fd5d-42f8-852f-fcdfaae1555b","fa6718d4-2981-4aeb-bb44-d91e7af172e6","fa825edd-3778-4599-8bc4-da4a14e75546","fab4a71a-a4a5-44c7-b79c-5e0ff7b0bdba","fadf8b6a-0cb4-41b0-9a83-996395f12e15","fafc0e00-bd42-433b-ae39-b77d4ece93ed","fb1f5290-ea52-4145-9469-922fa1f391fb","fbd7a713-4c30-47b5-98a0-903149cd8d56","fc0bdfe4-7bfd-4cce-89c6-b6652d1e15b1","fc140cf1-9002-481d-83a7-e6743989447a","fc17f31f-526d-4f08-8309-7b213e0aa864","fc66c81d-da2e-40c6-80b3-3b5e87c6e42c","fc978b8e-fb74-4a56-8481-adf73678a88d","fca16aa5-29ee-4140-89fe-e6fadf71e29e","fcb97a11-b23f-439f-a99f-7c8d13f4e4b9","fcd1c167-479f-464a-a490-e21ed83e22f5","fd476e7b-2f7a-4719-bc8e-b0481ac517dc","fdbab73c-2c37-4e10-89ef-737a5413c8c1","fdca46a0-40f9-4c44-abe6-e8b3b5acc0fd","fdddb0c9-fbdc-4ecb-8dba-0ce82f26b913","fdec23d8-64a2-414c-b695-2a9311d7e154","fe341e76-756c-4349-87a2-2f902d2485da","fe7e1011-6762-45ab-ad24-1d56521da1c4","feb06d75-6974-4128-a77c-a4a4c0e8b49e","ff684c21-a7c2-4912-86f8-685fbace8aab"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_DS_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1017872904,"decompressed_size_all_time":198898417410},"visibility":"Private & Public Next-Day","trigger":"Publication of Dispatch solution. Data includes all valid forecasts for that interval"},"INTERMITTENT_FORECAST_TRK":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"INTERMITTENT_FORECAST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec23.htm#175"],"comment":"Uniquely tracks which Intermittent Generation forecast was used for the DUID in which Dispatch run","primary_keys":["DUID","SETTLEMENTDATE"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Tracks to INTERMITTENT_DS_RUN.DUID","examples":["ADPPV1","ALDGASF1","ARWF1","AVLSF1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BERYLSF1","BLUEGSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOMENSF1","BOWWPV1","BRDDSF01","BROKENH1","BRYB1WF1","BRYB2WF2","BULGANA1","BUSF1","CATHROCK","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DARLSF1","DAYDSF1","DDSF1","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","ELAINWF1","EMERASF1","FINLYSF1","FLYCRKWF","GANGARR1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HD1WF1","HDWF1","HDWF2","HDWF3","HILLSTN1","HVWWPV1","JEMALNG1","JUNEESF1","KABANWF1","KARSF1","KEPSF1","KEPWF1","KERNGSP1","KIAMSF1","KIATAWF1","KINGASF1","KSP1","LANCSF1","LGAPWF1","LGAPWF2","LILYSF1","LIMOSF11","LIMOSF21","LKBONNY1","LKBONNY2","LKBONNY3","MACARTH1","MANNSF2","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBPS2PV1","MCINTYR1","MERCER01","METZSF1","MEWF1","MIDDLSF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MOUSF1","MRTLSWF1","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NEVERSF1","NEWENSF1","NEWENSF2","NUMURSF1","NYNGAN1","OAKEY1SF","OAKEY2SF","OAKLAND1","PAREPS1","PAREPW1","PARSF1","QPSFB1","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SMCSF1","SNOWNTH1","SNOWSTH1","SNOWTWN1","SRSF1","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","TARALGA1","TB2SF1","TBSF1","WAGGNSF1","WAMBOWF1","WAMBOWF2","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WINTSF1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WUNUSF1","WYASF1","YARANSF1","YATSF1","YENDWF1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"DateTime of the Dispatch run (dispatch interval ending)","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Tracks to INTERMITTENT_DS_RUN.FORECAST_PRIORITY, except for -1 which denotes SCADA or FCST, and 0 which denotes Last Target","examples":["-1","1","1217"],"is_integer":true,"num_int_bits":64},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Tracks to INTERMITTENT_DS_RUN.OFFERDATETIME","examples":["2026/08/31 23:55:15"],"parse_csv_as_string":true,"is_s_datetime":true},"ORIGIN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Tracks to INTERMITTENT_DS_RUN.ORIGIN, except when the forecast used is either SCADA or FCST or Last Target","examples":["ALNTARES","ARARATWF","AWEFS_ASEFS","BBPEM","BERBANKW","BOCOROCK","BODWF1","BULGANA","BUNGALA1","CLARESF1","CLEMGPWF","COLEAMSF","COLLECWF","COOPGWF","COROWASF","CROWLDWF","CSF1","DAYDSF","DIAMDGEN","DUNDWF","EEQMEWF","ENELAUS","FCST","FINLEYSF","FSNSW","GLENROSF","GOON","GPWF1","GRANHAWF","GSWF1A","GSWF1B","HAUGHTSF","HAYMSF","HORNSDAL","HORNSDL2","HWF3","JUNEESF","KARSF","KIATAPRJ","KINGARSF","KSFPROJT","LALLALWF","LIGHTSRC","LIMONSF","LKBWIND","MANILDRA","METZSF","MOORAWF","MOREEAC","MORTLSWF","MOUSF","MTGELLWF","MTMILLAR","MUNCRKSF","MUWARRA2","NEWENGSF","NEWGEN","NEWGRWF","NUMURKSF","NVTSF","PSF","ROSSRVER","RYEPARK","SALTCRK","SCADA","SEBSF","SHELLNEW","SLVRTN","SMCTSV","SNOWTOWN","SRSF1","STOCKYRD","STUBB1SF","SUNRSF","TAILEM","TARALGA","TBSF","WAGGAOPS","WANDOAN","WATERLWF","WDOWNS","WELLNTH","WGWF","WILDCATL","WINTONSF","WLWLSF1","WLWLSF2","WOLLARSF","WOODLAWN","WYALONG","WYASF"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_FORECAST_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":8319151,"decompressed_size_all_time":2121982480},"visibility":"Private & Public Next-Day","trigger":"Dispatch run"},"INTERMITTENT_GEN_FCST":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"FORECAST","REPORT_SUB_TYPE":"INTERMITTENT_GEN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#41"],"comment":"Identifying record for a given forecast of an intermittent generation. This table is the version table for the INTERMITTENT_GEN_FCST_DATA table which stores the individual forecast values. AEMO plans to remove this table in a Data Model version release after 5.6.","description":"Source\n\n \n\nINTERMITTENT_GEN_FCST_DATA updates every 30 minutes when AEMO issues a\nnew 30-minute forecast of intermittent generation out to 8 days ahead.\n\nVolume\n\n~18,000 rows per generator per year","primary_keys":["DUID","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of the intermittent generator.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time of forecast (AEST).","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"END_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time (AEST) of the final half-hour interval being forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"START_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time (AEST) of the first half-hour interval being forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"Versioning information for resolution back to AEMO's wind generation forecasting system.","is_integer":true,"unsigned_int":true,"num_int_bits":64}},"visibility":"Private","trigger":"Every 30 minutes when AEMO issues a new 30-minute forecast of intermittent generation out to 8 days ahead"},"INTERMITTENT_GEN_FCST_DATA":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"FORECAST","REPORT_SUB_TYPE":"INTERMITTENT_GEN_DATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#48"],"comment":"Stores the forecast generation (MW) for each interval within a given forecast of an intermittent generator. AEMO plans to remove this table in a Data Model version release after 5.6.","description":"Source\n\nINTERMITTENT_GEN_FCST_DATA updates every 30 minutes when AEMO issues a\nnew 30-minute forecast of wind generation out to 8 days ahead.\n\nVolume\n\n~1,500,000 rows per generator per year","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of the intermittent generator","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time (AEST) of the halfhour interval being forecast","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time of forecast (AEST).","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"POWERMEAN":{"sql_type":"NUMBER(9,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The average forecast value in MW at the interval end","is_float":true},"POWERPOE50":{"sql_type":"NUMBER(9,3)","pl_type":"pl.Float64","mandatory":false,"comment":"50% probability of exceedance forecast value in MW at the interval end","is_float":true},"POWERPOEHIGH":{"sql_type":"NUMBER(9,3)","pl_type":"pl.Float64","mandatory":false,"comment":"10% probability of exceedance forecast value in MW at the interval end","is_float":true},"POWERPOELOW":{"sql_type":"NUMBER(9,3)","pl_type":"pl.Float64","mandatory":false,"comment":"90% probability of exceedance forecast value in MW at the interval end","is_float":true}},"visibility":"Private","trigger":"Every 30 minutes when AEMO issues a new 30-minute forecast of wind generation out to 8 days ahead"},"INTERMITTENT_GEN_FCST_P5_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_FCST_P5_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#55"],"comment":"Contains forecast predictions for intermittent wind and solar units, with a 5-minute resolution over the hour-ahead P5MIN timeframe. This is the child table of the parent table INTERMITTENT_GEN_FCST_P5_RUN, which contains the corresponding forecast runs.","primary_keys":["DUID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","FORECAST_TYPE","INTERVAL_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier for which this forecast applies.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of forecast, for example, POE_10, POE_50, POE_90, MEAN and so on."},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval-ending) for the period that this forecast applies to, within the current forecast_run_datetime.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier","is_categorical":true},"FORECAST_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast value in MW.","is_float":true}},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes when a new intermittent generator forecast is available, covering the 2 hours ahead horizon with 5-minute resolution"},"INTERMITTENT_GEN_FCST_P5_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_FCST_P5_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#61"],"comment":"Contains forecast runs for intermittent wind and solar units, with a 5-minute resolution over the hour-ahead P5MIN timeframe. This is the parent table to the child table INTERMITTENT_GEN_FCST_P5_PRED, which contains the corresponding forecast predictions over the full horizon.","primary_keys":["DUID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier for which this forecast applies.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the forecast run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the forecast run. This column is not made available to the public."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast run. This column is not made available to the public."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the forecast run was suppressed by the provider when submitted. Suppressed forecasts are not used by downstream systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true},"TRANSACTION_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Transaction identifier for receiving the forecast run."}},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes when a new intermittent generator forecast is available, covering the 2 hours ahead horizon with 5-minute resolution"},"INTERMITTENT_GEN_FCST_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_FCST_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#67"],"comment":"Contains forecast predictions for intermittent wind and solar units, with a 30-minute resolution over the week-ahead PD/STPASA timeframe. This is the child table of the parent table INTERMITTENT_GEN_FCST_RUN, which contains the corresponding forecast runs.","primary_keys":["DUID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","FORECAST_TYPE","INTERVAL_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier for which this forecast applies.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of forecast, for example, POE_10, POE_50, POE_90, MEAN and so on."},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval-ending) for the period that this forecast applies to, within the current forecast_run_datetime.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier","is_categorical":true},"FORECAST_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast value in MW.","is_float":true}},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes when a new intermittent generator forecast is available, covering the 8 days ahead horizon with 30-minute resolution"},"INTERMITTENT_GEN_FCST_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_FCST_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#73"],"comment":"Contains forecast runs for intermittent wind and solar units, with a 30-minute resolution over the week-ahead PD/STPASA timeframe. This is the parent table to the child table INTERMITTENT_GEN_FCST_PRED, which contains the corresponding forecast predictions over the full horizon.","primary_keys":["DUID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier for which this forecast applies.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the forecast run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the forecast run. This column is not made available to the public."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast run. This column is not made available to the public."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the forecast run was suppressed by the provider when submitted. Suppressed forecasts are not used by downstream systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true},"TRANSACTION_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Transaction identifier for receiving the forecast run"}},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes when a new intermittent generator forecast is available, covering the 8 days ahead horizon with 30-minute resolution"},"INTERMITTENT_GEN_LIMIT":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_LIMIT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#79"],"comment":"A submission of Upper MW Limit for an intermittent generating unit, by Trading Day and Trading Interval","primary_keys":["DUID","OFFERDATETIME","PERIODID","TRADINGDATE"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["BALDHWF1","BANGOWF1","BANGOWF2","BERYLSF1","BLUFF1","BNGSF1","BNGSF2","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this unit availability submission was loaded","examples":["2026/08/20 13:41:12"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval number (1...48) within this TRADINGDATE for which UPPERMWLIMIT applies","examples":["1","48"],"is_integer":true,"num_int_bits":16},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trading Day for which this unit availability submission applies","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"UPPERMWLIMIT":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum imposed MW limit (down regulation in AWEFS/ASEFS). Value between 0 and the registered DUID Maximum Capacity. Value = -1 means no limit applies.","examples":["0","-1","5","110"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_GEN_LIMIT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":9971657,"decompressed_size_all_time":1215054180},"visibility":"Private & Public Next-Day","trigger":"On participant data submission"},"INTERMITTENT_GEN_LIMIT_DAY":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_LIMIT_DAY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#85"],"comment":"Summary record for an Upper MW Limit submission for an intermittent generating unit for a Trading Day","primary_keys":["DUID","OFFERDATETIME","TRADINGDATE"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["BALDHWF1","BANGOWF1","BANGOWF2","BERYLSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BOMENSF1","BOWWPV1","BRDDSF01","BROKENH1","BRYB1WF1","BULGANA1","CATHROCK","CHALLHWF","CHILDSF1","CHYTWF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COOPGWF1","CROOKWF2","CRURWF1","CTHLWF1","DAYDSF1","DUNDWF1","DUNDWF2","DUNDWF3","ELAINWF1","FLYCRKWF","GANGARR1","GIRGSF","GNNDHSF1","GOESF1","GOONSF1","GPWFWST2","GULLRWF1","GULLRWF2","GUNNING1","HALLWF1","HALLWF2","HAYMSF1","HDWF1","HDWF3","KABANWF1","KARSF1","KEPSF1","KEPWF1","KIAMSF1","KIATAWF1","KINGASF1","LANCSF1","LGAPWF1","LGAPWF2","LILYSF1","LKBONNY1","LKBONNY2","LKBONNY3","MACARTH1","MANNSF2","MANSLR1","MERCER01","MOORAWF1","MOREESF1","MRTLSWF1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this unit availability submission was loaded","examples":["2025/10/02 22:44:40"],"parse_csv_as_string":true,"is_s_datetime":true},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trading Day for which this unit availability submission applies","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"AUTHORISEDBYPARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Participant entering the unit availability submission","examples":["ALNTBHWF","BANGOWF2","BBPEM","BERYBKWF","BOCOROCK","BOMENSF","BULGANA","BUNGALA1","BUNGALA2","BWFTRUST","CATHROCK","CHALLHWF","CHERRYWF","CLEANCO","CNUNDAWF","COOPGWF","CROOKWD","CRUDINE","CSF1","DAYDSF","DUNDWF","EEQLILY","ENELAUS","FSNSW","GBATEAST","GOON","GPWF2","GUNNEDAH","GUNNING","HAYMSF","HORNSDAL","HWF3","KARSF","KENNEDYE","KIATAPRJ","KINGARSF","KSFPROJT","LALLALWF","LANCASF","LINGAPWF","LKBWIND","MANILDRA","MANNUMS2","MOORAWF","MOREEAC","MORTLSWF","MTMERCER","NEWGRWF","SAWCML","SHELLNEW","SOUTHYD2","STANCCWF","TIPSCO","TLTSFS","WILDCATL"]},"AUTHORISEDBYUSER":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"User entering the unit availability submission","examples":["API5MSNEMBIDA","API5MSWOSA","APPSAE","BANGLG","BANGXL","BERYLPRODZL","BWF02LG","BWF02XL","CCBOMEN2","CCWF1ET","CCWF1LG","CCWF1MB","CCWF1SL","CCWF1XL","CNUNDAWFAPIBID","CRWFET","CRWFLG","EOALINTAPROD","GAENERGYOFR","GBATEASTAPIBID","GPWF2EOT1","HABITATENERGY2","HSAVAILBRYB1WF1","HSAVAILCROOKWF2","HSAVAILGOONSF1","HSAVAILLILYSF1","HSAVAILMOREESF","HWF1PROA3","HWF3PROA2","KIATAPRJOWE","KSF1OWE1","LANCASTR","LLWFOWEJPROD","LLWFOWEOPPROD","MANSFPRODZL","MOREEACABHISHEK","MOREEACJOSEPHAS","NEXIFOWE1","OEFRSTPROD","OEHMCBUPROD","OEMOOR1","OWEKEPP","OWPROD1","PATANGMNI","PPPROD","PPPROD2","PRODENERGYO","PRODMSF2HE1","PUBUN1OW","PUBUN2OW","QUINGRAG","QUINGRAP","QUINGRJS","QUINGRJT","SAWCMLCQE2","TRAHEALY","TRGUNSF","TRPAKING","TRSGREENPA","TRTDESAI","TRTPIMENTA"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2025/10/02 22:44:40"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","examples":["ALNTBHWF","BANGOWF2","BBPEM","BERYBKWF","BOCOROCK","BOMENSF","BULGANA","BUNGALA1","BUNGALA2","BWFTRUST","CATHROCK","CHALLHWF","CHERRYWF","CLEANCO","CNUNDAWF","COOPGWF","CROOKWD","CRUDINE","CSF1","DAYDSF","DUNDWF","EEQLILY","ENELAUS","FSNSW","GBATEAST","GOON","GPWF2","GUNNEDAH","GUNNING","HAYMSF","HORNSDAL","HWF3","KARSF","KENNEDYE","KIATAPRJ","KINGARSF","KSFPROJT","LALLALWF","LANCASF","LINGAPWF","LKBWIND","MANILDRA","MANNUMS2","MOORAWF","MOREEAC","MORTLSWF","MTMERCER","NEWGRWF","SAWCML","SHELLNEW","SOUTHYD2","STANCCWF","TIPSCO","TLTSFS","WILDCATL"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_GEN_LIMIT_DAY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":574076,"decompressed_size_all_time":76961060},"visibility":"Private & Public Next-Day","trigger":"On participant data submission"},"INTERMITTENT_GEN_SCADA":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"INTERMITTENT_GEN_SCADA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#91"],"comment":"INTERMITTENT_GEN_SCADA provides the SCADA Availability for every intermittent generating unit, including Elements Available (wind turbines/solar inverters) and Local Limit","primary_keys":["DUID","RUN_DATETIME","SCADA_TYPE"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["ADPPV1","ALDGASF1","ARWF1","AVLSF1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BERYLSF1","BLUEGSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOMENSF1","BOWWPV1","BROKENH1","BRYB1WF1","BRYB2WF2","BULGANA1","CAPTL_WF","CATHROCK","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWASF1","CSPVPS1","CTHLWF1","CULLRGWF","DARLSF1","DAYDSF1","DDSF1","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","ELAINWF1","EMERASF1","FINLYSF1","FLYCRKWF","GANGARR1","GANNSF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOONSF1","GPWFEST1","GPWFEST2","GPWFEST3","GRANWF1","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HD1WF1","HDWF1","HDWF2","HDWF3","HILLSTN1","HUGSF1","HVWWPV1","JEMALNG1","JUNEESF1","KABANWF1","KARSF1","KEPSF1","KEPWF1","KERNGSP1","KIAMSF1","KIATAWF1","KINGASF1","KSP1","LGAPWF1","LGAPWF2","LILYSF1","LIMOSF11","LIMOSF21","LKBONNY1","LKBONNY2","LKBONNY3","LRSF1","MACARTH1","MANNSF2","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBPS2PV1","MCINTYR1","MERCER01","METZSF1","MEWF1","MIDDLSF1","MLWF1","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MOUSF1","MRTLSWF1","MTGELWF1","MTMILLAR","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NEVERSF1","NEWENSF1","NEWENSF2","NUMURSF1","NYNGAN1","OAKEY1SF","OAKEY2SF","OAKLAND1","PAREPS1","PAREPW1","PARSF1","PORTWF","RRSF1","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SMCSF1","SNOWNTH1","SNOWSTH1","SNOWTWN1","SRSF1","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","TARALGA1","TB2SF1","TBSF1","WAGGNSF1","WANDSF1","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WINTSF1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLGSF1","WOOLNTH1","WPWF","WRSF1","WRWF1","WSTWYSF1","WUNUSF1","WYASF1","YARANSF1","YATSF1","YENDWF1","YSWF1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time of the dispatch interval (interval ending)","examples":["2025/04/11 10:35:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SCADA_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"SCADA snapshot for intermittent generating unit at start of interval for a specified SCADA signal type. ELAV = Total Elements Available (# turbines for wind farms, # inverters for solar farms); LOCL = Local Limit (MW).","examples":["ELAV","LOCL"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2025/04/12 04:11:34"],"parse_csv_as_string":true,"is_s_datetime":true},"SCADA_QUALITY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"SCADA quality snapshot for intermittent generating unit at start of interval for a specified SCADA signal type.","examples":["Good","ManuallyReplaced","NotInService","Suspect","Uninitialised","Unreasonable"]},"SCADA_VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SCADA value snapshot for intermittent generating unit at start of interval for a specified SCADA signal type.","examples":["0.41305","0","2","1076"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23INTERMITTENT_GEN_SCADA%23FILE02%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":499351841,"decompressed_size_all_time":63504723350},"visibility":"Private & Public Next-Day","trigger":"Shows data for every 5 minutes for all Intermittent Generating Units"},"INTERMITTENT_P5_PRED":{"package":"DEMAND_FORECASTS","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#97"],"comment":"Unconstrained Intermittent Generation Forecasts (UIGF) for 5-Minute Pre-dispatch. AEMO plans to remove this table in a Data Model version release after 5.6.","primary_keys":["DUID","FORECAST_PRIORITY","INTERVAL_DATETIME","OFFERDATETIME","ORIGIN","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"DUID (or Area for non-scheduled) where this forecast applies","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Unsuppressed forecasts with higher priority values are used in 5-Minute Predispatch in preference to unsuppressed forecasts with lower priority values","is_integer":true,"num_int_bits":64},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Interval within the current RUN_DATETIME where this forecast applies (dispatch interval ending)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this forecast submission was loaded","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ORIGIN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Origin of this forecast (PARTICIPANTID, AWEFS/ASEFS, or another vendor)"},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time of the first interval of 5-Minute Predispatch where the forecast applies (dispatch interval ending)","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_MEAN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast MW value for this interval_DateTime","is_float":true},"FORECAST_POE10":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 10% POE MW value for this interval_DateTime","is_float":true},"FORECAST_POE50":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 50% POE MW value for this interval_DateTime.","is_float":true},"FORECAST_POE90":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast 90% POE MW value for this interval_DateTime","is_float":true}},"visibility":"Private","trigger":"Publication of 5-Minute Pre-dispatch solution. Data includes all valid forecasts for that interval"},"INTERMITTENT_P5_RUN":{"package":"DEMAND_FORECASTS","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#103"],"comment":"Unconstrained Intermittent Generation Forecasts (UIGF) for 5-Minute Pre-dispatch. AEMO plans to remove this table in a Data Model version release after 5.6.","primary_keys":["DUID","FORECAST_PRIORITY","OFFERDATETIME","ORIGIN","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"DUID (or Area for non-scheduled) where this forecast applies","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Unsuppressed forecasts with higher priority values are used in 5-Minute Predispatch in preference to unsuppressed forecasts with lower priority values","is_integer":true,"num_int_bits":64},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this forecast submission was loaded","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ORIGIN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Origin of this forecast (PARTICIPANTID, AWEFS/ASEFS, or another vendor)"},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time of the first interval of 5-minute pre-dispatch where the forecast applies.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Authorising officer of this forecast"},"COMMENTS":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata relating to the forecast."},"PARTICIPANT_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Participant can document when the forecast was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SUPPRESSED_AEMO":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Was this forecast suppressed by AEMO? Suppressed = 1,Not suppressed =0","is_integer":true,"num_int_bits":8},"SUPPRESSED_PARTICIPANT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Was this forecast suppressed by the participant? Suppressed submissions may not be used, Suppressed = 1, Not suppressed =0","is_integer":true,"num_int_bits":8},"TRANSACTION_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Uniquely identifies this interaction"}},"visibility":"Private","trigger":"Publication of 5-Minute Predispatch solution. Data includes all valid forecasts for that 5-Minute Predispatch ru"},"INTRAREGIONALLOC":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"INTRAREGIONALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#64"],"comment":"INTRAREGIONALLOC shows allocations of intra-regional residues to participants.","description":"INTRAREGIONALLOC data is confidential to the relevant participant.\n\nSource\n\nThe data in INTRAREGIONALLOC changes infrequently.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date of Allocation Details","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"Version No in respect to effective date","is_integer":true,"unsigned_int":true,"num_int_bits":32},"ALLOCATION":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allocation Percent / 100","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date/time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Infrequently"},"IRFMAMOUNT":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"IRFMAMOUNT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#17"],"comment":"IRFMAMOUNT sets out settlement amounts associated with Industrial Relations Forced Majeure events.","description":"IRFMAMOUNTis public data.\n\nSource\n\nIRFMAMOUNT is obsolete; was updated with each settlement run as\nrequired.","primary_keys":["IRFMID","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"IRFMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Unique Industrial Relations Force Majeure event","examples":["00W3","00W4","00W5","00W6"]},"PERIODID":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period","examples":["1","336"],"is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of record of event","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total settlement amount in $","examples":["0"],"is_float":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Person authorising amount"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date of event","examples":["2000/01/10 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"last changed","examples":["2000/01/17 15:25:17"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23IRFMAMOUNT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":5521,"decompressed_size_all_time":6404000},"visibility":"Public"},"IRFMEVENTS":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"IRFMEVENTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#26"],"comment":"IRFMEVENTS sets out specific Industrial Relations Forced Majeure events.","description":"IRFMEVENTS is public data.\n\nSource\n\nIRFMEVENTS updates with the occurrence of any such events.","primary_keys":["IRFMID"],"indexes":[["LASTCHANGED"]],"columns":{"IRFMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"examples":["00W3","00W4","00W5","00W6","00W7"]},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"examples":["2000/01/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["24","48"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2000/01/17 15:25:17"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"examples":["2000/01/10 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"examples":["1","27"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23IRFMEVENTS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":488,"decompressed_size_all_time":641750},"visibility":"Public","trigger":"When there is a Industrial Relations Forced Majeure event"},"LOSSFACTORMODEL":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"LOSSFACTORMODEL","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#73"],"comment":"LOSSFACTORMODEL sets out the demand coefficients for each interconnector, used by LP Solver modelling of interconnector flows.","description":"LOSSFACTORMODEL is public data, so is available to all participants.\n\nSource\n\nLOSSFACTORMODEL only changes annually, when there is a change in the\ninterconnector.","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date data set is effective","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the interconnector.","examples":["N-Q-MNSP1","NSW1-QLD1","NSW1-SA1","SNOWY1","T-V-MNSP1","V-S-MNSP1","V-SA","V-SN","VIC1-NSW1"],"is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier for a connection point of the interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number within effective date of the status proposed","examples":["1","4"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEMANDCOEFFICIENT":{"sql_type":"NUMBER(27,17)","pl_type":"pl.Float64","mandatory":false,"comment":"The coefficient applied to the region demand in the calculation of the interconnector loss factor","examples":["-0.00000010835","0.000000018182","0","0.000138"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2003/11/25 15:41:18"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23LOSSFACTORMODEL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3966,"decompressed_size_all_time":4515460},"visibility":"Public","trigger":"Annually, when there is a change in the interconnector"},"LOSSMODEL":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"LOSSMODEL","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#82"],"comment":"LOSSMODEL sets out segment breakpoints in loss model for each interconnector, used by LP Solver modelling of interconnector flows.","description":"LOSSMODEL data is public, so is available to all participants.\n\nSource\n\nLOSSMODEL only changes annually, when there is a change in the\ninterconnector.","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","LOSSSEGMENT","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date data set is effective","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","SNOWY1","V-SA","V-SN"],"is_categorical":true},"LOSSSEGMENT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":true,"comment":"Segment Identifier (1 to 80 at present)","examples":["1","81"],"is_integer":true,"num_int_bits":32},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number within effective date","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2003/11/25 15:41:18"],"parse_csv_as_string":true,"is_s_datetime":true},"MWBREAKPOINT":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW Value for segment","examples":["0","-5","5","-2125","3813"],"is_integer":true,"num_int_bits":32},"LOSSFACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Not used","unused":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23LOSSMODEL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":107843,"decompressed_size_all_time":119546410},"visibility":"Public","trigger":"Annually, when there is a change in the interconnector"},"MARKETFEE":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKETFEE","VERSION":1},{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKETFEE","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#40"],"comment":"MARKETFEE sets out fee type and period for each market fee.","description":"MARKETFEE data is public, so is available to all participants.\n\nSource\n\nMARKETFEE updates when fees change.","primary_keys":["MARKETFEEID"],"indexes":[["LASTCHANGED"]],"columns":{"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for Market Fee","examples":["F_5MSGS_WP","F_ADMIN","F_ALO_GEN","F_ALO_MG","F_ALO_MSG","F_ALO_WP","F_COMA_REV","F_CYB_WP","F_DER_WP","F_EST_NECA","F_EST_NEMM","F_EUA_NECA","F_FRC","F_GEN_NECA","F_GEN_NEMM","F_GEN_REV","F_MG_REV","F_MSG_REV","F_NEM25WP","F_PAR_COMA","F_SVC_IT","MC_5MS_AC1","MC_5MS_AC2","MC_5MS_AS1","MC_5MS_AS2","MC_5MS_CP","MC_COR_AC1","MC_COR_AC2","MC_COR_AS1","MC_COR_AS2","MC_COR_CP","MC_CYB_AC1","MC_CYB_AC2","MC_CYB_AS1","MC_CYB_AS2","MC_CYB_CP","MC_ECA_CP","MC_REF_AC1","MC_REF_AC2","MC_REF_AS1","MC_REF_AS2","MC_REF_CP","MC_RET_CP","V_5MGS_CP2","V_5MGS_MC2","V_5MGS_MC3","V_5MSGS_CP","V_5MSGS_MC","V_ADMIN","V_ALO_CP","V_ALO_CP2","V_ALO_CUS2","V_ALO_CUS3","V_ALO_CUST","V_CUST_NSM","V_CUST_NTP","V_CYB_CP","V_CYB_CP2","V_CYB_MC","V_CYB_MC2","V_CYB_MC3","V_DER_CP","V_DER_CP2","V_DER_MC","V_DER_MC2","V_DER_MC3","V_ECA","V_ECA2","V_ECA3","V_EST","V_EST_FRC","V_EST_NECA","V_EST_NEMM","V_EUA","V_EUA_NECA","V_FRC","V_FRC_CUS2","V_FRC_CUS3","V_FRC_CUST","V_GEN_CP","V_GEN_CP2","V_GEN_FRC","V_GEN_NECA","V_GEN_NEM2","V_GEN_NEM3","V_GEN_NEMM","V_METERING","V_NECA","V_NEM25CP","V_NEM25CP2","V_NEM25MC","V_NEM25MC2","V_NEM25MC3","V_NEMMCO","V_NET_NECA","V_PAR_COMA","V_PAR_COMP","V_PW_SYSOP","V_SETT","WP_5MS","WP_COR","WP_CYB","WP_PCF","WP_REF"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of market fee","examples":["Additional IT Services","Administration Fixed Fee","Administration Variable Fee","Allocated Fee per Connection Point","Cyber Security Fee","Cyber Security Fee per Connection Point","Cyber Security Variable Fee","Cyber Security Variable Fee - BDU","Cyber Security Variable Fee - CUST","DER Fee per Connection Point","DER Variable Fee","DER Variable Fee - BDU","DER Variable Fee - CUST","End User Advocacy","End User Advocacy Panel","Energy Consumers Australia","Energy Consumers Australia per Small CP","Establishment Fee","FRC Establishment ","FRC Operations","FRC Operations from 1 July 2019","Fee included for FPP funding purposes","IT Upgrade and 5MS/GS Compliance Fee - BDU","IT Upgrade and 5MS/GS Compliance Fee - CUST","IT Upgrade and 5MS/GS Compliance Variable Fee","IT Upgrade and 5MS/GS Compliance fee","IT Upgrade and 5MS/GS Fee per Connection Point","MC Cyber Security per ACE MWh","MC Cyber Security per ASOE MWh","MC Cyber Security per CP","MC Electricity Retail per Small/Large CP","MC IT Upgrade and 5MS/GS per ACE MWh","MC IT Upgrade and 5MS/GS per ASOE MWh","MC IT Upgrade and 5MS/GS per CP","MC NEM Core per ACE MWh","MC NEM Core per ASOE MWh","MC NEM Core per CP","MC NEM Reform per ACE MWh","MC NEM Reform per ASOE MWh","MC NEM Reform per CP","Market Customer Allocated Fee","Market Customer Allocated Fee - BDU","Market Customer Allocated Fee - CUST","Metering","Mkt AND Scheduled Gen & MNSP Alloc Fee","Mkt Gen & MNSP Alloc Fee","Mkt Gen Fee included for FPP funding purposes","Mkt OR Scheduled Gen & MNSP Alloc Fee","NECA (Including the Tribunal)","NECA End User Advocacy Fixed Fee","NECA Establishment Fixed Fee","NECA Establishment Variable Fee","NECA General Fixed Fee","NECA Variable Fee","NEM Establishment Fixed Fee","NEM Establishment Variable Fee","NEM General Fixed Fee","NEM Margin","NEM Variable Fee","NEM Variable Fee - BDU","NEM Variable Fee - CUST","NEM2025 Market Reform Fee","NEM2025 Market Reform Fee per Connection Point","NEM2025 Market Reform Variable Fee","NEM2025 Market Reform Variable Fee - BDU","NEM2025 Market Reform Variable Fee - CUST","National Electricity Tribunal Fee","National Smart Metering","National Transmission Planner","Participant Compensation Fund","Participant Compensation Fund per day","Power System Operations","Retail Contestability Fixed Fee","Retail Contestability Variable Fee","Settlements","Variable Fee per Connection Point","WP Cyber Security per day","WP IT Upgrade and 5MS/GS per day","WP NEM Core per day","WP NEM Reform per day","Wholesale participants DER fee","Wholesale participants allocated fee"]},"FEE_CLASS":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"examples":["EUA","NECA","NEMMCO"]},"GL_FINANCIALCODE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"examples":["2575","4550"]},"GL_TCODE":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"examples":["10","71"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2000/06/27 08:38:47"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEPERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Period type - PERIOD, DAILY, WEEKLY","examples":["$","BAND$","MWh","NMI","V$"]},"MARKETFEETYPE":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":false,"comment":"Type - MW or $","examples":["ALL","CUSTOMER","GENERATOR","IRP","MARKET"]},"METER_SUBTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Meter Sub Type values are ACE, ASOE or ALL. ACE represent ACE_MWH value , ASOE represent ASOE_MWH value and ALL represent sum of ACE_MWh and ASOE_MWh","examples":["ACE","ALL","ASOE"]},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Energy Type for the Market Fees Calculation. E.g of Meter Types are CUSTOMER, GENERATOR, NREG, BDU etc. If Meter Type is mentioned as ALL then all the Meter Types for that Participant Category will be used in the Fee calculation","examples":["ALL","BDU","CUSTOMER"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETFEE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":2275,"decompressed_size_all_time":2138690},"visibility":"Public","trigger":"When fees change"},"MARKETFEEDATA":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKETFEEDATA","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#49"],"comment":"MARKETFEEDATA sets out actual fee rates, as adjusted from time to time.","description":"MARKETFEEDATA is public data, and is available to all participants.\n\nSource\n\nMARKETFEEDATA updates whenever fee rates change.","primary_keys":["EFFECTIVEDATE","MARKETFEEID","MARKETFEEVERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date on which this data becomes effective","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for Market Fee","examples":["F_5MSGS_WP","F_ADMIN","F_ALO_GEN","F_ALO_MG","F_ALO_MSG","F_ALO_WP","F_COMA_REV","F_CYB_WP","F_DER_WP","F_EST_NECA","F_EST_NEMM","F_EUA_NECA","F_FRC","F_GEN_NECA","F_GEN_NEMM","F_GEN_REV","F_MG_REV","F_MSG_REV","F_NEM25WP","F_PAR_COMA","F_SVC_IT","MC_5MS_AC1","MC_5MS_AC2","MC_5MS_AS1","MC_5MS_AS2","MC_5MS_CP","MC_COR_AC1","MC_COR_AC2","MC_COR_AS1","MC_COR_AS2","MC_COR_CP","MC_CYB_AC1","MC_CYB_AC2","MC_CYB_AS1","MC_CYB_AS2","MC_CYB_CP","MC_ECA_CP","MC_REF_AC1","MC_REF_AC2","MC_REF_AS1","MC_REF_AS2","MC_REF_CP","MC_RET_CP","V_5MGS_CP2","V_5MGS_MC2","V_5MGS_MC3","V_5MSGS_CP","V_5MSGS_MC","V_ADMIN","V_ALO_CP","V_ALO_CP2","V_ALO_CUS2","V_ALO_CUS3","V_ALO_CUST","V_CUST_NSM","V_CUST_NTP","V_CYB_CP","V_CYB_CP2","V_CYB_MC","V_CYB_MC2","V_CYB_MC3","V_DER_CP","V_DER_CP2","V_DER_MC","V_DER_MC2","V_DER_MC3","V_ECA","V_ECA2","V_ECA3","V_EST","V_EST_FRC","V_EST_NECA","V_EST_NEMM","V_EUA","V_EUA_NECA","V_FRC","V_FRC_CUS2","V_FRC_CUS3","V_FRC_CUST","V_GEN_CP","V_GEN_CP2","V_GEN_FRC","V_GEN_NECA","V_GEN_NEM2","V_GEN_NEM3","V_GEN_NEMM","V_METERING","V_NECA","V_NEM25CP","V_NEM25CP2","V_NEM25MC","V_NEM25MC2","V_NEM25MC3","V_NEMMCO","V_NET_NECA","V_PAR_COMA","V_PAR_COMP","V_PW_SYSOP","V_SETT","WP_5MS","WP_COR","WP_CYB","WP_PCF","WP_REF"]},"MARKETFEEVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Version of fees for this id","examples":["1","2"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/08/18 11:28:28"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEVALUE":{"sql_type":"NUMBER(22,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Market fee rate/MWh, a dollar amount","examples":["0.0003","0","25","0.42039"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETFEEDATA%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":5317,"decompressed_size_all_time":5599890},"visibility":"Public","trigger":"When fees change"},"MARKETFEETRK":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKETFEETRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#58"],"comment":"MARKETFEETRK sets out versions of each market fee used and its effective date.","description":"MARKETFEETRK data is public, so is available to all participants.\n\nSource\n\nMARKETFEETRK updated infrequently, when new annual rates must be\ninserted.\n\nVolume\n\nOne record inserted per year.","primary_keys":["EFFECTIVEDATE","MARKETFEEVERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective Date of Market notice","examples":["1998/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"MARKETFEEVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Version of fees for this ID","examples":["1","2"],"is_integer":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["AJENSZ","APHANDANOUVONG","BNELSON","DBOTHA","DGATTY","JGU","JWORMALD","LINDAM","SBUGGY","SCOTT","SEANB","TREILLY","VONNYW","WING"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2001/06/26 15:03:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/08/18 11:28:42"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETFEETRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1249,"decompressed_size_all_time":1467070},"visibility":"Public","trigger":"When new annual rates are added."},"MARKETNOTICEDATA":{"package":"MARKET_NOTICE","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_NOTICE","REPORT_SUB_TYPE":"MARKETNOTICEDATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec35.htm#1"],"comment":"MARKETNOTICEDATA shows market notices data provided to all participants (market) and specific participants (participant).","description":"MARKETNOTICEDATA data is confidential to each participant, although some\nnotices are sent to all participants.\n\nSource\n\nMARKETNOTICEDATA updates immediately available.","primary_keys":["NOTICEID"],"indexes":[["LASTCHANGED"]],"columns":{"NOTICEID":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Notice Identifier","examples":["117253","117516"],"is_integer":true,"num_int_bits":64},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Effective Date of Market notice","examples":["2024/07/01 08:44:55"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EXTERNALREFERENCE":{"sql_type":"VARCHAR2(255)","pl_type":"str","mandatory":false,"comment":"External Reference for extra data pertaining to market notice","examples":["Actual Lack Of Reserve Level 1 (LOR1) in the NSW region - 03/07/2024","Actual Lack Of Reserve Level 1 (LOR1) in the SA region - 30/07/2024","CHG0090456 | Completed | Production | Renewal and update of AEMO's FBS_Prod_Hub.aemo.com.au server certificate","CHG0090458 | Completed | Production | Planned Maintenance to Brisbane Internet firewall.","CHG0090458 | Production | Planned Maintenance to Brisbane Internet firewall.","CHG0090717 | Cancelled | Production | NSW Marketnet Router Replacement","CHG0090717 | Production | NSW Marketnet Router Replacement","CHG0090718 | Cancelled | Production | QLD Marketnet Router Replacement","CHG0090718 | Production | QLD Marketnet Router Replacement","CHG0090719 | Cancelled | Production | Change to MarketNet SSL VPN","CHG0090719 | Production | Change to MarketNet SSL VPN","CHG0090731 | Production | MSATS and eMDM July Maintenance Release","CHG0090790 | Completed | Production | Maintenance activities to be performed on the  Gas Short Term Trading Market Systems Production.","CHG0090827 | Completed | Production | Identity Service Config Update in Production.","CHG0090827 | Production | Identity Service Config Update in Production.","CHG0091021 | Completed | Pre-Production | Pre-Prod MSATS 53.1.1 Patch Maintenance Release","CHG0091021 | Pre-Production | Pre-Prod MSATS 53.1.1 Patch Maintenance Release","CHG0091273 | Completed | Pre-Production | Pre-Prod MASTS - eMDM  Maintenance AKS v1.28 upgrade","CHG0091273 | Pre-Production | Pre-Prod MASTS - eMDM  Maintenance AKS v1.28 upgrade","CHG0091275 | Completed | Production | MSATS - eMDM Maintenance AKS v1.28 upgrade","CHG0091275 | Production | MSATS - eMDM Maintenance AKS v1.28 upgrade","CHG0091507 | Production | As part of the Platform Services Patching Program, webMethods Inactive Production Application Servers in Brisbane will have critical s","CHG0091533 | Completed | Production | Planned Outage for the Gas Short Term Trading Market Systems Production.","CHG0091533 | Production | Planned Outage for the Gas Short Term Trading Market Systems Production.","Cancellation - AEMO Intervention Event - SA region 05/07/2024","Cancellation - AEMO Intervention Event - SA region 15/07/2024","Cancellation - AEMO Intervention Event - SA region 18/07/2024","Cancellation - AEMO Intervention Event - SA region 19/07/2024","Cancellation - AEMO Intervention Event - SA region 20/07/2024","Cancellation - AEMO Intervention Event - SA region 21/07/2024","Cancellation - AEMO Intervention Event - SA region 22/07/2024","Cancellation - AEMO Intervention Event - SA region 24/07/2024","Cancellation - AEMO Intervention Event - SA region 25/07/2024","Cancellation - AEMO Intervention Event - SA region 26/07/2024","Cancellation - Load Restoration Direction in the NSW Region - 08/07/2024","Cancellation - Possible intervention to manage power system security in SA region 05/07/2024","Cancellation -Inter-regional transfer limit variation - constraint automation to manage Power System Security in NSW region - 08/07/2024","Cancellation Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region).","Cancellation Inter-Regional Transfer limit variation - Murraylink control unavailable (VIC Region)","Cancellation of Actual (LOR1) condition in the NSW region - 03/07/2024","Cancellation of Actual (LOR1) condition in the SA region - 30/07/2024","Cancellation of Reclassification of a Non-Credible Contingency Event - SA region - 13/10/2023","Cancellation of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.","Cancellation of a Non-Credible Contingency Event: Bannaby - Mt Piper 5A6 500kV line and Bannaby - Mt Piper 5A7 500kV line in NSW1 due to Lightning.","Cancellation of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.","Cancellation of a Non-Credible Contingency Event: Eildon PS - Mt Beauty No.1 220 kV line and Eildon PS - Mt Beauty No.2 220 kV line in VIC1 due to Lightning.","Cancellation of a Non-Credible Contingency Event: Farrell - Reece No.1 220 kV line and Farrell - Reece No.2 220 kV line in TAS1 due to Lightning.","Cancellation of a Non-Credible Contingency Event: Farrell-John Butters line and Farrell-Rosebery-Newton-Queenstown line in TAS1 due to Lightning.","Cancellation of the reclassification of a Non-Credible Contingency Event: Brinkworth-Davenport, Brinkworth-Templers West and Para-Templers West 275kV lines in SA due to severe weather warning .","Cancellation of the reclassification of a Non-Credible Contingency Event: Para-Templers West and Magill-Torrens Island A 275kV lines in SA due to severe weather warning.","Cancellation: Direction issued to:  AGL SA Generation Pty Limited - TORRB2 TORRENS ISLAN","Cancellation: Direction issued to:  AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN","Cancellation: Direction issued to:  AGL SA Generation Pty Limited - TORRB4 TORRENS ISLAN","Cancellation: Reclassification of non-credible contingency event due to existence of widespread abnormal conditions - SA region.","Cancellation: Reclassification of non-credible contingency event due to existence of widespread abnormal conditions - South Australia and Victoria regions.","Correction - Non-credible contingency event - QLD region - 27/07/2024","Direction - SA region 05/07/2024","Direction - SA region 15/07/2024","Direction - SA region 18/07/2024","Direction - SA region 19/07/2024","Direction - SA region 20/07/2024","Direction - SA region 21/07/2024","Direction - SA region 22/07/2024","Direction - SA region 23/07/2024","Direction - SA region 24/07/2024","Direction - SA region 25/07/2024","Direction - SA region 26/07/2024","Direction - SA region 31/07/2024","Foreseeable AEMO intervention under clause 4.8.5A (a) of the NER in SA region","Increase to QNI limit to next hold point of 1400 MW Qld to NSW","Inter-Regional Transfer limit variation - Directlink - NSW Region","Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region)","Inter-Regional Transfer limit variation - Murraylink control unavailable (VIC Region)","Inter-regional transfer limit variation - 89 Lismore - Coffs 330kV Line - NSW region - 08/07/2024","Inter-regional transfer limit variation - Armidale Coffs Harbour 96C 132kV LINE - NSW region - 20/07/2024","Inter-regional transfer limit variation - Coffs Harbour - Lismore (89) 330kV line - NSW region - 10/07/2024","Inter-regional transfer limit variation - Crookwell- Gullen Range 3H and Bannaby - Crookwell 61 330 kV lines - NSW region - 04/07/2024","Inter-regional transfer limit variation - Eraring - Newcastle 90 330kV Line - NSW region - 08/07/2024","Inter-regional transfer limit variation - Heywood - South East 1 275 kV Line - SA region - 22/07/2024","Inter-regional transfer limit variation - Heywood - South East No 2 275 kV Line  - SA region - 26/07/2024","Inter-regional transfer limit variation - Heywood M1 Transformer - VIC region - 25/07/2024","Inter-regional transfer limit variation - Heywood interconnector - SA and Vic regions - 19/07/2024","Inter-regional transfer limit variation - Keilor - Sth Morang 500kV Line - VIC region - 25/07/2024","Inter-regional transfer limit variation - Mitchell Singleton 95X 132kV LINE- NSW region - 20/07/2024","Inter-regional transfer limit variation - Robertstown - Tungkillo No.1 275 kV line - SA region - 12/07/2024","Inter-regional transfer limit variation - [outage element] - NSW region - 04/07/2024","Inter-regional transfer limit variation - constraint automation to manage Power System Security in NSW region - 08/07/2024","Inter-regional transfer limit variation -Murraylink - SA region - 06/07/2024","Inter-regional transfer limit variation -Tungkillo-Tailem_Bnd 1 275kV LINE - SA region - 16/07/2024","Load Restoration Direction in the NSW Region","Load Shedding Direction in the NSW Region","NON-CONFORMANCE Region NSW1 Monday, 1 July 2024","NON-CONFORMANCE Region NSW1 Tuesday, 2 July 2024","NON-CONFORMANCE Region NSW1 Tuesday, 23 July 2024","NON-CONFORMANCE Region NSW1 Wednesday, 31 July 2024","NON-CONFORMANCE Region QLD1 Friday, 12 July 2024","NON-CONFORMANCE Region QLD1 Monday, 1 July 2024","NON-CONFORMANCE Region QLD1 Saturday, 20 July 2024","NON-CONFORMANCE Region QLD1 Saturday, 6 July 2024","NON-CONFORMANCE Region QLD1 Sunday, 14 July 2024","NON-CONFORMANCE Region QLD1 Sunday, 7 July 2024","NON-CONFORMANCE Region QLD1 Wednesday, 24 July 2024","NON-CONFORMANCE Region QLD1 Wednesday, 3 July 2024","NON-CONFORMANCE Region SA1 Saturday, 6 July 2024","NON-CONFORMANCE Region VIC1 Sunday, 14 July 2024","Network Augmentation Commissioned - VIC Region - 18/07/2024","Network Augmentation Commissioned - VIC Region - 30/07/2024","Non-credible contingency event - QLD region - 27/07/2024","Non-credible contingency event - QLD region - 30/07/2024","PDPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region [beginning] on 01/07/2024","PDPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region [beginning] on 29/07/2024","PDPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 02/07/2024","PDPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 03/07/2024","PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region on 03/07/2024","PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 01/07/2024","PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 02/07/2024","PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 03/07/2024","PDPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 29/07/2024","PDPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 3/07/2024","Possible intervention to manage power system security in SA Region","RESERVE NOTICE MT PASA PUBLICATION 16 July 2024","RESERVE NOTICE MT PASA PUBLICATION 2 July 2024","RESERVE NOTICE MT PASA PUBLICATION 23 July 2024","RESERVE NOTICE MT PASA PUBLICATION 30 July 2024","RESERVE NOTICE MT PASA PUBLICATION 9 July 2024","Reclassification of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Bannaby - Mt Piper 5A6 500kV line and Bannaby - Mt Piper 5A7 500kV line in NSW1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Brinkworth-Davenport, Brinkworth-Templers West and Para-Templers West 275kV lines in SA due to severe weather warning.","Reclassification of a Non-Credible Contingency Event: Eildon PS - Mt Beauty No.1 220 kV line and Eildon PS - Mt Beauty No.2 220 kV line in VIC1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Farrell - Reece No.1 220 kV line and Farrell - Reece No.2 220 kV line in TAS1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Farrell-John Butters line and Farrell-Rosebery-Newton-Queenstown line in TAS1 due to Lightning.","Reclassification of a Non-Credible Contingency Event: Para-Templers West and Magill-Torrens Island A 275kV lines in SA due to severe weather warning.","Reclassification of non-credible contingency event due to existence of widespread abnormal conditions - SA region.","Reclassification of non-credible contingency event due to existence of widespread abnormal conditions - South Australia and Victoria regions.","STPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 30/07/2024","STPASA - Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 31/07/2024","STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 03/07/2024","STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 29/07/2024","STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 30/07/2024","STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 31/07/2024","STPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 29/07/2024","STPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 30/07/2024","STPASA - Update of the Forecast Lack Of Reserve Level 1 (LOR1) in the TAS Region on 31/07/2024","Update - Direction - SA Region - 05/07/2024","Update - Direction - SA region 05/07/2024","Update - Foreseeable AEMO intervention in SA region","Update - Non-credible contingency event - QLD region - 27/07/2024","Update - Non-credible contingency event - QLD region - 30/07/2024","Update - Possible intervention to manage power system security in SA region","Update Direction - AGL SA Generation Pty Limited - TORRB2 TORRENS ISLAN","Update Direction - AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN","Update Direction - AGL SA Generation Pty Limited - TORRB4 TORRENS ISLAN","Update Direction - SA region 21/07/2024","Update Direction - SA region 25/07/2024","[EventId:202407031730_NRM_NSW1_VIC1_started] NEGRES CONSTRAINT NRM_NSW1_VIC1 started operating from 03 July 2024 17:30","[EventId:202407031755_NRM_NSW1_VIC1_stopped] NEGRES CONSTRAINT NRM_NSW1_VIC1 ceased operating from 03 July 2024 17:55","[EventId:202407201330_NRM_VIC1_NSW1_started] NEGRES CONSTRAINT NRM_VIC1_NSW1 started operating from 20 July 2024 13:30","[EventId:202407201430_NRM_VIC1_NSW1_stopped] NEGRES CONSTRAINT NRM_VIC1_NSW1 ceased operating from 20 July 2024 14:30","[EventId:202407251000_NRM_VIC1_NSW1_started] NEGRES CONSTRAINT NRM_VIC1_NSW1 started operating from 25 July 2024 10:00","[EventId:202407251115_NRM_VIC1_NSW1_stopped] NEGRES CONSTRAINT NRM_VIC1_NSW1 ceased operating from 25 July 2024 11:15","[EventId:202407300730_NRM_VIC1_NSW1_started] NEGRES CONSTRAINT NRM_VIC1_NSW1 started operating from 30 July 2024 07:30","[EventId:202407300755_NRM_VIC1_NSW1_stopped] NEGRES CONSTRAINT NRM_VIC1_NSW1 ceased operating from 30 July 2024 07:55"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2024/07/01 08:44:55"],"parse_csv_as_string":true,"is_s_datetime":true},"NOTICETYPE":{"sql_type":"VARCHAR2(25)","pl_type":"pl.Categorical","mandatory":false,"comment":"Market Notice Type","examples":["MARKET"]},"REASON":{"sql_type":"VARCHAR2(2000)","pl_type":"str","mandatory":false,"comment":"Detail of market notices.","examples":["QUVNTyBFTEVDVFJJQ0lUWSBNQVJLRVQgTk9USUNFDQoNClRoZSBGb3JlY2FzdCBMT1IxIGNvbmRpdGlvbiBpbiB0aGUgVEFTIHJlZ2lvbiBhZHZpc2VkIGluIEFFTU8gRWxlY3RyaWNpdHkgTWFya2V0IE5vdGljZSBOby4gMTE3MjU5IGlzIGNhbmNlbGxlZCBhdCAxNjQ1IGhycyAwMS8wNy8yMDI0DQogDQpNYW5hZ2VyIE5FTSBSZWFsIFRpbWUgT3BlcmF0aW9ucw==","QUVNTyBFTEVDVFJJQ0lUWSBNQVJLRVQgTk9USUNFDQoNClRoZSBGb3JlY2FzdCBMT1IxIGNvbmRpdGlvbiBpbiB0aGUgVEFTIHJlZ2lvbiBhZHZpc2VkIGluIEFFTU8gRWxlY3RyaWNpdHkgTWFya2V0IE5vdGljZSBOby4gMTE3MjY5IGlzIGNhbmNlbGxlZCBhdCAwODIwIGhycyAwMi8wNy8yMDI0LiAgIA0KIA0KTWFuYWdlciBORU0gUmVhbCBUaW1lIE9wZXJhdGlvbnM="],"warnings":["This column may be base64 encoded, because the raw values may contain newlines."],"base64_encoded":true},"TYPEID":{"sql_type":"VARCHAR2(25)","pl_type":"str","mandatory":false,"comment":"Market Notice Type Identifier (Market - all participants. Participant - selected participants)","examples":["GENERAL NOTICE","INTER-REGIONAL TRANSFER","LOAD RESTORE","LOAD SHED","MARKET INTERVENTION","MARKET SYSTEMS","NON-CONFORMANCE","POWER SYSTEM EVENTS","RECLASSIFY CONTINGENCY","RESERVE NOTICE","SETTLEMENTS RESIDUE"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MARKETNOTICEDATA_202407010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":7},"compressed_size_per_month":44888,"decompressed_size_all_time":81321220},"visibility":"Private & Public","warnings":[{"msg":"The `REASON` column may contain paragraphs of text with quoted newlines, so one CSV row may span multiple text lines. Be careful when reading the CSV. (Tell your library that `\"` is the quote character.) Recently, AEMO has started BASE64 encoding the column, which is great. However, the versions which are BASE64 encoded and the versions that are not are both marked as version 1 in the 4th metadata column. So depending on when and where you downloaded the file from, you may need to base64 decode, or maybe not. See more in [the guide](../../guide/preprocessing.md#special-characters).\n","category":"parsing"}],"trigger":"When a Market Notice is issued."},"MARKETNOTICETYPE":{"package":"MARKET_NOTICE","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_NOTICE","REPORT_SUB_TYPE":"MARKETNOTICETYPE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec35.htm#10"],"comment":"MARKETNOTICETYPE sets out the different types of market notices (e.g. market systems).","description":"MARKETNOTICETYPE data is public, so is available to all participants.\n\nSource\n\nMARKETNOTICETYPE updates whenever market notice types change.","primary_keys":["TYPEID"],"indexes":[["LASTCHANGED"]],"columns":{"TYPEID":{"sql_type":"VARCHAR2(25)","pl_type":"str","mandatory":true,"comment":"Identifier for market notice type","examples":["ADMINISTERED PRICE CAP","CONSTRAINTS","FORCED MAJEURE","GENERAL NOTICE","INTER-REGIONAL TRANSFER","LOAD RESTORE","LOAD SHED","MANDATORY RESTRICTIONS","MARKET DIRECTION","MARKET INTERVENTION","MARKET SUSPENSION","MARKET SYSTEMS","MINIMUM SYSTEM LOAD","MPDI","NEM SYSTEMS","NON-CONFORMANCE","POWER SYSTEM EVENTS","POWER SYSTEM SECURITY","PRICE ADJUSTMENT","PRICES SUBJECT TO REVIEW","PRICES UNCHANGED","PROCESS INVESTIGATION","PROCESS REVIEW","PROTECTED EVENT","RECALL GEN CAPACITY","RECLASSIFY CONTINGENCY","RESERVE NOTICE","SETTLEMENTS RESIDUE","SYSTEM RECONFIGURATION","SYSTEM RESTART","TEST","TRAIN","VOLL"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Type description","examples":["Administered price periods declared.","Declaration/Cancellation; MR Schedule; Offers","Details of Non-conformance/Conformance","Discontinued 24/09/2001- Process Investigation: Scheduling Error","Dispatch Price is VOLL","Emergency events/conditions","Impact of System Reconfiguration","Inter-Regional Transfer limit variation","LRC/LOR1/LOR2/LOR3","MMS, EMS, SCADA, IT, BIDDING","MSL1/MSL2/MSL3","Management of Negative Residues","Market suspended in region(s).","NEL 116 Direction","New/Modified Constraints","Not applicable from 09/12/2002","Not applicable from 31/12/2000. (Administered Price Period/Cap)","Overconstrained Dispatch","Please double click on (Memo) in the reason column","Prices are not firm due to an MII or OCD event","Prices have been reviewed and remain unchanged","Prices have been reviewed and were adjusted","Process Review","Protected Event","Recall Gen Capacity","Reclassify contingency events","Reserve Contract / Direction / Instruction","Status of Market Systems","Subjects not covered in specific notices","Training/Testing Notice"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:01:21"],"parse_csv_as_string":true,"is_s_datetime":true},"RAISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Not used","examples":["AEMO","NEMMCO","RSO"],"unused":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETNOTICETYPE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1638,"decompressed_size_all_time":2175560},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"When market notice types change"},"MARKETSUSPENSION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKETSUSPENSION","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#532"],"comment":"MARKETSUSPENSION is obsolete from 2017 End of Year DM4.27 Release.\nMARKETSUSPENSION sets out a start and end periods of any market suspension and the reason.","description":"MARKETSUSPENSION is public data, so is available to all participants.\n\nSource\n\nMARKETSUSPENSION updates only if market is suspended.","unused":true,"primary_keys":["SUSPENSIONID"],"indexes":[["LASTCHANGED"]],"columns":{"SUSPENSIONID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Unique identifier for suspension","examples":["SA BLACK ","Y2KCAP"]},"ENDAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising end","examples":["CBROWNLEE","RGILLETT"]},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"End Date of suspension","examples":["2000/01/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"End trading interval of suspension","examples":["0","45"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1999/12/30 19:10:46"],"parse_csv_as_string":true,"is_s_datetime":true},"REASON":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Reason for suspension","examples":["System Black & Ministerial Direction ","Y2K Price Cap during 3 day Y2K Period 31/12/1999 to 02/01/2000"]},"STARTAUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising start","examples":["CBROWNLEE","RGILLETT"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Start date of suspension","examples":["1999/12/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Start trading interval of suspension","examples":["1","33"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETSUSPENSION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":596,"decompressed_size_all_time":775640},"visibility":"Public","trigger":"When the market is suspended"},"MARKETSUSREGION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKETSUSREGION","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#541"],"comment":"MARKETSUSREGION is obsolete from 2017 End of Year DM4.27 Release.\nMARKETSUSREGION sets out a regions affected by a market suspension.","description":"MARKETSUSREGION is public data, so is available to all participants.\n\nSource\n\nMARKETSUSREGION updates only if market is suspended.","unused":true,"primary_keys":["REGIONID","SUSPENSIONID"],"indexes":[["LASTCHANGED"]],"columns":{"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SUSPENSIONID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Unique identifier of suspension","examples":["SA BLACK ","Y2KCAP"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1999/12/30 19:10:13"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKETSUSREGION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":443,"decompressed_size_all_time":576460},"visibility":"Public","trigger":"When the market is suspended"},"MARKET_FEE_CAT_EXCL":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKET_FEE_CAT_EXCL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#10"],"comment":"Market fee exclusions for participant categories.","primary_keys":["EFFECTIVEDATE","MARKETFEEID","PARTICIPANT_CATEGORYID","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date the exclusion is effective from","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The excluded market fee"},"PARTICIPANT_CATEGORYID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Participant category to be excluded from this market fee"},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The version information for this record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"When there is a market fee exclusion"},"MARKET_FEE_CAT_EXCL_TRK":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKET_FEE_CAT_EXCL_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#16"],"comment":"Tracking table for market fee exclusions for participant categories.","primary_keys":["EFFECTIVEDATE","MARKETFEEID","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date the exclusion is effective from","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The excluded market fee"},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The version information for this record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"When there is a market fee exclusion"},"MARKET_FEE_EXCLUSION":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKET_FEE_EXCLUSION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#22"],"comment":"MARKET_FEE_EXCLUSION shows the list of market fees from which a participant is excluded from funding after a particular settlement date.","description":"MARKET_FEE_EXCLUSION data is confidential to the relevant participant.\n\nSource\n\nMARKET_FEE_EXCLUSION updates only on change of participant\nconfiguration.","primary_keys":["EFFECTIVEDATE","MARKETFEEID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date on which this data becomes effective","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for Market Fee"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of fees for this ID","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When there is a participant configuration change"},"MARKET_FEE_EXCLUSIONTRK":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"MARKET_FEE_EXCLUSION_TRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#31"],"comment":"MARKET_FEE_EXCLUSIONTRK shows authorisation details of participant market fee exclusion data sets.","description":"MARKET_FEE_EXCLUSIONTRK is confidential to the participant.\n\nSource\n\nMARKET_FEE_EXCLUSIONTRK updates only on change of participant\nconfiguration.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date on which this data becomes effective","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of fees for this ID","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When there is a participant configuration change"},"MARKET_PRICE_THRESHOLDS":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"MARKET_PRICE_THRESHOLDS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#91"],"comment":"MARKET_PRICE_THRESHOLDS sets out the market cap , floor and administered price thresholds applying to the electricity market","description":"MARKET_PRICE_THRESHOLDS data is public, so is available to all\nparticipants.\n\nSource\n\nMARKET_PRICE_THRESHOLDS only changes when a change is made to a market\nprice threshold. This table changes infrequently.","primary_keys":["EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date that this record becomes effective","examples":["1997/11/04 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"version no for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADMINISTERED_PRICE_THRESHOLD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Threshold value beyond which Aggregate Prices per Region over 336 Trade Intervals (Energy), or 2016 Dispatch Intervals (FCAS), will result in an Administered Price declaration","examples":["150000","2225900"],"is_float":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"user authorising","examples":["LUKEB","NORRIS","PSS","TOM"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"date data authorised","examples":["2002/03/25 08:34:36"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:01:36"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETPRICEFLOOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The floor price that the spot market price will not fall below.","examples":["-1000"],"is_float":true},"VOLL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"value of lost load if total supply falls short of demand after load management then involuntary load","examples":["5000","23200"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKET_PRICE_THRESHOLDS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":917,"decompressed_size_all_time":1031980},"visibility":"Public","trigger":"When there is a market price threshold change"},"MARKET_SUSPEND_REGIME_SUM":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKET_SUSPEND_REGIME_SUM","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#35"],"comment":"Tracks the evolution of pricing regimes applied to the suspended region and from which Dispatch Interval","description":"MARKET_SUSPEND_REGIME_SUM is public data, so is available to all\nparticipants.","primary_keys":["REGIONID","START_INTERVAL","SUSPENSION_ID"],"columns":{"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region(s) covered by this evolution of the event","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"First Dispatch interval from which this regime applies","examples":["2022/02/18 14:25:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SUSPENSION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for this suspension event","examples":["202202181425.1","202603231145.1"]},"END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last Dispatch interval for which this regime applies","examples":["2022/06/23 04:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2022/02/18 14:21:34"],"parse_csv_as_string":true,"is_s_datetime":true},"PRICING_REGIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Pricing Regime applied","examples":["DISPATCH","SCHEDULE"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKET_SUSPEND_REGIME_SUM%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":743,"decompressed_size_all_time":188610},"visibility":"Public","trigger":"Market suspension"},"MARKET_SUSPEND_REGION_SUM":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKET_SUSPEND_REGION_SUM","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#42"],"comment":"Summary of Market Suspension timings","description":"MARKET_SUSPEND is public data, so is available to all participants.","primary_keys":["REGIONID","SUSPENSION_ID"],"columns":{"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region(s) covered by the Suspension event","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SUSPENSION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for this suspension event","examples":["202202181425.1","202603231145.1"]},"END_REGION_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last Dispatch interval for the Suspension event for this Region","examples":["2022/02/18 16:10:00"],"parse_csv_as_string":true,"is_s_datetime":true},"END_SUSPENSION_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last Dispatch interval for the Suspension event","examples":["2022/02/18 16:10:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INITIAL_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Initial interval of the Suspension event","examples":["2022/02/18 14:25:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last DateTime the Suspension was administered","examples":["2022/02/18 15:38:41"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKET_SUSPEND_REGION_SUM%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":689,"decompressed_size_all_time":173420},"visibility":"Public","trigger":"Creation of market suspension"},"MARKET_SUSPEND_SCHEDULE":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKET_SUSPEND_SCHEDULE","VERSION":1},{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKET_SUSPEND_SCHEDULE","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#49"],"comment":"Trading prices that will apply in the event of a market suspension event updated weekly.","description":"MARKET_SUSPEND_SCHEDULE is public data, so is available to all\nparticipants.","primary_keys":["DAY_TYPE","EFFECTIVEDATE","PERIODID","REGIONID"],"columns":{"DAY_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Distinguishes which record set to apply - at time of writing this was Business or Non-business day but may change in the future depending on outcome of consultation","examples":["BUS_DAY","NON_BUS_DAY"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date from when this record set is effective","examples":["2017/12/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"48 intervals for a day, midnight base (equates to 00:30 - 00:00)","examples":["1","48"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region affected.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"ENERGY_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy Price applied for this period for this Day Type","examples":["27.2","60","1184.65","106"],"is_float":true},"L1_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 1Sec contingency Price applied for this period for this Day Type","is_float":true},"L5_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5Min contingency Price applied for this period for this Day Type","examples":["0.04","1","1.9"],"is_float":true},"L6_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6Sec contingency Price applied for this period for this Day Type","examples":["0.01","0","10.7"],"is_float":true},"L60_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60Sec contingency Price applied for this period for this Day Type","examples":["0.01","0","2","17.75"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2017/12/18 11:49:38"],"parse_csv_as_string":true,"is_s_datetime":true},"LREG_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation Price applied for this period for this Day Type","examples":["6.77","15","58.52","22"],"is_float":true},"R1_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 1Sec contingency Price applied for this period for this Day Type","is_float":true},"R5_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5Min contingency Price applied for this period for this Day Type","examples":["1.3","2","16.96","12"],"is_float":true},"R6_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6Sec contingency Price applied for this period for this Day Type","examples":["0.99","7","390.08","51"],"is_float":true},"R60_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60Sec contingency Price applied for this period for this Day Type","examples":["0.67","1","268.04","7"],"is_float":true},"RREG_RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation contingency Price applied for this period for this Day Type","examples":["10.71","17","132.85","28"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKET_SUSPEND_SCHEDULE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":4508085,"decompressed_size_all_time":1049718120},"visibility":"Public","trigger":"Weekly and ad hoc"},"MARKET_SUSPEND_SCHEDULE_TRK":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"MARKET_SUSPEND_SCHEDULE_TRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#56"],"comment":"Parent table for pricing regimes used in suspensions","primary_keys":["EFFECTIVEDATE"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date from when this record set is effective","examples":["2017/12/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"DateTime this record set was loaded","examples":["2017/12/18 11:49:38"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"COMMENTS":{"sql_type":"VARCHAR2(1000)","pl_type":"str","mandatory":false,"comment":"Reason why this regime was applied"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2017/12/18 11:49:38"],"parse_csv_as_string":true,"is_s_datetime":true},"SOURCE_END_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"End Date of the date range for the source data","examples":["2017/12/10 00:00:00"],"parse_csv_as_string":true,"is_date":true},"SOURCE_START_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Start Date of the date range for the source data","examples":["2017/11/12 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MARKET_SUSPEND_SCHEDULE_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":8711,"decompressed_size_all_time":2000770},"visibility":"Public","trigger":"Market suspension"},"MAS_CP_CHANGE":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64.htm#550","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec64_1.htm"],"comment":"MAS_CP_CHANGE records pending changes to the current MAS configuration.","description":"Obsolete; Replaced by MSATS\n\nSource\n\nMAS_CP_CHANGE updates daily with each MAS export.\n\nNote\n\nExpiry date: When the Expiry date on a change record is reached, the\nchange record is deleted.\n\nMeter Read Date: only used in specific circumstances. For more details,\nrefer to MAS documentation. The meter read date is not cleared if it\nbecomes unusable (e.g. due to change of Metering Type or the passage of\ntime).","unused":true,"primary_keys":["NMI"],"indexes":[["LASTCHANGED"]],"columns":{"NMI":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"National Metering Identifier"},"AGGREGATE_DATA":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Aggregate data Flag (YIN)","is_boolean":true},"AVERAGE_DAILY_LOAD_KWH":{"sql_type":"NUMBER(8,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Average Daily load in KWh","is_integer":true,"num_int_bits":32},"CITY_SUBURB":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point City/Suburb"},"CP_DETAIL_1":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point detail 1"},"CP_DETAIL_2":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point detail 2"},"CP_NAME":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point name"},"CP_NEW_SECURITY_CODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"New Security Code"},"CP_OLD_SECURITY_CODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Old Security Code"},"CREATE_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Set by the system with today's date when the change record is created.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CURRENT_CHANGE_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Current change date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DISTRIBUTION_LOSS":{"sql_type":"NUMBER(5,4)","pl_type":"pl.Float64","mandatory":false,"comment":"Distribution loss factors","is_float":true},"EXPIRY_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Set by the system (and cannot be changed).","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INITIAL_CHANGE_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Initial change date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"JURISDICTION":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":false,"comment":"Area; for application of rules"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"METER_READ_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of meter reading","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"METERING_TYPE":{"sql_type":"VARCHAR2(9)","pl_type":"pl.Categorical","mandatory":false,"comment":"Type of metering installation (e.g. BASIC, MRIM, COMMS)"},"NEW_FINANCIAL_PARTICIPANT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New FRMP"},"NEW_FRMP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New FRMP approval flag","is_boolean":true},"NEW_FRMP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New FRMP text field"},"NEW_LNSP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New LNSP approval flag","is_boolean":true},"NEW_LOCAL_NETWORK_PROVIDER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New Local Network Provider"},"NEW_LOCAL_RETAILER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New Local Retailer"},"NEW_LR_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New LR approval flag","is_boolean":true},"NEW_LR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New LR text field"},"NEW_LSNP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New LNSP text field (LNSP misspelt in name)"},"NEW_MDA_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New MDA approval flag","is_boolean":true},"NEW_MDA_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New MDA text field"},"NEW_METERING_DATA_AGENT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New Metering Data Agent"},"NEW_RESPONSIBLE_PERSON":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New Responsible Person"},"NEW_RETAILER_OF_LAST_RESORT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"New Retailer of Last Resort"},"NEW_ROLR_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New ROLR approval flag","is_boolean":true},"NEW_ROLR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New ROLR text field"},"NEW_RP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"New RP approval flag","is_boolean":true},"NEW_RP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"New RP text field"},"NMI_CLASS":{"sql_type":"VARCHAR2(9)","pl_type":"str","mandatory":false,"comment":"Class of National Metering Identifier to allow for different business rules to apply"},"OLD_FINANCIAL_PARTICIPANT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old FRMP"},"OLD_FRMP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old FRMP approval flag","is_boolean":true},"OLD_FRMP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old FRMP text field"},"OLD_LNSP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old LNSP approval flag","is_boolean":true},"OLD_LOCAL_NETWORK_PROVIDER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old Local Network Provider"},"OLD_LOCAL_RETAILER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old Local Retailer"},"OLD_LR_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old LR approval flag","is_boolean":true},"OLD_LR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old LR text field"},"OLD_LSNP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old LNSP text field (LNSP misspelt in name)"},"OLD_MDA_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old MDA approval flag","is_boolean":true},"OLD_MDA_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old MDA text field"},"OLD_METERING_DATA_AGENT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old Metering Data Agent"},"OLD_RESPONSIBLE_PERSON":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old Responsible Person"},"OLD_RETAILER_OF_LAST_RESORT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Old Retailer of Last Resort"},"OLD_ROLR_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old ROLR approval flag","is_boolean":true},"OLD_ROLR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old ROLR text field"},"OLD_RP_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Old RP approval flag","is_boolean":true},"OLD_RP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Old RP text field"},"POST_CODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Connection point postcode"},"PRUDENTIAL_OK":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Prudential check flag","is_boolean":true},"STATE":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":false,"comment":"State of Australia"},"STATUS_FLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Active/Inactive flag","is_boolean":true},"TX_NODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Connection point TNI"}},"visibility":"Private","trigger":"Daily","pagination":["Elec64_1.htm"]},"MAS_CP_MASTER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#559"],"comment":"MAS_CP_MASTER shows the current MAS configuration.","description":"Obsolete; Replaced by MSATS\n\nSource\n\nMAS_CP_MASTER updates daily with each MAS export.\n\nNote\n\n| In_Use Value | Meaning |\n|--------------|---------|\n| Y            | ACTIVE  |\n| N            | CLOSED  |\n| X            | EXTINCT |","unused":true,"primary_keys":["NMI","VALID_TO_DATE"],"indexes":[["LASTCHANGED"]],"columns":{"NMI":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"National Metering Identifier"},"VALID_TO_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Record valid to date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AGGREGATE_DATA":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Aggregate data flag (YIN)","is_boolean":true},"AVERAGE_DAILY_LOAD_KWH":{"sql_type":"NUMBER(8,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Average daily load in KWh","is_integer":true,"num_int_bits":32},"CITY_SUBURB":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point city/suburb"},"CP_DETAIL_1":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point detail 1"},"CP_DETAIL_2":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point detail 2"},"CP_NAME":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Connection point name"},"CP_SECURITY_CODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Security Code"},"DISTRIBUTION_LOSS":{"sql_type":"NUMBER(5,4)","pl_type":"pl.Float64","mandatory":false,"comment":"Distribution loss factor","is_float":true},"FINANCIAL_PARTICIPANT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"FRMP"},"FRMP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"FRMP text field"},"IN_USE":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Active/Inactive Status flag (NEW/N/Y/X)","is_boolean":true},"JURISDICTION":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":false},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_NETWORK_PROVIDER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"LNSP"},"LOCAL_RETAILER":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Local Retailer"},"LR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"LR text field"},"LSNP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"LNSP text field (name has misspelt LNSP)"},"MDA_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"MDA text field"},"METERING_DATA_AGENT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"MDA"},"METERING_TYPE":{"sql_type":"VARCHAR2(9)","pl_type":"pl.Categorical","mandatory":false},"NMI_CLASS":{"sql_type":"VARCHAR2(9)","pl_type":"str","mandatory":false},"POST_CODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Connection point postcode"},"RESPONSIBLE_PERSON":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Responsible Person"},"RETAILER_OF_LAST_RESORT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"ROLR"},"ROLR_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"ROLR text field"},"RP_TEXT":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"RP text field"},"STATE":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":false,"comment":"State of Australia"},"TX_NODE":{"sql_type":"VARCHAR2(4)","pl_type":"str","mandatory":false,"comment":"Connection point TNI"},"VALID_FROM_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Record valid from date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Daily"},"MCC_CASESOLUTION":{"package":"MCC_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"MCC","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec71.htm#1"],"comment":"Top level table for each MCC dispatch rerun process. Note there will be one record for each dispatch interval","primary_keys":["RUN_DATETIME"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"5-minute Dispatch Run identifier","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MCC_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":23802,"decompressed_size_all_time":35796120},"visibility":"Private & Public Next-Day","trigger":"Each dispatch run"},"MCC_CONSTRAINTSOLUTION":{"package":"MCC_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"MCC","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec71.htm#7"],"comment":"Constraint solution data from the MCC dispatch rerun process. Note only constraints with a non-zero marginal value are published.","primary_keys":["CONSTRAINTID","RUN_DATETIME"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint identifier (synonymous with GenConID)","examples":["#ERB02_E1","#SSE_PPCCGT_20","F_I+BIP_ML_L1","F_I+GFT_TG_R5","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++LREG_0210","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+LREG_0210","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_T++NIL_CHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_WF_TG_R60","F_T+LREG_0050","F_T+NIL_FCSPS_R60","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6","I_6F_SN_150","SVML_ZERO","S^SNWWF_60","S^WPWF_60","T_BLINK_TV_NGZ","V::N_NIL_O2","VTBL_NIL_CONT_441","V^^N_NIL_1","V_DUNDWF1_2_3_168","V_NWVIC_GFT1_750","V_SH_DD_MAC_FLT_965","V_T_NIL_BL1"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"5-minute Dispatch Run identifier","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Generic Constraint Marginal Value for this MCC run","examples":["-0.38951","0.00028","-1010.50362","23206.62311"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Generic Constraint RHS Value for this MCC run","examples":["-0.01","0.01","-125","441"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MCC_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1832287,"decompressed_size_all_time":1831384810},"visibility":"Private & Public Next-Day","trigger":"Each MCC dispatch rerun"},"METERDATA":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"METER_DATA","REPORT_SUB_TYPE":"CUSTOMER","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#570"],"comment":"METERDATA sets out a meter data for each customer connection point. METERDATA covers market load. Use the field METERRUNNO to match the meter data version for each settlement run.","description":"METERDATA data is confidential to the relevant participant.\n\nSource\n\nMETERDATA updates whenever meter files are processed from MSATS.\n\nVolume\n\nDepends on number of TNI, FRMP, LR combinations and number of data file\nloads (versions) from MSATS per settlement run.","unused":true,"primary_keys":["CONNECTIONPOINTID","HOSTDISTRIBUTOR","MDA","METERRUNNO","PARTICIPANTID","PERIODID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Transmission Node Identifier (TNI). Identifies a Transmission NetworkConnection Point.","is_categorical":true},"HOSTDISTRIBUTOR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Local Retailer participant identifier","name_in_csv":"LOCAL_RETAILER"},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Defaults to MSATS"},"METERRUNNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":true,"comment":"Data version no","is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","name_in_csv":"FRMP","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period identifier (half hour period)","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTENERGYVALUE":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Exported energy value (MWh)","is_float":true},"IMPORTENERGYVALUE":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Imported energy value (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTREACTIVEVALUE":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"IMPORTREACTIVEVALUE":{"sql_type":"NUMBER(9,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private","trigger":"When meter files are processed from MSATS"},"METERDATATRK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"METER_DATA","REPORT_SUB_TYPE":"CUSTOMER_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#595"],"comment":"METERDATATRK records meter data files submitted for each connection point on a daily basis. The same data is provided in METERDATA period by period (i.e. 48 records), whereas METERDATATRK shows one record per day for each file submitted for a connection point.","description":"METERDATATRK data is confidential to the relevant participant.\n\nSource\n\nMETERDATATRK updates whenever meter files are processed.\n\nVolume\n\nDepends on the number of TNI, FRMP and LR combinations plus the number\nof data file loads (versions) from MSATS per settlement run.","unused":true,"primary_keys":["CONNECTIONPOINTID","HOSTDISTRIBUTOR","METERINGDATAAGENT","METERRUNNO","PARTICIPANTID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Transmission Node Identifier (TNI)","is_categorical":true},"HOSTDISTRIBUTOR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Local retailer participant identifier","name_in_csv":"LOCAL_RETAILER"},"METERINGDATAAGENT":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Defaults to MSATS"},"METERRUNNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":true,"comment":"Meter data version number","is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","name_in_csv":"FRMP","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement calendar date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date processed","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Meter file name (MSATS file name)"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACKFILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Not used","unused":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Not used","unused":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to METERDATA_TRK","category":"related_tables"}],"trigger":"Updates whenever meter files are processed"},"METERDATA_AGGREGATE_READS":{"package":"METER_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"AGGREGATE_READS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec37.htm#1"],"comment":"Publishes aggregated metering data associated with a wholesale connection point for a given CASE_ID","primary_keys":["CASE_ID","CONNECTIONPOINTID","FRMP","LR","METER_TYPE","PERIODID","SETTLEMENTDATE"],"indexes":[["CASE_ID","SETTLEMENTDATE","CONNECTIONPOINTID","METER_TYPE","FRMP","LR","PERIODID"]],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Case Identifier","is_integer":true,"num_int_bits":64},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point ID","is_categorical":true},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The financially responsible market participantid"},"LR":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The local retailer at the connection point id"},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The meter type for the read, one of: CUSTOMER; GENERATOR; EMBEDDED_GENERATOR"},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date within the case","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":true,"comment":"The export(pool-centric) value for the meter read (MWh)","is_float":true},"IMPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":true,"comment":"The import(pool-centric) value for the meter read (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"METERDATA_GEN_DUID":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"METER_DATA","REPORT_SUB_TYPE":"GEN_DUID","VERSION":1}],"transaction_type":"INSERT-UPDATE"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#579"],"comment":"Recorded actual generation of non-scheduled units where SCADA data is available.","unused":true,"primary_keys":["DUID","INTERVAL_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Timestamp of the recorded interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp of last record change","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MWH_READING":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"MW reading","is_float":true}},"visibility":"Public","trigger":"When there is generation of non-scheduled units"},"METERDATA_INDIVIDUAL_READS":{"package":"METER_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"INDIVIDUAL_READS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec37.htm#9"],"comment":"Publishes metering data associated with individual metering points for a given CASE_ID","primary_keys":["CASE_ID","METER_ID","METER_ID_SUFFIX","PERIODID","SETTLEMENTDATE"],"indexes":[["CASE_ID","SETTLEMENTDATE","METER_ID","METER_ID_SUFFIX","PERIODID"]],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Case Identifier","is_integer":true,"num_int_bits":64},"METER_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The National Metering Identifier (NMI)"},"METER_ID_SUFFIX":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The National Metering Identifier (NMI) data stream"},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date within the case","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point ID","is_categorical":true},"EXPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":true,"comment":"The export(pool-centric) value for the meter read (MWh)","is_float":true},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The financially responsible market participantid"},"IMPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":true,"comment":"The import(pool-centric) value for the meter read (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LR":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The local retailer at the connection point id"},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The meter type for the read, one of: CUSTOMER; GENERATOR; EMBEDDED_GENERATOR"}},"visibility":"Private"},"METERDATA_INTERCONNECTOR":{"package":"METER_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"INTERCONNECTOR","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec37.htm#17"],"comment":"Publishes metering data associated with wholesale interconnectors for a given CASE_ID","primary_keys":["CASE_ID","INTERCONNECTORID","PERIODID","SETTLEMENTDATE"],"indexes":[["CASE_ID","SETTLEMENTDATE","INTERCONNECTORID","PERIODID"]],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Case Identifier","examples":["11804","11829"],"is_integer":true,"num_int_bits":64},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval.","examples":["1","288"],"is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement date within the case","examples":["2026/02/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"EXPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The export direction value for the meter read (MWh)","examples":["0.0000157","0","104.758031"],"is_float":true},"IMPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The import direction value for the meter read (MWh)","examples":["0.0001707","0","102.3317617"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/09/05 01:02:43"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23METERDATA_INTERCONNECTOR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3464113,"decompressed_size_all_time":593607200},"visibility":"Public"},"METERDATA_SAPS":{"package":"METER_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"METERDATA_SAPS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec37.htm#25"],"comment":"The SAPS Meter data for MSRP and Retailer used in the Settlement Calculation","primary_keys":["CASE_ID","CONNECTIONPOINT_ID","FRMP","LR","METER_TYPE","PERIODID","SETTLEMENTDATE"],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"The Metering Case ID used for Settlements","is_integer":true,"num_int_bits":64},"CONNECTIONPOINT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The SAPS Connection Point Id"},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Financial Responsible Market Participant"},"LR":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Local Retailer"},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Meter Type Identifier , CUSTOMER or MSRP"},"PERIODID":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date for that Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy in MWh","is_float":true},"IMPORTVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Sent Out Energy in MWh","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Date time of the record last updated or inserted.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"METERDATA_TRK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#587"],"comment":"Tracking table for the publication of wholesale settlement data associated with BILLING run","unused":true,"primary_keys":["CASE_ID"],"indexes":[["CASE_ID"]],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Case Identifier","is_integer":true,"num_int_bits":64},"AGGREGATE_READS_LOAD_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp of the aggregated reads being loaded for this case","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The end date of data associated with the Case_ID","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INDIVIDUAL_READS_LOAD_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp of the non aggregated reads being loaded for this case","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The start date of data associated with the CASE_ID","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","warnings":[{"msg":"This is a different table to METERDATATRK","category":"related_tables"}],"trigger":"Posting of a billing run"},"METERDATA_WDR_READS":{"package":"METER_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"METERDATA","REPORT_SUB_TYPE":"WDR_READS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec37.htm#31"],"comment":"Metering Data WDR Readings","primary_keys":["CASE_ID","MARKET_ID","METER_ID","PERIODID","SETTLEMENTDATE"],"columns":{"CASE_ID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Unique identifier for the metering case.","is_integer":true,"num_int_bits":64},"MARKET_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the market to which this metering record applies. Always equal to NEM in the current system."},"METER_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the meter to which the metering record applies"},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier, with Period 1 being the first TI for the calendar day, i.e interval ending 00:05.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The settlement date for the metering record","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BASELINECALCULATIONID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A reference to the baseline run that produced the baseline quantity for this NMI and interval"},"BASELINEQUANTITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Baseline quantity in MWh for the NMI in the trading interval. A negative value indicates net consumption, while a positive value indicates the net generation","is_float":true},"DRSP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier for the participant acting as the DRSP for this NMI on the settlement date"},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier for the participant acting as the FRMP for this NMI on the settlement date"},"ISNONCOMPLIANT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"A value of TRUE (indicated by 1) for this column indicates that financial settlement of WDR transactions for this NMI should not proceed for the settlement date and trading interval. Possible values are 1 and 0.","is_integer":true,"num_int_bits":8},"METEREDQUANTITYEXPORT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Metered quantity Export in MWh for the NMI in the trading interval. A negative value indicates net consumption, while a positive value indicates net generation","is_float":true},"METEREDQUANTITYIMPORT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Metered quantity Import in MWh for the NMI in the trading interval. A negative value indicates net consumption, while a positive value indicates net generation","is_float":true},"QUALITYFLAG":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Boolean","mandatory":false,"comment":"Quality flag for the meter read. Where multiple datastreams exist against the NMI with different quality flags for each read, the lowest quality flag will be published against the NMI for the interval.","is_boolean":true},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier for the transmission node to which this meter belongs on the settlement date"}},"visibility":"Private","trigger":"Posting of a billing run"},"MMS_DATA_MODEL_AUDIT":{"package":"CONFIGURATION","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec4.htm#1"],"comment":"MMS_DATA_MODEL_AUDIT shows the audit trail of scripts applied to this installation of MMS Data Model. Participants should ensure that if a database is cloned the content of this table is copied to the target database.","description":"Source\n\nDelivered within scripts comprising install or updates to the MMS Data\nModel schema.\n\nVolume\n\n1 record is inserted per release of MMS Data Model managed product","primary_keys":["INSTALL_TYPE","INSTALLATION_DATE","MMSDM_VERSION"],"columns":{"INSTALL_TYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of the patch applied. Valid entries are: FULL, UPGRADE, DML"},"INSTALLATION_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date in which the changes to the MMS Data Model were installed","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"MMSDM_VERSION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The version of MMS Data Model after the script has been applied"},"NEM_CHANGE_NOTICE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The NEM Change notice for which this MMS Data Model applies"},"PROJECT_TITLE":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"The name of the business project for which these changes to the MMS Data Model apply"},"SCRIPT_VERSION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The version of the patch set to the MMS Data Model"},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"The status of the upgrade. Valid entries are STARTED, FAILED, SUCCESS"},"USERNAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"The USER applying this script"}},"visibility":"Private","warnings":[{"msg":"This table contains metadata about the overall dataset. You probably do not need to look at this unless you are configuring [PDR Loader](../../guide/downloading.md#pdr-batcher-and-pdr-loader).\n","level":"tip"}],"trigger":"When scripts are used to install or update the MMS Data Model"},"MNSP_BIDOFFERPERIOD":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":1},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":2},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MNSP_BIDOFFERPERIOD","VERSION":1,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#49"],"comment":"MNSP_BIDOFFERPERIOD shows availability for 5-minute periods for a specific Bid and LinkID for the given Trading Date and period. MNSP_BIDOFFERPERIOD is a child to MNSP_DAYOFFER and links to BIDOFFERFILETRK for 5MS Bids.","primary_keys":["LINKID","OFFERDATETIME","PERIODID","TRADINGDATE"],"columns":{"LINKID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS","BLNKVIC"]},"OFFERDATETIME":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","examples":["2026/05/05 15:16:58.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period ID, 1 to 288","examples":["1","288"],"is_integer":true,"num_int_bits":16},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The trading date this bid is for","examples":["2026/07/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"BANDAVAIL1":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 1","examples":["0"],"is_float":true},"BANDAVAIL2":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 2","examples":["0","100"],"is_float":true},"BANDAVAIL3":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 3","examples":["100"],"is_float":true},"BANDAVAIL4":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 4","examples":["100"],"is_float":true},"BANDAVAIL5":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 5","examples":["100"],"is_float":true},"BANDAVAIL6":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 6","examples":["100"],"is_float":true},"BANDAVAIL7":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 7","examples":["78","94"],"is_float":true},"BANDAVAIL8":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 8","examples":["0"],"is_float":true},"BANDAVAIL9":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 9","examples":["0"],"is_float":true},"BANDAVAIL10":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability at price band 10","examples":["0"],"is_float":true},"FIXEDLOAD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output, in MW. A value of NULL means no fixed load so the unit is dispatched according to bid and the market.","is_float":true},"MAXAVAIL":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum planned availability MW","examples":["0"],"is_float":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Allows for future use for Energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["438"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Ramp rate (MW / min) in the positive direction of flow for this MNSP link for this half-hour period","examples":["200"],"is_integer":true,"num_int_bits":32},"RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The advance notice(in hours) that a Scheduled Resource requires to achieve the PASA Availability MW for this trading interval","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MNSP_BIDOFFERPERIOD%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2021,"month":3},"last_month":{"year":2026,"month":7},"compressed_size_per_month":14101,"decompressed_size_all_time":62621908850},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The filenames of zips may not correspond to the tables. These can be mixed up with MNSP_PEROFFER. Check column 2 and 3 inside the CSV against `REPORT_NAME` and `REPORT_SUBTYPE` to be sure. I have already done this for you, and listed all URLs in [this metadata file](../../manifests/per_table/csv/MNSP_BIDOFFERPERIOD.csv).\n","category":"filenames"}],"trigger":"Generated as submissions are processed in next-day reports"},"MNSP_DAYOFFER":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"MNSP_DAYOFFER","VERSION":2},{"REPORT_NAME":"BIDS","REPORT_SUB_TYPE":"MNSP_DAYOFFER","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MNSP_DAYOFFER","VERSION":2,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#55"],"comment":"MNSP_DAYOFFER updates as bids are processed. All bids are available as part of next day market data. MNSP_DAYOFFER is the parent table to MNSP_BIDOFFERPERIOD, and joins to BIDOFFERFILETRK for 5MS Bids.","description":"MNSP_DAYOFFER shows own (confidential) data updates as bids are\nprocessed. All bids are available as part of next day market data.\n\nVolume\n\n4, 000 per year","primary_keys":["LINKID","OFFERDATE","PARTICIPANTID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"LINKID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS","BLNKVIC"]},"OFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"Time this bid was processed and loaded","examples":["2026/05/05 15:16:58.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","examples":["BASSLINK"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market Date from which bid is active","examples":["2026/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data will take precedence","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENTRYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Bid type. Either Rebid or Daily","examples":["DAILY"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/05/05 15:16:58"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Mandatory Restriction Offer Factor","is_float":true},"PRICEBAND1":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 1","examples":["0.01","0"],"is_float":true},"PRICEBAND2":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 2","examples":["25","40"],"is_float":true},"PRICEBAND3":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 3","examples":["55","61"],"is_float":true},"PRICEBAND4":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 4","examples":["75"],"is_float":true},"PRICEBAND5":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 5","examples":["89","95"],"is_float":true},"PRICEBAND6":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 6","examples":["104","135"],"is_float":true},"PRICEBAND7":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 7","examples":["114","200"],"is_float":true},"PRICEBAND8":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 8","examples":["200","1000"],"is_float":true},"PRICEBAND9":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 9","examples":["450","5000"],"is_float":true},"PRICEBAND10":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Price for Availability Band 10","examples":["20299","20300"],"is_float":true},"REBID_AWARE_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. The time at which the participant became aware of the event(s) / occurrence(s) that prompted the rebid. Not validated by AEMO"},"REBID_CATEGORY":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Enum([\"A\", \"P\", \"F\", \"E\", \"Z\", \"I\"])","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. A provided rebid category. Not validated by AEMO","examples":null,"warnings":["AEMO does not enforce compliance with the bidding rules. One in every few million rows has a lowercase value here. You should coerce to uppercast before casting to enum or querying.\n"],"coerce_to_uppercase":true,"enums":["A","P","F","E","Z","I"]},"REBID_DECISION_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Intended to support the Rebidding and Technical Parameters Guideline. The time at which the participant made the decision to rebid. Not validated by AEMO"},"REBID_EVENT_TIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The time of the event(s) or other occurrence(s) cited/adduced as the reason for the rebid. Required for rebids, not required for fixed load or low ramp rates. Expected in the format: HH:MM:SS e.g. 20:11:00","examples":["15:15:00"]},"REBIDEXPLANATION":{"sql_type":"VARCHAR2(500)","pl_type":"str","mandatory":false,"comment":"Explanation for all rebids and inflexibilities","examples":["INITIAL OFFER"]},"REFERENCE_ID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"A participants unique Reference Id","examples":["BASSLINK_EO_20260701_20260505151658284","BASSLINK_EO_20260702_20260505151658365","BASSLINK_EO_20260703_20260505151658345","BASSLINK_EO_20260704_20260505151658332","BASSLINK_EO_20260705_20260505151658322","BASSLINK_EO_20260706_20260505151658306","BASSLINK_EO_20260707_20260505151658299","BASSLINK_EO_20260708_20260505151658291","BASSLINK_EO_20260709_20260505151742359"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MNSP_DAYOFFER%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":7},"has_missing_months":true,"compressed_size_per_month":786,"decompressed_size_all_time":93763130},"visibility":"Private & Public Next-Day","trigger":"Generated as submissions are processed in next-day reports"},"MNSP_FILETRK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"MNSP_FILETRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#604"],"comment":"MNSP_FILETRK shows all MNSPOFFERS transmitted to the MMS system.","description":"MNSP_FILETRK is confidential to the relevant participant.\n\nSource\n\nMNSP_FILETRK updates for every submitted MNSP bid.\n\nVolume\n\n4000 per year, being one per bid containing an MNSP bid","unused":true,"primary_keys":["FILENAME","OFFERDATE","PARTICIPANTID","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":true,"comment":"File name for default bids, bids, rebids, re-offers or meter files, as appropriate to table"},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The actual date and time the bid file was submitted by the participant","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market Date from which bid is active","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ACKFILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Acknowledge file name for bids, rebids"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Load status [SUCCESSFUL/CORRUPT]"}},"visibility":"Private","trigger":"A submitted MNSP bid"},"MNSP_INTERCONNECTOR":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"MNSP_INTERCONNECTOR","VERSION":1},{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"MNSP_INTERCONNECTOR","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#97"],"comment":"MNSP_INTERCONNECTOR sets out attributes of each interconnector.","description":"MNSP_INTERCONNECTOR data is public, so is available to all participants.\n\nSource\n\nMNSP_INTERCONNECTOR changes infrequently, typically annually.\n\nVolume\n\nTwice the number of MNSPs.","primary_keys":["EFFECTIVEDATE","LINKID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date when Interconnector becomes effective","examples":["2000/04/06 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LINKID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS","BLNKVIC","DLNKNSW","DLNKQLD","MLINKSA","MLINKVIC","MLNKSA","MLNKVIC"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data will take precedence","examples":["1","3"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorising officer","examples":["BATCH","LUKEB","RGILLETT","TOM","Tom"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of authorisation. Nominal date but required to enable Interconnector.","examples":["2000/04/06 10:04:46"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FROM_REGION_TLF":{"sql_type":"NUMBER(12,7)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor for Link \"From Region\" end","examples":["0.962","1","0.9907"],"is_float":true},"FROMREGION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Nominated source region for Interconnector","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","T-V-MNSP1","V-S-MNSP1"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2000/04/06 10:04:46"],"parse_csv_as_string":true,"is_s_datetime":true},"LHSFACTOR":{"sql_type":"NUMBER(12,7)","pl_type":"pl.Float64","mandatory":false,"comment":"Factor applied to the LHS of constraint equations; set by AEMO","examples":["-1","1"],"is_float":true},"MAXCAPACITY":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum capacity","examples":["200","600"],"is_integer":true,"num_int_bits":32},"METERFLOWCONSTANT":{"sql_type":"NUMBER(12,7)","pl_type":"pl.Float64","mandatory":false,"comment":"Obsolete; no longer applied. Ignore.","examples":["0"],"is_float":true},"TLF":{"sql_type":"NUMBER(12,7)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor (redundant from May 2012)","examples":["0.9682","1","1.1023"],"is_float":true},"TO_REGION_TLF":{"sql_type":"NUMBER(12,7)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor for Link at \"To Region\" end","examples":["0.962","1","0.9907"],"is_float":true},"TOREGION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Nominated destination region for Interconnector","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MNSP_INTERCONNECTOR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1810,"decompressed_size_all_time":2263650},"visibility":"Public","trigger":"Infrequently, typically annually"},"MNSP_OFFERTRK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"MNSP_OFFERTRK","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MNSP_OFFERTRK","VERSION":1,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#613"],"comment":"MNSP_OFFERTRK records all valid MNSPOFFERS loaded into the MMS system. The authorised date reflects the date and time of the load. MNSP_OFFERTRK is key for tracking MNSP bid submission.","description":"MNSP_OFFERTRK shows own (confidential) data updates as bids are\nprocessed. All bids are available as part of next day market data.\n\nVolume\n\n4000 per year","unused":true,"primary_keys":["FILENAME","OFFERDATE","PARTICIPANTID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":true,"examples":["BASSLINK_OFFER_20210201_001.TXT","BASSLINK_OFFER_20210201_002.TXT","BASSLINK_OFFER_20210201_003.TXT","BASSLINK_OFFER_20210201_004.TXT","BASSLINK_OFFER_20210201_005.TXT","BASSLINK_OFFER_20210201_006.TXT","BASSLINK_OFFER_20210201_007.TXT","BASSLINK_OFFER_20210201_008.TXT","BASSLINK_OFFER_20210201_009.TXT","BASSLINK_OFFER_20210202_001.TXT","BASSLINK_OFFER_20210202_002.TXT","BASSLINK_OFFER_20210202_003.TXT","BASSLINK_OFFER_20210202_004.TXT","BASSLINK_OFFER_20210202_005.TXT","BASSLINK_OFFER_20210202_006.TXT","BASSLINK_OFFER_20210202_007.TXT","BASSLINK_OFFER_20210202_008.TXT","BASSLINK_OFFER_20210202_009.TXT","BASSLINK_OFFER_20210203_001.TXT","BASSLINK_OFFER_20210203_002.TXT","BASSLINK_OFFER_20210203_003.TXT","BASSLINK_OFFER_20210203_004.TXT","BASSLINK_OFFER_20210203_005.TXT","BASSLINK_OFFER_20210203_006.TXT","BASSLINK_OFFER_20210203_007.TXT","BASSLINK_OFFER_20210203_008.TXT","BASSLINK_OFFER_20210203_009.TXT","BASSLINK_OFFER_20210204_001.TXT","BASSLINK_OFFER_20210204_002.TXT","BASSLINK_OFFER_20210204_003.TXT","BASSLINK_OFFER_20210204_004.TXT","BASSLINK_OFFER_20210204_005.TXT","BASSLINK_OFFER_20210204_006.TXT","BASSLINK_OFFER_20210204_007.TXT","BASSLINK_OFFER_20210204_008.TXT","BASSLINK_OFFER_20210204_009.TXT","BASSLINK_OFFER_20210205_001.TXT","BASSLINK_OFFER_20210205_002.TXT","BASSLINK_OFFER_20210205_003.TXT","BASSLINK_OFFER_20210205_004.TXT","BASSLINK_OFFER_20210205_005.TXT","BASSLINK_OFFER_20210205_006.TXT","BASSLINK_OFFER_20210205_007.TXT","BASSLINK_OFFER_20210205_008.TXT","BASSLINK_OFFER_20210205_009.TXT","BASSLINK_OFFER_20210205_010.TXT","BASSLINK_OFFER_20210206_001.TXT","BASSLINK_OFFER_20210206_002.TXT","BASSLINK_OFFER_20210206_003.TXT","BASSLINK_OFFER_20210206_004.TXT","BASSLINK_OFFER_20210206_005.TXT","BASSLINK_OFFER_20210206_006.TXT","BASSLINK_OFFER_20210206_007.TXT","BASSLINK_OFFER_20210206_008.TXT","BASSLINK_OFFER_20210206_009.TXT","BASSLINK_OFFER_20210206_010.TXT","BASSLINK_OFFER_20210206_011.TXT","BASSLINK_OFFER_20210206_012.TXT","BASSLINK_OFFER_20210206_013.TXT","BASSLINK_OFFER_20210206_014.TXT","BASSLINK_OFFER_20210206_015.TXT","BASSLINK_OFFER_20210206_016.TXT","BASSLINK_OFFER_20210206_017.TXT","BASSLINK_OFFER_20210206_018.TXT","BASSLINK_OFFER_20210206_019.TXT","BASSLINK_OFFER_20210206_020.TXT","BASSLINK_OFFER_20210206_021.TXT","BASSLINK_OFFER_20210207_001.TXT","BASSLINK_OFFER_20210207_002.TXT","BASSLINK_OFFER_20210207_003.TXT","BASSLINK_OFFER_20210207_004.TXT","BASSLINK_OFFER_20210207_005.TXT","BASSLINK_OFFER_20210207_006.TXT","BASSLINK_OFFER_20210207_007.TXT","BASSLINK_OFFER_20210207_008.TXT","BASSLINK_OFFER_20210207_009.TXT","BASSLINK_OFFER_20210207_010.TXT","BASSLINK_OFFER_20210208_001.TXT","BASSLINK_OFFER_20210208_002.TXT","BASSLINK_OFFER_20210208_003.TXT","BASSLINK_OFFER_20210208_004.TXT","BASSLINK_OFFER_20210208_005.TXT","BASSLINK_OFFER_20210208_006.TXT","BASSLINK_OFFER_20210208_007.TXT","BASSLINK_OFFER_20210208_008.TXT","BASSLINK_OFFER_20210208_009.TXT","BASSLINK_OFFER_20210208_010.TXT","BASSLINK_OFFER_20210209_001.TXT","BASSLINK_OFFER_20210209_002.TXT","BASSLINK_OFFER_20210209_003.TXT","BASSLINK_OFFER_20210209_004.TXT","BASSLINK_OFFER_20210209_005.TXT","BASSLINK_OFFER_20210209_006.TXT","BASSLINK_OFFER_20210209_007.TXT","BASSLINK_OFFER_20210209_008.TXT","BASSLINK_OFFER_20210209_009.TXT","BASSLINK_OFFER_20210209_010.TXT","BASSLINK_OFFER_20210209_011.TXT","BASSLINK_OFFER_20210209_012.TXT","BASSLINK_OFFER_20210209_013.TXT","BASSLINK_OFFER_20210209_014.TXT","BASSLINK_OFFER_20210209_015.TXT","BASSLINK_OFFER_20210209_016.TXT","BASSLINK_OFFER_20210210_001.TXT","BASSLINK_OFFER_20210210_002.TXT","BASSLINK_OFFER_20210210_003.TXT","BASSLINK_OFFER_20210210_004.TXT","BASSLINK_OFFER_20210210_005.TXT","BASSLINK_OFFER_20210210_006.TXT","BASSLINK_OFFER_20210210_007.TXT","BASSLINK_OFFER_20210210_008.TXT","BASSLINK_OFFER_20210210_009.TXT","BASSLINK_OFFER_20210210_010.TXT","BASSLINK_OFFER_20210211_001.TXT","BASSLINK_OFFER_20210211_002.TXT","BASSLINK_OFFER_20210211_003.TXT","BASSLINK_OFFER_20210211_004.TXT","BASSLINK_OFFER_20210211_005.TXT","BASSLINK_OFFER_20210211_006.TXT","BASSLINK_OFFER_20210211_007.TXT","BASSLINK_OFFER_20210211_008.TXT","BASSLINK_OFFER_20210211_009.TXT","BASSLINK_OFFER_20210211_010.TXT","BASSLINK_OFFER_20210212_001.TXT","BASSLINK_OFFER_20210212_002.TXT","BASSLINK_OFFER_20210212_003.TXT","BASSLINK_OFFER_20210212_004.TXT","BASSLINK_OFFER_20210212_005.TXT","BASSLINK_OFFER_20210212_006.TXT","BASSLINK_OFFER_20210212_007.TXT","BASSLINK_OFFER_20210212_008.TXT","BASSLINK_OFFER_20210212_009.TXT","BASSLINK_OFFER_20210212_010.TXT","BASSLINK_OFFER_20210213_001.TXT","BASSLINK_OFFER_20210213_002.TXT","BASSLINK_OFFER_20210213_003.TXT","BASSLINK_OFFER_20210213_004.TXT","BASSLINK_OFFER_20210213_005.TXT","BASSLINK_OFFER_20210213_006.TXT","BASSLINK_OFFER_20210213_007.TXT","BASSLINK_OFFER_20210213_008.TXT","BASSLINK_OFFER_20210213_009.TXT","BASSLINK_OFFER_20210213_010.TXT","BASSLINK_OFFER_20210214_001.TXT","BASSLINK_OFFER_20210214_002.TXT","BASSLINK_OFFER_20210214_003.TXT","BASSLINK_OFFER_20210214_004.TXT","BASSLINK_OFFER_20210214_005.TXT","BASSLINK_OFFER_20210214_006.TXT","BASSLINK_OFFER_20210214_007.TXT","BASSLINK_OFFER_20210214_008.TXT","BASSLINK_OFFER_20210214_009.TXT","BASSLINK_OFFER_20210215_001.TXT","BASSLINK_OFFER_20210215_002.TXT","BASSLINK_OFFER_20210215_003.TXT","BASSLINK_OFFER_20210215_004.TXT","BASSLINK_OFFER_20210215_005.TXT","BASSLINK_OFFER_20210215_006.TXT","BASSLINK_OFFER_20210215_007.TXT","BASSLINK_OFFER_20210215_008.TXT","BASSLINK_OFFER_20210215_009.TXT","BASSLINK_OFFER_20210216_001.TXT","BASSLINK_OFFER_20210216_002.TXT","BASSLINK_OFFER_20210216_003.TXT","BASSLINK_OFFER_20210216_004.TXT","BASSLINK_OFFER_20210216_005.TXT","BASSLINK_OFFER_20210216_006.TXT","BASSLINK_OFFER_20210216_007.TXT","BASSLINK_OFFER_20210216_008.TXT","BASSLINK_OFFER_20210216_009.TXT","BASSLINK_OFFER_20210217_001.TXT","BASSLINK_OFFER_20210217_002.TXT","BASSLINK_OFFER_20210217_003.TXT","BASSLINK_OFFER_20210217_004.TXT","BASSLINK_OFFER_20210217_005.TXT","BASSLINK_OFFER_20210217_006.TXT","BASSLINK_OFFER_20210217_007.TXT","BASSLINK_OFFER_20210217_008.TXT","BASSLINK_OFFER_20210217_009.TXT","BASSLINK_OFFER_20210218_001.TXT","BASSLINK_OFFER_20210218_002.TXT","BASSLINK_OFFER_20210218_003.TXT","BASSLINK_OFFER_20210218_004.TXT","BASSLINK_OFFER_20210218_005.TXT","BASSLINK_OFFER_20210218_006.TXT","BASSLINK_OFFER_20210218_007.TXT","BASSLINK_OFFER_20210218_008.TXT","BASSLINK_OFFER_20210218_009.TXT","BASSLINK_OFFER_20210219_001.TXT","BASSLINK_OFFER_20210219_002.TXT","BASSLINK_OFFER_20210219_003.TXT","BASSLINK_OFFER_20210219_004.TXT","BASSLINK_OFFER_20210219_005.TXT","BASSLINK_OFFER_20210219_006.TXT","BASSLINK_OFFER_20210219_007.TXT","BASSLINK_OFFER_20210219_008.TXT","BASSLINK_OFFER_20210219_009.TXT","BASSLINK_OFFER_20210220_001.TXT","BASSLINK_OFFER_20210220_002.TXT","BASSLINK_OFFER_20210220_003.TXT","BASSLINK_OFFER_20210220_004.TXT","BASSLINK_OFFER_20210220_005.TXT","BASSLINK_OFFER_20210220_006.TXT","BASSLINK_OFFER_20210220_007.TXT","BASSLINK_OFFER_20210220_008.TXT","BASSLINK_OFFER_20210220_009.TXT","BASSLINK_OFFER_20210221_001.TXT","BASSLINK_OFFER_20210221_002.TXT","BASSLINK_OFFER_20210221_003.TXT","BASSLINK_OFFER_20210221_004.TXT","BASSLINK_OFFER_20210221_005.TXT","BASSLINK_OFFER_20210221_006.TXT","BASSLINK_OFFER_20210221_007.TXT","BASSLINK_OFFER_20210221_008.TXT","BASSLINK_OFFER_20210221_009.TXT","BASSLINK_OFFER_20210222_001.TXT","BASSLINK_OFFER_20210222_002.TXT","BASSLINK_OFFER_20210222_003.TXT","BASSLINK_OFFER_20210222_004.TXT","BASSLINK_OFFER_20210222_005.TXT","BASSLINK_OFFER_20210222_006.TXT","BASSLINK_OFFER_20210222_007.TXT","BASSLINK_OFFER_20210222_008.TXT","BASSLINK_OFFER_20210222_009.TXT","BASSLINK_OFFER_20210223_001.TXT","BASSLINK_OFFER_20210223_002.TXT","BASSLINK_OFFER_20210223_003.TXT","BASSLINK_OFFER_20210223_004.TXT","BASSLINK_OFFER_20210223_005.TXT","BASSLINK_OFFER_20210223_006.TXT","BASSLINK_OFFER_20210223_007.TXT","BASSLINK_OFFER_20210223_008.TXT","BASSLINK_OFFER_20210223_009.TXT","BASSLINK_OFFER_20210224_001.TXT","BASSLINK_OFFER_20210224_002.TXT","BASSLINK_OFFER_20210224_003.TXT","BASSLINK_OFFER_20210224_004.TXT","BASSLINK_OFFER_20210224_005.TXT","BASSLINK_OFFER_20210224_006.TXT","BASSLINK_OFFER_20210224_007.TXT","BASSLINK_OFFER_20210224_008.TXT","BASSLINK_OFFER_20210224_009.TXT","BASSLINK_OFFER_20210225_001.TXT","BASSLINK_OFFER_20210225_002.TXT","BASSLINK_OFFER_20210225_003.TXT","BASSLINK_OFFER_20210225_004.TXT","BASSLINK_OFFER_20210225_005.TXT","BASSLINK_OFFER_20210225_006.TXT","BASSLINK_OFFER_20210225_007.TXT","BASSLINK_OFFER_20210225_008.TXT","BASSLINK_OFFER_20210225_009.TXT","BASSLINK_OFFER_20210226_001.TXT","BASSLINK_OFFER_20210226_002.TXT","BASSLINK_OFFER_20210226_003.TXT","BASSLINK_OFFER_20210226_004.TXT","BASSLINK_OFFER_20210226_005.TXT","BASSLINK_OFFER_20210226_006.TXT","BASSLINK_OFFER_20210226_007.TXT","BASSLINK_OFFER_20210226_008.TXT","BASSLINK_OFFER_20210226_009.TXT","BASSLINK_OFFER_20210227_001.TXT","BASSLINK_OFFER_20210227_002.TXT","BASSLINK_OFFER_20210227_003.TXT","BASSLINK_OFFER_20210227_004.TXT","BASSLINK_OFFER_20210227_005.TXT","BASSLINK_OFFER_20210227_006.TXT","BASSLINK_OFFER_20210227_007.TXT","BASSLINK_OFFER_20210227_008.TXT","BASSLINK_OFFER_20210227_009.TXT","BASSLINK_OFFER_20210228_001.TXT","BASSLINK_OFFER_20210228_002.TXT","BASSLINK_OFFER_20210228_003.TXT","BASSLINK_OFFER_20210228_004.TXT","BASSLINK_OFFER_20210228_005.TXT","BASSLINK_OFFER_20210228_006.TXT","BASSLINK_OFFER_20210228_007.TXT","BASSLINK_OFFER_20210228_008.TXT","BASSLINK_OFFER_20210228_009.TXT"]},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"examples":["2021/01/20 13:01:55"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"examples":["BASSLINK"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"examples":["2021/02/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"examples":["1","21"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"examples":["MARK BOSTE"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2021/01/20 13:01:55"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2021/01/20 13:01:56"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_02/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MNSP_OFFERTRK_202102010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":2},"has_missing_months":true,"compressed_size_per_month":5288,"decompressed_size_all_time":1766480},"visibility":"Private & Public Next-Day","trigger":"As bids are processed"},"MNSP_PARTICIPANT":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"MNSP_PARTICIPANT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#106"],"comment":"MNSP_PARTICIPANT registers MNSP ownership.","description":"MNSP_PARTICIPANT data is public, so is available to all participants.\n\nSource\n\nMNSP_PARTICIPANT updates infrequently, typically annually.\n\nVolume\n\nNumber of MNSPs.","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar date when Interconnector ownership becomes effective","examples":["2000/04/06 00:00:00"],"parse_csv_as_string":true,"is_date":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","T-V-MNSP1","V-S-MNSP1"],"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","examples":["BASSLINK","DIRLINKP","MRYLINK1"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data takes precedence","examples":["1","3"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2000/04/06 10:04:46"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MNSP_PARTICIPANT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":505,"decompressed_size_all_time":668310},"visibility":"Public","trigger":"Infrequently, typically annually"},"MNSP_PEROFFER":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"BID","REPORT_SUB_TYPE":"MNSP_PEROFFER","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MNSP_PEROFFER","VERSION":1,"hard_coded":true}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#622"],"comment":"MNSP_PEROFFER shows period by period availability and other period data pertaining to a specific bid and LinkID for the given Settlement Date.\nMNSP_PEROFFER is a child to MNSP_DAYOFFER and links to MNSP_OFFERTRK.","description":"MNSP_PEROFFER shows own (confidential) data updates as bids are\nprocessed. All bids are available as part of next day market data.\n\nVolume\n\n192, 000 per year","unused":true,"primary_keys":["LINKID","OFFERDATE","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"LINKID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":["BLNKTAS"]},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date for bid","examples":["2021/01/20 13:01:55"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","examples":["BASSLINK"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Trading Interval number","examples":["1","48"],"is_integer":true,"num_int_bits":128},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market Date from which bid is active","examples":["2021/02/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of data for other key data - a higher version for same key data will take precedence","examples":["1","9"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"BANDAVAIL1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["446","594"],"is_integer":true,"num_int_bits":32},"BANDAVAIL5":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL6":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL7":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL8":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL9":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0"],"is_integer":true,"num_int_bits":32},"BANDAVAIL10":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Band Availability for current Period","examples":["0","148"],"is_integer":true,"num_int_bits":32},"FIXEDLOAD":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Boolean","mandatory":false,"comment":"Inflexibility flag and availability. Fixed unit output MW. A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2021/01/20 13:01:56"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXAVAIL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum planned availability MW","examples":["478"],"is_integer":true,"num_int_bits":32},"MR_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Offer amount","is_integer":true,"num_int_bits":32},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Allows for future use for energy bids, being the physical plant capability including any capability potentially available within 24 hours","examples":["478"],"is_integer":true,"num_int_bits":64},"RAMPUPRATE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Ramp rate (MW / min) in the positive direction of flow for this MNSP link for this half-hour period","examples":["200"],"is_integer":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_02/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MNSP_PEROFFER_202102010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":2},"has_missing_months":true,"compressed_size_per_month":77395,"decompressed_size_all_time":23594310},"visibility":"Private & Public Next-Day","warnings":[{"msg":"The filenames of zips may not correspond to the tables. These can be mixed up with MNSP_BIDOFFERPERIOD. Check column 2 and 3 inside the CSV against `REPORT_NAME` and `REPORT_SUBTYPE` to be sure. I have already done this for you, and listed all URLs in [this metadata file](../../manifests/per_table/csv/MNSP_PEROFFER.csv).\n","category":"filenames"}],"trigger":"As bids are processed"},"MR_DAYOFFER_STACK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MR","REPORT_SUB_TYPE":"DAYOFFER_STACK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#631"],"comment":"MR_DAYOFFER_STACK defines the Stack order for each version of the Acceptance Schedule, including all units submitting MR offers for that event. MR_DAYOFFER_STACK is the child to MR_EVENT_SCHEDULE, and parent to MR_PEROFFER_STACK.","description":"Once the offer cut off time has passed and as the schedule changes AEMO\nis obliged to accept MR capacity to meet the schedule in merit order\naccording to the offers submitted. The relationship to a specific\nschedule, the merit order of submitted offers and accepted quantities\nfor each trading interval are stored in the MR_EVENT_SCHEDULE,\nMR_DAYOFFER_STACK and MR_PEROFFER_STACK.\n\nMR_DAYOFFER_STACK sets includes all generators/MNSPs in the region that\nsubmitted an MR offer and a primary key reference to the Offer tables to\nidentify the specific offer used for that unit. MR_DAYOFFER_STACK also\nincludes a Stack Order, irrespective of whether the unit is required to\nmeet the Schedule.\n\nMR_DAYOFFER_STACK updates are confidential on day of submission, with\npublic exposure the next day.\n\nSource\n\nMR_DAYOFFER_STACK updates are ad hoc.\n\nVolume\n\n100 rows per year","unused":true,"primary_keys":["MR_DATE","REGIONID","STACK_POSITION","VERSION_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STACK_POSITION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Loss Adjusted Offer Factor Stack order starting at 1","is_integer":true,"num_int_bits":16},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Allows many Stack versions","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Confirms the unit is allowed to Contribute MR Capacity","is_integer":true,"num_int_bits":8},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID or LinkID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"LAOF":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Loss Adjusted Offer Factor = TLF times MR_Factor","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was last inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFER_OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Foreign key reference to XXXX_DayOffer.OfferDate","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFER_SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Foreign key reference to XXXX_DayOffer.SettlementDate","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Source tables - ENERGY or MNSP"},"OFFER_VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Foreign key reference to XXXX_DayOffer.VersionNo","is_integer":true,"num_int_bits":16}},"visibility":"Private & Public Next-Day","trigger":"Ad hoc"},"MR_EVENT":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MR","REPORT_SUB_TYPE":"EVENT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#640"],"comment":"MR_EVENT defines an MR Event for a given region on a specific trading date.","description":"MR_EVENT defines a mandatory restriction event for a given region and\ntrading date (04:30 to 04:00). Data within MR_EVENT includes the cut-off\ntime for submission of MR offers for this event and a notification that\nthe settlements figures are locked due to results from an independent\nexpert being engaged to allocate settlement of a significant shortfall.\nIf mandatory restrictions are defined in two regions on the same trading\nday, two MR events are defined.\n\nMR_EVENT data is public, so is available to all participants.\n\nSource\n\nMR_EVENT updates are ad hoc.\n\nVolume\n\n1 Row per year","unused":true,"primary_keys":["MR_DATE","REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Ignored - Tracking purpose only"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Required for MR_Event to take effect","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DESCRIPTION":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Description of MR"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFER_CUT_OFF_TIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Cut off after when new Offers and Scaling Factor changes are disallowed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENT_COMPLETE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag:1 = MR settlement figures locked. Do not recalculate, · 0 = MR settlements to be recalculated","is_boolean":true}},"visibility":"Public","trigger":"Ad hoc"},"MR_EVENT_SCHEDULE":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MR","REPORT_SUB_TYPE":"EVENT_SCHEDULE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#649"],"comment":"MR_EVENT_SCHEDULE defines the Stack version of the Acceptance Schedule and is the parent table to MR_DayOffer_Stack and MR_PerOffer_Stack.","description":"Once the offer cut off time has passed and as the schedule changes AEMO\nis obliged to accept MR capacity to meet the schedule in merit order\naccording to the offers submitted. The relationship to a specific\nschedule, the merit order of submitted offers and accepted quantities\nfor each trading interval are stored in the MR_Event_Schedule,\nMR_DayOffer_Stack and MR_PerOffer_Stack table.\n\nThe MR_EVENT_SCHEDULE table determines the existence of an MR offer\nacceptance stack for a specific MR schedule of an MR event. The\nMR_EVENT_SCHEDULE table also tracks the time each stack is exercised.\nMR_EVENT_SCHEDULE is public and notifies the market that a new offer\nstack has been created.\n\nSource\n\nMR_EVENT_SCHEDULE updates are ad hoc.\n\nVolume\n\n2 Rows per year","unused":true,"primary_keys":["MR_DATE","REGIONID","VERSION_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date/Time of Schedule; Allows many Stack versions","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Authorised person confirming Offer Stack (AKA Acceptance)"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the Offer Stack confirmed","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Foreign key reference to ResDemandTrk.EffectiveDate","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Foreign key reference to ResDemandTrk.OfferDate","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Foreign key reference to ResDemandTrk.VersionNo","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Ad hoc"},"MR_PEROFFER_STACK":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MR","REPORT_SUB_TYPE":"PEROFFER_STACK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#658"],"comment":"MR_PEROFFER_STACK defines the accepted capacity on a period basis for the Acceptance Schedule, is a child table to MR_DayOffer_Stack and only includes records or units with accepted_capacity > 0 for the specific period.","description":"Once the offer cut off time has passed and as the schedule changes AEMO\nis obliged to accept MR capacity to meet the schedule in merit order\naccording to the offers submitted. The relationship to a specific\nschedule, the merit order of submitted offers and accepted quantities\nfor each trading interval are stored in MR_Event_Schedule,\nMR_DayOffer_Stack and MR_PerOffer_Stack.\n\nMR_PEROFFER_STACK reports the accepted MR capacity (Accepted_Capacity)\nrequired from each unit for each trading interval. MR_PEROFFER_STACK is\nsparse so lists only units with accepted capacity \\> 0 for that trading\ninterval. The Deducted_Capacity field allows the tracking and\nimplementation of participant requested reductions to accepted MR\ncapacity to be tracked and applied. MR_PEROFFER_STACK is reported\nconfidentially to each participant to notify acceptance of an MR offer.\n\nSource\n\nMR_PEROFFER_STACK updates are ad hoc.\n\nVolume\n\n4800 rows per year","unused":true,"primary_keys":["MR_DATE","PERIODID","REGIONID","STACK_POSITION","VERSION_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"MR_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Mandatory Restriction imposition date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trade Period for the MR Offer","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STACK_POSITION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"LAOF Stack order","is_integer":true,"num_int_bits":16},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Allows many Period Stack versions for the one Scaling Factor stack","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACCEPTED_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MR Capacity to be Dispatched","is_integer":true,"num_int_bits":32},"DEDUCTED_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Requested capacity reduction amount","is_integer":true,"num_int_bits":32},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID or LinkID. Only required here for CSV reports","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was last inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private & Public Next-Day","trigger":"Ad hoc"},"MTPASACONSTRAINTSOLUTION_D":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#719"],"comment":"MTPASACONSTRAINTSOLUTION_D sets out MT PASA constraint solution results, where constraints are binding.","description":"MTPASACONSTRAINTSOLUTION_D is public data.\n\nSource\n\nMTPASACONSTRAINTSOLUTION_D updates weekly.\n\nVolume\n\nEach run overwrites data from previous runs for all future dates. Growth\nis one record per newly effective constraint.","unused":true,"primary_keys":["CONSTRAINT_ID","DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Constraint Identifier"},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date constraint is binding","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEGREE_OF_VIOLATION":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The degree in MW by which the constraint would be violated if the solution could not solve. This could be due to incorrect penalties etc. This figure should always be 0.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed data and time.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The run date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASAINTERCONNECTORSOLUTION_D":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#728"],"comment":"MTPASAINTERCONNECTORSOLUTION_D shows interconnector results for MT PASA, shown region by region.","description":"MTPASAINTERCONNECTORSOLUTION_D is public data.\n\nSource\n\nMTPASAINTERCONNECTORSOLUTION_D updates weekly.\n\nVolume\n\nEach run overwrites data from previous runs for all future dates. Growth\nis one record per day per interconnector.","unused":true,"primary_keys":["DATETIME","INTERCONNECTOR_ID"],"indexes":[["LASTCHANGED"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date of results. One record for each day for next two years.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTOR_ID":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":true,"comment":"Interconnector Identifier"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last change date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEGATIVE_BINDING":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Indication of a binding limit in the in direction"},"NEGATIVE_INTERCONNECTOR_FLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The MW flow in","is_float":true},"NEGATIVE_TRANSFER_LIMITS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"the MW transfer limits in","is_float":true},"POSITIVE_BINDING":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Indication of a binding limit in the out direction"},"POSITIVE_INTERCONNECTOR_FLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The MW flow out","is_float":true},"POSITIVE_TRANSFER_LIMITS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The MW transfer limits out","is_float":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The run date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASAREGIONSOLUTION_D":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#737"],"comment":"MTPASAREGIONSOLUTION_D shows region results for MT PASA, showing predicted demand and any capacity limits.","description":"MTPASAREGIONSOLUTION_D is public data.\n\nSource\n\nMTPASAREGIONSOLUTION_D updates weekly.\n\nVolume\n\nEach run overwrites data from previous runs for all future dates. Growth\nis one record per day per region.","unused":true,"primary_keys":["DATETIME","REGION_ID"],"indexes":[["LASTCHANGED"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date of results. One record for each day for next two years.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGION_ID":{"sql_type":"VARCHAR2(12)","pl_type":"str","mandatory":true,"comment":"Region Identifier"},"CAPACITY_REQUIREMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity in MW required to meet demand","is_float":true},"CONSTRAINED_CAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The total regional capacity due to energy and network constraints","is_float":true},"DEMAND_MINUS_SCHEDULED_LOAD":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional demand minus the scheduled load value","is_float":true},"ENERGY_REQUIREMENT_10POE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional energy required to meet demand","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last change date and time.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MINIMUM_RESERVE_REQUIREMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum required regional reserve value","is_float":true},"NET_INTERCHANGE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional net MW import via interconnectors","is_float":true},"REGION_DEMAND_10POE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional 10% Probability of Exceedance demand forecast value","is_float":true},"REPORTED_BLOCK_ID":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The load duration curve block that is recorded in the report.","is_float":true},"RESERVE_CONDITION":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"The regional reserve condition"},"RESERVE_SURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reserve surplus value","is_float":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The run date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"UNCONSTRAINED_CAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The total regional capacity, subject to network constraints.","is_float":true}},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_CASERESULT":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"CASERESULT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#1"],"comment":"MTPASA solution header table","description":"MTPASA_CASERESULT is public data.\n\nHolds one Record for entire solution","primary_keys":["RUN_DATETIME","RUN_NO"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177","1184"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:28:55"],"parse_csv_as_string":true,"is_s_datetime":true},"PLEXOS_VERSION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Version of PLEXOS used","examples":["8.3"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_CASERESULT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":463,"decompressed_size_all_time":427790},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_CASESOLUTION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":4,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#676"],"comment":"MTPASA_CASESOLUTION is obsolete from 2017 End of Year DM4.27 Release.\nMTPASA_CASESOLUTION holds one record for each entire solution.\nChange Notice 379 announced the replacement of the MT PASA data model so all MTPASAxxx tables become obsolete, replaced by MTPASA_xxx tables.","description":"MTPASA_CASESOLUTION is public data.\n\nSource\n\nMTPASA_CASESOLUTION is updated each MTPASA run (i.e. weekly).\n\nVolume\n\nRows per week: 1\n\nRows per month: 5\n\nMonthly space increment is based on storing all the MT PASA solutions.\nTo store only the latest solution, divide these figures by 5 (number of\nweeks per month rounded up).","unused":true,"primary_keys":["RUN_DATETIME","RUN_NO"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins. Generated from the solution file caseid","examples":["2024/07/01 02:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id. Generated from the solution file caseid","examples":["857","869"],"is_integer":true,"num_int_bits":16},"CAPACITYOBJFUNCTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Objective Function from the Capacity Adequacy run","is_float":true},"CAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for capacity adequacy assessment: 0 = no assessment, 1 = 10%, 2 = 50%, 3 = 90%","is_float":true},"INTERCONNECTORFLOWPENALTY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The penalty for non-zero interconnector flow","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was created or modified","examples":["2024/07/02 12:03:44"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in LOR run (either PASA or MARKET)"},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lack of Reserve Condition (LOR) flag for the case indicates the most severe condition in the case (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)","is_boolean":true,"unsigned_int":true,"num_int_bits":8},"LORDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for LOR assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","is_float":true},"LORUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","is_integer":true,"num_int_bits":16},"MAXSPARECAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum Spare Capacity: 0 = no assessment, 1 = 10%, 2 = 50%, 3 = 90%","is_float":true},"MAXSURPLUSRESERVEOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum surplus Reserve: 0 = no assessment, 1 = 10%, 2 = 50%, 3 = 90%","is_float":true},"OUTAGELRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Outage LRC run (either PASA or MARKET)"},"OUTAGELRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for outage LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","is_float":true},"OUTAGELRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","is_integer":true,"num_int_bits":16},"PASAVERSION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case"},"RELIABILITYLRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Reliability LRC run (either PASA or MARKET)"},"RELIABILITYLRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for Reliability LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","is_float":true},"RELIABILITYLRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","is_integer":true,"num_int_bits":16},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Low Reserve Condition (LRC) flag for the case (1 - LRC in the case, 0 - No LRCs in the case) for capacity run","is_boolean":true},"RUNTYPE":{"sql_type":"VARCHAR2(50)","pl_type":"pl.Categorical","mandatory":false,"comment":"Discontinued in Dec 2005; was description of the constraints included in this run, being either System Normal and Planned Outage Constraints or System Normal Constraints Only"}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MTPASA_CASESOLUTION_202407010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":7},"compressed_size_per_month":581,"decompressed_size_all_time":662870},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_CASE_SET":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#667"],"comment":"MTPASA_CASE_SET is obsolete from 2005 End of Year Release. The RUNTYPE added to the primary key of the detail tables for MTPASA allows for the different types of runs for each case.\nMTPASA_CASE_SET allows a MT PASA scenario to be linked across runs.","description":"Source\n\nUpdate weekly.","unused":true,"primary_keys":["RUN_DATETIME","RUN_NO"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins. Generated from the solution file CASEID.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id. Generated from the solution file CASEID.","is_integer":true,"num_int_bits":16},"CASESETID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Unique id to link a set of cases run from the same inputs","is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the solution was loaded","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPEID":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Unique id for type of run, being either","is_integer":true,"num_int_bits":8}},"visibility":"Public","trigger":"Every MTPASA run (weekly)"},"MTPASA_CONSTRAINTRESULT":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"CONSTRAINTRESULT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#8"],"comment":"Constraint results for Binding or Violating Constraints","description":"MTPASA_CONSTRAINTRESULT is public data.","primary_keys":["CONSTRAINTID","DAY","DEMAND_POE_TYPE","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the constraint. Only binding or violating constraints are reported","examples":["I_6F_NS_150","I_6F_SN_150","N::N_CNCW_2","N::N_SDUT_2","N::Q_AR_VC_LDTW","N::Q_BWMP_LDTW","N::Q_NIL_LDTW","N>94M_9ML1_NIL","N>>DP_TIETX_A","N>>NIL_5_61_N","N>>NIL_61_4","N>>NIL_85_86_S","N>>V_NIL_65_66","N>NIL_998_18","N>NIL_LSDU","N>V_MSSGG_TX","N^^V_BADP_1","N^^V_CNCW_1","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_LIMOSF1_CAP_0","Q:NIL_CS","Q:N_1078","Q>CPWO2_CPWU_CPWO1","Q>GGWO_CPBI_CPWU","Q>GGWO_GGWO_WOTB","Q>LCCP_BCCP_CLWU","Q>NIL_CLWU_LCCP","Q>NIL_CPWU_CLWU","Q>NIL_DRLCLB_NIL","Q>NIL_RGLC_BCCP","Q>NIL_RGLC_CLWU","Q>NIL_WOPW_WOSP","Q>PWSP_PWSP_WOSP","Q^^NIL_TR_CLHA","Q^^TR_CLHA_-050","Q^^TR_CLHA_-350","Q_CS_1850","Q_GLD2_0","Q_OKTA_7247","Q_STR_NIL_KABANWF1","Q_STR_NIL_KEP","Q_STR_NIL_KSP1","Q_STR_NIL_MEWF1","S::V_TBSE_TBSE","S:V_580","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","S>>NIL_RBTU_RBTU","S>>NIL_TWPA_BWMP","S>>NIL_TWPA_TPRS","S>NIL_BWMP_HUWT","S>NIL_BWMP_RHBR-T","S>NIL_HUWT_STBG","S>NIL_NWRB2_NWRB1","S>NIL_SGBN_SGSE-T2","S>SETX_NIL_SETX","S>V_460","S>V_NIL_SETX_SETX1","SA_ISLE_STRENGTH","SVML^NIL_MH-CAP_ON","SVML_FLT_130","S^NIL_SA_NORTH","S_V_NIL_ROCOF","TVBL_NIL_DYN","T_MRWF_GCS","V::N_MLSY_O1","V::N_MLSY_V1","V::N_NIL_O1","V::N_NIL_V1","V::N_SETB_O1","V::N_SETB_V1","V::S_SETB_TBSE_2","V::V_1900","V>>MLSY_GTDPT_MLSY","V>>MLSY_KTDPT_SYML","V>>NIL_ARWB_KGBE","V>>NIL_ARWB_RCWEKG","V>>NIL_BABE_KMRC_1","V>>NIL_EPTT_DDSM_SIP","V>>NIL_MBDD_MBDD","V>>NIL_MLGT_MLGT","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD1_MSDD2_S","V>>NIL_SMTX_SMTX_R5","V>>N_NIL_65_051","V>>N_NIL_65_66","V>>N_NIL_66_65","V>>N_X3_65_66","V>S_460","VS_HEY_600_TEST","VTBL_NIL","V^^MLSY_CRML","V^^N_CNCW_1","V^^N_SDUT_1","V^^V_BDBU_SWVIC","V^^V_NIL_KGTS","V_BGWF_BESS_FLT_100","V_DUNDWF1_ZERO","V_DUNDWF2_ZERO","V_DUNDWF3_ZERO","V_MURRAWRWF_FLT_200","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"],"is_categorical":true},"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this result is for","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value is POE10","examples":["POE10"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"CONSTRAINTVIOLATION10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10th percentile violation degree for this constraint, across iterations and reference years (MW)","examples":["171.09","0","391.93"],"is_float":true},"CONSTRAINTVIOLATION50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50th percentile violation degree for this constraint, across iterations and reference years (MW)","examples":["318.44","0","777.68"],"is_float":true},"CONSTRAINTVIOLATION90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90th percentile violation degree for this constraint, across iterations and reference years (MW)","examples":["471.18","0","1397.91"],"is_float":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The effective date of the constraint used","examples":["2013/07/23 14:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:28:55"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Half hourly period reported, selected as period of maximum NEM scheduled demand (calculated as maximum of scheduled demands, averaged across iterations and reference years)","examples":["37","38"],"is_integer":true,"num_int_bits":16},"PROBABILITYOFBINDING":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Proportion of a constraint binding, across iterations and reference years","examples":["0.16667","0","1","100"],"is_float":true},"PROBABILITYOFVIOLATION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Proportion of a constraint violating, across iterations and reference years","examples":["98.66667","0","100","99.5"],"is_float":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The version of the constraint used","examples":["1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_CONSTRAINTRESULT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":788225,"decompressed_size_all_time":519330250},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_CONSTRAINTSOLUTION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#685"],"comment":"MTPASA_CONSTRAINTSOLUTION is obsolete from 2017 End of Year DM4.27 Release.\nThe MTPASA_CONSTRAINTSOLUTION table holds the binding and violated constraint results from the capacity evaluation, including the RHS value.\nChange Notice 379 announced the replacement of the MT PASA data model so all MTPASAxxx tables become obsolete, replaced by MTPASA_xxx tables.","description":"MTPASA_CONSTRAINTSOLUTION is public data.\n\nSource\n\nMTPASA_CONSTRAINTSOLUTION is updated each MTPASA run (i.e. weekly).\n\nVolume\n\nRows per week: 230\n\nTo store only the latest solution, divide these figures by 5.","unused":true,"primary_keys":["CONSTRAINTID","DAY","ENERGYBLOCK","LDCBLOCK","RUN_DATETIME","RUN_NO","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the constraint","examples":["MT_NSW_HEADROOM","MT_QLD_0","MT_Q^^NIL_CS","MT_Q^^NIL_TR","MT_SA_0","MT_VIC_HEADROOM","N>>N-NIL__H_15M","N>N-NIL_LSDU","N^^V_NIL_1","V>>V_NIL_1A","VSML_220"],"is_categorical":true},"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this solution is for. Generated from the solution file periodid","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGYBLOCK":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Sunday at start of the week for this solutions energy block. Generated from the solution file energy block","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LDCBLOCK":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"LDC block this solution is for. Generated from the solution file periodid","examples":["1"],"is_integer":true,"num_int_bits":16},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins","examples":["2018/05/01 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id. Generated from the solution file caseid","examples":["20"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":["RELIABILITY_LRC"]},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value; 0 if not binding","examples":["0.01","0","3","14491.61"],"is_float":true},"CAPACITYRHS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The RHS value in the capacity evaluation","examples":["-0.05","153.46","0","1705"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree; 0 if not violating","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the solution was loaded","examples":["2018/05/01 12:31:15"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2018/MMSDM_2018_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MTPASA_CONSTRAINTSOLUTION_201805010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2018,"month":5},"compressed_size_per_month":37585,"decompressed_size_all_time":37668960},"visibility":"Public"},"MTPASA_CONSTRAINTSUMMARY":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"CONSTRAINTSUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#15"],"comment":"Constraint Summary results over aggregation periods","description":"MTPASA_CONSTRAINTSUMMARY is public data.","primary_keys":["AGGREGATION_PERIOD","CONSTRAINTID","DAY","DEMAND_POE_TYPE","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"AGGREGATION_PERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Period data is aggregated over. Values are PEAK, SHOULDER, OFFPEAK. PEAK = 14:00-19:59, SHOULDER = 07:00-13:59 and 20:00-21:59, OFFPEAK = 22:00-06:59","examples":["OFFPEAK","PEAK","SHOULDER"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the constraint. Only binding or violating constraints are reported","examples":["I_6F_NS_150","I_6F_SN_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N::Q_NIL_LDTW","N::V_BUDP_MSDD","N::V_CNCW_MSDD","N>94T_945_94K","N>94T_947_72","N>>NIL_060_051","N>>NIL_33_34","N>>NIL_39","N>>NIL_61_4","N>>NIL_85_86_S","N>>NIL_964_84_S","N>>V_NIL_65_66","N>N-NIL_JUTX_LV","N>NIL_75_WOTX_72","N>NIL_901","N>NIL_945_947","N>NIL_94B","N>NIL_94K_1","N>NIL_94T","N>NIL_94T_72","N>NIL_966/1","N>NIL_969","N>NIL_998_18","N>NIL_999_9GL","N>NIL_9GL","N>NIL_9GM","N>NIL_9ML","N>NIL_9R6_991","N>NIL_9R6_9R5","N>NIL_MLTX_LV","N>NIL_YSTX_LV","N^^N_NIL_WGLT","N^^N_NIL_X5_BEKG","N^^V_BADP_1","N^^V_CNCW_1","N_COLEASF1_FLT_50","N_DARLSF_FLT_100","N_FINLYSF1_ZERO","N_LIMOSF1_CAP_0","Q:N_1078","Q>NIL_BCCP_LCCP","Q>NIL_CLWU_LCCP","Q>NIL_CPWU_CLWU","Q>NIL_DRLCLB_NIL","Q>NIL_LCCP_BCCP","Q>NIL_LCCP_CLWU","Q>NIL_RGLC_BCCP","Q>NIL_RGLC_CLWU","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","Q^^TR_CLHA_-350","Q_STR_NIL_CLRSF1","Q_STR_NIL_CSPVPS1","Q_STR_NIL_DAYDSF1","Q_STR_NIL_HAMISF1","Q_STR_NIL_HAYMSF1","Q_STR_NIL_KABANWF1","Q_STR_NIL_KEP","Q_STR_NIL_KSP1","Q_STR_NIL_MEWF1","Q_STR_NIL_RRSF1","Q_STR_NIL_RUGBYR1","Q_STR_NIL_SMCSF1","Q_STR_NIL_WHITSF1","RHSWeek_AGLHAL","RHSWeek_BALB1","RHSWeek_BARKIPS1","RHSWeek_BARRON-1","RHSWeek_BARRON-2","RHSWeek_BHB1","RHSWeek_BLOWERNG","RHSWeek_BLYTHB1","RHSWeek_BRNDBES1","RHSWeek_BULBES1","RHSWeek_CAPBES1","RHSWeek_CG1","RHSWeek_CG2","RHSWeek_CG3","RHSWeek_CG4","RHSWeek_DALNTH1","RHSWeek_DARTM1","RHSWeek_DPNTB1","RHSWeek_DRYCGT3","RHSWeek_EILDON1","RHSWeek_EILDON2","RHSWeek_ERB01","RHSWeek_GANNB1","RHSWeek_GSTONE4","RHSWeek_GUTHEGA","RHSWeek_HBESS1","RHSWeek_HEZ1","RHSWeek_HPR1","RHSWeek_JLA01","RHSWeek_JLA02","RHSWeek_JLA03","RHSWeek_JLA04","RHSWeek_JLB02","RHSWeek_JLB03","RHSWeek_KAREEYA3","RHSWeek_KAREEYA4","RHSWeek_KESSB1","RHSWeek_LDBESS1","RHSWeek_MCKAY1","RHSWeek_MLB01","RHSWeek_MP1","RHSWeek_MURRAY","RHSWeek_NPS","RHSWeek_OAKEY1","RHSWeek_OAKEY2","RHSWeek_ORABESS1","RHSWeek_QPS5","RHSWeek_QPSFB2","RHSWeek_RANGEB1","RHSWeek_RESS1","RHSWeek_RIVNB2","RHSWeek_SHGEN","RHSWeek_SNB01","RHSWeek_SNB02","RHSWeek_TALWA1","RHSWeek_TALWB1","RHSWeek_TB2B1","RHSWeek_TEMPB1","RHSWeek_TIB1","RHSWeek_TRGBESS1","RHSWeek_TUMUT3","RHSWeek_ULPBESS1","RHSWeek_UPPTUMUT","RHSWeek_URANQ11","RHSWeek_URANQ12","RHSWeek_URANQ13","RHSWeek_URANQ14","RHSWeek_VBB1","RHSWeek_WANDB1","RHSWeek_WDBESS1","RHSWeek_WDBESS2","RHSWeek_YWPS2","RHSWeek_YWPS3","RHSWeek_YWPS4","S::V_TBSE_TBSE","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_WEWT","S>>NIL_TWPA_BWMP","S>>NIL_TWPA_TPRS","S>DVTX_NIL_DVTX","S>NIL_BWMP_HUWT","S>NIL_BWMP_RHBR-T","S>NIL_HUWT_STBG","S>NIL_NWRB2_NWRB1","S>NIL_SGBN_SGSE-T2","S>V_NIL_SETX_SETX1","SA_ISLE_STRENGTH","SVML^NIL_MH-CAP_ON","SVML_FLT_130","S^NIL_SA_NORTH","S_V_NIL_ROCOF","TVBL_NIL_DYN","T_MRWF_GCS","UPPERLIMIT_DUNDWF1","UPPERLIMIT_DUNDWF2","UPPERLIMIT_DUNDWF3","UPPERLIMIT_FLYCRKWF","UPPERLIMIT_GANGARR1","UPPERLIMIT_GPWFWST2","UPPERLIMIT_HDWF1","UPPERLIMIT_KIAMSF1","UPPERLIMIT_STWF1","V::N_NIL_O1","V::N_NIL_V1","V::N_SETB_O1","V::N_SETB_V1","V::S_NIL_TBSE_1","V::S_SETB_TBSE_2","V:S_750_HY_TEST","V:T_NIL_BL_1","V>>NIL_ARWB_KGBE","V>>NIL_ARWB_RCWEKG","V>>NIL_ELML_BAML2","V>>NIL_EPTT_DDSM_SIP","V>>NIL_MBDD_MBDD","V>>NIL_MLGT_MLGT","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD1_MSDD2_S","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>N_NIL_65_051","V>>N_NIL_65_66","V>>N_NIL_66_65","V>>X3_WBBA_KGBE","V>NIL_WBBA_KMRC","VS_HEY_600_TEST","VTBL_NIL","V^^N_BADP_1","V^^N_CNCW_1","V^^V_NIL_KGTS","V_BANNERTSF_FLT_45","V_BGWF_BESS_FLT_100","V_CRWARP_FLT_75","V_GANWRSF_FLT_30","V_GANWR_SF_BAT_50","V_KARADSF_FLT_25","V_KIAMSF_FLT_100","V_MURRAWRWF_FLT_200","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF","V_WEMENSF_FLT_45","V_YATPSF_FLT_25"],"is_categorical":true},"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this result is for","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value is POE10","examples":["POE10"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"CONSTRAINTHOURSBINDING":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint hours binding or violating for period, averaged across iterations and reference years","examples":["0.5","0","1","9"],"is_float":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The effective date of the constraint used","examples":["2026/08/13 14:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:28:56"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The version of the constraintID","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_CONSTRAINTSUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":8994018,"decompressed_size_all_time":4760865830},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_DUIDAVAILABILITY":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"DUIDAVAILABILITY","VERSION":2},{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"DUIDAVAILABILITY","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#22"],"comment":"Offered PASA Availability of the scheduled generator DUID for each day over the Medium Term PASA period. The data in this table is input data to the MT PASA process it is not part of the MTPASA solution. The availability does not reflect any energy limitations in the MT PASA offers","primary_keys":["DAY","DUID","PUBLISH_DATETIME","REGIONID"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date on which the PASA availability of DUID applies.","examples":["2026/09/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM DUID.","examples":["ADPBA1","AGLHAL","AGLSOM","ANGAST1","BALB1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BHB1","BLOWERNG","BLYTHB1","BOLIVPS1","BOWWBA1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRNDBES1","BULBES1","BUNGAMB1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CPP_3","CPP_4","CPSA","DALNTH1","DARTM1","DDPS1","DEVILS_G","DPNTB1","DRYCGT1","DRYCGT2","DRYCGT3","EILDON1","EILDON2","ER01","ER02","ER03","ER04","ERB01","ERB02","FISHER","GANNB1","GORDON","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GUTHEGA","HBESS1","HEZ1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","JBUTTERS","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KESSB1","KIDSPHG1","KIDSPHG2","KPP_1","LADBROK1","LADBROK2","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LIMBESS1","LI_WY_CA","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACKNTSH","MANNUMB1","MCKAY1","MEADOWBK","MINTARO","MLB01","MORTLK11","MORTLK12","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MSTUART1","MSTUART2","MSTUART3","MURRAY","NESBESS1","NESBESS2","NPS","OAKEY1","OAKEY2","ORABESS1","OSB-AG","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB2","RANGEB1","REECE1","REECE2","RESS1","RIVNB2","ROMA_7","ROMA_8","SHGEN","SITHE01","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNUG1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","W/HOE#1","W/HOE#2","WALGRV1","WANDB1","WDBESS1","WDBESS2","WILLBES1","WKIEWA1","WOOLES1","WTAHB1","YABULU","YABULU2","YARWUN_1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PUBLISH_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time the report was published.","examples":["2026/09/01 09:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"NEM Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"CARRYOVERSTATUS":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Status of a reported capacity value (e.g. 1 for Yes, 0 for No)","examples":["0","1"],"is_integer":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 09:17:01"],"parse_csv_as_string":true,"is_s_datetime":true},"LATEST_OFFER_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the latest offer used for DUID for this date.","examples":["2023/10/05 16:39:34"],"parse_csv_as_string":true,"is_s_datetime":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Offered PASA Availability of Scheduled generator DUID for the day.","examples":["0","2","1500"],"is_integer":true,"num_int_bits":64},"PASARECALLTIME":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time value","examples":["1","912"],"is_integer":true,"num_int_bits":16},"PASAUNITSTATE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value","examples":["DERATINGPLANBASIC","DERATINGPLANEXTEND","DERATINGUNPLANFORCED","DERATINGUNPLANMAINT","MOTHBALLED","NODERATINGS","OUTAGEPLANBASIC","OUTAGEPLANEXTEND","OUTAGEUNPLANFORCED"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_DUIDAVAILABILITY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":336789410,"decompressed_size_all_time":51782626060},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_INTERCONNECTORRESULT":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"INTERCONNECTORRESULT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#28"],"comment":"Interconnector results for interval of max demand per day","description":"MTPASA_INTERCONNECTORRESULT is public data.","primary_keys":["DAY","DEMAND_POE_TYPE","INTERCONNECTORID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this result is for","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value is POE10","examples":["POE10"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the interconnector","examples":["N-Q-MNSP1","NSW1-QLD1","NSW1-SA1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit, averaged across iterations and reference years","examples":["-0.19","1.51","0","710"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit, averaged across iterations and reference years","examples":["-40.97","0","-150","-928"],"is_float":true},"FLOW10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10th percentile for flows, across iterations and reference years. Positive values indicate exporting, negative values indicate importing (MW)","examples":["-1.93","7.55","0","-1078"],"is_float":true},"FLOW50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50th percentile for flows, across iterations and reference years. Positive values indicate exporting, negative values indicate importing (MW)","examples":["-0.09","1.66","0","350"],"is_float":true},"FLOW90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90th percentile for flows, across iterations and reference years. Positive values indicate exporting, negative values indicate importing (MW)","examples":["-6.39","5.49","0","833"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:29:02"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Half hourly period reported, selected as period of maximum NEM scheduled demand (calculated as maximum of scheduled demands, averaged across iterations and reference years)","examples":["37","40"],"is_integer":true,"num_int_bits":16},"PROBABILITYOFBINDINGEXPORT":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Proportion of iterations and reference years with interconnector constrained when exporting","examples":["0.16667","0","1","100"],"is_float":true},"PROBABILITYOFBINDINGIMPORT":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Proportion of iterations and reference years with interconnector constrained when importing","examples":["0.16667","0","1","100"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_INTERCONNECTORRESULT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":393842,"decompressed_size_all_time":413230710},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_INTERCONNECTORSOLUTION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"INTERCONNECTORSOLUTION","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#694"],"comment":"MTPASA_INTERCONNECTORSOLUTION is obsolete from 2017 End of Year DM4.27 Release.\nThe MTPASA_INTERCONNECTORSOLUTION table shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the ldcblock within the day.\nChange Notice 379 announced the replacement of the MT PASA data model so all MTPASAxxx tables become obsolete, replaced by MTPASA_xxx tables (see Change Notices 400, 400a and 400b).","description":"MTPASA_INTERCONNECTORSOLUTION is public so is available to all\nparticipants.\n\nSource\n\nMTPASA_INTERCONNECTORSOLUTION is updated each MTPASA run (i.e. weekly).\n\nVolume\n\nRows per week: 35280\n\nTo store only the latest solution, divide these figures by 5 (number of\nweeks per month rounded up).","unused":true,"primary_keys":["DAY","ENERGYBLOCK","INTERCONNECTORID","LDCBLOCK","RUN_DATETIME","RUN_NO","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this solution is for. Generated from the solution file periodid","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGYBLOCK":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Sunday at start of the week for this solutions energy block. Generated from the solution file energy block","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for the interconnector","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"LDCBLOCK":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"LDC block this solution is for. Generated from the solution file periodid","examples":["1"],"is_integer":true,"num_int_bits":16},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins","examples":["2018/05/01 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id. Generated from the solution file caseid","examples":["20"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":["OUTAGE_LIMITS"]},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-0.05","0.21","0","650"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow","examples":["-2.19","32.7","0","220"],"is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value; 0 if not binding","examples":["226.28","0","14294.27"],"is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints","is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree, 0 if not violating; where CapacityMWFLow <= export + violation Degree (Deficit)CapacityMWFLow >= import + CapacityViolationDegree (Deficit)","examples":["0"],"is_float":true},"EXPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Export Limit","examples":["MT_Q^^NIL_TR","N>>N-NIL__E_15M","N>>N-NIL__H_15M","N>N-NIL_LSDU","N^^Q_NIL_B4","N^^Q_WIV_N-2","V:SS_BLKRG_790","V:SV_820_MT","V:SV_870_MT","V:S_BLKRG_570","V>>V_NIL_2A_R","V>SMLARHO2","V>S_600_MT","V>S_650_MT","VSML_220","VS_050","V^^S_KHKN_SETB","V^^S_PWSE_SETB"]},"IMPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Import Limit","examples":["MT_F_Q-N_ARTW","MT_Q^^NIL_CS","N::V_DDSM_MSDD","N>N-NIL_DC","N^^V_NIL_1","N_MBTE1_B","N_NIL_TE_B","N_V_HV1075","Q:N_1078","Q:N_NIL_OSC","S:VS_650_MT","S>V_500_MT","S>V_NIL_NIL_RBNW","SV_250_DYN","V::V_1900","V>>V_NIL_1A"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the solution was loaded","examples":["2018/05/01 12:31:15"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2018/MMSDM_2018_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MTPASA_INTERCONNECTORSOLUTION_201805010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2018,"month":5},"compressed_size_per_month":288415,"decompressed_size_all_time":263413440},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_INTERMITTENT_AVAIL":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"MTPASA_INTERMITTENT_AVAIL","VERSION":1},{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"MTPASA_INTERMITTENT_AVAIL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#109"],"comment":"A submission of expected plant availability for intermittent generators for use in MTPASA intermittent generation forecasts","primary_keys":["CLUSTERID","DUID","OFFERDATETIME","TRADINGDATE"],"columns":{"CLUSTERID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Cluster Identifier for this cluster within the DUID"},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time when this cluster availability submission was loaded","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Day for which this cluster availability submission applies","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ELEMENTS_AVAILABLE":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Number of elements within this CLUSTERID (turbines for wind, or inverters for solar) that are available for this TRADINGDATE. Value between 0 and the registered Number of Cluster Elements. Value = 0 means no elements available","is_integer":true,"num_int_bits":32},"ELEMENTS_UNAVAILABLE":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Number of elements within this CLUSTERID (turbines for wind, or inverters for solar) that are not available for this TRADINGDATE. Value between 0 and the registered Number of Cluster Elements.Value = 0 means no elements unavailable","is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On participant data submission"},"MTPASA_INTERMITTENT_LIMIT":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"MTPASA_INTERMITTENT_LIMIT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#115"],"comment":"A submission of expected maximum availability for intermittent generators for use in MTPASA intermittent generation\nforecasts","primary_keys":["DUID","OFFERDATETIME","TRADINGDATE"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Identifier of Dispatchable Unit","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date time file processed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Trading Day for which this unit availability submission applies","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDBYPARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Participant entering the unit availability submission"},"AUTHORISEDBYUSER":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"User entering the unit availability submission"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"UPPERMWLIMIT":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":false,"comment":"Maximum imposed MW limit. Value between 0 and the registered DUID Maximum Capacity.Value = -1 means no limit applies.","is_integer":true,"num_int_bits":32}},"visibility":"Private","trigger":"On participant data submission"},"MTPASA_LOLPRESULT":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"LOLPRESULT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#35"],"comment":"Results for Loss of Load Probability (LOLP) run per day","description":"MTPASA_LOLPRESULT is public data.","primary_keys":["DAY","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this result is for","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always LOLP","examples":["LOLP"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:29:02"],"parse_csv_as_string":true,"is_s_datetime":true},"LOSSOFLOADMAGNITUDE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Loss of Load Magnitude for the worst interval in this region. Values are LOW, MEDIUM, HIGH","examples":["High","Low","Medium"]},"LOSSOFLOADPROBABILITY":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Loss of Load Probability for the worst interval in this region","examples":["0.2","0","1","45"],"is_float":true},"WORST_INTERVAL_DEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The Abstract Operational Demand for the worst interval in this region (MW)","examples":["1053.72","1344","14507.24","11324"],"is_float":true},"WORST_INTERVAL_DSP":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The half hourly aggregate demand side participation for the worst interval period in this region (MW)","examples":["0.01","0","1","157.85"],"is_float":true},"WORST_INTERVAL_INTGEN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The half hourly aggregate intermittent generation for the worst interval in this region (MW)","examples":["2.94","48","5235.37","3906"],"is_float":true},"WORST_INTERVAL_PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"The half hourly interval period with the highest LOLP, or highest region demand if LOLP = 0 for all intervals (1..48)","examples":["1","48"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_LOLPRESULT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":181938,"decompressed_size_all_time":187767180},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually weekly)"},"MTPASA_OFFERDATA":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MTPASA_OFFERDATA","VERSION":1},{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MTPASA_OFFERDATA","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#64"],"comment":"Participant submitted Offers for MTPASA process","primary_keys":["EFFECTIVEDATE","OFFERDATETIME","PARTICIPANTID","UNITID"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"trade date when the offer becomes effective","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date time file processed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"either duid or mnsp linkid","is_categorical":true},"CAPACITY1":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 1 (sunday)","is_integer":true,"num_int_bits":32},"CAPACITY2":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 2 (monday)","is_integer":true,"num_int_bits":32},"CAPACITY3":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 3 (tuesday)","is_integer":true,"num_int_bits":32},"CAPACITY4":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 4 (wednesday)","is_integer":true,"num_int_bits":32},"CAPACITY5":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 5 (thursday)","is_integer":true,"num_int_bits":32},"CAPACITY6":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 6 (friday)","is_integer":true,"num_int_bits":32},"CAPACITY7":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"capacity value day 7 (saturday)","is_integer":true,"num_int_bits":32},"ENERGY":{"sql_type":"NUMBER(9)","pl_type":"pl.Int32","mandatory":false,"comment":"weekly energy constraint value","is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"timestamp when record last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RECALLTIME1":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 1 Sunday","is_integer":true,"num_int_bits":16},"RECALLTIME2":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 2 Monday","is_integer":true,"num_int_bits":16},"RECALLTIME3":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 3 Tuesday","is_integer":true,"num_int_bits":16},"RECALLTIME4":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 4 Wednesday","is_integer":true,"num_int_bits":16},"RECALLTIME5":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 5 Thursday","is_integer":true,"num_int_bits":16},"RECALLTIME6":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 6 Friday","is_integer":true,"num_int_bits":16},"RECALLTIME7":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The recall time associated with the unit state for day 7 Saturday","is_integer":true,"num_int_bits":16},"UNITSTATE1":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 1 Sunday"},"UNITSTATE2":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 2 Monday"},"UNITSTATE3":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 3 Tuesday"},"UNITSTATE4":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for 4 Wednesday"},"UNITSTATE5":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 5 Thursday"},"UNITSTATE6":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 6 Friday"},"UNITSTATE7":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The unit state value for day 7 Saturday"}},"visibility":"Private","trigger":"When a participant MTPASA bid is processed"},"MTPASA_OFFERFILETRK":{"package":"BIDS","pdr_config":{"mappings":[{"REPORT_NAME":"OFFER","REPORT_SUB_TYPE":"MTPASA_OFFERFILETRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.htm#72"],"comment":"Participant submitted Offers for MTPASA process","description":"MTPASA_OFFERFILETRK is confidential to the relevant participant.\n\nSource\n\nMTPASA_OFFERFILETRK updates for every submitted MTPASA bid.\n\nVolume\n\n4000 per year, being one per bid containing an MTPASA bid","primary_keys":["OFFERDATETIME","PARTICIPANTID"],"columns":{"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date time file processed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"FILENAME":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Submitted file name"}},"visibility":"Private","trigger":"When a participant MTPASA bid is processed"},"MTPASA_REGIONAVAILABILITY":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONAVAILABILITY","VERSION":3},{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONAVAILABILITY","VERSION":4}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#48"],"comment":"Stores the Region-aggregate offered PASA Availability of scheduled generators for each day over the Medium Term PASA period. The data in this table is an aggregate of input data to the MT PASA process it is not part of the MTPASA solution. The aggregate availability does not reflect any energy limitations in the MT PASA offers.","description":"MTPASA_REGIONAVAILABILITY is public data.","primary_keys":["DAY","PUBLISH_DATETIME","REGIONID"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date on which the aggregation applies.","examples":["2026/09/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PUBLISH_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time the report was published.","examples":["2026/09/01 09:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"NEM Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"CARRYOVERCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Split of the CARRYOVER component of aggregate capacity vs the currently reported capacity.","examples":["0","19","100"],"is_integer":true,"num_int_bits":64},"DEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"10% probability demand (ex non-scheduled demand)","examples":["1158.38","1778","14882.63","11441"],"is_float":true},"DEMAND10MAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum of the Operational Load as Generated (OPGEN) peaks that occur in all ref years for the P10 traces (MW).","examples":["1196.38","1205","14061.73","11790"],"is_float":true},"DEMAND10MIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum of the Operational Load as Generated (OPGEN) peaks that occur in all ref years for the P10 traces (MW).","examples":["945.79","1008","8641.94","8214"],"is_float":true},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% probability demand (ex non-scheduled demand)","examples":["1127.61","1973","14037.54","10856"],"is_float":true},"DEMAND50MAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum of the Operational Load as Generated (OPGEN) peaks that occur in all ref years for the P50 traces (MW).","examples":["1196.31","1289","13196.9","9486"],"is_float":true},"DEMAND50MIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum of the Operational Load as Generated (OPGEN) peaks that occur in all ref years for the P50 traces (MW).","examples":["945.46","1023","8654.28","8292"],"is_float":true},"ENERGYCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Region energy constrained MW capacity","examples":["0","1601","10600"],"is_integer":true,"num_int_bits":64},"ENERGYREQDEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Total weekly operational as generated consumption (POE 10)","examples":["170.43","0","190","1325.71"],"is_float":true},"ENERGYREQDEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Total weekly operational as generated consumption (POE 50)","examples":["169.34","0","1322.66"],"is_float":true},"ENERGYUNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Region energy unconstrained MW capacity","examples":["828","10297"],"is_integer":true,"num_int_bits":64},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 10:04:59"],"parse_csv_as_string":true,"is_s_datetime":true},"LATEST_OFFER_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the latest offer used in the aggregation for this region and date.","examples":["2026/09/01 07:41:18"],"parse_csv_as_string":true,"is_s_datetime":true},"NONSCHEDULEDGENERATION":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW)","examples":["93","562"],"is_float":true},"PASAAVAILABILITY_SCHEDULED":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Aggregate of the offered PASA Availability for all Scheduled generators in this region.","examples":["1705","16305"],"is_integer":true,"num_int_bits":64}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONAVAILABILITY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17621710,"decompressed_size_all_time":4606700150},"visibility":"Public","trigger":"After each MT PASA run (every 3 hours during market business hours)"},"MTPASA_REGIONAVAIL_TRK":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONAVAILTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#42"],"comment":"The tracking table to assist in versioning of the region-aggregate offered PASA Availability data published to the MTPASA_REGIONAVAILABILITY table.","primary_keys":["PUBLISH_DATETIME"],"columns":{"PUBLISH_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time the report was published.","examples":["2026/09/01 09:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Last date of the report inclusive.","examples":["2029/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LATEST_OFFER_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time of the latest offer used in the report.","examples":["2026/09/01 08:50:34"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"First date of the report inclusive.","examples":["2026/09/06 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONAVAIL_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1503,"decompressed_size_all_time":391430},"visibility":"Public","trigger":"After each MT PASA run (every 3 hours during market business hours)"},"MTPASA_REGIONITERATION":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONITERATION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#55"],"comment":"Region results for Unserved Energy (USE)","description":"MTPASA_REGIONITERATION is public data.","primary_keys":["AGGREGATION_PERIOD","DEMAND_POE_TYPE","PERIOD_ENDING","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE","USE_ITERATION_ID"],"columns":{"AGGREGATION_PERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Period data is aggregated over. Values are YEAR","examples":["YEAR"]},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value is POE10 or POE50","examples":["POE10","POE50"]},"PERIOD_ENDING":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime of day at end of period (i.e. last day of year reported)","examples":["2027/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177","1184"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"USE_ITERATION_ID":{"sql_type":"NUMBER(5)","pl_type":"pl.Int32","mandatory":true,"comment":"Iteration ID, only produced for iterations showing unserved energy>0","examples":["1","153"],"is_integer":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/06 22:08:54"],"parse_csv_as_string":true,"is_s_datetime":true},"USE_ITERATION_EVENT_AVERAGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average unserved energy event size for iteration over year (MW)","examples":["1.7","32","1999.43","1688"],"is_float":true},"USE_ITERATION_EVENT_NUMBER":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Number of half hours showing unserved energy over year, for iteration","examples":["1","185"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONITERATION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":7754,"decompressed_size_all_time":102797870},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_REGIONRESULT":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONRESULT","VERSION":1},{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONRESULT","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#62"],"comment":"Region results for interval of max demand per day.","description":"MTPASA_REGIONRESULT is public data.","primary_keys":["DAY","DEMAND_POE_TYPE","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this result is for","examples":["2026/09/13 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value is POE10","examples":["POE10"]},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"AGGREGATEINSTALLEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The total installed capacity of all generation (MW)","examples":["3362","25976"],"is_float":true},"DEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand value from selected half hourly interval (MW)","examples":["1138.75","1165","10997.68","10218"],"is_float":true},"DEMANDSIDEPARTICIPATION10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10th percentile for demand side participation, across iterations and reference years (MW)","examples":["0"],"is_float":true},"DEMANDSIDEPARTICIPATION50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50th percentile for demand side participation, across iterations and reference years (MW)","examples":["0"],"is_float":true},"DEMANDSIDEPARTICIPATION90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90th percentile for demand side participation, across iterations and reference years (MW)","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:29:02"],"parse_csv_as_string":true,"is_s_datetime":true},"NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Total number of iterations and reference years performed","examples":["600"],"is_float":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Half hourly period reported, selected as period of maximum NEM scheduled demand (calculated as maximum of scheduled demands, averaged across iterations and reference years)","examples":["37","40"],"is_integer":true,"num_int_bits":16},"TOTALAVAILABLEGEN10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10% percentile for available capacity, across iterations and reference years (MW).","examples":["1435.48","1517","11870.6","10914"],"is_float":true},"TOTALAVAILABLEGEN50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50% percentile for available capacity, across iterations and reference years (MW).","examples":["1589.48","1594","12669.23","12308"],"is_float":true},"TOTALAVAILABLEGEN90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90% percentile for available capacity, across iterations and reference years (MW).","examples":["1686.98","1730","13289.03","12009"],"is_float":true},"TOTALAVAILABLEGENMAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum available capacity, across iterations and reference years (MW).","examples":["1813.09","1717","13654.21","13663"],"is_float":true},"TOTALAVAILABLEGENMIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum available capacity, across iterations and reference years (MW).","examples":["1091.96","1183","10884.1","10007"],"is_float":true},"TOTALINTERMITTENTGEN10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10th percentile for intermittent generation, across iterations and reference years (MW)","examples":["10.14","58","1708.42","1392"],"is_float":true},"TOTALINTERMITTENTGEN50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50th percentile for intermittent generation, across iterations and reference years (MW)","examples":["106.65","140","2673.14","2099"],"is_float":true},"TOTALINTERMITTENTGEN90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90th percentile for intermittent generation, across iterations and reference years (MW)","examples":["233.34","448","4587.8","4242"],"is_float":true},"TOTALSCHEDULEDGEN10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10th percentile for scheduled generation across iterations and reference years (MW)","examples":["321.03","0","328","6106"],"is_float":true},"TOTALSCHEDULEDGEN50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50th percentile for scheduled generation across iterations and reference years (MW)","examples":["3.29","0","497","7416"],"is_float":true},"TOTALSCHEDULEDGEN90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90th percentile for scheduled generation across iterations and reference years (MW)","examples":["7.41","0","175","7630"],"is_float":true},"TOTALSEMISCHEDULEGEN10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 10% percentile for semi-scheduled generation across iterations and reference years (MW)","examples":["6.41","14","1631.88","514"],"name_in_csv":"TOTALSEMISCHEDULEDGEN10","is_float":true},"TOTALSEMISCHEDULEGEN50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 50% percentile for semi-scheduled generation across iterations and reference years (MW)","examples":["71.32","152","2542.13","2236"],"is_float":true},"TOTALSEMISCHEDULEGEN90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The 90% percentile for semi-scheduled generation across iterations and reference years (MW)","examples":["174.97","306","4328.96","3253"],"is_float":true},"USE_AVERAGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average unserved energy, across iterations and reference years (MW)","examples":["0.73","0","1.57"],"is_float":true},"USE_EVENT_AVERAGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average unserved energy event size, across iterations and reference years (MW)","examples":["440.72","0","472.26"],"is_float":true},"USE_LOWERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower quartile unserved energy, across iterations and reference years (MW)","examples":["0"],"is_float":true},"USE_MAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum unserved energy, across iterations and reference years (MW)","examples":["440.72","0","561.13"],"is_float":true},"USE_MEDIAN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Median unserved energy, across iterations and reference years (MW)","examples":["0"],"is_float":true},"USE_MIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum unserved energy, across iterations and reference years (MW)","examples":["0"],"is_float":true},"USE_NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Number of iterations and reference years with unserved energy>0","examples":["0","1","2"],"is_float":true},"USE_UPPERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Upper quartile unserved energy, across iterations and reference years (MW)","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONRESULT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":845231,"decompressed_size_all_time":727333290},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_REGIONSOLUTION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":6,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#703"],"comment":"MTPASA_CASESOLUTION is obsolete from 2017 End of Year DM4.27 Release.\nThe MTPASA_REGIONSOLUTION table shows the results of the regional capacity, maximum surplus reserve and maximum spare capacity evaluations for each day and ldcblock of the study.","description":"MTPASA_REGIONSOLUTION is public so is available to all participants.\n\nSource\n\nMTPASA_REGIONSOLUTION is updated each MTPASA run (i.e. weekly).\n\nVolume\n\nRows per week: 29400\n\nTo store only the latest solution, divide these figures by 5 (number of\nweeks per month rounded up).","unused":true,"primary_keys":["DAY","ENERGYBLOCK","LDCBLOCK","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this solution is for. Generated from the solution file periodid","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGYBLOCK":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Sunday at start of the week for this solutions energy block. Generated from the solution file energy block","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LDCBLOCK":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"LDC block this solution is for. Generated from the solution file periodid","examples":["1"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins","examples":["2018/05/01 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id. Generated from the solution file caseid","examples":["20"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":["RELIABILITY_LRC"]},"AGGREGATECAPACITYAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities offered by all Scheduled Generators in a given Region for a given PERIODID.","examples":["1820","15147"],"is_float":true},"AGGREGATEPASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Sum of PASAAVAILABILITY quantities offered by all Scheduled Generators in a given Region for a given PERIODID.","examples":["1820","15147"],"is_integer":true,"num_int_bits":64},"AGGREGATESCHEDULEDLOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities bid by of all Scheduled Loads in a given Region for a given PERIODID.","examples":["0"],"is_float":true},"CALCULATEDLOR1LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR1 used. Can be static value or calculated value if an interconnector is a credible contingency","is_float":true},"CALCULATEDLOR2LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR2 used. Can be static value or calculated value if an interconnector is a credible contingency","is_float":true},"CONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Region energy constrained MW capacity subject to energy and network security constraints","examples":["0","285","8645"],"is_integer":true,"num_int_bits":64},"DEFICITRESERVE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reserve deficit (MW)","examples":["76.428732","0","432.8090"],"is_float":true},"DEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Input value for 10% probability demand","examples":["1263.73","7006","14143.73","13473"],"is_float":true},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Input value for 50% probability demand","examples":["1168.36","6698","13082.32","8531"],"is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["1302.0020","1593","14369.0040","9497"],"is_float":true},"ENERGYREQDEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of: (Region Period Demand - given Demand10)/PeriodLength(sum by Energy Block, entered in first period of energy block, GWh)","examples":["167.07","0","220","1907.88"],"is_float":true},"ENERGYREQDEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of: (Region Period Demand - given Demand50)/PeriodLength (sum by Energy Block, entered in first period of energy block, GWh)","examples":["152.25","0","199","1751.81"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the solution was loaded","examples":["2018/05/01 12:31:15"],"parse_csv_as_string":true,"is_s_datetime":true},"LOR_SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Regional UIGF availability for LOR","examples":["0"],"is_float":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"The LOR Condition determined from the Maximum Spare Capacity value: 0 = no condition, 1 = LOR1 condition, 2 = LOR2 condition, 3 = LOR3 condition","is_integer":true,"unsigned_int":true,"num_int_bits":8},"LORNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the LOR assessment","is_float":true},"LORTOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the LOR assessment","is_float":true},"MAXSPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The Maximum Spare Capacity evaluated for this region in this period. Calculated for each region in turn","is_float":true},"MAXSURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The Maximum generation (MW) that could be withdrawn from this region without incurring a Low Reserve Condition.","is_float":true},"MAXUSEFULRESPONSE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The Maximum market response (MW) needed for the region to eliminate a Low Reserve Condition (LRC)","examples":["0"],"is_float":true},"MSRNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the MSR assessment","is_float":true},"MURNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the MRR assessment","is_float":true},"NETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated in capacity adequacy evaluation: Export if > 0, Import if < 0.","examples":["-330.45","0.45","0","330"],"is_float":true},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"The regional reserve condition: 0 = Adequate, 1 = LRC","examples":["0","1"],"is_integer":true,"num_int_bits":8},"SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Regional UIGF availability","examples":["1.76","0","109.74"],"is_float":true},"SURPLUSCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional surplus capacity MW, +/- values indicate surplus/deficit capacity","examples":["-6.72","14.6","-368","4163"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["34.821","422","244.154","428"],"is_float":true},"UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["1.76","0","109.74"],"is_float":true},"UNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Region energy unconstrained MW capacity subject to network security constraints","examples":["985","10482"],"is_integer":true,"num_int_bits":64},"CAPACITYREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used from 21/05/2010. Prior to 21/05/2010: CA Demand + Reserve Requirement","unused":true,"is_float":true},"RESERVEREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used from 21/05/2010. Prior to 21/05/2010: Input reserve requirement","unused":true,"is_float":true},"SURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used from 21/05/2010. Prior to 21/05/2010: Regional reserve surplus. +/-0 values indicate surplus/deficit reserve","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2018/MMSDM_2018_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MTPASA_REGIONSOLUTION_201805010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2018,"month":5},"compressed_size_per_month":326266,"decompressed_size_all_time":265421100},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_REGIONSUMMARY":{"package":"MTPASA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"REGIONSUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec39.htm#69"],"comment":"Region Results summary over aggregation periods.","description":"MTPASA_REGIONSUMMARY is public data.","primary_keys":["AGGREGATION_PERIOD","DEMAND_POE_TYPE","PERIOD_ENDING","REGIONID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"AGGREGATION_PERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Period data is aggregated over. Values are YEAR, MONTH","examples":["MONTH","YEAR"]},"DEMAND_POE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Demand POE type used. Value are POE10, POE50","examples":["POE10","POE50"]},"PERIOD_ENDING":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime of day at end of period (i.e. last day of month or year reported)","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins.","examples":["2026/09/07 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run id.","examples":["1177","1184"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Always RELIABILITY","examples":["RELIABILITY"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/08 12:29:02"],"parse_csv_as_string":true,"is_s_datetime":true},"LRC":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"LRC Condition reported (Value=1) if USE_WEIGHTED_AVG >= 0.002% otherwise (Value=0)","examples":["0","1"],"is_float":true},"NATIVEDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Native demand calculated from Operational As Generated trace supplied by Energy Forecasting","examples":["117314.69","869504","72933777.98","4547386"],"is_float":true},"NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Total number of iterations and reference years performed","examples":["600"],"is_float":true},"USE_AVERAGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average period unserved energy across iterations and reference years (MWh)","examples":["0.01","0","17","3988.47"],"is_float":true},"USE_EVENT_LOWERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower quartile unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","108","221"],"is_float":true},"USE_EVENT_MAX":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","669","4177.01"],"is_float":true},"USE_EVENT_MEDIAN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Median unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","1329.21"],"is_float":true},"USE_EVENT_MIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["0.13","0","521.41"],"is_float":true},"USE_EVENT_UPPERQUARTILE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Upper quartile unserved energy event size across all half hourly intervals and iterations and reference years that have unserved energy>0 (MW)","examples":["1.7","0","1908.27"],"is_float":true},"USE_NUMBEROFITERATIONS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Number of iterations and reference years showing unserved energy","examples":["0","1","57"],"is_float":true},"USE_PERCENTILE10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 10th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE20":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 20th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE30":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 30th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE40":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 40th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 50th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE60":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 60th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE70":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 70th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE80":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 80th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 90th percentile of iterations and reference years (MWh)","examples":["0"],"is_float":true},"USE_PERCENTILE100":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unserved energy period amount at the 100th percentile of iterations and reference years (MWh)","examples":["0.85","0","580","24241"],"is_float":true},"USE_WEIGHTED_AVG":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Weighted average USE per region = (USE_AVERAGE_POE10/NATIVE_DEMAND_POE_10*WEIGHT_POE_10 + USE_AVERAGE_POE50/NATIVE_DEMAND_POE_50*WEIGHT_POE_50)*100","examples":["0.000001","0","0.059534"],"is_float":true},"WEIGHT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed Values of 0.696 for 50 POE and 0.304 for 10 POE.","examples":["0.304","0.392"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_REGIONSUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2018,"month":5},"last_month":{"year":2026,"month":9},"compressed_size_per_month":15684,"decompressed_size_all_time":26946360},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_RESERVELIMIT":{"package":"RESERVE_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"RESERVELIMIT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec52.htm#1"],"comment":"MT PASA input table defining a MT PASA Reserve Requirement within a single set. An MT PASA Reserve Requirement can span more than one region.","description":"Source\n\nMTPASA_RESERVELIMIT is updated on an ad hoc basis when a new Reserve\nRequirement is published.\n\nVolume\n\n~20 rows per year","primary_keys":["EFFECTIVEDATE","RESERVELIMITID","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trade date when the set of reserve requirements become effective","examples":["2010/04/22 00:00:00"],"parse_csv_as_string":true,"is_date":true},"RESERVELIMITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"MT PASA Reserve Requirement identifier","examples":["MTPASAMRL01_NSW1","MTPASAMRL01_QLD1","MTPASAMRL01_SA1","MTPASAMRL01_TAS1","MTPASAMRL01_VIC1","MTPASAMRL01_VICSA_01","MTPASAMRL01_VICSA_02","MTPASAMRL01_VICSA_03","MTPASAMRL01_VICSA_04","MTPASAMRL01_VICSA_05","MTPASAMRL01_VICSA_06","MTPASAMRL02_Q-N_01","MTPASAMRL02_Q-N_02","MTPASAMRL02_Q-N_03","MTPASAMRL02_Q-N_04","MTPASAMRL02_Q-N_05","MTPASAMRL02_Q-N_06","MTPASAMRL02_TAS1","MTPASAMRL02_VICSA_01","MTPASAMRL02_VICSA_02","MTPASAMRL02_VICSA_03","MTPASAMRL02_VICSA_04","MTPASAMRL02_VICSA_05","MTPASAMRL02_VICSA_06"]},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Timestamp when the set of reserve requirements become effective","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true},"DESCRIPTION":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Description of this Reserve Requirement","examples":["Dynamic MRL for VIC1-SA1 - 2010/11","Dynamic MRL for VIC1-SA1 - 2011/12","File1 Dynamic MRL for VIC1-SA1 - 2011/12","File1 Initial MRL for NSW1 - 2011/12","File1 Initial MRL for QLD1 - 2011/12","File1 Initial MRL for TAS1 - 2011/12","File2 Dynamic MRL for QLD1-NSW1 - 2013/14","File2 Dynamic MRL for VIC1-SA1 - 2013/14","File2 Static MRL for 2013/14","Initial MRL for NSW1","Initial MRL for NSW1 - 2010/11","Initial MRL for NSW1 - 2011/12","Initial MRL for QLD1","Initial MRL for QLD1 - 2010/11","Initial MRL for QLD1 - 2011/12","Initial MRL for SA1","Initial MRL for SA1 - 2010/11","Initial MRL for SA1 - 2011/12","Initial MRL for TAS1","Initial MRL for TAS1 - 2010/11","Initial MRL for TAS1 - 2011/12","Initial MRL for VIC1","Initial MRL for VIC1 - 2010/11","Initial MRL for VIC1 - 2011/12","Shared MRL for VIC1-SA1 - 2010/11","Shared MRL for VIC1-SA1 - 2011/12"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp the record was last modified.","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true},"RHS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Right hand side value for this Reserve requirement","examples":["-40.53","128.13","-50","3840"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_RESERVELIMIT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1454,"decompressed_size_all_time":1935390},"visibility":"Public","trigger":"Ad hoc, when a new Reserve Requirement is published"},"MTPASA_RESERVELIMITSOLUTION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"RESERVELIMITSOLUTION","VERSION":1,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#712"],"comment":"MTPASA_RESERVELIMITSOLUTION is obsolete from 2017 End of Year DM4.27 Release.\nMT PASA Solution table reporting whether a MT PASA Reserve requirement is binding for each day and LDC block of the run.","description":"Source\n\nMTPASA_RESERVELIMITSOLUTION is updated each MTPASA run (i.e. weekly).\n\nVolume\n\n400,000 rows per year","unused":true,"primary_keys":["DAY","ENERGYBLOCK","LDCBLOCK","RESERVELIMITID","RUN_DATETIME","RUN_NO","RUNTYPE"],"columns":{"DAY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Day this solution is for. Generated from the solution file period id.","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGYBLOCK":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Sunday at start of the week for this solutions energy block. Generated from the solution file energy block.","examples":["2018/05/06 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LDCBLOCK":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Load Duration Curve block this solution is for. Generated from the solution file period id.","examples":["1"],"is_integer":true,"num_int_bits":16},"RESERVELIMITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The unique identifier of the MT PASA LRC Reserve Requirement.","examples":["MTPASAMRL01_NSW1","MTPASAMRL01_QLD1","MTPASAMRL01_TAS1","MTPASAMRL01_VICSA_01","MTPASAMRL01_VICSA_02","MTPASAMRL01_VICSA_03","MTPASAMRL01_VICSA_04","MTPASAMRL01_VICSA_05","MTPASAMRL01_VICSA_06"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date processing of the run begins","examples":["2018/05/01 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_NO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique run ID. Generated from the solution file Case ID.","examples":["20"],"is_integer":true,"num_int_bits":16},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":["RELIABILITY_LRC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp the record was last modified.","examples":["2018/05/01 12:31:15"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal Value of the Reserve Requirement Constraint. A non-zero value indicates that the reserve requirement is binding.","examples":["-75.493070","0","-14491.154403"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2018/MMSDM_2018_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_MTPASA_RESERVELIMITSOLUTION_201805010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2018,"month":5},"compressed_size_per_month":42304,"decompressed_size_all_time":42527090},"visibility":"Public","trigger":"On MTPASA solution published to the market (usually once per week)"},"MTPASA_RESERVELIMIT_REGION":{"package":"RESERVE_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"RESERVELIMIT_REGION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec52.htm#8"],"comment":"MT PASA input table to define the regions that are part of a single MT PASA Reserve Requirement","description":"Source\n\nMTPASA_RESERVELIMIT_REGION is updated on an ad hoc basis when a new\nReserve Requirement is published.\n\nVolume\n\n~50 rows per year","primary_keys":["EFFECTIVEDATE","REGIONID","RESERVELIMITID","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trade date when the set of reserve requirements become effective","examples":["2010/04/22 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID - identifier of a NEM region included in this requirement","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RESERVELIMITID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"MT PASA Reserve requirement identifier","examples":["MTPASAMRL01_NSW1","MTPASAMRL01_QLD1","MTPASAMRL01_SA1","MTPASAMRL01_TAS1","MTPASAMRL01_VIC1","MTPASAMRL01_VICSA_01","MTPASAMRL01_VICSA_02","MTPASAMRL01_VICSA_03","MTPASAMRL01_VICSA_04","MTPASAMRL01_VICSA_05","MTPASAMRL01_VICSA_06","MTPASAMRL02_Q-N_01","MTPASAMRL02_Q-N_02","MTPASAMRL02_Q-N_03","MTPASAMRL02_Q-N_04","MTPASAMRL02_Q-N_05","MTPASAMRL02_Q-N_06","MTPASAMRL02_TAS1","MTPASAMRL02_VICSA_01","MTPASAMRL02_VICSA_02","MTPASAMRL02_VICSA_03","MTPASAMRL02_VICSA_04","MTPASAMRL02_VICSA_05","MTPASAMRL02_VICSA_06"]},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Timestamp when the set of reserve requirements become effective","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true},"COEF":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Coefficient for the region in this reserve requirement","examples":["0.144","1","48.44"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp the record was last modified","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_RESERVELIMIT_REGION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1254,"decompressed_size_all_time":1617300},"visibility":"Public","trigger":"Ad hoc, when a new Reserve Requirement is published"},"MTPASA_RESERVELIMIT_SET":{"package":"RESERVE_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"MTPASA","REPORT_SUB_TYPE":"RESERVELIMIT_SET","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec52.htm#15"],"comment":"MT PASA input table defining a set of MT PASA Reserve Requirements. Note only one set can be active on a given date.","description":"Source\n\nMTPASA_RESERVELIMIT_SET is updated on an ad hoc basis when a new Reserve\nRequirement is published.\n\nVolume\n\n~2 rows per year","primary_keys":["EFFECTIVEDATE","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trade date when the set of reserve requirements become effective","examples":["2010/04/22 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Timestamp when the set of reserve requirements become effective","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"User authorising this requirement set","examples":["ABRAHAM","JACKZ","JEFFP","KINW"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date the requirement set was authorised","examples":["2010/05/20 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DESCRIPTION":{"sql_type":"VARCHAR2(200)","pl_type":"str","mandatory":false,"comment":"Description of this set of Reserve Requirements","examples":["Initial MRL","Initial and Dynamic MRL","Initial and Shared MRL","MRL (2013 Mid)"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp the record was last modified","examples":["2010/05/20 15:55:46"],"parse_csv_as_string":true,"is_s_datetime":true},"RESERVELIMIT_SET_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"MT PASA LRC Reserve Requirement Set Identifier","examples":["MTPASAMRL01","MTPASAMRL_2013Mid"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23MTPASA_RESERVELIMIT_SET%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":711,"decompressed_size_all_time":958090},"visibility":"Public","trigger":"Ad hoc, when a new Reserve Requirement is published"},"NEGATIVE_RESIDUE":{"package":"DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"NEGATIVE_RESIDUE","VERSION":1},{"REPORT_NAME":"DISPATCH","REPORT_SUB_TYPE":"NEGATIVE_RESIDUE","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec23.htm#181"],"comment":"Shows the inputs provided to the Negative Residue Constraints in the Dispatch horizon","primary_keys":["DIRECTIONAL_INTERCONNECTORID","NRM_DATETIME","SETTLEMENTDATE"],"indexes":[["SETTLEMENTDATE","NRM_DATETIME","DIRECTIONAL_INTERCONNECTORID"]],"columns":{"DIRECTIONAL_INTERCONNECTORID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Negative residue related direction interconnector id","examples":["NSW1_QLD1","NSW1_VIC1","QLD1_NSW1","SA1_VIC1","TAS1_VIC1","VIC1_NSW1","VIC1_SA1","VIC1_TAS1"]},"NRM_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The time that residue information is processed","examples":["2026/08/31 23:55:24"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch Interval","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CUMUL_NEGRESIDUE_AMOUNT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Negative residue triggering amount","examples":["-0.14","0","-33525.75"],"is_float":true},"CUMUL_NEGRESIDUE_PREV_TI":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Previous trading interval cumulative negative residue amount","examples":["-0.17","0","-26187.44"],"is_float":true},"DI_NOTBINDING_COUNT":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Count of the number of DIs not binding by this constraint","examples":["3"],"is_integer":true,"num_int_bits":8},"DI_VIOLATED_COUNT":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Count of the number of DIs violated by this constraint","examples":["0"],"is_integer":true,"num_int_bits":8},"EVENT_ACTIVATED_DI":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The starting DI when NRM event is active","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EVENT_DEACTIVATED_DI":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The finishing DI when NRM event stops being active.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEGRESIDUE_CURRENT_TI":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Current trading interval negative residue amount","examples":["-0.14","0","-14329","-20116.1"],"is_float":true},"NEGRESIDUE_PD_NEXT_TI":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The cumulative negative residue for the next trading interval (PD)","examples":["-0.33","0","-4610","-5856.66"],"is_float":true},"NRM_ACTIVATED_FLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Is 1 if negative residue process is on, else is 0","examples":["0"],"is_integer":true,"num_int_bits":8},"NRM_LOOP_FLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"NRM Loop Flag controls monitoring behaviour:\n0 = Individual NRM monitoring suppressed (loop operational with aggregate IRSR >= 0)\n1 = Individual NRM monitoring active (applies to: loop not operational, aggregate loop IRSR < 0, or non-loop interconnection)\nThis flag is evaluated and set for ALL interconnections in each dispatch interval","is_boolean":true},"NRMCONSTRAINT_BLOCKED_FLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"1 if constraint is blocked, else 0","is_integer":true,"num_int_bits":8},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Predispatch sequence number","examples":["2026083140","2026090112"],"unsigned_int":true,"num_int_bits":32},"PRICE_REVISION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"SubjectToReview, Indeterminate, Accepted or Rejected"}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NEGATIVE_RESIDUE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":400143,"decompressed_size_all_time":78492220},"visibility":"Public"},"NETWORK_EQUIPMENTDETAIL":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"EQUIPMENTDETAIL","VERSION":1},{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"EQUIPMENTDETAIL","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#1"],"comment":"NETWORK_EQUIPMENTDETAIL Provides details on equipment that may have outages or ratings. A single piece of equipment may have multiple records if its details change.\nA line will typically have at least two valid records at a time, once for each end of the line.","primary_keys":["ELEMENTID","EQUIPMENTID","EQUIPMENTTYPE","SUBSTATIONID","VALIDFROM"],"indexes":[["LASTCHANGED"]],"columns":{"ELEMENTID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Equipment element id","examples":["3","3111"],"is_integer":true,"num_int_bits":64},"EQUIPMENTID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"A unique identifier for this type of equipment at this substation","examples":["1","110KV_714","7217","110KV_717","110KV_721","110KV_722","110KV_731","110KV_732","110KV_733","110KV_734","110KV_737","110KV_740","110KV_741","110KV_745/1","110KV_746/1","110KV_746/2","110KV_754","110KV_757","110KV_762","110KV_F826","110KV_F830","110KV_F833","110KV_F904/2","110KV_F912","110KV_F913","132KV_7110/3","132KV_7117/2","132KV_7121","132KV_7122/2","132KV_7122/3","132KV_7124/1","132KV_71252","132KV_7150/2","132KV_7155","132KV_7168","132KV_7171","132KV_7185","132KV_7199","132KV_7200/1","132KV_7200/2","132KV_7226","132KV_7227/1","132KV_7227/3","132KV_7241","132KV_7243","132KV_7253","132KV_747/1","132KV_747/2","132KV_786","132KV_795/2","132KV_795/3","1BCAP_66","1CAP","1CAP_1B_22","1CAP_1B_220","1CAP_1B_66","1CAP_22","1CAP_275","1CAP_330","1CAP_66","1GN2","1GTR","1MN1","1TR","1_BANK_SSCVL","1_BT_T4","1_GEN_H55","1_GEN_SSRPT","1_H11","1_H18","1_H36","1_STN_T104","1_T105","1_T12","1_T131","1_T24","1_T36","1_T37","1_T46","1_T47","1_T53","1_T55","1_T69","1_T75","1_T97","1_TFMR_H32","275KV_816","275KV_823","275KV_824","275KV_831","275KV_832","275KV_843","275KV_844","275KV_857","275KV_8814","275KV_8815","2BCAP_2B_66","2BN","2BS","2CAP_22","2CAP_2B","2CAP_2B_22","2CAP_2B_66","2CAP_330","2CAP_4XN_66","2CS","2GTR","2MN1","2MN2","2MN3","2_BANK_T108","2_GE_OAK","2_H16","2_H18","2_H5","2_H6","2_H8","2_R2","2_SSBRD","2_SSHIL","2_STN_TFMR_T5","2_T13","2_T134","2_T136","2_T21","2_T24","2_T32","2_T39","2_T47","2_T53","2_T56","2_T65","330KV_9905","330KV_9906","3ACAP_66","3BCAP_66","3CAP_3B_220","3CAP_3B_66","3GTR","3MN1","3MN2","3MN3","3MN4","3MN5","3MN6","3_GEN_H27","3_GEN_T22","3_H14","3_H4","3_SSCVL","3_SSDBS","3_T136","3_T51","3_WED","4BCAP_66","4CAP","4CAP_4B_66","4MN3","4_GEN_H33","4_GEN_T37","4_SSSFD","4_TFMR_H13","5GTR","5MN1","5_GEN_H7","5_SSVPK","5_T8","66KV_601","6MN1","6MN2","6MN3","6MN4","6_H9","6_SSMDH","6_T8","7M1A","7MN1","7MN2","7MN3","7MN4","7MN6","7XN1","858_H32","8810_H24","8L","9901_R3","A","A1_TR","A2GTR","A2REAC","A2_TR","ABBPTA_1","AL_BLTS_66","ATS_KTS_220","ATS_TYA_66","B-H","B1TR","B2TR","B3TR","BLTS_LVN_66","BLTS_TYA_66","BTS_TTS3_220","CAP","CAP_4B_66","EPS_MBTS1_220","E_BANK_SSCST","GNTS_SHTS3_220","HPS_WOTS_66","HY2REAC","HYTS2_2REAC","HYTS_MLTS1_500","HYTS_SESS2_275","J1TR","JLA_TBTS1_220","KESPLY_T","KTS_TTS2_220","L5TR","L6TR","LY_MWTS1_66","LY_MWTS4_66","M1TR","MGUPLA_T","MLTS_SYTS1_500","MTS_ROTS1_220","MTS_ROTS3_220","N/A","NOFDCK_1","NOWLIP_1","OAKSEA_1","PEWLAG_1","PIMPLA_T","PLAYNPS_1","PLYGLN_1","PPIBUN33","PPTGT12","PPTPGW_1","ROBNWB_1","TABKEI_1","TOAKIL66","TOAMAG_1","W1TR","X1","X2","Y2TR","Z12","Z13"]},"EQUIPMENTTYPE":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of equipment. Valid values are:\nLINE = Line\nTRANS = Transformer\nCB = Circuit breaker\nISOL = Isolator\nCAP = Capacitor\nREAC = Reactor\nUNIT = Unit","examples":["BUS","CAP","LINE","N/A","REAC","SVC","TRANS"]},"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"ID uniquely identifying the substation this equipment is located at","examples":["ABC_B","AC","AL","ALDING","APD","ATS","BATS","BDSS","BETS","BLTS","BRT","BTS","BUNGAM","CAL_A_PS","CLPS","CRAIGLIE","DDTS","DRY_CK","DUMARESQ","ELIZ_H","EPS","ERTS","FBTS","GLAD_PS","GLEN_N","GNTS","GTS","H10_BCMB","H11_NEBO","H12_MT_E","H13_ROSS","H14_MRDG","H15_LILY","H16_RLEA","H18_TRNG","H22_LOGN","H23_UKED","H24_CALV","H29_STAN","H2_SPINE","H32_CHLM","H35_STHM","H36_BLKW","H39_WORE","H3_BELMT","H4_MUGBA","H51_SBKE","H5_WLGA","H6_GNGN","H7_GLAD","H8_BOYNE","H9_PLMWD","HOTS","HTS","HUME","HWPS","HWTS","HYTS","JLA","JLGSA","JLTS","KAR_H_PS","KEITH","KGTS","KILBUR","KTS","LADB_G","LIN_PK","LVN","LY","LYPA","LYPS","MAGILL","MBTS","MILLM_PS","MLRC","MLTS","MPS","MTS","MT_GUN","MT_S_PS","MWTS","N/A","NORTHF","NORWD","NPS","NPSD","N_RICH","N_W_B","OAKEY_PS","OAKLND","PARA","PELI_P","PEL_PS","PENFLD","PENO_W","PGWEST","PIMBA","PLAY","PLMGPTEE","PLYMPT","PTH","PT_NOA","P_ADEL","P_PIRI","R2_BRAE","R3_BULLI","R4_MILLM","RCTS","ROTS","RTS","RWTS","R_TOWN","SBK_D_PS","SBK_E_PS","SEACOM","SHTS","SMTS","SSAST","SSBBH","SSBHD","SSBPN","SSBRD","SSBWH","SSCST","SSCVL","SSDBS","SSHIL","SSIBS","SSMDH","SSMLB","SSMLT","SSMST","SSNGE","SSRPT_PS","SSRVW","SSS","SSSFD","SSSPD","SSSPO","SSVPK","SSWED","STAN_PS","SVTS","SYTS","S_EAST","T104_STN","T105_OON","T108_BNL","T10_YARR","T110_PKD","T111_NOR","T11_CBLT","T124_TRV","T128_RBA","T12_KILK","T131_ISI","T134_CDW","T136_ABM","T137_NGY","T139_BDN","T13_CHIN","T142_TEN","T145_TVL","T147_TAN","T150_ASH","T152_G_S","T155_WDR","T16_NAMB","T174_TRA","T187_RLD","T20_BUND","T21_QAL","T22_CALL","T24_RUNC","T26_BILO","T27_MRA","T2_DALBY","T30_ASHW","T31_BRAL","T32_BWTR","T34_MRNB","T35_DYST","T36_INVA","T37_COLL","T38_MKAY","T39_PROS","T40_IFLT","T46_GARB","T47_INGM","T48_TLLY","T4_SBK_A","T51_CRNS","T53_KAM","T55_TURK","T56_TV_S","T5_GLAD","T65_ALCK","T69_NLDS","T70_CORY","T71_CLMT","T75_NRNG","T78_LOCK","T80_REDB","T81_CADE","T8_GYMP","T93_CLS","T97_GREG","T98_DNGO","T99_GRNT","TBTS","TGTS","TIPS_A","TIPS_B","TRNG_PS","TSTS","TTS","TVLLE_PS","TYA","T_BEND","VPGS","WIN","WIV_PS","WKPS","WMTS","WN","WOTS","YPS"]},"VALIDFROM":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date that this record is applies from (inclusive)","examples":["2003/04/28 16:51:08.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"DESCRIPTION":{"sql_type":"VARCHAR(100)","pl_type":"str","mandatory":false,"comment":"A short description for this equipment.","examples":["Abermain 2 100/33kV XFMR","Abermain 3 100/33kV XFMR","Abermain 3 110kV BUS","Alan Shrff 11kV BUS","Alc/prtlnd 1 220kV BUS","Alc/prtlnd 2 500kV BUS","Alc/prtlnd 2 500kV REACT","Alc/prtlnd 3 500kV BUS","Alc/prtlnd 33kV BUS","Alc/prtlnd A2 33kV REACT","Alc/prtlnd W1 220/33kV XFMR","Aldinga 66kV","Aligator Creek 132kV","Aligatr Ck 1 132/33kV XFMR","Aligatr Ck 2 132/33kV XFMR","Aligatr Ck 2 132kV BUS","Alligator Creek 132kV","Altona 220kV","Altona 66kV BUS","Altona Brooklyn 66kV LINE","Altona Brooklyn66kV LINE","Altona Chemicals 66kV","Altona Chm 66kV BUS","Altona220 2 66kV BUS","Altona220 Keilor 220kV LINE","Altona220 Keilor220kV LINE","Altona220 Laverton 66kV LINE","Altona220 Laverton66kV LINE","Altona220 Toyota 66kV LINE","Altona220 Toyota66kV LINE","Angas Creek 132kV","Angle Vale 66kV","Anglesea Ps 220kV","Anm 132kV","Ann Street City 110kV","Ardrossan West 132kV","Armidale/gleninnes/tenterfield 132kV Tee","Ascot Park 66kV","Ashgrove W 3 110kV BUS","BHP Ardrossan Term.","Bald Hills 110kV","Ballarat 220kV","Ballart220 2 66kV BUS","Ballart220 Horsham 220kV LINE","Ballart220 Horsham220kV LINE","Balranald 220/22kV Substation","Baralaba 2 132kV BUS","Barcaldine 132kV","Barnsdl PS B-H 66kV BUS","Bayswater 330kV","Beaconsfield 330kV","Beenleigh 110kV","Beenleigh 2 33kV CAP","Beerwah","Beerwah 110kV BUS","Belmont 1 275kV BUS","Belmont 2 110kV BUS","Belmont 275kV","Bendigo 2 22kV BUS","Bendigo 2 66kV CAP","Bendigo 3B 66kV CAP","Biloela 132kV Tee","Biloela 2 132kV BUS","Blackwall 1 275kV SVC","Blackwall 275kV","Blackwater 2 132/69kV XFMR","Blackwood 66kV","Blanch 132kV","Blowering Ps 132kV","Blue Lake","Bouldercmb 1 132kV BUS","Bouldercmb 1 275kV BUS","Bouldercmb 2 275kV BUS","Bouldercmb 4 132kV BUS","Boyne Isld 1 132kV BUS","Boyne Isld 2 132kV BUS","Boyne Isld 2 275/132kV XFMR","Braemar 2 275kV BUS","Braemar 2 330/275kV XFMR","Braemar 330kV/275kv","Brendale 2 110/33kV XFMR","Bright 66kV","Bright 66kV BUS","Broadbeach 4 11kV BUS","Brooklyn 1 22kV BUS","Brooklyn 1 66kV BUS","Brooklyn 1A 220kV BUS","Brooklyn 4 220kV BUS","Brooklyn Laverton N 66kV LINE","Brooklyn Laverton N66kV LINE","Brooklyn Toyota 66kV LINE","Brooklyn Toyota66kV LINE","Brunswick 1 22kV CAP","Brunswick 220kV","Brunswick Thomastown 3 220kV LINE","Brwns Plns 110kV BUS","Bulli Ck 9901 330kV REACT","Bulli Creek 330kV","Bundaberg 132kV","Bungama 132kV","Bunnerong 132kV","Burnside 66kV","Buronga 220kV","Burrinjuck 132kV","Burton Downs 132kV","Caboolture 110kV Tee","Cades Cnty 1 11kV BUS","Cades County 110kV","Cairns 1 132kV BUS","Cairns 132kV","Cairns 22kV BUS","Cairns 3 132/22kV XFMR","Calld A PS 3G 11kV BUS","Callide 2 132kV BUS","Callide 3 132/11kV XFMR","Callide 4 132kV BUS","Callide 5 132kV BUS","Callide C Ps 275kV","Calvale 275kV","Calvale 8810 275kV REACT","Camperdown 66kV","Cardwell 1 22kV BUS","Cardwell 2 132/22kV XFMR","Chalumbin 1 19kV REACT","Chalumbin 858 275kV REACT","Chalumbin Woree 7217 132kV LINE","Charlotte St. 110kV","Charltt St 1 110kV BUS","Charltt St Ann St Cty F833 110kV LINE","Charltt St E 11kV CAP","Charltt St W End F830 110kV LINE","Cheltenham 66kV","Cherry Gardens 275kV","Chinchilla 132kV","Chinchilla 2 109/33kV XFMR","Chinchilla 33kV BUS","Chinchilla 4 110kV BUS","Clare 1 132kV BUS","Clare 2 132kV BUS","Clare South 132kV","Clearview 66kV","Clermont 1 132kV BUS","Clermont 132kV BUS 1","Cleveland 1 33kV BUS","Cleveland 1 33kV CAP","Cleveland 3 110/33kV XFMR","Clover PS 1 66/11kV XFMR","Coleambally 132kV","Collinsville 132kV","Collinsvll 1 138/11kV XFMR","Collinsvll 2 138/11kV XFMR","Collinsvll 2A 132kV BUS","Collinsvll 33kV BUS","Collinsvll 4 138/11kV XFMR","Collinsvll Newlands 7121 132kV LINE","Cooma (old) 132kV","Cooma 132kV","Cooroy 2 132kV BUS","Cooroy Image Flat 795/2 132kV LINE","Coppabella 132kV","Coppabella 132kV Tee","Coromandel Pl 66kV","Craiglie 132kV","Craiglie Turkinje 7200 132kV LINE","Croydon Park 66kV","Croytee/n_adel/hind_s 66kV Tee","Cultana 275kV","Dalby 1 110kV BUS","Dalby 2 100/33kV XFMR","Dan Gleeson 132kV","Dederang 1 330kV BUS","Dederang 1 330kV CAP","Dederang 2 220kV BUS","Dederang 2 330kV CAP","Dingo 132kV BUS","Doboy 110kV","Doboy 3 110/33kV XFMR","Dry Creek 66kV","Dry_ck/kilb_s/prosp 66kV Tee","Dumaresq 330kV","Dumresq330 Bulli Ck 8L 330kV LINE","Duncan Blg","Dysart 66kV BUS","Dysart Nrwch_Pk-T 7150/2 132kV LINE","E Rowville 1 220kV BUS","E Rowville 1 66kV CAP","E Rowville 3 66kV CAP","E Rowville 4 66kV BUS","E Rowville Tyabb 2 220kV LINE","East Rowville 220kV","Egans Hill 132kV","Eildon PS 2 225/11kV XFMR","Eildon PS Mt Beauty 1 220kV LINE","Eildon Ps 220kV","Elizabeth Downs 66kV","Eraring 500kV","Finley 132kV","Fishermans Bend 220kV","Flinders Park 66kV","Fshmns Bnd 2 66kV BUS","Fshmns Bnd 4 220kV CAP","Fshmns Bnd 66kV BUS","Fshmns Bnd 66kV No 3 BUS","Gadara 132kV","Garbutt 1 132/69kV XFMR","Garbutt 132kV","Geelong 1 66kV BUS","Geelong 2 220kV BUS","Geelong 220kV","Geelong 4 66kV CAP","Geelong 5 66kV BUS","Geelong 6 66kV BUS","Gin Gin 2 275/132kV XFMR","Gin Gin Bundaberg 786 132kV LINE","Gin Gin Woolooga 816 275kV LINE","Gladstn132 2 132kV BUS","Gladstn132 Gladstn PS 2 6kV LINE","Gladstn275 1 275kV BUS","Gladstn275 2 275kV BUS","Gladstn275 5 300/16kV XFMR","Gladston S 1 132kV BUS","Gladstone 132kV","Glenelg North 66kV","Glenrowan 1 66kV BUS","Glenrowan 220kV","Glenrowan Shepparton 3 220kV LINE","Golden Grove 66kV","Gosford 132kV","Gregory 1 132kV SVC","Gregory 132kV BUS","GrenFell Centre","Griffith 132kV","Guthega","Gympie 132kV","Gympie 2 132kV BUS","Gympie 5 132/33kV XFMR","Gympie 6 132/11kV XFMR","Gympie Traveston 747/1 132kV LINE","H23 Upper Kedron 110kV","Happy Valley 275kV","Haymarket 330kV","Hays Inlet 110kV","Hays Inlet 2 110/33kV XFMR","Hazelwd PS 1 220kV BUS","Hazelwd PS 2 230/16kV XFMR","Hazelwd PS 3 230/16kV XFMR","Hazelwd PS 6 220kV BUS","Hazelwd PS Rowvill220 3 220kV LINE","Hazelwood 1 500kV BUS","Hazelwood 3 500kV BUS","Hazelwood 4 500kV BUS","Heatherton 1 220kV BUS","Heatherton 1 66kV BUS","Heatherton 1 66kV CAP","Heatherton 1B 66kV CAP","Heatherton 3 66kV BUS","Henley South 66kV","Heywood 1 275kV CAP","Heywood 500kV","Heywood M1 500/275kV XFMR","Heywood Moorabool 1 500kV LINE","Heywood S East 2 275kV LINE","Hillcrest 66kV","Holden Hill 66kV","Horsham 2 66kV CAP","Horsham 220kV","Hume PS Wodonga 66kV LINE","Hume PS Wodonga66kV LINE","Hume Ps 132kV","Hvewme 66kV","Ibis 110kV","Ibis 110kV Rocky Pt F904/2 110kV LINE","Image Flat Nambour 795/3 132kV LINE","Ingham 1 132/69kV XFMR","Ingham 132kV","Ingham 2 132/69kV XFMR","Ingham 2 132kV BUS","Ingham Townsville 7132 132kV LINE","Ingle Farm 66kV","Inisfail Kareeya PS 7137 132kV LINE","Invict Mll 1 132/11kV XFMR","Invicta Mill 132kV","Isis 132kV","Isis 132kV 1 132/66kV XFMR","Isis 132kV 66kV BUS","JLysaght 1 33kV BUS","JLysaght Tyabb 1 220kV LINE","Jeeralang 1 220kV BUS","Jeeralang 220kV","Jeeralang B Ps 220kV","Jinderra 330kV","John Martin 1","John martin 2","Jrlng A PS A1 230/10kV XFMR","Jrlng A PS A2 230/10kV XFMR","Kadina_East 132kV","Kamerunga 1 132/22kV XFMR","Kamerunga 132kV","Kamerunga 2 132/22kV XFMR","Kangaroo Valley Ps","Kanmantoo Mine","Kareeya PS Cardwell 71352 132kV LINE","Kareeya PS Tully 7253 132kV LINE","Kareeya Ps 132kV","Keilor 1 220kV BUS","Keilor 2 500kV BUS","Keilor 4 66kV BUS","Keilor B3 220/66kV XFMR","Keilor Thomastown 2 220kV LINE","Keith 132kV","Kemmis 132kV","Kemps Creek 500kV","Kerang 2 22kV BUS","Kerang 2 22kV CAP","Kerang 220kV","Kilburn South 66kV","Kilkenny 66kV","Kilkivan 1 132/66kV XFMR","Kilkivan Marybrgh-T 785/1 132kV LINE","Kincraig 132kV","Kurri 132kV","Kurri 132kV eA","Laverton 66kV","Laverton 66kV BUS","Laverton N 66kV BUS","Laverton North 66kV","Lefevre 66kV","Leigh Creek South","Lilyvale 1 132kV BUS","Lilyvale 1 19kV REACT","Lilyvale 1 288/138/19kV XFMR","Lilyvale 275kV","Lilyvale Gregory 7171 132kV LINE","Lismore 132kV","Lismore 330kV","Lockrose 2 110kV BUS","Loganlea 1S 33kV BUS","Loganlea 2 275kV BUS","Lower Tumut","Loy Yang 1 66kV CAP","Loy Yang Gas","Loy Yang Morwell 1 66kV LINE","Loy Yang Morwell 4 66kV LINE","Loy Yang Ps 500kV","Loy Yng Gs 1 220/11kV XFMR","Loy Yng Gs 5 220/11kV XFMR","Loy Yng PS 2 500kV BUS","LyYng A PS 2 500/24kV XFMR","Lytton 110kV Tee","Mackay 132kV","Magill 275kV","Makerston St 11 110/11/11kV XFMR 2","Makrstn St 2L2 110/11/11kV XFMR","Malvern 220kV","Malvern 3 210/22kV XFMR","Malvern 3 220kV BUS","Malvern 3 22kV BUS","Malvern Rowvill220 1 220kV LINE","Malvern Rowvill220 3 220kV LINE","Mannum-adelaide 2","Mannum-adelaide 3","Maroubra 132kV","MarrickVille 132kv","Marulan 330kV","Maryborogh Marybrgh-T 785/3 132kV LINE","Maryborough 132kV","Maryborough 132kV Tee","Meeandah 110kV","Meeandah 6 110/33kV XFMR","Midback 132kV","Middle Rdg 2 110kV BUS","Middle Rdg 3 275/110kV XFMR","Middle Rdg 4 110kV BUS","Middle Rdg 5 110kV BUS","Middle Rdg Tangkam 731 110kV LINE","Middle Rdg Tangkam 732 110kV LINE","Middle Rdg Yarranlea 733 110kV LINE","Middle Rdg Yarranlea 734 110kV LINE","Middle Ridge 275kV","Millbr 132kV","Miller Anderson","Millmerran Millmrn PS 9905 330kV LINE","Millmerran Millmrn PS 9906 330kV LINE","Milton 110kV","Milton 2 110kV BUS","Mintaro 132kV","Mobilong 132kV","Molendinar 4 100/33kV XFMR","Molendinar Southport F907 110kV LINE","Molendinar-Southport F907 110kV LINE","Molong 132kV","Monash 132kV","Moolloolaba 132kV","Mooloolaba 132kV","Moorabool 1 220kV BUS","Moorabool 2 500kV REACT","Moorabool Sydenham 1 500kV LINE","Moranbah 132kV","Moranbah Burton Dwn 7117/2 132kV LINE","Moranbah N_Gnyll-T 7122/2 132kV LINE","Moranbah Newlands 7155 132kV LINE","Moranbah Peak Dns-T 7124/1 132kV LINE","Morphettville 66kV","Morwell 1 22kV BUS","Morwell 1 230/66kV XFMR","Morwell 2 230/66kV XFMR","Morwell N2 66kV BUS","Morwell PS 1 11kV BUS","Morwell PS 1 22/11kV XFMR","Morwell PS 2 66/11kV XFMR","Morwell Ps 66kV","Mount Piper 330kV","Mount Piper 500kV","Mount Piper ps 330kV","Mount Stuart Ps","Moura 132kV","Moura Biloela-T 7110/3 132kV LINE","Mrrylnk Vc 1 220/165kV XFMR","Mrrylnk Vc Z 12 165kV CAP","Mrrylnk Vc Z 13 165kV CAP","Mt Beauty 220kV","Mt Druit 132kV","Mt England 1 275kV BUS","Mt England 2 275kV BUS","Mt England Blackwall 8813/2 275kV LINE","Mt England Wivenho PS 823 275kV LINE","Mt England Wivenho PS 824 275kV LINE","Mt Gambier West","Mt Mclaren 132kV","Mt Strt PS Townsvll S 7243 132kV LINE","Mt. England 275kV","Mt_Gunson PlyGnPmp-T 132kV LINE","Mt_Gunson PlyGnPmp-T132kV LINE","Mudgeeraba 275kV","Mudgeeraba 3 275/110kV XFMR","Mudgeeraba Burleigh 754 110kV LINE","Mudgeeraba Terranora 757 110kV LINE","Mullumbimby 132kV (northpower)","Munmorah Ps 330kV","Munmorah/sydnth/tuggerah 330kV Tee","Murray Bridge-hahndorf 2","Murraylink Sa","Murraylink Vic","Muswellbrook 132kV","Muswellbrook 330kV","Mwps1 132kV","Mwps2 132kV","Mwps3 132kV","Mwps4 132kV","N Gnyll Mn N_Gnyll-T 7122/3 132kV LINE","N_W_Bend Robertstwn 2 132kV LINE","Nambour 132kV","Nebo 1 275kV SVC","Nebo 2 132kV BUS","Nebo 2 288/138/19kV XFMR","Nebo 275kV","Nerang 1 110/11kV XFMR","Nerang 110kV","Neuroo 132kV","New Osborne 66kV","New Richmond 66kV","New Tennyson 110kV","New Tnnysn 1 33kV BUS","New Tnnysn 2 33kV BUS","New Tnnysn W End F905 110kV LINE","New_Rchmnd KesNRPly-T 66kV LINE","Newlands 1 132/69kV XFMR","Newstead   110kV","North Goonyalla Mine 132kV","North Unley 66kV","Northfield 275kV","Northfield Dry_Ck 66kV LINE","Northfield Dry_Ck66kV LINE","Norwich Park 132kV Tee","Norwood Linden_Pk 66kV LINE","Norwood Linden_Pk66kV LINE","Nth Goonyalla mine Tee","Nudgee 110kV","Nudgee Meeandah F805 110kV LINE","Nudgee Meeandah F806 110kV LINE","Nudgee Meeandah F912 110kV LINE","Nudgee Meeandah F913 110kV LINE","NwPrt D PS 2 220kV BUS","Oakey PS 2 115/10kV XFMR","Oaklands Seacombe 66kV LINE","Oaklands Seacombe66kV LINE","Oonooie 1 132kV SVC","Oonooie 132kV","Orange 132kV","Osbourne","Ourimbah 132kV","Palmwoods 275kV","Palmwoods 6 132/110kV XFMR","Palmwoods Cabooltr-T 746/2 110kV LINE","Palmwoods Mooloolaba 777 132kV LINE","Palmwoods Mooloolaba 778 132kV LINE","Panorama 132kV","Para 275kV","Para 275kV Elzbth_Hts 33kV LINE","Para 275kV Elzbth_Hts33kV LINE","Parafield Gardens 66kV","Parafield Gardens West 275kV","Paralowie 66kV","Peakhurst 132kV","Peln_ Pt Peln_Pt_PS GT12 275kV LINE","Peln_ Pt Prfd_Gdn_W 275kV LINE","Peln_ Pt Prfd_Gdn_W275kV LINE","Penfield 66kV","Penola 33/11kV","Penola West","Penola_W Ladbrk_Grv 132kV LINE","Penola_W Ladbrk_Grv132kV LINE","Pimba PlyGnPmp-T 132kV LINE","Pimba PlyGnPmp-T132kV LINE","Pioneer Valley 132kV","Play:mt_gun:pimba 132kV Tee","Playfod_PS Northrn_PS 132kV LINE","Playfod_PS Northrn_PS132kV LINE","Plympton 66kV","Plympton Glenelg_N 66kV LINE","Plympton Glenelg_N66kV LINE","Point Henry 220kV","Point Noarlunga 66kV","Point Stanvac 66kV","Port Lincoln 132kV","Port Lincoln City","Port Pirie 132kV","Postman's Ridge 110kV","Prfd_Gdn_W Penfield 66kV LINE","Prfd_Gdn_W Penfield66kV LINE","Prfd_Gdn_W Trrns_B_PS 275kV LINE","Prfd_Gdn_W Trrns_B_PS275kV LINE","Proserpine 2 132/69kV XFMR","Proserpine 66kV BUS","Proserpine Mackay 7125/2 132kV LINE","Proserpine Mackay 71252 132kV LINE","Prosp/nadeltee/croydn 66kV Tee","Prospect 66kV","Pstmns Rdg 3 106/33kV XFMR","Pstmns Rdg Middle Rdg 727 110kV LINE","Pstmns Rdg T 110kV BUS","Pt Henry 1 220kV BUS","Pt Henry 5 220/22kV XFMR","Pt Henry 6 220/22kV XFMR","Pt_Adel AdlBrtnCmt 66kV LINE","Pt_Adel AdlBrtnCmt66kV LINE","Pt_Noarlng Aldinga 66kV LINE","Pt_Noarlng Aldinga66kV LINE","Pt_Piri132 Bungama 33kV LINE","Pt_Piri132 Bungama33kV LINE","Qal  (qld. Aluminium) 132kV","Qal 2 132/11kV XFMR","Qal Gladston S 7101 132kV LINE","Queensland Alumina West","R5 Millmeran Ps","Red Cliffs 1 22kV CAP","Red Cliffs 2 22kV CAP","Red Cliffs 2 66kV CAP","Red Cliffs 220kV","Redbank 132kV","Richlands 110kV","Richlands 2 110kV BUS","Richmond 1 66kV BUS","Richmond 1 66kV CAP","Richmond 3 220kV BUS","Richmond 3 66kV BUS","Richmond 4 66kV CAP","Richmond 5 66kV BUS","Richmond BN 22kV BUS","Richmond BS 22kV BUS","Richmond CS 22kV BUS","Ringwood 2 66kV CAP","Ringwood 2B 66kV CAP","Ringwood 4 66kV BUS","Robertstwn N_W_Bend 132kV LINE","Robertstwn N_W_Bend132kV LINE","Robina 1 110/11kV XFMR","Robina Molendinar 7229 110kV LINE","Rockhampton 132kV","Rocklea 2 275/110kV XFMR","Rocky Point","Rocky Pt 1 110/11kV XFMR","Roma 132kV","Ross 275kV","Ross 275kV 2 132kV BUS","Ross 275kV 2 288/138/19kV XFMR","Ross 275kV 4 19kV REACT","Ross 275kV Chalumbin 857 275kV LINE","Rowvill220 2 220kV CAP","Rowvill500 1 500kV BUS","Runcorn 1 110/33kV XFMR","Runcorn 2 110/33kV XFMR","Runcorn Belmont 762 110kV LINE","S Morang 1 330kV BUS","S Morang 1 500kV BUS","S Pine 2 275/110kV XFMR","S Pine C 110kV BUS","S Pine Cabooltr-T 745/1 110kV LINE","S Pine Cabooltr-T 746/1 110kV LINE","S Pine Hays Inlet 741 110kV LINE","S Pine Nudgee 740 110kV LINE","S Pine Stafford 737 110kV LINE","S Pine Tarong 832 275kV LINE","S Pine Upr Kedron 721 110kV LINE","S Pine Upr Kedron 722 110kV LINE","Sheidow Park 66kV","Shepparton 2 220kV BUS","Shepparton 2 66kV BUS","Shepparton 3 66kV BUS","Shepparton 3A 66kV CAP","Shepparton 3B 66kV CAP","Somertn Sw 3 66kV BUS","Somerton Ps","South Pine 275kV","South_East Heywood. 2 275kV LINE","Southport 13 11kV BUS","Springvale 1 220kV BUS","Springvale 2 220kV BUS","Springvale 2 66kV BUS","Springvale 220kV","Springvale 3 66kV BUS","Springvale 6 66kV BUS","Srfrs Prds 1 11kV BUS","Srfrs Prds 4 11kV BUS","Srfrs Prds Broadbeach F826 110kV LINE","Stafford 4 110/33kV XFMR","Stan PS 4 300/21kV XFMR","Stan PS Ax 1 132/6kV XFMR","Stanwell 66kV","Stanwell Grantleigh 7185 132kV LINE","Stanwell Ps Aux","Stanwell Stan PS Ax 7199 132kV LINE","Strathmore 2 275kV BUS","Stroud 132kV","SwanBk A 1 275/110kV XFMR","SwanBk A Middle Rdg 712 110kV LINE","SwanBk A RedBk Plns 717 110kV LINE","SwanBk A Ssrvw 713 110kV LINE","SwanBk A Ssrvw 714 110kV LINE","SwanBk B Loganlea 804 275kV LINE","SwanBk E 3 275kV BUS","SwanBk E Mudgeeraba 805 275kV LINE","Swanbank E Ps","SwnBk D PS 113/11kV XFMR","SwnBk D PS113/11kV XFMR","SwnBk E PS 1 280/21kV XFMR","Sydenham 1 500kV BUS","Sydney East 330kV","Sydney North 330kV","T146_oakey Tangkam 7246 110kV LINE","Tailem_Bnd Keith 1 132kV LINE","Tamworth 330kV","Tangkam 2 110kV BUS","Tarong 1 275/132kV XFMR","Tarong 2 295/69kV XFMR","Tarong 275kV","Tarong Braemar 8814 275kV LINE","Tarong Braemar 8815 275kV LINE","Tarong Chinchilla 7168 132kV LINE","Tarong Middle Rdg 831 275kV LINE","Tarong Ps 3 300/21kV XFMR","Tarong Tarong Ps 601 66kV LINE","Tarong Tarong Ps 843 275kV LINE","Tarong Tarong Ps 844 275kV LINE","Tea Tree Gully 66kV","Templers 132kV","Templestow 1 220kV BUS","Templestow 1 220kV CAP","Templestow 2 220kV BUS","Templestow 2 66kV BUS","Templestow 4 66kV BUS","Tennyson (T142) 110kV","Tennyson 1 33kV BUS","Tennyson 2 33kV BUS","Terang 220kV","Terang 66kV CAP","Thebarton 66kV","Thomastown 1 220kV BUS","Thomastown 2 66kV BUS","Thomastown 2 66kV CAP","Thomastown 220kV","Thomastown 3 220kV CAP","Thomastown 4 66kV BUS","Thomastown 4B 66kV CAP","Tomago 132kV","Tomago 330kV","Torrens B Ps 275kV","Torrens North","Townsville Garbutt 7240 132kV LINE","Townsville Gt Ps","Townsville South 132kV","Townsville Twnsvl  PS 7241 132kV LINE","Townsvll S 2 132/69kV XFMR","Toyota 66kV","Trrns_A_PS Kilburn 66kV LINE","Trrns_A_PS Kilburn66kV LINE","Trrns_A_PS Magill 275kV LINE","Trrns_A_PS Magill275kV LINE","Tuggerah 330kV","Tumut 132kV","Turkinje 1 132/66kV XFMR","Turkinje 132kV","Tyabb 2 220kV BUS","Tyabb 220kV","Upper Tumut","Upr Kedron 1 110kV BUS","Uraidl 66kV","Vales Point 330kV","Victori Pk 5 110/33kV XFMR","Victoria Park 110kV","Vineyard 330kV","W Darra 4 110kV BUS","W Darra D 110kV BUS","W Darra Richlands 707 110kV LINE","W Darra SwanBk A 718 110kV LINE","W End 3 110/11kV XFMR","W Kiewa PS 2 11kV BUS","W Melbourn 1 22kV BUS","W Melbourn 1ext 220kV BUS","W Melbourn 3 22kV BUS","W Melbourn 3 66kV CAP","W Melbourn 4 220kV BUS","Wagga 132kV","Wallerawang Ps 330kV","Wangaratta 66kV","Wangaratta 66kV BUS","Waterloo 132kV","Wellington 330kV","Wellington/piper/orange 132kV Tee","West End 110kV","West Melbourne 220kV","Whyalla City","Winchelsea 66kV BUS","Wodonga 1 330kV BUS","Wodonga 1 66kV BUS","Wodonga 2 66kV BUS","Woolooga 2 275/132kV XFMR","Woolooga Gympie 747/2 132kV LINE","Woomera 132kV","Woree Cairns 7226 132kV LINE","Woree Cairns 7227 132kV LINE","Wudinna 66kV","Wurdong 275kV","Yadnarie 132kV","Yadnarie Wudinna 132kV LINE","Yadnarie Wudinna132kV LINE","Yallourn  Ps 220kV","Yallrn  PS 1 220kV BUS","Yarranlea 110kV"]},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed.","examples":["2000/01/01 00:00:10.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"VALIDTO":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date that this record applies until (exclusive)","examples":["2003/06/04 14:57:33.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"VOLTAGE":{"sql_type":"VARCHAR(20)","pl_type":"str","mandatory":false,"comment":"The voltage in KV for this equipment.\nTransformers may have multiple voltages defined.\nE.g. 132_110_33","examples":["6.6","11","138.6_11.6","288_138_19.1","288_138_19"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_EQUIPMENTDETAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":719557,"decompressed_size_all_time":177463900},"visibility":"Public","trigger":"When equipment details are added or changed"},"NETWORK_OUTAGECONSTRAINTSET":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGECONSTRAINTSET","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#9"],"comment":"NETWORK_OUTAGECONSTRAINTSET lists the Constraint Set or Sets that are expected to be invoked for the outage once it is confirmed to proceed.","primary_keys":["GENCONSETID","OUTAGEID"],"columns":{"GENCONSETID":{"sql_type":"VARCHAR(50)","pl_type":"str","mandatory":true,"comment":"ID for the constraint set","examples":["CA_BRIS_562B3098","CA_SYDS_55E0E615","F-I_ML_APD","F-I_ML_APD_LOAD","F-I_WDS","F-N_GUTHEGA_ZERO","F-Q_OAKEY1_ZERO","F-S_BARKIPS_ZERO","F-S_OSBGT_ZERO","F-S_TIBAT-G_ZERO","F-S_TIBAT-L_ZERO","F-T-CSGO","F-T-GO_CB_A752","F-T_GORDON_ZERO","I-6F_NS_050","I-6F_SN_050","I-BDBU_ONE","I-BL_ZERO","I-BURC","I-BURC_X1","I-BURC_X9","I-CTRL_ISSUE_TE","I-HYSE","I-MURRAYLINK","I-MUTE_757","I-MUTE_758","I-SVML_030","I-TE_ZERO","I-VS+LKB_050","I-VSML_030","I-VS_050","N-ARCH_96C","N-ARDM_8C","N-ARGI_96T","N-ARKS_965","N-ARSR_8E","N-ARTW_86","N-ARUL_8U","N-AR_TX","N-AVMA_17","N-AVMN_16","N-BABU","N-BADP","N-BANCO_999","N-BANYS_9GL","N-BECRD_94M","N-BHBESS_ZERO_INV","N-BROKENH1_ZERO","N-BROKENH1_ZERO_INV","N-BU-SCON1","N-BU-SCON2-3","N-BWRG_31","N-BYCR_61_15M","N-BYSW_39_15M","N-CHLS_89","N-CNLT_07","N-CNQN_976/977","N-CNSD_3C","N-COFB_998","N-CRGR_3H","N-CROOKWF2_ZERO","N-CRWF1_ZERO","N-CTMN_4_WG_CLOSE","N-CTYS_3L_WG_CLOSE","N-DEFI_9R3_C","N-DLETS_OS","N-DMSR_8J","N-DM_SVC","N-DPGF-99K-C","N-DPWG_63","N-DPWG_63_X5","N-DPYC-99D-C","N-DTKV_18_WG_CLOSE","N-DTSS_11","N-DTTX","N-ERVP_24","N-GG_ZERO","N-GNNDHSF1_ZERO_INV","N-GOONSF1_ZERO","N-GOONSF1_ZERO_INV","N-IGSS_78","N-JNWG_RADIAL","N-KCSN_14","N-KSRL","N-KVCW_3W_WG_CLOSE","N-LDMU_83","N-LDNC_81","N-LDTW_84","N-LIMOSF11_ZERO_INV","N-LSDU_9U6","N-LSLS_9U8","N-LSTN_96L","N-LS_VC1","N-LTWG_RADIAL","N-MBTE_1","N-MNYS_5_WG_CLOSE","N-MORBOR","N-MORIV","N-MPTX_94Y","N-MUTW_88","N-NIL_RBKU_CLOSED","N-QBYN_BESS_BDU_ZERO","N-SSWW_76","N-STWF1_ZERO","N-STWF1_ZERO_WT","N-SUNRSF1_ZERO","N-SUNRSF1_ZERO_INV","N-TWUL_85","N-TW_330_BUS1","N-TW_SVC","N-URNA_99F_C","N-WAGGA_330_BUSA","N-WAGGA_330_BUSB","N-WELLSF1_ZERO","N-WGNA_994_C","N-WGN_132BUS_1","N-WG_CB4102","N-WLON_947","N-WLTX","N-WLWO_79","N-WL_132BUS_B","N-WNMR_991","N-WRWSF1_ZERO_INV_WT","N-X_24+38","N-X_8C+DM+TW_SVC","N-X_8J+DM+TW_SVC","N-X_8U+DM+TW_SVC","N-X_947+949","N-X_966+KK+CH_CB892A","N-X_96T+9UG+9U2","N-X_9U6_9G2","N-X_9U6_9U7","N-X_ARKK_CH_CB892A","N-X_AVMA_SSWW","N-X_BWRG31+ERTX","N-X_MBTE_2","N-X_MBTE_3","N-X_TWNR_MORNR","N-X_TW_330_BUS3-5","NSA-N_BHB1","NSA-Q_GSTONE34_150","NSA-Q_GSTONE34_200","NSA-Q_GSTONE34_250","Q-810_PARALLEL_OPEN","Q-B2PSBRA_8841","Q-BCG_0","Q-BRHA","Q-BSLV","Q-BSNE","Q-BS_275BUS_CB","Q-CLARESF1_ZERO","Q-CLCAC_853","Q-CLCAC_854","Q-CLWU","Q-CL_275BUS_CB","Q-COLTX","Q-DW_RAMP_ZERO","Q-FNQ_822_REDUCE","Q-GB_VC","Q-GMGCH","Q-H11NE_SVC","Q-H13RS_SVC","Q-H35STM_SVC","Q-HACL","Q-KACH_7191","Q-KA_1TX","Q-KEP-HYB_27MW","Q-KMBG_7143","Q-KMBG_7184","Q-LCCP_8859","Q-LVDS","Q-LV_275_BUS_TX","Q-MARYRSF1_10MW","Q-MRGB_8848_8849","Q-MRTA_732","Q-NESTM","Q-NESTM_822_REDUCE","Q-NE_275BUS_CB","Q-NIL_822_REDUCE","Q-RGBYRSF1_ZERO","Q-RGLC_8875","Q-RLSP_809","Q-RSGMG","Q-RSWR","Q-RS_275BUS_CB","Q-SB_SEMI_ZERO","Q-SMCK","Q-SMRS","Q-SMSPL","Q-SM_275BUS_CB","Q-SP_VC","Q-STBS","Q-STBS_SIPS_OUT","Q-STR_CLRKCWF1_05","Q-STSTN_862","Q-ST_275BUS_CB","Q-TRME","Q-TUMMR_9907_9908","Q-TUSTX","Q-WDCG_8904","Q-WDHA_8867","Q-WOCY","Q-WO_VC","Q-WRTX","Q-WRWK","Q-WR_VC","Q-WS8904_0750","Q-WUBI","Q-X_BC_275_FNQ","Q-X_BKGO+GOBM_GOTX","Q-X_BSNE_NESM","Q-X_CLSTVS_TVRS","Q-X_HACL_HATR","Q-X_MRGB_MRGB","Q-X_NE_STM_SVC","Q-X_NQ_275_FDR3+BUS","Q-X_NQ_275_FDR_THREE","Q-X_RS_TX_TX_C","Q-X_RS_TX_TX_O","Q-YARANSF1_37MW","S-BC_CP","S-BG275KV_CB","S-BGRH","S-BGTX","S-BIPS_ZERO","S-BRBG","S-BRTW","S-BRTX3","S-BUPV2_0","S-CGMS","S-CGTI","S-CLPL","S-CLTX","S-CMWF_0","S-DC_CBG1","S-DC_CBG2","S-DC_CBG3","S-DLBAT-G_0","S-DLBAT-L_0","S-DLN_BUS","S-DVCL","S-DVTX","S-HVMG","S-LFPP_PELPT","S-LFTI_1","S-LGAPWF1_0","S-LGAPWF2_0","S-MANNSF2_0","S-MAPS2-PV_0","S-MAPS3-PV_0","S-MGTI","S-MWPS2-PV_0","S-MYTX1_44248OPEN","S-OSBNO1","S-PAPG","S-PA_CB6509","S-PA_VC1","S-PGPP","S-PLN_CB6210","S-PLTX1","S-PLTX2","S-POR_CB6215","S-PPPG_PELPT","S-PPT265","S-RBTU","S-RB_TX","S-SECB6611_10","S-SE_1CP","S-SE_CB6186_CB6187","S-SNOWNTH1_ZERO","S-SNOWSTH1_ZERO","S-STTX","S-TB1_TX","S-TB275_E_BUS","S-TB2_TX","S-TB3_TX","S-TB4_TX","S-TBCP1","S-TBSE","S-TBTU","S-TBTX4","S-TINO3","S-TITN1","S-TPRS","S-WE_MWP4","S-WP_0","S-WTTP","S-X_BC_CP","S-X_BGRH+BGCB","S-X_BGRH+BRTW","S-X_BGRH+DVTW","S-X_BGRH+RBTX","S-X_BRTW+TWPA","S-X_PA6510+BWPA","S-X_PA_VC_2","T-CESH","T-CSGO","T-CSLI","T-DGSH","T-FAJB","T-FARC2","T-FATI","T-GO23_250","T-GO_288","T-GO_BUS","T-GO_ZERO","T-GTHA","T-HAPM_220","T-LFTX","T-LIPM1_SLOAD_N-2","T-NIL_WCP_CLOSE","T-NWSD","T-X_FA_BUS_FASH","V-APHY_1","V-ARARAT_ZERO","V-ARCW","V-AR_WB_BA","V-BABE","V-BALL_BESS_BDU_ZERO","V-BRYBWF2_ZERO","V-BRYBWF_ZERO","V-DBUSS_L","V-DBUSS_T","V-DDMS","V-DDTX2_DBUSS_T","V-DDTX3","V-DDWO_RADIAL","V-DPMB","V-DUNDWF1_ZERO","V-DUNDWF2_ZERO","V-DUNDWF3_ZERO","V-ELAINEWF_ZERO","V-EPMB","V-EPTT","V-EP_BUS1","V-EP_BUS2","V-GLENSF_ZERO","V-GNSH","V-GNTS_BUS1_66","V-GPWF_ZERO","V-HBESS_G_ZERO","V-HBESS_L_ZERO","V-HGML","V-HGTR","V-HOTS_SVC","V-HWJL4_R","V-HWLY_1","V-HWLY_2","V-HWLY_3","V-HWRO12_R","V-HWRO3","V-HWSM","V-HWYP1","V-HYCP","V-HYTX_M12","V-HYTX_M3","V-JL_BUS2","V-KGTS_SVC","V-KGWT","V-KG_WE_RC","V-KIAMAL_SC_220CB","V-KMRC","V-KM_TX_220CB","V-KTSM_R","V-LAVNTH1_ZERO","V-LAVNTH2_ZERO","V-MLMO","V-MLTX_A1_R","V-MOPS_BUS2","V-MO_CB","V-MSSGG_TX","V-MTGELIBRAND_66","V-RCTS220CAPAUTO","V-RCTS_BUS2","V-ROSM","V-ROTT_R","V-ROYP5_R","V-ROYP6_R","V-ROYP78_R","V-SMSY","V-SMTX_F_R","V-SW_WF_70PCT","V-TRTS_BUS_CB_500","V-TSTT_R","V-VBB_BESS_BDU_ZERO","V-WETS_BTX","V-X_BESH_MLSY_NOEMTT","V-YP_BUS1"]},"OUTAGEID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"ID uniquely identifying the outage","examples":["909608","955504"],"is_integer":true,"num_int_bits":64},"ENDINTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The dispatch interval that this constraint applies until.","examples":["2024/05/28 16:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STARTINTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The dispatch interval that this constraint applies from","examples":["2024/04/03 06:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_OUTAGECONSTRAINTSET%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":281850,"decompressed_size_all_time":39431510},"visibility":"Public"},"NETWORK_OUTAGEDETAIL":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGEDETAIL","VERSION":3},{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGEDETAIL","VERSION":4}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#15"],"comment":"Lists asset owners planned outages for transmission equipment. This also includes details for transmission equipment that will not have an outage, but associated secondary equipment has an outage and a related constraint set may be invoked. This scenario is indicated by the ISSECONDARY field in the table","primary_keys":["ELEMENTID","EQUIPMENTID","EQUIPMENTTYPE","OUTAGEID","STARTTIME","SUBSTATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"ELEMENTID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Equipment element id","examples":["16","9483"],"is_integer":true,"num_int_bits":64},"EQUIPMENTID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"A unique identifier for this equipment at this substation, and based on its type","examples":["01","0602A","7136","110KV_751","110KV_787","110KV_F826","132KV_7109","132KV_7110/1","132KV_7119","132KV_7121","132KV_7122/1","132KV_7126/1","132KV_7131","132KV_7150/1","132KV_7153","132KV_7155","132KV_7165","132KV_7168","132KV_7183","132KV_7238","1ACAP_1B_66","1BB_3B_220","1BCAP_66","1B_2AB_220","1CAP","1CAP_1B","1CAP_22","1CSC","1H","1TH","1TR","1_BANK_H6","1_H10","1_H11","1_H5","1_T13","1_T59","222G","232M","275KV_842","275KV_877","2BCAP_66","2CSC","2H","2TR","2_H5","2_T81","3ACAP_66","3B_4B_220","3CAP_22","3H","3_T136","3_T81","4B2","4H","4_H22","5432A","5A1","5GN","5H","5MN","5MN2","622B","7MN1","7MN2","7MN3","7MN4","8C","91J","95C","99L","A1TR_220","A1TR_4B","A2TR_2B_220","A2TR_500","A2_1B_220","A4GTR_2B","A4TR_1B_500","AL10","AL11","APD_HYTS1_500","APD_HYTS2_500","ATS_4B_220","B2TR","B3TR","B4TR","B4TR_66","B5TR","B5TR_66","BATS_BETS_220","BATS_MLTS1_220","BATS_MLTS2_220","BATS_TGTS_220","BETS_SHTS_220","BLTS_1B","BLTS_2B","BS_4122","BTS_RTS_220","C2","C5","CAP_4B_66","CB6005","CB6021","CB6022","CB6025","CB6033","CB6068","CB6079","CB6084","CB6085","CB6093","CB6135","CB6140","CB6141","CB6148","CB6149","CB6157","CB6158","CB6161","CB6188","CB6523","CB6527","CB6561","CB6562","CB6633","CBTS4_LYPS3","CPLR_4012","CPLR_5022","CPLR_5032","CPLR_5042","CPLR_5052","CPLR_5062","C_61","C_62","DDTS1_1B","DDTS1_2B","DDTS1_SHTS1","DDTS2_1B","DDTS2_2B","DDTS_1B","DDTS_MSS1_330","DDTS_SHTS_220","DDTS_SMTS1_330","DDTS_SMTS2_330","DDTS_WOTS_330","DPS_MBTS_220","EPS_TTS_220","ERTS2_2B","FDR_7042","FDR_71192","FDR_71222","FDR_71872","FDR_71882_1","FDR_7642","FDR_7862","FDR_8062","FDR_8132","FDR_8162","FDR_8182","FDR_8652","FDR_8712","GNTS_SHTS3_220","GTS3_3B","GTS3_B4TR","H2TR","HOTS_RCTS_220","HWPS2_1B","HWPS_ROTS1_220","HWPS_ROTS2_220","HWTS3_2B","HWTS4_3B","HWTS4_4B","HYTS_SESS1_275","HYTS_SESS2_275","JIND_1B","KILNOF_1","LYPS3_4B","MA3MAN_T","MAGEAT_1","MINWAT_1","MLRC_RCTS_220","MLTS_SYTS1_500","MOPS2_2B","MSS1_2B","MTBCHG_1","MWTS2_1B","N/A","NB","NPSDVP_1","OSBTOA_3","PARPGW_1","PAR_22","PEWLAG_1","ROBMW4_2","ROBNWB_1","ROTS3_3B","ROTS5_1B","ROTS5_2B","ROTS_RWTS_220","ROTS_SVTS2_220","ROTS_YPS6_220","ROTS_YPS7_220","ROTS_YPS8_220","RWTS_4B","SB","SCTR","SMTS1_1B","SMTS1_2B","SVC1","SVC2","TABKEI_1","TABKEI_2","TF1","TF2","TF9","TFMR_4412","TFMR_4422","TFMR_6422","TINTOA_1","TOANOF_1","TTS2_WMTS2","T_1","T_2","T_3","T_WT","W","WATTEM_1","WB66","X2","X3","X5/3"]},"EQUIPMENTTYPE":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of equipment. Valid values are:\nLINE = Line\nTRANS = Transformer\nCB = Circuit breaker\nISOL = Isolator\nCAP = Capacitor\nREAC = Reactor\nUNIT = Unit","examples":["BUS","CAP","CB","LINE","N/A","REACT","SVC","TRANS"]},"OUTAGEID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":true,"comment":"ID uniquely identifying the outage","examples":["1002","25310"],"is_integer":true,"num_int_bits":64},"STARTTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The planned starting date and time of the outage","examples":["2002/10/31 10:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"The substation this equipment is located at","examples":["947TEE","ANG_CK","APD","ARMIDALE","AVON","BALRANLD","BATS","BAYSWATR","BETS","BLTS","BRINKW","BRKNHILL","BTS","BUNGAM","BURONGA","CANBERRA","CH_GDN","COLMBLLY","DAPTO","DAVENP","DDTS","DENILIQN","DPS","DUMARESQ","EPS","E_TCE","FBTS","GNTS","GTS","H10_BCMB","H11_NEBO","H13_ROSS","H15_LILY","H18_TRNG","H1_SBK_B","H22_LOGN","H2_SPINE","H32_CHLM","H39_WORE","H3_BELMT","H40_WURD","H5_WLGA","H6_GNGN","H7_GLAD","H9_PLMWD","HOTS","HUMMOC","HWPS","HWTS","HYTS","H_VALL","JINDERA","JLTS","KAR_H_PS","KEITH","KEMPSEY","KGTS","KILBUR","KINCRA","KTS","LADB_G","LYPS","MAGILL","MARULAN","MA_3","MBTS","MINTAR","MLRC","MLTS","MOBILO","MORP_E","MT_BAR","MT_PIPER","MUNMORAH","MURRAY","MW_4","N/A","NEWCSTLE","NORTHF","NPS","N_OSBN","N_W_B","OURIMBAH","PARA","PEAKHRST","PENO_W","PGWEST","PLAY","R2_BRAE","RCTS","ROTS","ROTS_500","RTS","RWTS","R_TOWN","SHTS","SMTS","SNUGGY","SSBBH","SSSPD","SVTS","SYD_EAST","SYD_STH","SYD_WEST","SYTS","S_EAST","T108_BNL","T111_NOR","T11_CBLT","T136_ABM","T137_NGY","T13_CHIN","T22_CALL","T26_BILO","T30_ASHW","T34_MRNB","T37_COLL","T38_MKAY","T39_PROS","T48_TLLY","T50_INFL","T55_TURK","T56_TV_S","T59_MRBO","T5_GLAD","T65_ALCK","T67_KMIS","T69_NLDS","T71_CLMT","T81_CADE","T93_CLS","TEMPLE","TGTS","TIPS_A","TI_N","TOMAGO","TRNG_PS","TTS","TUGGERAH","TUMUT1_2","T_BEND","VALES_PT","WAGGA132","WAGGA330","WELLNGTN","WOTS","W_LOO","YANCO","YASS","YPS"]},"ACTUAL_ENDTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The actual ending date/time of the outage","examples":["2003/04/28 09:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACTUAL_STARTTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The actual starting date/time of the outage","examples":["2002/10/31 14:19:00"],"parse_csv_as_string":true,"is_s_datetime":true},"COMPANYREFCODE":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The asset owners reference code for this outage","examples":["068","3 TX","2003213","3M","3m","AS365957","AS369320","AS371098","AS372339","CC","CC2003229","DGP","E360419","ESP","ESP1","HVS 220403","NOTE","Q02S/1880","Q02W/0423","Q02W/0424","Q03I/1718","Q03I/2070","Q03I/2082","Q03I/2119","Q03O/0383","Q03O/0458","Q03O/0485","Q03O/0486","Q03O/0487","Q03O/0488","Q03O/0499","Q03O/0528","Q03O/0565","Q03O/0579","Q03O/0580","Q03O/0581","Q03O/0615","Q03O/0619,621","Q03O/062","Q03O/0622,623","Q03O/0624","Q03O/0625","Q03O/0626","Q03O/0627","Q03O/0628","Q03O/0629","Q03O/0630","Q03O/0631","Q03O/0633","Q03O/0634","Q03O/0635","Q03O/0637","Q03O/0641A-D","Q03S/0109","Q03S/0138","Q03S/0199","Q03S/0207","Q03S/0384","Q03S/0507","Q03S/0516","Q03S/0579","Q03S/0587","Q03S/0599","Q03S/0600","Q03S/0601","Q03S/0602","Q03S/0603","Q03S/0604","Q03S/0688","Q03S/0690","Q03S/0696","Q03S/0729","Q03S/0733","Q03S/0755B","Q03S/0760","Q03S/0775","Q03S/0844","Q03S/0848","Q03S/0864","Q03S/0865","Q03S/0866","Q03S/0868","Q03S/0869","Q03S/0878","Q03S/0888","Q03S/0893","Q03S/0902","Q03S/0903","Q03S/0904","Q03S/0906","Q03S/0914","Q03S/0915","Q03S/0916","Q03S/0917","Q03S/0918","Q03S/0919","Q03S/0920","Q03S/0921","Q03S/0926","Q03S/0932","Q03S/0938","Q03S/238","Q03W/0104","Q03W/0116","Q03W/0129","Q03W/0173","R03S/0261","RB 9","REF 0148","REF 0149","SSP0003","SSP0004","SSP0005","SSP0006","SSP0007","SSP0008","SSP0009","SSP0019","SSP0022","SSP0030","SSP0031","SSP0032","SSP0033","SSP0045","SSP0046","SSP0050","SSP0058","SSP0059","SSP0060","SSP0074","SSP0075","SSP0076","SSP0077","SSP0078","SSP0082","SSP0088","SSP0089","SSP0090","SSP0091","SSP0094","SSP0100 PART A","SSP0100 PART B","SSP0110","SSP0125","SSP0126","SSP0127","SSP0128","SSP0129","SSP0130","SSP0131","SSP0132","SSP0133","SSP0134","SSP0135","SSP9506","SSP9507","SSP9723","SSP9869","SSP9870","SSP9959","T37/71222","cc","ea2","rk"]},"ENDTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The planned ending date and time of the outage","examples":["2003/04/28 17:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ISSECONDARY":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"1 = The outage is for a secondary piece of equipment that has an associated constraint set. The transmission equipment is still in service. 0 = The outage is for the transmission equipment","examples":["0","1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed","examples":["2003/04/29 14:46:34.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"OUTAGESTATUSCODE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":false,"comment":"A code representing the status of the outage.\nThe OUTAGESTATUSCODE table will store a detailed description of each code.","examples":["COMPLETE","UTP","WDRAWN"]},"REASON":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"The reason provided by the asset owner for this outage","examples":["HV equipt maintenance","Secondary equipt maintenance"]},"RECALLTIMEDAY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The recall time in minutes during the day","examples":["0","-1","5","34560"],"is_integer":true,"num_int_bits":64},"RECALLTIMENIGHT":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The recall time in minutes during the night","examples":["0","-1","5","34560"],"is_integer":true,"num_int_bits":64},"RESUBMITOUTAGEID":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The new outage id created from a resubmit.","examples":["1556","25310"],"is_integer":true,"num_int_bits":64},"RESUBMITREASON":{"sql_type":"VARCHAR(50)","pl_type":"str","mandatory":false,"comment":"Changes to an outage key details may require the outage to be resubmitted.\nA new outage id will then be allocated and the outage will be reassessed.\nThis field will detail the reason for the change.","examples":["Information Update","NEMMCO Request","Resource Problems","Weather"]},"SUBMITTEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this outage was first submitted","examples":["2003/04/29 12:04:46"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_OUTAGEDETAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":23791151,"decompressed_size_all_time":5714103760},"visibility":"Public"},"NETWORK_OUTAGESTATUSCODE":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"OUTAGESTATUSCODE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#23"],"comment":"NETWORK_OUTAGESTATUSCODE describes the different outage status codes","primary_keys":["OUTAGESTATUSCODE"],"columns":{"OUTAGESTATUSCODE":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":true,"comment":"A code representing the status of an outage","examples":["COMPLETE","INFO","MTLTP","PDLTP","PTP","PTR","RESUBMIT","STLTP","SUBMIT","UTP","WD REQ","WDRAWN"],"col_name_also_metadata":true},"DESCRIPTION":{"sql_type":"VARCHAR(100)","pl_type":"str","mandatory":false,"comment":"A description of the status code","examples":["Completed","Information","Medium term timeframe likely to proceed","Permission to Proceed","Permission to Restore","Predispatch timeframe likely to proceed","Resubmitted","Short term timeframe likely to proceed","Submitted","Unlikely to proceed","Withdraw Request","Withdrawn"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed","examples":["2012/04/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_OUTAGESTATUSCODE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":595,"decompressed_size_all_time":154350},"visibility":"Public","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns OUTAGESTATUSCODE. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}]},"NETWORK_RATING":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"RATING","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#29"],"comment":"NETWORK_RATING defines a list of the equipment ratings that may be used as inputs to market constraints.\nIf the rating is flagged as dynamic then in real-time the rating will be dynamically determined and the static value will be used as a fallback value should the dynamic value fail.\nNote:\nIn some rare cases equipment has ratings provided from more than one TNSP. This is identified by a different SPD Id. The value used in the NEM is normally the more restrictive of the two values.","primary_keys":["SPD_ID","VALIDFROM"],"indexes":[["LASTCHANGED"]],"columns":{"SPD_ID":{"sql_type":"VARCHAR(21)","pl_type":"str","mandatory":true,"comment":"ID defining this data source for use in constraints","examples":["NRAT15_ARKS965","NRAT15_CNCW6","NRAT15_CWCN6","NRAT15_CWKV3W","NRAT15_DTKV18","NRAT15_ERNC93","NRAT15_JNWO060","NRAT15_KCSS13","NRAT15_KVCW3W","NRAT15_KVDT18","NRAT15_LDMU83","NRAT15_LDTW84","NRAT15_LTCN07","NRAT15_LTMS","NRAT15_LTUT","NRAT15_LTYS03","NRAT15_MNYS4","NRAT15_MNYS5","NRAT15_MUTW88","NRAT15_SWBY39","NRAT15_TLDT983","NRAT15_TWAR86","NRAT15_UTCN01","NRAT15_UTLT","NRAT15_UTMS","NRAT15_UTYS02","NRAT15_YSBY61","NRAT15_YSMN4","NRAT15_YSMN5","NRAT15_YSUT02","NRAT2H_AR_TX3","NRAT2H_AR_TX6","NRAT2H_BW_TX1","NRAT2H_BW_TX2","NRAT2H_MP_TX1","NRAT2H_MP_TX2","NRAT2H_WG_TX3","NRAT30_DP_TX3","NRAT30_DP_TX4","NRAT30_LTMS","NRAT30_LTUT","NRAT30_UTLT","NRAT30_UTMS","NRATCN_ARKS965","NRATCN_AVMA17","NRATCN_BWLD33","NRATCN_BWMP5A3","NRATCN_BWWO5A4","NRATCN_BW_TX1","NRATCN_BW_TX2","NRATCN_BYMN35","NRATCN_BYMN36","NRATCN_BYYS61","NRATCN_CHRL9W3","NRATCN_CNCW6","NRATCN_CNUT01","NRATCN_DP_TX3","NRATCN_DP_TX4","NRATCN_DTSS11","NRATCN_ERNC90","NRATCN_ERNC93","NRATCN_ERVP24","NRATCN_JNWO060","NRATCN_KCMA37","NRATCN_KVDT18","NRATCN_LDBW33","NRATCN_LDNC81","NRATCN_LDTM82","NRATCN_LDTW84","NRATCN_LSLS_9U8_NEG","NRATCN_LSLS_9U9_NEG","NRATCN_LSLS_9W1_NEG","NRATCN_LTCN07","NRATCN_LTMS","NRATCN_LTUT","NRATCN_LTWG051","NRATCN_LTYS03","NRATCN_MNAV16","NRATCN_MNDT8","NRATCN_MNYS5","NRATCN_MPBW5A3","NRATCN_MPMN35","NRATCN_MPWW71","NRATCN_MP_TX1","NRATCN_MP_TX2","NRATCN_SSDT11","NRATCN_SWBY39","NRATCN_TLDT983","NRATCN_TLDT984","NRATCN_TLDT987","NRATCN_TWAR86","NRATCN_URYC99F","NRATCN_UTCN01","NRATCN_UTLT","NRATCN_UTMS","NRATCN_UTYS02","NRATCN_VPER24","NRATCN_VPMM23","NRATCN_WGJN62","NRATCN_WGUR9R1","NRATCN_WGUR9R2","NRATCN_WG_TX3","NRATCN_WOJN060","NRATCN_WOJN060_NEG","NRATCN_WWIG77","NRATCN_WWMP71","NRATCN_WWSS76","NRATCN_YSBJ970","NRATCN_YSBY61","NRATCN_YSCN9","NRATCN_YSMN4","NRATCN_YSMN5","NRATCN_YSMR99M","NRATCN_YSUT02","NRATCN_YSWG990","NRATSE_ARCH96C","NRATSE_ARKK966","NRATSE_ARKS965","NRATSE_ARTW86","NRATSE_AVMA17","NRATSE_AVMN16","NRATSE_BABU_X5/3","NRATSE_BURC0X1","NRATSE_BWLD33","NRATSE_BWLD34","NRATSE_BWMP5A3","NRATSE_BWRG31","NRATSE_BWSW32","NRATSE_BWWO5A4","NRATSE_BYGR61","NRATSE_BYMN35","NRATSE_BYMN36","NRATSE_BYSW39","NRATSE_BYYS61","NRATSE_CHRL9W3","NRATSE_CNCW6","NRATSE_CNUT01","NRATSE_CNYS9","NRATSE_CWCN6","NRATSE_CWKV3W","NRATSE_DMBCK8L_NEG","NRATSE_DMBCK8M_NEG","NRATSE_DPBA_X5/1","NRATSE_DP_TX3","NRATSE_DP_TX4","NRATSE_DTKV18","NRATSE_DTMN8","NRATSE_DTSS11","NRATSE_ERNC90","NRATSE_ERNC93","NRATSE_ERVP24","NRATSE_IGSS78","NRATSE_JNWG62","NRATSE_JNWO060","NRATSE_KCMA37","NRATSE_KCSN14","NRATSE_KCSS13","NRATSE_KVCW3W","NRATSE_KVDT18","NRATSE_LDBW33","NRATSE_LDMU83","NRATSE_LDNC81","NRATSE_LDTM82","NRATSE_LDTW84","NRATSE_LSLS9U8","NRATSE_LSLS9U9","NRATSE_LSLS9W1","NRATSE_LSLS_9U8","NRATSE_LSLS_9U8_NEG","NRATSE_LSLS_9U9","NRATSE_LSLS_9U9_NEG","NRATSE_LSLS_9W1","NRATSE_LSLS_9W1_NEG","NRATSE_LTCN07","NRATSE_LTWG051","NRATSE_LTYS03","NRATSE_MMTG2M","NRATSE_MMVP23","NRATSE_MNAV16","NRATSE_MNBY35","NRATSE_MNBY36","NRATSE_MNDT8","NRATSE_MNYS4","NRATSE_MNYS5","NRATSE_MPBW5A3","NRATSE_MPBY5A6","NRATSE_MPBY5A7","NRATSE_MPMP94Y","NRATSE_MPWW70","NRATSE_MPWW71","NRATSE_MUTW88","NRATSE_NBMV9W6","NRATSE_NCTM94","NRATSE_NCVP92","NRATSE_RCBU0X1_NEG","NRATSE_RLKS9W2","NRATSE_SSBC41","NRATSE_SSDT11","NRATSE_SSLP12","NRATSE_SWBY39","NRATSE_SWLP30","NRATSE_TGSN21","NRATSE_TGTA963","NRATSE_TLDT983","NRATSE_TLDT984","NRATSE_TLDT987","NRATSE_TMNC94","NRATSE_TWAR85","NRATSE_TWAR86","NRATSE_URFL99A","NRATSE_URYC99F","NRATSE_UTCN01","NRATSE_UTYS02","NRATSE_VPER24","NRATSE_VPMM23","NRATSE_VPNC92","NRATSE_VPSN22","NRATSE_WGAN996","NRATSE_WGJN62","NRATSE_WGLT051","NRATSE_WGUR9R1","NRATSE_WGUR9R2","NRATSE_WGYC994","NRATSE_WLPK94K","NRATSE_WOBW5A4","NRATSE_WOJN060","NRATSE_WOJN060_NEG","NRATSE_WOMP5A5","NRATSE_WOWL79","NRATSE_WWIG77","NRATSE_WWMP71","NRATSE_WWSS76","NRATSE_YSBJ970","NRATSE_YSBY61","NRATSE_YSCN9","NRATSE_YSGR3J","NRATSE_YSLT03","NRATSE_YSMN4","NRATSE_YSMN5","NRATSE_YSMR99M","NRATSE_YSUT02","NRATSE_YSWG990","NRATSE_YS_TX1","QRATCN_CLBCN7349","QRATCN_CLBCN7350","QRATCN_CLWU871","QRATCN_CNTR7168","QRATCN_CNTR7183","QRATCN_CVKCK7128/1","QRATCN_CWTU7389","QRATCN_GOWE791","QRATCN_MDSPTF907","QRATCN_MEAB8823","QRATCN_MMMR9907","QRATCN_MRTR831","QRATCN_MR_TX5","QRATCN_MUTE757","QRATCN_MUTE758","QRATCN_MU_TX1","QRATCN_MU_TX2","QRATCN_MU_TX3","QRATCN_NESTM8845","QRATCN_RLRI710","QRATCN_RSTVS7249","QRATCN_SEGO8826","QRATCN_SPCE745/1","QRATCN_SPCE746/1","QRATCN_TAMR731","QRATCN_TAMR732","QRATCN_TRCN7168","QRATCN_TRCN7183","QRATCN_TR_TX1","QRATCN_TR_TX4","QRATCN_TVAS7276","QRATCN_TVYS7325","QRATCN_UKWE776","QRATCN_WEUK776","QRATEM_CLBCN7349","QRATEM_CLBCN7350","QRATEM_CNTR7168","QRATEM_CNTR7183","QRATEM_CVKCK7128/1","QRATEM_CWTU7389","QRATEM_GOWE791","QRATEM_MDSPTF907","QRATEM_MEAB8823","QRATEM_MMMR9907","QRATEM_MR_TX5","QRATEM_NESTM8845","QRATEM_RLRI710","QRATEM_RSTVS7249","QRATEM_SEGO8826","QRATEM_SPCE745/1","QRATEM_SPCE746/1","QRATEM_TRCN7168","QRATEM_TRCN7183","QRATEM_TR_TX1","QRATEM_TR_TX4","QRATEM_TVYS7325","QRATEM_UKWE776","QRATEM_WEUK776","QRATSE_BCKDM8L","QRATSE_BCKDM8M","QRATSE_BKSB8819","SRAT15_HUWT","SRAT15_KESN1","SRAT15_WTTP","SRATCN_ACMP3","SRATCN_BE_TX1","SRATCN_BE_TX2","SRATCN_BGDV","SRATCN_BGPA","SRATCN_BGRH","SRATCN_BGST","SRATCN_BLMTG1","SRATCN_BLSN1","SRATCN_BRDV","SRATCN_BRRH","SRATCN_CDKB","SRATCN_CHTI","SRATCN_CHTX1","SRATCN_CLMD","SRATCN_CLTX1","SRATCN_DVBG","SRATCN_DVTX2","SRATCN_HUST","SRATCN_KBTX5","SRATCN_KESN1","SRATCN_KETB1","SRATCN_KETB2","SRATCN_KHKN","SRATCN_MAMP2","SRATCN_MGTI","SRATCN_MHNW1","SRATCN_MHNW2","SRATCN_MH_TX4","SRATCN_MKRB","SRATCN_MW4WE","SRATCN_MWP3RB","SRATCN_MYSESGT","SRATCN_MY_TX1","SRATCN_MY_TX2","SRATCN_NWB_TX1","SRATCN_NWB_TX3","SRATCN_NWRB","SRATCN_PANAP","SRATCN_PARS","SRATCN_PLYD1","SRATCN_ROBT_TX1","SRATCN_ROBT_TX2","SRATCN_SEHY1","SRATCN_SEHY2","SRATCN_SESGMYT","SRATCN_STST-T","SRATCN_TBCG1","SRATCN_TBMO1","SRATCN_TBTU1","SRATCN_TINO3","SRATCN_TPRS","SRATCN_WCCL1","SRATCN_WCCL2","SRATCN_WHYD1","SRATCN_WTTP","SRATCN_WYCL","SRATCN_YDMD","SRATEM_BE_TX1","SRATEM_BE_TX2","SRATEM_BGDV","SRATEM_BGPA","SRATEM_BGRH","SRATEM_BGST","SRATEM_BRRH","SRATEM_CDKB","SRATEM_CLDV","SRATEM_CLTX1","SRATEM_CLWYT","SRATEM_CNDV","SRATEM_CNRB","SRATEM_DVBG","SRATEM_DVBR","SRATEM_DVCN","SRATEM_DVPF","SRATEM_DVRB2","SRATEM_DVTX2","SRATEM_HUST","SRATEM_HUWT","SRATEM_HVME","SRATEM_KBNF","SRATEM_KBTX5","SRATEM_KESN1","SRATEM_KETB1","SRATEM_KETB2","SRATEM_KHKN","SRATEM_KNKH","SRATEM_KNPW","SRATEM_LFTI","SRATEM_MAMP2","SRATEM_MGHV","SRATEM_MGPA","SRATEM_MGTI","SRATEM_MHBE1","SRATEM_MHNW1","SRATEM_MHNW2","SRATEM_MH_TX4","SRATEM_MKRB","SRATEM_MNWT","SRATEM_MOTB1","SRATEM_MTBL","SRATEM_MW4WE","SRATEM_MWP1NW","SRATEM_MWP3RB","SRATEM_MYSESGT","SRATEM_NOTI_3","SRATEM_NOTI_4","SRATEM_NWMH1","SRATEM_NWMH2","SRATEM_NWMWP1","SRATEM_NWRB","SRATEM_PAAC","SRATEM_PAMG","SRATEM_PANAP","SRATEM_PAPG","SRATEM_PARS","SRATEM_PATI","SRATEM_PGWPPT","SRATEM_PLYD1","SRATEM_PPLF","SRATEM_PPPG","SRATEM_PWKN","SRATEM_PWSE","SRATEM_RBMW3","SRATEM_RBMW4","SRATEM_RBNW","SRATEM_ROBT_TX1","SRATEM_ROBT_TX2","SRATEM_SEHY1","SRATEM_SEHY2","SRATEM_SEMT","SRATEM_SESGMYT","SRATEM_SETB1","SRATEM_SETB2","SRATEM_SNBL","SRATEM_SNKH","SRATEM_TBCG1","SRATEM_TBMO1","SRATEM_TBTU1","SRATEM_TICG","SRATEM_TIKB","SRATEM_TIMG","SRATEM_TINF","SRATEM_TIPA","SRATEM_TPWT","SRATEM_WHYD1","SRATEM_WTTP","SRATEM_WYCL","SRATEM_YDPL1","SRATEM_YDWY","SRATSE_SN_TX2","SRATSE_SN_TX4","SRATSH_ACMP3","SRATSH_BE_TX1","SRATSH_BE_TX2","SRATSH_BGDV","SRATSH_BGPA","SRATSH_BGRH","SRATSH_BGST","SRATSH_BLSN1","SRATSH_BRRH","SRATSH_CDKB","SRATSH_CHTX1","SRATSH_CLMD","SRATSH_CLTX1","SRATSH_DVBG","SRATSH_DVTX2","SRATSH_HUWT","SRATSH_KBTX5","SRATSH_KESN1","SRATSH_KETB1","SRATSH_KETB2","SRATSH_KNPW","SRATSH_MAMP2","SRATSH_MHNW1","SRATSH_MHNW2","SRATSH_MH_TX4","SRATSH_MNWT","SRATSH_MOTB1","SRATSH_MTBL","SRATSH_MW4WE","SRATSH_MYSESGT","SRATSH_NOTI_3","SRATSH_NOTI_4","SRATSH_NWMH1","SRATSH_NWMH2","SRATSH_NWRB1","SRATSH_PAAC","SRATSH_PANAP","SRATSH_PARS","SRATSH_PWKN","SRATSH_PWSE","SRATSH_RBMW3","SRATSH_RBNW1","SRATSH_ROBT_TX1","SRATSH_ROBT_TX2","SRATSH_SESGMYT","SRATSH_SETB1","SRATSH_SETB2","SRATSH_SNBL","SRATSH_SNKH","SRATSH_TBCG1","SRATSH_TBTU1","SRATSH_WCCL1","SRATSH_WCCL2","SRATSH_WCDV","SRATSH_WCWY","SRATSH_WTTP","SRATSH_WYCL","SRATSH_YDMD","TRAT15_BUEB","TRAT15_BWLF","TRAT15_BWWA","TRAT15_CRNN","TRAT15_CSCL_T","TRAT15_CSCR1","TRAT15_CSCR2","TRAT15_CSLI2","TRAT15_CSNN","TRAT15_CSRI","TRAT15_GOCS1","TRAT15_GOCS2","TRAT15_GTHA1","TRAT15_GTHA2","TRAT15_GTSH1","TRAT15_GTSH2","TRAT15_HAGT1","TRAT15_HAGT2","TRAT15_HANW1","TRAT15_HANW2","TRAT15_HATR1","TRAT15_HMWT_T","TRAT15_LELE_T1","TRAT15_LFBW","TRAT15_LFRI1","TRAT15_LFRI2","TRAT15_LICL_T","TRAT15_LICS","TRAT15_MBNN","TRAT15_MBTA","TRAT15_NNCR","TRAT15_NNCS","TRAT15_NWHA1","TRAT15_NWHA2","TRAT15_PASH","TRAT15_PAUL","TRAT15_PMHA1","TRAT15_PMHA2","TRAT15_PMHA3","TRAT15_PMHA4","TRAT15_PMSH","TRAT15_PMWA","TRAT15_POPM5","TRAT15_SHBU1","TRAT15_SHBU2","TRAT15_SHFA1","TRAT15_SHFA2","TRAT15_SHGT1","TRAT15_SHGT2","TRAT15_SHPA","TRAT15_SHPM","TRAT15_TAMB","TRAT15_TANN1","TRAT15_TANN2","TRAT15_TRHA1","TRAT15_TRHA2","TRAT15_TULE_T1","TRAT15_TULE_T2","TRAT15_TUTA1","TRAT15_TUTA2","TRAT15_ULEB","TRAT15_ULPA","TRAT15_WABW","TRAT15_WALE_T1","TRAT15_WALE_T2","TRAT15_WAPM","TRAT4H_BU_TX2","TRAT4H_CS_TX1","TRAT4H_CS_TX2","TRAT4H_CS_TX3","TRAT4H_CS_TX4","TRAT4H_GT_TX1","TRAT4H_GT_TX2","TRAT4H_GT_TX3","TRAT4H_PMTX","TRAT4H_SH_TX1","TRAT4H_SH_TX2","TRATCN_BBGT1","TRATCN_BBGT2","TRATCN_BUEB","TRATCN_BUHM","TRATCN_BUPL","TRATCN_BU_TX2","TRATCN_BWLF","TRATCN_BWWA","TRATCN_CAWY","TRATCN_CLT_CS","TRATCN_CRNN","TRATCN_CRT_RI","TRATCN_CSCL_T","TRATCN_CSCR1","TRATCN_CSCR2","TRATCN_CSCR_T","TRATCN_CSLI2","TRATCN_CSNN","TRATCN_CSRI","TRATCN_CS_TX1","TRATCN_CS_TX2","TRATCN_CS_TX3","TRATCN_CS_TX4","TRATCN_DESD_T","TRATCN_FAJB","TRATCN_FASH1","TRATCN_FASH2","TRATCN_FA_TX1","TRATCN_FA_TX2","TRATCN_GOCS1","TRATCN_GOCS2","TRATCN_GTHA1","TRATCN_GTHA2","TRATCN_GTSH1","TRATCN_GTSH2","TRATCN_GT_TX1","TRATCN_GT_TX2","TRATCN_GT_TX3","TRATCN_HAGT1","TRATCN_HAGT2","TRATCN_HANW1","TRATCN_HANW2","TRATCN_HAPM1","TRATCN_HAPM2","TRATCN_HAPM3","TRATCN_HAPM4","TRATCN_HATR1","TRATCN_HATR2","TRATCN_HA_TX1","TRATCN_HA_TX2","TRATCN_HMWT_T","TRATCN_LELE_T1","TRATCN_LFBW","TRATCN_LFRI1","TRATCN_LFRI2","TRATCN_MBNN","TRATCN_MBTA","TRATCN_NNCR","TRATCN_NNCS","TRATCN_NNMB","TRATCN_NNTA1","TRATCN_NNTA2","TRATCN_NWHA1","TRATCN_NWHA2","TRATCN_PASH","TRATCN_PAUL","TRATCN_PMHA1","TRATCN_PMHA2","TRATCN_PMHA3","TRATCN_PMHA4","TRATCN_PMSH","TRATCN_PMTX","TRATCN_PMWA","TRATCN_RILF1","TRATCN_RILF2","TRATCN_SHBU1","TRATCN_SHBU2","TRATCN_SHFA1","TRATCN_SHFA2","TRATCN_SHGT1","TRATCN_SHGT2","TRATCN_SHPA","TRATCN_SHPM","TRATCN_SH_TX1","TRATCN_SH_TX2","TRATCN_TAMB","TRATCN_TANN1","TRATCN_TANN2","TRATCN_TATU1","TRATCN_TATU2","TRATCN_TRHA1","TRATCN_TRHA2","TRATCN_TULE_T1","TRATCN_TULE_T2","TRATCN_TUTA1","TRATCN_TUTA2","TRATCN_ULEB","TRATCN_ULPA","TRATCN_WABW","TRATCN_WALE_T1","TRATCN_WALE_T2","TRATCN_WAPM","VRAT15_ARBR","VRAT15_ARST","VRAT15_BABE","VRAT15_BAML1","VRAT15_BAML2","VRAT15_BANBR","VRAT15_BAWB","VRAT15_BEBA","VRAT15_BEKG","VRAT15_BESH","VRAT15_BLFB","VRAT15_BLNP","VRAT15_BRAR","VRAT15_BRBAN","VRAT15_BTTT1","VRAT15_BTTT3","VRAT15_DDMS1","VRAT15_DDMS2","VRAT15_DDSM1","VRAT15_DDWO","VRAT15_FBBL","VRAT15_FBNP","VRAT15_FBWM1","VRAT15_FBWM2","VRAT15_GNDD1","VRAT15_GNDD3","VRAT15_GTKT1","VRAT15_GTKT2","VRAT15_GTKT3","VRAT15_GTML1","VRAT15_GTML2","VRAT15_GTPTH1","VRAT15_GTPTH2","VRAT15_HOWB","VRAT15_HWCB4","VRAT15_HWJL1","VRAT15_HWJL2","VRAT15_HWJL3","VRAT15_HWJL4","VRAT15_HWMWT","VRAT15_HWSM1","VRAT15_JLHW1","VRAT15_JLHW2","VRAT15_JLHW3","VRAT15_JLHW4","VRAT15_KGBE","VRAT15_KTAT","VRAT15_KTBL","VRAT15_KTSM","VRAT15_KTSY","VRAT15_KTTT1","VRAT15_KTTT2","VRAT15_MBDD1","VRAT15_MBDD2","VRAT15_MLSY1","VRAT15_MLSY2","VRAT15_MLTG","VRAT15_MSDD1","VRAT15_MSDD2","VRAT15_MSLT","VRAT15_MSUT","VRAT15_NPBL","VRAT15_NPFB","VRAT15_RORT1","VRAT15_RORT4","VRAT15_RORW","VRAT15_ROTS","VRAT15_ROTT","VRAT15_RTBT","VRAT15_RTRO1","VRAT15_RTRO4","VRAT15_RWRO","VRAT15_RWTT","VRAT15_SHDD","VRAT15_SHGN1","VRAT15_SHGN3","VRAT15_SMDD1","VRAT15_SMRO3","VRAT15_SMTT1","VRAT15_SMTT2","VRAT15_SM_TX_F2","VRAT15_STAR","VRAT15_SYSM1","VRAT15_SYSM2","VRAT15_TGML","VRAT15_TSRO","VRAT15_TSTT","VRAT15_TTBT1","VRAT15_TTBT3","VRAT15_TTEP","VRAT15_TTKT1","VRAT15_TTKT2","VRAT15_TTRO","VRAT15_TTRW","VRAT15_TTSM1","VRAT15_TTSM2","VRAT15_TTTS","VRAT15_WBBA","VRAT15_WBHO","VRAT15_WMFB1","VRAT15_WMFB2","VRAT15_WMKT1","VRAT15_WMKT2","VRAT15_YPRO8","VRAT20_DD_TX_H1","VRAT20_DD_TX_H2","VRAT20_DD_TX_H3","VRAT2H_ML_TX_A2","VRAT30_HYSE1","VRAT30_HYSE2","VRAT30_MSLT","VRAT30_MSUT","VRATCN_ARBR","VRATCN_ARST","VRATCN_ATBL","VRATCN_ATKT","VRATCN_BABE","VRATCN_BAML1","VRATCN_BAML2","VRATCN_BANBR","VRATCN_BATG","VRATCN_BAWB","VRATCN_BEBA","VRATCN_BEKG","VRATCN_BESH","VRATCN_BLAT","VRATCN_BLFB","VRATCN_BLKT","VRATCN_BLNP","VRATCN_BRAR","VRATCN_BRBAN","VRATCN_BTRT","VRATCN_BTTT1","VRATCN_BTTT3","VRATCN_CBHW4","VRATCN_CBRO4","VRATCN_CB_TX_A1","VRATCN_DDGN1","VRATCN_DDGN3","VRATCN_DDMB1","VRATCN_DDMS1","VRATCN_DDMS2","VRATCN_DDSH","VRATCN_DDSM1","VRATCN_DDSM2","VRATCN_DDWO","VRATCN_DD_TX_H1","VRATCN_DD_TX_H2","VRATCN_DD_TX_H3","VRATCN_EPMB1","VRATCN_EPMB2","VRATCN_EPTT","VRATCN_FBBL","VRATCN_FBNP","VRATCN_FBWM1","VRATCN_FBWM2","VRATCN_GNDD1","VRATCN_GNDD3","VRATCN_GNSH1","VRATCN_GNSH3","VRATCN_GTKT1","VRATCN_GTKT2","VRATCN_GTKT3","VRATCN_GTML1","VRATCN_GTML2","VRATCN_GTPTH1","VRATCN_GTPTH2","VRATCN_HORC","VRATCN_HOWB","VRATCN_HWCB4","VRATCN_HWJL1","VRATCN_HWJL2","VRATCN_HWJL3","VRATCN_HWJL4","VRATCN_HWMWT","VRATCN_HWRO1","VRATCN_HWRO2","VRATCN_HWRO3","VRATCN_HWSM1","VRATCN_HWSM2","VRATCN_HWYP1","VRATCN_HWYP2","VRATCN_HW_TX_A1","VRATCN_HW_TX_A2","VRATCN_HW_TX_A3","VRATCN_HW_TX_A4","VRATCN_HYSE1","VRATCN_HYSE2","VRATCN_HY_TX_M1","VRATCN_HY_TX_M2","VRATCN_JLHW1","VRATCN_JLHW2","VRATCN_JLHW3","VRATCN_JLHW4","VRATCN_KGBE","VRATCN_KTAT","VRATCN_KTBL","VRATCN_KTGT1","VRATCN_KTGT2","VRATCN_KTGT3","VRATCN_KTSM","VRATCN_KTSY","VRATCN_KTTT1","VRATCN_KTTT2","VRATCN_KTWM1","VRATCN_KTWM2","VRATCN_KT_TX_A2","VRATCN_KT_TX_A3","VRATCN_KT_TX_A4","VRATCN_LYHW1","VRATCN_LYHW2","VRATCN_LYHW3","VRATCN_MBDD1","VRATCN_MBDD2","VRATCN_MBEP1","VRATCN_MBEP2","VRATCN_MLBA1","VRATCN_MLBA2","VRATCN_MLGT1","VRATCN_MLGT2","VRATCN_MLSY1","VRATCN_MLSY2","VRATCN_MLTG","VRATCN_ML_TX_A1","VRATCN_ML_TX_A2","VRATCN_MSDD1","VRATCN_MSDD2","VRATCN_MSLT","VRATCN_MSUT","VRATCN_NPBL","VRATCN_NPFB","VRATCN_RCBU0X1","VRATCN_RCHO","VRATCN_RORT1","VRATCN_RORT4","VRATCN_RORW","VRATCN_ROSM","VRATCN_ROTS","VRATCN_ROTT","VRATCN_RO_TX_A1","VRATCN_RO_TX_A2","VRATCN_RTBT","VRATCN_RTRO1","VRATCN_RTRO4","VRATCN_RWRO","VRATCN_RWTT","VRATCN_SHBE","VRATCN_SHDD","VRATCN_SHGN1","VRATCN_SHGN3","VRATCN_SMDD1","VRATCN_SMDD2","VRATCN_SMKT","VRATCN_SMRO3","VRATCN_SMSY1","VRATCN_SMSY2","VRATCN_SMTT1","VRATCN_SMTT2","VRATCN_SM_TX_F2","VRATCN_SM_TX_H1","VRATCN_SM_TX_H2","VRATCN_STAR","VRATCN_SYKT","VRATCN_SYML1","VRATCN_SYML2","VRATCN_SYSM1","VRATCN_SYSM2","VRATCN_TGBA","VRATCN_TGML","VRATCN_TSRO","VRATCN_TSTT","VRATCN_TTBT1","VRATCN_TTBT3","VRATCN_TTEP","VRATCN_TTKT1","VRATCN_TTKT2","VRATCN_TTRO","VRATCN_TTRW","VRATCN_TTSM1","VRATCN_TTSM2","VRATCN_TTTS","VRATCN_WBBA","VRATCN_WBHO","VRATCN_WMFB1","VRATCN_WMFB2","VRATCN_WMKT1","VRATCN_WMKT2","VRATCN_WODD","VRATCN_WOJN060","VRATCN_YPHW1","VRATCN_YPHW2","VRATCN_YPRO5","VRATCN_YPRO6","VRATCN_YPRO7","VRATCN_YPRO8","VRATEM_ARBR","VRATEM_ARST","VRATEM_BANBR","VRATSE_WOJN060"]},"VALIDFROM":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date that this record is applies from (inclusive)","examples":["2007/07/09 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EQUIPMENTID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":false,"comment":"A unique identifier for this equipment at this substation, and based on its type","examples":["01","0X1","996","110KV_710","110KV_731","110KV_732","110KV_745/1","110KV_746/1","110KV_757","110KV_758","110KV_776","110KV_791","110KV_F907","132KV_7128/1","132KV_7168","132KV_7183","132KV_7249","132KV_7276","132KV_7325","132KV_7349","132KV_7350","132KV_7389","1H","1TL","1_H18","1_H4","275KV_831","275KV_871","275KV_8819","275KV_8823","275KV_8826","275KV_8845","2M","2TL","2_H4","330KV_9907","3H","3J","3W","3_H4","4H","4_H18","5A3","5A4","5A5","5A6","5A7","5_H14","6H","8L","8M","94K","94Y","96C","99A","99F","99M","9R1","9R2","9U8","9U9","9W1","9W2","9W3","9W6","A1TR_220","A1TR_500","A2TR","A2TR_220","A2TR_500","A3TR","A3TR_500","A4TR","A4TR_500","ART_BGR_66","ART_STL_66","ATPTOA_T","ATS_BLTS_220","ATS_KTS_220","BAN_BGR_66","BATS_BETS_220","BATS_MLTS1_220","BATS_MLTS2_220","BATS_TGTS_220","BATS_WBTS_220","BETS_KGTS_220","BETS_SHTS_220","BLTS_FBTS_220","BLTS_KTS_220","BLTS_NPSD_220","BRIRED_T","BTS_RTS_220","BTS_TTS1_220","BTS_TTS3_220","BUNHUM_T","BUNPAR_1","BUNSNW_T","BU_EB","BU_HM","BU_PL","BW_LF","CANROB_1","CA_WY","CBTS_HWTS4_500","CBTS_ROTS4_500","CHGTAB_1","CS_CR1","CS_CR2","CS_CR_RI/1","CS_CR_RI/2","CS_RI","CULMBK_T","CULWCE_1","CULWCE_2","CULWHY_1","DDTS_GNTS1_220","DDTS_GNTS3_220","DDTS_MBTS1_220","DDTS_MBTS2_220","DDTS_MSS1_330","DDTS_MSS2_330","DDTS_SHTS_220","DDTS_SMTS1_330","DDTS_SMTS2_330","DDTS_WOTS_330","DVPBRI_1","DVPBUN_1","DVPCAN_1","DVPCUL_2","DVPROB_2","DVPWHY_1","EPS_MBTS1_220","EPS_MBTS2_220","EPS_TTS_220","F2TR_330","FA_JB","FA_QU_SR_HM/4","FBTS_NPSD_220","FBTS_WMTS1_220","FBTS_WMTS2_220","GNTS_SHTS1_220","GNTS_SHTS3_220","GO_CS1","GO_CS2","GTS_KTS1_220","GTS_KTS2_220","GTS_KTS3_220","GTS_MLTS1_220","GTS_MLTS2_220","GTS_PTH1_220","GTS_PTH2_220","GT_BB1","GT_BB2","H1TR","H2TR","H3TR","HAVMVE_1","HA_GT1","HA_GT2","HA_NW1","HA_NW2","HA_TR1","HA_TR2","HOTS_RCTS_220","HOTS_WBTS_220","HUMWAT_1","HWPS_JLTS1_220","HWPS_JLTS2_220","HWPS_JLTS3_220","HWPS_JLTS4_220","HWPS_ROTS1_220","HWPS_ROTS2_220","HWPS_TEE1_220","HWPS_YPS1_220","HWPS_YPS2_220","HWTS_LYPS1_500","HWTS_LYPS2_500","HWTS_LYPS3_500","HWTS_ROTS3_500","HWTS_SMTS1_500","HWTS_SMTS2_500","HYTS_SESS1_275","HYTS_SESS2_275","KEIKIN_1","KEISNG_1","KILCRO_1","KILNOF_1","KINPEW_1","KTS_SMTS_500","KTS_SYTS_500","KTS_TTS1_220","KTS_TTS2_220","KTS_WMTS1_220","KTS_WMTS2_220","LEFTOB_1","LF_RI1","LF_RI2","LI_CL_RE_CS1","LI_CS1","LI_CS2","M1TR","M2TR","MA2ANC_T","MA3MAN_T","MAGHAV_1","MBKYAD_T","MB_NN","MIKANC_T","MINWAT_1","MLTS_SYTS1_500","MLTS_SYTS2_500","MLTS_TGTS_220","MOBTAB_1","MOKROB_1","MONBER_1","MTGBLA_1","MW1NWB_2","MW4WLE_1","NN_CR","NN_CS","NWBMON_1","NWBMON_2","NW_SD_DE/3","OSBTOA_3","OSBTOA_4","PARMAG_1","PARPGW_1","PARTOA_4","PA_UL","PEWSES_1","PLBDVP_1","PM_HA1","PM_HA2","PM_HA3","PM_HA4","PM_SH","PO_PM5","PPTLEF_1","PPTPGW_1","REDBUN_T","ROBMW3_2","ROBMW4_2","ROBNWB_1","ROSPAR_1","ROTS_RTS1_220","ROTS_RTS4_220","ROTS_RWTS_220","ROTS_SMTS3_500","ROTS_TSTS_220","ROTS_TTS_220","ROTS_YPS5_220","ROTS_YPS6_220","ROTS_YPS7_220","ROTS_YPS8_220","RWTS_TTS_220","SESMTG_1","SH_BU1","SH_BU2","SH_FA1","SH_FA2","SH_GT1","SH_GT2","SH_PA","SH_PA_UL/1","SH_PA_UL/2","SMTS_SYTS1_500","SMTS_SYTS2_500","SMTS_TTS1_220","SMTS_TTS2_220","SNGBLA_1","SNGMAY_T","SNGSES_T","SNWHUM_T","T1","T2","T3","T4","TABKEI_1","TABKEI_2","TABSES_1","TABSES_2","TA_MB","TA_NN1","TA_NN2","TEMROS_1","TOAKIL_1","TOAMAG_1","TOANOF_1","TOBCHG_1","TSTS_TTS_220","TUNTAB_1","TU_LE_WA1/1","TU_LE_WA1/2","TU_LE_WA1/3","TU_LE_WA2/1","TU_LE_WA2/3","TU_TA1","TU_TA2","T_1","T_2","T_3","T_4","T_5","UL_EB","WATTEM_1","WA_BW","WA_PM2","WHYWCE_1","WHYYAD_1","X5/1","X5/3","YADPLT_1"]},"EQUIPMENTTYPE":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"The type of equipment. Valid values are:\nLINE = Line\nTRANS = Transformer\nCB = Circuit breaker\nISOL = Isolator\nCAP = Capacitor\nREAC = Reactor\nUNIT = Unit","examples":["LINE","TRANS"]},"ISDYNAMIC":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"One of:\n1 = Normally uses dynamic ratings\n0 = No dynamic ratings, static ratings are used","examples":["0","1"],"is_integer":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed","examples":["2007/07/09 12:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RATINGLEVEL":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":false,"comment":"The rating level of the value used, one of:\nNORM = Continuous rating value. Applied under pre-contingent conditions.\nEMER = Continuous rating value. Applied under pre-contingent conditions\nLDSH = Load Shedding","examples":["EMER","LDSH","NORM"]},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The region that this rating is for","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":false,"comment":"The substation the equipment is located at","examples":["ANG_CK","ARMIDALE","ART","ATS","AVON","BALRANLD","BAN","BANNABY","BATS","BAYSWATR","BELL_BAY","BERRI","BETS","BLANCH","BLTS","BRINKW","BTS","BUNGAM","BURNIE","BURONGA","B_WATER","CANBERRA","CANOWI","CAPITAL","CATAGNYA","CBTS","CHAPEL","CH_GDN","CLUNY_T","COFFS","CREEK_RD","CREEK_T","CROYDN","CULTAN","DAPTO","DARL_PT","DAVENP","DDTS","DERBY","DUMARESQ","EPS","ERARING","FARRELL","FBTS","GNTS","GORDON","GTS","G_TOWN","H11_NEBO","H12_MT_E","H13_ROSS","H14_MRDG","H16_RLEA","H18_TRNG","H1_SBK_B","H23_UKED","H24_CALV","H2_SPINE","H31_MDNR","H38_GDNA","H4_MUGBA","H51_SBKE","HADSPEN","HMPSHIRE","HOTS","HUMMOC","HWPS","HWTS","HYTS","H_VALL","INGLBURN","JINDERA","JLTS","KANGAROO","KEITH","KEMPS_CK","KGTS","KILBUR","KINCRA","KTS","LE_FEV","LIAPOOTA","LIDDELL","LINFARNE","LISM132","LISMORE","LYPS","L_ECHO","MAGILL","MANNUM","MARULAN","MAYURA","MBTS","MDWBANK","MINTAR","MLTS","MOBILO","MOKOTA","MONASH","MT_GAM","MT_PIPER","MUNMORAH","MURRAY","MUSBK330","MW_1","MW_3","MW_4","NAMBUCCA","NEWCSTLE","NORWOOD","NPSD","N_NRFOLK","N_OSBN","N_W_B","PALMSTN","PALOONA","PARA","PELI_P","PENO_W","PGWEST","PT_L_T","P_AD_N","R3_BULLI","R4_MILLM","RALEIGH","RCTS","RISDON","ROTS","ROTS_500","RTS","RWTS","R_TOWN","SHEFIELD","SHTS","SMTS","SNUGGY","SYD_STH","SYD_WEST","SYTS","S_EAST","S_TOWN","T134_CDW","T13_CHIN","T145_TVL","T147_TAN","T155_WDR","T194_CLB","T37_COLL","TALAWARA","TAMWORTH","TARRALEA","TEMPLE","TGTS","TIPS_A","TIPS_B","TOMAG132","TOMAGO","TREVALYN","TSTS","TTS","TUGGERAH","TUMUT1_2","TUMUT3","TUNGATIN","T_BEND","ULVERSTN","URANQNTY","VALES_PT","WADAMANA","WAGGA330","WBTS","WELLNGTN","WHYA_C","WHY_T","WMTS","WOLLAR","WOTS","WWANG","W_LOO","YADNAR","YASS","YPS"]},"VALIDTO":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date that this record applies until (exclusive)","examples":["2013/05/24 15:55:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_RATING%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":53716,"decompressed_size_all_time":13447200},"visibility":"Public"},"NETWORK_REALTIMERATING":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"REALTIMERATING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#37"],"comment":"The NETWORK_REALTIMERATING table shows the equipment rating values in MVA used as inputs to constraints in the dispatch solution. This includes values for both static and dynamic ratings. The NETWORK_RATING table can be used to determine the physical equipment the rating is for based on the SPD_ID value.","primary_keys":["SETTLEMENTDATE","SPD_ID"],"columns":{"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The dispatch interval the rating applies to","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SPD_ID":{"sql_type":"VARCHAR(21)","pl_type":"str","mandatory":true,"comment":"ID defining this data source for use in constraints"},"RATINGVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":true,"comment":"The defined equipment rating value in MVA","is_float":true}},"visibility":"Public"},"NETWORK_STATICRATING":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"STATICRATING","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#43"],"comment":"NETWORK_STATICRATING lists the static rating values that will apply for a Rating Application ID.\nThis data does not provide information for when the rating actually applies in the NEM. This is dependent on the Rating Application definition.\nFor information on the Rating Applications please refer to the information published on the AEMO website under the topic \"Transmission Equipment Ratings\". The Rating Applications are referred to as Alternate Value Application Ratings.\nRatings that normally use dynamic values will also have static rating values defined. These are used as a fallback if the dynamic rating fails.","primary_keys":["APPLICATIONID","EQUIPMENTID","EQUIPMENTTYPE","RATINGLEVEL","SUBSTATIONID","VALIDFROM"],"indexes":[["LASTCHANGED"]],"columns":{"APPLICATIONID":{"sql_type":"VARCHAR(20)","pl_type":"str","mandatory":true,"comment":"The applicationid which defines the application timeframes of this rating.","examples":["BENDIGO_10","BENDIGO_10D","BENDIGO_15","BENDIGO_15D","BENDIGO_20","BENDIGO_20D","BENDIGO_25","BENDIGO_25D","BENDIGO_30","BENDIGO_30D","BENDIGO_35","BENDIGO_35D","BENDIGO_40","BENDIGO_40D","BENDIGO_45","BENDIGO_45D","BENDIGO_5","BENDIGO_5D","DDRANG_10D","DDRANG_15D","DDRANG_20D","DDRANG_25D","DDRANG_30D","DDRANG_35D","DDRANG_40D","DDRANG_45D","DDRANG_5D","DEDERANG_10","DEDERANG_15","DEDERANG_20","DEDERANG_25","DEDERANG_30","DEDERANG_35","DEDERANG_40","DEDERANG_45","DEDERANG_5","HAZ_WOOD_10","HAZ_WOOD_10D","HAZ_WOOD_15","HAZ_WOOD_15D","HAZ_WOOD_20","HAZ_WOOD_20D","HAZ_WOOD_25","HAZ_WOOD_25D","HAZ_WOOD_30","HAZ_WOOD_30D","HAZ_WOOD_35","HAZ_WOOD_35D","HAZ_WOOD_40","HAZ_WOOD_40D","HAZ_WOOD_45","HAZ_WOOD_45D","HAZ_WOOD_5","HAZ_WOOD_5D","KEILOR_10","KEILOR_10D","KEILOR_15","KEILOR_15D","KEILOR_20","KEILOR_20D","KEILOR_25","KEILOR_25D","KEILOR_30","KEILOR_30D","KEILOR_35","KEILOR_35D","KEILOR_40","KEILOR_40D","KEILOR_45","KEILOR_45D","KEILOR_5","KEILOR_5D","MRABOOL_10D","MRABOOL_15D","MRABOOL_20D","MRABOOL_25D","MRABOOL_30D","MRABOOL_35D","MRABOOL_40D","MRABOOL_45D","MRABOOL_5D","M_RABOOL_10","M_RABOOL_15","M_RABOOL_20","M_RABOOL_25","M_RABOOL_30","M_RABOOL_35","M_RABOOL_40","M_RABOOL_45","M_RABOOL_5","NSWSUM","NSWWIN","N_AUT/SPR_D","N_AUT/SPR_N","N_SUM_D","N_SUM_N","N_WIN_D","N_WIN_N","REDCLIFF_10D","REDCLIFF_15D","REDCLIFF_20D","REDCLIFF_25D","REDCLIFF_30D","REDCLIFF_35D","REDCLIFF_40D","REDCLIFF_45D","REDCLIFF_5D","ROWVILLE_10","ROWVILLE_15","ROWVILLE_20","ROWVILLE_25","ROWVILLE_30","ROWVILLE_35","ROWVILLE_40","ROWVILLE_45","ROWVILLE_5","SINGLE","TASSUM","TASWIN","TAS_CENTL_0","TAS_CENTL_10","TAS_CENTL_15","TAS_CENTL_20","TAS_CENTL_25","TAS_CENTL_30","TAS_CENTL_35","TAS_CENTL_40","TAS_CENTL_5","TAS_NORTH_0","TAS_NORTH_10","TAS_NORTH_15","TAS_NORTH_20","TAS_NORTH_25","TAS_NORTH_30","TAS_NORTH_35","TAS_NORTH_40","TAS_NORTH_5","TAS_NW_0","TAS_NW_10","TAS_NW_15","TAS_NW_20","TAS_NW_25","TAS_NW_30","TAS_NW_35","TAS_NW_40","TAS_NW_5","TAS_SOUTH_0","TAS_SOUTH_10","TAS_SOUTH_15","TAS_SOUTH_20","TAS_SOUTH_25","TAS_SOUTH_30","TAS_SOUTH_35","TAS_SOUTH_40","TAS_SOUTH_5","TAS_WEST_0","TAS_WEST_10","TAS_WEST_15","TAS_WEST_20","TAS_WEST_25","TAS_WEST_30","TAS_WEST_35","TAS_WEST_40","TAS_WEST_5","VICSUM","VICWIN"]},"EQUIPMENTID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"A unique identifier for this type of equipment at this substation","examples":["01","3H","965","6H","ATS_BLTS_220","BATS_BETS_220","BATS_MLTS1_220","BATS_MLTS2_220","BATS_TGTS_220","BETS_KGTS_220","BETS_SHTS_220","BTS_RTS_220","CA_WY","CBTS_HWTS4_500","CBTS_ROTS4_500","DDTS_GNTS3_220","DDTS_MBTS1_220","DDTS_MSS1_330","DDTS_MSS2_330","DDTS_SHTS_220","DDTS_SMTS1_330","DDTS_WOTS_330","EPS_MBTS1_220","EPS_MBTS2_220","F2TR_330","FA_JB","GNTS_SHTS1_220","GNTS_SHTS3_220","GO_CS1","GO_CS2","GTS_KTS1_220","GTS_KTS2_220","GTS_KTS3_220","GTS_MLTS1_220","GTS_MLTS2_220","H1TR","H2TR","H3TR","HA_GT1","HA_GT2","HOTS_RCTS_220","HWPS_JLTS3_220","HWPS_JLTS4_220","HWPS_YPS1_220","HWPS_YPS2_220","HWTS_LYPS1_500","HWTS_LYPS2_500","HWTS_LYPS3_500","HWTS_ROTS3_500","HWTS_SMTS1_500","HWTS_SMTS2_500","KTS_SMTS_500","KTS_SYTS_500","KTS_WMTS1_220","KTS_WMTS2_220","LF_RI1","LF_RI2","MLTS_SYTS1_500","MLTS_SYTS2_500","PM_HA1","PM_HA2","PM_HA3","PM_HA4","ROTS_SMTS3_500","ROTS_YPS8_220","SH_FA1","SH_FA2","SH_GT1","SH_GT2","SH_PA","SMTS_SYTS1_500","SMTS_SYTS2_500","T1","T2","T3","T4","TA_MB","TA_NN1","TA_NN2","TU_LE_WA1/1","TU_LE_WA1/3","TU_LE_WA2/1","TU_LE_WA2/3","TU_TA1","TU_TA2","UL_EB","WA_BW","WA_PM2"]},"EQUIPMENTTYPE":{"sql_type":"VARCHAR(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of equipment. Valid values are:\nLINE = Line\nTRANS = Transformer\nCB = Circuit breaker\nISOL = Isolator\nCAP = Capacitor\nREAC = Reactor\nUNIT = Unit","examples":["LINE","TRANS","TX"]},"RATINGLEVEL":{"sql_type":"VARCHAR(10)","pl_type":"str","mandatory":true,"comment":"The rating level of the value used, one of:\nNORM = Continuous rating value. Applied under pre-contingent conditions.\nEMER = Continuous rating value. Applied under pre-contingent conditions\nLDSH = Load Shedding","examples":["LDSH","NORM"]},"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"The substation the equipment is located at","examples":["ARMIDALE","BATS","BAYSWATR","BETS","BLTS","BTS","BURNIE","CANBERRA","CATAGNYA","CBTS","CHAPEL","DAPTO","DDTS","EPS","ERARING","FARRELL","GNTS","GORDON","GTS","G_TOWN","HADSPEN","HOTS","HWPS","HWTS","JINDERA","KANGAROO","KEMPS_CK","KTS","LIDDELL","LYPS","MBTS","MLTS","MURRAY","MUSBK330","N_NRFOLK","PALMSTN","RCTS","RISDON","ROTS_500","SHEFIELD","SHTS","SMTS","SYTS","TAMWORTH","TARRALEA","TGTS","TUMUT1_2","TUMUT3","TUNGATIN","ULVERSTN","WADAMANA","WOTS","YASS","YPS"]},"VALIDFROM":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date that this record is applies from (inclusive)","examples":["2011/02/18 08:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed.","examples":["2011/02/18 08:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RATINGVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The rating value in MVA that applies. This may be positive or negative depending on which side of the nominal MW flow direction the rating value applies.\nFlow into a transmission device is positive, flow out of the device is negative.","examples":["0.01","105","3862.5","2598"],"is_float":true},"VALIDTO":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date that this record applies until (exclusive)","examples":["2013/05/23 11:10:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_STATICRATING%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1670117,"decompressed_size_all_time":422177470},"visibility":"Public"},"NETWORK_SUBSTATIONDETAIL":{"package":"NETWORK","pdr_config":{"mappings":[{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"SUBSTATIONDETAIL","VERSION":1},{"REPORT_NAME":"NETWORK","REPORT_SUB_TYPE":"SUBSTATIONDETAIL","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec73.htm#51"],"comment":"NETWORK_SUBSTATIONDETAIL sets out the attributes of sub-stations across time","primary_keys":["SUBSTATIONID","VALIDFROM"],"indexes":[["LASTCHANGED"]],"columns":{"SUBSTATIONID":{"sql_type":"VARCHAR(30)","pl_type":"str","mandatory":true,"comment":"ID uniquely identifying this substation","examples":[" FORBES","21TEE","92ZTEE","947TEE","94K_TEE","ABC_B","AC","ACTBEL","ACTBRU","ACTCAU","ACTCE","ACTCIV","ACTELK","ACTGCK","ACTGIL","ACTLAT","ACTTHEO","ACTWANN","ACTWOD","AL","ALBURY","ALDING","ALSTONVL","ANGAST","ANG_CK","ANM","APD","APS","ARDN_W","ARMIDALE","ART","ARTHURS","ARTS","ARWF","ASCOT","AT.ARWF","ATHOL","ATS","AVOCA","AVON","A_VALE","BACK_C","BALLINA","BALRANLD","BAN","BANGOWF","BANNABY","BARK_I","BAROOT","BASTYAN","BATS","BAYSWATR","BDSS","BEGA","BELALI","BELL_BAY","BENDEELA","BERESFLD","BERRI","BERYL","BERYL_SF","BETS","BFIELD_N","BFIELD_W","BGWF","BLANCH","BLGT","BLLC","BLOWERG","BLTS","BLUFF_WF","BLYBSS","BNGALORA","BOAMBEE","BOCOROCK","BOGBRI_E","BOGBRI_N","BOYER","BRAE_PS","BRINKW","BRKNHILL","BRNSDE","BRT","BRYBNKSS","BRYBNKWF","BTS","BUNGAM","BUNNERNG","BURNIE","BURONGA","BURRINJK","BUTLERS","B_POOL","B_WATER","B_WOOD","CAMBTN","CAMELLIA","CAMPBELL","CANBERRA","CANOWI","CANTERBY","CAPITAL","CAPRAL","CATAGNYA","CBTS","CDN","CETHANA","CHAPEL","CHARMHVN","CHARTWRS","CHCRPTEE","CHLTNM","CHULLORA","CH_GDN","CITY_W","CLAREN","CLAR_G","CLAR_N","CLC","CLEM_G","CLPS","CLRMT_SF","CLUNY","CLUNY_T","CLVIEW","COFFS","COLLECWF","COLMBLLY","COLONGRA","COMALCO","COOMA","COOR_2","COOR_S","CORO","COROWA","COWRA","CPR_EAST","CPTS","CREEK_RD","CRONULLA","CROYDN","CROYDTEE","CROY_P","CRTS","CRUDNEWF","CUD_PK","CULC_SF","CULLERIN","CULTAN","CULTAN_E","CWTS","CWWF","DALRYM","DAPTO","DARL_PT","DAVENP","DCPKSTEE","DDTS","DENILIQN","DERBY","DERWENT","DEVILS_G","DEVNPORT","DINAWAN","DORRIE","DPS","DRY_CK","DUBBO132","DUBOWEST","DUBO_STH","DUNOON","EAST_LIS","EDINBR","EDVL_SF","ELECTRNA","ELIZ_D","ELIZ_H","ELIZ_S","ELTS","EMEROO","EMRLDWST","EMU_BAY","EPS","ERARING","ERTS","EVANST","EWINGSDL","E_TCE","FARRELL","FBTS","FINDON","FINLEY","FISHER","FLIN_P","FORBES","FULGDN","GADARA","GETS","GEURIE","GLANV","GLDFORD","GLEN_INN","GLEN_N","GNTS","GOLD_G","GORDON","GOSFORD","GOULBURN","GREEN_SQ","GRIFFITH","GRWF","GTS","GUNDH_SF","GUNNEDAH","GUNNING","GUTHEGA","GWSF","GYDR_WF","G_TOWN","H108_TUM","H110_BSD","H114_WB2","H116_KWF","H11_NEBO","H125_JND","H126_MUR","H12_MT_E","H139_STB","H13_ROSS","H154_SNB","H162_BNB","H169_EUR","H16_RLEA","H18_TRNG","H1_SBK_B","H21_MRRE","H29_STAN","H2_SPINE","H31_MDNR","H35_STHM","H38_GDNA","H39_WORE","H40_WURD","H48_B2PS","H4_MUGBA","H56_YBLS","H58_LARC","H5_WLGA","H62_ABMN","H63_TBAR","H67_CALR","H71_DDPS","H72_BKST","H73_RAGL","H75_KUMP","H76_WAND","H77_CLMB","H78_ORAN","H82_BLYD","H85_COOP","H86_DDSF","H90_TLYS","H92_K2H","H93_GUMN","H98_WBWF","H9_PLMWD","HADSPEN","HALHIL","HALLET","HAL_WF","HARROW","HAYMARKT","HBSH_BAY","HENLEY","HGTS","HILLCR","HILLSTON","HIND_S","HMPSHIRE","HOLROYD","HOTS","HRN_WF","HTS","HUGH","HUME","HUMMOC","HVEWME","HWPS","HWTS","HYTS","H_HILL","H_VALL","INGLBURN","INVERELL","I_FARM","JBUTTERS","JINDABYN","JINDERA","JLA","JLGSA","JLGSB","JLTS","JRDNE_CK","JUNEE","JUNEE_SF","KADINA_E","KANGAROO","KANM_M","KEITH","KEMPSEY","KEMPS_CK","KENT_T","KEPG","KERMANDE","KESWIC","KGTS","KIAMALSF","KILBUR","KILB_S","KILKEN","KINCRA","KINGSTON","KNIGHTS","KOGAN_PS","KOOLKHAN","KOTS","KTS","KURNELL","KURRI","KURRI_ZS","K_WOOD","LADB_G","LANECOVE","LARG_N","LAWSON","LDL_BESS","LEMONTYM","LENNOX_H","LE_FEV","LIAPOOTA","LIDDELL","LINFARNE","LINPKT","LIN_GP","LIN_PK","LISM132","LISMORE","LISM_SS","LIVERPL","LMITCH","LVN","LY","LYGS","LYPA","LYPB","LYPS","L_BONY","L_ECHO","MACARTHR","MACKSVIL","MACQPARK","MAGILL","MAKNTOSH","MAMRE","MANILDRA","MANNUM","MARCKVLE","MAROUBRA","MARULAN","MARYR_SF","MARYVALE_SF","MASONPRK","MAYURA","MA_1","MA_2","MA_3","MBH_1","MBH_2","MBH_3","MBTS","MCLFTEE","MC_L_F","MDLBCK","MDWBANK","MEADOWBK","METZ_SF","MILLBR","MILLM_PS","MINTAR","MITCHELL","MKPS","MLINK_B","MLNK_B","MLRC","MLSW","MLTS","MOBILO","MOKOTA","MOLONG","MONASH","MOPS","MOREE","MORNGTON","MORP_E","MOWBRAY","MPS","MRTS","MTS","MT_BAR","MT_B_S","MT_DRUIT","MT_GAM","MT_GUN","MT_LOC","MT_MIL","MT_PIPER","MT_S_PS","MULLUMB","MULWALA","MUNMORAH","MUNYANG","MURRAY","MURRUMBR","MUSBK132","MUSBK330","MVILLE","MWF","MWTS","MW_1","MW_2","MW_3","MW_4","MYT","NADELTEE","NAMBUCCA","NARRABRI","NARRAND","NDSC_N","NEPEAN","NEUROO","NEVERTIRE","NEVRT_SF","NEWCSTLE","NEWEN_SF","NEWTON","NOAR_C","NORTHF","NORWD","NORWOOD","NO_B_H","NPS","NPSD","NRCS","NRICHTEE","NRMN_STH","NYNGN132","NYNGN_SF","N_ADEL","N_HOBART","N_NRFOLK","N_OSBN","N_RICH","N_UNLY","N_W_B","OAKEY_PS","OAKEY_SF","OAKLND","OCPL","OLYM_N","OLYM_W","ORANGE","ORANGE_N","ORA_BESS","OURIMBAH","PALMSTN","PALOONA","PANAPTEE","PANORA","PANORAMA","PARA","PARA_G","PARKES","PARLWE","PEAKHRST","PELI_P","PEL_PS","PENFLD","PENO_W","PENRITH","PGWEST","PIEMAN","PIMBA","PLAY","PLMGPTEE","PLYMPT","POATINA","PROM_H","PROSP","PRTS","PTH","PT_LATTA","PT_L_T","PT_MCQAR","PT_NOA","PT_STA","PWSPT_T","P_ADEL","P_AD_N","P_PA_N","P_PIRI","P_PIRI_S","QNSTOWN","QNSTWN","QPS","QRNPK_SF","QUE","QUEANBYN","R13_MNWFMACNT_WF","R14_TUMM","R15_MISS","RAILTON","RALEIGH","RAVINE","RCTS","REAC_1B_220","REDBANK","REDHIL","REECE","REGENTVL","REPULSE","RISDON","RIVERINA","ROKEBY","ROMA_PS","ROOKWOOD","ROSEBERY","ROTHBURY","ROTS","ROTS_500","ROWALLAN","RSWTHY","RTS","RUBA","RWTS","RYE_PARK","RYE_P_WF","R_TOWN","S","S2_HALYS","S3_GNBNK","S5_WESTD","SALISB","SAPWF","SAVRIVER","SBK_A_PS","SBK_B_PS","SBK_C_PS","SBK_D_PS","SBK_E_PS","SCOTDALE","SEACOM","SEBAS_SF","SHEFIELD","SHE_PK","SHTS","SINGLETN","SLEAFD","SMITHTON","SMTS","SNAP_P","SNOWY1","SNUGGY","SNW_NTH","SNW_STH","SOMERSBY","SORELL","SPRNGHLL","SPS","SRCS","SSCMA","SSCOR","SSGBS","SSGFN","SSMMC","SSMTN","SSNGE","SSNSD","SSNVR_T","SSRPT_PS","SSRVW","SSS","SSSFD","SSSPD","SSSPO","SST29","SSVPK","SSWED","SSWRD","SSYTA","ST","STAN_PS","STARWOOD","STEEPLE","STH_LISM","STL","STOCKDIL","STON_P","STROUD","STS_WF","STUBO_SF","STUDLAND","ST_MARYS","ST_PETER","SUMFD1","SUMFD2","SUNRY_SF","SUNTP_SF","SVTS","SYD_EAST","SYD_NTH","SYD_STH","SYD_WEST","SYTS","S_EAST","S_TOWN","St.T158_YAL","T100_RCK","T104_STN","T105_OON","T10_YARR","T110_PKD","T111_NOR","T112_MTM","T116_TRN","T120_KOR","T123_MUN","T124_TRV","T128_RBA","T129_EDM","T130_BCK","T137_NGY","T140_TZC","T141_PVA","T142_TEN","T145_TVL","T146_OAK","T147_TAN","T152_G_S","T153_QAW","T155_WDR","T157_IS","T158_YAL","T159_LKL","T160_SMR","T161_ALG","T162_BND","T163_RLS","T166_GCK","T16_NAMB","T171_ELR","T172_MND","T173_ARM","T174_TRA","T175_BLB","T176_LCK","T177_KCK","T178_SCK","T182_QLS","T187_RLD","T188_DND","T189_OKY","T192_QMP","T193_CLS","T194_CLB","T199_YAR","T200CMPS","T209_BLF","T210_DUR","T211_WYC","T217_CBC","T219_WCK","T21_QAL","T220_COL","T221_WTG","T225_CCK","T236_MML","T23_ROCK","T241_LKR","T24_RUNC","T254_BNA","T255_RRS","T256_GRL","T257_FRI","T258_WCK","T271_WSB","T27_MRA","T280_DRL","T285_MCR","T287_DWF","T293_WGA","T34_MRNB","T39_PROS","T43_STWB","T48_TLLY","T4_SBK_A","T55_TURK","T56_TV_S","T58_WRCK","T60_STAN","T61_PAND","T69_NLDS","T74_GNTH","T75_NRNG","T80_REDB","T83_ROMA","T93_CNTH","T94_TVE","TALAWARA","TAMAR_PS","TAMWORTH","TARALGA","TAREE","TARRALEA","TATNTEE","TBTS","TEE1","TEMCO","TEMORA","TEMPLE","TEMP_W","TENTFLD","TGTS","THEBAR","TIE_DVPL","TIPS_A","TIPS_B","TI_BESS","TI_N","TOMAG132","TOMAGO","TONS_P","TREVALYN","TRIABUNA","TRIBUTE","TRNGN_PS","TRNG_PS","TRTS","TSTS","TTS","TUGGERAH","TUMUT132","TUMUT1_2","TUMUT3","TUNGATIN","TUNKIL","TVLLE_PS","TYA","T_BEND","T_T_G","ULVERSTN","URAIDL","URAIDT","URALLA","URANQNTY","UUNG_SS","UUNG_WF","VALES_PT","VBB","VINEYARD","Virginia","WADAMANA","WAGGA132","WAGGA330","WAGGANTH","WALAWALA","WARRAGAM","WARRIMOO","WARTAH_T","WATE_E","WATT_P","WAT_WF","WAYATINA","WBTS","WDP","WDSK_STH","WDVILL","WELLNGTN","WEL_N_SF","WES_VALE","WETH_PRK","WETS","WHITSTEE","WHIT_S","WHYA_C","WHY_T","WILLMSDL","WILLUN","WILMOT","WIN","WISF","WIV_PS","WKPS","WMTS","WN","WOES","WOLLAR","WOLLAR_W","WOODFD","WOOMER","WOTS","WRH_WEST","WST_GSFD","WWANG","WWTH_PRK","WWYAL_SF","WYA_SF","WYONG","W_JEMALN","W_LIVRPL","W_LOO","YADNAR","YANCO","YASS","YDW","YENDON","YPS","Z13_BCMB","Z34_BGSF","Z35_CCB","Z4_CGWF"]},"VALIDFROM":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"The record is valid from this date (inclusive)","examples":["2003/04/28 16:51:08.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"DESCRIPTION":{"sql_type":"VARCHAR(100)","pl_type":"str","mandatory":false,"comment":"Description of the substation","examples":["94K_Tee","Abermain(H162)","Abermain(H62)","ActewAGL Belconnen 132kV","ActewAGL Bruce 132kV","ActewAGL Causeway 132kV","ActewAGL City East 132kV","ActewAGL Civic 132kV","ActewAGL Gilmore 132kV","ActewAGL Gold Creek 132kV","ActewAGL Latham 132kV","ActewAGL Theodore 132kV","ActewAGL Wanniassa 132kV","ActewAGL Woden 132kV","Adelaide Brighton Cement 66kV","Albury 132kV","Alcoa/portland 500kV","Aldinga 66kV","Algester (T161)","Alstonville 66/11kV","Altona 220kV","Altona 66kV","Altona Chemicals 66kV","Angas Creek 132kV","Angaston","Angle Vale 66kV","Anglesea Ps 220kV","Anm 132kV","Aramara","Ararat","Ararat 66kV","Ararat WF (TempForVds)","Ararat Wind Farm","Ardrossan West 132kV","Armidale 330kV","Arthurs Lake","Ascot Park 66kV","Athol Park 66kV","Avoca","Avon 330kV","BLUFF/PORCUPINE","Back Callington","Baggabri North 132kV Substation","Bairnsdale Ps","Ballarat 220kV","Ballarat 66kV","Ballina 66/11kV","Balranald 220/22kV Substation","Bango WF","Bannaby 500kV","Barker Inlet PS","Baroota 132kV","Basslink Loy Yang","Bastyan","Bayswater 330kV","Beaconsfield 330kV","Beaconsfield North 132kV","Bega","Belalie","Bell Bay","Bendeela Ps","Bendigo 220kV","Beresfield 132kV eA","Berri 132kV","Berri C/S","Berrybank SS","Berrybank TG","Beryl 132kV","Beryl SF","Blackpool 66kV","Blackstone (H72)","Blackwood 66kV","Blanch 132kV","Blowering Ps 132kV","Bluff (T209)","Blyth BESS","Blythdale","Boambee South 132kV","Boat Creek 132kV","Boco Rock Wind Farm","Boggabri East","Bolingbroke","Boyer","Braemar Power Station (H47)","Braemar Power Station 2 (H48)","Bridgewater","Bright 66kV","Brinkworth 275kV","Broadsound H110 275kV","Broken Hill 220kV","Brooklyn 220kV","Brunswick 220kV","Bulgana WF","Bundamba (T162) 110kV","Bungama 132kV","Bunnerong 132kV","Burnie","Burnside 66kV","Buronga 220kV","Burrinjuck 132kV","Butlers Gorge Tee","CAPE RIVER EAST","CHARTERS TOWERS","Cairns North 132kv","Callide 132kV","Calliope River (H067)","Camellia 132kV","Campbell St","Campbelltown 66kV","Camperdown 66kV","Canberra 330kV","Canowie","Canterbury 132kV","Capital Wind Farm 330kV","Capral 132kV","Carwarp CPTS","Catagunya","Cethana","Chapel Street","Charmhaven 132kV","Cheltenham 66kV","Cherry Gardens 275kV","Chltnm/croy_p/croydn 66kV Tee","Chullora 132kV","City West","Clare North","Clare South 132kV","Clarence Gardens 66kV","Clarendon 66kV","Clearview 66kV","Clements Gap Wind Fram","Clermont_SF","Clover Ps 66kV","Cluny","Coffs Harbour 330kV","Colac 66kV","Coleambally 132kV","Collector Wind Farm 330kV.","Collinsville North","Colongra","Colongra Power Station","Columboola 132kV (T194)","Columboola H077","Comalco","Condabri Central (T217)","Condamine Power Station (T200)","Cooma 132kV","Coomera 110kV","Coopers Gap","Coopers Gas WF","Cooran","Coorong SF","Coorong2 SF","Coromandel Pl 66kV","Corowa 132kV","Cowra 132kV","Cranbourne 220kV","Creek Road","Cressy 500 kV Station","Cronulla 132kV","Crowlands","Crowlands WF","Croydon 66kV","Croydon Park 66kV","Croytee/n_adel/hind_s 66kV Tee","Crudine Ridge WF","Cudmore Park 66kV","Culcairn SF 330kV Station","Cullerin Range 132kV","Cultana 275kV","Cultana East 275kV","DINAWAN 330kV Switching Station","Daandine 110kV","Dalrymple","Dapto 330kV","Darling Downs PS 275KV","Darling Downs SF","Darlington Point 330kV","Dartmouth Ps 220kV","Davenport 275kV","Dederang 330kV","Deniliquin 132kV","Derby","Derwent Bridge","Devils Gate","Devonport","Directlink-QLD ","Dorrien 132kV","Drillham","Dry Creek 66kV","Dry_ck/kilb_s/prosp 66kV Tee","Duaringa (T210)","Dubbo 132 substation","Dubbo South substation","Dubbo West substation","Dulacca Wind Farm","Dunoon 132kV","EUROA 275KV","East Lismore 66/11kV","East Rowville 220kV","East Terrace 275kV","Eastlakes 132kV","Edinburgh 66kV","Eildon Ps 220kV","El Arish 132KV","Elaine 220kV","Electrona","Elizabeth Downs 66kV","Elizabeth Heights 66kV","Elizabeth South 66kV","Emerald West Tee Station","Emeroo","Emu Bay","Eraring 500kV","Evanston 66kV","Ewingsdale 66/11kV","FORBES 132kV","Farrell","Findon 66kV","Finley 132kV","Fisher","Fishermans Bend 220kV","Flinders Park 66kV","Forbes 132kV","Fulham Gardens 66kV","GEURIE 132kV Station","Gadara 132kV","Gatton (SSGBS) 110kV","Geelong 220kV","George Town","George Town Converter Station","Gladstone North (T074)","Gladstone South (T152) 132kV","Glanville 66kV","Glen Innes 132kV","Glenelg North 66kV","Glenrowan 220kV","Glenrowan West Solar Farm","Golden Grove 66kV","Goodna (H38)","Goorambat East GETS Station","Gordon","Gosford 132kV","Goulburn 132kV","Goyder South Wind Farm","Granite Creek 132kV","Green Square","Greenbank (S003)","Griffin 110kV","Griffith 132kV","Guildford 132kV","Gullen Range 330kV WF","Gunnedah","Gunnedah SF","Gunning Wind Farm","Guthega","Guybal Munjan 275 kV","H092 K2H Kidston Hydro Station","H098 Wambo Windfarm","H108 TUMOULIN","H114 WAMBO WIND FARM 2","H125 JUANDAH","H126 MURANU","H139 STANWELL BESS","H146 Edenvale Solar Substation","H162 BANANA BRIDGE","H53 Kogan Creek PS Switchyard","H63 Teebar Creek","HALHIL","HALLET WINDFARM","HILLSTON","HUGH","Hadspen","Hallet Hill Wind Farm","Hallet Ps","Halys (S2)","Hampshire","Happy Valley 275kV","Harrow 66kV","Haunted Gully TS 500kV","Haymarket 330kV","Hazelwood 500kV","Hazelwood Ps 220kV","Heatherton 220kV","Henley South 66kV","Heywood 500kV","Hillcrest 66kV","Hindley St 66kV","Holden Hill 66kV","Holroyd 330kV","Homebush Bay 132kV","Hornsdale WF","Hornsdale WF 1","Horsham 220kV","Hume Ps 132kV","Hummocks 132kV","Hvewme 66kV","Hwps/mwts/mps 220kV Tee","Ingham South 132kV","Ingle Farm 66kV","Ingleburn 330kV","Inverell 132kV","JARDINE RIVER","JUNEE SOLAR FARM","Jeeralang 220kV","Jeeralang A Ps 220kV","Jeeralang B Ps 220kV","Jindabyn Ps","Jinderra 330kV","John Butters","John Lysaght Aust. 220kV","Junee Station","KENNEDY ENERGY PARK","Kaban Wind Farm","Kadina_East 132kV","Kangaroo Valley Ps","Kanmantoo Mine","Keilor 220kV REACT","Keilor 500kV","Keith 132kV","Kemps Creek 500kV","Kempsey 132kV Sub","Kent_t 66kV","Kerang 220kV","Kermandie","Keswic/n_rich/plympt 66kV Tee","Keswick 66kV","Kiamal SF","Kilburn 275kV","Kilburn South 66kV","Kilkenny 66kV","Kincraig 132kV","King Creek (T177) 132kV","Kingston","Kingswood 66kV","Knights Road","Koolkhan 132kV","Koorangie 220 kV Station","Korenan 132kV","Kumarilla Park (H75)","Kurnell 132kV","Kurri 132/11kV","Kurri 132kV","Kurri 132kV eA","Ladbroke Grove 132kV","Lake Bonney Wind Farm","Lake Echo","Lake Ross","Lakeland","Lane Cove 132kV","Larcom Creek (H58)","Largs North","Laverton North 66kV","Lawson 132kV","Lefevre 66kV","Lemonthyme","Lennox Head 66/11kV","Liapootah","Liddell BESS","Liddell Ps 330kV","Lincoln Gap WF","Linden Park","Lindisfarne","Lismore 132kV","Lismore 330kV","Lismore 66kV","Liverpool 330kV","Louisa Creek","Lower Mitchem 66kV","Lower Tumut","Loy Yang 66kV","Loy Yang A Ps 500kV","Loy Yang B Ps 500kV","Loy Yang Gas","Loy Yang Ps 500kV","MACARTHUR WF","MANILDRA 132kV","MISS 330KV","MYRTLETOWN 110KV","Macarthur 330kV","Macintyre North 330kV","Mackay Ports","Mackintosh","Macksville 132kV","Macquarie Park 132kV","Magill 275kV","Magill/uraidl/linpkt 66kV Tee","Malvern 220kV","Mamre 132kV IE","Mannum","Mannum-adelaide 1","Mannum-adelaide 2","Mannum-adelaide 3","Maroubra 132kV","MarrickVille 132kv","Marulan 330kV","Maryrorough SF","Maryvale Solar Farm & BESS","Mason Park 132kV","Mayura 132kV","Mckay Creek Ps 220kV","Mclaren Flat","Meadowbank","Meadowbank 132kV","Memooloo","Merrimac","Metz Solar Farm132/33kV","Metz_SF","Midback 132kV","Millbr 132kV","Mintaro 132kV","Mitchell 132kV","Mobilong 132kV","Mokota","Molendinar (H31) 275kV ","Molong 132kV","Monash 132kV","Moorabool 500kV","Moranbah 132kV","Moree 132kV Substation","Mornington","Morp_e:mc_l_f:willun 66kV Tee","Morphett Vale East 275kV","Morphettville 66kV","Mortlake Power Station","Mortlake Sth WF","Morwell 220kV","Morwell Ps 66kV","Mount Barker South","Mount Lock 275kV","Mount Piper 330kV","Mount Piper 500kV","Mount Stuart Ps","Moura 132kV","Mowbray","Mt Barker 132kV","Mt Beauty 220kV","Mt Druit 132kV","Mt Gambier 132kV","Mt Gunson 132kV","Mt Mclaren 132kV","Mt Millar 132kV","Mt. England 275kV","Mudgeeraba 275kV","Mullumbimby 132kV (northpower)","Mulwala 132kV","Mungar 132kV","Munmorah 330kV","Munmorah/sydnth/tuggerah 330kV Tee","Munyang 132kV","Murarrie 110kV","Murra Warra","Murray","Murray Bridge-hahndorf 1","Murray Bridge-hahndorf 2","Murray Bridge-hahndorf 3","Murraylink Vic","Murraylink-SA","Murrumburrah 132kV","Muswellbrook 132kV","Muswellbrook 330kV","Mwps1 132kV","Mwps2 132kV","Mwps3 132kV","Mwps4 132kV","Myrtleford 66kV","NARRANDERA","NDSC-North","NRCS","N_unly/whit_s/keswic 66kV Tee","Nambour 132kV","Nambucca 132kV","Narrabri 132kV Substation","Narromine South substation","Nebo 275kV","Nepean 132kV","Nerang 110kV","Neuroo 132kV","Nevertire 132kV","Nevertire substation","New England Solar Farm","New Norfolk","New Osborne 66kV","New Richmond 66kV","New Tennyson 110kV","Newcastle 330kV","Newlands 132kV","Newport D Ps 220kV","Newstead   110kV","Newton","Noarlunga Centre 66kV","North Adelaide 66kV","North Brown Hill Wind Farm","North Goonyalla Mine 132kV","North Hobart","North Unley 66kV","North West Bend 132kV","Northern Ps 275kV","Northfield 275kV","Norwich Park 132kV","Norwood","Norwood 66kV","Nudgee 110kV","Nyngan 132kV","Nyngan Solar Farm","Oakey 110kV (T189)","Oakey Power Station","Oakey SF","Oaklands 66kV","Olympic Dam North 132kV","Olympic Dam West 275kV","Oonooie 132kV","Orana (H78)","Orana BESS 330kV","Orange 132kV","Orange North 132kV","Osborne Cogen Plant","Ourimbah 132kV","PT_PATERSON_N","Palmerston","Palmwoods 275kV","Paloona","Pandoin 132kV","Panorama 132kV","Panorama 66kV","Para 275kV","Parafield Gardens 66kV","Parafield Gardens West 275kV","Paralowie 66kV","Parkes 132kV","Peak Downs 132kV","Peakhurst 132kV","Pelican Point Switching station","Pelican Point ps","Penfield 66kV","Penola West","Penrith 132kV","Pialba","Pieman","Pimba 132kV","Pioneer Valley 132kV","Play:mt_gun:pimba 132kV Tee","Playford A + B Ps 275kV","Plumpton 500 kV","Plympton 66kV","Poatina","Point Henry 220kV","Point Noarlunga 66kV","Point Stanvac 66kV","Porcupine Range Wind Farm","Port Latta","Port Lincoln 132kV","Port Macquarie 132kV","Port Pirie 132kV","Port Pirie 33kV","Postmans Ridge (SST29) 110kV","Prominent Hill","Proserpine 132kV","Prosp/nadeltee/croydn 66kV Tee","Prospect 66kV","Pt Adelaide  66kV","Pt Adelaide Nth 66kV","Pwpst_t 132kV","QR Mindi (T172)","QUEANBEYAN 132kV","Qal  (qld. Aluminium) 132kV","Quarantine Ps","Que","Queensland Alumina South","Queensland Alumina West","Queenstown","Queenstown 66kV","Quorn Park Solar Farm","R5 Millmeran Ps","Raglan (H73)","Railton","Raleigh 132kV","Ravine","Red Cliffs 220kV","Redbank 132kV","Redbank Plains 110kV","Redhill","Reece","Reedy Creek","Regentville 330kV","Repulse","Richlands 110kV","Richmond 220kV","Ringwood 220kV","Risdon","Riverina132kV Substation","Robertstown 275kV","Robina 110kV","Rockhampton 132kV","Rocklands 132kV","Rocklea 275kV","Rocky Point","Rokeby","Rollston 132kV","Roma 132kV","Roma Power Station","Rookwood Road 330kV","Rosebery","Roseworthy 132kV","Ross 275kV","Rothbury 132kV Substation","Rowallen","Rowville 220kV","Rowville 500kV","Rubicon A 66kV","Rugby Run Solar Farm","Runcorn 110kV","Rye Park Wind Farm North","Rye Park Wind Farm South","S5 Western Downs","SEBASTOPOL SOLAR","SNAPPER POINT GENERATOR SWITCHYARD","SRCS","Salisbury 66kV","Sapphire 330kV","Savage River","Scottsdale","Seacombe 66kV","Sheffield","Sheidow Park 66kV","Shepparton 220kV","Singleton 132kV","Sleaford","Smithton","Snowtown","Snowtown Nth","Snowtown South 275kV","Snowtown Sth","Snowy","Snuggery 132kV","Somersby 132kV","Somerton Ps","Somerton Sw 66kV","Sorell","South East 275kV","South Lismore 66kV","South Morang 500kV","South Pine 275kV","South Toowoomba 110kV","Southport","Spring Hill","Springvale 220kV","Ssrvw","St Marys","St Peters 132kV","Stafford 110kV","Stanthorpe 110kV","Stanwell 275kV","Stanwell 66kV","Stanwell Ps","Stanwell Ps Aux","Starwood","Steeple Flat","Stockdill","Stoney Creek (T178)","Stony Point 132kV","Strathmore 275kV","Stroud 132kV","Stubbo 330kV station","Studland Bay Wind Farm","Summer Field BESS 1","Summer Field BESS 2","Sumner (T160) 110kV","Sunraysia SF","Suntop SF","Supernode BESS (H154)","Surfers Paradise","Swanbank A 110kV","Swanbank A PS","Swanbank B 275kV","Swanbank B PS","Swanbank C 275kV","Swanbank D Ps","Swanbank E Ps","Syd-Nth/Syd-East/Somersby 132kV Tee","Sydenham 500kV","Sydney East 330kV","Sydney North 330kV","Sydney South 330kV","Sydney West 330kV","T129 Edmonton","T146_oakey","T254 BANANA","T256 GREENLAND 1","T257_FRI IRONBARK 13","T271 Wandoan South Bess","T285 MUNNA CREEK","T293 WOOLOOGA BESS","TEMORA","TULLY SOUTH 275KV","TUMMAVILLE 330KV","Tailem Bend 275kV","Tallawarra","Tamar Valley PS","Tamworth 330kV","Tangkam 110kV","Taralga WF","Taree 132kV","Tarong 275kV","Tarong North  Ps","Tarong Ps","Tarraleah","Tarrone 500kV","Tea Tree Gully 66kV","Temco","Templers 132kV","Templers West","Templestowe 220kV","Tennyson (T142) 110kV","Tenterfield 132kV","Terang 220kV","Terranora 110kV","Thebarton 66kV","Thomastown 220kV","Tie Dav-pla 132kV","Tips_a/p_ad_n/athol 66kV","Tips_a:ti_n  :qps    66kV Tee","Tomago 132kV","Tomago 330kV","Tonsley Park 66kV","Torrens A Ps 275kV","Torrens B Ps 275kV","Torrens Island BESS","Torrens North","Torrington (T116)","Townsville 132kV","Townsville East 132kV","Townsville Gt Ps","Townsville South 132kV","Townsville Zinc","Toyota 66kV","Traveston 132kV","Trevallyn","Triabunna","Tribute","Tuggerah 330kV","Tully 132kV","Tumut 132kV","Tungatinah","Tungkillo","Turkinje 132kV","Tyabb 220kV","URALLA 330kV","UUNGULA 330kV SWITCHING STATION","UUNGULA 330kV WIND FARM","Ulverstone","Upper Tumut","Uraidl 66kV","Uraidt/lin_pk/panora 66kV Tee","Uranquinty 132kV","VBB","Vales Point 330kV","Victoria Park 110kV","Vineyard 330kV","Virginia Control Centre","WIDGEE CREEK","WPD","Waddamana","Wagga 132kV","Wagga 330kV","Wagga North 132kV","Walla Walla 330kV","Wallerawang Ps 330kV","Wandoan South (H76)","Wangaratta 66kV","Waratah Tee","Waratah West ","Warragamba Power Station ","Warrimoo 132kV","Warwick 110kV","Waterloo 132kV","Waterloo East","Waterloo Wind Farm","Wattle Point Windfarm","Waubra 220kV","Wayatinah","Wayatinah Tee","Wellington 330kV","Wellington North SF","Wellington Rd 110kV","Wellington/piper/orange 132kV Tee","Wemen 220kV","Wesley Vale","West Darra 110kV","West End 110kV","West Gosford 132kV","West Jemalong","West Kiewa Ps 220kV","West Liverpool 132kV","West Melbourne 220kV","West Wetherill Park 132kV","Wetherill Park 132kV","Whitmore Square 66kV","Whyalla Central","Whyalla Terminal 132kV","Williamsdale 330kV","Willunga 66kV","Wilmot","Winchelsea 66kV","Winton Solar Farm","Wivenhoe Ps","Wodonga 330kV","Woleebee Creek","Wollar 500kV","Wollar West 330kV Substation","Woodforde 66kV","Woodstock","Woodville 66kV","Woolooga 275kV","Woomera 132kV","Woree 275kV","Woreen BESS","Wotonga (T221)","Wurdong 275kV","Wyalong Solar Farm","Wycarbah (T211)","Wyong 132kV","Yabulu South (H56)","Yadnarie 132kV","Yalkula","Yallourn  Ps 220kV","Yanco 132kV","Yarranlea 110kV","Yarwun (T199)","Yass 330kV","Yatala","Yendon Windfarm","Z035 CHINCHILLA BESS STATION","Z13_BOULDERCOMBE BESS","Z34 BLUE GRASS SOLAR FARM","west wyalong sol"]},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The time that this record was last changed.","examples":["2003/04/28 16:51:18.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"OWNERID":{"sql_type":"VARCHAR(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"The TNSP who is responsible for this substation","examples":["AEMO","APT","AusNet","ElectraNet","Endeavour E","Essential E","Powerlink","TOA","TasNetworks","Transgrid"],"is_categorical":true},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The NEM region the substation is in","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VALIDTO":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"The record is valid up until this date (exclusive)","examples":["2004/09/28 08:18:11.000"],"parse_csv_as_string":true,"is_ms_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23NETWORK_SUBSTATIONDETAIL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":29319,"decompressed_size_all_time":6660280},"visibility":"Public","trigger":"When subtation details are created or added"},"OARTRACK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#746"],"comment":"OARTRACK shows an audit trail of bids for a particular settlement day. Corrupt bids do not update OARTRACK, but are just in OFFERFILETRK.","description":"Not in Use - discontinued 16/11/2003\n\nStatus\n\nThe OARTRACK table is obsolete. Please refer to BIDOFFERFILETRK. As a\ntransition assist, the OARTRACK views expose data based on\nBIDOFFERFILETRK.\n\nSource\n\nOwn (confidential) data updates as bids are processed. All bids are\navailable as part of next day market data.","unused":true,"primary_keys":["OFFERDATE","PARTICIPANTID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date file offered","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no for this offer date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Load file name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private & Public Next-Day"},"OFFERAGCDATA":{"package":"ASOFFER","pdr_config":{"mappings":[{"REPORT_NAME":"ASOFFER","REPORT_SUB_TYPE":"OFFERAGCDATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.htm#1"],"comment":"OFFERAGCDATA shows availability reoffers of Automatic Generation Control.","description":"OFFERAGCDATA data is confidential to the relevant participant.\n\nSource\n\nOFFERAGCDATA updates as reoffers submitted.","primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date of offer","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AGCDOWN":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"AGC Ramp Rate Down. This is used by SPD.","is_integer":true,"num_int_bits":16},"AGCUP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"AGC Ramp Rate Up. This is used by SPD.","is_integer":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABILITY":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Availability flag (0 or 1)","is_boolean":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Name of reoffer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERLIMIT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower control limit MW. This is used by SPD.","is_integer":true,"num_int_bits":16},"UPPERLIMIT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Upper control limit. This is used by SPD.","is_integer":true,"num_int_bits":16}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"On participant Automatic Generation Control (AGC) reoffers submission"},"OFFERASTRK":{"package":"ASOFFER","pdr_config":{"mappings":[{"REPORT_NAME":"ASOFFER","REPORT_SUB_TYPE":"OFFERASTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.htm#12"],"comment":"OFFERASTRK tracks successfully acknowledged ancillary service reoffers.","description":"OFFERASTRK data is confidential to the relevant participant.\n\nSource\n\nOFFERASTRK is updated as offers are successfully acknowledged.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market day starting at 4:00 am","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant ID","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of the offer for that date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Submitted file name."},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date and time.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When ancillary service reoffers are successfully acknowledged"},"OFFERFILETRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#757"],"comment":"OFFERFILETRK shows an audit trail of all bid files submitted containing energy bids, including corrupt bids/rebids.","description":"Status\n\nOFFERFILETRK is obsolete. Please see BIDOFFERFILETRK.\n\nSource\n\nOFFERFILETRK is obsolete.","unused":true,"primary_keys":["FILENAME","OFFERDATE","PARTICIPANTID"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":true,"comment":"Load file name"},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date file offered","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"ACKFILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Acknowledge file name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Load status [SUCCESSFUL/CORRUPT]"},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"As bids are processed"},"OFFERGOVDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#768"],"comment":"OFFERGOVDATA sets out reoffers of governor (6 and 60 second FCAS) availability.","description":"Not in Use - discontinued 30/09/2001\n\nConfidential to participant\n\nSource\n\nUpdated as reoffers process.","unused":true,"primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Version No.","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date of Re-Offer","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No. of Re-Offer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"File name of Re-Offer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SEC6AVAILDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability for 6 Second Lower (0 or 1)","is_integer":true,"num_int_bits":32},"SEC6AVAILUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability for 6 Second Raise (0 or 1. '0'= unavailable, '1' = available)","is_integer":true,"num_int_bits":32},"SEC60AVAILDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability for 60 Second Lower (0 or 1)","is_integer":true,"num_int_bits":32},"SEC60AVAILUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability for 60 Second Raise (0 or 1)","is_integer":true,"num_int_bits":32}},"visibility":"Private","trigger":"Updated as reoffers are processed"},"OFFERLSHEDDATA":{"package":"ASOFFER","pdr_config":{"mappings":[{"REPORT_NAME":"ASOFFER","REPORT_SUB_TYPE":"OFFERLSHEDDATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.htm#21"],"comment":"OFFERLSHEDDATA shows reoffers of load shed including available load shed quantity. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"OFFERLSHEDDATA data is confidential to the relevant participant.\n\nSource\n\nOFFERLSHEDDATA updates as reoffers process.","primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date of reoffer","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of reoffer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABLELOAD":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Available load","is_integer":true,"num_int_bits":16},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Name of reoffer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On participant reoffers submission"},"OFFERRESTARTDATA":{"package":"ASOFFER","pdr_config":{"mappings":[{"REPORT_NAME":"ASOFFER","REPORT_SUB_TYPE":"OFFERRESTARTDATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.htm#30"],"comment":"OFFERRESTARTDATA sets out reoffers of system restart availability.","description":"OFFERRESTARTDATA data is confidential to the relevant participant.\n\nSource\n\nOFFERRESTARTDATA updates as reoffers process.","primary_keys":["CONTRACTID","OFFERDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract identifier","is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of contract","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABILITY":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":false,"comment":"Available load"},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Name of reoffer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On system restart availability reoffers"},"OFFERRPOWERDATA":{"package":"ASOFFER","pdr_config":{"mappings":[{"REPORT_NAME":"ASOFFER","REPORT_SUB_TYPE":"OFFERRPOWERDATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.htm#39"],"comment":"OFFERRPOWERDATA shows reoffers of reactive power capability and settlement measurements. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"OFFERRPOWERDATA data is confidential to the relevant participant.\n\nSource\n\nOFFERRPOWERDATA updates as reoffers process.","primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Version No.","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Contract Version No.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market trading interval","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No. of Re-Offer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User Name"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Contract was Authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABILITY":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Availability of service","is_integer":true,"num_int_bits":16},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"File name of Re-Offer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MTA":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Reactive Power Absorption Capability (MVar)","is_integer":true,"num_int_bits":32},"MTG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Reactive Power Generation Capability (MVar)","is_integer":true,"num_int_bits":32}},"visibility":"Private","trigger":"On reactive power capability and settlement measurements reoffers submission"},"OFFERULOADINGDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#779"],"comment":"OFFERULOADINGDATA shows reoffers of rapid unit loading capability.","description":"Not in Use - discontinued 30/09/2001\n\nOFFERULOADINGDATA data is confidential to each participant.\n\nSource\n\nOFFERULOADINGDATA updated as reoffers processed.","unused":true,"primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of contract","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABLELOAD":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Available load","is_integer":true,"num_int_bits":16},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Name of reoffer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated as reoffers are processed"},"OFFERUNLOADINGDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#790"],"comment":"OFFERUNLOADINGDATA shows reoffers of rapid unit unloading capability.","description":"Not in Use - discontinued 30/09/2001\n\nOFFERUNLOADINGDATA data is confidential to the relevant participant.\n\nSource\n\nOFFERUNLOADINGDATA updates as reoffers processed.","unused":true,"primary_keys":["CONTRACTID","EFFECTIVEDATE","PERIODID","VERSIONNO"],"indexes":[["LASTCHANGED"],["CONTRACTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date of reoffer","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Market day trading interval number","is_integer":true,"num_int_bits":16},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of reoffer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorised by"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABLELOAD":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Available load","is_integer":true,"num_int_bits":16},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Name of reoffer file"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated as reoffers are processed"},"OVERRIDERRP":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"FORCE_MAJEURE","REPORT_SUB_TYPE":"OVERRIDERRP","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#62"],"comment":"OVERRIDERRP shows details of override price periods.","description":"OVERRIDERRP data is public, so is available to all participants.\n\nSource\n\nOVERRIDERRP updates every five minutes when override prices apply for\nthe period.","primary_keys":["REGIONID","STARTDATE","STARTPERIOD"],"indexes":[["LASTCHANGED"]],"columns":{"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"NSW1\", \"VIC1\", \"SA1\", \"TAS1\", \"ALL\"])","mandatory":true,"comment":"Region Identifier","examples":null,"warnings":["Unlike most tables, this column may contain the value `ALL`, if the override applies to all regions at once."],"enums":["QLD1","NSW1","VIC1","SA1","TAS1","ALL"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Starting date of override","examples":["1998/10/29 10:10:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Starting period of override","examples":["35","280"],"is_integer":true,"num_int_bits":16},"AUTHORISEEND":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorise End of Override","examples":["ALANH","BATCH","BFLEMING","BWEBB","BWOOD","CBROWNLEE","CHERDEN","IGNAZIOR","JAMESH","PHILIPS","PRYAN","TOM"]},"AUTHORISESTART":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorise Start of Override","examples":["ALANH","BATCH","BFLEMING","BWEBB","BWOOD","CBROWNLEE","CHERDEN","IGNAZIOR","JAMESH","PHILIPS","PRYAN","TOM"]},"DESCRIPTION":{"sql_type":"VARCHAR2(128)","pl_type":"str","mandatory":false,"comment":"Description of reason for override","examples":["Bob Rigoni testing","Demand reduction due to maximum supportable demand and violating interconnector limits","Directed load shed in Victoria","Directed load shedding in VIC ","Involentary load shedding","Involuntary Load Shedding VIC","Involuntary Load Shedding in SA ","Involuntary load shedding SA Region","J Petteit testing","John Petteit testing","Load Shedding WED 8TH FEB 2017 SA ","Load shed in South Australia region, island formation","Load shedding Tomago Potline","Pain Sharing in SA violating interconnector limitts","SA involuntary load shedding restored","Shedding load in Victoria due to multiple 500kV feeder outage. ","VOLL = SA1","Violating Interconnector constraints","Violating interconnector constraints.","Voll override Sa Seperation Event 11-Mar-05.","VtoSA interconnection broken, involuntary load shed in SA","directed wivenhoe pump 2 to off. unable to maintain hz.","involuntary load shedding Vic region (3/2/2000)","loss of load","testing","vic/sa/nsw separation 16th Jan 2007"]},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Termination date of override","examples":["1998/10/29 10:15:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Terminate period of override","examples":["36","282"],"is_integer":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/10/29 10:07:19"],"parse_csv_as_string":true,"is_s_datetime":true},"RRP":{"sql_type":"NUMBER(15,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Dispatch Price","examples":["5000","16600"],"is_integer":true,"num_int_bits":64}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23OVERRIDERRP%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1671,"decompressed_size_all_time":2174650},"visibility":"Public","trigger":"Every five minutes when override prices apply for the period."},"P5MIN_BLOCKEDCONSTRAINT":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"BLOCKED_CONSTRAINTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#1"],"comment":"P5MIN Blocked Constraints lists any constraints that were blocked in a P5MIN run. If no constraints are blocked, there will be no rows for that 5 minute predispatch run.","primary_keys":["CONSTRAINTID","RUN_DATETIME"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint identifier (synonymous with GenConID)","examples":["#R036712_001_RAMP_F","#R036712_001_RAMP_V","#R036733_002_RAMP_F","#R036733_002_RAMP_V","#R036760_001_RAMP_F","#R036760_001_RAMP_V","#R036761_001_RAMP_F","#R036761_001_RAMP_V"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"5-minute Predispatch Run","examples":["2026/09/01 00:10:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_BLOCKEDCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":9},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":637,"decompressed_size_all_time":283640},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_CASESOLUTION":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#7"],"comment":"The five-minute predispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The 5-minute Predispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_CASESOLUTION shows one record containing results pertaining to the entire solution.","description":"P5MIN_CASESOLUTION data is public, so is available to all participants.\n\nSource\n\nP5MIN_CASESOLUTION updates every 5 minutes.\n\nVolume\n\nRows per day: 288","primary_keys":["RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run. This field has a default value of 0 and is not nullable","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_CASESOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date and time of this record","examples":["2026/09/01 00:00:33"],"parse_csv_as_string":true,"is_s_datetime":true},"NONPHYSICALLOSSES":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate non-physical losses occurred in this study","examples":["0"],"is_boolean":true},"STARTINTERVAL_DATETIME":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Date and Time of first interval in study","examples":["2026/09/01 00:05:00"]},"TOTAL5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of regional 5 min FCAS violations","is_float":true},"TOTAL6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of regional 6 sec FCAS violations","is_float":true},"TOTAL60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of regional 60 sec FCAS violations","is_float":true},"TOTALAREAGENVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Regional Energy balance violations","examples":["0"],"is_float":true},"TOTALASPROFILEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of unit FCAS profile offer violations","examples":["0"],"is_float":true},"TOTALENERGYCONSTRVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of unit energy constrained violations","examples":["0"],"is_float":true},"TOTALENERGYOFFERVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of unit offer violations","examples":["0"],"is_float":true},"TOTALFASTSTARTVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of unit Fast start profile violations","examples":["0"],"is_float":true},"TOTALGENERICVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Generic Constraint violations","examples":["0.001","0","2","360"],"is_float":true},"TOTALINTERCONNECTORVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Interconnector violations of standing data limits","examples":["0"],"is_float":true},"TOTALOBJECTIVE":{"sql_type":"NUMBER(27,10)","pl_type":"pl.Float64","mandatory":false,"comment":"The Objective function from the LP","examples":["-6205670.672","1855962.533","-904098896.997","97640236986.66"],"is_float":true},"TOTALRAMPRATEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Unit Ramp Rate violations","examples":["0.025","0","0.79"],"is_float":true},"TOTALREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of regional regulation FCAS violations","is_float":true},"TOTALUNITMWCAPACITYVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of unit capacity violations","examples":["0.36","0","2","580"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":191031,"decompressed_size_all_time":257657030},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_CONSTRAINTSOLUTION":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#16"],"comment":"The Five-Minute Pre-Dispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The Five-Minute Pre-dispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.","description":"P5MIN_CONSTRAINTSOLUTION is public data, so is available to all\nparticipants.\n\nSource\n\nP5MIN_CONSTRAINTSOLUTION updates every five minutes.\n\nVolume\n\nRows per day: ~2.3 million","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["DATASNAP_DFS_QSTHE","DATASNAP_DFS_QSTHW","DATASNAP_DFS_Q_BCCP","DATASNAP_DFS_Q_BCRG","DATASNAP_DFS_Q_CLST","DATASNAP_DFS_Q_CLWU","DATASNAP_DFS_Q_LCCP","DATASNAP_DFS_Q_RGLC","DATASNAP_DFS_Q_TAMR","DATASNAP_DFS_Q_TAMR2","DATASNAP_DFS_SADL","DATASNAP_DFS_SNTH","DATASNAP_DFS_SRIV","DATASNAP_DFS_SSE","DATASNAP_DFS_SWNSW","DATASNAP_DFS_TNTH","DATASNAP_DFS_TNWEST","DATASNAP_DFS_TWCST","DATASNAP_DFS_T_FASH1","DATASNAP_DFS_T_GOCS1","DATASNAP_DFS_T_HAGT1","DATASNAP_DFS_T_PMHA1","DATASNAP_DFS_T_PMHA3","DATASNAP_DFS_T_SHGT","DATASNAP_DFS_T_SHPM","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/24 00:25:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/24 00:25:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"DUID to which the Constraint is confidential. Null denotes non-confidential","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"name_in_csv":"CONFIDENTIAL_TO","is_categorical":true},"GENCONID_EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Effective date of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["2013/08/21 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID_VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Version number of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["1","2"],"is_integer":true,"num_int_bits":128},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run(INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0)","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_CONSTRAINTSOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/24 00:20:31"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregation of the constraints LHS term solution values","examples":["-0.45381","5.21261","170","1276.87673"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of constraint (>0 if binding)","examples":["0"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Right Hand Side value in the capacity evaluation","examples":["-0.00032","20.49098","-630","10732"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of Violation (>0 if violating)","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_CONSTRAINTSOLUTION%23FILE03%23202609010000.zip","manifest_summary":{"max_files_per_month":4,"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1216690401,"decompressed_size_all_time":1280564414150},"visibility":"Private & Public","trigger":"Every 5 minutes"},"P5MIN_FCAS_REQUIREMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#801"],"comment":"5-minute Predispatch constraint tracking for Regional FCAS recovery","unused":true,"primary_keys":["BIDTYPE","CONSTRAINTID","INTERVAL_DATETIME","REGIONID","RUN_DATETIME"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"ConstraintID Join to table GenConData","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime of the 5-minute Predispatch interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"First interval of the 5-minute Predispatch case","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, after the regulation/contingency split","is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint for this service, before the regulation/contingency split","is_float":true},"CONSTRAINT_EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Constraint EffectiveDate Join to table GenConData","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONSTRAINT_VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Constraint Version number Join to table GenConData","is_integer":true,"num_int_bits":16},"ESTIMATED_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CMPF, based on 5- minute Predispatch data","is_float":true},"ESTIMATED_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CRMPF, based on 5-minute Predispatch data","is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Intervention flag","warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_FCAS_REQUIREMENT."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for energy","is_float":true},"RECOVERY_FACTOR_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery factor for CMPF based recovery","is_float":true},"RECOVERY_FACTOR_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery for CRMPF based recovery","is_float":true}},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_FCAS_REQ_CONSTRAINT":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"FCAS_REQ_CONSTRAINT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#25"],"comment":"The constraint level FCAS cost / price details for constraint FCAS processor runs. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["BIDTYPE","CONSTRAINTID","INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNNO"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"ConstraintID join to table GenConData","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_TL_L1_DS","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_BLSPS_L5","F_T++NIL_BLSPS_L6","F_T++NIL_BLSPS_L60","F_T++NIL_BLSPS_R5","F_T++NIL_BLSPS_R6","F_T++NIL_BLSPS_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_TL_L5_DS","F_T++NIL_TL_L60_DS","F_T++NIL_TL_L6_DS","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_TL_L5_DS","F_T+NIL_TL_L60_DS","F_T+NIL_TL_L6_DS","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The 5 minute interval date and time of the 5 minute predispatch interval that was processed by the constraint FCAS processor","examples":["2026/09/16 11:25:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 5 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026/09/16 11:20:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 5 minute predispatch case run number that has triggers the constraint FCAS processor run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, after the regulation/contingency split","examples":["0.2375","0","36.40833333"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint, before the regulation/contingency split","examples":["0.2375","0","36.40833333"],"is_float":true},"CONSTRAINT_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW enabled for this bid type within the constraint","examples":["31.28","0","12","285"],"is_float":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints summed LHS - aggregate LHS Solution values from the physical run from the P5MIN_CONSTRAINTSOLUTION table","examples":["-11.02678","0.685","0","220"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Shadow price of constraint from the P5MIN_CONSTRAINTSOLUTION table from the physical run.","examples":["0.01","0","3.79"],"is_float":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted marginal value of the constraint for FPP recovery (blank for constraints without REG terms)","examples":["0.01","0","3.79"],"is_float":true},"REGION_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The regional payment allocated to the constraint for the interval pro- rated based on marginal value ratios over the binding constraints for that service in that region (this is an intermediate calculation to get to the base cost)","examples":["0.01","0","15.79166667"],"is_float":true},"REGIONAL_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The dispatched MW for the bid type inside the region from the physical run of the P5MIN_REGIONSOLUTION table","examples":["29.67","0","3","190"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints RHS value used in the solution - may be either dynamic (calculated) or static from the physical run from the P5MIN_CONSTRAINTSOLUTION table","examples":["-8.12571","5.49538","0","1390"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Bid type prices for the region coming from the pricing run of the P5MIN_REGIONSOLUTION table","examples":["0.01","0","3.8"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_FCAS_REQ_CONSTRAINT%23FILE02%23202609010000.zip","manifest_summary":{"max_files_per_month":33,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":753121690,"decompressed_size_all_time":1414986532630},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a 5 minute predispatch run"},"P5MIN_FCAS_REQ_RUN":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"FCAS_REQ_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#31"],"comment":"The constraint FCAS processor run details. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["RUN_DATETIME","RUNNO"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 5 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 5 minute predispatch case run number that has triggers the constraint FCAS processor run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last time the constraint FCAS processor was executed for this case run time.","examples":["2026/09/01 00:00:40"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_FCAS_REQ_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":53341,"decompressed_size_all_time":126862060},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a 5 minute predispatch run"},"P5MIN_INTERCONNECTORSOLN":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":4}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#37"],"comment":"The five-minute predispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The 5-minute Predispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_INTERCONNECTORSOLN sets out the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","description":"P5MIN_INTERCONNECTORSOLN is public data, so is available to all\nparticipants.\n\nSource\n\nP5MIN_INTERCONNECTORSOLN updates every 5 minutes.\n\nVolume\n\nRows per day: 1440\n\nBased on 200 interconnector/binding constraints per interval","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["F_T++NIL_ML_L6","N::Q_BWMP_LDTW","NQTE_ROC","TVBL_ROC","V::N_NIL_O2","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","VSML_ZERO","V^^N_NIL_1"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-0.00001","0.39022","0","39"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-0.00001","25.58031","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-119.69971","0","-121","-2478"],"is_float":true},"IMPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++BIP_ML_L1","F_MAIN++LREG_0210","F_T++NIL_MG_R6","I_6F_SN_150","N^^V_MLNK_ARWBBA","QNTE_ROC","Q^^N_NIL_SRAR","S:V_700_HY_TEST","SVML_ZERO","T_BLINK_TV_NGZ","V::N_NIL_O2","V>>NIL_SMTX_SMTX_R5","VTBL_NIL_CONT_441","VTBL_ROC","V_T_NIL_BL1"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-14.20862","7.10995","0","-700"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0)","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_INTERCONNECTORSOLN."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:00:33"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.36","4.51","0","-49"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.31","0","26912000","15.84"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor at the cleared flow","examples":["0.78351","1.29601"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of Interconnector standing data limits (if binding)","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SCADA MW Flow measured at Run start. For periods subsequent to the first period of a P5MIN run, this value represents the cleared target for the previous period of that P5MIN run.","examples":["-0.3","0.3","0","224"],"is_float":true},"MNSP":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating MNSP registration","examples":["0"],"is_boolean":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector loading level (MW)","examples":["-14.20861","7.10994","0","-969"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector Losses at cleared flow","examples":["-0.02722","0.03335","0","184.36565"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation of Interconnector standing data limits","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":15524445,"decompressed_size_all_time":19211877440},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_INTERMITTENT_FCST_TRK":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"INTERMITTENT_FCST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#46"],"comment":"Uniquely tracks which Intermittent Generation forecast run (from INTERMITTENT_GEN_FCST_P5_RUN) was used for the DUID in which 5-Minute Pre-dispatch run.","primary_keys":["DUID","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier, tracks to INTERMITTENT_GEN_FCST_P5_RUN.DUID.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) of the 5-Minute Pre-dispatch run.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Priority of the forecast run used for the 5MPD run, tracks to INTERMITTENT_GEN_FCST_P5_RUN.FORECAST_PRIORITY.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime, unless a forecast run is missed in which case the previous run is used. Tracks to INTERMITTENT_GEN_FCST_P5_RUN.FORECAST_RUN_DATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Submission datetime of the forecast run used for the 5MPD run, tracks to INTERMITTENT_GEN_FCST_P5_RUN.OFFERDATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Provider of the forecast run used for the 5MPD run, tracks to INTERMITTENT_GEN_FCST_P5_RUN.PROVIDERID.","is_categorical":true}},"visibility":"Private & Public Next-Day","trigger":"Every 5 minutes when a new 5-Minute Pre-dispatch run is published"},"P5MIN_INTERSENSITIVITIES":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"INTERSENSITIVITIES","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#52"],"comment":"Price Sensitivies for 5MinPD solution. New solution every 5 minutes. Current Scenarios defined in P5MIN_SCENARIODEMANDTRK/P5MIN_SCENARIODEMAND","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Definitive Run from which this solution derives","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0)","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_INTERSENSITIVITIES."],"is_boolean":true},"INTERVENTION_ACTIVE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes","examples":["0"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp when this record was last modified","examples":["2026/09/01 00:01:29"],"parse_csv_as_string":true,"is_s_datetime":true},"MWFLOW1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow1 = MW flow for given Interconnector for Scenario 1","examples":["-5.66","9.6","0","-1069"],"is_float":true},"MWFLOW2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow2 = MW flow for given Interconnector for Scenario 2","examples":["-29.35","3.69","0","1043"],"is_float":true},"MWFLOW3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow3 = MW flow for given Interconnector for Scenario 3","examples":["-5.66","9.6","0","50"],"is_float":true},"MWFLOW4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow4 = MW flow for given Interconnector for Scenario 4","examples":["-10.59","2.56","0","1056"],"is_float":true},"MWFLOW5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow5 = MW flow for given Interconnector for Scenario 5","examples":["-28.28","5.25","0","1087"],"is_float":true},"MWFLOW6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow6 = MW flow for given Interconnector for Scenario 6","examples":["-3.27","2.78","0","-1003"],"is_float":true},"MWFLOW7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow7 = MW flow for given Interconnector for Scenario 7","examples":["-2.86","1.97","0","1056"],"is_float":true},"MWFLOW8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow8 = MW flow for given Interconnector for Scenario 8","examples":["-7.9","3.66","0","1056"],"is_float":true},"MWFLOW9":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow9 = MW flow for given Interconnector for Scenario 9","examples":["-12.21","5.04","0","1058"],"is_float":true},"MWFLOW10":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow10 = MW flow for given Interconnector for Scenario 10","examples":["-14.21","5.25","0","105"],"is_float":true},"MWFLOW11":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow11 = MW flow for given Interconnector for Scenario 11","examples":["-14.21","12.38","0","-1003"],"is_float":true},"MWFLOW12":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow12 = MW flow for given Interconnector for Scenario 12","examples":["-5.66","5.25","0","-833"],"is_float":true},"MWFLOW13":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow13 = MW flow for given Interconnector for Scenario 13","examples":["-14.21","7.11","0","1056"],"is_float":true},"MWFLOW14":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow14 = MW flow for given Interconnector for Scenario 14","examples":["-25.52","7.11","0","1056"],"is_float":true},"MWFLOW15":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow15 = MW flow for given Interconnector for Scenario 15","examples":["-14.21","0.43","0","1056"],"is_float":true},"MWFLOW16":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow16 = MW flow for given Interconnector for Scenario 16","examples":["0"],"is_float":true},"MWFLOW17":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow17 = MW flow for given Interconnector for Scenario 17","examples":["0"],"is_float":true},"MWFLOW18":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow18 = MW flow for given Interconnector for Scenario 18","examples":["0"],"is_float":true},"MWFLOW19":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow19 = MW flow for given Interconnector for Scenario 19","examples":["0"],"is_float":true},"MWFLOW20":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow20 = MW flow for given Interconnector for Scenario 20","examples":["0"],"is_float":true},"MWFLOW21":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow21 = MW flow for given Interconnector for Scenario 21","examples":["0"],"is_float":true},"MWFLOW22":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow22 = MW flow for given Interconnector for Scenario 22","examples":["0"],"is_float":true},"MWFLOW23":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow23 = MW flow for given Interconnector for Scenario 23","examples":["0"],"is_float":true},"MWFLOW24":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow24 = MW flow for given Interconnector for Scenario 24","examples":["0"],"is_float":true},"MWFLOW25":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow25 = MW flow for given Interconnector for Scenario 25","examples":["0"],"is_float":true},"MWFLOW26":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow26 = MW flow for given Interconnector for Scenario 26","examples":["0"],"is_float":true},"MWFLOW27":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow27 = MW flow for given Interconnector for Scenario 27","examples":["0"],"is_float":true},"MWFLOW28":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow28 = MW flow for given Interconnector for Scenario 28","examples":["0"],"is_float":true},"MWFLOW29":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow29 = MW flow for given Interconnector for Scenario 29","examples":["0"],"is_float":true},"MWFLOW30":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow30 = MW flow for given Interconnector for Scenario 30","examples":["0"],"is_float":true},"MWFLOW31":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow31 = MW flow for given Interconnector for Scenario 31","examples":["0"],"is_float":true},"MWFLOW32":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow32 = MW flow for given Interconnector for Scenario 32","examples":["0"],"is_float":true},"MWFLOW33":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow33 = MW flow for given Interconnector for Scenario 33","examples":["0"],"is_float":true},"MWFLOW34":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow34 = MW flow for given Interconnector for Scenario 34","examples":["0"],"is_float":true},"MWFLOW35":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow35 = MW flow for given Interconnector for Scenario 35","examples":["0"],"is_float":true},"MWFLOW36":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow36 = MW flow for given Interconnector for Scenario 36","examples":["0"],"is_float":true},"MWFLOW37":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow37 = MW flow for given Interconnector for Scenario 37","examples":["0"],"is_float":true},"MWFLOW38":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow38 = MW flow for given Interconnector for Scenario 38","examples":["0"],"is_float":true},"MWFLOW39":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow39 = MW flow for given Interconnector for Scenario 39","examples":["0"],"is_float":true},"MWFLOW40":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow40 = MW flow for given Interconnector for Scenario 40","examples":["0"],"is_float":true},"MWFLOW41":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow41 = MW flow for given Interconnector for Scenario 41","examples":["0"],"is_float":true},"MWFLOW42":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow42 = MW flow for given Interconnector for Scenario 42","examples":["0"],"is_float":true},"MWFLOW43":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW Flow value. Flow43 = MW flow for given Interconnector for Scenario 43","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_INTERSENSITIVITIES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17061733,"decompressed_size_all_time":4307420460},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_LOCAL_PRICE":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"LOCAL_PRICE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#58"],"comment":"Sets out local pricing offsets associated with each DUID connection point for each dispatch period","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"indexes":[["RUN_DATETIME","INTERVAL_DATETIME","DUID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["AGLSOM","ARWF1","BALB1","BALDHWF1","BANN1","BDL01","BDL02","BHB1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","CHYTWF1","COHUNSF1","COLEASF1","CROWLWF1","CRWARP1","CRWASF1","DARLSF1","DARTM1","DUNDWF1","DUNDWF2","DUNDWF3","EILDON1","EILDON2","ELAINWF1","FINLYSF1","GANNB1","GANNSF1","GIRGSF","GLENSF1","GLRWNSF1","GOESF1","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","HBESS1","HD1WF1","HILLSTN1","HUMEV","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","KARSF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","LANCSF1","LIMBESS1","LIMOSF11","LIMOSF21","LNGS1","LNGS2","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MCKAY1","MERCER01","MLB01","MOKOSF1","MOORAWF1","MORTLK11","MORTLK12","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MTGELWF1","MURRAY","MUWAWF1","MUWAWF2","NPS","NUMURSF1","OAKLAND1","PIBESS1","PLBESS1","RANGEB1","RYANCWF1","SALTCRK1","STOCKYD1","STWF1","SUNRSF1","TRGBESS1","VBB1","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","WEMENSF1","WINTSF1","WKIEWA1","WUNUSF1","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this unit: Sum(MarginalValue x Factor) for all relevant Constraints","examples":["-0.19","0.22","-2","48.5"],"is_float":true},"LOCALLY_CONSTRAINED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["1","2"],"is_integer":true,"num_int_bits":8}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_LOCAL_PRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":34921010,"decompressed_size_all_time":6332676220},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_PRICESENSITIVITIES":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"PRICESENSITIVITIES","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#66"],"comment":"Price Sensitivies for 5MinPD solution. New solution every 5 minutes. Current Scenarios defined in P5MIN_SCENARIODEMANDTRK/P5MIN_SCENARIODEMAND","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Definitive Run from which this solution derives","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Whether an Intervention constraint was defined in this run","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_PRICESENSITIVITIES."],"is_boolean":true},"INTERVENTION_ACTIVE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes","examples":["0"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp when this record was last modified","examples":["2026/09/01 00:01:29"],"parse_csv_as_string":true,"is_s_datetime":true},"RRP1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 1","examples":["-0.04343","0.00003","90","88.75296"],"is_float":true},"RRP2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 2","examples":["-0.04343","0.00003","43","67.49593"],"is_float":true},"RRP3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 3","examples":["-0.04343","0.00003","90","97.73002"],"is_float":true},"RRP4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 4","examples":["0.00003","83.99"],"is_float":true},"RRP5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 5","examples":["-0.04343","0.00003","0","79.05483"],"is_float":true},"RRP6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 6","examples":["0.00003","52","84.72588"],"is_float":true},"RRP7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 7","examples":["0.00003","83.99"],"is_float":true},"RRP8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 8","examples":["-0.04255","0.00003","-0.05261","79.05483"],"is_float":true},"RRP9":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 9","examples":["0.00003","83.99"],"is_float":true},"RRP10":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 10","examples":["-0.04343","0.00003","83.9901"],"is_float":true},"RRP11":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 11","examples":["-0.04343","0.00003","43","77.07695"],"is_float":true},"RRP12":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 12","examples":["-0.04343","0.00003","90","89.41077"],"is_float":true},"RRP13":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 13","examples":["0.00003","83.99"],"is_float":true},"RRP14":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 14","examples":["-0.04335","0.00003","-0.05278","83.99"],"is_float":true},"RRP15":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 15","examples":["0.00003","83.99"],"is_float":true},"RRP16":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 16","examples":["0"],"is_float":true},"RRP17":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 17","examples":["0"],"is_float":true},"RRP18":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 18","examples":["0"],"is_float":true},"RRP19":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 19","examples":["0"],"is_float":true},"RRP20":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 20","examples":["0"],"is_float":true},"RRP21":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 21","examples":["0"],"is_float":true},"RRP22":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 22","examples":["0"],"is_float":true},"RRP23":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 23","examples":["0"],"is_float":true},"RRP24":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 24","examples":["0"],"is_float":true},"RRP25":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 25","examples":["0"],"is_float":true},"RRP26":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 26","examples":["0"],"is_float":true},"RRP27":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 27","examples":["0"],"is_float":true},"RRP28":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 28","examples":["0"],"is_float":true},"RRP29":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 29","examples":["0"],"is_float":true},"RRP30":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 30","examples":["0"],"is_float":true},"RRP31":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 31","examples":["0"],"is_float":true},"RRP32":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 32","examples":["0"],"is_float":true},"RRP33":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 33","examples":["0"],"is_float":true},"RRP34":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 34","examples":["0"],"is_float":true},"RRP35":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 35","examples":["0"],"is_float":true},"RRP36":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 36","examples":["0"],"is_float":true},"RRP37":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 37","examples":["0"],"is_float":true},"RRP38":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 38","examples":["0"],"is_float":true},"RRP39":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 39","examples":["0"],"is_float":true},"RRP40":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 40","examples":["0"],"is_float":true},"RRP41":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 41","examples":["0"],"is_float":true},"RRP42":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 42","examples":["0"],"is_float":true},"RRP43":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference price for scenario 43","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_PRICESENSITIVITIES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":18282517,"decompressed_size_all_time":4700529040},"visibility":"Public","trigger":"Every 5 minutes"},"P5MIN_REGIONSOLUTION":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":10}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41.htm#72","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41_1.htm","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec41_2.htm"],"comment":"The five-minute predispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The 5-minute Predispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_REGIONSOLUTION shows the results of the regional capacity, maximum surplus reserve and maximum spare capacity evaluations for each period of the study.","description":"P5MIN_REGIONSOLUTION is public data, so is available to all\nparticipants.\n\nSource\n\nP5MIN_REGIONSOLUTION updates every 5 minutes.\n\nVolume\n\nRows per day: 1440","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AGGREGATEDISPATCHERROR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate dispatch error applied","examples":["-0.25149","0.48002","0","12.67854"],"is_float":true},"AVAILABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Available generation","examples":["1846.525","11483","11616.886"],"is_float":true},"AVAILABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Available Load","examples":["0","925","2440"],"is_float":true},"BDU_CLEAREDMW_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of export (Generation)","examples":["0","2","11"],"is_float":true},"BDU_CLEAREDMW_LOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of import (Load)","examples":["21.3101","0","1","348"],"is_float":true},"BDU_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated energy storage where the DUID type is BDU (MWh)","examples":["224.08156","1065.56368"],"is_float":true},"BDU_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy Storage for BDU at the start of the interval(MWh) - Region Aggregated","examples":["224.08156","1065.98763"],"is_float":true},"BDU_MAX_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available generation side BDU summated for region (MW)","examples":["337","1956"],"is_float":true},"BDU_MIN_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available load side BDU summated for region (MW)","examples":["925","2440"],"is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of cleared generation and import for region","examples":["931.24","1421","7964.78","7690"],"is_float":true},"DECGEN_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy storage for Daily Energy Constrained Scheduled Generating Units at the start of the interval(MWh) - Region Aggregated","is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["1014.69602","1421","8056.27129"],"is_float":true},"DEMANDFORECAST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Predicted change in regional demand for this interval","examples":["0","-1","1","5"],"is_float":true},"DISPATCHABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Generation Dispatched","examples":["490.24","1643","6916.95","6711"],"is_float":true},"DISPATCHABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Load Dispatched","examples":["21.31","0","1","348"],"is_float":true},"EXCESSGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Energy Imbalance (MW)","examples":["0"],"is_float":true},"INITIALSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of initial generation and import for region","examples":["931.24358","7964.78449"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_REGIONSOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:33"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Lower1Sec Dispatched in Region - RegionSolution element L1Dispatch attribute","examples":["0.25","0","2","62"],"is_float":true},"LOWER1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.01","0"],"is_float":true},"LOWER1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Lower 1Sec Price - RegionSolution element L1Price attribute","examples":["0.01","0"],"is_float":true},"LOWER5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min local dispatch","examples":["0.24","0","20","196"],"is_float":true},"LOWER5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Lower5Min)","examples":["0.01","0"],"is_float":true},"LOWER5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower5Min)","examples":["0.01","0"],"is_float":true},"LOWER6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec local dispatch","examples":["1.67","0","14","183"],"is_float":true},"LOWER6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Lower6Sec)","examples":["0.01","0","0.38"],"is_float":true},"LOWER6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower6Sec)","examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec local dispatch","examples":["1.67","0","14","213"],"is_float":true},"LOWER60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Lower60Sec)","examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower60Sec)","examples":["0.01","0","0.38"],"is_float":true},"LOWERREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation local dispatch","examples":["2.2","0","1","140"],"is_float":true},"LOWERREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (LowerReg)","examples":["0.01","0","1","2"],"is_float":true},"LOWERREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (LowerReg)","examples":["0.01","0","1","2"],"is_float":true},"NETINTERCHANGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector Flows","examples":["-14.21","7.11","0","1156"],"is_float":true},"RAISE1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Raise1Sec Dispatched in Region - RegionSolution element R1Dispatch attribute","examples":["71.41","0","16","218"],"is_float":true},"RAISE1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.02","0","0.03"],"is_float":true},"RAISE1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Raise 1Sec Price - R1Price attribute after capping/flooring","examples":["0.02","0","0.03"],"is_float":true},"RAISE5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min local dispatch","examples":["0.24","0","3","292"],"is_float":true},"RAISE5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Raise5Min)","examples":["0.01","0","0.38"],"is_float":true},"RAISE5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise5Min)","examples":["0.01","0","0.38"],"is_float":true},"RAISE6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec local dispatch","examples":["0.88","0","26","254"],"is_float":true},"RAISE6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Raise6Sec)","examples":["0.03","3","0.38"],"is_float":true},"RAISE6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise6Sec)","examples":["0.03","3","0.38"],"is_float":true},"RAISE60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 50 sec local dispatch","examples":["0.88","0","27","262"],"is_float":true},"RAISE60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (Raise60Sec)","examples":["0.01","3","1.3175"],"is_float":true},"RAISE60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise60Sec)","examples":["0.01","3","1.3175"],"is_float":true},"RAISEREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation local dispatch","examples":["8.23","0","1","179"],"is_float":true},"RAISEREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price (RaiseReg)","examples":["0.01","3","15.5","5"],"is_float":true},"RAISEREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (RaiseReg)","examples":["0.01","3","15.5","5"],"is_float":true},"ROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Override Price (Energy)","examples":["-0.04343","0.00003","83.99"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Energy)","examples":["-0.04343","0.00003","83.99"],"is_float":true},"SEMISCHEDULE_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW","examples":["101.525","2788.996"],"is_float":true},"SEMISCHEDULE_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced","examples":["10.628","0","60","231"],"is_float":true},"SS_SOLAR_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Solar units in that region","examples":["0"],"is_float":true},"SS_SOLAR_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is solar","examples":["0"],"is_float":true},"SS_SOLAR_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is solar","examples":["0"],"is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is solar","examples":["0"],"is_float":true},"SS_WIND_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Wind units in that region","examples":["101.525","1740","2855.742"],"is_float":true},"SS_WIND_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is wind","examples":["101.525","2788.996"],"is_float":true},"SS_WIND_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is wind","examples":["10.628","0","60","231"],"is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is wind","examples":["101.525","1740","2855.742"],"is_float":true},"TOTALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Demand - NB NOT net of Interconnector flows or Loads","examples":["931.24","5494","7842.27","5764"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["81.91603","0","284.99146"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["101.525","1740","2855.742"],"is_float":true},"WDR_AVAILABLE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated available MW for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"WDR_DISPATCHED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated dispatched MW for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"WDR_INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated MW value at start of interval for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"LOWER5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW dispatch","unused":true,"is_float":true},"LOWER5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW imported","unused":true,"is_float":true},"LOWER5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min total requirement","unused":true,"is_float":true},"LOWER5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min requirement","unused":true,"is_float":true},"LOWER6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW dispatch","unused":true,"is_float":true},"LOWER6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW imported","unused":true,"is_float":true},"LOWER6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec total requirement","unused":true,"is_float":true},"LOWER6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 seconds requirement","unused":true,"is_float":true},"LOWER60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW dispatch","unused":true,"is_float":true},"LOWER60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW imported","unused":true,"is_float":true},"LOWER60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec total requirement","unused":true,"is_float":true},"LOWER60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 seconds requirement","unused":true,"is_float":true},"LOWERREGDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Total Lower Regulation dispatch","examples":["0"],"unused":true,"is_float":true},"LOWERREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation MW imported","unused":true,"is_float":true},"LOWERREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation local requirement","unused":true,"is_float":true},"LOWERREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg local requirement","unused":true,"is_float":true},"LOWERREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation total requirement","unused":true,"is_float":true},"LOWERREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg requirement","unused":true,"is_float":true},"RAISE5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Total Raise 5 min MW dispatch","unused":true,"is_float":true},"RAISE5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW imported","unused":true,"is_float":true},"RAISE5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min total requirement","unused":true,"is_float":true},"RAISE5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min requirement","unused":true,"is_float":true},"RAISE6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW dispatch","unused":true,"is_float":true},"RAISE6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW imported","unused":true,"is_float":true},"RAISE6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec total requirement","unused":true,"is_float":true},"RAISE6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 seconds requirement","unused":true,"is_float":true},"RAISE60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW dispatch","unused":true,"is_float":true},"RAISE60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW imported","unused":true,"is_float":true},"RAISE60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec total requirement","unused":true,"is_float":true},"RAISE60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 seconds requirement","unused":true,"is_float":true},"RAISEREGDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Total Raise Regulation dispatch","examples":["0"],"unused":true,"is_float":true},"RAISEREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation MW imported","unused":true,"is_float":true},"RAISEREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation local requirement","unused":true,"is_float":true},"RAISEREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg local requirement","unused":true,"is_float":true},"RAISEREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation total requirement","unused":true,"is_float":true},"RAISEREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg requirement","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_REGIONSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":54165790,"decompressed_size_all_time":54784655720},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes","pagination":["Elec41_1.htm","Elec41_2.htm"]},"P5MIN_ROOFTOP_PV_FCST_TRK":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec42.htm#81"],"comment":"Uniquely tracks which Rooftop PV forecast run (from ROOFTOP_PV_FCST_P5_RUN) was used for the Area in which 5-Minute Pre-dispatch run.","primary_keys":["AREAID","RUN_DATETIME"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Area identifier aligning with the load forecasting areas, tracks to ROOFTOP_PV_FCST_P5_RUN.AREAID."},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) of the 5-Minute Pre-dispatch run.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Priority of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.FORECAST_PRIORITY.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime, unless a forecast run is missed, in this case the previous run is used. Tracks to ROOFTOP_PV_FCST_P5_RUN.FORECAST_RUN_DATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Submission datetime of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.OFFERDATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Provider identifier of the forecast run used for the DS run, tracks to ROOFTOP_PV_FCST_P5_RUN.PROVIDERID.","is_categorical":true}},"visibility":"Public","trigger":"Every 5 minutes when a new 5-Minute Pre-dispatch run is published"},"P5MIN_SCENARIODEMAND":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"SCENARIODEMAND","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec42.htm#87"],"comment":"The P5Min scenario MW offsets","primary_keys":["EFFECTIVEDATE","REGIONID","SCENARIO","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of this set of scenarios","examples":["2020/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region to which to apply the deltaMW for this SCENARIO","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCENARIO":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"The scenario identifier","examples":["1","15"],"is_integer":true,"num_int_bits":8},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The version of this set of scenarios","examples":["2020/06/03 16:15:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DELTAMW":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"The MW offset to apply to region total demand for this SCENARIO","examples":["-50","50","-200","350"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_SCENARIODEMAND%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":6},"last_month":{"year":2026,"month":9},"compressed_size_per_month":509,"decompressed_size_all_time":314980},"visibility":"Public","trigger":"On update of P5MIN scenarios"},"P5MIN_SCENARIODEMANDTRK":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"SCENARIODEMANDTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec42.htm#93"],"comment":"Tracks the 5Min scenario offset updates across time","primary_keys":["EFFECTIVEDATE","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of this set of scenarios","examples":["2020/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The version of this set of scenarios","examples":["2020/06/03 16:15:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the scenario update was authorised","examples":["2020/06/03 16:15:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2021/07/07 09:21:44"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23P5MIN_SCENARIODEMANDTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":6},"last_month":{"year":2026,"month":9},"compressed_size_per_month":441,"decompressed_size_all_time":271970},"visibility":"Public","trigger":"On update of P5MIN scenarios"},"P5MIN_UNITSOLUTION":{"package":"P5MIN","pdr_config":{"mappings":[{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"UNITSOLUTION","VERSION":6},{"REPORT_NAME":"P5MIN","REPORT_SUB_TYPE":"UNITSOLUTION","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec42.htm#99"],"comment":"The five-minute predispatch (P5Min) is a MMS system providing projected dispatch for 12 Dispatch cycles (one hour). The 5-minute Predispatch cycle runs every 5-minutes to produce a dispatch and pricing schedule to a 5-minute resolution covering the next hour, a total of twelve periods.\nP5MIN_UNITSOLUTION shows the Unit results from the capacity evaluations for each period of the study.","description":"P5MIN_UNITSOLUTION data is confidential, so shows own details for\nparticipant.\n\nSource\n\nP5MIN_UNITSOLUTION updates every 5 minutes for all units, even zero\ntargets.\n\nVolume\n\nRows per day: 57600\n\nBased on 200 units per Interval\n\nNote\n\nA bitwise flag exists for each ancillary service type such that a unit\ntrapped or stranded in one or more service type can be immediately\nidentified. The SPD Formulation document details the logic determining\nwhether a unit is \"trapped\" or \"stranded\". The flag is defined as\nfollows:\n\n| Flagged Condition   | Bit | Description                                                                                                                                                                                                     | Field value |\n|---------------------|-----|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|\n| FCAS profile active | 0   | The bid profile for this service has been activated such that the unit is available to be cleared to provide this ancillary service type.                                                                       | 1 or 3      |\n| Trapped             | 1   | The unit is enabled to provide this ancillary service type, however the profile for this service type is causing the unit to be trapped in the energy market.                                                   | 3           |\n| Stranded            | 2   | The unit is bid available to provide this ancillary service type, however, the unit is operating in the energy market outside of the profile for this service type and is stranded from providing this service. | 4           |","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["ADPBA1G","ADPBA1L","ADPPV1","AGLHAL","AGLSOM","ANGAST1","APD01","ARWF1","ASENGV01","ASENGY01","ASNAES1","ASNBRL1","ASNENC1","ASNSEL2","ASPAPM01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASSDE1","ASSEL1","ASSENC1","ASSERDV1","ASSSN1","ASTHYD1","ASVIEL2","AVLSF1","BALBG1","BALBL1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATRYL1","BBATTERY","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHBG1","BHBL1","BLOWERNG","BLUEGSF1","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1G","BOWWBA1L","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BROKENH1","BRYB1WF1","BRYB2WF2","BULBESG1","BULBESL1","BULGANA1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1G","CAPBES1L","CATHROCK","CBWWBA1G","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2024/07/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2024/07/01 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"AGCSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"AGC Status from EMS: 1 = on, 0 = off","examples":["0","1"],"is_integer":true,"num_int_bits":8},"AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Scheduled units, this is the MAXAVAIL bid availability For Semi-scheduled units, this is the lower of MAXAVAIL bid availability and UIGF","examples":["0.003","0","2","685"],"is_float":true},"CONFORMANCE_MODE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mode specific to units within an aggregate. 0 - no monitoring, 1 - aggregate monitoring, 2 - individual monitoring due to constraint","examples":["1"],"is_integer":true,"num_int_bits":32},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier for DUID","examples":["NASENG01","NASSAV01","NBA21B","NBAY1","NBAY2","NBAY3","NBAY4","NBB21B","NBES1B","NBK11B","NBKB1B","NBKB2B","NBLW8","NBOD1B","NCMA3B","NNRN1A","NQBC1C","NQBC2C","NRTAMAL1","NRTBORA1","NRTENOC1","NWGS1B","QASEEQ01","QBCB1B","QBCB2B","QBCG","QBGH1","QBGH2","QBRA1","QBRA2","QBRA3","QBRA5B","QBRA6B","QBRA7B","QCAB1","QCAB2","QCBS1B","QRTENOC1","SASDSC01","SASPAP01","SASSONN1","SASYES01","SASYES02","SASYES03","SBEL2P","SBEM1B","SBEM2B","SBPS1B","SCRK","SDRN1","SHPS1","SMVE4D","SMVE5D","SMVE6D","SMVE7C","SPGG1B","SPGW2B","SPGW3B","SPGW4B","SRTENOC1","SRTSAVP1","TBB11","TBB12","TBB13","TFA11","TRTHYDR1","VAPD1","VART1A","VASENG01","VASPWR01","VASSAV01","VASSER01","VBA21B","VBA22B","VBBT1B","VBBT2B","VBGT1B","VBGT2B","VBGT3B","VMWT2","VMWT3","VMWT9B","VTTS1","VWES1B"],"is_categorical":true},"DISPATCHMODETIME":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Minutes for which the unit has been in the current DISPATCHMODE. From NEMDE TRADERSOLUTION element FSTARGETMODETIME attribute.","examples":["0","10","65"],"is_integer":true,"num_int_bits":16},"ELEMENT_CAP":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Cap on the number of turbines or inverters at a DUID.","is_integer":true,"num_int_bits":32},"ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The projected energy storage based on cleared energy and regulation FCAS dispatch(MWh)","is_float":true},"ENERGY_STORAGE_MAX":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only - Maximum Energy Storage constraint limit (MWh)","is_float":true},"ENERGY_STORAGE_MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only - Minimum Energy Storage constraint limit (MWh)","is_float":true},"INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The energy storage at the start of this dispatch interval(MWh)","is_float":true},"INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial MW at start of period. For periods subsequent to the first period of a P5MIN run, this value represents the cleared target for the previous period of that P5MIN run. Negative values when Bi-directional Unit start from importing power, otherwise positive.","examples":["-0.1","0.001","0","575"],"warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run(INTERVENTION=1). In the event there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of P5MIN_UNITSOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2024/07/01 00:00:22"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Lower1Sec - TraderSolution element L1Target attribute","examples":["0","1","2"],"is_float":true},"LOWER1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element L1Flags attribute","examples":["0","1"],"is_boolean":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min reserve target","examples":["0","1","17"],"is_float":true},"LOWER5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 5min status flag","examples":["0","1"],"is_boolean":true},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec reserve target","examples":["17.54386","0","1","17"],"is_float":true},"LOWER6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 6sec status flag","examples":["0","1"],"is_boolean":true},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec reserve target","examples":["24.5614","0","1","17"],"is_float":true},"LOWER60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower 60sec status flag","examples":["0","1"],"is_boolean":true},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation reserve target","examples":["0"],"is_float":true},"LOWERREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lower Reg status flag","examples":["0","1"],"is_boolean":true},"MIN_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only. Load side availability (BidOfferPeriod.MAXAVAIL where DIRECTION = LOAD).","examples":["0"],"is_float":true},"RAISE1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Raise1Sec - TraderSolution element R1Target attribute","examples":["0","1","37"],"is_float":true},"RAISE1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element R1Flags attribute","examples":["0","1"],"is_boolean":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min reserve target","examples":["15.50991","0","1","114"],"is_float":true},"RAISE5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 5min status flag","examples":["0","1"],"is_boolean":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec reserve target","examples":["8.93161","0","1","21"],"is_float":true},"RAISE6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 6sec status flag","examples":["0","1"],"is_boolean":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec reserve target","examples":["0","1","100"],"is_float":true},"RAISE60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 60sec status flag","examples":["0","1"],"is_boolean":true},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation reserve target","examples":["0","1","10"],"is_float":true},"RAISEREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise Reg status flag","examples":["0","1"],"is_boolean":true},"RAMPDOWNRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp down rate (lessor of bid or telemetered rate).","examples":["28.8","0","60","6000"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp up rate (lessor of bid or telemetered rate).","examples":["28.8","0","60","6000"],"is_float":true},"SEMIDISPATCHCAP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Boolean representation flagging if the Target is Capped","examples":["0"],"is_boolean":true},"TOTALCLEARED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Target MW for end of period. Negative values when Bi-directional Unit is importing power, otherwise positive.","examples":["0.003","0","2","575"],"is_float":true},"TRADETYPE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Generator or Load","is_integer":true,"num_int_bits":8},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Unconstrained Intermittent Generation Forecast value provided to NEMDE","examples":["0.003","0","109.456"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_P5MIN_UNITSOLUTION_202407010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":7},"has_missing_months":true,"compressed_size_per_month":463964814,"decompressed_size_all_time":281571602100},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 5 minutes for all units, even zero targets"},"PARTICIPANT":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#115"],"comment":"PARTICIPANT sets out Participant ID, name and class for all participants.","description":"PARTICIPANT is public data, so is available to all participants.\n\nSource\n\nPARTICIPANT updates as new participants register or existing\nparticipants change details.","primary_keys":["PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","examples":["ACACIRET","ACACISGA","ACC","ACCELER","ACENERGY","ACLESGA","ACTEW","ACTEWAGL","ACTEWM","ACTEWMP","ACTEWNGY","ACTEWNWO","ACTEWP","ACTIONM","ACTIONMC","ACTIONMP","ACTIVENM","ACTIVMC","ACTIVMDP","ACTIVMP","ACUMEMDP","ACUMENMC","ACUMENMP","ADCHEM","ADVANCE","ADVANCEM","ADVANCEP","AEMC","AEMOLNGR","AEMOWEB1","AER","AES","AETVPOWR","AFP","AGGREKRT","AGILITYM","AGITNAMI","AGLAM","AGLE","AGLENRGY","AGLES","AGLESM","AGLESRT","AGLGASST","AGLGNNWO","AGLPARFQ","AGLPARFW","AGLQLD1","AGLQLD2","AGLSHYDR","AGLSQLD","AGLUPMOS","AGLUPSTR","AGLWG","AGLWGSA","AGORARET","AIRLENRG","ALCOA","ALCOAPA","ALCOAPRT","ALNTABUS","ALNTACEA","ALNTARES","ALNTBHWF","ALSAWCAI","ALSAWSME","AMALMASP","AMAYSIM","AMBER","AMBERELC","AMPOLCNI","AMPOLWST","ANZ","APAFACIL","APLNG","APSUSGA","APTALLG","APTAMHLD","APTPETRO","APTPIPE","ARARATWF","ARCADIA","ARCUMENM","ARMOURE","ARROW","ARROWSG","ARRWCSG","ARRWDANE","ARRWENRG","ARRWTPT2","ARRWTPTN","ARWBRAE2","ASTEELRT","ASX","ATTUNGA2","ATTUNGAC","ATTUNGAN","AUPACLNG","AUROLR","AURORA","AURORAD","AURORAMP","AURORAP","AUROTAS","AUSGASTR","AUSPG","AUSPGCI","AUSPGNSW","AUSPIPE","AUSTINDE","AUSTINL","AUSTINLP","AUSTRACL","B2PS","BALANCE","BALBESS","BANGOWF2","BARCAPAU","BASSLINK","BBPEM","BBPOWER","BBTHREE","BEACHE","BEAGAS","BERBANK","BERBANKW","BERYBKWF","BGCPART","BHPBPVIC","BHPPETRL","BLOOM","BLUENGY","BLUENRG","BLUEPCFI","BLUESCOP","BLUESCRT","BOCLTD","BOCLTDRT","BOCOROCK","BODWF1","BOMENSF","BORAL","BORALCMT","BORALRT","BOULBESS","BOWCSGPT","BOYNERT","BPAUS","BPENGAUS","BPSING","BRCSF","BRICKWRK","BRIGHTEN","BRIGHTON","BRIGHTSP","BROOKFDE","BULGANA","BUNGALA1","BUNGALA2","BWFTRUST","CADIART","CALTEX","CAPBESS","CAPEBYRN","CAPELEC","CAPELECP","CAPNSP","CAPRISF","CAPTPL","CARGILL","CATACT","CATHROCK","CAYMAN","CBA","CBWF","CER","CHALLHWF","CHERRYWF","CHFOURPT","CHOICENM","CITIP","CITIPP","CITIPWMP","CITYFIN","CLARESF1","CLEAN","CLEANCO","CLEANCOG","CLEANCOR","CLEANSGA","CLEMGPWF","CLERMSF","CLICK","CMC","CNOOCQGC","CNRGY","CNRGYMDP","CNRGYMPB","CNRGYP","CNTRLPET","CNTURION","CNUNDAWF","COALCO","COLEAMSF","COLLECWF","COLTSGA","COMET","COMO","COMSTEEL","CONCOCOP","CONTACTA","COOGEE","COOPER","COOPERS","COROWASF","COVAU","COZERO","COZEROER","CPEMRET","CPEMSGA","CPNETMDP","CQPCAP","CREATIVE","CREENSOL","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CSR","CSRBUILD","CSRETAIL","CSVCDROM","CULLRGWF","CUMMINS","DALRYMPN","DANSKECA","DARLPSF","DARLSF","DAYDSF","DDSF","DEATM","DEIBDL","DELTA","DELTAWST","DENISON","DEPTINDY","DEUREKA","DEUTSCHE","DIAMDGEN","DIAMDSGA","DIAMNDRT","DIAMOND","DIAPURWF","DIRLINKP","DISCOVER","DISCSGA","DMSMP","DODO","DOWJONES","DPESS","DPNTBESS","DUBBONA","DUBBOSK","DUNDWF","EAECOGEN","EAGENID","EARETALT","EARETID","EARETNXT","EASTENGY","EASTENM","EASTENMC","EASTENMP","EASTERN","EASTHALL","EASTSGA","EATALLA","EATRADE","EAXENM","ECOGEN","EDENVALE","EDGECAPT","EDISON","EDLCSM","EDLCSMQ","EDLGPSGA","EDLGRPOP","EDLLFGN","EDLLFGQ","EDLLFGS","EDLLFGV","EDLNGD","EDLOCI","EDLTT","EEQ","EEQGEN","EEQLILY","EEQMEWF","EEUS","EGXLTDMP","EINABOX","EIOSA","ELASSETS","ELECTDSM","ELECTRAG","ELETRADE","ELEXSGA","ELIXIR","ELLISAIR","EMPRENGY","ENCAP","ENDEAVRT","ENELAUS","ENELRET","ENERBRIX","ENERGEX","ENERGEXM","ENERGEXP","ENERGNSP","ENERGXMP","ENERGY21","ENERGYAT","ENERGYXM","ENERVEMP","ENERVENM","ENFOCENM","ENGAUSRT","ENGYAUST","ENGYAVIC","ENGYLOC","ENGYLOC2","ENGYLOC3","ENGYTALL","ENIAUSBV","ENLOCSGA","ENMENM","ENMSOENM","ENOCMASP","ENOCRT","ENOCSGA","ENOVAENG","ENRGYLIM","ENRGYONE","ENRON","ENRONAFT","ENSERVMG","ENVESTRA","ENVIROGN","ENVOAKY","EONENM","EOQLD","EPCSGA","EPCTECH","EPHOSGA","EPIC","EPMENM","EPOCHCAP","EPOCHNGY","EPVIC1","ERCENM","ERGON","ERGONETP","ERGONMP","ERMGEN","ERMPOWER","ERMPOWRT","ESC","ESIPCSAP","ESNRGY","ESSENTRT","ESSESAPS","ESSOAURT","ESSOAUS","ESTRNSUP","ETEX","ETSACOR","ETSAMDP","ETSAP","ETSAPMP","ETSAPP","ETSAPR","ETSAPVIC","ETSAPWR","ETSATM","ETSATP","ETSAUTIL","EVERENM","EVERGEN","EVERGETP","EWONSW","EWOVIC","FALCONAU","FERGUSWF","FERRIER","FEX","FINLEYSF","FIRMINFR","FIRMMASP","FIRMUSGD","FIRSTNRG","FLOENRGY","FNQEB","FNQEBP","FPC30","FRVROYAL","FSNSW","FUTUREX","GALILEE","GANNBESS","GANNDNSP","GANNSF","GBENERGY","GLENROSF","GLENSF","GLNGOPL","GLOBALM","GLOBIRD","GOENGSGA","GOON","GPENERGY","GPUPNMP","GPUPP","GR","GRANHAWF","GRDSHRE","GREENMC","GREENSP","GRIDBYND","GRIFFITH","GROUPNRG","GRSTHNGY","GSFM","GSOUTHM","GSOUTHP","GSPOWER","GSWF1A","GSWF1B","GULLENWF","GUNNEDAH","GUNNING","HAAST","HALLETT","HAMISF","HANWHA","HARTREE","HAUGHTSF","HAYMSF","HAZELPWR","HBESS","HELPDESK","HEPBURN","HESI","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HTWIND","HUGSF","HUMENM","HWF3","HYDROPWR","HYDROSA","HYDROTAS","ICAPAUST","ICAPBROK","ICRC","IEQLD","IERS","IES","IFORGERT","IFTCORP","IGUANA","IHUBENM","IHUBMC","IHUBMDP","IHUBMPB","IMCPAC","INCITECP","INFIGENH","INFISAGT","INFRATIL","INNOGYEN","INTEGM","INTEGMP","INTEGP","INTELENM","INTLENCU","INTLENGY","INTLIGENT","IOENERGY","IONAOPS","IPART","IPENERGY","IPRETAIL","ITPDSGA","JAKGREEN","JARDENSL","JEMASF","JENMDP","JMNACLNG","JMNADD3","JMNAEGP1","JMNAMLBP","JMNANGP","JMNAQLD1","JMNARNP","JMNAVICH","JPAENRGY","KABANWF","KARIT","KARSF","KENNEDYE","KIATAPRJ","KIATAWF","KIDSTON","KINETIK","KOGAGLNG","KSFPROJT","LAKEBLUE","LALLALWF","LANDFILL","LATTICEN","LBWPLB2","LDHENRGY","LIBERTY","LIFETRAD","LIGHTSRC","LIMONSF","LINGAPWF","LIQUIDET","LKBWFBES","LKBWIND","LMSENE","LMSGEN","LMSSGA","LOCALENM","LOCALITY","LOCALVOL","LOCHENG","LONGSGA","LONSDALE","LOYBPSOM","LOYYANGA","LPENERGY","LYGS","M2CENM","M2ENERGY","MACARTHR","MACBANK","MACKAY","MACKAYS","MACQGEN","MANILDRA","MANNUMS2","MAXENRGY","MBAHNTH","MBUTCHER","MCENERGY","MDYENM","MDYMC","MDYMDP","MDYMP","MEBP","MELBWATR","MEPAUPTY","MERCOMAS","MERIDIAN","MERIDSGA","METPL","METROENM","METROMC","METROMP","METZSF","MFTENRGY","MGPENM","MICHELLW","MICROGRD","MITSUIEP","MKTSORCE","MLCE","MNCNSP","MOBILOIL","MOLONGOP","MOLYCOP","MOMENM","MOMENTUM","MONDO","MONEYTEL","MOORAWF","MOREESF","MORGANCG","MORGANST","MORTLSWF","MORTONSL","MOUSF","MRYLINK1","MSATS","MTAENRGY","MTGELLWF","MTMERCER","MTMILLAR","MUGGALSP","MULTINET","MUWARRA2","MWARRA","MYENM","MYMC","NARRABRI","NECA","NECTR","NEMALERT","NEMITWEB","NEMITWEB1","NEMITWEB2","NEMMCO","NEMPMONNI","NEMRESTR","NEWENGSF","NEWGEN","NEWGRWF","NEXTBE","NEXTSGA","NORPOWER","NORQEB","NORQEBP","NORSKOA","NORSKOG","NORSPMRT","NORTHPM","NORTHPP","NOVAPWR","NOWDRU","NPMONN","NPMONQ","NPSAIL","NRSO","NSWEPL","NSWLUMO","NSWTREAS","NUMURKSF","NXTGDSGA","NYRSTAR","OCEANIA","OCNSP","OERARING","OES","OESR","OMFINANC","ONENERGY","ONESTCC","ONESTLRT","ONESTM","ONESTNRT","ONESTNSW","ONESTTRD","ONLINEPG","OPALPAPR","OPALRT","OPTIMA","OPTIMAR","OPTIVER","ORER","ORICA","ORICAINT","ORIGINER","ORIGINFE","ORIGINLP","ORIGINMC","ORIGINRT","ORIGINUS","ORIGINV","ORIGINX","ORIGNENM","ORORA","OVOENGY","OVOKALU","OZGRPL","PACBLUE","PACHYDIN","PACHYDRO","PACPOWER","PACTRAD","PAPERART","PAPERAUS","PAPLGLNG","PAPMICRO","PBLUESGA","PDVIEW","PEAKCO","PERPETEN","PETROCNI","PEVHSGA","PHOTNSGA","PHRETAIL","PINNOVRT","PIONEER","PIRIESGA","PLDENRGY","PLINKM","PLINKMP","PLINKP","POOLEDEN","POOLNSW","POOLQLD","POOLSA","POOLSNOW","POOLTAS","POOLVIC","PORTADL","PORTWF","POWCP","POWERCMP","POWERCOR","POWERL","POWERMDP","POWGEN","POWMEMDP","POWMETMC","POWMETMP","POWOW","POWRCLUB","POWRSHOP","POWRSHRT","POWRSSGA","PRIZEPET","PROGREEN","PROGRNRT","PROGRSGA","PRTDBORA","PRTDBSQL","PRTDBSYB","PSF","PULSE","PWRWATER","PYRENEES","PZESURAT","QALUMINA","QCA","QCLNGOPC","QENOS","QEPL","QERU","QGCLMTD","QGCLTDRT","QGCSALE1","QGCTOLL","QGCTOLL2","QGCTRAIN","QIPPTSRT","QLDLUMO","QLDRSO","QPMENGY","QPMMGP","QTPTC","QTSC","RADIAN","RADIANHO","RATCHAC","REAMPED","REAMPED2","REDBANK","REDDOLPH","REDDOLTP","REDSKYNT","RENEWSGA","REPOSTRT","RESPONSE","RIOTALBB","RIVEBESS","RMBAUST","RMSENM","ROAM","ROCKYPT","ROSSRVER","RWESUPPL","RYEPARK","SADEM","SADTEI","SAEPL","SALTCRK","SALUMO","SANTGLNG","SANTOCSG","SANTOQNT","SANTOS","SANTOSD","SANTOSTO","SAPHWF1","SAPNRT","SAS17ENM","SAVPP1","SAVVYPE","SAWATER","SAWC","SAWCML","SAWCRT","SAWCSGA","SBESSGA","SEAUGAS","SEBSF","SECURENG","SECURMDP","SECV","SENEXAST","SEPN1ENM","SERDR","SERSGA","SGAUSLT","SGAUST","SGHENRGY","SGMTRADE","SHELLEA","SHELLNEW","SHOAL","SIMPSME","SITHE","SKILTHMP","SLEIMAN","SMARTEGY","SMCTSV","SMORGON","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWTRAD","SNOWY","SNOWYNRG","SNOWYP","SNOWYSC1","SNOWYSC2","SNOWYSC3","SNOWYSC4","SOCIALEA","SOLARIS","SOLARISP","SOLARMP","SONNEN","SONNMASP","SORTED","SOUTHHYD","SOUTHNGD","SOUTHWP","SOUTHYD2","SPANMDP","SPARQ","SPAUSNET","SPTLSSMC","SPTLSSMP","SQWTRSGA","SSENM","STANCEA","STANRET","STANSGA","STANWELL","STARFISH","STHSTSGA","STHWESTP","STHYDSGA","STOCKYRD","SUCROGEN","SUMOPOWR","SUNRSF","SUNTOP","SUNTSV","SYTHE","TAILEM","TALL","TAMBORAN","TANGO","TARACTEC","TARALGA","TARONG","TASGAS","TASIRRIG","TASPIPE","TBLANDGP","TBSOL","TCAMP","TCAUSTM","TELSTRA","TELSTRAE","TELSTRAR","TELSTSGA","TESLAMRT","TFSAUS","TGSERVP","TIBELE01","TILTSGA","TIPSCO","TOA","TOA2","TOKYOQGC","TOMAGOAC","TOORAWF","TOTAGLNG","TOTALGP","TOTLGPAP","TRANSEND","TRANSGBH","TRANSGM","TRANSGMP","TRANSGP","TRISTAR","TRUDW","TTEGEENM","TYCOWATR","UEDMDP","UMPLP","UNIOFQLD","UNIQLDSF","UNITED","UNITEDDP","UNITEDEN","UNITEDMP","UNITEDRT","UNNGYMKT","URTH","VECTOMDP","VECTORMC","VECTORMP","VELOCSGA","VEPL","VESTTGEN","VICGASDB","VICLUMO","VICPNRT","VICPOL","VINTAGE","VIOTAS","VIOTASRT","VISYPAPR","VISYRT","VIVAENG","VIVAENRT","VIVCOUR2","VIVCOURT","VOLTENM","VPX","VPXP","VRTSYSMC","VRTTEKMC","VWATT","WAGGAOPS","WALGBESS","WALLOONS","WATERLWF","WATTSENM","WBAYM","WBBEBP","WDOWNS","WELLNTH","WEMENSF","WEPROG","WERADUNI","WERCSIRO","WESTON","WESTONAL","WESTPAC","WESTSDEA","WESTSDED","WGWF","WHECKSON","WHILL1","WHYDNSP","WIDEBAYB","WILDCATL","WINENM","WINRET","WINRETCC","WINRETWF","WINTONSF","WONTHGWF","WOODLAWN","WOOLOOGA","WPWF","WROCKWF","WSTRACRT","WSTSDECO","WSUNDAY","WYALONG","WYASF","XELIO","YALLNR","YALLOURN","YALSTHWF","YAMASA","YARRANSF","YARWUN","YARWUNRT","YATESSGA","YATSF","YDMKSGA","YDPSGA","YESSA","YESSASGA","YURIKART","ZENENRGY","ZINIFEX"],"is_categorical":true},"ACN":{"sql_type":"VARCHAR2(9)","pl_type":"str","mandatory":false,"comment":"Australian Company Number; Nine Numbers XXX-XXX-XXX"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:01:22"],"parse_csv_as_string":true,"is_s_datetime":true},"NAME":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Full name of participant","examples":["1st Energy Pty Ltd","ACLE Services Pty Ltd","ACT Civil & Administrative Tribunal","ADZ Energy (Queensland) P/L(Administrators Appt)(Receivers & Managers Appt)","AEMO (NDSC-North)","AEMO (NDSC-South)","AEMO Help Desk","AEMO IT Web Interface","AEMO Internal Account NECA Information Protocol","AEMO Internal DI Participant Account 1","AEMO Internal DI Participant Account 2","AEMO Internal DI Participant Account 3","AEMO Internal Monitoring And Alerting Account","AEMO Internal Reporting CSV DVD","AEMO LNG Reserve","AEMO NSW Monitor","AEMO QLD Monitor","AEMO Reserve Trader","AETV Pty Ltd","AGI Tanami Pty Limited","AGL Australia Markets Pty Limited","AGL Dalrymple Pty Limited","AGL Energy Limited","AGL Energy Sales & Marketing Pty Ltd","AGL Energy Services (Queensland) Pty Limited","AGL Energy Services Pty Limited","AGL Gas Storage Pty Ltd","AGL Hydro Partnership","AGL Loy Yang Marketing Pty Ltd","AGL Macquarie Pty Limited","AGL PARF NSW Pty Ltd","AGL PARF QLD Pty Limited","AGL SA Generation Pty Limited","AGL Sales (Queensland Electricity) Pty Limited","AGL Sales (Queensland) Pty Ltd","AGL Sales Pty Limited","AGL South Australia Pty Ltd","AGL Southern Hydro (NSW) Pty Limited","AGL Upstream Gas (MOS) N.L","AGL Upstream Investments Pty Limited","AGL Wholesale Gas (SA) Pty Ltd","AGL Wholesale Gas Limited","APA Facilities Management Pty Ltd","APA Group Limited ATF APA Infrastructure Trust","APA Infrastructure Limited","APT AM Holdings Pty Ltd","APT Petroleum Pipelines Pty Limited","ASX Operations Pty Limited","Acacia Energy Pty Ltd","Actew Distribution Ltd","Actew Energy Limited","Active Stream Pty Ltd","Acumen Metering Pty Ltd","Adchem (Australia) Pty Ltd","Adelaide Brighton Cement Ltd","Aggreko Generator Rentals Pty Ltd","Agora Retail Pty Ltd","Airlie Energy Pty Ltd","Alcoa Of Australia Limited","Alcoa Portland Aluminium Pty Ltd","Alinta EATM Pty Ltd","Alinta Energy Cea Trading Pty Ltd","Alinta Energy Retail Sales Pty Ltd","Alinta Sales Pty Ltd","Allgas Energy Pty Limited","Amalgamated Energy Services Pty Ltd","Amber Electric Pty Ltd","Ampol Energy (Retail) Pty Ltd","Ampol Energy (Wholesale Trading) Pty Ltd","Ampol Refineries (QLD) Pty Ltd","Anglo Coal (CapCoal Management) Pty Limited","Anglo Coal (Moranbah North Management) Pty Ltd","Apsu Power Pty Ltd","Ararat Wind Farm Pty Ltd","Arc Utilities Management Pty Ltd","Arcadia Energy Trading Pty Ltd","Arrow (Daandine) Pty Ltd","Arrow (Southern Generation) Pty Ltd","Arrow (Tipton Two) Pty Ltd","Arrow (Tipton) Pty Ltd","Arrow Braemar 2 Pty Ltd","Arrow CSG (Australia) Pty Ltd","Arrow Energy Pty Ltd","Arrow Energy Trading Pty Ltd","Arrow Southern Generation Pty Ltd And Arrow Braemar 2 Pty Ltd","Attunga Capital Pty Ltd","Aurora Energy Pty Ltd","Aus Gas Trading Pty Ltd","AusNet Electricity Services Pty Ltd","AusNet Gas Services Pty Ltd","AusNet Transmission Group Pty Ltd","Austraclear Ltd","Australia And New Zealand Banking Group Limited","Australia Pacific LNG Marketing Pty Limited","Australia Pacific LNG Pty Limited","Australian Competition & Consumer Commission","Australian Continental Energy Pty Ltd","Australian Crime Commission","Australian Energy Market Commission","Australian Energy Market Operator Limited","Australian Energy Market Operator Limited.","Australian Federal Police","Australian Gas Networks (Vic) Pty Ltd","Australian Gas Networks Limited","Australian Industrial Energy Pty Ltd","B P Australia Pty Ltd","BEA Gas Pty Ltd","BESS Longwarry Pty Ltd","BGC Partners (Australia) Pty Limited","BHP Billiton Petroleum (Victoria) Pty Ltd","BOC Limited","BOYNE SMELTERS LIMITED","BP Energy Asia Pte Limited","BP Energy Australia Pty Ltd","BWF Nominees Pty Ltd As The Trustee For BWF Trust","Balance Commodities And Energy Pty Ltd","Barcaldine Remote Community Solar Farm Pty Ltd","Barclays Bank PLC","Basslink Pty Ltd","Beach Energy (Operations) Limited","Beach Energy Limited","Beetaloo Energy Australia Limited","Bell Bay Power Pty Ltd","Berrybank 2 Asset Pty Ltd As The Trustee For Berrybank 2 Asset Trust","Berrybank Development Pty Ltd","Birdwood Trading Pty Ltd","Bloomberg - Non Code Participant","Blue Energy Limited","Blue NRG Pty Ltd","Blue Pacific Energy Pty Ltd","BlueScope Steel Limited","Bluecurrent (Australia) Pty Limited","Bluescope Steel Limited","Boco Rock Wind Farm Pty Ltd","Bodangora Wind Farm Pty Limited","Bomen Solar Farm Pty Ltd As Trustee For Bomen SF Trust","Boortmalt Asia Pacific Pty Ltd","Boral Cement Limited","Bouldercombe Battery Project Co Pty Ltd ATF Bouldercombe Battery Project","Bow CSG Pty Ltd","Braemar Power Project Pty Ltd","Brickworks Building Products Pty Ltd","Bright Spark Power Pty Limited","Brighte Energy Pty Ltd","Bulgana Wind Farm Pty Ltd","Bungala One Operations Pty Ltd As Trustee For The Bungala One Operations Trust","Bungala Two Operations Pty Ltd As Trustee For The Bungala Two Operations Trust","CH4 PTY LTD","CNOOC QCLNG Tolling Pty Ltd","COzero Energy Retail Pty Ltd","CPE Mascot Pty Ltd","CQP Capital Pty Ltd","CRWF Nominees Pty Ltd As Trustee For The CRWF Trust","CS Energy Limited","CSIRO - Commonweatlth Scientific & Industrial Research Organisation","CSR Building Products Limited","CSR Limited","Cadia Holdings Pty Ltd","Callide Power Trading Pty Limited","Canunda Power Pty Ltd","Cape Byron Management Pty Ltd","Capital Battery Pty Ltd As Trustee For Capital Battery Trust","Capricorn SF No1 Pty Ltd","Capricornia Electricity Corporation Ltd","Capricornia Electricity Corporation Ltd (Capelec) (DNSP)","Castleton Commodities Merchant Asia Co Pte Ltd","Cathedral Rocks Wind Farm Pty Ltd","Cayman Emerging Manager Platform SPC Bold Capital Master Fund 2 SP","Central Petroleum Limited","Cherry Tree Wind Farm Pty Ltd As Trustee For The Cherry Tree Project Trust","Childers Solar Pty Ltd ATF The Childers Solar Trust","Choice Metering Pty Ltd","CitiPower Pty","City Financials Investment Company (New Zealand)","Clare Solar Farm Pty Ltd","Clean Energy Regulator","Clean Energy Transfer Fund Investments Pty Ltd ATFT Clean Energy Transfer Fund","CleanCo Queensland Limited","Clermont Asset Co Pty Ltd ATF Clermont Solar Unit Trust","Click Energy Pty Ltd","Coleambally Solar Pty Ltd","Collector Wind Farm Pty Ltd","Colt Energy Pty Ltd","Comet Ridge Ltd","Commonwealth Bank Of Australia","Commonwealth Steel Company Pty Limited","Como Glasshouse No2 Pty Ltd","ConocoPhillips Australia Operations Pty Ltd","Coogee Energy Pty Ltd","Coonooer Bridge Wind Farm Pty Ltd","Cooper Energy (Marketing) Pty Ltd","Coopers Brewery Limited","Corowa Operationsco Pty Ltd As The Trustee For Corowa Operations Trust","Country Energy","Country Energy (DNSP)","Country Energy (MDA)","Covau Pty Limited","Creative Analytics Pty Ltd","Creative Energy Solutions Pty Ltd","Crime And Misconduct Commission","Crookwell 3 Development Pty Ltd","Crookwell Development Pty Ltd","Cullerin Range Wind Farm Pty Ltd","Cummins South Pacific Pty Ltd","DIRECTLINK JOINT VENTURE","DPESS Pty Ltd ATF The DPESS Trust","Danske Commodities Australia Pty Limited","Darling Downs Solar Farm Pty Ltd","Darlington Point Solar Farm Pty Ltd","Daydream Solar Farm Pty Ltd As The Trustee For The Daydream Solar Farm Trust","Delta Power & Energy (Vales Point) Pty Ltd","Denison Gas Ltd","Department Of Industry","Department Of The Premier And Cabinet","Deutsche Bank AG","Diamond Energy Pty Ltd","Diapur Wind Farm Pty Ltd","Discover Energy Pty Ltd","Dow Jones - Non Code Participant","Dubbo Solar Hub Pty Ltd","Dundonnell Wind Farm Pty Ltd","Dyno Nobel Limited","EDL (OCI) Pty Limited","EDL (TT) Pty Limited","EDL CSM (NSW) Pty Ltd","EDL CSM (QLD) Pty Ltd","EDL Group Operations Pty Ltd","EDL LFG (NSW) Pty Ltd","EDL LFG (Qld) Pty Ltd","EDL LFG (SA) Pty Ltd","EDL LFG (Vic) Pty Ltd","EDL NGD (NT) Pty Ltd","EDL Projects (Australia) Pty Ltd","EDPR AUSTRALIA PTY LTD","EL Retail Energy Pty Ltd","ENGIE","ENM Solutions Pty Ltd","ETEX Australia Pty Ltd","ETSA Corporation","ETSA Power Corporation","ETSA Power Corporation Victoria Pty Ltd","ETSA Transmission Metering","ETSA Utilities Pty Ltd","Eastern Energy Supply Pty Ltd","Edenvale Solar Park Pty Ltd","EdgeCap Pty Ltd","ElectraNet Pty Limited","Electrade II Pty Ltd","Electrag Pty Ltd","Elexsys Energy Trading Pty Ltd","Elixir Energy Limited","Ellis Air Connect Pty Ltd","Encap Funds Management Pty Limited","Endeavour Energy Network Operator Partnership","Enel X Australia Pty Ltd","Energex (NSP)","Energex Limited","Energy Action (Australia) Pty Ltd","Energy And Plant Management Pty Ltd","Energy And Water Ombudsman Of New South Wales","Energy And Water Ombudsman Of Victoria","Energy Brix Australia Corporation Pty Ltd","Energy Industry Ombudsman (SA) Limited","Energy Intelligence Pty Ltd","Energy Ombudsman Queensland","Energy On Pty Ltd","Energy One Limited","Energy One Pty Ltd","Energy Pacific (Vic) Pty Ltd","Energy Resources Corporation Pty Ltd","Energy Services Management Pty Ltd","EnergyAustralia","EnergyAustralia Ecogen Pty Ltd","EnergyAustralia Hallett Pty Ltd","EnergyAustralia Pty Ltd","EnergyAustralia Tallawarra Pipelines Pty Ltd","EnergyAustralia Tallawarra Pty Ltd","EnergyAustralia Yallourn Pty Ltd","EnergyX Markets Pty Ltd","Energyfocus SEM Pty Ltd","Enerven Energy Infrastructure Pty Ltd","Eni Australia B.V.","Enova Energy Pty Ltd (Administrators Appointed)","Enron Australia Energy Pty Ltd","Enron Australia Finance Pty Ltd","Envirogen Pty Limited","Epho Asset Management Pty Ltd","Epic Energy South Australia Pty Limited","Epoch Capital Pty Ltd","Epoch Energy Solutions Pty Ltd","Ergon Energy Corporation Limited","Ergon Energy Queensland Pty Ltd","Essential Energy","Essential Services Commission","Esso Australia Resources Pty Ltd","Evergen Pty Limited","Evergy Pty Ltd","FAR North Queensland Electricity Corporation Ltd","FS NSW Project No 1 At Pty Ltd ATF The FS NSW Project No 1 Asset Trust","Falcon Oil & Gas Australia Limited","Far North Queensland Electricity Corporation Ltd (FNQEB DNSP)","Ferguson Wind Farm Pty Ltd","Financial & Energy Exchange Limited","Firmus Grid Pty Ltd","Firmus Infrastructure Pty Ltd","Flinders Operating Services Pty Ltd","Flinders Power Pty Ltd","Flo Energy Australia Pty Ltd","GB Energy (VIC) Pty Limited","GLNG Operations Pty Ltd","GSP Energy Pty Ltd","Galilee Energy Limited","Gannawarra Solar Farm Pty Ltd","Genex (Solar) Pty Ltd","Genuity Retail Pty Ltd","Glenrowan Solar Farm Pty Ltd As Trustee For Glenrowan Solar Farm Trust","GloBird Energy Pty Ltd","Global-Roam Pty Ltd","GoEnergy Pty Ltd","Goldman Sachs Financial Markets Pty Ltd","Goonumbla Asset Co Pty Ltd As The Trustee For Goonumbla Asset Trust","Goyder Wind Farm 1 Pty Ltd ATF Goyder Wind Farm 1 Trust","Goyder Wind Farm 1B Pty Ltd ATF Goyder Wind Farm 1B Trust","Green Metering Pty Ltd","Green Pacific Energy Stapylton No 1 Pty Ltd ","Grid Share Pty Ltd","GridBeyond Pty Ltd","Griffith Solar Farm Pty Ltd","Group Energy Pty Ltd","Gullen Range Wind Farm Pty Ltd","Gunnedah SF Pty Ltd As Trustee For Gunnedah Asset Trust","Gunning Wind Energy Developments Pty Ltd","HWF 2 Pty Ltd","HWF1 Pty Ltd","HWF3 Pty Ltd","Haast Energy Trading Limited","Hamilton Solar Farm Pty Ltd","Hanwha Energy Retail Australia Pty Ltd","Hartree Partners, LP","Hayman Solar Farm Pty Ltd As The Trustee For The Hayman Solar Farm Trust","Hazelwood BESS Project Co Pty Ltd ATF The HBESS Asset Trust","Hazelwood Power","Henwood Energy Services (Non Code Participant)","Hillston Sun Farm Operations Pty Ltd ATF Hillston Sun Farm Operations Trust","Hornsdale Power Reserve Pty Ltd","Hughenden Solar Pty Limited As Trustee For Hughenden Solar Trust","Humenergy Group Pty Ltd","Hydro Power Pty Limited","Hydro-Electric Corporation","ICAP Australia Pty Limited","ICAP Brokers Pty Limited","IFT Corporation Pty Ltd","IMC Pacific Pty Ltd","Iberdrola Australia Energy Markets Pty Limited","Iberdrola Australia Holdings Pty Limited","Iberdrola Australia SAGT Pty Limited","Iberdrola Australia Wallgrove Pty Limited","Icon Distribution Investments Limited And Jemena Networks (ACT) Pty Ltd","Icon Retail Investments And AGL ACT Retail Investments Pty Ltd","Iguanadata Pty Ltd","Incite Energy Pty Ltd","Independent Competition And Regulatory Commission","Independent Electricity Retail Solutions Pty Ltd","Independent Pricing And Regulatory Tribunal Of NSW","Infrabuild NSW Pty Ltd","IntelliHUB Pty Ltd","Intelligent Energy Systems Pty Ltd","Intellihub Pty Ltd","Intercast & Forge Pty Limited","Interface to NEMMCO web site","Internal MSATS Participant","International Power (Energy) Pty Ltd","Iraak Sun Farm Pty Ltd","JPA Energy Pty Ltd","Jackgreen (International) Pty Ltd","Jarden Securities Limited","Jemalong PV Asset Pty Ltd As Trustee For The Jemalong PV Asset Trust","Jemena Colongra Pty Ltd","Jemena Darling Downs Pipeline (3) Pty Ltd","Jemena Eastern Gas Pipeline (1) Pty Ltd","Jemena Electricity Networks (VIC) Limited","Jemena Electricity Networks (VIC) Ltd","Jemena Electricity Networks (Vic) Ltd","Jemena Gas Networks (NSW) Ltd","Jemena Malabar Pipeline Pty Ltd","Jemena Northern Gas Pipeline Pty Ltd","Jemena Queensland Gas Pipeline (1) Pty Ltd","Jemena Roma North Pipeline Pty Ltd","Jemena VicHub Pipeline Pty Ltd","KGLNG Liquefaction Pty Ltd","KSF Project Nominees Pty Ltd As The Trustee For KSF Project Trust","Kaban Wind Farm Pty Ltd As Trustee For Kaban Wind Farm Trust","Karit (Australia) Pty Ltd","Kennedy Energy Park Pty Ltd","Kiata ProjectCo Pty Ltd Atf Kiata Project Trust","Kiata Wind Farm Pty Ltd","Kinetik Energy Pty Ltd","LMS Energy Pty Ltd","LYB Operations & Maintenance Pty Ltd","Lake Bonney Wind Power Pty Ltd","Lakes Blue Energy NL","Lal Lal Wind Farms Nom Co Pty Ltd","Landfill Operations Pty Ltd","Liberty Greenpower Pty Ltd","Life Trading Pty Ltd","Lightsource Australia SPV 4 Pty Ltd","Limondale Sun Farm Pty Ltd","Lincoln Gap Wind Farm (Operations) Pty Ltd","Locality Embedded Networks Pty Limited","Locality Planning Energy Pty Ltd","Localvolts Pty Ltd","Lochard Energy (Iona Operations Pty Ltd)","Lochard Energy (Iona Operations) Pty Ltd","Lumea Pty Ltd As Trustee For Lumea Trust","Lumo Energy (NSW) Pty Ltd","Lumo Energy (QLD) Pty Ltd","Lumo Energy (SA) Pty Ltd","Lumo Energy Australia Pty Ltd","Lumo Generation SA Pty Ltd","M2 Energy Pty Ltd (T/As Commander Power & Gas)","M2 Energy Pty Ltd (T/As Dodo Power & Gas)","MEPAU A Pty Ltd","MFT Energy Australia Pty Ltd","MOBIL OIL AUSTRALIA PTY LTD","MP Tableland Green Power Pty Ltd","MTA Energy Pty Limited","Macarthur Energy Retail Pty Ltd","Mackay Electricity Corporation Ltd","Mackay Electricity Corporation Ltd (DNSP)","Mackay Sugar Limited","Macquarie Bank Ltd","Mako Trading Australia Pty Ltd","Manildra Prop Pty Ltd As The Trustee For The Manildra Asset Trust","Mannum Stage 2 SubCo Pty Ltd As Trustee For The Mannum Stage 2 Unit Trust","Marden Energy Pty Ltd","MarketSource Financial Markets Pty Ltd","Master Butchers Co-Operative Ltd","Maximum Energy Retail Pty Ltd (In Liquidation)","Melbourne Water Corporation","Mercuria Commodity Markets (Asia) Pte. Ltd.","Merril Lynch Commodities (Europe) Limited","Meter 2 Cash Solutions Pty Ltd","Metering Dynamics Pty Ltd","Metropolis Metering Services Pty Ltd","Metz ProjectCo Pty Ltd As The Trustee For Metz ProjectCo Trust","Michell Wool Pty Limited","Microgrid Power Pty Ltd","MidOcean QCLNG Pty Ltd","Millmerran Energy Trader Pty Ltd","Mitsui E&P Australia Pty Ltd","Molong Operationsco Pty Ltd As The Trustee For Molong Operations Trust","Momentum Energy Pty Limited","Mondo Metering Pty Ltd","Moneyline Telerate International","Moorabool Wind Farm Interface Company Pty Ltd","Moree Solar Farm Pty Ltd","Morgan Stanley Australia Limited","Morgan Stanley Capital Group Inc","Mortlake South Wind Farm Pty Ltd","Mortons Lane Windfarm Pty Limited","Moura Solar Farm SPV Pty Ltd ATF Moura Solar Farm Unit Trust","Mt Mercer Windfarm Pty Ltd","Mt Millar Wind Farm Pty Ltd","Mt. Gellibrand Wind Farm Pty Ltd","Mugga Lane Solar Park Pty Ltd","Multinet Gas (DB No 1) Pty Ltd & Multinet Gas (DB No 2) Pty Ltd","Murra Warra II Project Co Pty Ltd ATF The Murra Warra II Project Trust","Murraylink Transmission Company Pty Ltd","NESF Pty Ltd As Trustee Of The New England Solar Project Trust","NSW Electricity Networks Ops P/L ATF NSW Electricity Networks Operations Trust","NSW Treasury","Neighbourhood Energy Pty Ltd","Nemmco Momitor - Non Code","New Gullen Range Wind Farm Pty Ltd","Next Business Energy Pty Ltd","NextGrid Energy Pty Ltd","No WDR Unit","Norske Skog Paper Mills (Albury) Pty. Limited","Norske Skog Paper Mills (Australia) Limited","Norske Skog Paper Mills (Australia) Ltd","North Queensland Electricity Corporation Ltd (NORQEB) (DNSP)","North queensland Electricity Corporation Ltd","Numurkah Solar Farm Pty Ltd","Nyrstar Port Pirie Pty Ltd","OM Financial Limited","OPTIMA Energy","OPTIMA Energy Retail","OVO Energy Pty Ltd","Oakey Power Holdings Pty Ltd","Oaky Creek Coal Pty Ltd","Oceania Glass Pty Ltd (Administrators Appointed)","Office Of The Renewable Energy Regulator","Office of Economic and Statistical Research (Non-Code Participant)","OneSteel Coil Coaters Pty Ltd","OneSteel Manufacturing P/L(Administrators Appointed)","OneSteel Manufacturing Pty Limited","OneSteel Manufacturing Pty Ltd ","OneSteel Trading Pty Limited","Online Power And Gas Pty Ltd","Onsite Energy Solutions Pty Ltd","Optiver Australia Pty Ltd","Orica Australia Pty Ltd","Orica International Pte Ltd","Origin Energy (VIC) Pty Ltd","Origin Energy Electricity Limited","Origin Energy Eraring Pty Ltd","Origin Energy LPG Limited","Origin Energy Metering Coordinator Pty Ltd","Origin Energy Retail Limited","Origin Energy Retail Ltd","Origin Energy Upstream Operator Pty Ltd","Orora Packaging Australia Pty Ltd","PA Power Microgrid 1 Pty Ltd","PACIFIC ENERGY TRADING PTY LTD","PAPL (Downstream) Pty Limited","PLUS ES","POWERLINK METERING","PZE (SURAT) Pty Ltd","Pacific Blue Retail Pty Ltd","Pacific Blue Smart Communities Pty Ltd","Pacific Energy (Hydro) Pty Ltd","Pacific Energy (Peaking Power) Pty Ltd","Pacific Hydro Challicum Hills Pty Ltd","Pacific Hydro Clements Gap Pty Ltd","Pacific Hydro Crowlands Pty Ltd","Pacific Hydro Haughton Solar Farm Pty Ltd","Pacific Hydro Investments Pty Ltd","Pacific Hydro Portland Wind Farm Pty Ltd","Pacific Hydro Yaloak South Pty Ltd","Paper Australia Pty Ltd","Parkes Solar Farm Pty Ltd","Pelican Point Power Limited","Pentair Water Solutions Limited","Perpetual Energy Pty Ltd","PetroChina International (Australia) Pty Ltd","Photon Energy SGA Pty Ltd","Pioneer Sugar Mills Pty Ltd","Pirie Solar Farm Pty Ltd","Planet Innovation Pty Ltd","Pooled Energy Pty Limited (In Liquidation) (Receivers And Managers Appointed)","Port Adelaide Energy Pty Ltd","Potentia Energy Retail Pty Ltd","Power And Water Corporation","Power Club Limited (in Liquidation)","Power Generation Corporation","PowerSync Pty Ltd","Powercor Australia Ltd","Powerdirect Pty Ltd","Powerlink Queensland","Powermetric Metering Pty Ltd","Powershop Australia Pty Limited","Powow Power Pty Ltd","Prize Petroleum International Pte. Ltd.","Progressive Green Pty Ltd","Progressive Green Pty Ltd (ta Flow Power)","Pyrenees Wind Energy Developments Pty Ltd","QCLNG Operating Company Pty Ltd","QGC Pty Limited","QGC Train 1 Tolling Pty Ltd","QGC Train 2 Tolling No.2 Pty Ltd","QGC Train 2 Tolling Pty Ltd","QPM Energy (MGP Upstream) Pty Ltd (Administrators Appointed)","QPM Energy Markets Pty Ltd (Administrators Appointed)","Qenos Pty Ltd (Administrators Appointed)","Queensland Alumina Limited","Queensland Bulk Water Supply Authority","Queensland Competition Authority","Queensland Electricity Transmission Corporation","Queensland Electricity Transmission Corporation Ltd (Powerlink Queensland)","Queensland Power Trading Corporation","RATCH-Australia Collinsville Pty Ltd & RATCH-Australia Collinsville BV","RESI Power Pty Ltd","RMB Australia Limited","RMS Utilities Pty Ltd","ROAM Consulting Pty Ltd","RTA Yarwun Pty Ltd","RWE Renewables Energy Marketing Australia Pty Ltd","RWE Supply & Trading GmbH","Radian Holdings Pty Ltd","ReAmped Energy Pty Ltd","Red Dolphin Energy Pty Ltd","Red Dolphin Systems Pty Ltd","Red Energy Pty Limited","Red Sky Energy (NT) Pty Ltd","Redbank Project Pty Limited","Renew Power Group Pty Ltd","Renewable Power Australia Limited","Reposit Power Pty Ltd","Rio Tinto Aluminium (Bell Bay) Limited","Rocky Point Power Project Pty Ltd","Ross River Operations Pty Ltd As The Trustee For The Ross River Operations Trust","Royalla Solar 2 Pty Ltd","Rye Park Renewable Energy Pty Ltd ATF Rye Park Wind Farm Trust","SA Power Networks","SA ROLR","SA Water Corporation","SG Australia Limited","SGH Energy VICP54 Pty Ltd","Salt Creek Wind Farm Pty Ltd","Santos CSG Pty Ltd","Santos Direct Pty Ltd","Santos GLNG Pty Ltd","Santos Limited","Santos NSW (Narrabri Power) Pty Ltd","Santos QNT Pty Ltd","Santos Toga Pty Ltd","Savant Energy Power Networks Pty Ltd","SavvyPlus Energy Pty Ltd As Trustee For Savvyplus Energy Trust","Schneider Electric Sustainability Business Australia Pty Ltd","Sebastopol Asset Co Pty Ltd As Trustee For The Sebastopol Asset Trust","Secure Energy Pty Ltd","Secure Meters (Australia) Pty Ltd","Senex Assets Pty Ltd","Shell Energy Australia Pty Ltd","Shell Energy Cps Pty Ltd","Shell Energy Retail Finance Pty Ltd","Shell Energy Retail Pty Ltd","Shell New Energies Australia Pty Ltd","Shoalhaven Starches Pty Ltd","Silver Asset Services Pty Ltd","Sithe Australia Power Services Pty Ltd","Skilltech Consulting Services Pty Ltd","Sleiman Trading Pty Ltd","Smart Energy Retail Pty Ltd","Smithfield Power Generation Pty Ltd","Snowtown Wind Farm Pty Ltd","Snowtown Wind Farm Stage 2 Pty Ltd","Snowy Hydro Limited","Social Energy Australia Pty Ltd (In Liquidation)","Societe Generale","Solstice Energy Retail Pty Ltd","Sonnen Australia Pty Limited","South Australian Water Corporation","South East Australia Gas Pty Ltd","South East Qld Elect Corporation Ltd (Energex - MDA)","South Street Energy Pty Ltd","South West Power","South West Queensland Electricity Corporation Ltd (Southwest Power)","Southern Natural Gas Development Pty Ltd","Spotless Advanced Metering","Spotless Facility Services Pty Ltd","Stanwell Corporation Limited","Starfish Hill Wind Farm Pty Ltd","State Electricity Commission (Vic)","Stockyard Hill Wind Farm Pty Ltd","Strategic Gas Market Trading Pty Ltd","Sumo Gas Pty Ltd","Sumo Power","Sun Metals Corporation Pty Ltd","Sun Retail Pty Ltd","Sunraysia Solar Project Pty Ltd As Trustee For Sunraysia Solar Project Trust","Suntop SF Pty Ltd As Trustee For The Suntop Asset Trust","Sustainable Business Energy Solutions Pty Ltd","Sustainable Savings Pty Ltd","Synergen Power Pty Limited","TFS Australia Pty. Limited","Tailem Bend II Project Company Pty Ltd ATF Tailem Bend II Project Trust","Tamboran Resources Pty Ltd","Tarac Technologies Pty Ltd","Taralga Wind Farm Nominees No 2 Pty Ltd (ATF Taralga Wind Farm Operating Trust)","Tarong Energy Corporation Limited","Tasmanian Gas Pipeline Pty Ltd","Tasmanian Irrigation Pty Ltd","Tasmanian Networks Pty Ltd","Telstra Energy (Generation) Pty Ltd","Telstra Energy (Retail) Pty Ltd","Tesla Motors Australia Pty Ltd","The Australian Steel Company (Operations) Pty Ltd","The Electricity Reform Unit - Energy Division - Department of Mines and Energy","The Trustee For Finley Solar Trust","The Trustee For Granville Harbour Operations Trust","The Trustee For The Active Utilities (Holding) Unit Trust","The Trustee For The SWF1 Operations Trust","The Trustee For The Trans Tasman Energy Group Trust","The University Of Adelaide","The University Of Queensland","Tibra Trading Pty Ltd","Tilt Renewables Retail Pty Ltd","Tomago Aluminium Company Pty Ltd","Toora Wind Farm Pty Ltd","Total GLNG Australia","TotalEnergies Gas & Power Asia Private Limited","TotalEnergies Gas & Power Australia Pty Ltd","TransGrid (MDA)","Transmission Operations (Australia) 2 Pty Ltd","Transmission Operations (Australia) Pty Ltd","Tri-Star Petroleum Company","United Energy Distribution Pty Limited","United Energy Distribution Pty Ltd","United Energy Ltd","United Marketing Group","Urth Energy Pty Ltd (Administrators Appointed)","VIOTAS Australia Pty Ltd","VRT TEK Pty Ltd","Valley Power Pty Ltd","Vector International Pacific Pty Ltd As Trustee For The Meehan Family Trust","Vellocet Clean Energy Pty Ltd","Vena Energy Services (Australia) Pty Ltd","Veolia Energy (ANZ) Pty Ltd","Veolia Environmental Services (Australia) Pty Ltd","Victoria Police","Victoria Power Networks Pty Ltd","Victorian Power Exchange Pty Ltd","Vintage Energy Ltd","Visy Industries Australia Pty Ltd","Visy Paper Pty Ltd As The Trustee For Southern Paper Converters Trust","Viva Energy Refining Pty Ltd","Vivienne Court Trading Pty Ltd","Voltio Pty Ltd","W.H. Heck & Sons Proprietary Limited","WEPROG","WHOLESALE POOL NSW","WHOLESALE POOL QLD","WHOLESALE POOL SA","WHOLESALE POOL SNOWY","WHOLESALE POOL TAS","WHOLESALE POOL VIC","WINconnect Pty Ltd","Wagga Wagga Operationsco Pty Ltd Atf Wagga Wagga Operations Trust","Walloons Coal Seam Gas Company Pty Limited","Waterloo Wind Farm Pty Ltd","Wattle Point Wind Farm Pty Ltd","Watts Energy","Wellington North Solar Farm Pty Limited","Wemen Asset Co Pty Ltd As Trustee For Wemen Solar Unit Trust","WesTrac Pty Ltd","West Wyalong Fund Pty Ltd As The Trustee For West Wyalong Trust","Western Downs Green Power Hub Pty Ltd ATF Western Downs Green Power Hub Trust","Weston Aluminium Pty Limited","Weston Energy Pty Ltd","Westpac Banking Corporation","Westside CSG A Pty Ltd","Westside CSG D Pty Ltd","Westside Corporation Limited","White Rock Wind Farm Pty Ltd","Whitsunday Solar Farm Pty Ltd","Wide Bay Burnett Electricity Corporation Ltd","Wide Bay Burnett Electricity Corporation Ltd (DNSP)","Wide Bay Burnett Electricity Corporation Ltd (MDA)","Wild Cattle Hill Pty Ltd","Willogoleche Power Pty Ltd As The Trustee For The Willogoleche Operating Trust","Wilmar Sugar Pty Ltd","Windy Hill Wind Farm Pty Ltd","Winton Asset Co Pty Ltd As The Trustee For Winton Asset Trust","Wirtgen Energy Glenrowan Pty Ltd","Woodlawn Wind Pty Ltd","Woodside Energy (Bass Strait) Pty Ltd","Woolooga Fund Pty Ltd As Trustee For The Woolooga Trust","Wyalong Solar Farm Pty Ltd ATF Wyalong Solar Farm Unit Trust","X-ELIO Blue Grass Pty Ltd","Y.E.S. (Aust) Pty Ltd","Y.E.S. Energy (SA) Pty Ltd","Yadlamalka Energy Pty Ltd ATF The Yadlamalka Energy Trust","Yamasa Australia Pty Ltd","Yarranlea Solar Pty Ltd","Yatpool Sun Farm Pty Ltd","Yurika Pty Ltd","Zen Energy Retail Pty Ltd (Liquidators Appointed)","Zinifex Port Pirie Pty Ltd","pdView Pty Ltd"]},"PARTICIPANTCLASSID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Class of participant","examples":["MARKET PARTICIPANT","NONMARKET","POOL PARTICIPANT","SPECIAL PARTICIPANT"]},"PRIMARYBUSINESS":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Identifies primary business activity of participant","examples":["Auction Trader","BANKING","Bank","Bank - Trader","Banking - Reallocator","Controller / Operator / Intermediary","Customer","Customer / Generator","Data Access","Develop Energy Software Systems","Energy","Energy Development","Financial","GENERATOR","Gas Market","Gas Participant","Generator","Generator - Wind Farm","Government - Data Provider","Government Business","Government Department","Intemediary For Generator","Local Network Operator","MARKET CUSTOMER","MDA","MNS Generators","Market Customer","Market Customer -","Market Customer - Commercial /Industrial","Market Customer - Load Dispatch","Market Customer - Load Non-dispatch","Meter Data Provider","Metering","Metering Service Provider","NEM RLR","NSP","NSP + Mining","Non-scheduled Non-market Generator","Ombudsman - Government Department","Public Data Feed","Purchaser & NSW Gov Reform","QLD STTM","Reserve Trading","Retail","Retail / Generator / Nsp","Retail Customer","Retailer","Retailer / Generator","Retailer Of Last Resort","Retailing","Retailing electricity","Rio Tinto","SRA Trader","STTM - QLD","STTM QLD","STTM QLD Information Provider","Scheduled Market Generator","TRADER","Trader","WIND FARM","Wind Farm"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Not used","examples":["2nd participant id for Attunga Capital Pty Ltd","AEMO Interface to the WEB via Walter Muller","Adding Mkt Customer","Citipower","Correcting Austraclear account","Country Energy","Country Energy ","DEFAULT LOCAL RETAILER FOR WHOLESALE","DEFAULT LOCAL RETAILER FOR WHOLSALE","Data Provider only","ERM Power 2 Pty + Arrow (Southern Generation) Pty Ltd","Entry for Captial WF M/NS","Gas Participant","Inital registration for Waubra WF","Initial Entry for Sth Bank Institue","Interface to NEMMCO web site","Meter Service Provider","Name change","OPTIMA Energy Retail","Ombudsman","Ombudsman - Government department","Re Badging for AEMO","Removing from MMS per 2006 registration.","Required for Reports","Select Data and Measurement Solutions","Special data access","Trader","Transition to AEMO 1/7/2009","Update address as per Settlement request","Westpac Banking Corporation","etc","had userid which no longer exists.","update the Austraclear code"],"unused":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PARTICIPANT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":28679,"decompressed_size_all_time":26820880},"visibility":"Public","trigger":"When new participants register or existing participants details are changed"},"PARTICIPANTACCOUNT":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANTACCOUNT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#124"],"comment":"PARTICIPANTACCOUNT shows financial details on participants.","description":"PARTICIPANTACCOUNT data is confidential to the relevant participant.\n\nSource\n\nPARTICIPANTACCOUNT updates as new participants register or existing\nparticipants change details.","primary_keys":["PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"ABN":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Australian Business Number"},"ACCOUNTNAME":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Name of the account"},"ACCOUNTNUMBER":{"sql_type":"VARCHAR2(16)","pl_type":"str","mandatory":false,"comment":"Account number"},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"BANKNAME":{"sql_type":"VARCHAR2(16)","pl_type":"str","mandatory":false,"comment":"Bank name"},"BANKNUMBER":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Bank number","is_integer":true,"num_int_bits":64},"BRANCHNAME":{"sql_type":"VARCHAR2(16)","pl_type":"str","mandatory":false,"comment":"Branch name"},"BRANCHNUMBER":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Branch number","is_integer":true,"num_int_bits":64},"BSBNUMBER":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"BSB number"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEMMCOCREDITACCOUNTNUMBER":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"AEMO credit account number","is_integer":true,"num_int_bits":64},"NEMMCODEBITACCOUNTNUMBER":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"AEMO debit account number","is_integer":true,"num_int_bits":64}},"visibility":"Private","trigger":"When new participants register or existing participants details are changed"},"PARTICIPANTCATEGORY":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANTCATEGORY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#133"],"comment":"PARTICIPANTCATEGORY sets out valid participant categories.","description":"PARTICIPANTCATEGORY is public data, so is available to all participants.\n\nSource\n\nPARTICIPANTCATEGORY updates as categories change. PARTICIPANTCATEGORY\nchanges infrequently.","primary_keys":["PARTICIPANTCATEGORYID"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Participant category identifier","examples":["B2B_ACCRED","CUSTOMER","DATAACCESS","DISTOP","DNSP","DRSP","EMBNETMAN","GAS","GENERATOR","INTERNAL","IRP","MASP","MDA","MDP","METERCOORD","MNSP","MPB","MPC","MSRP","NMISP","NONCODE","NSP","REALLOCATR","RERT","SMALL_GEN","SSMSERVICE","TNSP","TRADER","TRANSOP"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Category description","examples":["B2B Accredited Participant","Customer","Data Access Participant","Demand Response Service Provider","Distribution Network Service Provider","Distribution Operator","Embedded Network Manager","Gas Market Participant","Generator","Improving Security Frameworks (ISF)","Integrated Resource Provider","Internal - NEMMCO only","Market Ancillary Service Provider","Market Network Service Provider","Market SAPS Resource Provider","Meter Data Provider","Meter Provider Type B","Meter Provider Type C","Metering Co-ordinator","Metering Data Agent","NMI Service Provider","Network Service Provider","Non-Code Participant","Reallocator","Reserve Trader","SRA Settlement Residue Trader","Small Generator Aggregator","Transmission Network Operator","Transmission Network Service Provider"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:11:13"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PARTICIPANTCATEGORY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1112,"decompressed_size_all_time":1321180},"visibility":"Public","trigger":"When categories change"},"PARTICIPANTCATEGORYALLOC":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANTCATEGORYALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#142"],"comment":"PARTICIPANTCATEGORYALLOC sets out the assignment of participants to particular categories.","description":"PARTICIPANTCATEGORYALLOC data is public, so is available to all\nparticipants.\n\nSource\n\nPARTICIPANTCATEGORYALLOC updates for new participants or when categories\nchange. PARTICIPANTCATEGORYALLOC changes infrequently.","primary_keys":["PARTICIPANTCATEGORYID","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Category unique identifier","examples":["B2B_ACCRED","CUSTOMER","DISTOP","DNSP","DRSP","EMBNETMAN","GAS","GENERATOR","INTERNAL","MASP","MDA","MDP","METERCOORD","MNSP","MPB","MPC","MSRP","NONCODE","NSP","REALLOCATR","RERT","SMALL_GEN","TNSP","TRADER","TRANSOP"]},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","examples":["ACACIRET","ACACISGA","ACC","ACCELER","ACENERGY","ACTEWAGL","ACTEWMP","ACTEWNGY","ACTEWNWO","ACTEWP","ACTIONM","ACTIONMC","ACTIONMP","ACTIVENM","ACTIVMC","ACTIVMP","ACUMEMDP","ACUMENMP","ADCHEM","ADVANCE","ADVANCEM","ADVANCEP","AEMC","AEMOLNGR","AEMOWEB1","AER","AES","AETVPOWR","AGGREKRT","AGILITYM","AGITNAMI","AGLAM","AGLE","AGLENRGY","AGLESM","AGLESRT","AGLGASST","AGLPARFQ","AGLPARFW","AGLQLD1","AGLQLD2","AGLSHYDR","AGLSQLD","AGLUPSTR","AGLWBESS","AGLWG","AGLWGSA","AGORARET","ALCOA","ALCOAPA","ALCOAPRT","ALN","ALNTABUS","ALNTACEA","ALNTARES","ALNTBHWF","ALSAWCAI","ALSAWSME","AMALMASP","AMAYSIM","AMBERELC","AMPOLCNI","AMPOLNRG","AMPOLWST","ANZ","APLNG","APSUSGA","APTALLG","APTAMHLD","APTPETRO","APTPIPE","AQUILA","ARARATWF","ARCADIA","ARMOURE","ARROW","ARRWTPT2","ARRWTPTN","ASTEELRT","ATTUNGA2","ATTUNGAC","AUPACLNG","AUROLR","AURORA","AURORAD","AURORAMP","AURORAP","AUSGASTR","AUSGSAPS","AUSPG","AUSPGNSW","AUSPIPE","AUSTINL","AUSTINLP","B2PS","BALANCE","BALANSGA","BALBESS","BANGOWF2","BARCAPAU","BASSLINK","BBPEM","BBPOWER","BEACHE","BERBANK","BERBANKW","BERYBKWF","BGCPART","BHPBPVIC","BHPPETRL","BLUENGY","BLUESCOP","BLUESCRT","BOCLTD","BOCLTDRT","BOCOROCK","BODWF1","BOMENSF","BORAL","BORALCMT","BOULBESS","BOWCSGPT","BOYNERT","BPAUS","BPENGAUS","BPSING","BRICKWRK","BRIGHTEN","BRIGHTON","BRIGHTSP","BULGANA","BWFTRUST","CAPBESS","CAPELEC","CAPNSP","CAPTPL","CATHROCK","CAYMAN","CBA","CHALLHWF","CHERRYWF","CHFOURPT","CHOICENM","CITIP","CITIPP","CITIPWMP","CITYFIN","CLARESF1","CLEAN","CLEANCO","CLEANCOG","CLEANTEC","CLEMGPWF","CLERMSF","CLICK","CMC","CNRGY","CNRGYMPB","CNRGYP","CNTRLPET","CNTURION","COALCO","COLEAMSF","COLLECWF","COLTSGA","COLUMSF","COMET","COMO","COMSTEEL","CONCOCOP","CONTACTA","COOGEE","COOPER","COOPERCH","COOPERMS","COOPERS","COROWASF","COZERO","COZEROER","CPERENM","CPNETMDP","CQPCAP","CREATIVE","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CSR","CSRETAIL","CSVCDROM","CULLRGWF","CUMMINS","DALRYMPN","DANSKECA","DARLPSF","DARLSF","DAYDSF","DEATM","DEIBDL","DELTA","DELTAWST","DENISON","DEPTINDY","DEUREKA","DEUTSCHE","DIAMDGEN","DIAMDSGA","DIAMOND","DIAPURWF","DIRLINKP","DISAMAUS","DISCOVER","DMSMP","DODO","DOWJONES","DPESS","DPNTBESS","DUBBONA","DUBBOSK","DULACCA","DUNDWF","EAECOGEN","EAGENID","EAINTMDY","EARETALT","EARETID","EASTENGY","EASTENM","EASTERN","EASTHALL","EASTSGA","EATALLA","EAXENM","EDENVALE","EDGECAPT","EDIFYEN","EDISON","EDLCSMQ","EDLGPSGA","EDLGRPOP","EDLLFGN","EDLLFGV","EDLNGD","EDLOCI","EDLTT","EEMA","EEQ","EEQGEN","EEQLILY","EEQMEWF","EEUS","EIABVIR","EINABOX","EIOSA","ELASSETS","ELECTDSM","ELETRADE","ELEXSGA","ELYSIANE","EMPRENGY","ENCAP","ENDEAVRT","ENELAUS","ENELRET","ENERBRIX","ENERGEX","ENERGEXP","ENERGNSP","ENERGXMP","ENERGYAP","ENERVEMP","ENERVENM","ENFOCENM","ENGYAUST","ENGYAVIC","ENGYLOC","ENGYLOC3","ENGYTIME","ENIAUSBV","ENMSOENM","ENOCMASP","ENOCRT","ENOCSGA","ENOVAENG","ENRGYLIM","ENRGYONE","ENRON","ENRONAFT","ENSERVMG","ENVESTRA","EONENM","EOQLD","EPCSGA","EPCTECH","EPHOSGA","EPIC","EPMENM","EPOCHNGY","EPVIC1","ERCENM","ERGON","ERGONETP","ERMGEN","ERMPOWER","ERMPOWRT","ESC","ESNRGY","ESSENTRT","ESSOAURT","ESSOAUS","ESTRNSUP","ETEX","ETSACOR","ETSAMDP","ETSAP","ETSAPMP","ETSAPP","ETSAPR","ETSAPVIC","ETSATM","ETSATP","ETSAUTIL","EVERGEN","EVERGETP","EWONSW","EWOVIC","FALCONAU","FERGUSWF","FERRIER","FEX","FINLEYSF","FIRMMASP","FIRSTNRG","FLOENRGY","FNQEB","FONTERRA","FPC30","FRVROYAL","GALILEE","GANNBESS","GANNDNSP","GANNSF","GBENERGY","GEEPOWER","GLENROSF","GLENSF","GLOBIRD","GLOPOOL","GOENGSGA","GOON","GPUPNMP","GPUPP","GR","GRANHAWF","GRDSHRE","GREENSP","GRIFFITH","GROUPNRG","GRSTHNGY","GSFM","GSOUTHM","GSOUTHP","GSPOWER","GSWF1A","GSWF1B","GUNNEDAH","GUNNING","HAAST","HAMISF","HARTREE","HAUGHTSF","HAYMSF","HAZELPWR","HBESS","HELPDESK","HESI","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HUGSF","HUMENM","HWF3","HYDROPWR","HYDROSA","HYDROTAS","ICAPAUST","ICAPBROK","ICRC","IEQLD","IERS","IHUBENM","IHUBMDP","IHUBMPB","IMCPAC","INCITECP","INFIGENH","INFISAGT","INFRATIL","INNOGYEN","INTEGM","INTEGMP","INTEGP","INTELENM","INTLENCU","INTLENGY","IONAOPS","IPENERGY","ITPDSGA","JAKGREEN","JEMASF","JENMDP","JMNAEGP1","JMNANGP","JMNAVICH","JPAENRGY","KABANWF","KARIT","KARSF","KENNEDYE","KIATAPRJ","KIDSTON","KINETIK","KLEENHT","KOGAGLNG","LALLALWF","LANDFILL","LATTICEN","LBWPLB2","LDHENRGY","LIBERTY","LIFETRAD","LIGHTSRC","LINGAPWF","LIQUIDET","LKBWFBES","LKBWIND","LMSENE","LMSGEN","LOCALENM","LOCALVOL","LONGSGA","LONSDALE","LOYBPSOM","LOYYANGA","M2ENERGY","MACARTHR","MACBANK","MACKAY","MACKAYS","MACQGEN","MANNUMS2","MBAHNTH","MBUTCHER","MDYENM","MDYMC","MDYMDP","MDYMP","MEBP","MELBWATR","MERCOMAS","MERIDIAN","MERIDSGA","METPL","METROMC","METZSF","MFTENRGY","MGPENM","MICHELLW","MICROGRD","MITSUIEP","MKTSORCE","MNCNSP","MOBILOIL","MOLONGOP","MOLYCOP","MOMENM","MOMENTUM","MONDO","MOREEAC","MOREESF","MORGANCG","MORTLSWF","MOUSF","MRYLINK1","MSATS","MTAENRGY","MTGELLWF","MTMERCER","MTMILLAR","MULTINET","MWARRA","MYENM","MYMC","NAGMO","NARRABRI","NECA","NECTR","NEMALERT","NEMITWEB","NEMITWEB1","NEMITWEB2","NEMMCO","NEMPMONNI","NEMRESTR","NEWENGSF","NEWGEN","NEWGRWF","NEXTBE","NEXTSGA","NORPOWER","NORQEB","NORQEBP","NORSKOG","NORSPMRT","NORTHPM","NORTHPP","NOVAPWR","NOWDRU","NPMONN","NPMONQ","NPSAIL","NRSO","NSWEPL","NSWLUMO","NUMURKSF","NVTSF","NYRSTAR","OCEANIA","OCNSP","OES","OESR","OMFINANC","ONENERGY","ONESTCC","ONESTLRT","ONESTM","ONESTNRT","ONESTNSW","ONLINEPG","OPALPAPR","OPALRT","OPTIMA","OPTIVER","ORER","ORICA","ORIGINER","ORIGINLP","ORIGINMC","ORIGINRT","ORIGINUS","ORIGINV","ORIGNENM","ORORA","OVOENGY","OVOKALU","OZGRPL","PACBLUE","PACHYDIN","PACPOWER","PACTRAD","PAPERART","PAPERAUS","PAPLGLNG","PAPMICRO","PBLUESGA","PDVIEW","PEAKCO","PETROCNI","PEVHSGA","PHOTNSGA","PHRETAIL","PINNOVRT","PLDENRGY","PLINKMP","PLINKP","POOLEDEN","POOLNSW","POOLQLD","POOLSNOW","POOLTAS","POOLVIC","PORTADL","POWCP","POWERCMP","POWERL","POWERMDP","POWGEN","POWMEMDP","POWMETMC","POWMETMP","POWRCLUB","POWRSHOP","POWRSHRT","PROGREEN","PROGRSGA","PRTDBSQL","PSF","PULSE","PWRWATER","PYRENEES","PZESURAT","QALUMINA","QCLNGOPC","QENERGY","QENOS","QGCLMTD","QGCSALE1","QGCTOLL","QGCTOLL2","QLDLUMO","QLDRSO","QPMENGY","QPMMGP","QTPTC","QTSC","RADIAN","RADIANHO","RATCHAC","REAMPED","REAMPED2","REDBANK","REDDOLPH","REDDOLTP","REDSKYNT","RENEWSGA","REPOSTRT","RESPONSE","RIOTALBB","RIVEBESS","RMBAUST","RMSENM","ROCKYPT","ROSSRVER","RWEASIAP","RWESUPPL","SADTEI","SAEPL","SALTCRK","SANCTMBC","SANTOCSG","SANTOS","SANTOSD","SANTOSTO","SAPHWF1","SAPNRT","SAS17ENM","SAVPP1","SAVVYPE","SAWATER","SAWC","SAWCML","SAWCRT","SAWCSGA","SEBSF","SECURENG","SECURMDP","SECV","SENEXAST","SERDR","SGAUSLT","SGAUST","SGHENRGY","SGMTRADE","SHELLEA","SHELLNEW","SHOAL","SHUBMASP","SITHE","SLEIMAN","SMARTEST","SMARTSGA","SMCTSV","SMORGON","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWTRAD","SNOWY","SNOWYNRG","SNOWYP","SNOWYSC1","SNOWYSC2","SNOWYSC3","SNOWYSC4","SOCIALEA","SOLARIS","SOLARISP","SOLARMP","SONNEN","SONNMASP","SOUTHHYD","SOUTHNGD","SOUTHWP","SOUTHYD2","SPANMDP","SPAUSNET","SPTLSSMC","SPTLSSMP","SQWTRSGA","SRSF1","SSENM","STANCEA","STANRET","STANWELL","STATEGAS","STHSTSGA","STHWESTP","STHYDSGA","STOCKYRD","SUCROGEN","SUMOPOWR","SUNTOP","SYTHE","TAILEM","TANGO","TARONG","TASGAS","TASIRRIG","TASPIPE","TBLANDGP","TBSOL","TCAMP","TCAUSTM","TELSTRA","TELSTRAE","TELSTRAR","TELSTSGA","TESLAMRT","TFSAUS","TGSERVP","TIBELE01","TILTSGA","TIPSCO","TOA","TOA2","TOMAGOAC","TOMAGORT","TOTAGLNG","TOTALGP","TRANSEND","TRANSGBH","TRANSGM","TRANSGMP","TRANSGP","TRISTAR","TRUDW","TTEGEENM","TYCOWATR","UMPLP","UNIOFQLD","UNITED","UNITEDDP","UNITEDEN","UNITEDMP","UNITEDRT","URANQNTY","URTH","VECTORMC","VECTORMP","VELOCSGA","VEPL","VICBAT","VICGASDB","VICLUMO","VICPNRT","VICPOL","VINTAGE","VIOTAS","VIOTASRT","VISYPAPR","VIVAENRT","VIVCOUR2","VIVCOURT","VOLTENM","VPX","VPXP","VRTSYSMC","VRTTEKMC","VWATT","WAGGAOPS","WALGBESS","WALLOONS","WANDOAN","WATERLWF","WATTSENM","WBAYM","WBBEBP","WDOWNS","WELLNTH","WEMENSF","WEPROG","WERADUNI","WERCSIRO","WESTON","WESTPAC","WESTSDEA","WESTSDED","WGWF","WHECKSON","WIDEBAYB","WILDCATL","WINENM","WINRET","WINRETCC","WINRETWF","WINTONSF","WONTHGWF","WOOLOOGA","WPWF","WSTRACRT","WSUNDAY","WYALONG","XELIO","YALLNR","YALLOURN","YALSTHWF","YARRANSF","YARWUN","YARWUNRT","YATESSGA","YDMKSGA","YESSASGA","YURIKART","ZENENRGY","ZINIFEX"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:01:23"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PARTICIPANTCATEGORYALLOC%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":19918,"decompressed_size_all_time":18322280},"visibility":"Public","trigger":"Updates for new participants or when categories change"},"PARTICIPANTCLASS":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANTCLASS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#151"],"comment":"PARTICIPANTCLASS sets out valid participant classifications.","description":"PARTICIPANTCLASS data is public, so is available to all participants.\n\nSource\n\nPARTICIPANTCLASS updates only if classifications change. This table\nchanges infrequently.","primary_keys":["PARTICIPANTCLASSID"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTCLASSID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Class of participant","examples":["MARKET PARTICIPANT","NONMARKET","POOL PARTICIPANT","SPECIAL PARTICIPANT"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Description of participant class","examples":["Market participant","Non Market Participant","Pool Participant","Special Participant"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/06/30 22:01:24"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PARTICIPANTCLASS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":481,"decompressed_size_all_time":631830},"visibility":"Public","trigger":"When classifications change"},"PARTICIPANTCREDITDETAIL":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PARTICIPANTCREDITDETAIL","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#160"],"comment":"","description":"PARTICIPANTCREDITDETAIL data is confidential to each participant.\n\nSource\n\nPARTICIPANTCREDITDETAIL updates infrequently.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID"],"indexes":[["PARTICIPANTID"],["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"is_categorical":true},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CREDITLIMIT":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"is_integer":true,"num_int_bits":64},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When participant credit details are created or updated"},"PARTICIPANTNOTICETRK":{"package":"MARKET_NOTICE","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_NOTICE","REPORT_SUB_TYPE":"PARTICIPANTNOTICETRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec35.htm#19"],"comment":"PARTICIPANTNOTICETRK provides the cross-reference between participant market notices and participants.","description":"PARTICIPANTNOTICETRK data is Confidential to the relevant participant.\n\nSource\n\nPARTICIPANTNOTICETRK updates immediately, whenever a participant notice\nis issued.","primary_keys":["NOTICEID","PARTICIPANTID"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"NOTICEID":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Market notice identifier","is_integer":true,"num_int_bits":64},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When a participant notice is issued"},"PARTICIPANT_BANDFEE_ALLOC":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"PARTICIPANT_BANDFEE_ALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#67"],"comment":"PARTICIPANT_BANDFEE_ALLOC shows the market fee for each Participant/Participant Category over time.","description":"Source\n\nThis view updates only on change of participant configuration.","primary_keys":["EFFECTIVEDATE","MARKETFEEID","PARTICIPANTCATEGORYID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date on which this data becomes effective.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Identifier for Market Fee"},"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"The participant category that the market fee recovery amount pertains to."},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Period identifier","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The value of this market fee","is_float":true}},"visibility":"Private","trigger":"When there is a participant configuration change"},"PASACASESOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#807"],"comment":"PASACASESOLUTION sets out ST PASA case listing providing details of each STPASA case run.","description":"PASACASESOLUTION is obsolete on 27 March 2002\n\nPASACASESOLUTION is public data, so is available to all participants.\n\nSource\n\nPASACASESOLUTION is not used; was updated every 2 hours.","unused":true,"primary_keys":["CASEID"],"indexes":[["LASTCHANGED"]],"columns":{"CASEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Case Identifier"},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Scheduled date and time of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEFICITCAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Boolean","mandatory":false,"comment":"Deficit capacity detected flag","is_boolean":true},"EXCESSGENERATION":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Boolean","mandatory":false,"comment":"Excess generation detected flag","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PASAVERSION":{"sql_type":"NUMBER(27,10)","pl_type":"pl.Float64","mandatory":false,"comment":"Software version identifier","is_float":true},"SOLUTIONCOMPLETE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Public"},"PASACONSTRAINTSOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#816"],"comment":"PASACONSTRAINTSOLUTION records the latest binding STPASA constraint details for each period. For each solution, the latest recalculation for each period overwrites the previous entry.","description":"PASACONSTRAINTSOLUTION is obsolete on 27 March 2002\n\nPASACONSTRAINTSOLUTION is public data, so is available to all\nparticipants.\n\nSource\n\nPASACONSTRAINTSOLUTION is not used; was updated every 2 hours.","unused":true,"primary_keys":["CONSTRAINTID","PERIODID"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint Id","is_categorical":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Interval (48 half hours)","num_int_bits":16},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Binding value of capacity and adequacy (if insufficient to measure)","is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Deficit MW of surplus capacity","is_float":true},"CASEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Case Identifier"},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time of the end of the period","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXCESSGENMARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Binding value of dispatch generator above aggregate self dispatch","is_float":true},"EXCESSGENVIOLATIONDEGREE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Deficit of generator above aggregate self dispatch level","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public"},"PASAINTERCONNECTORSOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#825"],"comment":"PASAINTERCONNECTORSOLUTION records ST PASA interconnector solutions for the latest period.","description":"PASAINTERCONNECTORSOLUTION is obsolete on 27 March 2002\n\nPASAINTERCONNECTORSOLUTION is public data, so is available to all\nparticipants.\n\nSource\n\nPASAINTERCONNECTORSOLUTION is unused; was updated every 2 hours.","unused":true,"primary_keys":["INTERCONNECTORID","PERIODID"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Id","is_categorical":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Interval (48 half hours)","num_int_bits":16},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal value in capacity","is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity MW flow","is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation value in capacity","is_float":true},"CASEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Case Identifier"},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time of the end of the period","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXCESSGENMARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal value in excess generation","is_float":true},"EXCESSGENMWFLOW":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess generation MW flow","is_float":true},"EXCESSGENVIOLATIONDEGREE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation value in excess generation","is_float":true},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit","is_float":true},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public"},"PASAREGIONSOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#834"],"comment":"PASAREGIONSOLUTION shows the Regional solution for ST PASA showing reserves for each half-hour period. This table (PASAREGIONSOLUTION_D) shows the latest calculated result for each period.","description":"PASAREGIONSOLUTION is obsolete on 27 March 2002.\n\nPASAREGIONSOLUTION is public data, so is available to all participants.\n\nSource\n\nPASAREGIONSOLUTION is not used; was updated every 2 hours.","unused":true,"primary_keys":["PERIODID","REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Interval (48 half hours)","num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"CAPACITYREQUIRED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Trading interval demand for the region that has a 10% probability of being exceeded, plus the medium term capacity reserve standard.","is_float":true},"CAPACITYSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Surplus capacity","is_float":true},"CASEID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PASA Case Identifier"},"CONSTRAINEDCAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained capacity","is_float":true},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time of the end of the period","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEMAND10":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"10% exceedence forecast","is_float":true},"DEMAND50":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"50% exceedence forecast","is_float":true},"DEMAND90":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"90% exceedence forecast","is_float":true},"ENERGYREQUIRED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total amount of energy required for the reported day","is_float":true},"EXCESSGENERATION":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Excess generation in period OR Deficit generation if VoLL","is_integer":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOADREJECTIONRESERVEREQ":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Load rejection reserve requirement","is_float":true},"LOADREJECTIONRESERVESURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Load rejection reserve surplus","is_float":true},"NETINTERCHANGEUNDEREXCESS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interchange excess","is_float":true},"NETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interchange scarcity","is_float":true},"RESERVECONDITION":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve condition","is_float":true},"RESERVEREQ":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve requirement","is_float":true},"RESERVESURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve surplus","is_float":true},"UNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained capacity","is_float":true}},"visibility":"Public"},"PASA_CONTINGENCY_DEFINITION":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"GENERIC_CONSTRAINT","REPORT_SUB_TYPE":"PASA_CONTINGENCY_DEFINITION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#72"],"comment":"PASA_CONTINGENCY_DEFINITION shows the contingency details used by PD and ST PASA.","primary_keys":["CONTINGENCYID","EFFECTIVEDATE","VERSIONNO"],"columns":{"CONTINGENCYID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The contingency identifier"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The effective date for this contingency","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTINGENCYDESCRIPTION":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"The description for this contingency"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"On Change"},"PASA_DUID_SUBSTATION_MAPPING":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_DUID_SUBSTATION_MAPPING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#171"],"comment":"PASA_DUID_SUBSTATION_MAPPING shows the mapping of each DUID to its Energy Management System Substation ID","primary_keys":["DUID","EFFECTIVEDATE","SUBSTATIONID","VERSIONNO"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this DUID to Substation ID mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SUBSTATIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The Energy Management System identifier of the Substation to which this DUID belongs"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"}},"visibility":"Public","trigger":"On Change"},"PASA_INTERCONNECTOR_BOUNDARY":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_INTERCONNECTOR_BOUNDARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#177"],"comment":"PASA_INTERCONNECTOR_BOUNDARY shows the mapping of each Interconnector boundary to its constituent Energy Management System Branch IDs","primary_keys":["BRANCHID","BRANCHSUBID","EFFECTIVEDATE","INTERCONNECTORID","VERSIONNO"],"columns":{"BRANCHID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"Branch Identifier"},"BRANCHSUBID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"Branch Sub-Identifier"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this Interconnector Boundary mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The identifier of the Interconnector","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BRANCH_TO_INTERCONN_FLOWMULT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Multiplier(1 or -1) used to convert from Branch Flow direction to Interconnector flow direction","is_integer":true,"num_int_bits":8},"BRANCHFROMSUBSTATION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Branch FromSubstation. Positive BranchFlow from FromSubstation to ToSubstation."},"BRANCHTOSUBSTATION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Branch ToSubstation. Positive BranchFlow from FromSubStation to ToSubStation."},"BRANCHTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Branch Type(LN = Line, XF = Transformer, ZBR = Zero Impedance Branch)"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"}},"visibility":"Public","trigger":"On Change"},"PASA_INTERCONNECTOR_MAPPING":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_INTERCONNECTOR_MAPPING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#183"],"comment":"PASA_INTERCONNECTOR_MAPPING shows the mapping of each Interconnector to its From Region ID and To Region ID","primary_keys":["EFFECTIVEDATE","INTERCONNECTORID","VERSIONNO"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this Interconnector mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The identifier for this Interconnector","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":false,"comment":"From Region ID for this Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTOR_FULLNAME":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Full Name for this Interconnector"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"},"TOREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"To Region ID for this Interconnector"}},"visibility":"Public","trigger":"On Change"},"PASA_INTERZONAL_BOUNDARY":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_INTERZONAL_BOUNDARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#189"],"comment":"PASA_INTERZONAL_BOUNDARY shows the mapping of each Interzonal connector boundary to its constituent Energy Management System Branch IDs","primary_keys":["BRANCHID","BRANCHSUBID","EFFECTIVEDATE","INTERZONALCONNECTORID","VERSIONNO"],"columns":{"BRANCHID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"Branch Identifier"},"BRANCHSUBID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"Branch Sub-Identifier"},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this Interzonal connector boundary definition","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERZONALCONNECTORID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"The identifier for this Interzonal connector"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BRANCH_TO_INTERZONAL_FLOWMULT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Multiplier(1 or -1) used to convert from Branch Flow direction to Interzonal connector flow direction","is_integer":true,"num_int_bits":8},"BRANCHFROMSUBSTATION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Branch FromSubstation. Positive Branch Flow from FromSubstation to ToSubstation."},"BRANCHTOSUBSTATION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Branch ToSubstation. Positive Branch Flow from FromSubstation to ToSubstation."},"BRANCHTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Branch Type(LN = Line, XF = Transformer, ZBR = Zero Impedance Branch)"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"}},"visibility":"Public","trigger":"On Change"},"PASA_INTERZONAL_MAPPING":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_INTERZONAL_MAPPING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#195"],"comment":"PASA_INTERZONAL_MAPPING shows inter-zonal mapping details, including operating status.","primary_keys":["EFFECTIVEDATE","INTERZONALCONNECTORID","VERSIONNO"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this InterZonal Mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERZONALCONNECTORID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"The identifier for this Interzonal connector"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FROMZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"The From ZoneId for this Interzonal connector"},"INTERZONALCONNECTOR_FULLNAME":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Full Name for this Interzonal connector"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"},"TOZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"The To ZoneId for this Interzonal connector"}},"visibility":"Public","trigger":"On Change"},"PASA_SUBSTATION_ZONE_MAPPING":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_SUBSTATION_ZONE_MAPPING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#201"],"comment":"PASA_SUBSTATION_ZONE_MAPPING shows the mapping of each Energy Management System Substation ID to its parent Zone ID","primary_keys":["EFFECTIVEDATE","SUBSTATIONID","VERSIONNO"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this Energy Management System Substation ID to Zone ID mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SUBSTATIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"The Energy Management System identifier for this Substation"},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"The identifier of the Zone to which this Energy Management System Substation ID belongs"}},"visibility":"Public","trigger":"On Change"},"PASA_ZONE_REGION_MAPPING":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PASA_ZONE_REGION_MAPPING","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#207"],"comment":"PASA_ZONE_REGION_MAPPING shows zone to region mapping details and provide the Region Reference Zone information.","primary_keys":["EFFECTIVEDATE","VERSIONNO","ZONEID"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this Zone-Region Mapping","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the Effective date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Zone identifier"},"IS_RRN_ZONE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES or NO/<Blank>. LORCONDITION is only reported for supply deficits in a Zone that contains the Regional Reference Node"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OPERATINGSTATUS":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Active or inactive indicator"},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region in which this Zone belongs","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"visibility":"Public","trigger":"On Change"},"PD7DAY_CASESOLUTION":{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#1"],"comment":"PD7DAY case solution table","primary_keys":["RUN_DATETIME"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run.","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PD7DAY_CASESOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:12:38"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1145,"decompressed_size_all_time":3110310},"visibility":"Public","trigger":"Publishes few times per day"},"PD7DAY_CONSTRAINTSOLUTION":{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#7"],"comment":"PD7DAY constraint solution","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","INTERVENTION","RUN_DATETIME"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["C_N_NESBESS_150_G","C_N_NESBESS_150_L","C_N_QUORNP_019_L_H","C_N_QUORNP_080_G_H","C_V_GPWFWST_462","DATASNAP_DFS_LS","DATASNAP_DFS_NCAN","DATASNAP_DFS_NCWEST","DATASNAP_DFS_NNTH","DATASNAP_DFS_NSYD","DATASNAP_DFS_QCEN","DATASNAP_DFS_QCIND","DATASNAP_DFS_QFNQ","DATASNAP_DFS_QNTH","DATASNAP_DFS_QROSS","DATASNAP_DFS_QSTHE","DATASNAP_DFS_QSTHW","DATASNAP_DFS_Q_BCCP","DATASNAP_DFS_Q_BCRG","DATASNAP_DFS_Q_CLST","DATASNAP_DFS_Q_CLWU","DATASNAP_DFS_Q_LCCP","DATASNAP_DFS_Q_RGLC","DATASNAP_DFS_Q_TAMR","DATASNAP_DFS_Q_TAMR2","DATASNAP_DFS_SADL","DATASNAP_DFS_SNTH","DATASNAP_DFS_SRIV","DATASNAP_DFS_SSE","DATASNAP_DFS_SWNSW","DATASNAP_DFS_TNTH","DATASNAP_DFS_TNWEST","DATASNAP_DFS_TWCST","DATASNAP_DFS_T_FASH1","DATASNAP_DFS_T_GOCS1","DATASNAP_DFS_T_HAGT1","DATASNAP_DFS_T_PMHA1","DATASNAP_DFS_T_PMHA3","DATASNAP_DFS_T_SHGT","DATASNAP_DFS_T_SHPM","DATASNAP_DFS_T_TATU","DATASNAP_DFS_T_WALE","DATASNAP_DFS_VIC_SG","DATASNAP_DFS_VMEL","DATASNAP_DFS_V_BABE","DATASNAP_N_AR_LS_TE","DATASNAP_N_MUSW","DATASNAP_N_TAM","DATASNAP_PDID_1","DATASNAP_PDID_2","DATASNAP_PV_NSW","DATASNAP_PV_QLDCEN","DATASNAP_PV_QLDNORTH","DATASNAP_PV_QLDSOUTH","DATASNAP_PV_SA","DATASNAP_PV_TASNORTH","DATASNAP_PV_TASSOUTH","DATASNAP_PV_VIC","DATASNAP_TE_967_1","DATA_MMS_ALERT1","DSNAP_BU_PST1_TAP","DSNAP_BU_PST2_TAP","DSNAP_BU_PST3_ANG","DSNAP_BU_PST3_TAP","DSNAP_BU_PST4_TAP","DSNAP_BU_PST5_TAP","DSNAP_DFS_N_ARTW","DSNAP_DFS_N_AVMN","DSNAP_DFS_N_BYCR","DSNAP_DFS_N_BYSW","DSNAP_DFS_N_CNYS","DSNAP_DFS_N_DTMN","DSNAP_DFS_N_LDTW","DSNAP_DFS_N_LTMS","DSNAP_DFS_N_MNYS","DSNAP_DFS_N_MSUT","DSNAP_DFS_N_TWUL","DSNAP_DFS_V_BABE_5M","DSNAP_DFS_V_BAML","DSNAP_DFS_V_BAML_5M","DSNAP_DFS_V_DDMB","DSNAP_DFS_V_DDMS","DSNAP_DFS_V_DDSM","DSNAP_DFS_V_EPTT","DSNAP_DFS_V_MLGT1","DSNAP_DFS_V_MLGT2","DSNAP_DFS_V_ROYP","DSNAP_INFO_NSW_INER","DSNAP_INFO_QLD_INER","DSNAP_INFO_SA_INER","DSNAP_INFO_TAS_INER","DSNAP_INFO_TNTH_INER","DSNAP_INFO_VIC_INER","DSNAP_LRHS_1","DSNAP_LRHS_2","DSNAP_MLGT_MLGT_CONT","DSNAP_MLGT_MLGT_HC","DSNAP_MLGT_MLGT_LB","DSNAP_MLNK_RAT_LIM","DSNAP_N::N_NIL_LTWG","DSNAP_N_MSL_BESS_CHG","DSNAP_Q>>MITUM","DSNAP_Q>WOCY_1","DSNAP_Q>WOGP","DSNAP_Q^^NIL_TR_CLHA","DSNAP_Q^^NIL_TR_TRBK","DSNAP_Q_BKSP838","DSNAP_Q_MSL_BESS_CHG","DSNAP_Q_TR_1500","DSNAP_S_MSL_BESS_CHG","DSNAP_T_TV_BL_DYN","DSNAP_T_VT_BL_DYN","DSNAP_VS_600_TEST","DSNAP_V^^_NIL_SWVIC1","DSNAP_V^^_NIL_SWVIC2","DSNAP_V^^_NIL_SWVIC3","DSNAP_V^^_NIL_SWVIC4","DSNAP_V_MSL_BESS_CHG","D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_NIL_SNOW_N+S_100","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_WF_TG_R1","D_V_HEYWOOD_OFGS_1","D_V_HEYWOOD_OFGS_2","D_V_HEYWOOD_OFGS_3","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6","I_6F_NS_150","I_6F_SN_150","N::N_NIL_63","N::Q_BWMP_KC","N::Q_BWMP_LDMU","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N::Q_NIL_KC","N::Q_NIL_LDMU","N::Q_NIL_LDTW","N::Q_NIL_TNT","N::V_NIL_BWSW","N::V_NIL_MSDD","N::V_NIL_UTMS","N:V_NIL_BWRG","N:V_NIL_BYYS","N>94T_945_94K","N>94T_947_72","N>94T_94K1_945","N>>BWMP_23_22","N>>BWMP_81_31","N>>BWMP_81_82","N>>BWMP_82_81","N>>CHTX_966_87","N>>NIL_01_62","N>>NIL_060","N>>NIL_060_051","N>>NIL_07","N>>NIL_1","N>>NIL_16_18","N>>NIL_16_39","N>>NIL_16_3W","N>>NIL_16_76","N>>NIL_16_8","N>>NIL_18_16","N>>NIL_18_4_N","N>>NIL_18_4_S","N>>NIL_18_5_N","N>>NIL_18_5_S","N>>NIL_18_61","N>>NIL_18_8","N>>NIL_1_3","N>>NIL_1_3_LSC1_ON","N>>NIL_1_6X","N>>NIL_1_6X_LSC1_ON","N>>NIL_1_7","N>>NIL_1_7_LSC1_ON","N>>NIL_23_22","N>>NIL_23_25","N>>NIL_3","N>>NIL_33_34","N>>NIL_39","N>>NIL_39_11","N>>NIL_39_17","N>>NIL_3G","N>>NIL_3L","N>>NIL_3L_18_N","N>>NIL_3L_3J_N","N>>NIL_3L_3P_N","N>>NIL_3L_3W","N>>NIL_3L_5_N","N>>NIL_3_7","N>>NIL_3_7_LSC1_ON","N>>NIL_3_7_LSC2_ON","N>>NIL_4","N>>NIL_4_18_S","N>>NIL_4_5_N","N>>NIL_4_5_S","N>>NIL_4_61_N","N>>NIL_4_61_S","N>>NIL_4_6_S","N>>NIL_5_18_N","N>>NIL_5_18_S","N>>NIL_5_3J_N","N>>NIL_5_3L_N","N>>NIL_5_3P_N","N>>NIL_5_3W","N>>NIL_5_4_S","N>>NIL_5_61_N","N>>NIL_5_61_S","N>>NIL_5_6_S","N>>NIL_61_18","N>>NIL_61_3L","N>>NIL_61_3W","N>>NIL_61_4","N>>NIL_61_5","N>>NIL_64_65","N>>NIL_6M_66","N>>NIL_6X","N>>NIL_6X_1","N>>NIL_6X_3","N>>NIL_6X_9","N>>NIL_70_71","N>>NIL_76_77","N>>NIL_77_76","N>>NIL_7_1","N>>NIL_7_1_LSC1_ON","N>>NIL_7_3","N>>NIL_7_3_LSC1_ON","N>>NIL_7_3_LSC2_ON","N>>NIL_81","N>>NIL_81_31","N>>NIL_81_82_CLOSE","N>>NIL_81_82_OPEN","N>>NIL_82","N>>NIL_82_81_CLOSE","N>>NIL_82_81_OPEN","N>>NIL_83_84_CLOSE","N>>NIL_83_84_OPEN","N>>NIL_84_83_CLOSE","N>>NIL_84_83_OPEN","N>>NIL_84_88_S","N>>NIL_85_86_S","N>>NIL_86_85_N","N>>NIL_86_85_S","N>>NIL_86_8U_S","N>>NIL_86_N","N>>NIL_86_NIL_S","N>>NIL_88_84_N","N>>NIL_88_84_S","N>>NIL_8E_8C_S","N>>NIL_8U_86_S","N>>NIL_8_16","N>>NIL_8_18","N>>NIL_8_3W","N>>NIL_964_84_S","N>>NIL_964_88_S","N>>NIL_966/1_87_S","N>>NIL_967_89_S","N>>NIL_990","N>>NIL_991","N>>NIL_994","N>>NIL_996_62","N>>NIL_9W2_9W8","N>>NIL_9_18_N","N>>NIL_9_18_S","N>>NIL_9_6","N>>NIL_DPTX_HV","N>>NIL_DPTX_LV","N>>NIL_X3_060","N>>V_NIL_65","N>>V_NIL_65_66","N>>V_NIL_65_LTWG","N>>V_NIL_66","N>>V_NIL_66_65","N>>V_NIL_66_LTWG","N>N-NIL_TE_LOAD","N>NIL_051","N>NIL_64_S","N>NIL_6M_N","N>NIL_75_WOTX_72","N>NIL_8J_8C","N>NIL_901","N>NIL_945_947","N>NIL_947_94T","N>NIL_94B","N>NIL_94K_1","N>NIL_94M","N>NIL_94T","N>NIL_94T_72","N>NIL_94T_75","N>NIL_94T_7J","N>NIL_94T_947","N>NIL_967_89","N>NIL_969","N>NIL_96C_87","N>NIL_973","N>NIL_977_976","N>NIL_983_987","N>NIL_997/1_3G","N>NIL_997/2_3G","N>NIL_997/2_99A","N>NIL_997_99A","N>NIL_998","N>NIL_998_18","N>NIL_999","N>NIL_999_9GL","N>NIL_999_S","N>NIL_99F","N>NIL_99U","N>NIL_9GL","N>NIL_9GM","N>NIL_9J5/1","N>NIL_9J5/2","N>NIL_9J6","N>NIL_9ML","N>NIL_9R1","N>NIL_9R4","N>NIL_9R4_62","N>NIL_9R4_99A","N>NIL_9R4_9R3","N>NIL_9R5","N>NIL_9R5_9R6","N>NIL_9R6","N>NIL_9R6_991","N>NIL_9R6_9R5","N>NIL_9U3","N>NIL_9U9_9U8","N>NIL_BHTX_HV","N>NIL_BHTX_LV","N>NIL_CLDP","N>NIL_LSDU","N>NIL_MBDU","N>NIL_PKTX_LV","N>NIL_X2","N>NIL_YSTX_LV","N>Q-NIL_757_758","NQ_950_TEST","NRM_NSW1_QLD1","NRM_NSW1_VIC1","NRM_QLD1_NSW1","NRM_SA1_VIC1","NRM_TAS1_VIC1","NRM_VIC1_NSW1","NRM_VIC1_SA1","NRM_VIC1_TAS1","N^^N_NIL_1","N^^N_NIL_WGLT","N^^N_NIL_X5_BEKG","N^^N_NIL_X5_BESH","N^^Q_NIL_CPP_3","N^^Q_NIL_CPP_4","N^^Q_NIL_KPP_1","N^^Q_NIL_MAXGEN","N^^Q_NIL_MPP_1","N^^Q_NIL_MPP_2","N^^Q_NIL_TNPS1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_NIL_TE_A","N_NIL_TE_B","N_WDR_NO_SCADA","Q:NIL_CS","Q>>NIL_MRTX4_MRTX5","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q>NIL_BCCP_CLWU","Q>NIL_BCCP_LCCP","Q>NIL_BCRG_BCCP","Q>NIL_BCRG_CLWU","Q>NIL_BCST_BCST","Q>NIL_BI_FB","Q>NIL_CLBTX_CLBTX","Q>NIL_CLWU_BCRG","Q>NIL_CLWU_LCCP","Q>NIL_CPWU_CLWU","Q>NIL_DRLCLB_NIL","Q>NIL_LCCP_BCCP","Q>NIL_LCCP_CLWU","Q>NIL_MRTA_C","Q>NIL_MUTE_757","Q>NIL_MUTE_758","Q>NIL_MUTX_MUTX","Q>NIL_PWSP_WOSP","Q>NIL_RGLC_BCCP","Q>NIL_RGLC_CLWU","Q>NIL_TV66","Q>NIL_WOPW_WOSP","Q>NIL_WOSP_PWSP","Q>NIL_WOSP_WOPW","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","QN_1400_TEST","Q^CN_FDR-060","Q^CN_GT-090","Q^CS_-080","Q^NIL_CN_FDR","Q^NIL_CN_GT","Q^NIL_CS","Q^NIL_FNQ_8905","Q^NIL_GC","Q^^NIL_TR_CLHA","Q^^NIL_TR_TRBK","Q^^N_NIL_SRAR","Q^^TR_CLHA_-050","Q^^TR_CLHA_-350","Q^^TR_TRBK_-050","Q^^TR_TRBK_-100","Q_CS_2000","Q_KEP-HYB_50MW","Q_STR_NIL_KEP","S::V_NIL_TBSE_1","S:VS_800","S:VS_900_HY_TEST","S:V_650","S:V_700_HY_TEST","S>>HUWT_BRTX_MNWT","S>>HUWT_BWPA_BRTW","S>>HUWT_BWPA_TWPA","S>>HUWT_RBTU_WEWT","S>>NIL_BGBW_BRTW","S>>NIL_BRTW_WEMW4","S>>NIL_BRTW_WTTP","S>>NIL_BRTX_WEMW4","S>>NIL_BRTX_WTTP","S>>NIL_BWMP_BRTW","S>>NIL_BWMP_RBTU","S>>NIL_BWMP_TPRS","S>>NIL_BWMP_TWPA","S>>NIL_BWMP_WEMW4","S>>NIL_BWMP_WTTP","S>>NIL_CNRB_WEMW4","S>>NIL_HUBG-T_WEWT","S>>NIL_LKDV_WEWT","S>>NIL_MKRB_WEMW4","S>>NIL_RBNW1_MWP1NWB","S>>NIL_RBNW1_RBMWP3","S>>NIL_RBTU_BRTW","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_TWPA","S>>NIL_RBTU_WEWT","S>>NIL_RBTU_WTTP","S>>NIL_RBTX1_WTWE","S>>NIL_RBTX_RBTX_1","S>>NIL_RBTX_RBTX_2","S>>NIL_SETB_SETB_1","S>>NIL_TBSE_PWSE_1","S>>NIL_TBSE_TBSE_1","S>>NIL_TBTU_TBMO_1","S>>NIL_TBTU_TBTU_1","S>>NIL_TBTX4_TBMO_1","S>>NIL_TPWTX_TPDR","S>>NIL_TUTB_MOTB_1","S>>NIL_TUTB_TUTB_1","S>>NIL_TWPA_BWMP","S>>NIL_TWPA_TPRS","S>>NIL_TWPA_WEMW4","S>>V_NIL_DVBG_STBG","S>>V_NIL_NIL_HUWT","S>>V_NIL_NIL_MNWT","S>>V_NIL_NIL_MW1NWB","S>>V_NIL_NIL_RBMW3","S>>V_NIL_NIL_RBNW1","S>>V_NIL_RBTX_WEMW4","S>>V_NIL_WTTP_WEMW4","S>HUWT_BGTX_RHBR-T","S>HUWT_BWPA_RHBR-T","S>HUWT_NIL_STBG-T","S>NIL_ACPA_MAMO","S>NIL_BRTW_MNWT","S>NIL_BWMP_CNRB","S>NIL_BWMP_HUWT","S>NIL_BWMP_RHBR-T","S>NIL_DVBG_BRTW","S>NIL_DVTX_DVTX","S>NIL_HUWT_STBG","S>NIL_LKDV_CNRB","S>NIL_MHNW1_MHNW2","S>NIL_NIL_DLAW","S>NIL_NIL_MHNW2","S>NIL_NIL_MYSG-T","S>NIL_NIL_NWMH2","S>NIL_NIL_SETX12","S>NIL_NIL_SGBN","S>NIL_NIL_SGMYSE-T2","S>NIL_NWMH1_NWMH2","S>NIL_NWRB1_MWP3RB","S>NIL_NWRB2_NWRB1","S>NIL_RBMWP3_RBNW1","S>NIL_SGBN_SGSE-T","S>NIL_SGBN_SGSE-T2","S>NIL_TINO3_TINO4","S>NIL_WEMW4_WTTP","S>V_NIL_SEHY","S>V_NIL_SETX_SETX","S>V_NIL_SETX_SETX1","SVML^NIL_MH-CAP_ON","SVML_233","SVML_RAT_LIM_DYN","SVML_ZERO","SV_HEY_600_TEST","S^NIL_SA_NORTH","S_NIL_STRENGTH_1","S_V_HEYWOOD_OFGS","S_V_NIL_ROCOF","T::T_NIL_1","T::T_NIL_3","T>>T_NIL_BL_EXP_3F","T>>T_NIL_BL_EXP_3G","T>>T_NIL_BL_EXP_3H","T>>T_NIL_BL_EXP_4E","T>>T_NIL_BL_EXP_4F","T>>T_NIL_BL_EXP_5F","T>>T_NIL_BL_EXP_5G","T>>T_NIL_BL_EXP_5H","T>>T_NIL_BL_EXP_6E","T>>T_NIL_BL_EXP_6F","T>>T_NIL_BL_EXP_7C","T>T_NIL_110_4","T>T_NIL_110_5","T>T_NIL_BL_110_2","T>T_NIL_BL_110_3","T>T_NIL_BL_110_4","T>T_NIL_BL_110_5","T>T_NIL_BL_110_8_1","T>T_NIL_BL_110_9","T>T_NIL_BL_220_6B","T>T_NIL_BL_220_6C","T>T_NIL_BL_220_6D","T>T_NIL_BL_3A","T>T_NIL_BL_3B","T>T_NIL_BL_3C","T>T_NIL_BL_3D","T>T_NIL_BL_3E","T>T_NIL_BL_4A","T>T_NIL_BL_4B","T>T_NIL_BL_4C","T>T_NIL_BL_4D","T>T_NIL_BL_5A","T>T_NIL_BL_5B","T>T_NIL_BL_5C","T>T_NIL_BL_5D","T>T_NIL_BL_5E","T>T_NIL_BL_6A","T>T_NIL_BL_6B","T>T_NIL_BL_6C","T>T_NIL_BL_6D","T>T_NIL_BL_IMP_2B","T>T_NIL_BL_IMP_3F","T>T_NIL_BL_IMP_3FF","T>T_NIL_BL_IMP_3G","T>T_NIL_BL_IMP_3H","T>T_NIL_BL_IMP_4E","T>T_NIL_BL_IMP_4EE","T>T_NIL_BL_IMP_4F","T>T_NIL_BL_IMP_5F","T>T_NIL_BL_IMP_5FF","T>T_NIL_BL_IMP_5G","T>T_NIL_BL_IMP_5H","T>T_NIL_BL_IMP_6E","T>T_NIL_BL_IMP_6EE","T>T_NIL_BL_IMP_6F","T>T_NIL_BL_IMP_7C","T>T_NIL_BL_IMP_7CC","T>T_NIL_BL_IMP_8B","T>T_NIL_BL_IMP_8C","T>T_NIL_NCSPS5_3F","T>T_NIL_NCSPS5_3FF","T>T_NIL_NCSPS5_3G","T>T_NIL_NCSPS5_3H","T>T_NIL_NCSPS5_7C","T>T_NIL_TOV_5F","T>T_NIL_TOV_5FF","TVBL_NIL_CONT_459","TVBL_NIL_DYN","T^T_NIL_BL_1","T^T_NIL_BL_2","T^T_NIL_BL_4","T^T_NIL_BL_5","T^T_NIL_BL_6","T^T_NIL_BL_7","T^V_NIL_10","T^V_NIL_11","T^V_NIL_8","T^V_NIL_9","T^V_NIL_BL_6","T_ROCOF_1","T_ROCOF_2","T_ROCOF_3_1","T_ROCOF_3_2","T_ROCOF_3_3","T_V_NIL_FCSPS","V::N_NIL_O1","V::N_NIL_O2","V::N_NIL_V1","V::N_NIL_V2","V::S_NIL_MAXG_1","V::S_NIL_TBSE_1","V::V_1900","V:SS_920","V:SS_970_HY_TEST","V:S_700","V:S_750_HY_TEST","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DBL_MSDD_MSDD","V>>DBL_MSDD_MSDD_SIP","V>>DBT_DDTX1_DDTX","V>>DBT_DDTX2_DDTX","V>>DBT_DDTX3_DDTX","V>>DDTX1_3_DDTX2_NIL","V>>DDTX2_3_DDTX1_NIL","V>>DDTX3_DDT1_DD2_LH","V>>DDTX3_DDT2_DD1_LH","V>>DDTX3_DDTX1_DDTX2","V>>DDTX3_DDTX2_DDTX1","V>>DDTX_DDTX1_NIL_LH","V>>DDTX_DDTX2_NIL_LH","V>>NIL_ARTSTL_ARCW","V>>NIL_ARWB_KGBE","V>>NIL_ARWB_RCWEKG","V>>NIL_BABE_HOMRKM","V>>NIL_BABE_KMRC","V>>NIL_BABE_KMRC_1","V>>NIL_BABE_RCWEKO","V>>NIL_BABE_SHBE","V>>NIL_BABE_SHBE_5M","V>>NIL_BANBGR_ARCW","V>>NIL_BEBA_ARWBBA","V>>NIL_BEKG_HOMRKM","V>>NIL_BGRART_ARCW","V>>NIL_CWAR_KGBE","V>>NIL_DDSM_DDSM","V>>NIL_DDSM_DDSM_SIP","V>>NIL_DDTX1_NIL","V>>NIL_DDTX2_NIL","V>>NIL_DDTX3_NIL","V>>NIL_ELML_BAML2","V>>NIL_EPTT_DDSM_SIP","V>>NIL_HYSE_HYSE","V>>NIL_KGWE_HOMRKM","V>>NIL_MBDD_MBDD","V>>NIL_MLGT_MLGT","V>>NIL_MLSY_MLSY","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD1_MSDD2_S","V>>NIL_MSDD2_MSDD1","V>>NIL_MSDD2_MSDD1_S","V>>NIL_RCWE_BUBD","V>>NIL_RCWE_HOBUCW","V>>NIL_RCWE_HOMRKM","V>>NIL_SMDD_SMDD","V>>NIL_SMTX_SMTX_R2","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>NIL_WEKG_HOBUCW","V>>NIL_WEKG_HOMRKM","V>>NIL_WERC_HOMRKM","V>>NSWRB_BEKG_X3","V>>NSWRB_BEKG_X5","V>>NSWRB_KGWE_X3","V>>NSWRB_KGWE_X5","V>>NSWRB_WERC_X3","V>>NSWRB_WERC_X5","V>>N_NIL_65","V>>N_NIL_65_051","V>>N_NIL_65_66","V>>N_NIL_66","V>>N_NIL_66_051","V>>N_NIL_66_65","V>>SMF1_SMF2_NIL_R2","V>>SMF1_SMF2_NIL_R5","V>>SMF2_SMF1_NIL_R2","V>>SMF2_SMF1_NIL_R5","V>>SMF_SMF_ROTX1_R2","V>>SMF_SMF_ROTX1_R5","V>>S_NIL_DVBG_DVBR","V>>X9_WBBA_RCX1","V>NIL_GNTX_GNTX","V>NIL_GNTX_GNTX_TEMP","V>NIL_TGTX_NIL","V>NIL_TGTX_TGTX_2","V>NIL_TGTX_TGTX_20S","V>NIL_WBBA_CWBUHO","V>NIL_WBBA_HOMRKM","V>NIL_WBBA_KMRC","V>NIL_WBBA_KMRC_1","V>NIL_WETX_NIL","V>NIL_YPRO7_YPHW1","V>NIL_YPRO7_YPRO8","V>S_NIL_SETX_SETX","VSML_220","VSML_RAT_LIM_DYN","VSML_ZERO","VS_HEY_600_TEST","VS_HEY_650_TEST","VTBL_NIL","VTBL_NIL_CONT_441","V^^N_NIL_1","V^^S_NIL_MAXG_1","V^^S_NIL_TBSE_1","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V^^V_NIL_KGTS_2","V_DUNDWF1_2_3_168","V_GANWR_SF_BAT_50","V_NWVIC_GFT1_750","V_SH_DD_MAC_FLT_965","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF","V_T_NIL_FCSPS","V_WDR_NO_SCADA"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run.","examples":["0"],"is_boolean":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:12:38"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregation of the constraints LHS term solution values in MW","examples":["-2.11088","0.46306","0","1214"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of constraint (>0 if binding) in $/MW","examples":["-0.02932","0.01","0","4.95"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Right Hand Side value in the capacity evaluation in MW","examples":["-3.21299","18.71005","0","34731"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of Violation (>0 if violating) in MW","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":14,"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":404987903,"decompressed_size_all_time":1177896503850},"visibility":"Public","trigger":"Publishes few times per day"},"PD7DAY_INTERCONNECTORSOLUTION":{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"INTERCONNECTORSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#13"],"comment":"PD7DAY intereconnector solution","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","INTERVENTION","RUN_DATETIME"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run.","examples":["0"],"is_boolean":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EXPORTCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["I_6F_NS_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^^N_NIL_WGLT","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_WEWT","S>NIL_MHNW1_MHNW2","T_V_NIL_FCSPS","V::N_HWRO3_O2","V::N_HWRO3_V2","V::N_HWSM_S1","V::N_HWSM_V2","V::N_MLTX_O2","V::N_MLTX_V2","V::N_NIL_O2","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","V>>SMF1_SMF2_NIL_R5","VSML_ZERO","VS_HEY_600_TEST","V^^N_CNCW_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-0.00001","0.50135","0","950"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-0.00001","44.98731","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + Frequency Controlled Ancillary Services.","examples":["-21.05416","0.00001","0","-2478"],"is_float":true},"IMPORTCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R60","I_6F_NS_150","I_6F_SN_150","N>>NIL_060_051","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_966/1_87_S","N^^N_NIL_WGLT","N^^V_CNCW_1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_ARWBBA","N_NIL_TE_B","Q>NIL_757_758_ECS","S:VS_800","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","SVML_ZERO","S_V_HEYWOOD_OFGS","S_V_NIL_ROCOF","T::T_NIL_3","T_ROCOF_3_3","V::N_HWRO3_V2","V::N_HWSM_S1","V::N_HWSM_V2","V::N_MLTX_V2","V::N_NIL_O2","V::N_NIL_V2","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DDTX3_DDTX2_DDTX1","V>>NIL_ELML_BAML2","V>>NIL_MLGT_MLGT","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>SMF1_SMF2_NIL_R5","V>>X9_WBBA_RCX1","VTBL_NIL_CONT_441","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V^^V_NIL_KGTS_2"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-21.05416","0.00001","0","-1247"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:12:38"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.32","0","-6","-26"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.33","0","23","8352000"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor at the cleared flow","examples":["0.42673","1.59769"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal cost of Interconnector standing data limits (if binding)","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"SCADA MW Flow measured at Run start. For periods subsequent to the first period of a PD7DAY run, this value represents the cleared target for the previous period of that PD7DAY run.","examples":["-2.991","0.50134","0","391"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector loading level (MW)","examples":["-2.991","0.50134","0","391"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector Losses at cleared flow","examples":["-0.0055","0.01123","0","132.15037"],"is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation of Interconnector standing data limits","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_INTERCONNECTORSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":6199253,"decompressed_size_all_time":18261647300},"visibility":"Public","trigger":"Publishes few times per day"},"PD7DAY_MARKET_SUMMARY":{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"MARKET_SUMMARY","VERSION":1},{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"MARKET_SUMMARY","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#19"],"comment":"PD7DAY market summary showing calculated gas fuel forecasts","primary_keys":["INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"GPG_FUEL_FORECAST_TJ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The total gas consumption in TJ","examples":["7.72","30","226.93","170"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_MARKET_SUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":5272,"decompressed_size_all_time":16444950},"visibility":"Public","trigger":"Publishes few times per day"},"PD7DAY_PRICESOLUTION":{"package":"PD7DAY","pdr_config":{"mappings":[{"REPORT_NAME":"PD7DAY","REPORT_SUB_TYPE":"PRICESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec77.htm#25"],"comment":"PD7DAY price solution","primary_keys":["INTERVAL_DATETIME","INTERVENTION","REGIONID","RUN_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"Flag to indicate if this Predispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run.","examples":["0"],"is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 07:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BDU_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy Storage for BDU at the start of the interval(MWh) - Region Aggregated","is_float":true},"DECGEN_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy storage for Daily Energy Constrained Scheduled Generating Units at the start of the interval(MWh) - Region Aggregated","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 07:12:38"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Lower 1Sec Price - RegionSolution element L1Price attribute","examples":["0.01","0"],"is_float":true},"LOWER5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower5Min)","examples":["0.01","0","1","0.8"],"is_float":true},"LOWER6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower6Sec)","examples":["0.01","0","1","10"],"is_float":true},"LOWER60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Lower60Sec)","examples":["0.01","1","6.99","5"],"is_float":true},"LOWERREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (LowerReg)","examples":["0.03","0","2","50"],"is_float":true},"RAISE1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Raise 1Sec Price - R1Price attribute after capping/flooring","examples":["0.01","0","1","5"],"is_float":true},"RAISE5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise5Min)","examples":["0.01","0","0.38"],"is_float":true},"RAISE6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise6Sec)","examples":["0.01","24","36.97531","25"],"is_float":true},"RAISE60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Raise60Sec)","examples":["0.01","0.38"],"is_float":true},"RAISEREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (RaiseReg)","examples":["0.01","3","62.4","35"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reference Price (Energy)","examples":["-0.92081","0.00003","0","1001"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD7DAY_PRICESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1878922,"decompressed_size_all_time":6265653470},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Publishes few times per day"},"PDPASA_CASESOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#1"],"comment":"The top-level table identifying a PDPASA case, reporting options applied in the case and summary results","description":"PDPASA_CASESOLUTION is public data.\n\nSource\n\nPDPASA_CASESOLUTION is updated each PDPASA run (i.e. half-hourly).\n\nVolume\n\nRows per day: 48\n\nMb per month: \\<1","primary_keys":["RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Case identifier by the time the case was run","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CAPACITYOBJFUNCTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Objective Function from the Capacity Adequacy run","examples":["226422.693","958319.955"],"is_float":true},"CAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the Probability of Exceedance (POE) demand forecast used for capacity adequacy (LRC) assessment. 0 if no assessment, 1 for 10% POE, 2 for 50% POE, 3 for 90% POE.","examples":["0"],"is_float":true},"INTERCONNECTORFLOWPENALTY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The penalty for non-zero interconnector flow","examples":["4.64"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was created or modified","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in LOR run (either PASA or MARKET)","examples":["Market"]},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LOR) flag for the case indicates the most severe condition in the case (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)","examples":["0","1","2"],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"LORDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for LOR assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["50"],"is_float":true},"LORUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["50"],"is_integer":true,"num_int_bits":16},"MAXSPARECAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the Probability of Exceedance (POE) demand forecast used for assessment of Maximum Spare Capacity. 0 if no assessment, 1 for 10% POE, 2 for 50% POE, 3 for 90% POE","examples":["0"],"is_float":true},"MAXSURPLUSRESERVEOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the Probability of Exceedance (POE) demand forecast used for assessment of Maximum surplus Reserve. 0 if no assessment, 1 for 10% POE, 2 for 50% POE, 3 for 90% POE","examples":["0"],"is_float":true},"OUTAGELRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Outage LRC run (either PASA or MARKET)","examples":["Market"]},"OUTAGELRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for outage LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["10"],"is_float":true},"OUTAGELRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"num_int_bits":16},"PASAVERSION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case","examples":["7.4.4.0"]},"RELIABILITYLRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Reliability LRC run (either PASA or MARKET)","examples":["PASA"]},"RELIABILITYLRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for Reliability LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["0"],"is_float":true},"RELIABILITYLRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"num_int_bits":16},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Low Reserve Condition (LRC) flag for the case (1 - LRC in the case, 0 - No LRCs in the case) for capacity run","examples":["0","1"],"is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":22441,"decompressed_size_all_time":30732930},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"},"PDPASA_CONSTRAINTSOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#10"],"comment":"PDPASA_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["#SSE_PPCCGT_20","$CPP_4","C_V_GPWFWST_462","I_6F_NS_150","I_6F_SN_150","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>94T_947_72","N>>NIL_39","N>>NIL_4","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_996_62","N>N-NIL_JUTX_LV","N>NIL_901","N>NIL_94K_1","N>NIL_94T","N>NIL_94T_72","N>NIL_969","N>NIL_9R6_991","N>NIL_LSDU","N>NIL_PKTX_LV","N^^N_NIL_1","N^^N_NIL_WGLT","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N_BERYLSF1_ZERO","N_NIL_TE_B","Q>NIL_757_758_ECS","Q>NIL_BCCP_LCCP","Q>NIL_CLWU_LCCP","Q>NIL_DRLCLB_NIL","Q>NIL_MRTA_C","Q>NIL_RGLC_BCCP","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","Q^^N_NIL_SRAR","Q_CS_2000","S:V_700_HY_TEST","S>>NIL_BWMP_WTTP","S>>NIL_RBTU_RBTU","S>>NIL_TWPA_TPRS","S>HUWT_BWPA_RHBR-T","S>V_NIL_SETX_SETX1","SVML_ZERO","S^CMWF_39","S^NIL_SA_NORTH","S^SNWWF_60","S_V_HEYWOOD_OFGS","T>T_NIL_BL_IMP_7CC","T^V_NIL_9","T^V_NIL_BL_6","T_MRWF_GCS","T_ROCOF_3_3","V::N_NIL_V2","V::V_1900","V>>BELML_BAML1_BAML2","V>>NIL_DDSM_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD2_MSDD1","V>>N_NIL_65_66","V>>SMF_SMF_ROTX1_R5","VSML_ZERO","VS_HEY_600_TEST","VTBL_NIL_CONT_441","V^^N_NIL_1","V_BURC_BANN1_SC_DYN","V_BURC_KARSF1_SC_DYN","V_BURC_WEMEN_SC_DYN","V_BURC_YATSF1_SC_DYN","V_DUNDWF1_2_3_168","V_NWVIC_GFT1_750","V_SH_DD_MAC_FLT_965","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are OUTAGE_LRC and LOR. Note that the PDPASA OUTAGE_LRC Run Type is discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":["LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["1"],"is_float":true},"CAPACITYRHS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The RHS value in the capacity evaluation.","examples":["-77.07","76.63","0","5051"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for generic constraint; 0 if not violating","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":2},"last_month":{"year":2026,"month":9},"compressed_size_per_month":26061507,"decompressed_size_all_time":20232417060},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"},"PDPASA_DUIDAVAILABILITY":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"DUIDAVAILABILITY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#16"],"comment":"This report delivers available capacity, PASA availability and given recall period for all scheduled resources. Note that for an MNSP, DUID = LINKID in the MNSP_INTERCONNECTOR table.","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM Dispatchable Unit Identifier","examples":["ADPPV1","AGLHAL","AGLSOM","BOWWPV1","BRAEMAR1","BRAEMAR2","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","PUMP2","QBYNB1","QPS1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","TORRB4","TREVALLN","TRGBESS1","WDBESS1","WDBESS2","WDGPH1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Half hour ended interval","examples":["2026/09/09 18:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"PDPASA run, identified by the first half hour ended interval of the run.","examples":["2026/09/09 18:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"GENERATION_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled generating unit, semi-scheduled generating unit, BDU (Gen side), WDR or MNSP.","examples":["0.033","0","1","255"],"is_float":true},"GENERATION_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.","examples":["0","8","255"],"is_integer":true,"num_int_bits":64},"GENERATION_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.","examples":["0","1","24000"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Report Creation Date Time.","examples":["2026/09/09 18:02:09"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled load or BDU(Load side).","examples":["0","89","386"],"is_float":true},"LOAD_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"PASA Availability for a scheduled load or BDU(Load side).","examples":["8","600"],"is_integer":true,"num_int_bits":64},"LOAD_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled load or BDU(Load side).","examples":["4","24000"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_DUIDAVAILABILITY%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":9,"first_month":{"year":2025,"month":7},"last_month":{"year":2026,"month":9},"compressed_size_per_month":173951093,"decompressed_size_all_time":141285891690},"visibility":"Public","trigger":"The start of PDPASA run or near to"},"PDPASA_FNM_CASESOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_CASESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#22"],"comment":"PDPASA_FNM_CASESOLUTION shows the case run details, including the available run types, LOR and Deficit condition for each case.","primary_keys":["RUN_DATETIME"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BASE_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"DEFICITCONDITION is only set if supply deficit exists in a Zone that does NOT contain the Regional Reference Node. DEFICITCONDITION indicates the most severe condition for the case:\nDEFICITCONDITION = 3 if deficit in BASE run, else = 2 if deficit in RELIABILITY run, else = 1 if deficit in WARNING run, else 0","is_integer":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"LORCONDITION is only set if supply deficit exists in a Zone that contains the Regional Reference Node. LORCONDITION indicates the most severe condition for the case:\nLORCONDITION = 3 if deficit in BASE run, else = 2 if deficit in RELIABILITY run, else = 1 if deficit in WARNING run, else 0","is_integer":true,"unsigned_int":true,"num_int_bits":8},"PASAVERSION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case"},"RELIABILITY_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"},"WARNING_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_CONSTRAINTSOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#28"],"comment":"PDPASA_FNM_CONSTRAINTSOLUTION shows manual or thermal constraint (created by PASA), including marginal value, violation degree, LHS and RHS.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(100)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier, either manual constraint (synonymous with GenConID) or thermal constraint created by PASA with format 'BASE_<BranchName>' or '<ContingencyID>_<BranchName>'","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint LHS (MW)","is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(20,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Marginal Value ($/MW)","is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint RHS (MW)","is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Violation Degree (MW)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_DUIDAVAILABILITY":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_DUIDAVAILABILITY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#34"],"comment":"PDPASA_FNM_DUIDAVAILABILITY shows Available Capacity, PASA Availability and Recall Period for all scheduled resources","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BID_OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time that the energy bid was received","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BID_TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Trading Date of the energy bid","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"GENERATION_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled generating unit, semi-scheduled generating unit, BDU (Gen side), WDR or MNSP (MW)","is_float":true},"GENERATION_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit (MW)","is_float":true},"GENERATION_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit (Hours)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled load or BDU (Load side) (MW)","is_float":true},"LOAD_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"PASA Availability for a scheduled load or BDU (Load side) (MW)","is_float":true},"LOAD_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled load or BDU (Load side) (Hours)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_INTERCONNECTORSOLN":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_INTERCONNECTORSOLN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#40"],"comment":"PDPASA_FNM_INTERCONNECTORSOLN shows cleared Interconnector flow for the interval.","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)"},"CLEAREDFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector flow (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_INTERZONALSOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_INTERZONALSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#46"],"comment":"PDPASA_FNM_INTERZONALSOLUTION shows cleared inter zonal flow for the interval and run type.","primary_keys":["INTERVAL_DATETIME","INTERZONALCONNECTORID","RUN_DATETIME","RUNTYPE"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERZONALCONNECTORID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":true,"comment":"InterzonalConnector Identifier"},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)"},"CLEAREDFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interzonal flow (MW)","is_float":true},"FROMZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"FromZoneID of the InterZonalConnectorID"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"ToZoneID of the InterZonalConnectorID"}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_REGIONSOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_REGIONSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#52"],"comment":"PDPASA_FNM_REGIONSOLUTION shows region demand, cleared values of resources, spare capacity, losses for each run type and intervals.","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNTYPE"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)"},"BDU_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (positive) or Consumption (negative) from bidirectional units (MW)","is_float":true},"CLEAREDDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Demand (MW)","is_float":true},"CLEAREDLOSSES":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Grid Losses (MW)","is_float":true},"CLEAREDNETINTERCHANGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Net Export (positive) or Net Import (negative) (MW)","is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (MW)","is_float":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain its Regional Reference Node\nDEFICITCONDITION = 3 if deficit in BASE run\nDEFICITCONDITION = 2 if deficit in RELIABILITY run\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"num_int_bits":8},"DEMAND_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to most probable Demand Forecast (MW)","is_float":true},"ENERGYCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from energy-constrained resources - that is, from bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"ENERGYUNCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from non energy-constrained resources - that is, excluding bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"INITIALDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Most probable Demand Forecast adjusted by Demand Uncertainty Margin (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists in the Zone for this Region that contains its Regional Reference Node\nLORCONDITION = 3 if deficit in BASE run\nLORCONDITION = 2 if deficit in RELIABILITY run\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"SCHED_GEN_AUX_LOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Auxiliary Load adjustment to uncertainty-adjusted Bid MaxAvail of all scheduled generating units (MW)","is_float":true},"SCHED_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to Scheduled Generation Bid Max Avail (MW)","is_float":true},"SPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Spare Generation Capacity = max(0, Available Generation minus [Cleared Generation minus Cleared Net Interchange]) (MW)","is_float":true},"SS_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled solar generating units (MW)","is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled wind generating units (MW)","is_float":true},"SUPPLYDEFICIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit (MW) across at all loads in the Region = Max(0, Initial Demand minus Cleared Demand) where Cleared Demand = (Cleared Generation minus Cleared Losses minus Cleared Net Interchange).\nSupply Deficit = Supply Deficit_RRN + Supply Deficit_NonRRN","is_float":true},"SUPPLYDEFICIT_NONRRN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit across all loads in the Zone(s) that do not contain the Regional Reference Node (MW)","is_float":true},"SUPPLYDEFICIT_RRN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit across all loads in the Zone that contains the Regional Reference Node (MW)","is_float":true},"VRE_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to most probable VRE Forecast (MW)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_REGIONSUMMARY":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_REGIONSUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#58"],"comment":"PDPASA_FNM_REGIONSUMMARY shows the summary of PDPASA outcome for each region.","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain its Regional Reference Node DEFICITCONDITION indicates the most severe condition:\nDEFICITCONDITION = 3 if deficit in BASE run; else\nDEFICITCONDITION = 2 if deficit in RELIABILITY run; else\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"num_int_bits":8},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast (MW)","is_float":true},"DEMAND50_UNSCHED_GEN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast plus Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists in the Zone for this Region that contains its Regional Reference Node\nLORCONDITION indicates the most severe condition:\nLORCONDITION = 3 if deficit in BASE run; else\nLORCONDITION = 2 if deficit in RELIABILITY run; else\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"SCHED_LOAD_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled loads (MW)","is_float":true},"SCHED_SS_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled generating units, scheduled bidirectional units (Gen side) and semi-scheduled generating units, with latter capped at UIGF (MW)","is_float":true},"SCHED_SS_GEN_PASAAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid PASAAvailability of all scheduled generating units and scheduled bidirectional units (Gen side) with a Bid Recall Period less than (Interval_DateTime minus Run_DateTime) plus UIGF for all semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all solar semi-scheduled generating units (MW)","is_float":true},"SS_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all semi-scheduled generating units (MW)","is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all wind semi-scheduled generating units (MW)","is_float":true},"UNSCHED_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_ZONESOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_ZONESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#64"],"comment":"PDPASA_FNM_ZONESOLUTION shows zone demand, cleared values of resources, spare capacity, losses for each run type and intervals.","primary_keys":["INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","ZONEID"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)"},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Zone identifier"},"BDU_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (positive) or Consumption (negative) from bidirectional units (MW)","is_float":true},"CLEAREDDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Demand (MW)","is_float":true},"CLEAREDLOSSES":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Grid Losses (MW)","is_float":true},"CLEAREDNETINTERCHANGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Net Export (positive) or Net Import (negative) (MW)","is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (MW)","is_float":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit exists and this Zone does not contain the Regional Reference Node\nDEFICITCONDITION = 3 if deficit in BASE run\nDEFICITCONDITION = 2 if deficit in RELIABILITY run\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"num_int_bits":8},"DEMAND_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (increase) to most probable Demand Forecast (MW)","is_float":true},"ENERGYCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from energy-constrained resources - that is, from bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"ENERGYUNCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from non energy-constrained resources - that is, excluding bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"INITIALDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Most probable Demand Forecast adjusted by Demand Uncertainty Margin (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists and this Zone contains the Regional Reference Node\nLORCONDITION = 3 if deficit in BASE run\nLORCONDITION = 2 if deficit in RELIABILITY run\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier of the Region containing this Zone","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCHED_GEN_AUX_LOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Auxiliary Load adjustment to uncertainty-adjusted Bid MaxAvail of all scheduled generating units (MW)","is_float":true},"SCHED_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (decrease) to Scheduled Generation Bid Max Avail (MW)","is_float":true},"SPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Spare generation capacity = max(0, Available Generation minus [Cleared Generation minus Cleared Net Interchange]) (MW)","is_float":true},"SS_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled solar generating units (MW)","is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled wind generating units (MW)","is_float":true},"SUPPLYDEFICIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit at loads = Max(0, Initial Demand minus Cleared Demand) where Cleared Demand = (Cleared Generation minus Cleared Losses minus Cleared Net Interchange) (MW)","is_float":true},"VRE_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (decrease) to most probable VRE Forecast (MW)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_FNM_ZONESUMMARY":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"FNM_ZONESUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#70"],"comment":"PDPASA_FNM_ZONESUMMARY shows the summary of PDPASA outcome for each zone.","primary_keys":["INTERVAL_DATETIME","RUN_DATETIME","ZONEID"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Zone identifier"},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain the Regional Reference Node. DEFICITCONDITION indicates the most severe condition:\nDEFICITCONDITION = 3 if deficit in BASE run; else\nDEFICITCONDITION = 2 if deficit in RELIABILITY run; else\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"num_int_bits":8},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast (MW)","is_float":true},"DEMAND50_UNSCHED_GEN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast plus Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists and this Zone contains the Regional Reference Node\nLORCONDITION indicates the most severe condition:\nLORCONDITION = 3 if deficit in BASE run; else\nLORCONDITION = 2 if deficit in RELIABILITY run; else\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier of the Region containing this Zone","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCHED_LOAD_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled loads (MW)","is_float":true},"SCHED_SS_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled generating units, scheduled bidirectional units (Gen side) and semi-scheduled generating units, with latter capped at UIGF (MW)","is_float":true},"SCHED_SS_GEN_PASAAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid PASAAvailability of all scheduled generating units and scheduled bidirectional units (Gen side) with a Bid Recall Period less than (Interval_DateTime minus Run_DateTime) plus UIGF for all semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all solar semi-scheduled generating units (MW)","is_float":true},"SS_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all semi-scheduled generating units (MW)","is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all wind semi-scheduled generating units (MW)","is_float":true},"UNSCHED_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes"},"PDPASA_INTERCONNECTORSOLN":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#76"],"comment":"PDPASA_INTERCONNECTORSOLN shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are OUTAGE_LRC and LOR. Note that the PDPASA OUTAGE_LRC Run Type is discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":["LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"]},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-27.99","0.59","0","1752"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-24.13","45.76","0","-1379"],"is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["0"],"is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints","examples":["-14.95","0.59","0","-1379"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for interconnector capacity; 0 if not violating","examples":["0"],"is_float":true},"EXPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Export Limit","examples":["I_6F_NS_150","I_6F_SN_150","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_39","N>>NIL_4","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^^N_NIL_1","N^^N_NIL_WGLT","S>>NIL_BWMP_WTTP","S>>NIL_RBTU_RBTU","S>>NIL_TWPA_TPRS","T^V_NIL_9","T^V_NIL_BL_6","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","V>>N_NIL_65_66","V>>SMF_SMF_ROTX1_R5","VSML_ZERO","VS_HEY_600_TEST","V^^N_NIL_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"IMPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Import Limit","examples":["I_6F_NS_150","I_6F_SN_150","N:V_NIL_BYYS","N>>NIL_23_22","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N^^N_NIL_WGLT","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N_NIL_TE_B","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q^^N_NIL_SRAR","S:V_700_HY_TEST","SVML_ZERO","S_V_HEYWOOD_OFGS","T_ROCOF_3_3","V::N_NIL_V2","V::V_1900","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DDTX3_DDTX2_DDTX1","V>>NIL_DDSM_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_MLSY_MLSY","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD2_MSDD1","V>>SMF_SMF_ROTX1_R5","VTBL_NIL_CONT_441","V^^V_NIL_KGTS"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2021,"month":2},"last_month":{"year":2026,"month":9},"compressed_size_per_month":25655814,"decompressed_size_all_time":20398250750},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"},"PDPASA_REGIONSOLUTION":{"package":"PDPASA","pdr_config":{"mappings":[{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":6},{"REPORT_NAME":"PDPASA","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec67.htm#82"],"comment":"The PDPASA region solution data.Note that the OUTAGE_LRC Run Type is no longer reported from 31 July 2025.","description":"PDPASA_REGIONSOLUTION is public so is available to all participants.\n\nSource\n\nPDPASA_REGIONSOLUTION is updated each PDPASA run (i.e. half-hourly).\n\nVolume\n\nRows per day: 32000\n\nNotes\n\nLRC Determination\n\nSURPLUSRESERVE is the surplus reserve in a region based on meeting the\ndemand plus the reserve requirement in all regions simultaneously. Note\nthat any surplus above the network restrictions and system reserve\nrequirements is reported in the region it is generated, thus a surplus\nof zero can mean that a region is importing to meet a requirement or\nthat it has exported all surplus to meet an adjacent region’s\nrequirement.\n\n \n\nThe PASA processes also calculate a regionally optimised surplus called\nthe Maximum LRC Surplus (MAXSURPLUSRESERVE) being a figure on how much\ngeneration could be brought to this region subject to meeting\nrequirements in other regions.\n\n \n\nLOR Determination\n\nMAXSPARECAPACITY is a regionally optimised figure representing the\nsurplus generation able to be brought to a region subject to meeting the\ndemand in all other regions.\n\n \n\nParticipants are directed to the first half hour of the Predispatch PASA\n(PDPASA) reports as NEMMCO's latest reserve determination for a given\nhalf hour.","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run.","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of run. Values are OUTAGE_LRC and LOR. Note that the PDPASA OUTAGE_LRC Run Type is discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":["LOR"]},"AGGREGATECAPACITYAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities offered by all Scheduled units and Availability of all semi-scheduled units limited by MAXAVAIL in a given Region for a given PERIODID","examples":["1894.79","1960","16372.54","16216"],"is_float":true},"AGGREGATEPASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Sum of PASAAVAILABILITY for all scheduled generating units and scheduled bidirectional units (Gen side) with a Recall_Period <= 24 hours plus the sum of Unconstrained Intermittent Generation Forecasts (UIGF) for all semi-scheduled generating units. For the OUTAGE_LRC run, UIGF is the POE90 forecast. For the LOR Run, UIGF is the POE50 forecast. Note that the OUTAGE_LRC Run Type is discontinued from 31 July 2025. From March 2026, AGGREGATEPASAAVAILABILITY changes from that with Recall_Period <= 24 to that achievable by the relevant INTERVAL_DATETIME if recalled at the start of the run.","examples":["1965","18110"],"is_integer":true,"num_int_bits":64},"AGGREGATESCHEDULEDLOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities bid by of all Scheduled Loads in a given Region for a given PERIODID.","examples":["0","1"],"is_float":true},"CALCULATEDLOR1LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR1 used. Can be static value or calculated value if an interconnector is a credible contingency","examples":["387.849","585","1608.219168","1609"],"is_float":true},"CALCULATEDLOR2LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR2 used. Can be static value or calculated value if an interconnector is a credible contingency","examples":["279.47374","435","878.219168","879"],"is_float":true},"CAPACITYREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand + Reserve requirements (MW). This field is not populated after 30 July 2025.","is_float":true},"CONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Aggregate generation + WDR capacity from Energy Constrained plant subjected to restrictions due to network constraints.","examples":["0","5","2868"],"is_integer":true,"num_int_bits":64},"DEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"10% Probability of Exceedance demand forecast","examples":["936","9427"],"is_float":true},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast","examples":["882","9160"],"is_float":true},"DEMAND90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"90% Probability of Exceedance demand forecast","examples":["828","8892"],"is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["950","9281"],"is_float":true},"ENERGYREQDEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy (GWh) required for this energy block based on the 10% probability of exceedance demand. Listed in the first interval of the energy block","examples":["2.45","0","174.67"],"is_float":true},"ENERGYREQDEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of: (Region Demand50)/Period (sum by trading day, entered in first period of trading day, GWh).","examples":["2.35","0","169.85"],"is_float":true},"FUM":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecasting Uncertainty Measure. MW value of reserve calculated as defined in the Reserve Level Declaration Guidelines","examples":["47.549","80","762.896","160"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created.","examples":["2026/09/01 00:04:51"],"parse_csv_as_string":true,"is_s_datetime":true},"LCR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Largest Credible Risk. MW value for highest credible contingency","examples":["199.69807","435","878.219168","879"],"is_float":true},"LCR2":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Two Largest Credible Risks. MW value for highest two credible contingencies.","examples":["387.849","585","1608.219168","1609"],"is_float":true},"LOR_SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for semi-scheduled units for the region for the LOR run. Semi-scheduled generation is constrained by both System Normal and Outage constraints, and incorporate MAXAVAIL limits.","examples":["151.69","306","4094.21","3729"],"is_float":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lack of Reserve Condition (LOR) flag for this region and interval (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)","examples":["0"],"is_boolean":true,"unsigned_int":true,"num_int_bits":8},"LORNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the LOR assessment","examples":["-279.47","-297","-3138.66","-2982"],"is_float":true},"MAXSPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Spare Capacity (MW) evaluated for this region. Calculated for each region in turn. This value reflects Regional LOR reserve.","examples":["961.01","1106","7853.48","6521"],"is_float":true},"MAXSURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Surplus Reserve (MW) evaluated for this region from LRC runs. This field is no longer populated.","is_float":true},"MSRNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the MSR assessment. This field is no longer populated.","is_float":true},"NETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net export (MW) out of this region in the LOR evaluation. Export if > 0, Import if < 0. This value is the same as LORNETINTERCHANGEUNDERSCARCITY.","examples":["-279.47","-297","-3138.66","-2982"],"is_float":true},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Regional reserve condition from LRC run. This field is not populated after 30 July 2025.","is_integer":true,"num_int_bits":8},"RESERVEREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve Requirement (MW). This field is not populated after 30 July 2025.","is_float":true},"SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for semi-scheduled units for the region. For OUTAGE_LRC run and LOR run, semi-scheduled generation is constrained by both System Normal and Outage constraints. All run types (OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["151.69","306","4094.21","3729"],"is_float":true},"SS_SOLAR_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for solar for the region. For OUTAGE_LRC run and LOR run. solar generation is constrained by both System Normal and Outage constraints. All run types (OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["0.01","0","9","2057"],"is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for solar for the region. For OUTAGE_LRC run and LOR run, solar generation is constrained by both System Normal and Outage constraints. All run types (OUTAGE_LRC, LOR) incorporate MAXAVAIL limits. This value is the same as SS_SOLAR_CAPACITY.","examples":["0.01","0","9","2057"],"is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained Intermittent Generation Forecast for solar for the region. For OUTAGE_LRC run, this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run, this is the POE50 forecast.","examples":["0.01","0","3066","4524.41"],"is_float":true},"SS_WIND_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for wind for the region. For OUTAGE_LRC run and LOR run, wind generation is constrained by both System Normal and Outage constraints. All run types (OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["69.75","214","3547.11","3328"],"is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for wind for the region. For OUTAGE_LRC run and LOR run, wind generation is constrained by both System Normal and Outage constraints. All run types (OUTAGE_LRC, LOR) incorporate MAXAVAIL limits. This value is the same as SS_WIND_CAPACITY.","examples":["69.75","214","3547.11","3328"],"is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained Intermittent Generation Forecast for wind for the region. For OUTAGE_LRC run, this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run, this is the POE50 forecast.","examples":["151.69","306","4104.3","4025"],"is_float":true},"SURPLUSCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional surplus capacity (MW), +/- values indicate surplus/deficit capacity respectively. This value reflects Regional LOR reserve.","examples":["961.01","1106","7853.48","6521"],"is_float":true},"SURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional surplus reserve (MW). This value also reflects Regional LOR reserve. Note: For LOR runs, RESERVEREQ requirement input is not used.","examples":["961.01","1106","7853.48","6521"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["0","1","371"],"is_float":true},"UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["151.69","306","5669.67","5576"],"is_float":true},"UNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Aggregate generation + WDR capacity from Non-Energy Constrained plant subjected to restrictions due to network constraints.","examples":["1062","9275"],"is_integer":true,"num_int_bits":64},"WDR_AVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) availability in MW.","examples":["0","1"],"is_float":true},"WDR_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) capacity in MW.","examples":["0","1"],"is_float":true},"WDR_PASAAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) PASA availability in MW.","examples":["0","1"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PDPASA_REGIONSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":29275304,"decompressed_size_all_time":41136124650},"visibility":"Public","trigger":"After each PDASA run (half-hourly)"},"PD_FCAS_REQ_CONSTRAINT":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"FCAS_REQ_CONSTRAINT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#1"],"comment":"The constraint level FCAS cost / price details for constraint FCAS processor runs. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["BIDTYPE","CONSTRAINTID","INTERVAL_DATETIME","PREDISPATCHSEQNO","REGIONID","RUN_DATETIME","RUNNO"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"ConstraintID join to table GenConData","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The 30 minute interval date and time of the 30 minute predispatch interval that was processed by the constraint FCAS processor","examples":["2026/09/24 13:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Predispatch sequence number for the 30 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026092417","2026092418"],"unsigned_int":true,"num_int_bits":32},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 30 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026/09/24 12:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 30 minute predispatch case run number that has triggers the constraint FCAS processor run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, after the regulation/contingency split","examples":["0.189","0","78","203.15"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint, before the regulation/contingency split","examples":["0.189","0","78","203.15"],"is_float":true},"CONSTRAINT_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW enabled for this bid type within the constraint","examples":["22.48","0","35","437"],"is_float":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints summed LHS - aggregate LHS Solution values from the physical run from the PREDISPATCHCONSTRAINT table","examples":["-0.2657","21.68445","0","815"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Shadow price of constraint from the PREDISPATCHCONSTRAINT table from the physical run.","examples":["0.01","0","3.12"],"is_float":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted marginal value of the constraint for FPP recovery (blank for constraints without REG terms)","examples":["0.34","0","3.12"],"is_float":true},"REGION_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The regional payment allocated to the constraint for the interval pro-rated based on marginal value ratios over the binding constraints for that service in that region (this is an intermediate calculation to get to the base cost)","examples":["0.01","0","78","101.575"],"is_float":true},"REGIONAL_ENABLEMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The dispatched MW for the bid type inside the region from the physical run of the PREDISPATCHREGIONSUM table","examples":["0.27","0","1","281"],"is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraints RHS value used in the solution - may be either dynamic (calculated) or static from the physical run from the PREDISPATCHCONSTRAINT table","examples":["-0.0001","8.47886","0","1390"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Bid type prices for the region coming from the pricing run of the PREDISPATCHREGIONSUM table","examples":["0.01","0","1","3"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD_FCAS_REQ_CONSTRAINT%23FILE02%23202609010000.zip","manifest_summary":{"max_files_per_month":27,"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":635947051,"decompressed_size_all_time":1060638099840},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a 30 minute predispatch run"},"PD_FCAS_REQ_RUN":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"FCAS_REQ_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#7"],"comment":"The constraint FCAS processor run details. This enhanced output table format is established for the constraint FCAS processor release required for the Frequency Performance Payments (FPP) release. This enhanced output is hierarchical in nature, with the parent *_FCAS_REQ_RUN table holding the details about the triggering case run and time, and the child *_FCAS_REQ_CONSTRAINT table holding the constraint level details of FCAS costs / prices.","primary_keys":["PREDISPATCHSEQNO","RUN_DATETIME","RUNNO"],"columns":{"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Predispatch sequence number for the 30 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026083141","2026092132"],"unsigned_int":true,"num_int_bits":32},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The run date and time of the 30 minute predispatch case that triggers the constraint FCAS processor run","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":true,"comment":"The 30 minute predispatch case run number that has triggers the constraint FCAS processor run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last time the constraint FCAS processor was executed for this case run time.","examples":["2026/09/01 00:02:40"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PD_FCAS_REQ_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":12},"last_month":{"year":2026,"month":9},"compressed_size_per_month":13264,"decompressed_size_all_time":33752440},"visibility":"Public","trigger":"Public at the completion of a constraint FCAS processor run for a 30 minute predispatch run"},"PD_INTERMITTENT_FCST_TRK":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"PD_INTERMITTENT_FCST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#13"],"comment":"Uniquely tracks which Intermittent Generation forecast run (from INTERMITTENT_GEN_FCST_RUN) was used for the DUID in which Pre-dispatch run.","primary_keys":["DUID","PREDISPATCHSEQNO"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier, tracks to INTERMITTENT_GEN_FCST_RUN.DUID.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of Pre-dispatch run in the form YYYYMMDDPP with 01 at 04:30.","unsigned_int":true,"num_int_bits":32},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Priority of the forecast run used for the PD run, tracks to INTERMITTENT_GEN_FCST_RUN.FORECAST_PRIORITY.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime, unless a forecast run is missed, in this case the previous run is used. Tracks to INTERMITTENT_GEN_FCST_RUN.FORECAST_RUN_DATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Submission datetime of the forecast run used for the PD run, tracks to INTERMITTENT_GEN_FCST_RUN.OFFERDATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Provider of the forecast run used for the PD run, tracks to INTERMITTENT_GEN_FCST_RUN.PROVIDERID.","is_categorical":true}},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes when a new Pre-dispatch run is published"},"PD_ROOFTOP_PV_FCST_TRK":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"PD_ROOFTOP_PV_FCST_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#19"],"comment":"Uniquely tracks which Rooftop PV forecast run (from ROOFTOP_PV_FCST_RUN) was used for the Area in which Pre-dispatch run.","primary_keys":["AREAID","PREDISPATCHSEQNO"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Area identifier aligning with the load forecasting areas, tracks to ROOFTOP_PV_FCST_RUN.AREAID."},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of Pre-dispatch run in the form YYYYMMDDPP with 01 at 04:30.","unsigned_int":true,"num_int_bits":32},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Priority of the forecast run used for the PD run, tracks to ROOFTOP_PV_FCST_RUN.FORECAST_PRIORITY.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime (interval ending) when the forecast run is valid. It would align with run_datetime, unless a forecast run is missed, in this case the previous run will be used. Tracks to ROOFTOP_PV_FCST_RUN.FORECAST_RUN_DATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Submission datetime of the forecast run used for the PD run, tracks to ROOFTOP_PV_FCST_RUN.OFFERDATETIME.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Provider identifier of the forecast run used for the PD run, tracks to ROOFTOP_PV_FCST_RUN.PROVIDERID.","is_categorical":true}},"visibility":"Public","trigger":"Every 30 minutes when a new Pre-dispatch run is published"},"PERDEMAND":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"PERIOD","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#121"],"comment":"PERDEMAND sets out the regional demands and MR schedule data for each half-hour period. PERDEMAND is a child table to RESDEMANDTRK.","description":"The RESDEMANDTRK and PERDEMAND tables have a parent/child relationship,\nand define forecast regional demands since market start. RESDEMANDTRK\ndefines the existence and versioning information of a forecast for a\nspecific region and trading date. PERDEMAND defines the numerical\nforecast values for each trading interval of a the trading day for that\nregion. A complete trading day forecast for one region consists of one\nRESDEMANDTRK record and 48 PERDEMAND records.\n\nSource\n\nPERDEMAND updates whenever AEMO issues a new or revised forecast. ST\nPASA forecasts update seven days at a time. Predispatch updates one\ndate.\n\nVolume\n\n1296000 rows per year\n\nNote\n\nIn the context of a mandatory restrictions event the forecast schedule\n(MW) of restrictions are reported through the RESDEMANDTRK and PERDEMAND\ntables using the new field PerDemand.MR_Schedule. The relationship\nbetween fields and mandatory restriction terms for the 50% probability\nof exceedence forecast are:\n\n· UnRestricted Profile = ResDemand + MR_Schedule\n\n· Restricted Profile = ResDemand","primary_keys":["OFFERDATE","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date record issued","examples":["2026/08/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Half hourly trading intervals from 04:30.","examples":["1","48"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date of forecast up to 7 days ahead.","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The version of the RESDEMAND file for this date","examples":["2","48"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEMAND10PROBABILITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Demand level for a 10% probability of exceedance","examples":["4553","9671"],"is_integer":true,"num_int_bits":64},"DEMAND90PROBABILITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Demand at 90% probability of exceedance","examples":["4128","8762"],"is_integer":true,"num_int_bits":64},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Market date the forecast is made for. First date of the 7 days.","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/25 12:57:10"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_SCHEDULE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MR_Schedule = Unrestricted Demand - POE","examples":["0"],"is_integer":true,"num_int_bits":32},"RESDEMAND":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Base Demand forecast for period","examples":["4340","9217"],"is_integer":true,"num_int_bits":64}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PERDEMAND%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":17063278,"decompressed_size_all_time":38408971340},"visibility":"Public","trigger":"When AEMO issues a new or revised forecast. ST PASA forecasts update seven days at a time. Predispatch updates one date."},"PEROFFER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#843"],"comment":"PEROFFER contains the half-hourly period details of daily bids and rebids, to be used in conjunction with DAYOFFER. These views provide period varying details such as rate of change up (ROCUP), rate of change down (ROCDOWN) and band quantities (BANDAVAIL from 1 to 10).\nPEROFFER is a child table of DAYOFFER.","description":"Status\n\nPEROFFER is obsolete. please see BIDPEROFFER. For a transition period,\nPEROFFER data continued to exist, being based on BIDPEROFFER.\n\nSource\n\nPEROFFER is obsolete; confidential data was updated for each bid and\nrebid, with full visibility of rest of market were updated daily as part\nof next day data.","unused":true,"primary_keys":["DUID","OFFERDATE","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date made","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:00am","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of offer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BANDAVAIL1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 1","is_integer":true,"num_int_bits":32},"BANDAVAIL2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 2","is_integer":true,"num_int_bits":32},"BANDAVAIL3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 3","is_integer":true,"num_int_bits":32},"BANDAVAIL4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 4","is_integer":true,"num_int_bits":32},"BANDAVAIL5":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 5","is_integer":true,"num_int_bits":32},"BANDAVAIL6":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 6","is_integer":true,"num_int_bits":32},"BANDAVAIL7":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 7","is_integer":true,"num_int_bits":32},"BANDAVAIL8":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 8","is_integer":true,"num_int_bits":32},"BANDAVAIL9":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 9","is_integer":true,"num_int_bits":32},"BANDAVAIL10":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 10","is_integer":true,"num_int_bits":32},"FIXEDLOAD":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW. A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXAVAIL":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum plant availability","is_float":true},"MR_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Offer amount","is_integer":true,"num_int_bits":32},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The physical plant capability including any capability potentially available within 24 hours.","is_integer":true,"num_int_bits":64},"ROCDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for lower","is_integer":true,"num_int_bits":32},"ROCUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/min for raise","is_integer":true,"num_int_bits":32},"SELFDISPATCH":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private & Public Next-Day"},"PEROFFER_D":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#854"],"comment":"PEROFFER_D contains the half-hourly period details of daily bids and rebids, to be used in conjunction with DAYOFFER_D. These views provide period varying details such as rate of change up (ROCUP), rate of change down (ROCDOWN) and band quantities (BANDAVAIL from 1 to 10).\nPEROFFER_D is a child table of DAYOFFER_D.","description":"Not in Use - discontinued 16/11/2003\n\nStatus\n\nPEROFFER and its related views are obsolete. please see BIDPEROFFER\nviews. For a transition period, the PEROFFER views exist, being based on\nthe BIDPEROFFER table.\n\nSource\n\nPEROFFER is obsolete; confidential data was updated for each bid and\nrebid, with full visibility of rest of market were updated daily as part\nof next day data.","unused":true,"primary_keys":["DUID","OFFERDATE","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Offer date made","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Market date starting at 04:00am","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of offer","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BANDAVAIL1":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 1","is_integer":true,"num_int_bits":32},"BANDAVAIL2":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 2","is_integer":true,"num_int_bits":32},"BANDAVAIL3":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 3","is_integer":true,"num_int_bits":32},"BANDAVAIL4":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 4","is_integer":true,"num_int_bits":32},"BANDAVAIL5":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 5","is_integer":true,"num_int_bits":32},"BANDAVAIL6":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 6","is_integer":true,"num_int_bits":32},"BANDAVAIL7":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 7","is_integer":true,"num_int_bits":32},"BANDAVAIL8":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 8","is_integer":true,"num_int_bits":32},"BANDAVAIL9":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 9","is_integer":true,"num_int_bits":32},"BANDAVAIL10":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Availability at price band 10","is_integer":true,"num_int_bits":32},"FIXEDLOAD":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Fixed unit output MW. A value of zero means no fixed load so the unit is dispatched according to bid and market (rather than zero fixed load)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXAVAIL":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum plant availability","is_float":true},"MR_CAPACITY":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mandatory Restriction Offer amount","is_integer":true,"num_int_bits":32},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The physical plant capability including any capability potentially available within 24 hours.","is_integer":true,"num_int_bits":64},"ROCDOWN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/Min for lower","is_integer":true,"num_int_bits":32},"ROCUP":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"MW/min for raise","is_integer":true,"num_int_bits":32},"SELFDISPATCH":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Public"},"PMS_GROUP":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PMS_GROUP","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#213"],"comment":"Entity table for group","primary_keys":["GROUPID"],"columns":{"GROUPID":{"sql_type":"NUMBER(20,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Abstract identifier for the group","examples":["3","283"],"is_integer":true,"num_int_bits":128},"CREATEDDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record was created","examples":["2021/09/21 13:38:51.717"],"parse_csv_as_string":true,"is_ms_datetime":true},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record was last changed","examples":["2021/09/21 13:38:51.717"],"parse_csv_as_string":true,"is_ms_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PMS_GROUP%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":4528,"decompressed_size_all_time":956780},"visibility":"Public","trigger":"When the record is created or updated"},"PMS_GROUPNMI":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PMS_GROUPNMI","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#219"],"comment":"Describe the NMIs that a group uses to provide its service","primary_keys":["GROUPNMIID"],"indexes":[["GROUPID","NMI"]],"columns":{"GROUPNMIID":{"sql_type":"NUMBER(20,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Record Identifier of the NMI within a Group. When data is updated, existing record identifier is terminated, and new record identifier(s) are allocated.","is_integer":true,"num_int_bits":128},"APPROVEDDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date which this record was approved","parse_csv_as_string":true,"is_ms_datetime":true},"BASELINEMETHODOLOGYID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Baseline methodology to be used for the PoL and Baseline assessment of the NMI"},"ENDDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date for which this version is effective to. Will be set to current day plus one if it is the current active record or past date if the record has been superseded/ended.","parse_csv_as_string":true,"is_ms_datetime":true},"GROUPID":{"sql_type":"NUMBER(20,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Group id of the Group which the NMI belongs in.","is_integer":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time which record was last changed","parse_csv_as_string":true,"is_ms_datetime":true},"MRC":{"sql_type":"NUMBER(10,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum responsive component for the NMI","is_float":true},"MRCREASON":{"sql_type":"VARCHAR2(500)","pl_type":"str","mandatory":false,"comment":"Reason for the MRC"},"NERRGROUPPREMISES":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Specifies whether NMI is in a NERR aggregated premises (TRUE = 1/FALSE = 0)","is_integer":true,"num_int_bits":8},"NMI":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"National Meter Identifier linked to the group."},"RETAILCUSTOMER":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Retail customer of the NMI"},"SITENAME":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Site name"},"STARTDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Effective date of when this service started operation","parse_csv_as_string":true,"is_ms_datetime":true},"SUSPENDED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Indicates whether the NMI has been suspended from use. (TRUE = 1/FALSE = 0)","is_integer":true,"num_int_bits":8},"UNAVAILABLE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Indicates whether the NMI is unavailable for use. (TRUE = 1/FALSE = 0)","is_integer":true,"num_int_bits":8},"VERSIONFROM":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date for which this version is effective from","parse_csv_as_string":true,"is_ms_datetime":true},"VERSIONTO":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date for which this version is effective to. Will be set to current day plus one if it is the current active record or past date if the record has been superseded/ended.","parse_csv_as_string":true,"is_ms_datetime":true}},"visibility":"Private","trigger":"When the NMIs are created or updated"},"PMS_GROUPSERVICE":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"PMS_GROUPSERVICE","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#227"],"comment":"Describe the services a group provides and its relation to a market","primary_keys":["GROUPSERVICEID"],"indexes":[["ENTITYID","GROUPID"]],"columns":{"GROUPSERVICEID":{"sql_type":"NUMBER(20,0)","pl_type":"pl.Int128","mandatory":true,"comment":"Record identifier of the Service allocated to the Group. When data is updated, existing record identifier is terminated, and new record identifier(s) are allocated.","examples":["9","855"],"is_integer":true,"num_int_bits":128},"APPROVEDDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date which this record was approved","examples":["2021/10/22 10:36:55.207"],"parse_csv_as_string":true,"is_ms_datetime":true},"ENDDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Effective date of when this service ended operation. Will be set to max date 9999/12/31 23:59:59.999 until its service ends or a change to the service is required.","examples":["9999/12/31 23:59:59.997"],"parse_csv_as_string":true,"is_ms_datetime":true},"ENTITYID":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Describe the entity ID in the market that it will be operating in. Will only contain the DUID of the group initially.","examples":["DRVIOT06","DRVIOT07","DRVISB01","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02"]},"ENTITYTYPE":{"sql_type":"VARCHAR2(50)","pl_type":"pl.Categorical","mandatory":false,"comment":"Describes the entity that is operating. Will only be WDRU initially.","examples":["WDRU"]},"GROUPID":{"sql_type":"NUMBER(20,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Group id of the Group where the Service is attached to.","examples":["3","273"],"is_integer":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time which record was last changed","examples":["2026/10/08 17:00:02.470"],"parse_csv_as_string":true,"is_ms_datetime":true},"MARKET":{"sql_type":"VARCHAR2(50)","pl_type":"str","mandatory":false,"comment":"Market that this group is operating its service in. Will only be NEM initially.","examples":["NEM"]},"MAXIMUMRAMPRATEPERMIN":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"Maximum ramp rate MW per minute of the service.","examples":["1","40"],"is_integer":true,"num_int_bits":64},"MRC":{"sql_type":"NUMBER(10,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum responsive component for the service offering","examples":["1","200"],"is_float":true},"MRCREASON":{"sql_type":"VARCHAR2(500)","pl_type":"str","mandatory":false,"comment":"Reason for the MRC."},"REGION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Region the group is operating this service in One of NSW1, QLD1, VIC1, SA1 or TAS1","examples":["NSW1","QLD1","SA1","VIC1"]},"SERVICETYPE":{"sql_type":"VARCHAR2(50)","pl_type":"pl.Categorical","mandatory":false,"comment":"Service that this group is operating. Will be only be ENERGY initially","examples":["ENERGY"]},"STARTDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Effective date of when this service started operation","examples":["2021/10/24 00:00:00.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"VERSIONFROM":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date for which this version is effective from.","examples":["2021/10/22 10:36:55.207"],"parse_csv_as_string":true,"is_ms_datetime":true},"VERSIONTO":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date for which this version is effective to. Will be set to max date 9999/12/31 23:59:59.999 until this version ends or a change to the version is required.","examples":["2022/06/03 17:30:14.690"],"parse_csv_as_string":true,"is_ms_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PMS_GROUPSERVICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":4843,"decompressed_size_all_time":889520},"visibility":"Public","trigger":"When the group service data is created or updated"},"PREDISPATCHBIDTRK":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#874"],"comment":"PREDISPATCHBIDTRK contains an audit trail of bids used in each predispatch run. Where predispatch is over 2 days, two bids are listed.","description":"Status\n\nPREDISPATCHOFFERTRK and related views are obsolete. Please see tables\nand views related to BIDPEROFFER.\n\nSource\n\nOwn (confidential) data shows via inserts with every thirty-minute\npredispatch. Daily update after close of day shows all market bids for\nthe closed day.\n\nPeriod date and time","unused":true,"primary_keys":["DUID","PERIODID","PREDISPATCHSEQNO"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"],["DUID","SETTLEMENTDATE"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","unsigned_int":true,"num_int_bits":32},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"Bid type (daily, default or rebid)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Period date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Offer date for bid","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Market Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Version no of offer for the offer date","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private & Public Next-Day","trigger":"Updated daily"},"PREDISPATCHBLOCKEDCONSTRAINT":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"BLOCKED_CONSTRAINTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#42"],"comment":"PREDISPATCH Blocked Constraints lists any constraints that were blocked in a Predispatch run. If no constraints are blocked, there will be no rows for that predispatch run.","primary_keys":["CONSTRAINTID","PREDISPATCHSEQNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint identifier (synonymous with GenConID)","examples":["V^SML_BUDP_3"],"is_categorical":true},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026071446","2026071523"],"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHBLOCKEDCONSTRAINT%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2025,"month":2},"last_month":{"year":2026,"month":7},"has_missing_months":true,"compressed_size_per_month":490,"decompressed_size_all_time":75210},"visibility":"Public","trigger":"Every 30 minutes"},"PREDISPATCHCASESOLUTION":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"CASE_SOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#48"],"comment":"PREDISPATCHCASESOLUTION provides information relating to the complete predispatch run. The fields provide an overview of the dispatch run results allowing immediate identification of conditions such as energy or FCAS deficiencies.","description":"PREDISPATCHCASESOLUTION data is public, so is available to all\nparticipants.\n\nSource\n\nPREDISPATCHCASESOLUTION updates every half-hour.\n\nVolume\n\nApproximately 48 records per day.","primary_keys":["PREDISPATCHSEQNO","RUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026092140"],"unsigned_int":true,"num_int_bits":32},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Predispatch run no, normally 1.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this Pre-Dispatch case includes an intervention pricing run: 0 = case does not include an intervention pricing run, 1 = case does include an intervention pricing run. This field has a default value of 0 and is not nullable","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHCASESOLUTION."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NONPHYSICALLOSSES":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Non-Physical Losses algorithm invoked during this run","examples":["0"],"is_integer":true,"num_int_bits":8},"SOLUTIONSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"If non-zero indicated one of the following conditions: 1 = Supply Scarcity, Excess generation or constraint violations, -X = Model failure","examples":["1","22"],"is_integer":true,"num_int_bits":8},"SPDVERSION":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Current version of SPD"},"TOTAL5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 5 minute ancillary service region violations","is_float":true},"TOTAL6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 6 second ancillary service region violations","is_float":true},"TOTAL60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of 60 second ancillary service region violations","is_float":true},"TOTALAREAGENVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Region Demand violations","examples":["0"],"is_float":true},"TOTALASPROFILEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of ancillary service trader profile violations","examples":["0"],"is_float":true},"TOTALENERGYCONSTRVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of Energy Constrained unit offer violations.","examples":["0","20"],"is_float":true},"TOTALENERGYOFFERVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of unit summated offer band violations","examples":["0"],"is_float":true},"TOTALGENERICVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total generic constraint violations","examples":["0.002","0","10","1763"],"is_float":true},"TOTALINTERCONNECTORVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total interconnector violations","examples":["0"],"is_float":true},"TOTALOBJECTIVE":{"sql_type":"NUMBER(27,10)","pl_type":"pl.Float64","mandatory":false,"comment":"The Objective function from the LP","examples":["-1345204.551","348809.312","1183428804","84699544014.542"],"is_float":true},"TOTALRAMPRATEVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total ramp rate violations","examples":["0.306","0","0.79"],"is_float":true},"TOTALREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total of Regulation ancillary service region violations","is_float":true},"TOTALUNITMWCAPACITYVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total unit capacity violations","examples":["0.4","0","7","1698"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHCASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":31920,"decompressed_size_all_time":43805100},"visibility":"Public","trigger":"Every 30 minutes"},"PREDISPATCHCONSTRAINT":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"CONSTRAINT_SOLUTION","VERSION":5}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#57"],"comment":"PREDISPATCHCONSTRAINT sets out constraints that are binding in each predispatch run and interconnector constraints (whether binding or not). Only binding and interconnector constraints are reported. Binding contracts have marginal value greater than $0. Interconnector constraints are listed so RHS values can be reported for ST PASA.\nConstraint solutions only report fixed loading /MR constraints on the next day.","description":"PREDISPATCHCONSTRAINT data is confidential on the day of creation, and\npublic to all participants after the end of the market day.\n\nSource\n\nPREDISPATCHCONSTRAINT updates with every thirty-minute predispatch run.\n\nNote\n\nThe PERIODID columns in tables PREDISPATCHCONSTRAINT and\nPREDISPATCH_FCAS_REQ have no consistent relationship with the other\nPERIODID values in the other tables in the PRE-DISPATCH package (such as\nPREDISPATCHPRICE). AEMO and many Participants appreciate the data model\nis inconsistent, but the cost of changing existing systems has been\njudged as being unjustifiable. An additional field DATETIME was added to\nallow joins between these data sets.","primary_keys":["CONSTRAINTID","DATETIME"],"indexes":[["PREDISPATCHSEQNO"],["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic constraint identifier","examples":["#BBATTERY1_E1","#BBATTERY1_E2","#BRAEMAR1_E","#CLRKCWF1_E1","#CLRKCWF2_E1","#COHUNSF1_E1","#ERB02_E1","#ERB02_E2","#GREENB1_E1","#GREENB1_E2","#LANCSF1_E1","#LNGS2_E1","#MCINTYR1_E1","#MOUSF1_E","#MTGELWF1_E","#RANGEB1_E1","#RANGEB1_E2","#SMCSF1_E","#SSE_PPCCGT_20","#WANDSF1_E","#WDBESS1_E1","#WDBESS1_E2","C_N_LIMOSF11_220","C_N_MULWASF1_025","C_N_NESBESS_150_G","C_N_NESBESS_150_L","C_N_QUORNP_019_L_H","C_N_QUORNP_080_G_H","C_N_WILLBES1_075_G","C_N_WILLBES1_075_L","C_N_WTAHB1_850_G","C_N_WTAHB1_850_L","C_Q_BRDDBES1_181_G","C_Q_BRDDBES1_181_L","C_Q_BRDDSF01_296","C_Q_BUSF1_078","C_Q_KIDSPHG1_000","C_Q_KIDSPHG2_000","C_Q_KIDSPHL1_000","C_Q_KIDSPHL2_000","C_Q_MUCRKSF1_120","C_Q_SNB01_250_L","C_Q_SNB01_260_G","C_Q_SNB02_250_L","C_Q_SNB02_260_G","C_Q_STABESS1_100_G","C_Q_STABESS1_100_L","C_Q_SWANBBF1_250_G","C_Q_SWANBBF1_250_L","C_Q_WAMBOWF1_245","C_Q_WAMBOWF2_099","C_Q_WANDSF2_060","C_Q_WDBESS2_255_G","C_Q_WDBESS2_255_L","C_Q_WOOLES1_111_G","C_Q_WOOLES1_118_L","C_S_CGBESS01_060_G","C_S_CGBESS01_060_L","C_S_LGAPBS1_009_G","C_S_LGAPBS1_013_L","C_S_SMFBESS1_040_G","C_S_SMFBESS1_040_L","C_S_SMFBESS2_040_G","C_S_SMFBESS2_040_L","C_V_GPWFWST_462","C_V_MRNBESS1_168_G","C_V_MRNBESS1_168_L","C_V_PLBESS1_007_G","C_V_PLBESS1_007_L","DATASNAP_DFS_LS","DATASNAP_DFS_NCAN","DATASNAP_DFS_NCWEST","DATASNAP_DFS_NNTH","DATASNAP_DFS_NSYD","DATASNAP_DFS_QCEN","DATASNAP_DFS_QCIND","DATASNAP_DFS_QFNQ","DATASNAP_DFS_QNTH","DATASNAP_DFS_QROSS","DATASNAP_DFS_QSTHE","DATASNAP_DFS_QSTHW","DATASNAP_DFS_Q_BCCP","DATASNAP_DFS_Q_BCRG","DATASNAP_DFS_Q_CLST","DATASNAP_DFS_Q_CLWU","DATASNAP_DFS_Q_LCCP","DATASNAP_DFS_Q_RGLC","DATASNAP_DFS_Q_TAMR","DATASNAP_DFS_Q_TAMR2","DATASNAP_DFS_SADL","DATASNAP_DFS_SNTH","DATASNAP_DFS_SRIV","DATASNAP_DFS_SSE","DATASNAP_DFS_SWNSW","DATASNAP_DFS_TNTH","DATASNAP_DFS_TNWEST","DATASNAP_DFS_TWCST","DATASNAP_DFS_T_FASH1","DATASNAP_DFS_T_GOCS1","DATASNAP_DFS_T_HAGT1","DATASNAP_DFS_T_PMHA1","DATASNAP_DFS_T_PMHA3","DATASNAP_DFS_T_SHGT","DATASNAP_DFS_T_SHPM","DATASNAP_DFS_T_TATU","DATASNAP_DFS_T_WALE","DATASNAP_DFS_VIC_SG","DATASNAP_DFS_VMEL","DATASNAP_DFS_V_BABE","DATASNAP_N_AR_LS_TE","DATASNAP_N_MUSW","DATASNAP_N_TAM","DATASNAP_PDID_1","DATASNAP_PDID_2","DATASNAP_PV_NSW","DATASNAP_PV_QLDCEN","DATASNAP_PV_QLDNORTH","DATASNAP_PV_QLDSOUTH","DATASNAP_PV_SA","DATASNAP_PV_TASNORTH","DATASNAP_PV_TASSOUTH","DATASNAP_PV_VIC","DATASNAP_TE_967_1","DATA_MMS_ALERT1","DSNAP_BU_PST1_TAP","DSNAP_BU_PST2_TAP","DSNAP_BU_PST3_ANG","DSNAP_BU_PST3_TAP","DSNAP_BU_PST4_TAP","DSNAP_BU_PST5_TAP","DSNAP_DFS_N_ARTW","DSNAP_DFS_N_AVMN","DSNAP_DFS_N_BYCR","DSNAP_DFS_N_BYSW","DSNAP_DFS_N_CNYS","DSNAP_DFS_N_DTMN","DSNAP_DFS_N_LDTW","DSNAP_DFS_N_LTMS","DSNAP_DFS_N_MNYS","DSNAP_DFS_N_MSUT","DSNAP_DFS_N_TWUL","DSNAP_DFS_V_BABE_5M","DSNAP_DFS_V_BAML","DSNAP_DFS_V_BAML_5M","DSNAP_DFS_V_DDMB","DSNAP_DFS_V_DDMS","DSNAP_DFS_V_DDSM","DSNAP_DFS_V_EPTT","DSNAP_DFS_V_MLGT1","DSNAP_DFS_V_MLGT2","DSNAP_DFS_V_ROYP","DSNAP_INFO_NSW_INER","DSNAP_INFO_QLD_INER","DSNAP_INFO_SA_INER","DSNAP_INFO_TAS_INER","DSNAP_INFO_TNTH_INER","DSNAP_INFO_VIC_INER","DSNAP_LRHS_1","DSNAP_LRHS_2","DSNAP_MLGT_MLGT_CONT","DSNAP_MLGT_MLGT_HC","DSNAP_MLGT_MLGT_LB","DSNAP_MLNK_RAT_LIM","DSNAP_N::N_NIL_LTWG","DSNAP_N_MSL_BESS_CHG","DSNAP_Q>>MITUM","DSNAP_Q>WOCY_1","DSNAP_Q>WOGP","DSNAP_Q^^NIL_TR_CLHA","DSNAP_Q^^NIL_TR_TRBK","DSNAP_Q_BKSP838","DSNAP_Q_MSL_BESS_CHG","DSNAP_Q_TR_1500","DSNAP_SA_ROCOF","DSNAP_S_MSL_BESS_CHG","DSNAP_T_TV_BL_DYN","DSNAP_T_VT_BL_DYN","DSNAP_VS_600_TEST","DSNAP_V^^_NIL_SWVIC1","DSNAP_V^^_NIL_SWVIC2","DSNAP_V^^_NIL_SWVIC3","DSNAP_V^^_NIL_SWVIC4","DSNAP_V_MSL_BESS_CHG","D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_NIL_SNOW_N+S_100","D_Q+BIP_ML_L1","D_Q+BIP_ML_L6","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_WF_TG_R1","D_V_HEYWOOD_OFGS_1","D_V_HEYWOOD_OFGS_2","D_V_HEYWOOD_OFGS_3","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+MREH_TG_R1","F_I+MREH_TG_R5","F_I+MREH_TG_R6","F_I+MREH_TG_R60","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_ERB_TL_L1","F_I+NIL_ERB_TL_L5","F_I+NIL_ERB_TL_L6","F_I+NIL_ERB_TL_L60","F_I+NIL_LDBES_TL_L1","F_I+NIL_LDBES_TL_L5","F_I+NIL_LDBES_TL_L6","F_I+NIL_LDBES_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+NIL_MREH_TL_L1","F_I+NIL_MREH_TL_L5","F_I+NIL_MREH_TL_L6","F_I+NIL_MREH_TL_L60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++ERB_TL_L1","F_MAIN++ERB_TL_L5","F_MAIN++ERB_TL_L6","F_MAIN++ERB_TL_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LDBES_TL_L1","F_MAIN++LDBES_TL_L5","F_MAIN++LDBES_TL_L6","F_MAIN++LDBES_TL_L60","F_MAIN++LREG_0210","F_MAIN++MREH_TG_R1","F_MAIN++MREH_TG_R5","F_MAIN++MREH_TG_R6","F_MAIN++MREH_TG_R60","F_MAIN++MREH_TL_L1","F_MAIN++MREH_TL_L5","F_MAIN++MREH_TL_L6","F_MAIN++MREH_TL_L60","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+ERB_TL_L1","F_MAIN+ERB_TL_L5","F_MAIN+ERB_TL_L6","F_MAIN+ERB_TL_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LDBES_TL_L1","F_MAIN+LDBES_TL_L5","F_MAIN+LDBES_TL_L6","F_MAIN+LDBES_TL_L60","F_MAIN+LREG_0210","F_MAIN+MREH_TG_R1","F_MAIN+MREH_TG_R5","F_MAIN+MREH_TG_R6","F_MAIN+MREH_TG_R60","F_MAIN+MREH_TL_L1","F_MAIN+MREH_TL_L5","F_MAIN+MREH_TL_L6","F_MAIN+MREH_TL_L60","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_Q++NIL_R1","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_Q_MEWV_823_R5","F_Q_MEWV_823_R5_P","F_Q_MEWV_823_R60","F_Q_MEWV_823_R60_P","F_Q_MEWV_823_R6_P","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_GHWF_TG_R6","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R60","F_T++NIL_WNWF_TG_R6","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_CHWF_TG_R6","F_T+NIL_FCSPS_R5","F_T+NIL_FCSPS_R6","F_T+NIL_FCSPS_R60","F_T+NIL_GHWF_TG_R6","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_MRWF_TG_R6","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R60","F_T+NIL_WNWF_TG_R6","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_AUFLS2_R6","F_T_NIL_MAXS_R1","F_T_NIL_MAXS_R5","F_T_NIL_MAXS_R6","F_T_NIL_MAXS_R60","F_T_NIL_MINP_R6","I_6F_NS_150","I_6F_SN_150","N::N_NIL_63","N::Q_BWMP_KC","N::Q_BWMP_LDMU","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N::Q_NIL_KC","N::Q_NIL_LDMU","N::Q_NIL_LDTW","N::Q_NIL_TNT","N::V_NIL_BWSW","N::V_NIL_MSDD","N::V_NIL_UTMS","N:V_NIL_BWRG","N:V_NIL_BYYS","N>94T_945_94K","N>94T_947_72","N>94T_94K1_945","N>>BWMP_23_22","N>>BWMP_81_31","N>>BWMP_81_82","N>>BWMP_82_81","N>>CHTX_966_87","N>>NIL_01_62","N>>NIL_060","N>>NIL_060_051","N>>NIL_07","N>>NIL_1","N>>NIL_16_18","N>>NIL_16_39","N>>NIL_16_3W","N>>NIL_16_76","N>>NIL_16_8","N>>NIL_18_16","N>>NIL_18_4_N","N>>NIL_18_4_S","N>>NIL_18_5_N","N>>NIL_18_5_S","N>>NIL_18_61","N>>NIL_18_8","N>>NIL_1_3","N>>NIL_1_3_LSC1_ON","N>>NIL_1_6X","N>>NIL_1_6X_LSC1_ON","N>>NIL_1_7","N>>NIL_1_7_LSC1_ON","N>>NIL_23_22","N>>NIL_23_25","N>>NIL_3","N>>NIL_33_34","N>>NIL_39","N>>NIL_39_11","N>>NIL_39_17","N>>NIL_3G","N>>NIL_3L","N>>NIL_3L_18_N","N>>NIL_3L_3J_N","N>>NIL_3L_3P_N","N>>NIL_3L_3W","N>>NIL_3L_5_N","N>>NIL_3_7","N>>NIL_3_7_LSC1_ON","N>>NIL_3_7_LSC2_ON","N>>NIL_4","N>>NIL_4_18_S","N>>NIL_4_5_N","N>>NIL_4_5_S","N>>NIL_4_61_N","N>>NIL_4_61_S","N>>NIL_4_6_S","N>>NIL_5_18_N","N>>NIL_5_18_S","N>>NIL_5_3J_N","N>>NIL_5_3L_N","N>>NIL_5_3P_N","N>>NIL_5_3W","N>>NIL_5_4_S","N>>NIL_5_61_N","N>>NIL_5_61_S","N>>NIL_5_6_S","N>>NIL_61_18","N>>NIL_61_3L","N>>NIL_61_3W","N>>NIL_61_4","N>>NIL_61_5","N>>NIL_64_65","N>>NIL_6M_66","N>>NIL_6X","N>>NIL_6X_1","N>>NIL_6X_3","N>>NIL_6X_9","N>>NIL_70_71","N>>NIL_76_77","N>>NIL_77_76","N>>NIL_7_1","N>>NIL_7_1_LSC1_ON","N>>NIL_7_3","N>>NIL_7_3_LSC1_ON","N>>NIL_7_3_LSC2_ON","N>>NIL_81","N>>NIL_81_31","N>>NIL_81_82_CLOSE","N>>NIL_81_82_OPEN","N>>NIL_82","N>>NIL_82_81_CLOSE","N>>NIL_82_81_OPEN","N>>NIL_83_84_CLOSE","N>>NIL_83_84_OPEN","N>>NIL_84_83_CLOSE","N>>NIL_84_83_OPEN","N>>NIL_84_88_S","N>>NIL_85_86_S","N>>NIL_86_85_N","N>>NIL_86_85_S","N>>NIL_86_8U_S","N>>NIL_86_N","N>>NIL_86_NIL_S","N>>NIL_88_84_N","N>>NIL_88_84_S","N>>NIL_8E_8C_S","N>>NIL_8U_86_S","N>>NIL_8_16","N>>NIL_8_18","N>>NIL_8_3W","N>>NIL_964_84_S","N>>NIL_964_88_S","N>>NIL_966/1_87_S","N>>NIL_967_89_S","N>>NIL_990","N>>NIL_991","N>>NIL_994","N>>NIL_996_62","N>>NIL_9W2_9W8","N>>NIL_9_18_N","N>>NIL_9_18_S","N>>NIL_9_6","N>>NIL_DPTX_HV","N>>NIL_DPTX_LV","N>>NIL_X3_060","N>>V_NIL_65","N>>V_NIL_65_66","N>>V_NIL_65_LTWG","N>>V_NIL_66","N>>V_NIL_66_65","N>>V_NIL_66_LTWG","N>N-NIL_JUTX_LV","N>N-NIL_TE_LOAD","N>NIL_051","N>NIL_64_S","N>NIL_6M_N","N>NIL_75_WOTX_72","N>NIL_8J_8C","N>NIL_901","N>NIL_945_947","N>NIL_947_94T","N>NIL_94B","N>NIL_94B_94M","N>NIL_94B_9ML","N>NIL_94K_1","N>NIL_94M","N>NIL_94T","N>NIL_94T_72","N>NIL_94T_75","N>NIL_94T_7J","N>NIL_94T_947","N>NIL_966/1","N>NIL_967_89","N>NIL_969","N>NIL_96C_87","N>NIL_973","N>NIL_977_976","N>NIL_983_987","N>NIL_993","N>NIL_997/1_3G","N>NIL_997/2_3G","N>NIL_997/2_99A","N>NIL_997_99A","N>NIL_998","N>NIL_998_18","N>NIL_999","N>NIL_999_9GL","N>NIL_999_S","N>NIL_99F","N>NIL_99U","N>NIL_9GL","N>NIL_9GM","N>NIL_9J5/1","N>NIL_9J5/2","N>NIL_9J6","N>NIL_9ML","N>NIL_9R1","N>NIL_9R4","N>NIL_9R4_62","N>NIL_9R4_99A","N>NIL_9R4_9R3","N>NIL_9R5","N>NIL_9R5_9R6","N>NIL_9R6","N>NIL_9R6_991","N>NIL_9R6_9R5","N>NIL_9U3","N>NIL_9U9_9U8","N>NIL_BHTX_HV","N>NIL_BHTX_LV","N>NIL_CLDP","N>NIL_COTX_LV","N>NIL_LSDU","N>NIL_MBDU","N>NIL_MLTX_LV","N>NIL_MORTX_LV","N>NIL_PKTX_LV","N>NIL_X2","N>NIL_YSTX_LV","N>Q-NIL_757_758","NQ_950_TEST","NRM_NSW1_QLD1","NRM_NSW1_VIC1","NRM_QLD1_NSW1","NRM_SA1_VIC1","NRM_TAS1_VIC1","NRM_VIC1_NSW1","NRM_VIC1_SA1","NRM_VIC1_TAS1","N^^N_NIL_1","N^^N_NIL_WGLT","N^^N_NIL_X5_BEKG","N^^N_NIL_X5_BESH","N^^Q_NIL_CPP_3","N^^Q_NIL_CPP_4","N^^Q_NIL_KPP_1","N^^Q_NIL_MAXGEN","N^^Q_NIL_MPP_1","N^^Q_NIL_MPP_2","N^^Q_NIL_TNPS1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_FINLEYSF_CAP_66","N_NIL_TE_A","N_NIL_TE_B","N_STR_FINLYSF1_49_I","N_WDR_NO_SCADA","Q:NIL_CS","Q>>NIL_MRTX4_MRTX5","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q>NIL_BCCP_CLWU","Q>NIL_BCCP_LCCP","Q>NIL_BCRG_BCCP","Q>NIL_BCRG_CLWU","Q>NIL_BCST_BCST","Q>NIL_BI_FB","Q>NIL_CLBTX_CLBTX","Q>NIL_CLWU_BCRG","Q>NIL_CLWU_LCCP","Q>NIL_CPWU_CLWU","Q>NIL_DRLCLB_NIL","Q>NIL_EMCM_6056","Q>NIL_LCCP_BCCP","Q>NIL_LCCP_CLWU","Q>NIL_MRTA_C","Q>NIL_MUTE_757","Q>NIL_MUTE_758","Q>NIL_MUTX_MUTX","Q>NIL_PWSP_WOSP","Q>NIL_RGLC_BCCP","Q>NIL_RGLC_CLWU","Q>NIL_TV66","Q>NIL_WOPW_WOSP","Q>NIL_WOSP_PWSP","Q>NIL_WOSP_WOPW","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","QN_1400_TEST","Q^CN_FDR-060","Q^CN_GT-090","Q^CS_-080","Q^NIL_CN_FDR","Q^NIL_CN_GT","Q^NIL_CS","Q^NIL_FNQ_8905","Q^NIL_GC","Q^^NIL_TR_CLHA","Q^^NIL_TR_TRBK","Q^^N_NIL_SRAR","Q^^TR_CLHA_-050","Q^^TR_CLHA_-350","Q^^TR_TRBK_-050","Q^^TR_TRBK_-100","Q_CS_2000","Q_KEP-HYB_50MW","Q_KIDSPHG1_ZERO","Q_KIDSPHG2_ZERO","Q_KIDSPHL1_ZERO","Q_KIDSPHL2_ZERO","Q_MEWV_823_WIP1","Q_MEWV_823_WIV1","Q_STR_NIL_CLRSF1","Q_STR_NIL_CSPVPS1","Q_STR_NIL_DAYDSF1","Q_STR_NIL_HAMISF1","Q_STR_NIL_HAUGHT11","Q_STR_NIL_HAYMSF1","Q_STR_NIL_KABANWF1","Q_STR_NIL_KEP","Q_STR_NIL_KSP1","Q_STR_NIL_MEWF1","Q_STR_NIL_RRSF1","Q_STR_NIL_RUGBYR1","Q_STR_NIL_SMCSF1","Q_STR_NIL_WHITSF1","S-NIL_WTPT_SC+INV_1","S-NIL_WTPT_SC+INV_2","S-OUT_WTPT_SC+INV_1","S-OUT_WTPT_SC+INV_2","S::V_NIL_TBSE_1","S:VS_800","S:VS_900_HY_TEST","S:V_650","S:V_700_HY_TEST","S>>HUWT_BRTX_MNWT","S>>HUWT_BWPA_BRTW","S>>HUWT_BWPA_TWPA","S>>HUWT_RBTU_WEWT","S>>NIL_BGBW_BRTW","S>>NIL_BRTW_WEMW4","S>>NIL_BRTW_WTTP","S>>NIL_BRTX_WEMW4","S>>NIL_BRTX_WTTP","S>>NIL_BWMP_BRTW","S>>NIL_BWMP_RBTU","S>>NIL_BWMP_TPRS","S>>NIL_BWMP_TWPA","S>>NIL_BWMP_WEMW4","S>>NIL_BWMP_WTTP","S>>NIL_CNRB_WEMW4","S>>NIL_HUBG-T_WEWT","S>>NIL_LKDV_WEWT","S>>NIL_MKRB_WEMW4","S>>NIL_RBNW1_MWP1NWB","S>>NIL_RBNW1_RBMWP3","S>>NIL_RBTU_BRTW","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_TWPA","S>>NIL_RBTU_WEWT","S>>NIL_RBTU_WTTP","S>>NIL_RBTX1_WTWE","S>>NIL_RBTX_RBTX_1","S>>NIL_RBTX_RBTX_2","S>>NIL_SETB_SETB_1","S>>NIL_TBSE_PWSE_1","S>>NIL_TBSE_TBSE_1","S>>NIL_TBTU_TBMO_1","S>>NIL_TBTU_TBTU_1","S>>NIL_TBTX4_TBMO_1","S>>NIL_TPWTX_TPDR","S>>NIL_TUTB_MOTB_1","S>>NIL_TUTB_TUTB_1","S>>NIL_TWPA_BWMP","S>>NIL_TWPA_TPRS","S>>NIL_TWPA_WEMW4","S>>V_NIL_DVBG_STBG","S>>V_NIL_NIL_HUWT","S>>V_NIL_NIL_MNWT","S>>V_NIL_NIL_MW1NWB","S>>V_NIL_NIL_RBMW3","S>>V_NIL_NIL_RBNW1","S>>V_NIL_RBTX_WEMW4","S>>V_NIL_WTTP_WEMW4","S>HUWT_BGTX_RHBR-T","S>HUWT_BWPA_RHBR-T","S>HUWT_NIL_STBG-T","S>NIL_ACPA_MAMO","S>NIL_BRTW_MNWT","S>NIL_BWMP_CNRB","S>NIL_BWMP_HUWT","S>NIL_BWMP_RHBR-T","S>NIL_DVBG_BRTW","S>NIL_DVTX_DVTX","S>NIL_HUWT_STBG","S>NIL_LKDV_CNRB","S>NIL_MHNW1_MHNW2","S>NIL_NIL_DLAW","S>NIL_NIL_MHNW2","S>NIL_NIL_MYSG-T","S>NIL_NIL_NWMH2","S>NIL_NIL_SETX12","S>NIL_NIL_SGBN","S>NIL_NIL_SGMYSE-T2","S>NIL_NIL_STST-T","S>NIL_NWMH1_NWMH2","S>NIL_NWRB1_MWP3RB","S>NIL_NWRB2_NWRB1","S>NIL_RBMWP3_RBNW1","S>NIL_SGBN_SGSE-T","S>NIL_SGBN_SGSE-T2","S>NIL_TINO3_TINO4","S>NIL_WEMW4_WTTP","S>NIL_WERB_WEWT","S>V_NIL_SEHY","S>V_NIL_SETX_SETX","S>V_NIL_SETX_SETX1","SVML^NIL_MH-CAP_ON","SVML_233","SVML_RAT_LIM_DYN","SVML_ZERO","SV_HEY_600_TEST","S^BUNGAMB1_150","S^CGBESS01_40","S^CMWF_39","S^NIL_SA_NORTH","S^SNWWF_60","S^WPWF_60","S_NIL_STRENGTH_1","S_V_HEYWOOD_OFGS","S_V_NIL_ROCOF","S_WDR_NO_SCADA","T::T_NIL_1","T::T_NIL_3","T>>T_NIL_BL_EXP_3F","T>>T_NIL_BL_EXP_3G","T>>T_NIL_BL_EXP_3H","T>>T_NIL_BL_EXP_4E","T>>T_NIL_BL_EXP_4F","T>>T_NIL_BL_EXP_5F","T>>T_NIL_BL_EXP_5G","T>>T_NIL_BL_EXP_5H","T>>T_NIL_BL_EXP_6E","T>>T_NIL_BL_EXP_6F","T>>T_NIL_BL_EXP_7C","T>T_NIL_110_1","T>T_NIL_110_2","T>T_NIL_110_4","T>T_NIL_110_5","T>T_NIL_BL_110_2","T>T_NIL_BL_110_25","T>T_NIL_BL_110_3","T>T_NIL_BL_110_4","T>T_NIL_BL_110_5","T>T_NIL_BL_110_8_1","T>T_NIL_BL_110_9","T>T_NIL_BL_220_6B","T>T_NIL_BL_220_6C","T>T_NIL_BL_220_6D","T>T_NIL_BL_3A","T>T_NIL_BL_3B","T>T_NIL_BL_3C","T>T_NIL_BL_3D","T>T_NIL_BL_3E","T>T_NIL_BL_4A","T>T_NIL_BL_4B","T>T_NIL_BL_4C","T>T_NIL_BL_4D","T>T_NIL_BL_5A","T>T_NIL_BL_5B","T>T_NIL_BL_5C","T>T_NIL_BL_5D","T>T_NIL_BL_5E","T>T_NIL_BL_6A","T>T_NIL_BL_6B","T>T_NIL_BL_6C","T>T_NIL_BL_6D","T>T_NIL_BL_IMP_1B","T>T_NIL_BL_IMP_2B","T>T_NIL_BL_IMP_3F","T>T_NIL_BL_IMP_3FF","T>T_NIL_BL_IMP_3G","T>T_NIL_BL_IMP_3H","T>T_NIL_BL_IMP_4E","T>T_NIL_BL_IMP_4EE","T>T_NIL_BL_IMP_4F","T>T_NIL_BL_IMP_5F","T>T_NIL_BL_IMP_5FF","T>T_NIL_BL_IMP_5G","T>T_NIL_BL_IMP_5H","T>T_NIL_BL_IMP_6E","T>T_NIL_BL_IMP_6EE","T>T_NIL_BL_IMP_6F","T>T_NIL_BL_IMP_7C","T>T_NIL_BL_IMP_7CC","T>T_NIL_BL_IMP_8B","T>T_NIL_BL_IMP_8C","T>T_NIL_NCSPS5_1B","T>T_NIL_NCSPS5_3F","T>T_NIL_NCSPS5_3FF","T>T_NIL_NCSPS5_3G","T>T_NIL_NCSPS5_3H","T>T_NIL_NCSPS5_7C","T>T_NIL_TOV_5F","T>T_NIL_TOV_5FF","TVBL_NIL_CONT_459","TVBL_NIL_DYN","T^T_NIL_BL_1","T^T_NIL_BL_2","T^T_NIL_BL_4","T^T_NIL_BL_5","T^T_NIL_BL_6","T^T_NIL_BL_7","T^V_NIL_10","T^V_NIL_11","T^V_NIL_8","T^V_NIL_9","T^V_NIL_BL_6","T_MRWF_GCS","T_MRWF_QLIM_1","T_MRWF_QLIM_1A","T_MRWF_QLIM_1B","T_MRWF_QLIM_2","T_MRWF_QLIM_3","T_MRWF_QLIM_4","T_MRWF_QLIM_5","T_MRWF_QLIM_6","T_MRWF_QLIM_7","T_ROCOF_1","T_ROCOF_2","T_ROCOF_3_1","T_ROCOF_3_2","T_ROCOF_3_3","T_TAMARCCGT_GCS","T_V_NIL_FCSPS","V::N_NIL_O1","V::N_NIL_O2","V::N_NIL_V1","V::N_NIL_V2","V::S_NIL_MAXG_1","V::S_NIL_TBSE_1","V::V_1900","V:SS_920","V:SS_970_HY_TEST","V:S_700","V:S_750_HY_TEST","V:T_NIL_BL_1","V>>BELML_BAML1_BAML2","V>>DBL_MSDD_MSDD","V>>DBL_MSDD_MSDD_SIP","V>>DBT_DDTX1_DDTX","V>>DBT_DDTX2_DDTX","V>>DBT_DDTX3_DDTX","V>>DDTX1_3_DDTX2_NIL","V>>DDTX2_3_DDTX1_NIL","V>>DDTX3_DDT1_DD2_LH","V>>DDTX3_DDT2_DD1_LH","V>>DDTX3_DDTX1_DDTX2","V>>DDTX3_DDTX2_DDTX1","V>>DDTX_DDTX1_NIL_LH","V>>DDTX_DDTX2_NIL_LH","V>>NIL_ARTSTL_ARCW","V>>NIL_ARWB_KGBE","V>>NIL_ARWB_RCWEKG","V>>NIL_BABE_HOMRKM","V>>NIL_BABE_KMRC","V>>NIL_BABE_KMRC_1","V>>NIL_BABE_RCWEKO","V>>NIL_BABE_SHBE","V>>NIL_BABE_SHBE_5M","V>>NIL_BANBGR_ARCW","V>>NIL_BEBA_ARWBBA","V>>NIL_BEKG_HOMRKM","V>>NIL_BGRART_ARCW","V>>NIL_CWAR_KGBE","V>>NIL_DDSM_DDSM","V>>NIL_DDSM_DDSM_SIP","V>>NIL_DDTX1_NIL","V>>NIL_DDTX2_NIL","V>>NIL_DDTX3_NIL","V>>NIL_ELML_BAML2","V>>NIL_EPTT_DDSM_SIP","V>>NIL_HYSE_HYSE","V>>NIL_KGWE_HOMRKM","V>>NIL_MBDD_MBDD","V>>NIL_MLGT_MLGT","V>>NIL_MLSY_MLSY","V>>NIL_MSDD1_MSDD2","V>>NIL_MSDD1_MSDD2_S","V>>NIL_MSDD2_MSDD1","V>>NIL_MSDD2_MSDD1_S","V>>NIL_RCWE_BUBD","V>>NIL_RCWE_HOBUCW","V>>NIL_RCWE_HOMRKM","V>>NIL_SMDD_SMDD","V>>NIL_SMTX_SMTX_R2","V>>NIL_SMTX_SMTX_R5","V>>NIL_WBBA_KGBE","V>>NIL_WBBA_RCWEKG","V>>NIL_WEKG_HOBUCW","V>>NIL_WEKG_HOMRKM","V>>NIL_WERC_HOMRKM","V>>NSWRB_BEKG_X3","V>>NSWRB_BEKG_X5","V>>NSWRB_KGWE_X3","V>>NSWRB_KGWE_X5","V>>NSWRB_WERC_X3","V>>NSWRB_WERC_X5","V>>N_NIL_65","V>>N_NIL_65_051","V>>N_NIL_65_66","V>>N_NIL_66","V>>N_NIL_66_051","V>>N_NIL_66_65","V>>S_NIL_DVBG_DVBR","V>NIL_GNTX_GNTX","V>NIL_GNTX_GNTX_TEMP","V>NIL_MRTX1_NIL","V>NIL_MRTX2_NIL","V>NIL_TGTX_NIL","V>NIL_TGTX_TGTX_1","V>NIL_TGTX_TGTX_2","V>NIL_TGTX_TGTX_20S","V>NIL_WBBA_CWBUHO","V>NIL_WBBA_HOMRKM","V>NIL_WBBA_KMRC","V>NIL_WBBA_KMRC_1","V>NIL_WETX_NIL","V>NIL_YPRO7_YPHW1","V>NIL_YPRO7_YPRO8","V>S_NIL_SETX_SETX"],"is_categorical":true},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"DUID to which the Constraint is confidential. Null denotes non-confidential","examples":["ASTHYD1","BBATTERY1","BLOWERNG","BODWF1","BRAEMAR1","BRDDBES1","BRDDSF01","BUNGAMB1","BUSF1","CGBESS01","CLARESF1","CLEMGPWF","CLRKCWF1","CLRKCWF2","COHUNSF1","CRWASF1","CSPVPS1","DAYDSF1","DRVIOT05","DRVIOT06","EMERASF1","ERB02","FINLYSF1","GORDON","GREENB1","HAMISF1","HAUGHT11","HAYMSF1","JUNEESF1","KABANWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KSP1","LANCSF1","LGAPBS1","LIMOSF11","LK_ECHO","LNGS2","MCINTYR1","METZSF1","MEWF1","MOREESF1","MOUSF1","MRNBESS1","MTGELWF1","MUCRKSF1","MULWASF1","MUSSELR1","MUWAWF1","MUWAWF2","OAKLAND1","PLBESS1","PPCCGT","PUMP1","RANGEB1","RRSF1","RUGBYR1","SMCSF1","SMFBESS1","SMFBESS2","SNB01","SNB02","SNOWTWN1","STABESS1","SWANBBF1","TVCC201","W/HOE#1","WAMBOWF1","WAMBOWF2","WANDSF1","WANDSF2","WATERLWF","WDBESS1","WDBESS2","WHITSF1","WILLBES1","WOOLES1","WPWF","WTAHB1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"name_in_csv":"CONFIDENTIAL_TO","is_categorical":true},"GENCONID_EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Effective date of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["2012/07/04 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID_VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Version number of the Generic Constraint (ConstraintID). This field is used to track the version of this generic constraint applied in this dispatch interval","examples":["1","2"],"is_integer":true,"num_int_bits":128},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHCONSTRAINT."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregation of the constraints LHS term solution values","examples":["-1.19891","1.95052","0","1087"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal value of violated constraint","examples":["-4.42378","0.01","0","23202.58808"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique period identifier, in the format yyyymmddpp. The period (pp) is 01 to 48, with 01 corresponding to the half-hour ending at 04:30am.","examples":["2026090101"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101"],"unsigned_int":true,"num_int_bits":32},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"RHS value used.","examples":["-15.00029","0.0001","0","34264"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"SPD Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Degree of constraint violation","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"max_files_per_month":2,"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":26460616,"decompressed_size_all_time":31724686230},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes"},"PREDISPATCHINTERCONNECTORRES":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"INTERCONNECTOR_SOLN","VERSION":3}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#68"],"comment":"PREDISPATCHINTERCONNECTORRES records Interconnector flows and losses for the periods calculated in each predispatch run. Only binding and interconnector constraints are reported.\nSome fields are for the Frequency Controlled Ancillary Services export and import limits and extra reporting of the generic constraint setting the energy import and export limits.","description":"Source\n\nPREDISPATCHINTERCONNECTORRES updates with every thirty-minute\npredispatch run.\n\nNote\n\nMW losses can be negative depending on the flow.\n\nThe definition of direction of flow for an interconnector is that\npositive flow starts from the FROMREGION in INTERCONNECTOR.","primary_keys":["DATETIME","INTERCONNECTORID"],"indexes":[["PREDISPATCHSEQNO"],["LASTCHANGED"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"EXPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the export limit","examples":["I_6F_NS_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_33_34","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","NRM_VIC1_SA1","N^^N_NIL_WGLT","S>>NIL_RBTU_WEWT","S>>NIL_TWPA_TPRS","S>NIL_MHNW1_MHNW2","T^V_NIL_9","T^V_NIL_BL_6","T_V_NIL_FCSPS","V::N_HWRO3_O2","V::N_HWRO3_V2","V::N_HWSM_V2","V::N_NIL_V2","V>>NIL_SMTX_SMTX_R5","V>>SMF1_SMF2_NIL_R5","VSML_-020","VSML_050","VSML_ZERO","VS_HEY_600_TEST","V^^N_CNCW_1","V^^N_NIL_1","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"]},"EXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit.","examples":["-0.00001","4.37233","0","950"],"is_float":true},"FCASEXPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated export limit applying to energy + FCAS.","examples":["-0.00001","64.80056","0","2399"],"is_float":true},"FCASIMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit applying to energy + FCAS.","examples":["-20.78175","0.00001","0","50"],"is_float":true},"IMPORTGENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Generic Constraint setting the import limit","examples":["CA_SYDS_59A889E5_1","F_MAIN++APD_TL_L5","F_MAIN++LREG_0210","F_Q++NIL_R5","F_Q++NIL_R6","F_Q++NIL_R60","F_T++NIL_CHWF_TG_R6","F_T++NIL_MG_R6","F_T++NIL_MRWF_TG_R6","F_T++NIL_WF_TG_R60","I_6F_NS_150","I_6F_SN_150","N>>NIL_060_051","N>>NIL_85_86_S","N>>NIL_86_85_S","N>>NIL_964_84_S","N>>NIL_966/1_87_S","N^^N_NIL_WGLT","N^^V_CNCW_1","N^^V_MLNK_1","N^^V_MLNK_ARWBBA","N^^V_NIL_ARWBBA","N_NIL_TE_B","Q>NIL_757_758_ECS","Q^^N_NIL_SRAR","S:VS_800","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","SVML_-020","SVML_050","SVML_ZERO","S_V_HEYWOOD_OFGS","T::T_NIL_3","T::T_PMWA_110_2","T>>T_NIL_BL_EXP_4F","T>>T_NIL_BL_EXP_7C","T_ROCOF_3_3","V::N_HWRO3_V2","V::N_HWSM_V2","V::N_NIL_V2","V:T_NIL_BL_1","V>>BELMLCB_BAML_TGML","V>>BELML_BAML1_BAML2","V>>NIL_MLGT_MLGT","V>>NIL_SMTX_SMTX_R5","V>>SMF1_SMF2_NIL_R5","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V_T_NIL_FCSPS"]},"IMPORTLIMIT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated import limit.","examples":["-8.13072","0.00001","0","50"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHINTERCONNECTORRES."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed.","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT_EXPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Export (Factor >= 0)","examples":["-0.22","0","-3","-8352000"],"is_float":true},"LOCAL_PRICE_ADJUSTMENT_IMPORT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this Interconnector: Sum(MarginalValue x Factor) for all relevant Constraints, for Import (Factor >= 0)","examples":["0.11","0","6","8352940"],"is_float":true},"LOCALLY_CONSTRAINED_EXPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Export: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"LOCALLY_CONSTRAINED_IMPORT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment_Import: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["0","1","2"],"is_integer":true,"num_int_bits":8},"MARGINALLOSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor. Use this to adjust bids between reports.","examples":["0.46117","1.59769"],"is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"$ Marginal value of interconnector constraint from SPD","examples":["0"],"is_float":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Metered MW Flow from EMS. For periods subsequent to the first period of a Pre-Dispatch run, this value represents the cleared target for the previous period of that Pre-Dispatch run.","examples":["-0.1","0.1","0","326"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated MW Flow","examples":["-6.34144","4.37233","0","547"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated MW Losses","examples":["-0.01251","0.01466","0","120.57315"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["01"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090423"],"unsigned_int":true,"num_int_bits":32},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"SPD Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Degree of violation of interconnector constraint in MW","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHINTERCONNECTORRES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":327277,"decompressed_size_all_time":414139600},"visibility":"Public","trigger":"Every thirty-minute pre-dispatch run"},"PREDISPATCHINTERSENSITIVITIES":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"INTERCONNECTR_SENS","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#79","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46_1.htm"],"comment":"PREDISPATCHINTERSENSITIVITIES sets out the sensitivity flows for each interconnector by period.","primary_keys":["DATETIME","INTERCONNECTORID"],"indexes":[["LASTCHANGED"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2024/07/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHINTERSENSITIVITIES."],"is_boolean":true},"INTERVENTION_ACTIVE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes","examples":["0"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2024/07/01 00:05:05"],"parse_csv_as_string":true,"is_s_datetime":true},"MWFLOW1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 1","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 2","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 3","examples":["-0.68","1.19","0","661"],"is_float":true},"MWFLOW4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 4","examples":["-0.16","0.06","0","600"],"is_float":true},"MWFLOW5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 5","examples":["-0.45","1.19","0","661"],"is_float":true},"MWFLOW6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 6","examples":["-0.30","0.23","0","600"],"is_float":true},"MWFLOW7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 7","examples":["-0.45","0.23","0","661"],"is_float":true},"MWFLOW8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 8","examples":["-0.68","0.71","0","520"],"is_float":true},"MWFLOW9":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 9","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW10":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 10","examples":["-0.68","1.90","0","500"],"is_float":true},"MWFLOW11":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 11","examples":["-0.68","3.17","0","600"],"is_float":true},"MWFLOW12":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 12","examples":["-0.45","0.08","0","247"],"is_float":true},"MWFLOW13":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 13","examples":["-1.36","1.39","0","600"],"is_float":true},"MWFLOW14":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 14","examples":["-1.69","1.83","0","335"],"is_float":true},"MWFLOW15":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 15","examples":["-0.68","4.31","0","600"],"is_float":true},"MWFLOW16":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 16","examples":["-0.68","0.84","0","600"],"is_float":true},"MWFLOW17":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 17","examples":["-0.68","0.39","0","600"],"is_float":true},"MWFLOW18":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 18","examples":["-0.68","5.34","0","520"],"is_float":true},"MWFLOW19":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 19","examples":["-0.68","0.87","0","600"],"is_float":true},"MWFLOW20":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 20","examples":["-0.68","0.03","0","520"],"is_float":true},"MWFLOW21":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 21","examples":["0"],"is_float":true},"MWFLOW22":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 22","examples":["0"],"is_float":true},"MWFLOW23":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 23","examples":["0"],"is_float":true},"MWFLOW24":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 24","examples":["0"],"is_float":true},"MWFLOW25":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 25","examples":["-0.68","1.17","0","614"],"is_float":true},"MWFLOW26":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 26","examples":["-0.68","4.25","0","600"],"is_float":true},"MWFLOW27":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 27","examples":["-0.37","0.07","0","661"],"is_float":true},"MWFLOW28":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 28","examples":["-2.46","1.31","0","600"],"is_float":true},"MWFLOW29":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 29","examples":["-0.20","1.19","0","600"],"is_float":true},"MWFLOW30":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 30","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW31":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 31","examples":["-0.68","1.19","0","661"],"is_float":true},"MWFLOW32":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 32","examples":["-0.68","2.20","0","600"],"is_float":true},"MWFLOW33":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 33","examples":["-0.45","1.19","0","661"],"is_float":true},"MWFLOW34":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 34","examples":["-0.23","3.17","0","600"],"is_float":true},"MWFLOW35":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 35","examples":["-0.55","0.18","0","567"],"is_float":true},"MWFLOW36":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 36","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW37":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 37","examples":["-0.11","1.19","0","600"],"is_float":true},"MWFLOW38":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 38","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW39":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 39","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW40":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 40","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW41":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 41","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW42":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 42","examples":["-0.68","1.19","0","600"],"is_float":true},"MWFLOW43":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW flow for given Interconnector for scenario 43","examples":["-0.68","0.08","0","600"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["1"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2024063041","2024070601"],"unsigned_int":true,"num_int_bits":32},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"LP Solver Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_PREDISPATCHINTERCONNECTR_SENS_D_202407010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":7},"compressed_size_per_month":529060,"decompressed_size_all_time":666317570},"visibility":"Public","trigger":"Every 5 minutes","pagination":["Elec46_1.htm"]},"PREDISPATCHLOAD":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":4},{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":5}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec47.htm#87","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec47_1.htm"],"comment":"PREDISPATCHLOAD shows pre-dispatch targets for each dispatchable unit, including additional fields to handle the Ancillary Services functionality. No record is written where a unit is not dispatched. PREDISPATCHLOAD shows all the results for each period.","description":"Source\n\nOwn (confidential) data updates every thirty minutes, with whole market\ndata for the day before available as part of next day market data.\n\nNote\n\n\\*\\* A flag exists for each ancillary service type such that a unit\ntrapped or stranded in one or more service type can be immediately\nidentified. The flag is defined using the low 3 bits as follows:\n\n| Flag Name | Bit | Description                                                                                                                                                                                                     |\n|-----------|-----|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|\n| Enabled   | 0   | The unit is enabled to provide this ancillary service type.                                                                                                                                                     |\n| Trapped   | 1   | The unit is enabled to provide this ancillary service type, however the profile for this service type is causing the unit to be trapped in the energy market.                                                   |\n| Stranded  | 2   | The unit is bid available to provide this ancillary service type, however, the unit is operating in the energy market outside of the profile for this service type and is stranded from providing this service. |\n\nInterpretation of the bit-flags as a number gives the following\npossibilities (i.e. other combinations are not possible):\n\n| Numeric Value | Bit (2,1,0) | Meaning                                 |\n|---------------|-------------|-----------------------------------------|\n| 0             | 000         | Not stranded, not trapped, not enabled. |\n| 1             | 001         | Not stranded, not trapped, is enabled.  |\n| 3             | 011         | Not stranded, is trapped, is enabled.   |\n| 4             | 100         | Is stranded, not trapped, not enabled.  |\n\nFor example, testing for availability can be done by checking for odd\n(=available) or even (=unavailable) number (e.g. mod(flag,2) results in\n0 for unavailable and 1 for available).\n\n\\*\\*\\* \"Actual FCAS availability\" is determined in a post-processing\nstep based on the energy target (TotalCleared) and bid FCAS trapezium\nfor that interval. However, if the unit is outside the bid FCAS\ntrapezium at the start of the interval (InitialMW), the \"Actual FCAS\navailability\" is set to zero. For regulation services, the trapezium is\nthe most restrictive of the bid/SCADA trapezium values.","primary_keys":["DATETIME","DUID"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"],["PREDISPATCHSEQNO"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier for fast start","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD01","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNAES1","ASNBRL1","ASNENC1","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSENC1","ASSERDV1","ASTHYD1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DPNTB1","DRACAN1","DRACAV1","DRAESN3","DRAESS1","DRBRLV01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DRHTVP03","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRVIOT07","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LDBESS1","LEM_WIL","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY1","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MARYRSF1","MBPS2PV1","MCINTYR1","MCKAY1","MEADOWBK","MERCER01","METZSF1","MEWF1","MIDDLSF1","MINTARO","MLB01","MOKOSF1","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPP_1","MPP_2","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUSSELR1","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NESBESS1","NESBESS2","NEVERSF1","NEWENSF1","NEWENSF2","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","ORABESS1","OSB-AG","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QBYNB1","QPS1","QPS2","QPS3","QPS4","QPS5","QPSFB1","QPSFB2","RANGEB1","REECE1","REECE2","RESS1","RIVNB2","ROMA_7","ROMA_8","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUGBYR1","RYANCWF1","RYEPARK1","SALTCRK1","SAPHWF1","SEBSF1","SHGEN","SHPUMP","SITHE01","SMCSF1","SMFBESS1","SMFBESS2","SMTHBES1","SNAPPER1","SNB01","SNB02","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYGJP","SNOWYP","SNUG1","SRSF1","STABESS1","STAN-1","STAN-2","STAN-3","STAN-4","STARHLWF","STOCKYD1","STUBSF1","STUBSF2","STWF1","SUNRSF1","SUNTPSF1","SWANBBF1","SWAN_E","TALWA1","TALWB1","TARALGA1","TARBESS1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TB2B1","TB2SF1","TBSF1","TEMPB1","TIB1","TNPS1","TORRB2","TORRB3","TORRB4","TREVALLN","TRGBESS1","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","ULPBESS1","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VENUS1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VSNEL2S1","VSQHT1V1","VSSAE1V1","VSSSE1V1","VSSSH1S1","VSVEL2S1","W/HOE#1","W/HOE#2","WAGGNSF1","WALGRV1","WAMBOWF1","WAMBOWF2","WANDB1","WANDSF1","WANDSF2","WARWSF1","WARWSF2","WATERLWF","WDBESS1","WDBESS2","WDGPH1","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WILLBES1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WOLARSF1","WOODLWN1","WOOLES1","WOOLGSF1","WPWF","WRSF1","WRWF1","WSTWYSF1","WTAHB1","WUNUSF1","WYASF1","YABULU","YABULU2","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"AGCSTATUS":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"AGC Status from EMS","examples":["0","1"],"is_integer":true,"num_int_bits":8},"AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Scheduled units, this is the MAXAVAIL bid availability For Semi-scheduled units, this is the lower of MAXAVAIL bid availability and UIGF","examples":["3.103","0","1","1475"],"is_float":true},"CONFORMANCE_MODE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Mode specific to units within an aggregate. 0 - no monitoring, 1 - aggregate monitoring, 2 - individual monitoring due to constraint","examples":["0","1"],"is_integer":true,"num_int_bits":32},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier","examples":["AKWB1W","NAL11C","NAL12M","NASACA01","NASAGL03","NASENG01","NASGRD01","NASGRU01","NASHYD01","NASSHU01","NASSHU02","NASVTA01","NASYES01","NBA21B","NBAY1","NBAY2","NBAY3","NBAY4","NBB21B","NBES1B","NBK11B","NBKB3B","NBKW1S","NBL21L","NBLW8","NBOD1B","NBSF1L","NBSF2S","NCDS1C","NCKW1C","NCLG1D","NCLG2D","NCLG3D","NCLG4D","NCLS1C","NCLW1C","NCMA3B","NCRN1C","NCW31C","NCWF2W","NDNH1H","NDNS1D","NDNSG","NDT13T","NDTB1T","NEPS1","NEPS2","NEPS3","NEPS4","NER21E","NERB1E","NFBS1J","NFNS1F","NGJP","NGNE1G","NGUR1G","NGUR2G","NGUR3G","NGUT8","NHLB1S","NHUM","NJDA1G","NLDB1L","NLMB1L","NLTS3","NLTS8","NMLS1M","NMOS1M","NMR22T","NMR41M","NMTP1","NMTP2","NMTZ1M","NMUR8","NMWB1W","NNCP1H","NNCP2H","NNEE1H","NNRN1A","NONF1F","NPG11P","NPG12G","NPKQ1Q","NPKQ2Q","NQBB3Q","NQBC3C","NRB23R","NRBB3R","NRDP3D","NRPK1R","NRT1","NRTAMAL1","NRTBORA1","NRTENOC1","NRTNEM02","NRTNEM03","NRTNEM04","NRTNEM05","NRTNEM06","NSAP1S","NSHL","NSHP1","NSTB1S","NSTU1S","NSWB3W","NSYW1","NURB1N","NURB2N","NURQ1U","NURQ2U","NURQ3U","NURQ4U","NURR1N","NURR2N","NUTS8","NVPEVER1","NVPP5","NVPP6","NWDENC01","NWDENC03","NWDENC04","NWDENC05","NWDENC06","NWDENC07","NWDENC09","NWDENC10","NWDENC11","NWDENC12","NWDENC13","NWDENC14","NWDENC16","NWDENC17","NWDENC19","NWDENC20","NWDVTA01","NWGG1W","NWGJ1J","NWGJ2S","NWGJ3W","NWGJ4W","NWGS1B","NWL21W","NWL82N","NWLA1W","NWLN1W","NWLO1O","NWLS3N","NWLS4W","NWLW1S","NWOW1W","NWRK1W","NWRK2W","NYS12A","QAFH1K","QAFH2K","QAFH3K","QAFH4K","QASDAL01","QASEEQ01","QASEQL01","QASPWR01","QASVTA01","QBCB3B","QBCG","QBCK1","QBCK2","QBDR1L","QBGH1","QBGH2","QBKB1S","QBLG1G","QBRA1","QBRA2","QBRA3","QBRA4K","QBRA5B","QBRA6B","QBRA7B","QBRA8D","QBRS1D","QBSS1B","QBSS2B","QBSW1C","QBSW2C","QCAB1","QCAB2","QCAC3","QCAC4","QCBF1D","QCBR1C","QCBS1B","QCCK1D","QCCK2H","QCLA1C","QCND1C","QCOS1C","QCPG1C","QDMR1W","QDMW1W","QDNSG","QGAR1","QGBB1G","QGLD1","QGLD2","QGLD3","QGLD4","QGLD5","QGLD6","QGNS1B","QHAR1H","QKAH1","QKAH2","QKAH3","QKAH4","QLCS1A","QLIS1E","QLIS2M","QLLV3C","QMPL1R","QMRR1M","QMRY1Y","QMRY2M","QMRY3W","QMRY4W","QMSP1","QMSP2","QMSP3M","QMSW1M","QOKY1","QOKY2","QORS1E","QRMA7","QRMA8","QROG1K","QROG3R","QROW1K","QROW2K","QROW3K","QROW4K","QRT1","QRTENOC1","QSLD1H","QSLS1W","QSPB1B","QSPS1S","QSPT1S","QSTB1S","QSTN1","QSTN2","QSTN3","QSTN4","QSWE","QTBS1C","QTBS2S","QTKS1O","QTKS2O","QTMW1K","QTNT","QTRB1T","QTRN1","QTRN2","QTRN3","QTRN4","QTRS1K","QTYP","QTZS1S","QVPHYDR1","QWDB3C","QWDE3W","QWDE4W","QWDENC02","QWDENC04","QWDR1W","QWDS1U","QWIP1","QWIP2","QWIV1","QWIV2","QWKM1M","QWLB1W","QWLM1M","QWLS1W","QWSB3W","QWSR1W","QWSR2W","QWSS1G","QYAG1R","SART2","SART3","SART4","SART5","SART6","SASAGL01","SASDSC01","SASENGY1","SASEQL01","SASGRD01","SASHYD01","SASPAP01","SASSHU01","SASSHU02","SASVTA01","SASYES01","SASYES02","SASYES03","SASYES04","SBEL1A","SBEL2P","SBEM1B","SBEM2B","SBLWS1","SBLWS2","SBPS1B","SBUA1B","SBYW1B","SCGB1C","SCGW1P","SCRK","SDAN3D","SDAP1P","SDAP2P","SDCA1","SDCA2","SDCA3","SDNSG","SDRN1","SHDW1H","SHDW2H","SHDW3H","SHPS1","SHPS2W","SHVA3H","SHVA4H","SLBB3L","SLGW1L","SLGW4L","SLGW5L","SMA21M","SMA31M","SMAB1M","SMAE1M","SMAY1","SMAY2","SMAY3W","SMH21M","SMOK1H","SMPS","SMTL3H","SMTM1","SMVE1","SMVE14","SMVE15","SMVE2","SMVE3P","SMVE6D","SMW11M","SMW21M","SMW31M","SMW41M","SNBN1","SNPT1S","SNWF1T","SPEW1","SPEW2","SPGG1B","SPGW2B","SPGW6B","SPL31P","SPLN1","SPPT","SQPS1","SQPS2","SQPS3","SQPS4","SQPS5Q","SRAB1G","SROB1G","SRT1","SRTAGLE1","SRTENOC1","SSGA1","SSNN1","SSYP1","STBB1T","STBB4T","STBS1T","STET1T","STPB3T","STSB2","STSB3","STSB4","SUMM1S","SUNN1S","SVPSHUB1","SWDENC02","SWDVTA01","SWGL1W","SWLE","TASFRM01","TASFRM02","TASVTA01","TBB11","TBB12","TBB13","TBB14A","TCE11","TDE11M","TDG11","TDNSG","TFA11","TFI11","TGH11G","TGO11","TJB11","TLE11","TLI11","TMA11","TMB11","TPM11","TPM21","TRCA1","TRCB1","TRT1","TRTHYDR1","TSH11","TTA11","TTI11","TTR11","TTU11","TTV11A","TWC11C","VAPD1","VART1A","VASACA01","VASACL01","VASBRA01","VASDAM01","VASENG01","VASEQL01","VASGRD01","VASGRD02","VASPBL01","VASPWR01","VASPWR02","VASSER01","VASVTA01","VAT21L","VAT22L","VBA23B","VBAW1Y","VBBT1B","VBBT2B","VBGT1B","VBGT4B","VCB33R","VCPT1C","VCWL1C","VDNSG","VDPS","VELT1M","VELT2M","VELT3E","VEPS1","VEPS2","VGET1G","VGN21G","VGN61M","VGNS1G","VGNS2W","VGP21G","VGP22G","VGPT1G","VGPT2G","VGPT3G","VGTW1M","VHGT1S","VHOG1K","VHUM","VHW23H","VICRT10","VICRT11","VICRT12","VICRT2","VICRT3","VICRT4","VICRT5","VICRT6","VICRT7","VICRT8","VICRT9","VJLGA1","VJLGA2","VJLGA3","VJLGA4","VJLGB1","VJLGB2","VJLGB3","VKGB3G","VKGP1K","VKGS1G","VKGS2C","VKMT1K","VKOT1K","VLYP010","VLYP011","VLYP012","VLYP07","VLYP08","VLYP09","VLYP1","VLYP2","VLYP3","VLYP4","VLYP5","VLYP6","VM041M","VM051D","VM052D","VM053D","VM0P1O","VM0P2O","VMKP1","VMLB3V","VMRT1M","VMRT2M","VMW61L","VMWT12","VMWT2","VMWT3","VMWT9B","VNPS","VPLT1P","VPR21M","VPR31M","VPRT1M","VRCS1K","VRCS2Y","VRT1","VRTENOC1","VSHS1N","VSHS2G","VSHS2W","VSHS3L","VSM71C","VTB21M","VTG21M","VTG31T","VTG61S","VTGT3A","VTR11H","VTR31R","VTRT1M","VTTS1","VVPEVER1","VWDENC01","VWDENC02","VWDENC03","VWDENC05","VWDENC06","VWDENC08","VWDENC09","VWES1B","VWES2W","VWKP1","VYP21","VYP22","VYP23","VYP24"],"is_categorical":true},"DISPATCHMODE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Dispatch mode of unit for fast start (1-4)","examples":["0"],"is_integer":true,"num_int_bits":8},"ELEMENT_CAP":{"sql_type":"NUMBER(5,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Cap on the number of turbines or inverters at a DUID.","is_integer":true,"num_int_bits":32},"ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The projected energy storage based on cleared energy and regulation FCAS dispatch(MWh)","examples":["0.01265","0","496.89452"],"is_float":true},"ENERGY_STORAGE_MAX":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only - Maximum Energy Storage constraint limit (MWh)","is_float":true},"ENERGY_STORAGE_MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only - Minimum Energy Storage constraint limit (MWh)","is_float":true},"INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The energy storage at the start of this dispatch interval(MWh)","is_float":true},"INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial MW at start of first period. For periods subsequent to the first period of a Pre-Dispatch run, this value represents the cleared target for the previous period of that Pre-Dispatch run. Negative values when Bi-directional Unit start from importing power, otherwise positive.","examples":["-0.008","0.00001","0","405"],"warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHLOAD."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Lower1Sec - TraderSolution element L1Target attribute","examples":["5.30709","0","27","35"],"is_float":true},"LOWER1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Lower 1Sec Availability","examples":["0","1","225"],"is_float":true},"LOWER1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element L1Flags attribute","examples":["0","1"],"is_boolean":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min MW target in period","examples":["4.42822","0","2","80"],"is_float":true},"LOWER5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 5min availability","examples":["2.025974","0","1","236"],"is_float":true},"LOWER5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 5min status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec MW target in period","examples":["46.66455","0","2","80"],"is_float":true},"LOWER6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 6sec availability","examples":["3.333333","0","1","225"],"is_float":true},"LOWER6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 6sec status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec MW target in period","examples":["30.91022","0","2","114"],"is_float":true},"LOWER60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 60sec availability","examples":["3.591837","0","1","236"],"is_float":true},"LOWER60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower 60sec status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation reserve target","examples":["0","4","64"],"is_float":true},"LOWERREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower reg availability","examples":["59.99988","0","2","415"],"is_float":true},"LOWERREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Lower Reg status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"MARGINAL5MINVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 5 min from LP Solver","is_float":true},"MARGINAL6SECVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 6 seconds from LP Solver","is_float":true},"MARGINAL60SECVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for 60 seconds from LP Solver","is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal $ value for energy from LP Solver","is_float":true},"MIN_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"BDU only. Load side availability (BidOfferPeriod.MAXAVAIL where DIRECTION = LOAD)","examples":["0","2","415"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["01"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090102"],"unsigned_int":true,"num_int_bits":32},"RAISE1SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatched Raise1Sec - TraderSolution element R1Target attribute","examples":["69.52352","0","1","80"],"is_float":true},"RAISE1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Raise 1Sec Availability","examples":["8.739724","0","1","225"],"is_float":true},"RAISE1SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"TraderSolution element R1Flags attribute","examples":["0","1"],"is_boolean":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min MW target in period","examples":["84.40087","0","1","80"],"is_float":true},"RAISE5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 5min availability","examples":["20.7","0","1","450"],"is_float":true},"RAISE5MINFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Raise 5min status flag","examples":["0","1"],"is_boolean":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec MW target in period","examples":["1.12106","0","1","80"],"is_float":true},"RAISE6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 6sec availability","examples":["7.425","0","1","450"],"is_float":true},"RAISE6SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Raise 6sec status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec MW target in period","examples":["35.65183","0","1","80"],"is_float":true},"RAISE60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 60sec availability","examples":["27.5","0","1","450"],"is_float":true},"RAISE60SECFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Raise 60sec status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation reserve target","examples":["0","3","42"],"is_float":true},"RAISEREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise reg availability","examples":["13.18253","0","2","255"],"is_float":true},"RAISEREGFLAGS":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Raise reg status flag","examples":["0","1","4"],"is_integer":true,"num_int_bits":16},"RAMPDOWNRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp down rate in period in MW/minute","examples":["0","60","20400"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Ramp up rate in period in MW/minute","examples":["0","60","20400"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"SPD Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SEMIDISPATCHCAP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Boolean representation flagging if the Target is Capped","examples":["0","1"],"is_boolean":true},"TOTALCLEARED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Target MW for end of period. Negative values when Bi-directional Unit is importing power, otherwise positive.","examples":["3.109","0","-1","685"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Unconstrained Intermittent Generation Forecast value provided to NEMDE","examples":["3.103","0","23","99"],"is_float":true},"VIOLATION5MINDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 5 min","is_float":true},"VIOLATION6SECDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 6 seconds","is_float":true},"VIOLATION60SECDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW 60 seconds","is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Violation MW energy","is_float":true},"DOWNEPF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used in Pre-Dispatch","unused":true,"is_float":true},"TRADETYPE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":8},"UPEPF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used in Pre-Dispatch","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHLOAD%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":18424409,"decompressed_size_all_time":15414339050},"visibility":"Private & Public Next-Day","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 30 minutes, with whole market data for the day before available as part of next day market data","pagination":["Elec47_1.htm"]},"PREDISPATCHOFFERTRK":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"OFFERTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec48.htm#100"],"comment":"PREDISPATCHOFFERTRK is for the ancillary service bid tracking of predispatch processing. PREDISPATCHOFFERTRK identifies which bids from BIDDAYOFFER and BIDOFFERPERIOD were applied for a given unit and ancillary service for each predispatch run.","description":"Source\n\nPREDISPATCHOFFERTRK updates every 30 minutes. The data is confidential\nto each participant until the next trading day.\n\nVolume\n\nApproximately 45,000 records per day.","primary_keys":["BIDTYPE","DUID","PERIODID","PREDISPATCHSEQNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid type Identifier - the ancillary service to which the bid applies","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["ADPBA1","ADPPV1","AGLHAL","AGLSOM","ALDGASF1","ANGAST1","APD01","ARWF1","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNAES1","ASNBRL1","ASNENC1","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASQENC1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE1","ASSENC1","ASSERDV1","ASTHYD1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBATTERY1","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUEGSF1","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVPS1","BOMENSF1","BOWWBA1","BOWWPV1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BRDDBES1","BRDDSF01","BRNDBES1","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CAPBES1","CATHROCK","CBWWBA1","CETHANA","CG1","CG2","CG3","CG4","CGBESS01","CHBESS1","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","COLUMSF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROOKWF3","CROWLWF1","CRURWF1","CRWARP1","CRWASF1","CSPVPS1","CTHLWF1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DPNTB1","DRACAN1","DRACAV1","DRAESN3","DRAESS1","DRBRLV01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DRHTVP03","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRVIOT07","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EDENVSF1","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","ERB01","ERB02","FINLYSF1","FISHER","FLYCRKWF","GANGARR1","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GNNDHSF1","GOESF1","GOONSF1","GORDON","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GRANWF1","GREENB1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUSF1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HEZ1","HILLSTN1","HPR1","HUMENSW","HUMEV","HUNTER1","HUNTER2","HVWWBA1","HVWWPV1","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KINGASF1","KPP_1","KSP1","LADBROK1","LADBROK2","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["2026090101"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101"],"unsigned_int":true,"num_int_bits":32},"BIDOFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Time this bid was processed and loaded","examples":["2020/09/14 15:09:17.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"BIDSETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Settlement date of bid applied","examples":["2020/09/14 00:00:00"],"parse_csv_as_string":true,"is_date":true},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHOFFERTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":31009857,"decompressed_size_all_time":25671287750},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes"},"PREDISPATCHPRICE":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"REGION_PRICES","VERSION":2}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec48.htm#109"],"comment":"PREDISPATCHPRICE records predispatch prices for each region by period for each predispatch run, including fields to handle the Ancillary Services functionality.","description":"PREDISPATCHPRICE data is public, so is available to all participants.\n\nSource\n\nPREDISPATCHPRICE updates with every thirty-minute predispatch run.","primary_keys":["DATETIME","REGIONID"],"indexes":[["LASTCHANGED"],["PREDISPATCHSEQNO"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"EEP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess energy price","examples":["0"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHPRICE."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional override price for 1 second FCAS lower","examples":["0.01","0","0.94"],"warnings":["This column does not appear in the official schema documentation, but does appear in the CSVs."],"is_float":true},"LOWER1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Lower 1Sec Price - RegionSolution element L1Price attribute","examples":["0.01","0","0.38"],"is_float":true},"LOWER5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","1","1.79"],"is_float":true},"LOWER6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","4.99538"],"is_float":true},"LOWER60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","6.99"],"is_float":true},"LOWERREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","1","170.15503","23200"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["01"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090508"],"unsigned_int":true,"num_int_bits":32},"RAISE1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional override price for 1 second FCAS raise","examples":["0.01","0","15","30"],"warnings":["This column does not appear in the official schema documentation, but does appear in the CSVs."],"is_float":true},"RAISE1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Raise 1Sec Price - R1Price attribute after capping /flooring","examples":["0.01","0","0.09"],"is_float":true},"RAISE5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.38"],"is_float":true},"RAISE6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","2.43714"],"is_float":true},"RAISE60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","3","1.68435"],"is_float":true},"RAISEREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","1","298.28","8"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","examples":["-0.31367","0.00002","0","184"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"LP Solver Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"EEP1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"EEP8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RRP8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHPRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":95302,"decompressed_size_all_time":134218020},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every thirty-minute pre-dispatch run"},"PREDISPATCHPRICESENSITIVITIES":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"PRICESENSITIVITIES","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec48.htm#120","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec48_1.htm"],"comment":"PREDISPATCHPRICESENSITIVITIES sets out the sensitivity prices for each region by period.","description":"Source\n\nThe plan is to provide this data every half-hour.","primary_keys":["DATETIME","REGIONID"],"indexes":[["PREDISPATCHSEQNO"],["LASTCHANGED"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period date and time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHPRICESENSITIVITIES."],"is_boolean":true},"INTERVENTION_ACTIVE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes","examples":["0"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:07:41"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.","examples":["1"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090508"],"unsigned_int":true,"num_int_bits":32},"RRPEEP1":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 1","examples":["-0.33903","0.00002","0","146"],"is_float":true},"RRPEEP2":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 2","examples":["-0.21924","0.00002","0","146"],"is_float":true},"RRPEEP3":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 3","examples":["-0.37859","0.00002","0","146"],"is_float":true},"RRPEEP4":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 4","examples":["-0.21924","0.00001","0","139"],"is_float":true},"RRPEEP5":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 5","examples":["-0.47121","0.00002","0","219"],"is_float":true},"RRPEEP6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 6","examples":["-0.21924","0.00003","0","130"],"is_float":true},"RRPEEP7":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 7","examples":["-0.47121","0.00001","0","262"],"is_float":true},"RRPEEP8":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 8","examples":["-0.33903","0.00002","0","184"],"is_float":true},"RRPEEP9":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 9","examples":["-0.21924","0.00002","0","146"],"is_float":true},"RRPEEP10":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 10","examples":["-0.15038","0.00002","0","146"],"is_float":true},"RRPEEP11":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 11","examples":["-0.07","0.00002","0","146"],"is_float":true},"RRPEEP12":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 12","examples":["-0.44921","0.00002","0","219"],"is_float":true},"RRPEEP13":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 13","examples":["-0.49445","0.00002","0","130"],"is_float":true},"RRPEEP14":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 14","examples":["-0.77667","0.00002","0","375"],"is_float":true},"RRPEEP15":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 15","examples":["-0.31037","0.00002","0","375"],"is_float":true},"RRPEEP16":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 16","examples":["-0.04178","0.00002","0","184"],"is_float":true},"RRPEEP17":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 17","examples":["-0.31359","0.00002","0","375"],"is_float":true},"RRPEEP18":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 18","examples":["-0.21924","0.00002","0","146"],"is_float":true},"RRPEEP19":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 19","examples":["-0.23558","0.00002","0","1001"],"is_float":true},"RRPEEP20":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 20","examples":["-0.01477","0.00002","0","146"],"is_float":true},"RRPEEP21":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 21","examples":["0"],"is_float":true},"RRPEEP22":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 22","examples":["0"],"is_float":true},"RRPEEP23":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 23","examples":["0"],"is_float":true},"RRPEEP24":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 24","examples":["0"],"is_float":true},"RRPEEP25":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 25","examples":["-0.16769","0.00003","0","375"],"is_float":true},"RRPEEP26":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 26","examples":["-0.48362","0.00003","0","146"],"is_float":true},"RRPEEP27":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 27","examples":["-0.1852","0.00003","0","375"],"is_float":true},"RRPEEP28":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 28","examples":["-0.00001","0.00003","0","138"],"is_float":true},"RRPEEP29":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 29","examples":["-0.31367","0.00002","0","184"],"is_float":true},"RRPEEP30":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 30","examples":["-0.31367","0.00002","0","146"],"is_float":true},"RRPEEP31":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 31","examples":["-0.31367","0.00002","0","146"],"is_float":true},"RRPEEP32":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 32","examples":["-0.31367","0.00001","0","146"],"is_float":true},"RRPEEP33":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 33","examples":["-0.31367","0.00001","0","146"],"is_float":true},"RRPEEP34":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 34","examples":["-0.31367","0.00002","0","146"],"is_float":true},"RRPEEP35":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 35","examples":["-0.47121","0.00001","0","253"],"is_float":true},"RRPEEP36":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 36","examples":["-0.46829","0.00002","0","184"],"is_float":true},"RRPEEP37":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 37","examples":["-0.46445","0.00002","0","184"],"is_float":true},"RRPEEP38":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 38","examples":["-0.47121","0.00002","0","184"],"is_float":true},"RRPEEP39":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 39","examples":["-0.46352","0.00002","0","184"],"is_float":true},"RRPEEP40":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 40","examples":["-0.47121","0.00002","0","146"],"is_float":true},"RRPEEP41":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 41","examples":["-0.03445","0.00002","0","184"],"is_float":true},"RRPEEP42":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 42","examples":["-0.47121","0.00002","0","23200"],"is_float":true},"RRPEEP43":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Energy Price for scenario 43","examples":["-0.30793","0.00002","0","1001"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"LP Solver Predispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHPRICESENSITIVITIES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":717910,"decompressed_size_all_time":1070326990},"visibility":"Public","trigger":"Every 30 minutes","pagination":["Elec48_1.htm"]},"PREDISPATCHREGIONSUM":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"REGION_SOLUTION","VERSION":9}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec49.htm#131","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec49_1.htm","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec49_2.htm"],"comment":"PREDISPATCHREGIONSUM sets out the overall regional Pre-Dispatch results for base case details (excluding price).","description":"PREDISPATCHREGIONSUM includes the forecast demand (total demand) and\nFrequency Control Ancillary Services (FCAS) requirements (specifically,\nfor the Raise Regulation and Lower Regulation Ancillary Services plus\nimprovements to demand calculations). PREDISPATCHREGIONSUM updates each\nhalf-hour with the latest Pre-Dispatch details for the remaining period.\n\nRegional demand can be calculated as total demand plus dispatchable load\n(i.e. Regional demand = Total Demand + Dispatchable Load)\n\nSource\n\nPREDISPATCHREGIONSUM updates every thirty minutes.\n\nNote\n\n\\*\\*\\* \"Actual FCAS availability\" is determined in a post-processing\nstep based on the energy target (TotalCleared) and bid FCAS trapezium\nfor that interval. However, if the unit is outside the bid FCAS\ntrapezium at the start of the interval (InitialMW), the \"Actual FCAS\navailability\" is set to zero. For regulation services, the trapezium is\nthe most restrictive of the bid/SCADA trapezium values.\n\nFrom 16 February 2006, the old reserve values are no longer populated\n(i.e. are null), being LORSurplus and LRCSurplus. For more details on\nthe changes to Reporting of Reserve Condition Data, refer to AEMO\nCommunication 2042. For the best available indicator of reserve\ncondition in each of the regions of the NEM for each trading interval,\nrefer to the latest run of the Pre-Dispatch PASA (see table\nPDPASA_REGIONSOLUTION).","primary_keys":["DATETIME","REGIONID"],"indexes":[["LASTCHANGED"],["PREDISPATCHSEQNO"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Period expressed as Date/Time","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"AVAILABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate generation bid available in region","examples":["1724.717","14304","16066.308"],"is_float":true},"AVAILABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate load bid available in region","examples":["0","64","2989"],"is_float":true},"BDU_CLEAREDMW_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of export (Generation)","examples":["0.77516","0","1","1383"],"is_float":true},"BDU_CLEAREDMW_LOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated cleared MW where the DUID type is BDU. Net of import (Load)","examples":["0.9265","0","1","1569"],"is_float":true},"BDU_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated energy storage where the DUID type is BDU (MWh)","examples":["104.64388","7700.74939"],"is_float":true},"BDU_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy Storage for BDU at the start of the interval(MWh) - Region Aggregated","examples":["178.70888","7631.42567"],"is_float":true},"BDU_MAX_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available generation side BDU summated for region (MW)","examples":["71","2530"],"is_float":true},"BDU_MIN_AVAIL":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total available load side BDU summated for region (MW)","examples":["19","2664"],"is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of cleared generation and import for region","examples":["996.16","831","8855.49","6444"],"is_float":true},"DECAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"generation availability taking into account daily energy constraints","examples":["1724.717","16066.308"],"is_float":true},"DECGEN_INITIAL_ENERGY_STORAGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy storage for Daily Energy Constrained Scheduled Generating Units at the start of the interval(MWh) - Region Aggregated","examples":["1995","68920"],"is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["928.217","947","8990.302","5311"],"is_float":true},"DEMANDFORECAST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Delta MW value only","examples":["0"],"is_float":true},"DISPATCHABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Generation dispatched in period","examples":["494.64","557","8318.62","1746"],"is_float":true},"DISPATCHABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load dispatched in period","examples":["0.93","0","1","1955"],"is_float":true},"EXCESSGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess generation in period / Deficit generation if VOLL","examples":["0"],"is_float":true},"INITIALSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of initial generation and import for region","examples":["822.21753","8848.19349"],"is_float":true},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHREGIONSUM."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Period date and time","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Lower1Sec availability (summated from UnitSolution)","examples":["40.00012","0","40","1191"],"is_float":true},"LOWER1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Lower1Sec Dispatched in Region - RegionSolution element L1Dispatch attribute","examples":["0.04","0","1","62"],"is_float":true},"LOWER5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 5min availability","examples":["6.00012","5","1384.13728","1403"],"is_float":true},"LOWER5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min local dispatch","examples":["2.77","0","1","230"],"is_float":true},"LOWER6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 6sec availability","examples":["6.00012","6","1454.473684","1453"],"is_float":true},"LOWER6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec local dispatch","examples":["2.82","0","1","264"],"is_float":true},"LOWER60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower 60sec availability","examples":["6.00012","6","1626.263158","1621"],"is_float":true},"LOWER60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec local dispatch","examples":["0.14","0","1","267"],"is_float":true},"LOWERREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted lower reg availability","examples":["3.80774","0","41","1696"],"is_float":true},"LOWERREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation local dispatch","examples":["3.91","0","1","145"],"is_float":true},"NETINTERCHANGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the regional reference node","examples":["-0.17","0.01","-118","1271"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PERIODID is just a period count, starting from 1 for each Pre-Dispatch run. Use DATETIME to determine half hour period.","examples":["01"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090508"],"unsigned_int":true,"num_int_bits":32},"RAISE1SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Trapezium adjusted Raise1Sec availability (summated from UnitSolution)","examples":["121.5","0","20","1346"],"is_float":true},"RAISE1SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Raise1Sec Dispatched in Region - RegionSolution element R1Dispatch attribute","examples":["1.07","0","3","206"],"is_float":true},"RAISE5MINACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 5min availability","examples":["38.042553","124","1453.66857","1494"],"is_float":true},"RAISE5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min local dispatch","examples":["4.01","0","1","306"],"is_float":true},"RAISE6SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 6sec availability","examples":["123.794369","143","1402.445713","1594"],"is_float":true},"RAISE6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec local dispatch","examples":["1.32","0","2","266"],"is_float":true},"RAISE60SECACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise 60sec availability","examples":["80.605465","165","1453.66857","1699"],"is_float":true},"RAISE60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec local dispatch","examples":["10.41","0","14","273"],"is_float":true},"RAISEREGACTUALAVAILABILITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"trapezium adjusted raise reg availability","examples":["15.7345","44","2917.63432","2594"],"is_float":true},"RAISEREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation local dispatch","examples":["8.01","0","1","180"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"LP Solver Pre-Dispatch run no, typically 1. It increments if the case is re-run.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SEMISCHEDULE_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW","examples":["94.227","4864.31416"],"is_float":true},"SEMISCHEDULE_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced","examples":["0.0002","0","4","1991"],"is_float":true},"SS_SOLAR_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Solar units in that region","examples":["0.001","0","4378.284"],"is_float":true},"SS_SOLAR_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is solar","examples":["0.001","0","10","3516.97837"],"is_float":true},"SS_SOLAR_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is solar","examples":["0.0002","0","3","106"],"is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is solar","examples":["0.001","0","3860","4378.284"],"is_float":true},"SS_WIND_AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"For Semi-Scheduled units. Aggregate Energy Availability from Wind units in that region","examples":["94.227","652","4584.539"],"is_float":true},"SS_WIND_CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where the primary fuel source is wind","examples":["65.162","652","3765.12"],"is_float":true},"SS_WIND_COMPLIANCEMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Semi-Schedule generator Cleared MW where Semi-Dispatch cap is enforced and the primary fuel source is wind","examples":["0.0021","0","20","1991"],"is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW) where the primary fuel source is wind","examples":["94.826","652","4599.052"],"is_float":true},"TOTALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total demand in MW for period (less normally on loads)","examples":["730.62","831","8839.39","8262"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["0.538","0","85","381.101"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["94.826","4561","5736.308"],"is_float":true},"WDR_AVAILABLE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated available MW for Wholesale Demand Response (WDR) units","examples":["0","1"],"is_float":true},"WDR_DISPATCHED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated dispatched MW for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"WDR_INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated MW value at start of interval for Wholesale Demand Response (WDR) units","examples":["0"],"is_float":true},"LORSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used after Feb 2006. Total short term generation capacity reserve used in assessing lack of reserve condition","unused":true,"is_float":true},"LOWER5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW dispatch","unused":true,"is_float":true},"LOWER5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW imported","unused":true,"is_float":true},"LOWER5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 5 min","unused":true,"is_float":true},"LOWER5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 5 min","unused":true,"is_float":true},"LOWER5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min total requirement","unused":true,"is_float":true},"LOWER5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 5 min","unused":true,"is_float":true},"LOWER5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min requirement","unused":true,"is_float":true},"LOWER6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW dispatch","unused":true,"is_float":true},"LOWER6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW imported","unused":true,"is_float":true},"LOWER6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec total requirement","unused":true,"is_float":true},"LOWER6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 seconds requirement","unused":true,"is_float":true},"LOWER60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW dispatch","unused":true,"is_float":true},"LOWER60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW imported","unused":true,"is_float":true},"LOWER60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec total requirement","unused":true,"is_float":true},"LOWER60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 seconds requirement","unused":true,"is_float":true},"LOWERREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation MW imported","unused":true,"is_float":true},"LOWERREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation local requirement","unused":true,"is_float":true},"LOWERREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg local requirement","unused":true,"is_float":true},"LOWERREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation total requirement","unused":true,"is_float":true},"LOWERREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg requirement","unused":true,"is_float":true},"LRCSURPLUS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used after Feb 2006. Total short term generation capacity reserve above the stated low reserve condition requirement","unused":true,"is_float":true},"RAISE5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW dispatch","unused":true,"is_float":true},"RAISE5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW imported","unused":true,"is_float":true},"RAISE5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 5 min","unused":true,"is_float":true},"RAISE5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 5 min","unused":true,"is_float":true},"RAISE5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min total requirement","unused":true,"is_float":true},"RAISE5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 5 min","unused":true,"is_float":true},"RAISE5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min requirement","unused":true,"is_float":true},"RAISE6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW dispatch","unused":true,"is_float":true},"RAISE6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW imported","unused":true,"is_float":true},"RAISE6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec total requirement","unused":true,"is_float":true},"RAISE6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 seconds requirement","unused":true,"is_float":true},"RAISE60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW dispatch","unused":true,"is_float":true},"RAISE60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW imported","unused":true,"is_float":true},"RAISE60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec total requirement","unused":true,"is_float":true},"RAISE60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 seconds requirement","unused":true,"is_float":true},"RAISEREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation MW imported","unused":true,"is_float":true},"RAISEREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation local requirement","unused":true,"is_float":true},"RAISEREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg local requirement","unused":true,"is_float":true},"RAISEREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation total requirement","unused":true,"is_float":true},"RAISEREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg requirement","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHREGIONSUM%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1057108,"decompressed_size_all_time":1117653270},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 30 minutes","pagination":["Elec49_1.htm","Elec49_2.htm"]},"PREDISPATCHSCENARIODEMAND":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"SCENARIO_DEMAND","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec50.htm#142"],"comment":"PREDISPATCHSCENARIODEMAND defines the demand offsets that are applied for each of the predispatch sensitivity scenarios.","primary_keys":["EFFECTIVEDATE","REGIONID","SCENARIO","VERSIONNO"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of this set of scenarios","examples":["1998/12/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region to which to apply the deltaMW for this SCENARIO.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCENARIO":{"sql_type":"NUMBER(2)","pl_type":"pl.UInt8","mandatory":true,"comment":"The scenario identifier.","examples":["1","43"],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"The version of this set of scenarios","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"DELTAMW":{"sql_type":"NUMBER(4)","pl_type":"pl.Int16","mandatory":false,"comment":"The MW offset that is applied for this scenario","examples":["0","-50","50","-500","1000"],"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHSCENARIODEMAND%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1912,"decompressed_size_all_time":2612340},"visibility":"Public","trigger":"When the predispatch scenario offset is updated"},"PREDISPATCHSCENARIODEMANDTRK":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"SCENARIO_DEMAND_TRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec50.htm#148"],"comment":"Tracks the predispatch scenario offset updates across time","primary_keys":["EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of this set of scenarios","examples":["1998/12/13 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"The version of this set of scenarios","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR(15)","pl_type":"str","mandatory":false,"comment":"The user that authorised the scenario update","examples":["MMS","TOM"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the scenario update was authorised","examples":["2008/05/15 09:45:27"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2008/05/15 09:45:27"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCHSCENARIODEMANDTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":516,"decompressed_size_all_time":681490},"visibility":"Public","trigger":"When the predispatch scenario offset is updated"},"PREDISPATCH_FCAS_REQ":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"REGIONFCASREQUIREMENT","VERSION":2,"hard_coded":true}]},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#865"],"comment":"PREDISPATCH_FCAS_REQ shows Predispatch Constraint tracking for Regional FCAS Requirements.","description":"Source\n\nPREDISPATCH_FCAS_REQ updates with each pre-dispatch run (half hourly)\n\nVolume\n\nApproximately 2,000 rows per day.\n\nNote\n\nThe PERIODID columns in tables PREDISPATCHCONSTRAINT and\nPREDISPATCH_FCAS_REQ have no consistent relationship with the other\nPERIODID values in the other tables in the PRE-DISPATCH package (such as\nPREDISPATCHPRICE). AEMO and many Participants appreciate the data model\nis inconsistent, but the cost of changing existing systems has been\njudged as being unjustifiable. An additional field DATETIME was added to\nallow joins between these data sets.","unused":true,"primary_keys":["BIDTYPE","DATETIME","GENCONID","REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time of trading interval","examples":["2025/05/21 19:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Generic Constraint ID - Join to table GenConData","examples":["D_I+BIP_ML2_L1","D_I+NIL_MG2_R1","D_T+NIL_BB_TG_R1","D_T+NIL_MG_R1","D_T+NIL_MG_RECL_R1","D_T+NIL_ML_L1","D_T+NIL_ML_RECL_L1","D_T+NIL_WF_TG_R1","F_I+BIP_ML_L1","F_I+BIP_ML_L5","F_I+BIP_ML_L6","F_I+BIP_ML_L60","F_I+GFT_TG_R1","F_I+GFT_TG_R5","F_I+GFT_TG_R6","F_I+GFT_TG_R60","F_I+LREG_0210","F_I+NIL_APD_TL_L1","F_I+NIL_APD_TL_L5","F_I+NIL_APD_TL_L6","F_I+NIL_APD_TL_L60","F_I+NIL_MG_R1","F_I+NIL_MG_R5","F_I+NIL_MG_R6","F_I+NIL_MG_R60","F_I+RREG_0220","F_I+TTS_TG_R1","F_I+TTS_TG_R5","F_I+TTS_TG_R6","F_I+TTS_TG_R60","F_MAIN++APD_TL_L1","F_MAIN++APD_TL_L5","F_MAIN++APD_TL_L6","F_MAIN++APD_TL_L60","F_MAIN++BIP_ML_L1","F_MAIN++BIP_ML_L5","F_MAIN++BIP_ML_L6","F_MAIN++BIP_ML_L60","F_MAIN++GFT_TG_R1","F_MAIN++GFT_TG_R5","F_MAIN++GFT_TG_R6","F_MAIN++GFT_TG_R60","F_MAIN++LREG_0210","F_MAIN++NIL_BL_L5","F_MAIN++NIL_BL_L6","F_MAIN++NIL_BL_L60","F_MAIN++NIL_BL_R5","F_MAIN++NIL_BL_R6","F_MAIN++NIL_BL_R60","F_MAIN++NIL_MG_R1","F_MAIN++NIL_MG_R5","F_MAIN++NIL_MG_R6","F_MAIN++NIL_MG_R60","F_MAIN++RREG_0220","F_MAIN++TTS_TG_R1","F_MAIN++TTS_TG_R5","F_MAIN++TTS_TG_R6","F_MAIN++TTS_TG_R60","F_MAIN+APD_TL_L1","F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L1","F_MAIN+BIP_ML_L5","F_MAIN+BIP_ML_L6","F_MAIN+BIP_ML_L60","F_MAIN+GFT_TG_R1","F_MAIN+GFT_TG_R5","F_MAIN+GFT_TG_R6","F_MAIN+GFT_TG_R60","F_MAIN+LREG_0210","F_MAIN+NIL_BL_L1","F_MAIN+NIL_BL_R1","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_MAIN+TTS_TG_R1","F_MAIN+TTS_TG_R5","F_MAIN+TTS_TG_R6","F_MAIN+TTS_TG_R60","F_T++GTTE_TL_L5","F_T++GTTE_TL_L6","F_T++GTTE_TL_L60","F_T++NIL_BB_TG_R5","F_T++NIL_BB_TG_R6","F_T++NIL_BB_TG_R60","F_T++NIL_MG_R5","F_T++NIL_MG_R6","F_T++NIL_MG_R60","F_T++NIL_MG_RECL_R5","F_T++NIL_MG_RECL_R6","F_T++NIL_MG_RECL_R60","F_T++NIL_ML_L5","F_T++NIL_ML_L6","F_T++NIL_ML_L60","F_T++NIL_ML_RECL_L5","F_T++NIL_ML_RECL_L6","F_T++NIL_ML_RECL_L60","F_T++NIL_WF_TG_R5","F_T++NIL_WF_TG_R6","F_T++NIL_WF_TG_R60","F_T+GTTE_TL_L5","F_T+GTTE_TL_L6","F_T+GTTE_TL_L60","F_T+LREG_0050","F_T+NIL_BB_TG_R5","F_T+NIL_BB_TG_R6","F_T+NIL_BB_TG_R60","F_T+NIL_MG_R5","F_T+NIL_MG_R6","F_T+NIL_MG_R60","F_T+NIL_MG_RECL_R5","F_T+NIL_MG_RECL_R6","F_T+NIL_MG_RECL_R60","F_T+NIL_ML_L5","F_T+NIL_ML_L6","F_T+NIL_ML_L60","F_T+NIL_ML_RECL_L5","F_T+NIL_ML_RECL_L6","F_T+NIL_ML_RECL_L60","F_T+NIL_WF_TG_R5","F_T+NIL_WF_TG_R6","F_T+NIL_WF_TG_R60","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220","F_T_NIL_MINP_R6"]},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region ID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, before the regulation/contingency split","examples":["2.7706","0","3295.45"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The base cost of the constraint for this service, before the regulation/contingency split","examples":["2.7706","0","3295.45"],"is_float":true},"ESTIMATED_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CMPF, based on dispatched data","examples":["5.18015","0","67.4055"],"is_float":true},"ESTIMATED_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"An estimated value for the constraint CRMPF, based on dispatched data","examples":["1.65349457","0","32.59449571"],"is_float":true},"GENCONEFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Generic Constraint EffectiveDate - Join to table GenConData","examples":["2013/08/21 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Generic Constraint Version number - Join to table GenConData","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERVENTION":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Intervention Flag","examples":["0"],"warnings":["Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCH_FCAS_REQ."],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2025/05/21 19:02:20"],"parse_csv_as_string":true,"is_s_datetime":true},"MARGINALVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal Value of generic constraint","examples":["0.04","0","38.77"],"is_float":true},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique period identifier, in the format yyyymmddpp. The period (pp) is 01 to 48, with 01 corresponding to the half-hour ending at 04:30am.","examples":["2025052131","2025052133"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"PreDispatch Sequence number","examples":["2025052131","2025052133"],"unsigned_int":true,"num_int_bits":32},"RECOVERY_FACTOR_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery factor for CMPF based recovery","examples":["2.68509011","0","34.64860479"],"is_float":true},"RECOVERY_FACTOR_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated recovery factor for CRMPF based recovery","examples":["0.00321718","0","0.04139866"],"is_float":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Case Run number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2025/MMSDM_2025_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCH_FCAS_REQ%23FILE01%23202505010000.zip","manifest_summary":{"first_month":{"year":2022,"month":4},"last_month":{"year":2025,"month":5},"compressed_size_per_month":3904270,"decompressed_size_all_time":68905708890},"visibility":"Public","trigger":"Every thirty-minute pre-dispatch run"},"PREDISPATCH_LOCAL_PRICE":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"LOCAL_PRICE","VERSION":1}],"transaction_type":"UPDATE-INSERT","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#25"],"comment":"Sets out local pricing offsets associated with each DUID connection point for each dispatch period","primary_keys":["DATETIME","DUID"],"indexes":[["DATETIME","DUID"]],"columns":{"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["AGLHAL","AGLSOM","ALDGASF1","ANGAST1","ARWF1","AVLSF1","BALB1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARRON-1","BARRON-2","BBATTERY1","BDL01","BDL02","BERYLSF1","BHB1","BLOWERNG","BLUFF1","BLYTHB1","BNGSF1","BNGSF2","BODWF1","BOMENSF1","BRDDSF01","BROKENH1","BRYB1WF1","BRYB2WF2","BULBES1","BULGANA1","BUNGAMB1","BUSF1","CALL_B_1","CALL_B_2","CATHROCK","CGBESS01","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","CLRKCWF1","CLRKCWF2","CNUNDAWF","COHUNSF1","COLEASF1","CPP_3","CPP_4","CROWLWF1","CRWARP1","CRWASF1","CSPVPS1","CUSF1","DALNTH1","DARLSF1","DARTM1","DAYDSF1","DPNTB1","DUNDWF1","DUNDWF2","DUNDWF3","EILDON1","EILDON2","ELAINWF1","EMERASF1","FINLYSF1","FLYCRKWF","GANNB1","GANNSF1","GESF1","GIRGSF","GLENSF1","GLRWNSF1","GOESF1","GOONSF1","GPWFEST1","GPWFEST2","GPWFEST3","GPWFWST1","GPWFWST2","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GUNNING1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESS1","HD1WF1","HDWF1","HDWF2","HDWF3","HILLSTN1","HPR1","HUMENSW","HUMEV","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPSF1","KEPWF1","KERNGSP1","KESSB1","KIAMSF1","KIATAWF1","KIDSPHG1","KIDSPHG2","KIDSPHL1","KIDSPHL2","KSP1","LADBROK1","LADBROK2","LANCSF1","LBB1","LGAPBS1","LGAPWF1","LGAPWF2","LILYSF1","LIMBESS1","LIMOSF11","LIMOSF21","LKBONNY1","LKBONNY2","LKBONNY3","LNGS1","LNGS2","LOYYB1","LOYYB2","LVES1","LYA1","LYA2","LYA3","LYA4","MACARTH1","MANNSF2","MANNUMB1","MANSLR1","MAPS2PV1","MAPS3PV1","MCKAY1","MERCER01","MEWF1","MIDDLSF1","MINTARO","MLB01","MOKOSF1","MOLNGSF1","MOORAWF1","MORTLK11","MORTLK12","MOUSF1","MREHA1","MREHA2","MREHA3","MRNBESS1","MRTLSWF1","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MTMILLAR","MUCRKSF1","MULWASF1","MURRAY","MUWAWF1","MUWAWF2","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NEVERSF1","NPS","NUMURSF1","NYNGAN1","OAKLAND1","ORABESS1","PAREPS1","PAREPW1","PARSF1","PIBESS1","PLBESS1","POR01","POR03","QPSFB1","QPSFB2","RANGEB1","RESS1","RIVNB2","RRSF1","RUGBYR1","RYANCWF1","SALTCRK1","SEBSF1","SMCSF1","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYP","SNUG1","SRSF1","STAN-1","STAN-2","STAN-3","STAN-4","STOCKYD1","STWF1","SUNRSF1","SUNTPSF1","TEMPB1","TRGBESS1","URANQ11","URANQ12","URANQ13","URANQ14","VBB1","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","WAGGNSF1","WATERLWF","WELLSF1","WELNSF1","WEMENSF1","WGWF1","WHITSF1","WINTSF1","WKIEWA1","WLWLSF1","WLWLSF2","WOOLES1","WOOLGSF1","WPWF","WSTWYSF1","WUNUSF1","WYASF1","YABULU","YABULU2","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 04:02:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOCAL_PRICE_ADJUSTMENT":{"sql_type":"NUMBER(10,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Constraint contribution cost of this unit: Sum(MarginalValue x Factor) for all relevant Constraints","examples":["-0.22","0.25","-26","-1025"],"is_float":true},"LOCALLY_CONSTRAINED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Key for Local_Price_Adjustment: 2 = at least one Outage Constraint; 1 = at least 1 System Normal Constraint (and no Outage Constraint); 0 = No System Normal or Outage Constraints","examples":["1","2"],"is_integer":true,"num_int_bits":8},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"A period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period","examples":["01"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30","examples":["2026090101","2026090110"],"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCH_LOCAL_PRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":611893,"decompressed_size_all_time":107898750},"visibility":"Private & Public Next-Day","trigger":"Every 30 minutes"},"PREDISPATCH_MNSPBIDTRK":{"package":"PRE_DISPATCH","pdr_config":{"mappings":[{"REPORT_NAME":"PREDISPATCH","REPORT_SUB_TYPE":"MNSPBIDTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#33"],"comment":"PREDISPATCH_MNSPBIDTRK shows the MNSP bid tracking, including the bid version used in each predispatch run for each MNSP Interconnector Link. PREDISPATCH_MNSPBIDTRK shows the audit trail of the bid used for each predispatch run.","description":"Source\n\nOwn (confidential) data updates every predispatch run. All bids are\navailable to all participants as part of next day market data.\n\nVolume\n\n1, 700, 000 per year","primary_keys":["LINKID","PERIODID","PREDISPATCHSEQNO"],"indexes":[["LASTCHANGED"]],"columns":{"LINKID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"BLNKTAS\", \"BLNKVIC\"])","mandatory":true,"comment":"Identifier for each of the two MNSP Interconnector Links. Each link pertains to the direction from and to.","examples":null,"enums":["BLNKTAS","BLNKVIC"]},"PERIODID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Trading Interval number","examples":["2026060101","2026060801"],"num_int_bits":16},"PREDISPATCHSEQNO":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Predispatch run identifier","examples":["2026060101","2026060722"],"unsigned_int":true,"num_int_bits":32},"DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Period expressed as Date/Time","examples":["2026/06/01 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Record creation timestamp","examples":["2026/06/01 04:01:42"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Time this bid was processed and loaded","examples":["2026/06/01 03:56:21.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant Identifier","examples":["BASSLINK"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Market Date from which bid is active","examples":["2026/06/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Version No. for given offer date and settlement date used","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_06/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PREDISPATCH_MNSPBIDTRK%23FILE01%23202606010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":6},"compressed_size_per_month":44457,"decompressed_size_all_time":50714370},"visibility":"Public","trigger":"After a pre-dispatch run"},"PRUDENTIALCOMPANYPOSITION":{"package":"PRUDENTIALS","pdr_config":{"mappings":[{"REPORT_NAME":"PRUDENTIAL","REPORT_SUB_TYPE":"COMPANY_POSITION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec69.htm#13"],"comment":"The prudential position of each company as at the datetime of a specific prudential run","primary_keys":["COMPANY_ID","PRUDENTIAL_DATE","RUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"COMPANY_ID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The company identifier","is_categorical":true},"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The prudential date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"The run number for the prudential date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CREDIT_SUPPORT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The Credit Support of the company at the time of the prudential run","is_float":true},"CURRENT_AMOUNT_BALANCE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The balance of the company for all unpaid billing weeks at the time of the prudential run","is_float":true},"DEFAULT_BALANCE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The balance of all defaults for the company at the time of the prudential run","is_float":true},"EARLY_PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The early payment amount deducted from Outstandings in the prudential run","is_float":true},"EXPOST_REALLOC_BALANCE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The balance of all ex-post reallocations for the company that were calculated outside of billing runs at the time of the prudential run","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MCL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The Maximum Credit Limit of the company at the time of the prudential run","is_float":true},"OUTSTANDINGS":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The total outstandings for the company at the time of the prudential run","is_float":true},"PERCENTAGE_OUTSTANDINGS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The percentage of outstandings calculated against the trading margin and prudential margin","is_float":true},"PRUDENTIAL_MARGIN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The prudential margin is the current value determined by AEMO for the registered participant. It represents the buffer below the value of credit support which is used to set the trading limit","is_float":true},"SECURITY_DEPOSIT_BALANCE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The balance of all active security deposits at the time of the prudential run","is_float":true},"SECURITY_DEPOSIT_OFFSET":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of all active security deposit application amounts at the time of the prudential run","is_float":true},"SECURITY_DEPOSIT_PROVISION":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of all active security deposit provision amounts at the time of the prudential run","is_float":true},"TRADING_LIMIT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The Trading Limit of the company at the time of the prudential run","is_float":true},"TRADING_MARGIN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The trading margin for the company at the time of the prudential run","is_float":true},"TYPICAL_ACCRUAL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The typical accrual for the company at the time of the prudential run","is_float":true}},"visibility":"Private","trigger":"Each prudential run"},"PRUDENTIALRUNTRK":{"package":"PRUDENTIALS","pdr_config":{"mappings":[{"REPORT_NAME":"PRUDENTIAL","REPORT_SUB_TYPE":"RUNTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec69.htm#21"],"comment":"Records the prudential run accepted by Settlements staff for each prudential date","primary_keys":["PRUDENTIAL_DATE","RUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The prudential date","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"The run number for the prudential date","examples":["1","26"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR(15)","pl_type":"str","mandatory":false,"comment":"The user that authorised the prudential run","examples":["JHUANG2","JKOUNIS","TOYONG"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the prudential run was authorised","examples":["2026/09/02 09:36:28"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The datetime that the record was last changed","examples":["2026/09/02 01:26:15"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23PRUDENTIALRUNTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":3030,"decompressed_size_all_time":2710010},"visibility":"Public","trigger":"Each prudential run"},"REALLOCATION":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETCFG","REPORT_SUB_TYPE":"REALLOCATION","VERSION":1},{"REPORT_NAME":"SETCFG","REPORT_SUB_TYPE":"REALLOCATION","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#76"],"comment":"The REALLOCATION table shows the financial transactions agreed between two participants that are settled through the AEMO pool settlements process.","description":"Note\n\nThe column REALLOCATION_TYPE can be used in conjunction with\nCREDITPARTICIPANT or DEBITPARTICIPANT to determine who submitted a\nreallocation.","primary_keys":["REALLOCATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Reallocation identifier"},"AGREEMENTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"SWAP\", \"CAP\", \"FLOOR\"])","mandatory":false,"comment":"$, (Quantity) Mwh, SWAP, CAP or FLOOR","examples":null,"enums":["SWAP","CAP","FLOOR"]},"CALENDARID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Unique ID of the calendar for which data is requested"},"CREDITPARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"The participant to be credited for the reallocation","is_categorical":true},"CREDITREFERENCE":{"sql_type":"VARCHAR2(400)","pl_type":"str","mandatory":false,"comment":"Optional reference detail for credit participant"},"CURRENT_STEPID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"SUBMITTED\", \"AUTHORISED\", \"CANCELLED\"])","mandatory":false,"comment":"Reallocation state. One of SUBMITTED, AUTHORISED, CANCELLED.","examples":null,"enums":["SUBMITTED","AUTHORISED","CANCELLED"]},"DAYTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BUSINESS\", \"NON_BUSINESS\", \"FLAT\"])","mandatory":false,"comment":"The day type profile for which the reallocation applies over the start and end date range. Valid entries are BUSINESS, NON_BUSINESS or FLAT.","examples":null,"enums":["BUSINESS","NON_BUSINESS","FLAT"]},"DEBITPARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"The participant to be debited for the reallocation","is_categorical":true},"DEBITREFERENCE":{"sql_type":"VARCHAR2(400)","pl_type":"str","mandatory":false,"comment":"Optional reference detail for debit participant"},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last day of the Reallocation contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVALLENGTH":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The length of settlement intervals (in minutes) in the reallocation profile","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REALLOCATION_TYPE":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Enum([\"C\", \"D\"])","mandatory":false,"comment":"Denotes a Credit or Debit reallocation with a value of \"C\" or \"D\" respectively","examples":null,"enums":["C","D"]},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier, being the spot price reference node for this reallocation","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"First day of the Reallocation contract","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"When two participants have settled through the AEMO pool settlements process"},"REALLOCATIONDETAILS":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#887"],"comment":"REALLOCATIONDETAILS sets out specific reallocation agreements.","description":"Not in Use - discontinued 10/06/2004\n\nSource\n\nAs changes occur.","unused":true,"primary_keys":["EFFECTIVEDATE","REALLOCATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar settlement date the agreement starts from","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identification of the reallocation agreement","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number on the effective date, highest is the reallocation used on that date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"User who authorised the record"},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the entry was authorised","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private"},"REALLOCATIONINTERVAL":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETCFG","REPORT_SUB_TYPE":"REALLOCATIONINTERVAL","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#85"],"comment":"30-minute or (5-minute for 5MS) data comprising a single reallocation transaction.","primary_keys":["PERIODID","REALLOCATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Reallocation identifier"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Nominated Reallocation Price, only used in agreement types of SWAP, CAP and FLOOR, being the contract strike price in $/MWh","is_float":true},"VALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reallocation value in the units of the agreement type","is_float":true}},"visibility":"Private","trigger":"30-minute or (5-minute for 5MS) data"},"REALLOCATIONINTERVALS":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#896"],"comment":"REALLOCATIONINTERVALS identifies the the reallocation agreement and provides the corresponding reallocation profiles submitted by the participant and accepted by AEMO","description":"Not in Use - discontinued 10/06/2004\n\nSource\n\nOnly populated if a reallocation contract has been submitted and\naccepted by AEMO.\n\nVolume\n\nGenerally 144 rows are inserted by week.","unused":true,"primary_keys":["EFFECTIVEDATE","PERIODID","REALLOCATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date the agreement starts from","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period number where period 1 use the half hour ended 00:30 EST","is_integer":true,"num_int_bits":16},"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identification of the reallocation agreement","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number on the effective date, highest is the reallocation used on that date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REALLOCATIONVALUE":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Either $ or MWh depending on agreement type","is_float":true}},"visibility":"Private","trigger":"When a reallocation contract has been submitted and accepted by AEMO"},"REALLOCATIONS":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#905"],"comment":"REALLOCATIONS shows reallocation agreement identifiers with corresponding start and end dates of submitted reallocations as accepted by AEMO.","description":"Not in Use - discontinued 10/06/2004\n\nSource\n\nThis view is populated upon submission of a reallocation contract and\naccepted by AEMO.\n\nVolume\n\nGenerally 3 rows are inserted by week.","unused":true,"primary_keys":["REALLOCATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Identification of the reallocation agreement"},"AGREEMENTTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"$\", \"MWh\"])","mandatory":false,"comment":"Either $ or MWh","examples":null,"enums":["$","MWh"]},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Ending date for the agreement","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENDPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Ending period number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTFROMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Participant who provides the money"},"PARTICIPANTTOID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant who receives the money","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Place where the RRP is taken for the agreement","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Starting data for the agreement","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STARTPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Starting period number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEREGISTRATIONDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Not used","examples":["2026/01/20 00:05:00"],"unused":true,"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"DEREGISTRATIONPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":16}},"visibility":"Private"},"REGION":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"REGION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#100"],"comment":"REGION sets out valid region IDs.","description":"REGION data is public, so is available to all participants.\n\nSource\n\nREGION updates if a change is ever made to a region. This table is\nstatic data and is likely to change very infrequently.","primary_keys":["REGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"DESCRIPTION":{"sql_type":"VARCHAR2(64)","pl_type":"str","mandatory":false,"comment":"Full description of region","examples":["New South Wales","Queensland Region","Snowy Regions","South Australia Region","Tasmanian Region","Victoria"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2004/06/11 10:43:05"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONSTATUS":{"sql_type":"VARCHAR2(8)","pl_type":"pl.Categorical","mandatory":false,"comment":"Status of the region e.g. working, inactive, archive.","examples":["Active","INACTIVE"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23REGION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":504,"decompressed_size_all_time":664370},"visibility":"Public","trigger":"When there is change to a region"},"REGIONAPC":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"AP","REPORT_SUB_TYPE":"REGIONAPC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#71"],"comment":"REGIONAPC defines Administered Price profiles (Energy and FCAS) for a region.","description":"REGIONAPC data is public, so is available to all participants.\n\nSource\n\nREGIONAPC updates when a change is ever made to the Administered Price\nCap details. Changes to this table are infrequent.","primary_keys":["EFFECTIVEDATE","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date the APC profile applies from","examples":["1998/11/27 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the same date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Authorised by","examples":["ALANH","BFLEMING","BRIGONI","BWEBB","CBROWNLEE","HAMISHM","IGNAZIOR","LACHLANL","LEON","PRYAN","PSANDERS","RGILLETT","RMOGG"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["1998/12/02 07:10:23"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/11/27 18:26:28"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23REGIONAPC%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1319,"decompressed_size_all_time":1724870},"visibility":"Public","trigger":"When an Administered Price Cap occurs"},"REGIONAPCINTERVALS":{"package":"FORCE_MAJEURE","pdr_config":{"mappings":[{"REPORT_NAME":"AP","REPORT_SUB_TYPE":"REGIONAPCINTERVALS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.htm#80"],"comment":"REGIONAPCINTERVALS contains Administered Price profiles (Energy and FCAS) applicable to each interval for a region.","description":"REGIONAPCINTERVALS data is public, so is available to all participants.\n\nSource\n\nREGIONAPCINTERVALS is updated whenever an Administered Price Cap occurs.","primary_keys":["EFFECTIVEDATE","PERIODID","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date the APC profile applies from","examples":["1998/11/27 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"30-minute period","examples":["1","48"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the same date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"APCVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Administered price cap in $","examples":["5","300"],"is_float":true},"APFVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Administered price floor in $","is_float":true},"FCASAPCVALUE":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"FCAS Administered price cap in $","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/12/02 07:12:15"],"parse_csv_as_string":true,"is_s_datetime":true},"APCTYPE":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":false,"comment":"not used","unused":true,"is_integer":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23REGIONAPCINTERVALS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":11180,"decompressed_size_all_time":12237810},"visibility":"Public","trigger":"When an Administered Price Cap occurs"},"REGIONFCASRELAXATION_OCD":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#914"],"comment":"REGIONFCASRELAXATION_OCD contains details of regional FCAS requirements relaxed in the over-constrained dispatch (OCD) re-run (if there was one).\nNote: INTERVENTION is not included in REGIONFCASRELAXATION_OCD since the relaxation of the FCAS requirement is the same amount in both intervened and non-intervened cases.","description":"REGIONFCASRELAXATION_OCD data is public, so is available to all\nparticipants.\n\nSource\n\nThe occurrences of Over-constrained dispatch (OCD) re-runs are ad hoc,\nwith significant dependencies on the configuration or events in the\nphysical power system.\n\nVolume\n\nRows per day: ~2\n\nMb per month: \\<1\n\nThe estimates on the number of rows are based on a 1% occurrence rate\nfor OCD runs.\n\nNote\n\nThe DISPATCHCASESOLUTION results report with the existing CASESUBTYPE\nfield as “OCD” when detecting over-constrained dispatch.","unused":true,"primary_keys":["GLOBAL","REGIONID","RUNNO","SERVICETYPE","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"GLOBAL":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":true,"comment":"FCAS Requirement: 1 = global, 0 = local","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SERVICETYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Ancillary service type identifier (e.g. LOWER60SEC)","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date and time of the dispatch interval","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REQUIREMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Relaxed Requirement used in attempt to avoid violation","is_float":true}},"visibility":"Public","trigger":"Ad hoc, when there are occurrences of Over-constrained dispatch (OCD) re-runs"},"REGIONSTANDINGDATA":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"REGIONSTANDINGDATA","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#115"],"comment":"REGIONSTANDINGDATA sets out standing region data including the region reference node.","description":"REGIONSTANDINGDATA data is public, so is available to all participants.\n\nSource\n\nREGIONSTANDINGDATA only changes when a change is made to a region. This\ntable changes infrequently.","primary_keys":["EFFECTIVEDATE","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective date of this record, only the latest date applies","examples":["2026/04/27 12:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of the standing data that should be effective on this date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["BATCH","LUKEB","MIBRAHIM","NORRIS","TOM"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["1997/11/04 11:16:11"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2006/06/01 00:00:58"],"parse_csv_as_string":true,"is_s_datetime":true},"PEAKTRADINGPERIOD":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Period identifier of the peak trading period of this connection point","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONALREFERENCEPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"unique id of a connection point, being the reference point for this region","examples":["NREF1","QREF1","SAREF1","SNREF1","TREF1","VREF1"],"is_categorical":true},"RSOID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"the unique identifier of the participant with responsibility for the region.","examples":["NRSO","QLDRSO"],"is_categorical":true},"SCALINGFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Scaling factor for regional FCAS requirement","examples":["1"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23REGIONSTANDINGDATA%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":660,"decompressed_size_all_time":824260},"visibility":"Public","trigger":"When there is change to a region"},"REGION_AREA":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"REGION_AREA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#109"],"comment":"Table containing static metadata for mapping the Areas to Regions. The latest mapping can be obtained for each RegionID using the most recent EffectiveDate and then VersionNo.","primary_keys":["AREAID","EFFECTIVEDATE","REGIONID","VERSIONNO"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier","is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar date from when this record set is effective.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number for the same effectivedate.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Ad hoc when Area-Region mappings are updated or added"},"RESDEMANDTRK":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#130"],"comment":"RESDEMANDTRK defines the existence and versioning information of a forecast for a specific region and trading date.\nRESDEMANDTRK and PERDEMAND have a parent/child relationship, and are for defined forecast regional demands since market start. RESDEMANDTRK defines the existence and versioning information of a forecast for a specific region and trading date. PERDEMAND defines the numerical forecast values for each trading interval of a the trading day for that region. A complete trading day forecast for one region consists of one RESDEMANDTRK record and 48 PERDEMAND records.","description":"RESDEMANDTRK data is public, so is available to all participants.\n\nSource\n\nRESDEMANDTRK updates are ad hoc.\n\nVolume\n\n27000 rows per year.","primary_keys":["EFFECTIVEDATE","OFFERDATE","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trading Date of the regional forecast","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Date the forecast was created","examples":["2026/08/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of this forecast with respect to the Effectivedate and Offerdate","examples":["2","48"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Identifier of authorising user","examples":["AEMO\\sa_r_"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date forecast authorised","examples":["2026/08/25 12:57:01"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Tracking purposes only"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was last modified","examples":["2026/08/25 12:57:10"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESDEMANDTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":149576,"decompressed_size_all_time":675489110},"visibility":"Public","trigger":"Ad hoc"},"RESERVE":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"RESERVE_DATA","REPORT_SUB_TYPE":"RESERVE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#923"],"comment":"RESERVE sets out specific reserve requirements for dispatch, predispatch and STPASA, for each half-hour interval by region. Updates show as new versions for a date.","description":"Two fields specify Frequency Controlled Ancillary Services requirements\nfor the regulation ancillary services. Another two fields specify the\nLack of Reserve levels to be applied in the ST PASA solver.\n\nChange Notice 324 (for the FCAS Constraint enhancements project) means\nthat Dispatch no longer utilises the static FCAS requirements defined in\nthe DELTAMW and RESERVE tables. These tables are replaced with\nconstraint data as a source of FCAS requirements.\n\nRESERVE data is public, so is available to all participants.\n\nSource\n\nRESERVE updates as AEMO updates forecasts, daily.","unused":true,"primary_keys":["PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Market Trading Interval","examples":["1","48"],"is_integer":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Differentiates this region from all other regions","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Market date starting at 04:00am","examples":["2018/05/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version No of record for this date, the version of the file loaded to produce these reserve figures","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2018/05/02 13:44:34"],"parse_csv_as_string":true,"is_s_datetime":true},"LOADREJECTIONRESERVEREQ":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"PASA Load rejection reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":64},"LOR1LEVEL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"PASA Lack of Reserve 1 Level","examples":["420","600"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LOR2LEVEL":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"PASA Lack of Reserve 1 Level","examples":["220","350"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LOWER5MIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Lower 5 minute reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32},"LOWER6SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Lower 6 second reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32},"LOWER60SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Lower 60 second reserve requirement","is_integer":true,"num_int_bits":32},"LOWERREG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Lower Regulation reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32},"PASARESERVE":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"PASA reserve requirement","examples":["-268"],"is_integer":true,"num_int_bits":32},"RAISE5MIN":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Raise 5 minute reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32},"RAISE6SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.Int32","mandatory":false,"comment":"Raise 6 second reserve requirement","is_integer":true,"num_int_bits":32},"RAISE60SEC":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Raise 60 second reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32},"RAISEREG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Raise Regulation reserve requirement","is_integer":true,"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2018/MMSDM_2018_05/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_RESERVE_201805010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2018,"month":5},"has_missing_months":true,"compressed_size_per_month":698,"decompressed_size_all_time":668040},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Daily when AEMO updates forecasts"},"RESIDUECONTRACTPAYMENTS":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"RESIDUECONTRACTPAYMENTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#154"],"comment":"RESIDUECONTRACTPAYMENTS shows Settlement Residue Auction payment Participant notifications.","description":"RESIDUECONTRACTPAYMENTS data is confidential to the relevant\nparticipant.","primary_keys":["CONTRACTID","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract ID","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Ad hoc"},"RESIDUEFILETRK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_BIDS","REPORT_SUB_TYPE":"FILE_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#163"],"comment":"RESIDUEFILETRK records all Settlement Residue Auction offers submitted by participants.","description":"RESIDUEFILETRK data is confidential to each participant\n\nSource\n\nRESIDUEFILETRK updates are ad hoc from participants\n\nVolume\n\nAssuming quarterly contracts RESIDUEFILETRK contains a maximum of 5,000\nrecords per annum.\n\nEach bid file can contain many bids for each auction. Participants can\ninput multiple bids (with the last acknowledged file being used in the\nauction).","primary_keys":["AUCTIONID","LOADDATE","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Unique id for each auction date. (new in March 2003 to support SRA Inter-Temporal Linking)"},"LOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date-Time SRA offer was loaded","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"ACKFILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"SRA acknowledgment file name"},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"SRA ContractID","is_categorical":true},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"SRA offer file name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"SUCCESSFUL\", \"CORRUPT\"])","mandatory":false,"comment":"Load status [SUCCESSFUL/CORRUPT]","examples":null,"enums":["SUCCESSFUL","CORRUPT"]}},"visibility":"Private","trigger":"Ad hoc"},"RESIDUE_BID_TRK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_BID_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#64"],"comment":"RESIDUE_BID_TRK supports the Settlement Residue Auction, by detailing which bid was used for which SRA Contract run.","description":"Source\n\nRESIDUE_BID_TRK updates are usually quarterly from participants before\nan Auction.\n\nRESIDUE_BID_TRK data is confidential to the relevant participant.\n\nRESIDUE_BID_TRK excludes contracts and versions without a valid\npublication date (i.e invalid bids are ignored).\n\nVolume\n\nAssuming monthly contracts, RESIDUE_BID_TRK shows a maximum of 500\nrecords per year.","primary_keys":["AUCTIONID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Unique id for each auction date. (new in March 2003 to support SRA Inter-Temporal Linking)"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of participant","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version of Bid used","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BIDLOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time bid used","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"SRA Contract unique identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Updated quarterly before an auction"},"RESIDUE_CONTRACTS":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CONTRACTS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#100"],"comment":"RESIDUE_CONTRACTS supports the Settlement Residue Auction, by holding the contract details for each period for which a residue contract will be offered.","description":"RESIDUE_CONTRACTS data is public, so is available to all participants.\n\nSource\n\nRESIDUE_CONTRACTS updates are quarterly by AEMO.\n\nVolume\n\nAssuming quarterly contracts, RESIDUE_CONTRACTS contains a maximum of 50\nrecords per year.","primary_keys":["CONTRACTYEAR","QUARTER","TRANCHE"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Contracted Year","examples":["2026","2029"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":true,"comment":"SRA Contracted Quarter","examples":["1","4"],"is_integer":true,"num_int_bits":8},"TRANCHE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Label identifying the arbitrary segmented share of the Interconnector flow","examples":["1","12"],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"AUCTIONDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Close date of bidding, calculated as RAUCDATE business days before the contract start date","examples":["2026/09/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Unique id for each auction date (new in March 2003 to support SRA Inter-Temporal Linking)","examples":["A202609"]},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of authorising officer or process","examples":["SYSTEM"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorisation date for this record","examples":["2026/08/13 10:50:05"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CALCMETHOD":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Identifies methodology used"},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique identifier for each SRA Contract as specified by AEMO","examples":["C2026Q4T12","C2027Q1T11","C2027Q2T10","C2027Q3T09","C2027Q4T08","C2028Q1T07","C2028Q2T06","C2028Q3T05","C2028Q4T04","C2029Q1T03","C2029Q2T02","C2029Q3T01"],"is_categorical":true},"DESCRIPTION":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Description of Contract"},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"SRA Quarter end date","examples":["2026/12/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 10:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NOTIFYBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of notifying person","examples":["SYSTEM"]},"NOTIFYDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Open date of bidding, calculated as RNOTIFYDATE business days before the auction date","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"NOTIFYPOSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date notification posted","examples":["2026/09/01 10:00:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"POSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date of publishing the auction results","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"POSTEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of publishing officer or process"},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"SRA Quarter start date","examples":["2026/10/01 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESIDUE_CONTRACTS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":3},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":697,"decompressed_size_all_time":703760},"visibility":"Public","trigger":"Updated quarterly"},"RESIDUE_CON_DATA":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_DATA","VERSION":1},{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_DATA","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#73"],"comment":"RESIDUE_CON_DATA supports the Settlement Residue Auction, by holding for each participant the confidential data from the auction. RESIDUE_CON_DATA joins to RESIDUE_PUBLIC_DATA and RESIDUE_TRK.","description":"Source\n\nRESIDUE_CON_DATA refreshes whenever a Settlement Residue Auction is run\n(i.e. quarterly).\n\nRESIDUE_CON_DATA data is confidential to the relevant participant.\n\nRESIDUE_CON_DATA excludes contracts and versions without a valid\npublication date (i.e invalid bids are ignored).\n\nVolume\n\nRESIDUE_CON_DATA shows a maximum of 6000 records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of Contracted Participant","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract run version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LINKPAYMENT":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment due (i.e. total purchase price)","is_float":true},"SECONDARY_UNITS_SOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The number of cancelled Units for all Auction Participants.","is_float":true},"UNITSPURCHASED":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Units purchased on the directional interconnector (i.e. Contracted quantity)","is_float":true}},"visibility":"Private","trigger":"On auction completion"},"RESIDUE_CON_ESTIMATES_TRK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_ESTIMATES_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#82"],"comment":"RESIDUE_CON_ESTIMATES_TRK supports the Settlement Residue Auction, by holding the tracking details of the estimates used to generate the reserve price for each contract.","description":"Source\n\nRESIDUE_CON_ESTIMATES_TRK updates are quarterly by SRA team.\n\nVolume\n\nAssuming monthly contracts, RESIDUE_CON_ESTIMATES_TRK shows a maximum of\n50 records per year.","primary_keys":["CONTRACTID","CONTRACTYEAR","QUARTER","VALUATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting in week containing 1st January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"QUARTER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":true,"comment":"Contract Quarter","is_integer":true,"unsigned_int":true,"num_int_bits":8},"VALUATIONID":{"sql_type":"VARCHAR2(15)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of the estimator","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Version of a record, as nominated by the participant","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Public","trigger":"Updated quarterly"},"RESIDUE_CON_FUNDS":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_CON_FUNDS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#91"],"comment":"RESIDUE_CON_FUNDS supports the Settlement Residue Auction, by holding the fund details for each contract.","description":"RESIDUE_CON_FUNDS data is public, so is available to all participants.\n\nSource\n\nRESIDUE_CON_FUNDS updates are quarterly from SRA team via SRIS\ninterface.\n\nVolume\n\nAssuming quarterly contracts, RESIDUE_CON_FUNDS contains a maximum of\n600 records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier as specified by AEMO","examples":["C2026Q4T12","C2027Q1T11","C2027Q1T12","C2027Q2T10","C2027Q2T11","C2027Q2T12","C2027Q3T09","C2027Q3T10","C2027Q3T11","C2027Q3T12","C2027Q4T08","C2027Q4T09","C2027Q4T10","C2027Q4T11","C2027Q4T12","C2028Q1T07","C2028Q1T08","C2028Q1T09","C2028Q1T10","C2028Q1T11","C2028Q1T12","C2028Q2T06","C2028Q2T07","C2028Q2T08","C2028Q2T09","C2028Q2T10","C2028Q2T11","C2028Q2T12","C2028Q3T05","C2028Q3T06","C2028Q3T07","C2028Q3T08","C2028Q3T09","C2028Q3T10","C2028Q3T11","C2028Q3T12","C2028Q4T04","C2028Q4T05","C2028Q4T06","C2028Q4T07","C2028Q4T08","C2028Q4T09","C2028Q4T10","C2028Q4T11","C2028Q4T12","C2029Q1T03","C2029Q1T04","C2029Q1T05","C2029Q1T06","C2029Q1T07","C2029Q1T08","C2029Q1T09","C2029Q1T10","C2029Q1T11","C2029Q1T12","C2029Q2T02","C2029Q2T03","C2029Q2T04","C2029Q2T05","C2029Q2T06","C2029Q2T07","C2029Q2T08","C2029Q2T09","C2029Q2T10","C2029Q2T11","C2029Q2T12","C2029Q3T01","C2029Q3T02","C2029Q3T03","C2029Q3T04","C2029Q3T05","C2029Q3T06","C2029Q3T07","C2029Q3T08","C2029Q3T09","C2029Q3T10","C2029Q3T11","C2029Q3T12","C2029Q4T01","C2029Q4T02","C2029Q4T03","C2029Q4T04","C2029Q4T05","C2029Q4T06","C2029Q4T07","C2029Q4T08","C2029Q4T09","C2029Q4T10","C2029Q4T11","C2029Q4T12","C2030Q1T01","C2030Q1T02","C2030Q1T03","C2030Q1T04","C2030Q1T05","C2030Q1T06","C2030Q1T07","C2030Q1T08","C2030Q1T09","C2030Q1T10","C2030Q1T11","C2030Q2T01","C2030Q2T02","C2030Q2T03","C2030Q2T04","C2030Q2T05","C2030Q2T06","C2030Q2T07","C2030Q2T08","C2030Q2T09","C2030Q2T10","C2030Q3T01","C2030Q3T02","C2030Q3T03","C2030Q3T04","C2030Q3T05","C2030Q3T06","C2030Q3T07","C2030Q3T08","C2030Q3T09","C2030Q4T01","C2030Q4T02","C2030Q4T03","C2030Q4T04","C2030Q4T05","C2030Q4T06","C2030Q4T07","C2030Q4T08","C2031Q1T01","C2031Q1T02","C2031Q1T03","C2031Q1T04","C2031Q1T05","C2031Q1T06","C2031Q1T07","C2031Q2T01","C2031Q2T02","C2031Q2T03","C2031Q2T04","C2031Q2T05","C2031Q2T06","C2031Q3T01","C2031Q3T02","C2031Q3T03","C2031Q3T04","C2031Q3T05","C2031Q4T01","C2031Q4T02","C2031Q4T03","C2031Q4T04","C2032Q1T01","C2032Q1T02","C2032Q1T03","C2032Q2T01","C2032Q2T02","C2032Q3T01"],"is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier for the Contracted Interconnector","examples":["NSW1-SA1"],"is_categorical":true},"ACTUALRESERVEPRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Actual reserve price","examples":["0"],"is_float":true},"DEFAULTUNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Actual number of units allocated based on the auction default percentage for the tranche and the total number of units to be auctioned for this quarter","examples":["66","800"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/08/13 10:50:05"],"parse_csv_as_string":true,"is_s_datetime":true},"MEANRESERVEPRICE":{"sql_type":"NUMBER(9,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Average reserve price calculated from the selected estimates","examples":["0"],"is_float":true},"REALLOCATEDUNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Units reallocated from the previous tranche of this quarter because they were not taken up by the participant","examples":["0"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"ROLLOVERUNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Units reallocated from the previous tranche of this quarter","examples":["0"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"SCALEFACTOR":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Scaling factor for regional Frequency control Ancillary Service requirement","examples":["0"],"is_float":true},"UNITSOFFERED":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Total units offered for Contract","examples":["66","800"],"is_integer":true,"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_08/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESIDUE_CON_FUNDS%23FILE01%23202608010000.zip","manifest_summary":{"first_month":{"year":2015,"month":5},"last_month":{"year":2026,"month":8},"has_missing_months":true,"compressed_size_per_month":2084,"decompressed_size_all_time":463600},"visibility":"Public","trigger":"Updated quarterly"},"RESIDUE_FUNDS_BID":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION_BIDS","REPORT_SUB_TYPE":"FUNDS_BID","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#109"],"comment":"RESIDUE_FUNDS_BID supports the Settlement Residue Auction, by showing the fund details for each SRA bid by each Participant.","description":"Source\n\nParticipant's bid file.\n\nRESIDUE_FUNDS_BID data is confidential to the relevant participant.\nRESIDUE_FUNDS_BID shows a maximum of 30,000 records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","LOADDATE","OPTIONID","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","is_categorical":true},"LOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and time the batcher loaded the SRA offer","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OPTIONID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Unique option identifier (1..20)","is_integer":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"UNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Quantity of units bid for","is_integer":true,"unsigned_int":true,"num_int_bits":32}},"visibility":"Private"},"RESIDUE_PRICE_BID":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_PRICE_BID","VERSION":1},{"REPORT_NAME":"IRAUCTION_BIDS","REPORT_SUB_TYPE":"PRICE_BID","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#118"],"comment":"RESIDUE_PRICE_BID supports the Settlement Residue Auction, holding the unit and bid price details for each participant.","description":"Source\n\nThe participant's own bid file\n\nRESIDUE_PRICE_BID data is confidential to the relevant participant.\n\nThe public version of the data is available to all auction participants\npost the associated auction date in RESIDUE_PRICE_FUNDS_BID.\n\nVolume\n\nRESIDUE_PRICE_BID shows a maximum of 10,000 records per year.","primary_keys":["AUCTIONID","LOADDATE","OPTIONID","PARTICIPANTID"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique id for each auction date (new in March 2003 to support SRA Inter-Temporal Linking)","is_categorical":true},"LOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time the batcher loaded the bid","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OPTIONID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique option (bid) identifier (1..800)","is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"BIDPRICE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price offered for each unit","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not to be used. Unique id for each SRA contract (specified by AEMO)","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Upon participants making a bid"},"RESIDUE_PRICE_FUNDS_BID":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_PRICE_FUNDS_BID","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#127"],"comment":"RESIDUE_PRICE_FUNDS_BIDshows the bids producing the auction outcome, without exposing participant-specific details. RESIDUE_PRICE_FUNDS_BID is new in March 2003 to support SRA Inter-Temporal Linking.","description":"RESIDUE_PRICE_FUNDS_BID data is public. The data is available to all\nauction participants post the associated auction date.\n\nVolume\n\nThe volume is very dependent on the number of active bids. An indication\nis about 250,000 per year.","primary_keys":["AUCTIONID","CONTRACTID","FROMREGIONID","INTERCONNECTORID","LINKEDBIDFLAG"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique id for each auction date","examples":["A202609"],"is_categorical":true},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique id for each contract specified by AEMO","examples":["C2026Q4T12","C2027Q1T11","C2027Q2T10","C2027Q3T09","C2027Q4T08","C2028Q1T07","C2028Q2T06","C2028Q3T05","C2028Q4T04","C2029Q1T03","C2029Q2T02","C2029Q3T01"],"is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Unique region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique interconnector identifier","examples":["NSW1-QLD1","NSW1-SA1","T-V-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"LINKEDBIDFLAG":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":true,"comment":"A unique option id, with respect to the auction, created to show which bid elements are linked.","examples":["601","1600"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"BIDPRICE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Price bid for each unit","examples":["1.08","69","6333.6","23184"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/09/15 14:00:05"],"parse_csv_as_string":true,"is_s_datetime":true},"UNITS":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Quantity of units bid","examples":["1","60"],"is_integer":true,"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESIDUE_PRICE_FUNDS_BID%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":3},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":128298,"decompressed_size_all_time":38436010},"visibility":"Public","trigger":"Updated  after an auction"},"RESIDUE_PUBLIC_DATA":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_PUBLIC_DATA","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#136"],"comment":"RESIDUE_PUBLIC_DATA shows the public auction results.\nRESIDUE_PUBLIC_DATA supports the Settlement Residue Auction, by holding the public details of the auction for a given contract. RESIDUE_PUBLIC_DATA joins to RESIDUE_CON_DATA and RESIDUE.","description":"RESIDUE_PUBLIC_DATA excludes contracts and versions without a valid\npublication date (i.e. invalid bids are ignored).\n\nThe data is available to all auction participants post the associated\nauction date.\n\nSource\n\nRESIDUE_PUBLIC_DATA updates are quarterly from NEMMCO.\n\nVolume\n\nRESIDUE_PUBLIC_DATA shows a maximum of 120 records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique id for each contract to be specified by AEMO","examples":["C2026Q4T12","C2027Q1T11","C2027Q2T10","C2027Q3T09","C2027Q4T08","C2028Q1T07","C2028Q2T06","C2028Q3T05","C2028Q4T04","C2029Q1T03","C2029Q2T02","C2029Q3T01"],"is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique interconnector identifier","examples":["NSW1-QLD1","NSW1-SA1","T-V-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version Number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLEARINGPRICE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Clearing price","examples":["748.19","720","21800.44","20858"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last changed","examples":["2026/09/15 14:00:12"],"parse_csv_as_string":true,"is_s_datetime":true},"RESERVEPRICE":{"sql_type":"NUMBER(17,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve price","examples":["0"],"is_float":true},"UNITSOFFERED":{"sql_type":"NUMBER(5,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Total units offered for auction","examples":["41","841"],"is_integer":true,"unsigned_int":true,"num_int_bits":32},"UNITSSOLD":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Units Sold (modified format and usage in March 2003 to support SRA Inter-Temporal Linking)","examples":["41","800"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESIDUE_PUBLIC_DATA%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":3},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":1961,"decompressed_size_all_time":4851410},"visibility":"Public","trigger":"Updated quarterly"},"RESIDUE_TRK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"RESIDUE_TRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#145"],"comment":"RESIDUE_TRK supports the Settlement Residue Auction, by showing the tracking records for different residue auction runs. RESIDUE_TRK joins to RESIDUE_PUBLIC_DATA and RESIDUE_CON_DATA.","description":"Source\n\nRESIDUE_TRK updates whenever Settlement Residue Auctions are run and the\nresults published (i.e. quarterly).\n\nThe RESIDUE_TRK data is available to all participants post the\nassociated auction date.\n\nVolume\n\nAssuming quarterly contracts, RESIDUE_TRK shows a maximum of 50 records\nper year.","primary_keys":["AUCTIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":true,"comment":"Unique id for each auction date. (new in March 2003 to support SRA Inter-Temporal Linking)","examples":["A202609"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Contract run version","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorising officer or process","examples":["YCHEN"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Date results published","examples":["2026/09/15 00:00:00"],"parse_csv_as_string":true,"is_date":true},"CONTRACTID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"SRA Contract identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/15 14:16:03"],"parse_csv_as_string":true,"is_s_datetime":true},"POSTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the run is authorised","examples":["2026/09/15 14:16:03"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"POSTEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Name of authorising officer or process","examples":["SYSTEM"]},"RUNDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date auction results determined","examples":["2026/09/15 14:00:08"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(15)","pl_type":"pl.Enum([\"SUCCESSFUL\", \"CORRUPT\"])","mandatory":false,"comment":"Load status [SUCCESSFUL/CORRUPT]","examples":null,"enums":["SUCCESSFUL","CORRUPT"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23RESIDUE_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":3},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":439,"decompressed_size_all_time":310380},"visibility":"Public","trigger":"Updated  after an auction"},"ROOFTOP_PV_ACTUAL":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"ROOFTOP","REPORT_SUB_TYPE":"ACTUAL","VERSION":1},{"REPORT_NAME":"ROOFTOP","REPORT_SUB_TYPE":"ACTUAL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#139"],"comment":"Estimate of regional Rooftop Solar actual generation for each half-hour interval in a day. AEMO plans to remove this table in a Data Model version release after 5.6.","primary_keys":["INTERVAL_DATETIME","REGIONID","TYPE"],"indexes":[["INTERVAL_DATETIME","TYPE","REGIONID"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The forecast half-hour interval (time ending)","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLDN\", \"QLDC\", \"QLDS\", \"QLD1\", \"TASN\", \"TASS\", \"TAS1\", \"NSW1\", \"VIC1\", \"SA1\"])","mandatory":true,"comment":"Region identifier","examples":null,"warnings":["Unlike most tables, in older months, `REGIONID` can include `QLDN`, `QLDC`, `QLDS`, `TASN`, `TASC` to refer to north/central/south of the state."],"enums":["QLDN","QLDC","QLDS","QLD1","TASN","TASS","TAS1","NSW1","VIC1","SA1"]},"TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"DAILY\", \"MEASUREMENT\", \"SATELLITE\"])","mandatory":true,"comment":"One of DAILY, MEASUREMENT or SATELLITE. DAILY- best quality estimated actuals, available day after. MEASUREMENT- best quality estimated actuals on day, delayed by 1 half hour. SATELLITE- estimated actuals using satellite imagery, delayed by 1 half hour.","examples":null,"enums":["DAILY","MEASUREMENT","SATELLITE"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:49:01"],"parse_csv_as_string":true,"is_s_datetime":true},"POWER":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Estimated generation in MW at the interval end","examples":["0.024","0","5471.955"],"is_float":true},"QI":{"sql_type":"NUMBER(2,1)","pl_type":"pl.Float64","mandatory":false,"comment":"Quality indicator. Represents the quality of the estimate.","examples":["0.6","1","0.7"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23ROOFTOP_PV_ACTUAL%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2016,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":103506,"decompressed_size_all_time":194307580},"visibility":"Public","trigger":"Event timing â every 30 minutes"},"ROOFTOP_PV_ACTUAL_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_ACTUAL_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#147"],"comment":"Contains predictions for rooftop PV area estimated actuals, with a 5-minute and 30-minute resolution for different estimate types. This is the child table of the parent table ROOFTOP_PV_ACTUAL_RUN, which contains the corresponding actual prediction runs.","primary_keys":["AREAID","ESTIMATE_TYPE","INTERVAL_DATETIME","INTERVAL_DURATION","OFFERDATETIME","PREDICTION_PRIORITY","PREDICTION_RUN_DATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"ESTIMATE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of Rooftop PV estimate, for example, MEASURED, SATELLITE and so on.","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date and Time the forecast applies (dispatch interval ending).","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERVAL_DURATION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Duration of each interval (in minutes) for this prediction, for example, 5 or 30.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this prediction submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDICTION_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of prediction run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"PREDICTION_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) from which this prediction run is valid.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"PREDICTION_QUALITY":{"sql_type":"NUMBER(2,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Prediction quality. Higher number represents better quality.","is_integer":true,"unsigned_int":true,"num_int_bits":8},"PREDICTION_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Prediction value in MW.","is_float":true}},"visibility":"Public","trigger":"Every 5 or 30 minutes when a new rooftop PV estimated actual is available, covering the most recent 5 or 30-minute interval that is available"},"ROOFTOP_PV_ACTUAL_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_ACTUAL_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#153"],"comment":"Contains prediction runs for rooftop PV area estimated actuals, with a 5-minute and 30-minute resolution for different estimate types. This is the parent table to the child table ROOFTOP_PV_ACTUAL_PRED, which contains the corresponding actual predictions.","primary_keys":["AREAID","ESTIMATE_TYPE","INTERVAL_DURATION","OFFERDATETIME","PREDICTION_PRIORITY","PREDICTION_RUN_DATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"ESTIMATE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of Rooftop PV estimate, for example, MEASURED, SATELLITE and so on.","is_categorical":true},"INTERVAL_DURATION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Duration of each interval (in minutes) for this prediction, for example, 5 or 30.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this prediction submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREDICTION_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Priority of prediction run, higher number is used in preference to lower number for the same provider.","is_integer":true,"unsigned_int":true,"num_int_bits":64},"PREDICTION_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) from which this prediction run is valid.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"INSTALLED_CAPACITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Installed rooftop PV capacity used for the prediction run, in MW.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the prediction run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the prediction run."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the prediction run."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the prediction run was suppressed by the provider when submitted. Suppressed predictions are not used by downstream forecasting systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true}},"visibility":"Public","trigger":"Every 5 or 30 minutes when a new rooftop PV estimated actual is available, covering the most recent 5 or 30-minute interval that is available"},"ROOFTOP_PV_FCST_P5_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_P5_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#159"],"comment":"Contains forecast predictions for rooftop PV areas, with a 5-minute resolution over the hour-ahead DS/P5MIN timeframe. This is the child table of the parent table ROOFTOP_PV_FCST_P5_RUN, which contains the corresponding forecast runs.","primary_keys":["AREAID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","FORECAST_TYPE","INTERVAL_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas."},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed in which case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of forecast, for example, POE_10, POE_50, POE_90, MEAN and so on.","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval-ending) for the period that this forecast applies to, within the current forecast_run_datetime.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"FORECAST_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast value in MW.","is_float":true}},"visibility":"Public","trigger":"Every 5 minutes when a new rooftop PV forecast is available, covering the 2 hours ahead horizon with 5-minute resolution"},"ROOFTOP_PV_FCST_P5_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_P5_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#165"],"comment":"Contains forecast runs for rooftop PV areas, with a 5-minute resolution over the hour-ahead DS/P5MIN timeframe. This is the parent table to the child table ROOFTOP_PV_FCST_P5_PRED, which contains the corresponding forecast predictions over the full horizon.","primary_keys":["AREAID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"unsigned_int":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"INSTALLED_CAPACITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Installed rooftop PV capacity that was used for the forecast run, in MW.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the forecast run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the forecast run."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast run."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the forecast run was suppressed by the provider when submitted. Suppressed forecasts are not used by downstream systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true}},"visibility":"Public","trigger":"Every 5 minutes when a new rooftop PV forecast is available, covering the 2 hours ahead horizon with 5-minute resolution"},"ROOFTOP_PV_FCST_PRED":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_PRED","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#171"],"comment":"Contains forecast predictions for rooftop PV areas, with a 30-minute resolution over the week-ahead PD/STPASA timeframe. This is the child table of the parent table ROOFTOP_PV_FCST_RUN, which contains the corresponding forecast runs.","primary_keys":["AREAID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","FORECAST_TYPE","INTERVAL_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"unsigned_int":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"FORECAST_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Type of forecast, for example, POE_10, POE_50, POE_90, MEAN and so on.","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval-ending) for the period that this forecast applies to, within the current forecast_run_datetime.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"FORECAST_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast value in MW.","is_float":true}},"visibility":"Public","trigger":"Every 30 minutes when a new rooftop PV forecast is available, covering the 8 days ahead horizon with 30-minute resolution"},"ROOFTOP_PV_FCST_RUN":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"DEMAND","REPORT_SUB_TYPE":"ROOFTOP_PV_FCST_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#177"],"comment":"Contains forecast runs for rooftop PV areas, with a 30-minute resolution over the week-ahead PD/STPASA timeframe. This is the parent table to the child table ROOFTOP_PV_FCST_PRED, which contains the corresponding forecast predictions over the full horizon.","primary_keys":["AREAID","FORECAST_PRIORITY","FORECAST_RUN_DATETIME","OFFERDATETIME","PROVIDERID"],"columns":{"AREAID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Area identifier, aligning with the load forecasting areas.","is_categorical":true},"FORECAST_PRIORITY":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Priority of forecast run, higher number is used in preference to lower number for the same provider.","is_integer":true,"num_int_bits":64},"FORECAST_RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime (interval ending) when this forecast run is valid. It aligns with run_datetime in downstream processes, unless a forecast run is missed, in this case the previous run is used.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime when this forecast submission was loaded.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROVIDERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Forecast provider identifier, for example, AEMO, PROVIDER_A and so on.","is_categorical":true},"INSTALLED_CAPACITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Installed rooftop PV capacity that was used for the forecast run, in MW.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the forecast run was written into AEMO database.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MODEL_USED":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Metadata describing the model used to produce the forecast run."},"PROVIDER_TIMESTAMP":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Datetime when the provider created the forecast.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REMARKS":{"sql_type":"VARCHAR2(300)","pl_type":"str","mandatory":false,"comment":"Comments relating to the forecast run."},"SUPPRESSED_PROVIDER":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag indicating if the forecast run was suppressed by the provider when submitted. Suppressed forecasts are not used by downstream systems. Suppressed = 1, Unsuppressed = 0.","is_boolean":true}},"visibility":"Public","trigger":"Every 30 minutes when a new rooftop PV forecast is available, covering the 8 days ahead horizon with 30-minute resolution"},"ROOFTOP_PV_FORECAST":{"package":"DEMAND_FORECASTS","pdr_config":{"mappings":[{"REPORT_NAME":"ROOFTOP","REPORT_SUB_TYPE":"FORECAST","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.htm#183"],"comment":"Regional forecasts of Rooftop Solar generation across the half-hour intervals over 8 days. AEMO plans to remove this table in a Data Model version release after 5.6.","primary_keys":["INTERVAL_DATETIME","REGIONID","VERSION_DATETIME"],"indexes":[["VERSION_DATETIME","INTERVAL_DATETIME","REGIONID"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The forecast half-hour interval (time ending)","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLDN\", \"QLDC\", \"QLDS\", \"QLD1\", \"TASN\", \"TASS\", \"TAS1\", \"NSW1\", \"VIC1\", \"SA1\"])","mandatory":true,"comment":"Region identifier","examples":null,"warnings":["Unlike most tables, in older months, `REGIONID` can include `QLDN`, `QLDC`, `QLDS`, `TASN`, `TASC` to refer to north/central/south of the state."],"enums":["QLDN","QLDC","QLDS","QLD1","TASN","TASS","TAS1","NSW1","VIC1","SA1"]},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date time this forecast was produced","examples":["2026/09/01 00:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:21:58"],"parse_csv_as_string":true,"is_s_datetime":true},"POWERMEAN":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The average forecast value in MW at the interval end","examples":["3.309","0","5394.546"],"is_float":true},"POWERPOE50":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"50% probability of exceedance forecast value in MW at the interval end","examples":["0.006","0","5380.704"],"is_float":true},"POWERPOEHIGH":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"10% probability of exceedance forecast value in MW at the interval end","examples":["0.026","0","1907","5806.39"],"is_float":true},"POWERPOELOW":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"90% probability of exceedance forecast value in MW at the interval end","examples":["0.001","0","4807.35"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23ROOFTOP_PV_FORECAST%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2016,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":34987332,"decompressed_size_all_time":35097809850},"visibility":"Public","trigger":"Every 30 minutes over 8 days"},"SECDEPOSIT_INTEREST_RATE":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"SECDEPOSIT_INTEREST_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#46"],"comment":"The security deposit interest rate on a daily basis. This is the public table published when the business enter and authorise a new daily interest rate","description":"SECDEPOSIT_INTEREST_RATE data is public to all participants.","primary_keys":["EFFECTIVEDATE","INTEREST_ACCT_ID","VERSION_DATETIME"],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The effective date of the interest rate change","examples":["2018/02/07 00:00:00"],"parse_csv_as_string":true,"is_date":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The interest account ID for calculating the interest payment","examples":["SDA"],"is_categorical":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date Time this record was added","examples":["2018/02/27 09:02:17"],"parse_csv_as_string":true,"is_s_datetime":true},"INTEREST_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The interest rate for the interest account ID as on the effective date.","examples":["0.3","1.7"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SECDEPOSIT_INTEREST_RATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":912,"decompressed_size_all_time":237100},"visibility":"Public","trigger":"Upon entering and authorising the security deposit provision and interest rate"},"SECDEPOSIT_PROVISION":{"package":"BILLING_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"BILLING_CONFIG","REPORT_SUB_TYPE":"SECDEPOSIT_PROVISION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.htm#53"],"comment":"The security deposit provision entry details","primary_keys":["PARTICIPANTID","SECURITY_DEPOSIT_ID"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant ID linked to the security deposit ID","is_categorical":true},"SECURITY_DEPOSIT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The security deposit ID"},"AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The security deposit amount","is_float":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The Interest Account ID for calculating the Interest Payment. This is NULL if the INTEREST_CALC_TYPE = FIXED"},"INTEREST_CALC_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"FIXED\", \"DAILY\"])","mandatory":false,"comment":"FIXED OR DAILY","examples":null,"enums":["FIXED","DAILY"]},"INTEREST_RATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The interest rate assigned to the security deposit ID. Null if INTEREST_CALC_TYPE <> FIXED","is_float":true},"MATURITY_CONTRACTYEAR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The contract year of the billing week when the security deposit is maturing","is_integer":true,"unsigned_int":true,"num_int_bits":16},"MATURITY_WEEKNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The week no of the billing week when the security deposit is maturing","is_integer":true,"unsigned_int":true,"num_int_bits":16},"TRANSACTION_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date the security deposit ID is entered and authorised by settlements","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"Upon entering and authorising the security deposit provision and interest rate"},"SETAGCPAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#995"],"comment":"SETAGCPAYMENT sets out specific payment details for Automatic Generation Control (AGC) services by period.","description":"SETAGCPAYMENT data is confidential to the relevant participant\n\nSource\n\nSETAGCPAYMENT updates with each settlement run.","unused":true,"primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Period Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared MW of Unit in Enabled Dispatch period","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"AS contract version no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EBP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Eligible Bid Price","is_float":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial MW of Unit in Enabled Dispatch period","warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor of Unit","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETAGCRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1006"],"comment":"SETAGCRECOVERY shows reimbursements for Automatic Generation Control (AGC) Ancillary Services to be recovered from participants.","description":"SETAGCRECOVERY data is confidential to the relevant participant\n\nSource\n\nSETAGCRECOVERY updates with each settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"is_categorical":true},"ENABLINGRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery","is_float":true},"ENABLINGRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand for Generator","is_float":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","unused":true,"is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETAPCCOMPENSATION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1015"],"comment":"SETAPCCOMPENSATION shows Administered Price Cap (APC) compensation payments for each period.","description":"SETAPCCOMPENSATION data is confidential to the relevant participant.\n\nSource\n\nSETAPCCOMPENSATION updates in settlement runs, as needed.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period (based on calendar day)","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"APCCOMPENSATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"APC amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to SET_APC_COMPENSATION","category":"related_tables"}],"trigger":"Each settlement run"},"SETAPCRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1024"],"comment":"SETAPCRECOVERY shows reimbursements for Administered Price Cap (APC) to be recovered from participants.","description":"SETAPCRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETAPCRECOVERY updates with each settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period (based on calendar day)","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"APCRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"APC Recovery amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant MW Demand","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total region demand","is_float":true},"TOTALCOMPENSATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total compensation","is_float":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to SET_APC_RECOVERY","category":"related_tables"}],"trigger":"Each settlement run"},"SETCFG_PARTICIPANT_MPF":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"SETCFG_PARTICIPANT_MPF","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#93"],"comment":"SETCFG_PARTICIPANT_MPF shows the Market Participation Factors (MPF) for each participant for each connection point. The MPF values are used to determine recovery amounts for regulation FCAS.","description":"SETCFG_PARTICIPANT_MPF data is available to all participants.\n\nVolume\n\nApproximately 20,000 records per year","primary_keys":["CONNECTIONPOINTID","EFFECTIVEDATE","PARTICIPANTCATEGORYID","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","examples":["NASSHU02","QASSHU01","QSPS1S","QSPT1S","QWSB3W","STB31T","STET1T","VJL21W"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of the MPF data","examples":["2026/09/08 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Category","examples":["GENERATOR"],"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","examples":["DIAMTEMP","SHUBMASP","SNODE1","TBBESS","WANDBESS","WOORBESS"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of the MPF data","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/04 15:07:18"],"parse_csv_as_string":true,"is_s_datetime":true},"MPF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Market Participation Factor","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCFG_PARTICIPANT_MPF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":593,"decompressed_size_all_time":7758460},"visibility":"Public","trigger":"When Market Participation Factors (MPF) data is updated"},"SETCFG_PARTICIPANT_MPFTRK":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENT_CONFIG","REPORT_SUB_TYPE":"SETCFG_PARTICIPANT_MPFTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#102"],"comment":"SETCFG_PARTICIPANT_MPFTRK is the tracking table for Market Participation Factors (MPF) data stored in the SETCFG_PARTICIPANT_MPF table for each participant.","description":"SETCFG_PARTICIPANT_MPFTRK data is public, so is available to all\nparticipants.\n\nVolume\n\nApproximately 2,000 records per year","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of the MPF data","examples":["2026/09/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","examples":["AGLWBESS","DIAMTEMP","HEPBURN","SHUBMASP","SNODE1","TBBESS","WANDBESS","WOORBESS","ZENENGEN"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of the MPF data","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"Authorising user","examples":["AMULINGBAYAN","DMICALLEF","JHO","JLOVERING"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date and time","examples":["2026/09/02 13:24:29"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/02 13:24:30"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCFG_PARTICIPANT_MPFTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":635,"decompressed_size_all_time":2485090},"visibility":"Public","trigger":"When Market Participation Factors (MPF) data is updated"},"SETCFG_SAPS_SETT_PRICE":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETCFG","REPORT_SUB_TYPE":"SAPS_SETT_PRICE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#111"],"comment":"The Settlement Price for SAPS Energy in each Region","primary_keys":["FROMDATE","REGIONID","TODATE","VERSION_DATETIME"],"columns":{"FROMDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The From Date of the SAPS Pricing Application Period","examples":["2023/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region ID for which the calculated SAPS Price is applicable","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"TODATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The To Date of the SAPS Pricing Application Period","examples":["2024/06/30 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Date time of the record generation","examples":["2023/06/08 00:10:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ISFIRM":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Whether the SAPS Price is Firm or Non-Firm","examples":["0","1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record","examples":["2023/06/08 00:10:04"],"parse_csv_as_string":true,"is_s_datetime":true},"SAPS_RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region Reference Price for SAPS in the Region","examples":["33.73","43","118.16","93"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCFG_SAPS_SETT_PRICE%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":7},"compressed_size_per_month":14224,"decompressed_size_all_time":2182330},"visibility":"Public","trigger":"When records for Settlement Price for SAPS Energy in each region are added or modified"},"SETCFG_WDRRR_CALENDAR":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS_CONFIG","REPORT_SUB_TYPE":"WDRRR_CALENDAR","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#123"],"comment":"Wholesale Demand Response Reimbursement Rate Calendar","primary_keys":["REGIONID","VERSION_DATETIME","WDRRRPERIOD"],"columns":{"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Identifier for the region id","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSION_DATETIME":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Version Date time of the latest changes.","examples":["2021/09/30 00:00:00.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"WDRRRPERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the period to which the WDRRR applies. For quarter-based periods, this will be equal to YYYY[Q]NN, for example,2020Q3 for 2020 Quarter 3.","examples":["2021Q3","2021Q4","2022Q1","2022Q2","2022Q3","2022Q4","2023Q1","2023Q2","2023Q3","2023Q4","2024Q1","2024Q2","2024Q3","2024Q4","2025Q1","2025Q2","2025Q3","2025Q4","2026Q1","2026Q2","2026Q3","2026Q4","2027Q1","2027Q2","2027Q3","2027Q4"],"is_categorical":true},"ENDDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"End Date of Period (Inclusive).","examples":["2021/09/30 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record.","examples":["2021/10/01 00:00:00.000"],"parse_csv_as_string":true,"is_ms_datetime":true},"STARTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"Start Date of Period (Inclusive).","examples":["2021/07/01 00:00:00"],"parse_csv_as_string":true,"is_date":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCFG_WDRRR_CALENDAR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1290,"decompressed_size_all_time":285710},"visibility":"Public","trigger":"When records are added or modified"},"SETCFG_WDR_REIMBURSE_RATE":{"package":"SETTLEMENT_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS_CONFIG","REPORT_SUB_TYPE":"WDR_REIMBURSE_RATE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec54.htm#117"],"comment":"Settlements WDR transactions","primary_keys":["REGIONID","VERSION_DATETIME","WDRRRPERIOD"],"columns":{"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique identifier for the region","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSION_DATETIME":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Version Date time of the latest changes.","examples":["2021/10/26 09:15:10.363"],"parse_csv_as_string":true,"is_ms_datetime":true},"WDRRRPERIOD":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the period to which the WDRRR applies. For quarter-based periods, this will be equal to YYYY[Q]NN, e.g. 2020Q3 for 2020 Quarter 3.","examples":["2021Q4","2022Q1","2022Q2","2022Q3","2022Q4","2023Q1","2023Q2","2023Q3","2023Q4","2024Q1","2024Q2","2024Q3","2024Q4","2025Q1","2025Q2","2025Q3","2025Q4","2026Q1","2026Q2","2026Q3","2026Q4"],"is_categorical":true},"ISFIRM":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"A flag to indicate that the WDRRR value is FIRM for the period and region, i.e. it is based on a complete set of firm prices from dispatch. Possible Values are 1 and 0","examples":["1"],"is_boolean":true},"LASTCHANGED":{"sql_type":"TIMESTAMP(3)","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2021/10/26 09:15:10.363"],"parse_csv_as_string":true,"is_ms_datetime":true},"WDRRR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDRRR value for the period and region ($/MWh)","examples":["38.05475424","279.31682147"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCFG_WDR_REIMBURSE_RATE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":3076,"decompressed_size_all_time":671390},"visibility":"Public","trigger":"Generated quarterly"},"SETCPDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1033"],"comment":"SETCPDATA shows meter settlement data for each connection point. This is the key view for retailers to verify energy charges. A regional summary view is also provided. As the view has values for each connection point by period, for each meter data file, it is a very large view. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, SET_ENERGY_TRANSACTIONS and SET_ENERGY_GENSET_DETAIL replace SETCPDATA.","description":"The Connection point details (in SETCPDATA) are confidential to the\nparticipant and host retailer that the connection points relate to. By\ncomparison, the regional data (SETCPDATAREGION) is publically available.\n\nSource\n\nSETCPDATA updates with each Settlement run.","unused":true,"primary_keys":["MDA","PARTICIPANTID","PERIODID","SETTLEMENTDATE","TCPID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Metering Data Agent"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":64},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TCPID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection point identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":64},"AFE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Accounted For Energy for this Market Customer FRMP and TNI in the Settlements Trading Interval, excluding any UFEA component","is_float":true},"AGE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Adjusted Gross Energy for this Market Customer FRMP and TNI in the Settlements Trading Interval. When GS commences, this includes the UFEA amount in the settlement runs.","is_float":true},"CPEEP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Connection Point Excess Energy Price = EEP * TLF","is_float":true},"CPRRP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Connection Point Price = RRP * TLF","is_float":true},"DME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ME- for all NMIs at this Market Customer FRMP and TNI in the Settlements Trading Interval.","is_float":true},"EEP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess Energy Price","is_float":true},"EP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"settlement amount in $ for trading period","is_float":true},"EXPORTENERGYCOST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total cost of energy purchased at the connection point by the participant in this settlement interval","is_float":true},"IGENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Import Gross energy into the pool - MWh","is_float":true},"IMPORTENERGYCOST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total cost of energy sold at the connection point by the participant in this settlement interval","is_float":true},"INENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Import Nett energy into the pool - MWh, plus UFEA if the UFEA amount is positive. When GS commences, this includes the UFEA amount in the settlement runs.","is_float":true},"IPOWER":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Import reactive power","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"METERRUNNO":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"Meter Run Number = version number of the meter file","is_integer":true,"unsigned_int":true,"num_int_bits":64},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(20,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export - Import of Net energy (MWh)","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"UFEA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Share of UFE allocated to this FRMP and TNI in the Settlements Trading Interval.","is_float":true},"XGENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Gross energy from the pool - MWh","is_float":true},"XNENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Nett energy from the pool - MWh, plus (UFEA * -1) if the UFEA amount is negative. When GS commences, this includes the UFEA amount in the settlement runs.","is_float":true},"XPOWER":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export reactive power","is_float":true},"APC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"HOSTDISTRIBUTOR":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Not used","unused":true},"RESC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RESP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETCPDATAREGION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"CPDATAREGION","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1044"],"comment":"SETCPDATAREGION sets out summary meter settlement data for each region. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, SET_ENERGY_REGION_SUMMARY replace SETCPDATAREGION.","description":"SETCPDATAREGION data is public, so is available to all participants.\n\nSource\n\nSETCPDATAREGION is a summary based on grouping on SETCPDATA and is\nupdated with each settlement run.","unused":true,"primary_keys":["PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(22,10)","pl_type":"pl.Float64","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","200"],"is_float":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2024/05/05 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(22,10)","pl_type":"pl.Float64","mandatory":true,"comment":"Settlement run no","examples":["12"],"is_float":true,"unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"current system date, to enable automatic replication","examples":["2024/11/25 07:51:48"],"parse_csv_as_string":true,"is_s_datetime":true},"SUMEP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of energy price across the region","is_float":true},"SUMIGENERGY":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Import Gross energy into the pool - MWh","is_float":true},"SUMINENERGY":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Import Nett energy into the pool - MWh","examples":["0.69175","134.41807"],"is_float":true},"SUMXGENERGY":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Gross energy from the pool - MWh","is_float":true},"SUMXNENERGY":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Nett energy from the pool - MWh","examples":["-93.77479","-685.4649"],"is_float":true},"SUMIPOWER":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":128},"SUMXPOWER":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Not used","unused":true,"is_integer":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_12/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETCPDATAREGION%23FILE01%23202412010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":12},"has_missing_months":true,"compressed_size_per_month":549263,"decompressed_size_all_time":2061004350},"visibility":"Public","trigger":"After each settlement run"},"SETFCASCOMP":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1053"],"comment":"SETFCASCOMP shows the compensation details for Frequency Controlled Ancillary Services (FCAS). These compensation values are calculated by a separate “what if” run of the LP Solver and entered as an unconstrained MW value into settlements.","description":"SETFCASCOMP data is confidential to the relevant participant\n\nSource\n\nSETFCASCOMP updates with each Settlement run, if required.","unused":true,"primary_keys":["DUID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CCPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared MW of Unit in First Dispatch period in Trading Interval","is_float":true},"EBP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Eligible Bid Price","is_float":true},"EXCESSGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess Generation Payment in trading interval","is_float":true},"FCASCOMP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control AS Compensation payment to Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor of Unit","is_float":true},"UNCONSTRAINEDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial MW of Unit in First Dispatch period in Trading Interval","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETFCASRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1062"],"comment":"SETFCASERECOVERY shows reimbursements for the Frequency Control Ancillary Services compensation.","description":"Status\n\nSETFCASERECOVERY is obsolete since the implementation of Ancillary\nServices Review. For more details, see Change Notice 126.\n\nConfidential to the participant\n\nSource\n\nThis view is updated with each Settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Period identifier","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FCASCOMP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Ancillary Service Compensation Payment","is_float":true},"FCASRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Ancillary Service recovery amount.","is_float":true},"FCASRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Frequency Control Ancillary Service recovery amount for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and Time last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand for Generator","is_float":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to SET_FCAS_RECOVERY","category":"related_tables"}],"trigger":"Each settlement run"},"SETFCASREGIONRECOVERY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCASREGIONRECOVERY","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#206"],"comment":"The FCAS Recovery amount from each NEM Region and the Energy MWh used for the FCAS Recovery calculation from Participants","description":"SETFCASREGIONRECOVERY contains public data and is available to all\nparticipants.\n\nSource\n\nSETFCASREGIONRECOVERY updates with each settlements run.\n\nVolume\n\nApproximately 10,000 rows per day","primary_keys":["BIDTYPE","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"FCAS Service Type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","288"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"RegionID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date of trading interval","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run no","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CUSTOMERREGIONENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer Region Energy Amount. NULL for Settlement dates post the IESS rule effective date","is_float":true},"GENERATORREGIONENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator Regional Energy Amount. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last Date record changed","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional ACE MWh value used for the FCAS Recovery. NULL for Settlement dates prior to the IESS rule effective date","examples":["-85.65730903","-759.11333956"],"is_float":true},"REGION_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional ASOE MWh value used for the FCAS Recovery. NULL for Settlement dates prior to the IESS rule effective date","examples":["54.03995331","723.84162922"],"is_float":true},"REGIONRECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NEM Regional Recovery Amount for FCAS","is_float":true},"REGIONRECOVERYAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Dollar Amount for the Region (RegionRecoveryAmountACE + RegionRecoveryAmountASOE). NULL for Settlement dates prior to the IESS rule effective date","examples":["0.00011575","6.70456488"],"is_float":true},"REGIONRECOVERYAMOUNT_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Dollar Amount for the Region recovered using the ACE MWh Values. NULL for Settlement dates prior to the IESS rule effective date","examples":["0.00011575","6.70456488"],"is_float":true},"REGIONRECOVERYAMOUNT_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Dollar Amount for the Region recovered using the ASOE MWh Values. NULL for Settlement dates prior to the IESS rule effective date","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETFCASREGIONRECOVERY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":46652615,"decompressed_size_all_time":37426972920},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SETGENDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1071"],"comment":"SETGENDATA shows meter settlement data for each generation meter point. A regional summary is also provided. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, SET_ENERGY_TRANSACTIONS and SET_ENERGY_GENSET_DETAIL replace SETGENDATA.","description":"SETGENDATA shows generator meter details, and SETGENDATA data is\nconfidential to the participant.\n\nBy comparison, the regional summary (SETGENDATAREGION) is public data.\n\nSource\n\nSETGENDATA updates with each Settlement run.","unused":true,"primary_keys":["DUID","GENSETID","PERIODID","REGIONID","SETTLEMENTDATE","STATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"GENSETID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Physical unit identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":64},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Station Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":64},"AENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Purchased Energy","is_float":true},"APC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Administered Price Compensation","is_float":true},"CPEEP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Connection Point Excess Energy Price = EEP * TLF","is_float":true},"CPRRP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Connection Point Price = RRP * TLF","is_float":true},"EEP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess Energy Price","is_float":true},"ENERGYCOST":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost of net energy $","is_float":true},"EXCESSENERGYCOST":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost of excess energy $","is_float":true},"EXPENERGY":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Energy (Generator Purchases) (MWh)","is_float":true},"EXPENERGYCOST":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Energy Cost ($)","is_float":true},"GENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Generated energy","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MDA":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Metering Data Agent"},"METERRUNNO":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Identifier of the meter run used in this settlement calculation","is_integer":true,"unsigned_int":true,"num_int_bits":32},"NETENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Generated energy","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RRP":{"sql_type":"NUMBER(20,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"SECONDARY_TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Secondary Transmission Loss Factor","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"APOWER":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"GPOWER":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RESC":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true},"RESP":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","unused":true,"is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETGENDATAREGION":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"GENDATAREGION","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1082"],"comment":"SETGENDATAREGION sets out summary settlement data for generation within the specified region. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, SET_ENERGY_REGION_SUMMARY replace SETGENDATAREGION.","description":"SETGENDATAREGION shows the regional summary. SETGENDATAREGION is public\ndata.\n\nSource\n\nSETGENDATAREGION updates with each Settlement run.","unused":true,"primary_keys":["PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(22,10)","pl_type":"pl.Float64","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","200"],"is_float":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2024/05/05 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(22,10)","pl_type":"pl.Float64","mandatory":true,"comment":"Settlement run no","examples":["12"],"is_float":true,"unsigned_int":true},"ENERGYCOST":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost of net energy $","examples":["-269.95147","1.59712","-18021.17474","167606.21924"],"is_float":true},"EXCESSENERGYCOST":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost of excess energy $","examples":["0"],"is_float":true},"EXPENERGY":{"sql_type":"NUMBER(27,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Energy (Generator Purchases)","examples":["-0.212487","-49.58294"],"is_float":true},"EXPENERGYCOST":{"sql_type":"NUMBER(27,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Energy Cost","examples":["-0.013823","2.251715","-7037.281457","2792.867124"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"current system date, to enable automatic replication","examples":["2024/11/25 07:51:48"],"parse_csv_as_string":true,"is_s_datetime":true},"NETENERGY":{"sql_type":"NUMBER(27,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net energy MW/hours","examples":["52.65059","636.02502"],"is_float":true},"AENERGY":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Purchased Energy - Not used in MMS Data Model","unused":true,"is_integer":true,"num_int_bits":128},"APOWER":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Not used in MMS Data Model","unused":true,"is_integer":true,"num_int_bits":128},"GENERGY":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Generated energy - Not used in MMS Data Model","unused":true,"is_integer":true,"num_int_bits":128},"GPOWER":{"sql_type":"NUMBER(22,0)","pl_type":"pl.Int128","mandatory":false,"comment":"Not used in MMS Data Model","unused":true,"is_integer":true,"num_int_bits":128}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_12/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETGENDATAREGION%23FILE01%23202412010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2024,"month":12},"has_missing_months":true,"compressed_size_per_month":1092863,"decompressed_size_all_time":2601485890},"visibility":"Public","trigger":"After each settlement run"},"SETGOVPAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1091"],"comment":"SETGOVPAYMENTshows specific payment details for Governor services by period.","description":"SETGOVPAYMENT is planned to become unused when Ancillary Services Review\nis implemented. For more details, see Change Notice 126 (1 Sep 2000),\nChange Notice 126a (18 Sep 2000) and any subsequent Change Notices with\nthe same number.\n\nSETGOVPAYMENT data is confidential to each participant.\n\nFrequency and source\n\nSETGOVPAYMENT updates with each settlement run.","unused":true,"primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"AS contract version no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEADBANDDOWN":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contracted dead band down","is_float":true},"DEADBANDUP":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contracted dead band up","is_float":true},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENABLING6LPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec lower enabling payment","is_float":true},"ENABLING6RPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec raise enabling payment","is_float":true},"ENABLING60LPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"60 sec lower enabling payment","is_float":true},"ENABLING60RPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"60 sec raise enabling payment","is_float":true},"L6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec lower response for 1% deviation in frequency (droop equation)","is_float":true},"L60":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"60 sec lower response for 1% deviation in frequency (droop equation)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LL6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec lower response limit equation","is_float":true},"LL60":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec lower response limit equation","is_float":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"re-offer offer version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"R6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec raise response for 1% deviation in frequency (droop equation)","is_float":true},"R60":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"60 sec raise response for 1% deviation in frequency (droop equation)","is_float":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RL6":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"6 sec raise response limit equation","is_float":true},"RL6SECLOWER":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contract enabling price - 6 sec lower","is_float":true},"RL6SECRAISE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contract enabling price - 6 sec raise","is_float":true},"RL60":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"60 sec raise response limit equation","is_float":true},"RL60SECLOWER":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contract enabling price - 60 sec lower","is_float":true},"RL60SECRAISE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"contract enabling price - 60 sec raise","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor of Unit","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETGOVRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1102"],"comment":"SETGOVRECOVERY shows reimbursements for the Governor Ancillary Services to be recovered from participants.","description":"SETGOVRECOVERY became unused when Ancillary Services Review was\nimplemented. For more details, see Change Notice 126.\n\nSETGOVRECOVERY data is confidential to each participant.\n\nSource\n\nSETGOVRECOVERY updates with each settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"is_categorical":true},"ENABLING6LPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment 6 Second Lower","is_float":true},"ENABLING6LRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 6 Second Lower","is_float":true},"ENABLING6LRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 6 Second Lower for Generator","is_float":true},"ENABLING6RPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment 6 Second Raise","is_float":true},"ENABLING6RRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 6 Second Raise","is_float":true},"ENABLING6RRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 6 Second Raise for Generator","is_float":true},"ENABLING60LPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment 60 Second Lower","is_float":true},"ENABLING60LRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 60 Second Lower","is_float":true},"ENABLING60LRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 60 Second Lower for Generator","is_float":true},"ENABLING60RPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment 60 Second Raise","is_float":true},"ENABLING60RRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 60 Second Raise","is_float":true},"ENABLING60RRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery 60 Second Raise for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand for Generator","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETINTERVENTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1111"],"comment":"SETINTERVENTION shows intervention settlement payment details by unit.","description":"SETINTERVENTION became unused when Ancillary Services Review was\nimplemented. For more details, see Change Notice 126.\n\nSETINTERVENTION data is confidential to each participant.\n\nSource\n\nSETINTERVENTION is unused; was updating when intervention occurred in a\nbilling run.","unused":true,"primary_keys":["DUID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Intervention Contract Identifier","is_categorical":true},"CONTRACTVERSION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Intervention Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERVENTIONPAYMENT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment to Generator for Intervention","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Regional Recovery Flag","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"visibility":"Private","trigger":"Not used"},"SETINTERVENTIONRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1120"],"comment":"SETINTERVENTIONRECOVERY shows intervention recovery details by participant.","description":"Status\n\nSETINTERVENTIONRECOVERY became unused when Ancillary Services Review was\nimplemented. For more details, see Change Notice 126.\n\nConfidential to participant\n\nSource\n\nUnused; was updating when intervention occurred in a billing run.","unused":true,"primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Intervention Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERVENTIONAMOUNT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Retailer Payment to Pool for Intervention","is_float":true},"INTERVENTIONPAYMENT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment to Generator for Intervention","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Regional Recovery Flag","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"TOTALDEMAND":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Demand of Region/Market","is_float":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand of Participant in Region/Market","unused":true,"is_float":true}},"visibility":"Private","trigger":"Not used"},"SETINTRAREGIONRESIDUES":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"INTRAREGIONRESIDUES","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#215"],"comment":"The Settlement Intra Region Residues Result.","description":"SETINTRAREGIONRESIDUES data is public to all participants.\n\nSource\n\nSETINTRAREGIONRESIDUES updates with each settlement run.\n\nNote\n\nThe relationship between the data columns for each key is expressed in\nthe following formula:\n\nEP + EC + (EXP \\* RRP) = IRSS","primary_keys":["PERIODID","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","200"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy Dollar Amount for the Region used in the calculation of IRSS (Intra Residue Amount). NULL for Settlement dates prior to the IESS rule effective date","examples":["-5.51892339","22.23585768","0","2005.96819264"],"is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy Dollar Amount for the Region used in the calculation of IRSS (Intra Residue Amount). NULL for Settlement dates prior to the IESS rule effective date","examples":["-24.19452681","6.19070026","0","59464.79340647"],"is_float":true},"EC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy purchased by customers. NULL for Settlement dates post the IESS rule effective date","is_float":true},"EP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy payments to generators. NULL for Settlement dates post the IESS rule effective date","is_float":true},"EXP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net import in MWh into the region calculated at the regional reference node (export is negative)","examples":["-0.08228","0.01493","0","35"],"is_float":true},"IRSS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Intra-regional surplus (a negative sign indicates surplus, and a positive sign indicates a deficiency)","examples":["-0.00901","0.01357","0","958.75189"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional price","examples":["-0.16","0.01","0","89"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETINTRAREGIONRESIDUES%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":9268438,"decompressed_size_all_time":4674125080},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SETIRAUCSURPLUS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRAUCSURPLUS","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#224"],"comment":"This view supports the Settlements Residue Auction, by holding the NSP participant allocations of IRSurplus arising as a result of the unsold units for a quarter.","description":"SETIRAUCSURPLUS data is confidential to the relevant participant.\n\nSource\n\nSETIRAUCSURPLUS updates with each settlement run.\n\nVolume\n\nSETIRAUCSURPLUS contains a maximum of 10 million records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contracted Interconnector identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTALLOCATION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Percentage allocated to participant","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount NSP is paid for Inter/intra-Regional surplus energy produced","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total value of surplus before allocation","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETIRFMRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1129"],"comment":"SETIRFMRECOVERY sets out reimbursements for Industrial Relations Force Majeure to be recovered from participants.","description":"SETIRFMRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETIRFMRECOVERY updates with each settlement run.","unused":true,"primary_keys":["IRFMID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"IRFMID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":true,"comment":"Industrial Relations Forced Majeure event number"},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant unique identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period ID","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"IRFMPAYMENT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Industrial Relations Forced Majeure payment amount in $.","is_float":true},"IRMFVERSION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Industrial Relations Forced Majeure event number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant demand","is_float":true},"TOTALTCD":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total non franchised load in Victoria.","is_float":true},"TOTALTFD":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total franchised load in Victoria.","is_float":true},"IRFMAMOUNT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Industrial Relations Forced Majeure event amount in $.","unused":true,"is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETIRNSPSURPLUS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRNSPSURPLUS","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#233"],"comment":"This view supports the Settlements Residue Auction, by showing the TNSP participant allocations of Interconnector Residue (IR) Surplus (i.e. derogated amounts) arising as a result of the sold units for a quarter.","description":"SETIRNSPSURPLUS data is confidential to the relevant participant.\n\nSource\n\nSETIRNSPSURPLUS updates with each settlement run.\n\nVolume\n\nSETIRNSPSURPLUS contains a maximum of 10 million records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"SRA Contract unique identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant unique identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTALLOCATION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Percentage of total surplus allocated to participant","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount NSP is paid for Inter/intra-Regional surplus energy produced by the participant","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total value of surplus","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETIRPARTSURPLUS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRPARTSURPLUS","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#242"],"comment":"This view supports the Settlements Residue Auction, holding the participant allocations of IRSurplus.","description":"SETIRPARTSURPLUS data is confidential to each participant.\n\nSource\n\nSETIRPARTSURPLUS updates with each settlement run.\n\nVolume\n\nSETIRPARTSURPLUS contains a maximum of 20 million records per year.","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Ancillary Service Contract","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"Nominated source region for Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of the Contracted Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant unique identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTRACTALLOCATION":{"sql_type":"NUMBER(8,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allocated percentage to participant","is_float":true},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time this record was last updated","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount NSP is paid for Inter/intra-Regional surplus energy produced","is_float":true},"TOTALSURPLUS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total value of surplus before allocation","is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETIRSURPLUS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRSURPLUS","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#251"],"comment":"SETIRSURPLUS records the interregional residue calculation for each interconnector and each side of the interconnector.","description":"SETIRSURPLUS data is public, so is available to all participants.\n\nSource\n\nSETIRSURPLUS updates once a day at 8am.\n\nNote\n\nMWFLOW and LOSSFACTOR are now both calculated as MWh (energy) values for\nthe half hour, and not MW (average demand) values. By way of\nclarification, the MWFLOW value is derived from half-hour revenue class\nmetering, adjusted by a fixed fraction of the LOSSFACTOR value. The\nLOSSFACTOR value is taken to be exactly half of the MWLOSSES value in\nthe TRADINGINTERCONNECT table.\n\nThe METEREDMWFLOW field in the TRADINGINTERCONNECT table contains\naveraged SCADA metering demand values available in “real time”, whereas\nthe MWFLOW field in the SETIRSURPLUS table contains settlement energy\nmetering values available only after a settlement run is posted.","primary_keys":["INTERCONNECTORID","PERIODID","REGIONID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","84"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Side of interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement date","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CSP_DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The CSP derogation amount applied as an adjustment to SRA","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"LOSSFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW losses along interconnector NOTE: This is not a loss factor, but a loss figure expressed in MWH","examples":["-0.00083","0.00167","0","11.11583"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Net flow at the regional node (MWh), including losses","examples":["-0.43895","0.357283","0","-38"],"is_float":true},"SURPLUSVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of surplus in $","examples":["-0.81316","0.90787","0","3115.15178"],"is_float":true},"UNADJUSTED_IRSR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SRA amount unadjusted by CSP","examples":["-0.81315917","0.90787332","0","3115.15177987"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETIRSURPLUS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":10294787,"decompressed_size_all_time":4792312380},"visibility":"Public","trigger":"Daily at 8 am"},"SETLOCALAREAENERGY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"LOCALAREAENERGY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#260"],"comment":"SETLOCALAREAENERGY shows the UFE, AGE and associated values for each local area and trading interval in a settlement run.","primary_keys":["LOCALAREAID","PERIODID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"columns":{"LOCALAREAID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the local area","examples":["NSW1","QLD1","SA1","TAS1"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement Trading Interval","examples":["1","288"],"is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement date of the settlement run","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number of the settlement run","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"ADME component of UFE for the local area in this trading interval, in MWh.","examples":["0"],"is_float":true},"ADMELA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The sum of all DME amounts for each Market Customer FRMP and TNI in the local area, in this trading interval.","examples":["0"],"is_float":true},"DDME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"DDME component of UFE for the local area in this trading interval, in MWh.","examples":["0"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date time for the record","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"TME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"TME component of UFE for the local area in this trading interval, in MWh.","examples":["0"],"is_float":true},"UFE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total unaccounted-for energy for the local area in this trading interval, in MWh","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETLOCALAREAENERGY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":21212769,"decompressed_size_all_time":4230418710},"visibility":"Public","trigger":"After each settlement run"},"SETLOCALAREATNI":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"LOCALAREATNI","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#266"],"comment":"SETLOCALAREATNI shows the list of TNIs constituent to a local area in a settlement run.","primary_keys":["LOCALAREAID","SETTLEMENTDATE","SETTLEMENTRUNNO","TNI"],"columns":{"LOCALAREAID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the local area","examples":["ACTEWAGL","AURORA","CITIPOWER","COUNTRYENERGY","ENERGEX","ENERGYAUST","ERGON1","INTEGRAL","NSWGRID","POWERCOR","QLDGRID","SAGRID","SNOWYGRID","TASGRID","TXU","UMPLP","UNITED","VICAGL","VICGRID"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement date of the settlement run","examples":["2026/04/12 00:00:00"],"parse_csv_as_string":true,"is_date":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number of the settlement run","examples":["10"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"TNI":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for a TNI constituent to the local area as at the settlement run","examples":["AAVT","AAXG","ABCN","ACTE","ACVC","AELK","AGCK","AGLM","AHRM","ALTM","AMS1","AQB1","AQB2","ARS1","ATDR","ATLP","AWDN","AWSA","NAL1","NALB","NALX","NANM","NAPP","NAR1","NBA2","NBAL","NBAY","NBB2","NBCO","NBER","NBES","NBFN","NBFS","NBG1","NBG3","NBGE","NBGN","NBHL","NBHX","NBK1","NBKB","NBKG","NBKH","NBKP","NBKW","NBL2","NBLW","NBM1","NBMP","NBOD","NBRG","NBSF","NBU2","NBUK","NBYW","NCAR","NCBS","NCDS","NCH1","NCHM","NCK4","NCKW","NCLG","NCLS","NCLW","NCLY","NCM2","NCMA","NCR1","NCRN","NCS1","NCSN","NCTB","NCW3","NCW8","NCWF","NDN7","NDNH","NDNS","NDNT","NDOR","NDT1","NDT2","NDTB","NDUN","NEP3","NEPS","NERB","NEV1","NEV2","NEV3","NFB2","NFBS","NFN2","NFNS","NFNY","NGAD","NGB1","NGF3","NGFT","NGG1","NGJP","NGLN","NGN2","NGNE","NGRF","NGSF","NGSQ","NGUR","NGUT","NGWF","NHBB","NHD2","NHLB","NHLD","NHLX","NHNC","NHUM","NHVN","NHYM","NING","NJDA","NKHN","NKL6","NKN1","NKNL","NKOG","NKPT","NKS2","NKS3","NLCV","NLD3","NLDB","NLDP","NLFD","NLMB","NLMD","NLP1","NLS2","NLTS","NMBK","NMBM","NMC1","NMC2","NMCV","NMDG","NMKV","NML1","NMLB","NMLD","NMLS","NMOL","NMOS","NMP6","NMPK","NMQP","NMQS","NMR1","NMR2","NMR4","NMRE","NMRK","NMRU","NMTP","NMTZ","NMU3","NMUN","NMUR","NMVN","NMWB","NMY1","NMYG","NNAM","NNB2","NNCP","NNEE","NNEW","NNRN","NNVL","NONF","NONO","NOR1","NOR6","NORB","NPG1","NPHL","NPHT","NPK6","NPKQ","NPKS","NPMA","NPMQ","NPO1","NQBB","NQBC","NQBY","NRAL","NRB2","NRBB","NRDP","NRGE","NRGV","NRKD","NRPK","NRSB","NRVA","NRVN","NRWR","NSAD","NSAP","NSE2","NSFS","NSHN","NSMB","NSN1","NSN2","NSPT","NSRD","NSTB","NSTU","NSW1","NSW2","NSWB","NSYS","NTA2","NTG3","NTMC","NTME","NTMG","NTNR","NTPR","NTR2","NTTF","NTU2","NTUX","NTWA","NURB","NURQ","NURR","NUT4","NUTS","NVP1","NVPP","NVYD","NWAV","NWD1","NWG2","NWG6","NWGG","NWGJ","NWGN","NWGS","NWL2","NWL8","NWLA","NWLN","NWLO","NWLS","NWLW","NWOW","NWR1","NWRK","NWST","NWW4","NWW5","NWW6","NWW7","NWYG","NYA3","NYS1","NYS6","QABM","QABR","QAFH","QAGW","QALC","QALG","QALH","QASF","QBBS","QBCB","QBCG","QBDA","QBDR","QBGH","QBIL","QBK2","QBKB","QBKS","QBLF","QBLG","QBLK","QBMH","QBNB","QBNN","QBOH","QBOL","QBRA","QBRE","QBRS","QBSS","QBSW","QBWH","QBWL","QCAB","QCAC","QCAR","QCAX","QCBB","QCBF","QCBL","QCBR","QCBS","QCBW","QCCK","QCDW","QCHA","QCHS","QCLA","QCLR","QCMD","QCND","QCOL","QCOP","QCOS","QCPG","QDGL","QDMR","QDMW","QDRG","QDYS","QEGD","QEGN","QELA","QEMS","QEMT","QGAR","QGBB","QGDA","QGLD","QGLH","QGLL","QGNG","QGNS","QGRE","QGRN","QGST","QGYR","QHAR","QINF","QING","QINV","QKAM","QKCK","QKYH","QLCH","QLCM","QLCS","QLGH","QLGL","QLIL","QLIS","QLLV","QMAR","QMGB","QMGL","QMKA","QMLN","QMND","QMPL","QMRA","QMRE","QMRG","QMRH","QMRL","QMRN","QMRR","QMRV","QMRX","QMRY","QMSP","QMSW","QMTM","QNEB","QNGY","QNLD","QNOR","QOKT","QOKY","QOON","QORH","QORS","QPAL","QPIV","QPKD","QPRO","QPWD","QQAH","QQNH","QRBS","QRGL","QRLD","QRLE","QRMA","QROC","QROG","QROS","QROW","QRPH","QRPN","QSLD","QSLS","QSPB","QSPN","QSPS","QSPT","QSTN","QSTX","QSUM","QSWE","QSYC","QTBC","QTBS","QTKM","QTKS","QTLL","QTMW","QTNN","QTNS","QTNT","QTRB","QTRL","QTRN","QTRS","QTUH","QTUL","QTVE","QTVS","QTYP","QTZS","QWAN","QWCB","QWDB","QWDE","QWDN","QWDR","QWDS","QWIP","QWIV","QWKM","QWLG","QWLM","QWLN","QWLS","QWOT","QWRE","QWSB","QWSH","QWSR","QWSS","QWST","QYAE","QYAG","QYAR","QYST","SACR","SANC","SANG","SARW","SBAC","SBAR","SBE1","SBEL","SBEM","SBER","SBHP","SBL1","SBLA","SBLW","SBPS","SBRK","SBUA","SBUN","SBUR","SBYW","SCGB","SCGW","SCLN","SCND","SCRK","SDAL","SDAN","SDAP","SDAV","SDAW","SDPS","SDRN","SETC","SHDW","SHPS","SHUM","SHVA","SJP1","SKAD","SKAN","SKET","SKLB","SKNC","SLBB","SLCS","SLFE","SLGW","SMA1","SMA2","SMA3","SMAB","SMAE","SMAG","SMAN","SMAY","SMBA","SMBK","SMBL","SMBS","SMDL","SMGA","SMGU","SMH1","SMH2","SMH3","SMLB","SMOK","SMPS","SMTL","SMTM","SMUP","SMVE","SMW1","SMW2","SMW3","SMW4","SNBN","SNEU","SNFD","SNPT","SNWB","SNWF","SOCP","SPAA","SPAR","SPEN","SPEW","SPGG","SPGW","SPL3","SPLN","SPMB","SPPR","SPPT","SPTL","SQPS","SRAB","SROB","SRSH","SSNN","SSNR","SSPN","SSPS","SSYP","STAL","STBB","STBS","STEM","STET","STPB","STPS","STSY","SWAT","SWGL","SWLE","SWMA","SWUD","SWYC","SYAD","TAL2","TAV2","TBB1","TBG1","TBU3","TBW2","TBYA","TBYB","TCE1","TCL1","TCO1","TCR2","TCS3","TDB2","TDE1","TDE2","TDG1","TDP2","TEB2","TEB3","TEL2","TFA1","TFI1","TFI2","TGH1","TGO1","TGO2","TGT1","TGT3","THA3","THM2","THR2","TJB1","TK13","TKE2","TKI2","TKR2","TLE1","TLF2","TLI1","TMA1","TMB1","TMB2","TMT2","TMY2","TNH2","TNN2","TNT2","TNT3","TNW2","TPA1","TPL2","TPM1","TPM2","TPM3","TQT2","TQT3","TQU2","TRA2","TRB2","TRCA","TRCB","TRI3","TRI4","TRK2","TSD2","TSH1","TSH3","TSL2","TSL3","TSM2","TSO2","TSR2","TST1","TST2","TSW1","TTA1","TTB2","TTE1","TTI1","TTR1","TTR2","TTU1","TTU2","TTV1","TUL2","TVN1","TVN2","TWA2","TWC1","TWV2","TWY2","VAPD","VARS","VART","VAT2","VATS","VBA2","VBAT","VBAW","VBBT","VBDL","VBE2","VBE6","VBGT","VBL1","VBL2","VBL3","VBL6","VBL7","VBT2","VBT6","VBTS","VCB2","VCB3","VCB5","VCBT","VCPT","VCWL","VDPS","VDPT","VELT","VEPS","VER2","VERT","VFB2","VFBT","VFVT","VGET","VGN2","VGN6","VGNS","VGNT","VGNW","VGP2","VGPT","VGT6","VGTW","VHGT","VHOG","VHOT","VHTS","VHUM","VHW2","VHY2","VJLA","VJLG","VKG2","VKG6","VKGB","VKGP","VKGS","VKMT","VKOT","VKT2","VKTS","VLY6","VLYP","VM04","VM05","VM0P","VMBT","VMLB","VMRT","VMT2","VMT6","VMT7","VMW6","VMWT","VNPS","VPLT","VPR2","VPR3","VPRT","VRC2","VRC6","VRCA","VRCS","VRT2","VRT6","VRT7","VRW2","VRW3","VRW6","VRW7","VSHS","VSHT","VSM6","VSM7","VSMT","VSOM","VSV2","VSVT","VT14","VTB2","VTBL","VTBT","VTG2","VTG3","VTG6","VTGT","VTR1","VTR3","VTRT","VTS2","VTS3","VTS4","VTST","VTT2","VTTS","VWBT","VWEA","VWES","VWET","VWKP","VWM2","VWM6","VWM7","VWO2","VWO6","VYP1","VYP2","VYP3"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date time for the record","examples":["2026/08/27 07:25:50"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SETLOCALAREATNI%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":554617,"decompressed_size_all_time":105231760},"visibility":"Public","trigger":"After each settlement run"},"SETLSHEDPAYMENT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"LSHEDPAYMENT","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#272"],"comment":"SETLSHEDPAYMENT shows specific payment details for load shed services by period. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"SETLSHEDPAYMENT data is confidential to the relevant participant.\n\nSource\n\nSETLSHEDPAYMENT updates with each settlement run.","primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"AS Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ALS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Amount of load shed","is_float":true},"AVAILABILITYPAYMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount for the Load Shed Availability service","is_float":true},"CCPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"CONSTRAINEDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared MW of unit at time of load shed usage","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"AS Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"FINALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Final demand of unit at time of load shed usage","is_float":true},"INITIALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Initial demand of unit at time of load shed usage","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LSCR":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"Load Shed Control Range","is_integer":true,"num_int_bits":16},"LSEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Enabling Payment","is_float":true},"LSEPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Enabling Price","is_float":true},"MCPPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Compensation Price","is_float":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"UNCONSTRAINEDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained MW of unit at time of load shed usage","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETLSHEDRECOVERY":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#283"],"comment":"SETLSHEDRECOVERY shows reimbursements for Load shed Ancillary Services to be recovered from participants. (Data no longer created for Settlement Days from 01/07/2012)","description":"SETLSHEDRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETLSHEDRECOVERY updates with each settlement run.\n\nNote\n\nOnly the payment fields (LSEPAYMENT and CCPAYMENT) are on a regional\nbasis. All other demand and recovery fields are on NEM basis rather than\na regional basis.","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AVAILABILITYRECOVERY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Load Shed Availability service attributable to customer connection points","is_float":true},"AVAILABILITYRECOVERY_GEN":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Load Shed Availability service attributable to generator connection points","is_float":true},"CCPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"CCRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery","is_float":true},"CCRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery for Generator","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Contract Identifier for reserve, intervention, settlement and ancillary service contracts. Contracts are coded by type and unit.","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LSEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Enabling Payment","is_float":true},"LSERECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Enabling Recovery","is_float":true},"LSERECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Load Shed Enabling Recovery for Generator","is_float":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Participant NEM Demand","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Participant NEM Demand for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total NEM Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total NEM Demand for Generator","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETLULOADPAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1138"],"comment":"SETLULOADPAYMENT shows specific payment details for rapid unit load services by period.","description":"SETLULOADPAYMENT became unused when Ancillary Services Review was\nimplemented. For more details, see Change Notice 126.\n\nSETLULOADPAYMENT data is confidential to each participant.\n\nSource\n\nSETLULOADPAYMENT is unused; was updated with each settlement run.","unused":true,"primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"AS Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACR":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Dispatch target","is_float":true},"BLOCKSIZE":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Indicates how much of the unit at one given time is available for the ancillary service.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CCPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"COMPENSATIONPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EBP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Eligible Bid Price","is_float":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"ENABLINGPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Price","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"UNITEXCESSGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess Generation","is_float":true},"UNITOUTPUT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Unit output.","is_float":true},"USAGEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Payment","is_float":true},"USAGEPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Price","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETLULOADRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1149"],"comment":"SETLULOADRECOVERY shows reimbursements for rapid-unit-load Ancillary Services to be recovered from participants.","description":"SETLULOADRECOVERY became unused when Ancillary Services Review was\nimplemented. For more details, see Change Notice 126.\n\nSETLULOADRECOVERY data is confidential to each participant.\n\nSource\n\nSETLULOADRECOVERY is unused; was updated with each settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATIONPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"COMPENSATIONRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery","is_float":true},"COMPENSATIONRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery for Generator","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"AS Contract ID","is_categorical":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"ENABLINGRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery","is_float":true},"ENABLINGRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand for Generator","is_float":true},"USAGEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Payment","is_float":true},"USAGERECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Recovery","is_float":true},"USAGERECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Recovery for Generator","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETLUNLOADPAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1158"],"comment":"SETLUNLOADPAYMENT shows specific payment details for rapid unit unload service.","description":"SETLUNLOADPAYMENT data is confidential to the relevant participant.\n\nSource\n\nSETLUNLOADPAYMENT updates with each settlement run.","unused":true,"primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Ancillary Services contract identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CCPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation cap","is_float":true},"CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared MW of Unit in Dispatch, Predispatch or Trading period.","is_float":true},"COMPENSATIONPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation payment","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Contract version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONTROLRANGE":{"sql_type":"NUMBER(4,0)","pl_type":"pl.Int16","mandatory":false,"comment":"The MW output achieved in 5 minutes from startup and is what payment is based on.","is_integer":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EBP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Eligible bid price","is_float":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling payment","is_float":true},"ENABLINGPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling price","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"UNCONSTRAINEDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW output the generator would have been running at had it not been constrained up to provide unit unloading","is_float":true},"USAGEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Payment","is_float":true},"USAGEPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Price","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETLUNLOADRECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1169"],"comment":"SETLUNLOADRECOVERY shows reimbursements for rapid unit unloading Ancillary Services to be recovered from participants.","description":"SETLUNLOADRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETLUNLOADRECOVERY updates with each settlement run.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading Interval","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATIONPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"COMPENSATIONRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery","is_float":true},"COMPENSATIONRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery for Generator","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"AS Contract","is_categorical":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"ENABLINGRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery","is_float":true},"ENABLINGRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Regional Demand for Generator","is_float":true},"USAGEPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Payment","is_float":true},"USAGERECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Recovery","is_float":true},"USAGERECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Usage Recovery for Generator","is_float":true}},"visibility":"Private","trigger":"Each settlement run"},"SETMARKETFEES":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"MARKETFEES","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#292"],"comment":"SETMARKETFEES shows payments for market fees for each settlement date.","description":"SETMARKETFEES is confidential data.\n\nSource\n\nSETMARKETFEES updates with each settlement run.","primary_keys":["MARKETFEEID","PARTICIPANTCATEGORYID","PARTICIPANTID","PERIODID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"MARKETFEEID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Market fee identifier (e.g. V_EST)","is_categorical":true},"PARTICIPANTCATEGORYID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant category that the market fee recovery pertains to. Corresponds to the PARTICIPANTCATEGORYID column of the PARTICIPANT_BANDFEE_CATEGORYALLOC_C_V view for BAND$ type fees, or to the MARKETFEETYPE column of the MARKETFEE_P_V view for all other fee types.","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy amount for variable fees","is_float":true},"FEERATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The rate applied to this fee for the participant at the settlement date","is_float":true},"FEEUNITS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The number of units applicable to this fee for the participant, in the trading interval.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MARKETFEEVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Fee charge","is_float":true},"METER_SUBTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"ACE\", \"ASOE\", \"ALL\"])","mandatory":false,"comment":"The Meter Sub Type values are ACE, ASOE or ALL. ACE represent ACE_MWH value or ASOE represent ASOE_MWH value and ALL represent sum of ACE_MWh and ASOE_MWh","examples":null,"enums":["ACE","ASOE","ALL"]},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Energy Type for the Market Fees Calculation. E.g of Meter Types are CUSTOMER, GENERATOR, NREG, BDU etc. If Meter Type is mentioned as ALL then all the Meter Types for that Participant Category will be used in the Fee calculation","is_categorical":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SETREALLOCATIONS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"REALLOCATIONS","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#301"],"comment":"SETREALLOCATIONS shows the trading interval value of reallocations processed, for those participants whose reallocation submissions have been accepted by AEMO.","description":"SETREALLOCATIONS data is confidential to participants party to the\nreallocation.\n\nSource\n\nSETREALLOCATIONS updates by the posting of a billing run.\n\nVolume\n\nGenerally, there are approximately 550 records inserted per week.","primary_keys":["PARTICIPANTID","PERIODID","REALLOCATIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REALLOCATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Reallocation contract identifier"},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run no","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Calendar Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"ENERGY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy in MWh if reallocation agreement type is MWh","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REALLOCATIONVALUE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reallocation value in $","is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true}},"visibility":"Private","trigger":"Updates by the posting of a billing run"},"SETRESERVERECOVERY":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#310"],"comment":"SETRESERVERECOVERY shows reserve recovery details.","description":"SETRESERVERECOVERY is unused.\n\nSource\n\nUnused; was updated when reserve recovery occurred in a billing run.","primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand of Participant in Region/Market","is_float":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Regional Recovery Flag","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RESERVEAMOUNT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment owed by Retailer to pool for Reserve Trader Contract","is_float":true},"RESERVEPAYMENT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment made to generator for Reserve Trader Contract","is_float":true},"SPOTPAYMENT":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cap difference for generator","is_float":true},"TOTALDEMAND":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Demand of Region/Market","is_float":true}},"visibility":"Private","trigger":"When reserve recovery occurred in a billing run"},"SETRESERVETRADER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1178"],"comment":"SETRESERVETRADER shows reserve trader details.","description":"SETRESERVETRADER data is confidential to the relevant participant.\n\nSource\n\nSETRESERVETRADER updates when reserve trading occurs in a billing run,\nsuch as during an Administered Price Cap event. SETRESERVETRADER is\nempty until such an event occurs.","unused":true,"primary_keys":["DUID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit ID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CAPDIFFERENCE":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Spot payment applicable to the capacity above the enabling threshold","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Reserve Trader Contract Identifier","is_categorical":true},"CONTRACTVERSION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Reserve Trader Contract Version","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CPA":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Availability Payment","is_float":true},"CPE":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Enabling Payment","is_float":true},"CPTOTAL":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Payment for Contract","is_float":true},"CPU":{"sql_type":"NUMBER(12,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Contract Usage Payment","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique participant identifier","is_categorical":true},"RCF":{"sql_type":"CHAR(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"Reserve Recovery Flag","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"UNITAVAIL":{"sql_type":"NUMBER(6,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Offered Availability of Unit","is_float":true}},"visibility":"Private","trigger":"When a reserve trading occurs in a billing run"},"SETRESTARTPAYMENT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"RESTARTPAYMENT","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#319"],"comment":"SETRESTARTPAYMENT shows specific payment details for System Restart services by period.","description":"SETRESTARTPAYMENT data is confidential to the relevant participant.\n\nSource\n\nSETRESTARTPAYMENT updates with each settlement run.","primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"],["PARTICIPANTID"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AVAFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Availability Flag","is_boolean":true},"AVAILABILITYPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Payment","is_float":true},"AVAILABILITYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Price","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ENABLINGPAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The enabling payment made for system restart in this half-hour interval","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RESTARTTYPE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"System Restart Type (0 = FRC, 1 = GRC, 2 = TTH)","is_integer":true,"num_int_bits":8},"TCF":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Service Test Flag","is_boolean":true}},"visibility":"Private","trigger":"After each settlement run"},"SETRESTARTRECOVERY":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#330"],"comment":"SETRESTARTRECOVERY shows reimbursements for system restart Ancillary Services to be recovered from participants. (Data no longer created for Settlement Days from 01/07/2012)","description":"SETRESTARTRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETRESTARTRECOVERY updates with each settlement run.","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AVAILABILITYPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Payment","is_float":true},"AVAILABILITYRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Recovery","is_float":true},"AVAILABILITYRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Recovery for Generator","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Contract Identifier","is_categorical":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The enabling payment made for system restart in this half-hour interval","is_float":true},"ENABLINGRECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The enabling recovery amount for system restart in this half-hour interval attributable to customer activity","is_float":true},"ENABLINGRECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The enabling recovery amount for system restart in this half-hour interval attributable to generator activity","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Demand in Region for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"NEM Demand (NB sum of ALL Regions)","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all generation including SGA generation across all regions of the NEM and floored to zero","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETRPOWERPAYMENT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"RPOWERPAYMENT","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#339"],"comment":"SETRPOWERPAYMENT shows specific payment details for Reactive power services by period. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","description":"SETRPOWERPAYMENT data is confidential to the relevant participant.\n\nSource\n\nSETRPOWERPAYMENT updates with each settlement run.","primary_keys":["CONTRACTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"AS Contract Identifier","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AVAFLAG":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Availability Flag","is_boolean":true},"AVAILABILITYPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Payment","is_float":true},"AVAILABILITYPAYMENT_REBATE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The rebate amount if MegaVar (MVAr) is below the threshold.","is_float":true},"BLOCKSIZE":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Block size of unit","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CCPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Payment","is_float":true},"CCPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Cap","is_float":true},"CLEAREDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared MW of unit","is_float":true},"CONTRACTVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"AS Contract Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EBP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Eligible Bid Price","is_float":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MTA":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Absorption Capability (MVAr)","is_float":true},"MTG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Reactive Power Generation Capability (MVAr)","is_float":true},"MVARAPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability price per MVAr of RP absorption capability","is_float":true},"MVAREPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Price","is_float":true},"MVARGPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability price per MVAr of RP generation capability","is_float":true},"OFFERDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Re-offer offer date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OFFERVERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Re-Offer Version No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"SYNCCOMPENSATION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Sync Compensation Flag","is_boolean":true},"TLF":{"sql_type":"NUMBER(7,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"UNCONSTRAINEDMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained MW of unit","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETRPOWERRECOVERY":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#348"],"comment":"SETRPOWERRECOVERY shows reimbursements for Reactive Power Ancillary Services to be recovered from participants. (Data no longer created for Settlement Days from 01/07/2012)","description":"SETRPOWERRECOVERY data is confidential to the relevant participant.\n\nSource\n\nSETRPOWERRECOVERY updates with each settlement run.\n\nNote\n\nOnly the payment fields (AVAILABILITYPAYMENT, ENABLINGPAYMENT and\nCCPAYMENT) are on a regional basis. All other demand and recovery fields\nare on NEM basis rather than a regional basis.","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant to pay recovery","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AVAILABILITYPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Payment","is_float":true},"AVAILABILITYRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Recovery","is_float":true},"AVAILABILITYRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Availability Recovery for Generator","is_float":true},"CCRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery","is_float":true},"CCRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation Recovery for Generator","is_float":true},"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"AS Contract Identifier","is_categorical":true},"ENABLINGPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Payment","is_float":true},"ENABLINGRECOVERY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery","is_float":true},"ENABLINGRECOVERY_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Enabling Recovery for Generator","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Participant NEM Demand","is_float":true},"PARTICIPANTDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Participant NEM Demand for Generator","is_float":true},"REGIONDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total NEM Demand","is_float":true},"REGIONDEMAND_GEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total NEM Demand for Generator","is_float":true},"CCPAYMENT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation payment","unused":true,"is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SETSMALLGENDATA":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1187"],"comment":"Publishes metering data and associated settlement values for with registered Small Generator Aggregator participants connection points. The table is populated for participants using Data Model 5.2. For participants using Data Model 5.3 or higher, SET_ENERGY_TRANSACTIONS and SET_ENERGY_GENSET_DETAIL replace SETSMALLGENDATA.","unused":true,"primary_keys":["CONNECTIONPOINTID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Transmission Node Identifier (TNI)","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number of the record for the settlement date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXPENERGYCOST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Export Energy Cost ($)","is_float":true},"EXPORTENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The export direction value for the meter read (MWh)","is_float":true},"IMPORTENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The import direction value for the meter read (MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time the record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Reference Price","is_float":true},"TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss Factor","is_float":true},"IMPENERGYCOST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Import Energy Cost ($)","unused":true,"is_float":true}},"visibility":"Private","trigger":"When there is a change to the metering data and associated settlement values to a participant's registered Small Generator Aggregator"},"SETVICBOUNDARYENERGY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1193"],"comment":"SETVICBOUNDARYENERGY is as requested by Participants for the settlement of Victorian Vesting contracts.","description":"SETVICBOUNDARYENERGY data is confidential to the relevant participants.\n\nSource\n\nSETVICBOUNDARYENERGY is populated by the posting of a billing run.\n\nVolume\n\nGenerally there are approximately 550 records inserted per week.","unused":true,"primary_keys":["PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement and date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BOUNDARYENERGY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Interval energy purchases in Victoria when host distributor = Pool (in MWh)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"The posting of a billing run"},"SETVICENERGYFIGURES":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1202"],"comment":"SETVICENERGYFIGURES is used in settlement of Victorian Vesting contracts.","description":"SETVICENERGYFIGURES data is public, so is available to all participants.\n\nSource\n\nSETVICENERGYFIGURES updates daily, with settlements.","unused":true,"primary_keys":["PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MLF":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal loss factor","is_float":true},"TLR":{"sql_type":"NUMBER(15,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission loss factor","is_float":true},"TOTALGENOUTPUT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total generator output","is_float":true},"TOTALPCSD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total participant demand","is_float":true}},"visibility":"Public","trigger":"Daily with settlements"},"SETVICENERGYFLOW":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1211"],"comment":"SETVICENERGYFLOW is used in settlement of Victorian Vesting contracts.","description":"SETVICENERGYFLOW data is public, so is available to all participants.\n\nSource\n\nSETVICENERGYFLOW updates daily, with settlements","unused":true,"primary_keys":["PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlement period","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NETFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Net metered energy flowing across the V-SN and V-SA interconnectors","is_float":true}},"visibility":"Public","trigger":"Daily with settlements"},"SET_ANCILLARY_SUMMARY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"ANCILLARY_SUMMARY","VERSION":5}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#22"],"comment":"SET_ANCILLARY_SUMMARY summarises payments for all Ancillary Services to participants on the basis of regions and trading intervals.","description":"SET_ANCILLARY_SUMMARY data is available to all participants.\n\nVolume\n\nApproximately 30, 000 per week.","primary_keys":["PAYMENTTYPE","PERIODID","REGIONID","SERVICE","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PAYMENTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Payment type identifier (e.g. COMPENSATION)","examples":["AVAILABILITY"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval","examples":["1","288"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Ancillary service identifier (e.g. REACTIVE_POWER)","examples":["RESTART"],"is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENTAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NEM ancillary summary regional payment amount ($)","examples":["30.63333333","128.36666666"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_ANCILLARY_SUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":2025729,"decompressed_size_all_time":1001622610},"visibility":"Public","trigger":"After posting of a billing run"},"SET_APC_COMPENSATION":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#10"],"comment":"APC Compensation payment amounts in the Settlements timeframe","primary_keys":["APEVENTID","CLAIMID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"columns":{"APEVENTID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Id","is_integer":true,"num_int_bits":32},"CLAIMID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Claim Id","is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement run date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"COMPENSATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Compensation amount for the event claim in this interval","is_float":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to SETAPCCOMPENSATION","category":"related_tables"}],"trigger":"After posting of a billing run"},"SET_APC_RECOVERY":{"package":"SETTLEMENT_DATA","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#16"],"comment":"APC Compensation recovery amounts in the Settlements timeframe","primary_keys":["APEVENTID","CLAIMID","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"APEVENTID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Id","is_integer":true,"num_int_bits":32},"CLAIMID":{"sql_type":"NUMBER(6)","pl_type":"pl.Int32","mandatory":true,"comment":"AP Event Claim Id","is_integer":true,"num_int_bits":32},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region id for the recovery amount","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement run date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount in the region attributable to the participant for the event claim in this interval","is_float":true},"REGION_RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Recovery amount in the region for the event claim in this interval","is_float":true}},"visibility":"Private","warnings":[{"msg":"This is a different table to SETAPCRECOVERY","category":"related_tables"}],"trigger":"After posting of a billing run"},"SET_CSP_DEROGATION_AMOUNT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#932"],"comment":"A settlement table for the publication of Snowy CSP derogation amounts.","description":"Source\n\nSettlements data process is populated at the posting of a billing run in\nwhich it is included.\n\nVolume\n\nEstimated number of rows is 13440 for a based on the 35 settlement days\nposted per week. Note this data would only be delivered to the\nparticipant receiving payments from the derogation.","unused":true,"primary_keys":["AMOUNT_ID","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"AMOUNT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"TA1\", \"TA2\", \"TA3\", \"TA4\", \"TA5\", \"TA6\", \"TA8\"])","mandatory":true,"comment":"Amount identifier represented as a string, from \"TA1\" through to \"TA6\" (or \"TA8\" for a LYMMCO derogation result)","examples":null,"enums":["TA1","TA2","TA3","TA4","TA5","TA6","TA8"]},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant allocated the payment amount for the derogation.","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DEROGATION_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Derogation amount associated with the amount identifier","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"At the posting of a billing run"},"SET_CSP_SUPPORTDATA_CONSTRAINT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#941"],"comment":"A settlements table for the publication of support data for the Snowy CSP derogation amounts. This table publishes the constraint-level information for each five minute interval in the settlement run","description":"Source\n\nSettlements data process is populated at the posting of a billing run in\nwhich it is included.\n\nVolume\n\nEstimated number of rows is an average of 1000 per week based on the 35\nsettlement days posted per week.","unused":true,"primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch interval identifier","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements trading interval identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ABS_X":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Equal to RHS if the constraint direction is SOUTH, otherwise zero","is_float":true},"ABS_Y":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Equal to RHS if the constraint direction is NORTH, otherwise zero","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERTUMUT_CSPA_COEFF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"LOWERTUMUT_FACTOR x MARGINALVALUE","is_float":true},"LOWERTUMUT_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Value of the Lower Tumut left-hand term of the constraint","is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Marginal value of the constraint","is_float":true},"RHS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"RHS value of the constraint","is_float":true},"UPPERTUMUT_CSPA_COEFF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"UPPERTUMUT_FACTOR x MARGINALVALUE","is_float":true},"UPPERTUMUT_FACTOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Value of the Upper Tumut left hand term of the constraint","is_float":true}},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"At the posting of a billing run"},"SET_CSP_SUPPORTDATA_ENERGYDIFF":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#950"],"comment":"A settlements table for the publication of support data for the Snowy CSP derogation amounts. This table publishes energy differential information for each half-hour interval in the settlement run","description":"THIS TABLE WILL BE DISCONTINUED AS PART OF THE END OF YEAR 2009 MMS\nRELEASESource\n\nSettlements data process is populated at the posting of a billing run in\nwhich it is included.\n\nVolume\n\nEstimated number of rows is an average of 1000 per week based on the 35\nsettlement days posted per week.","unused":true,"primary_keys":["PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Period identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"EVA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy value adjustment for northward flows in the half-hour interval","is_float":true},"FLOW_DIRECTION":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"NORTH\", \"SOUTH\"])","mandatory":false,"comment":"Indicates the determined direction of flow in the half hour. Will be either “”NORTH” or “SOUTH”","examples":null,"enums":["NORTH","SOUTH"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERTUMUT_AGE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy output of the Lower Tumut unit in the half hour interval","is_float":true},"LOWERTUMUT_EVDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Tumut Energy Value Differential for the half hour interval","is_float":true},"LOWERTUMUT_SPDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Tumut Substitute Price for the half hour interval","is_float":true},"TOTAL_X":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all \"ABS_X\" values in the half hour","is_float":true},"TOTAL_Y":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all \"ABS_Y\" values in the half hour","is_float":true},"UPPERTUMUT_AGE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy output of the Upper Tumut unit in the half hour interval","is_float":true},"UPPERTUMUT_EVDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Upper Tumut Energy Value Differential for the half hour interval","is_float":true},"UPPERTUMUT_SPDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Upper Tumut Substitute Price for the half hour interval","is_float":true}},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}]},"SET_CSP_SUPPORTDATA_SUBPRICE":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#959"],"comment":"A settlements table for the publication of support data for the Snowy CSP derogation amounts. This table publishes substitution price information for each five minute interval in the settlement run","description":"Source\n\nSettlements data process is populated at the posting of a billing run in\nwhich it is included.\n\nVolume\n\nEstimated number of rows is an average of 1000 per week based on the 35\nsettlement days posted per week.","unused":true,"primary_keys":["INTERVAL_DATETIME","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch interval identifier","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERVAL_ABS_X":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all ABS_X values for binding CSP constraints in the dispatch interval","is_float":true},"INTERVAL_ABS_Y":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of all ABS_Y values for binding CSP constraints in the dispatch interval","is_float":true},"IS_CSP_INTERVAL":{"sql_type":"NUMBER(1)","pl_type":"pl.Boolean","mandatory":false,"comment":"A flag to indicate whether a binding CSP constraint was present in the dispatch interval. A value of 1 indicates that CSP processing occurred due to a binding CSP constraint, while a value of 0 indicates that no binding CSP constraints were present in this interval","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERTUMUT_CSPA_COEFF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of CSPAxCOEFF for all constraints and Lower Tumut left-hand terms","is_float":true},"LOWERTUMUT_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The dispatch price at the Lower Tumut node","is_float":true},"LOWERTUMUT_SPDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute Price for Lower Tumut","is_float":true},"LOWERTUMUT_SPDP_UNCAPPED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"LOWERTUMUT_SPDP before VOLL or MPF capping is applied","is_float":true},"LOWERTUMUT_TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission loss factor of the Lower Tumut unit","is_float":true},"PERIODID":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":false,"comment":"Period identifier","is_integer":true,"num_int_bits":16},"RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"SNOWY1 RRP for the dispatch interval","is_float":true},"UPPERTUMUT_CSPA_COEFF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of CSPAxCOEFF for all constraints and Upper Tumut left-hand terms","is_float":true},"UPPERTUMUT_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The dispatch price at the Upper Tumut node","is_float":true},"UPPERTUMUT_SPDP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute Price for Upper Tumut","is_float":true},"UPPERTUMUT_SPDP_UNCAPPED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"UPPERTUMUT_SPDP before VOLL or MPF capping is applied","is_float":true},"UPPERTUMUT_TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission Loss factor of the Upper Tumut unit","is_float":true}},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"At the posting of a billing run"},"SET_ENERGY_GENSET_DETAIL":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"ENERGY_GENSET_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#31"],"comment":"The Settlement Energy Genset report contains the Energy Transactions data for each generation meter point. This report is produced only for Settlement Date post the IESS rule effective date.","primary_keys":["DUID","GENSETID","PERIODID","SETTLEMENTDATE","STATIONID","VERSIONNO"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The DUID for the meter associated with the GensetId","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"GENSETID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The GensetId for the Meter Id received","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"STATIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The StationId identifier associated with the GensetId","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy Dollar Amount","is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy for the Meter Id (CE_MWh + UFEA)","is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy Dollar Amount","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy for the Meter Id.","is_float":true},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy for the Meter Id . Energy received in the meter reads (DLF Adjusted)","is_float":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Connection Point associated with the DUID","is_categorical":true},"DME_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The DME MWh value that is used to calculate the UFEA Allocation Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed Date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"METERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Meter ID Identifier (NMI)","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Participant Id Identifier","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The Region Id for the Connection Point associated with the DUID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional Reference Price for the Settlement Period","is_float":true},"TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Transmission Loss Factor applied to the Connection Point Id. TLF is calculated based on the Net Flow at the TNI.","is_float":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Amount for the Meter Id (ACE_Amount + ASOE_Amount)","is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total MWh for the Meter Id (ACE_MWh + ASOE_MWh)","is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The UFEA allocation amount applied to the Meter Data","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_ENERGY_REGION_SUMMARY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"ENERGY_REGION_SUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#37"],"comment":"The Settlement Energy Region Summary report contains the Energy Transactions Summary for all the NEM regions. This report is produced only for Settlement Date post the IESS rule effective date.","primary_keys":["PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","examples":["1","200"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The NEM Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy Amount for the Region Id","examples":["-4.15655294","5.38296381","0","6095.24358502"],"is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy summary for the Region Id","examples":["-82.1084747","-738.44271153"],"is_float":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy Amount for the Region Id","examples":["-5.87693386","4.57427436","0","57025.50671109"],"is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy summary for the Region Id","examples":["58.6799256","757.31204239"],"is_float":true},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy summary for the Region Id","examples":["-82.1084747","-738.44271153"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed Date time of the record","examples":["2026/09/03 01:17:51"],"parse_csv_as_string":true,"is_s_datetime":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Dollar Amount summary for the Region Id","examples":["-0.02594907","0.14167824","0","5927.18933553"],"is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Energy summary for the Region Id","examples":["-0.19436928","0.24478341","-78.35304719","103.98065246"],"is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The UFEA Energy summary for the Region Id","examples":["0"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_ENERGY_REGION_SUMMARY%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":18076084,"decompressed_size_all_time":43213231290},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_ENERGY_TRANSACTIONS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"ENERGY_TRANSACTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#49"],"comment":"The Settlement Energy Transactions report contains the Energy Transactions data for all the Participants based on their ACE and ASOE at each customer and generator Connection Point ID. This table is populated The Settlement Energy Transactions report contains the Energy Transactions data for all the Participants based on their ACE and ASOE at each customer and generator Connection Point ID. This table is populated only if Settlement Date is post the IESS rule effective date.","primary_keys":["CONNECTIONPOINTID","METER_TYPE","PARTICIPANTID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Connection Point associated with the Energy Transaction reads.","is_categorical":true},"METER_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The type of meter reads received. Eg Customer, Generator, BDU, NREG etc.","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The dollar amount for Adjusted Consumed Energy MWh (ACE_MWh * TLF * RRP)","is_float":true},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Consumed Energy MWh ( CE_MWh + UFEA) for the ConnectionPointId","is_float":true},"AGGREGATE_READ_FLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"The Flag is 1 if the meter data source is from Aggregate Reads Meter Data, Else 0","is_boolean":true},"ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The dollar amount for Adjusted Sent Out Energy MWh (ASOE_MWh * TLF * RRP)","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Sent Out Energy for the ConnectionPointId . Energy received in the meter reads adjusted by DLF.","is_float":true},"CASE_ID":{"sql_type":"NUMBER(10,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"The Metering Case ID","is_integer":true,"unsigned_int":true,"num_int_bits":64},"CE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Consumed Energy . Energy received in the meter reads (DLF Adjusted)","is_float":true},"DME_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The DME MWh (Distribution Connected) that is used in the UFEA Calculation.","is_float":true},"INDIVIDUAL_READ_FLAG":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"The Flag is 1 if the meter data source is from Individual Reads Meter Data, Else 0","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed Date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The NEM Region Id Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional Reference Price for the Region","is_float":true},"TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Transmission Loss Factor applied to the Connection Point Id. TLF is calculated based on the Net Flow at the TNI.","is_float":true},"TOTAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total Dollar Value for the Participant. ACE_Amount + ASOE_Amount","is_float":true},"TOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total MWh Value for the Participant. ACE_MWh + ASOE_MWh","is_float":true},"UFEA_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The UFE Allocation Amount applied to the Participant","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_ENERGY_TRAN_SAPS":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"ENERGY_TRAN_SAPS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#43"],"comment":"The table shows the Transaction Details for the SAPS Connection Points. The table contains both the MSRPs and Retailers data","primary_keys":["PARTICIPANTID","PERIODID","SETTLEMENTDATE","TNI","VERSIONNO"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant ID for the SAPS TNI","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period Id identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The SAPS Connection Point Identifier","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CONSUMED_ENERGY_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Cost of the Consumed Energy","is_float":true},"CONSUMED_ENERGY_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy MWh Consumed for that TNI for the Participant ID","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed Date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The SAPS Region ID","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SAPS_RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The SAPS Settlement Price for the Region","is_float":true},"SENTOUT_ENERGY_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Cost of the Sent Out Energy","is_float":true},"SENTOUT_ENERGY_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Energy MWh Sent Out for the TNI for the Participant Id","is_float":true}},"visibility":"Private","trigger":"After posting of a billing run"},"SET_FCAS_CLAWBACK_REQ":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_CLAWBACK_REQ","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#55"],"comment":"This report contains the Interval Datetime affected by the Clawback Run and the adjusted FCAS requirement Costs.","primary_keys":["BIDTYPE","CONSTRAINTID","INTERVAL_DATETIME","REGIONID","RUNNO"],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"The FCAS Service - DUID offered type","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Constraint ID used in the FCAS Requirements.","examples":["F_MAIN+APD_TL_L5","F_MAIN+APD_TL_L6","F_MAIN+APD_TL_L60","F_MAIN+BIP_ML_L6","F_MAIN+LREG_0210","F_MAIN+NIL_MG_R1","F_MAIN+NIL_MG_R5","F_MAIN+NIL_MG_R6","F_MAIN+NIL_MG_R60","F_MAIN+RREG_0220","F_S++TBTU_L5","F_S++TBTU_L6","F_S++TBTU_R5","F_S++TBTU_R6","F_T+NIL_ML_RECL_L5"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Interval Datetime for which a the Clawback Run has been completed.","examples":["2025/08/03 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region ID associated with each Constraint Requirements","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The RunNo associated with the Clawback Run for the above interval date time.","examples":["2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The adjusted cost of the constraint for this service, after the regulation/contingency split. This is adjusted by the Base Cost Adjustment Ratio.","examples":["0.10138967","0","260.75012416"],"is_float":true},"BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Base cost of the constraint before the regulation/contingency split. SUM(REGION_BASE_COST) Group by interval datetime, ConstraintId","examples":["0.10138967","260.75012416"],"is_float":true},"CONSTRAINT_ENABLEMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"How much is enabled for this bid Type within the constraint. Sum(Regional_Enablement) Group by Interval_Datetime, ConstraintId, BidType","examples":["44.4248","35","625.8703","304"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/03/05 10:29:31"],"parse_csv_as_string":true,"is_s_datetime":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"P Regulation value is not affected by Clawback. This value is copied from Original Data source(DISPATCH )","examples":["0.07","0","14.9"],"is_float":true},"PREV_ADJUSTED_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Cost before override","examples":["0.10455634","0","260.75012417"],"is_float":true},"PREV_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Base Cost before Override","examples":["0.10455634","260.75012417"],"is_float":true},"PREV_CONSTRAINT_ENABLEMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Constraint Enablement before Override","examples":["44.4248","35","626.15801","304"],"is_float":true},"PREV_REGION_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region Base Cost before Override","examples":["0.075","0","1","103.05833333"],"is_float":true},"PREV_REGION_ENABLEMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional Enablement before Override","examples":["4.18502","0","8","299"],"is_float":true},"REGION_BASE_COST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region Base Cost adjusted by the Regional Enablement Adj Ratio","examples":["0.075","0","1","103.05833333"],"is_float":true},"REGION_ENABLEMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Overridden Regional Enablement. SUM(FCAS MW) from FCAS.Clawback_Unitsolution","examples":["4.18502","0","8","299"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_FCAS_CLAWBACK_REQ%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2026,"month":1},"last_month":{"year":2026,"month":7},"compressed_size_per_month":7569673,"decompressed_size_all_time":312577010},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_CLAWBACK_RUN_TRK":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_CLAWBACK_RUN_TRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#61"],"comment":"This Settlements FCAS Clawback Run Track report contains the Interval Datetime for which a Clawback has occurred and included in the Settlement run. The report will be produced only if there is any Clawback Run for the Interval date time in the Settlement Date","primary_keys":["INTERVAL_DATETIME","SETTLEMENTDATE","VERSIONNO"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Interval Datetime for which a Clawback Run has been completed.","examples":["2025/08/06 20:45:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2025/08/06 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","examples":["7","12"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLAWBACK_DATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":false,"comment":"The Date time the Clawback data has been loaded into the System for processing.","examples":["2026/02/03 00:00:00"],"parse_csv_as_string":true,"is_date":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last changed Date time of the record","examples":["2026/02/04 13:29:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PREV_DATA_SOURCE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"CLAWBACK\", \"DISPATCH\"])","mandatory":false,"comment":"The Clawback Data source Used. If this interval has any Clawback already applied in past then value will be CLAWBACK , else DISPATCH. For the first Clawback processing for the Interval the Source is DISPATCH.","examples":null,"enums":["CLAWBACK","DISPATCH"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"The RunNo associated with the Clawback for the above interval date time.","examples":["1","3"],"is_integer":true,"unsigned_int":true,"num_int_bits":16}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_FCAS_CLAWBACK_RUN_TRK%23FILE01%23202607010000.zip","manifest_summary":{"first_month":{"year":2026,"month":1},"last_month":{"year":2026,"month":7},"compressed_size_per_month":77035,"decompressed_size_all_time":2974790},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_CLAWBACK_UNITSOLN":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_CLAWBACK_UNITSOL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#67"],"comment":"This report contains the Interval Datetime affected by the Clawback Run and the reduced MW for the FCAS Service for each affected DUID.","primary_keys":["DUID","INTERVAL_DATETIME","RUNNO"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The DUID for which the Reduced MW has been applied for the FCAS Service.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Interval Datetime for which a the Clawback Run has been completed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The RunNo associated with the Clawback Run for the above interval date time.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the LOWER1SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"LOWER5MIN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the LOWER5MIN Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"LOWER6SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the LOWER6SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"LOWER60SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the LOWER60SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"LOWERREG":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the LOWERREG Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"RAISE1SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the RAISE1SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"RAISE5MIN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the RAISE5MIN Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"RAISE6SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the RAISE6SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"RAISE60SEC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the RAISE60SEC Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true},"RAISEREG":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Clawback Volume for the RAISEREG Service. If this service is not affected in that Clawback then retain Prev Value.","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_PAYMENT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_PAYMENT","VERSION":6}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#73"],"comment":"SET_FCAS_PAYMENT sets out the enabling payment details for frequency controlled Ancillary Services.","description":"SET_FCAS_PAYMENT data is confidential to the relevant participant.\n\nVolume\n\nApproximately 150,000 per week.","primary_keys":["DUID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount for the very fast lower service","is_float":true},"LOWER5MIN_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 Minute Payment","is_float":true},"LOWER6SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 Second Payment","is_float":true},"LOWER60SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 Second Payment","is_float":true},"LOWERREG_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 Minute Regulation Payment","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant identifier","is_categorical":true},"RAISE1SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Payment amount for the very fast raise service","is_float":true},"RAISE5MIN_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 Minute Payment","is_float":true},"RAISE6SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 Second Payment","is_float":true},"RAISE60SEC_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 Second Payment","is_float":true},"RAISEREG_PAYMENT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 Minute Regulation Payment","is_float":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"After posting of a billing run"},"SET_FCAS_RECOVERY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_RECOVERY","VERSION":8},{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_RECOVERY","VERSION":9}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56.htm#82","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec56_1.htm"],"comment":"SET_FCAS_RECOVERY shows reimbursements for the Frequency Control Ancillary Services (FCAS) to be recovered from participants. Beware of potential confusion with the table SETFCASRECOVERY, which reports reimbursements for Frequency Control Ancillary Services Compensation (now unused).","description":"SET_FCAS_RECOVERY data is confidential to the relevant participant.\n\nVolume\n\nApproximately 1, 500, 000 per week.","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Participant identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"VARCHAR2(3)","pl_type":"str","mandatory":true,"comment":"Settlement Run No","unsigned_int":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower1Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER1SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower1Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER1SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer recovery amount for the very fast lower service. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER1SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator recovery amount for the very fast lower service. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER5MIN_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower5Min FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER5MIN_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower5Min FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER5MIN_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 5 Minute service attributable to customer connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER5MIN_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 5 Minute service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER6SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower6Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER6SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower6Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER6SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 6 Second service attributable to customer connection points. NULL for Settlement date post the IESS rule effective date","is_float":true},"LOWER6SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 6 Second service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER60SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower60Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER60SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower60Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"LOWER60SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 60 Second service attributable to customer connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWER60SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Lower 60 Second service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"LOWERREG_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Regulation FCAS Residue Recovery Amount using ACE MWh values excluding the MPF Connection Points. NULL value for Settlement Dates prior to the IESS rule effective date. For Settlement dates past FPP Rule Effective date this column will be LOWERREG_USED_ACE + LOWERREG_UNUSED_ACE","is_float":true},"LOWERREG_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"This column is LOWERREG_USED_ASOE + LOWERREG_UNUSED_ASOE. For Settlement dates prior to FPP Rule Effective date this column will be NULL","is_float":true},"LOWERREG_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"For Settlement Date post the IESS rule effective date the column represent the Lower Regulation FCAS MPF Recovery Amount from Customer and Generator Connection Point MPFs only. Residue Recovery Amount is not included in this amount. For Settlement Dates past FPP Rule Effective Dates this column will be NULL.","is_float":true},"LOWERREG_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"For Settlement date prior to the IESS rule effective date, the column represent Sum of MPF Lower Regulation recovery amount from Generator Connection Points. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"LOWERREG_UNUSED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Unused amount for the Participant and Region","is_float":true},"LOWERREG_UNUSED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Unused ACE Portion amount for the Participant and Region","is_float":true},"LOWERREG_UNUSED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Unused ASOE Portion amount for the Participant and Region","is_float":true},"LOWERREG_UNUSED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Unused Residual amount for the Participant and Region LowerReg_Unused_ACE + LowerReg_Unused_ASOE","is_float":true},"LOWERREG_USED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Used amount for the Participant and Region","is_float":true},"LOWERREG_USED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Used ACE Portion amount for the Participant and Region","is_float":true},"LOWERREG_USED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Used ASOE Portion amount for the Participant and Region","is_float":true},"LOWERREG_USED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Used Residual amount for the Participant and Region(LowerReg_Used_ACE + LowerReg_Used_ASOE)","is_float":true},"RAISE1SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise1Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE1SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise1Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE1SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Customer recovery amount for the very fast raise service. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISE1SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Generator recovery amount for the very fast raise service. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISE5MIN_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise5Min FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE5MIN_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise5Min FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE5MIN_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 5 Minute service attributable to customer connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISE5MIN_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 5 Minute service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISE6SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise6Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE6SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise6Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE6SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 6 Second service attributable to customer connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISE60SEC_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise60Sec FCAS Recovery Amount for the Participant and Region from ACE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE60SEC_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise60Sec FCAS Recovery Amount for the Participant and Region from ASOE MWh Portion. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RAISE60SEC_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 60 Second service attributable to customer connection points. NULL for Settlement dates post the IESS rule effective date","is_float":true},"RAISEREG_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Regulation FCAS Residue Recovery Amount using ACE MWh values excluding the MPF Connection Points. NULL Value for Settlement Dates prior to the IESS rule effective date. For Settlement dates past FPP Rule Effective date this column will be RAISEREG_USED_ACE + RAISEREG_UNUSED_ACE","is_float":true},"RAISEREG_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"This column is RAISEREG_USED_ASOE + RAISEREG_UNUSED_ASOE. For Settlement dates prior to FPP Rule Effective date this column will be NULL","is_float":true},"RAISEREG_RECOVERY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"For Settlement Date post the IESS rule effective date the column represent the Raise Regulation FCAS MPF Recovery Amount from Customer and Generator Connection Point MPFs only. Residue Recovery Amount is not included in this amount. For Settlement Dates past FPP Rule Effective Dates this column will be NULL.","is_float":true},"RAISEREG_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"For Settlement date prior to the IESS rule effective date, the column represent Sum of MPF Raise Regulation recovery amount from Generator Connection Points. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"RAISEREG_UNUSED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Unused amount for the Participant and Region","is_float":true},"RAISEREG_UNUSED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Unused ACE Portion amount for the Participant and Region","is_float":true},"RAISEREG_UNUSED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Unused ASOE Portion amount for the Participant and Region","is_float":true},"RAISEREG_UNUSED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Unused Residual amount for the Participant and Region RaiseReg_Unused_ACE + RaiseReg_Unused_ASOE","is_float":true},"RAISEREG_USED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Used amount for the Participant and Region","is_float":true},"RAISEREG_USED_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Used ACE Portion amount for the Participant and Region","is_float":true},"RAISEREG_USED_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Used ASOE Portion amount for the Participant and Region","is_float":true},"RAISEREG_USED_RESIDUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Used Residual amount for the Participant and Region RaiseReg_Used_ACE + RaiseReg_Used_ASOE","is_float":true},"RAISE6SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 6 Second service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","unused":true,"is_float":true},"RAISE60SEC_RECOVERY_GEN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery amount for the Raise 60 Second service attributable to generator connection points. NULL for Settlement dates post the IESS rule effective date","unused":true,"is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"},{"msg":"This is a different table to SETFCASRECOVERY","category":"related_tables"}],"trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run","pagination":["Elec56_1.htm"]},"SET_FCAS_REGULATION_TRK":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"SET_FCAS_REGULATION_TRK","VERSION":2},{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"SET_FCAS_REGULATION_TRK","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#115"],"comment":"SET_FCAS_REGULATION_TRK shows FCAS Regulation Service Constraint tracking for Regional FCAS Regulation recovery","description":"SET_FCAS_REGULATION_TRK contains public data and is available to all\nparticipants.\n\nVolume\n\nApproximately 350,000 per week.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint ID","examples":["F_I+LREG_0210","F_I+NIL_APD_TL_L5","F_I+NIL_MG_R5","F_I+RREG_0220","F_MAIN++LREG_0210","F_MAIN+LREG_0210","F_MAIN+RREG_0220","F_T+LREG_0050","F_T+RREG_0050","F_TASCAP_LREG_0210","F_TASCAP_RREG_0220"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Dispatch Interval Date Time","examples":["2026/08/31 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run No","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Market Participant Factor. This column is NULL for Settlement Dates past FPP Rule Effective Date","is_float":true},"CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Residual Market Participant Factor. This column is NULL for Settlement Dates past FPP Rule Effective Date","is_float":true},"DRCF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The DRCF Value from the FPP Inputs for the Constraint Id used to calculate Unused Residual Amount","examples":["-0.08762999","-0.63949506"],"is_float":true},"FPP_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total FPP Amount from Eligible Units for the Constraint Id","examples":["-0.00424935","0.00017035","0","151.79593039"],"is_float":true},"FPP_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total FPP Residual Amount for the Constraint Id","examples":["-0.00017035","0.00424935","0","54.9036097"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"NRCF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NRCF Value from the FPP Inputs for the Constraint Id used to calculate Used Residual Amount","examples":["-0.00035401","0","-0.99966273"],"is_float":true},"P_REGULATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The PRegulation Value from Constraints FCAS Requirement data","examples":["0.01","5","22.25142","10"],"is_float":true},"RCF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RCF Value from the FPP Inputs for the Constraint Id used to calculate FPP Residual","examples":["-0.00035401","0.00236515","0","0.78731264"],"is_float":true},"RCR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RCR Value from the FPP Inputs for the Constraint Id used to calculate FPP Amount","examples":["8.51092","0","695.47606"],"is_float":true},"RECOVERY_FACTOR_CMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery factor for CMPF based recovery. This column is NULL for Settlement Dates past FPP Rule Effective Date","is_float":true},"RECOVERY_FACTOR_CRMPF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Recovery factor for CRMPF based recovery. This column is NULL for Settlement Dates past FPP Rule Effective Date.","is_float":true},"REQUIREMENTDEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"the aggregate customer demand value used to recover the cost of this requirement","examples":["-84.70725064","-1992.50057497"],"is_float":true},"RESIDUALTOTAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total residual MWh(ABS(ACE_MWh) + ASOE(MWh)) of the requirement regions.","examples":["87.45846842","2217.60554949"],"is_float":true},"TSFCAS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Adjusted Cost Value from Constraints FCAS Requirement data","examples":["0.175","8","261.375","52"],"is_float":true},"UNUSED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Reg Unused Amount from Eligible Units for the Constraint Id","examples":["-0.05985318","0","-94.49015056"],"is_float":true},"UNUSED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Reg Unused Residual Amount for the Constraint Id","examples":["-0.02333166","0","-57.57664904"],"is_float":true},"USAGE_VALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Usage Value from the FPP Inputs for the Constraint Id used to calculate Used Amount","examples":["0.00337","0","1","0.98709276"],"is_float":true},"USED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Reg Used Amount from Eligible Units for the Constraint Id","examples":["-0.00079495","0","-138.47368102"],"is_float":true},"USED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Reg Used Residual Amount for the Constraint Id","examples":["-0.00001254","0","-63.39381704"],"is_float":true},"USESUBSTITUTEDEMAND":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Flag to indication that substitute demand was used to recover this requirement","is_boolean":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_FCAS_REGULATION_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":13343339,"decompressed_size_all_time":3523326240},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_REG_AMOUNT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_REG_AMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#91"],"comment":"This report contains the the FCAS Regulation Amounts that include FPP Amounts, Used Amounts and Unused Amounts calculated using the Contribution Factors","primary_keys":["CONSTRAINTID","PERIODID","SETTLEMENTDATE","UNITID","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Regulation Constraint ID","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The UNITID with CF factor assigned. This is a DUID or a TNI. Refer table FPP_CONTRIBUTION_FACTOR","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType LOWERREG or RAISEREG for the Constraint ID","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP Amount calculated for the Constraint and UNITID using the FPP Contribution Factor","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Participant Id Identifier","is_categorical":true},"UNUSED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regulation Unused Recovery Amount from Eligible Units using DCF Value","is_float":true},"USED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regulation Used Recovery Amount from the eligible Units using Negative CF Value","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_REG_DEF_AMT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_REG_DEF_AMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#97"],"comment":"This report contains the the FCAS Regulation Amounts that include FPP Amounts, Used Amounts and Unused Amounts calculated using the Default Contribution Factors. This is when FPP Factors are not available for a particular interval and system used DCF in the calculation.","primary_keys":["CONSTRAINTID","PERIODID","SETTLEMENTDATE","UNITID","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Regulation Constraint ID","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"UNITID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The UnitId with CF factor assigned. This is a DUID or a TNI. Refer table FPP_CONTRIBUTION_FACTOR","is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType LOWERREG or RAISEREG for the Constraint ID","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The Participant Id Identifier","is_categorical":true},"UNUSED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regulation Unused Recovery Amount from Eligible Units using DCF Value","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_REG_DEF_RESIDAMT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_REG_DEF_RESIDAMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#103"],"comment":"This report contains the FCAS Regulation Residue Amounts that include FPP Residual Amounts, Used Residual Amounts and Unused Residual Amounts calculated using the Energy Ratio for each Requirement Region and the Default Residual CF.","primary_keys":["CONSTRAINTID","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Regulation Constraint ID","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The RegionId used for the residual calculation. This is the Constraint Requirement Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value that is used for the Residual Calculation.(Excluding CPID with CF)","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ASOE MWh value that is used for the Residual Calculation.(Excluding CPID with CF)","is_float":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType LOWERREG or RAISEREG for the Constraint ID","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ABS(ACE_MWh) + ASOE_MWh. The MWh is not netted for residual calculation.","is_float":true},"UNUSED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ACE Amount calculated using the ACE MWh value of the requirement regions.","is_float":true},"UNUSED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ASOE Amount calculated using the ASOE MWh value of the requirement regions.","is_float":true},"UNUSED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of UNUSED_ACE_AMOUNT + UNUSED_ASOE_AMOUNT.","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FCAS_REG_RESIDAMT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FCAS_REG_RESIDAMT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#109"],"comment":"This report contains the FCAS Regulation Residue Amounts that include FPP Residual Amounts, Used Residual Amounts and Unused Residual Amounts calculated using the Energy Ratio for each Requirement Region.","primary_keys":["CONSTRAINTID","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The FCAS Regulation Constraint ID","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The RegionId used for the residual calculation. This is the Constraint Requirement Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value that is used for the Residual Calculation.(Excluding CPID with CF)","is_float":true},"ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ASOE MWh value that is used for the FCAS Residual Calculation.(Excluding CPID with CF).","is_float":true},"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":false,"comment":"The BidType LOWERREG or RAISEREG for the Constraint ID","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"FPP_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ACE Amount calculated using the portion of ACE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"FPP_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The FPP ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"FPP_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of FPP_ACE_Amount + FPP_ASOE_Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESIDUAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of ABS(ACE_MWh) + ASOE_MWh. The MWh is not netted for residual calculation.","is_float":true},"UNUSED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ACE Amount calculated using the portion of ACE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"UNUSED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Unused Recovery ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"UNUSED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of UNUSED_ACE_AMOUNT + UNUSED_ASOE_AMOUNT.","is_float":true},"USED_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used Recovery ACE Amount calculated using the ACE MWh value of the requirement regions.","is_float":true},"USED_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Used Recovery ASOE Amount calculated using the portion of ASOE MWh value against the Total residual MWh of the requirement regions.","is_float":true},"USED_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of USED_ACE_AMOUNT + USED_ASOE_AMOUNT.","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_FPP":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"FPP","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#124"],"comment":"This report contains the summary of FPP Amounts for each ParticipantId in each region","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant Id Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Period ID Identifier","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The RegionId used for the residual calculation. This is the Constraint Requirement Region.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Changed Date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWERREG_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Amount from the ACE Portion of the Residual amount","is_float":true},"LOWERREG_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Amount from the Eligible Units.","is_float":true},"LOWERREG_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The LowerReg Amount from the ASOE Portion of the Residual amount","is_float":true},"LOWERREG_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Lower Reg Residual Amount which is also LowerReg_ACE_Amount + LowerReg_ASOE_Amount","is_float":true},"RAISEREG_ACE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Amount from the ACE Portion of the Residual amount","is_float":true},"RAISEREG_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Amount from the Eligible Units.","is_float":true},"RAISEREG_ASOE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RaiseReg Amount from the ASOE Portion of the Residual amount","is_float":true},"RAISEREG_RESIDUAL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Raise Reg Residual Amount which is also RaiseReg_ACE_Amount + RaiseReg_ASOE_Amount","is_float":true}},"visibility":"Private","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_IRSR_DIRECTIONAL_LINK":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRSR_DIRECTIONAL_LINK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#130"],"comment":"This report contains the MW Flow and Inter-Regional Residue Amounts for all primary interconnectors.","primary_keys":["FROMREGIONID","INTERCONNECTORID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"columns":{"FROMREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"The Exporting Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Interconnector Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Settlement Period Id(1-288)","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTERCONNECTORLOOPID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The Interconnector Loop Identifier, Blank if Interconnector not part of the loop"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MWFLOW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Consumed Energy in MWh","is_float":true},"ORG_SURPLUSVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Original Surplus Value","is_float":true},"SURPLUSVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Updated Surplus Value for the primary interconnector","is_float":true}},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_IRSR_LOOP_NETTRADE_AMOUNT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRSR_LOOP_NETTRADE_AMOUNT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#136"],"comment":"This report contains the final net trade amount for the two directional interconnectors to allocate.","primary_keys":["FROMREGIONID","INTERCONNECTORID","INTERCONNECTORLOOPID","PERIODID","SETTLEMENTDATE","VERSIONNO"],"columns":{"FROMREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"The Exporting Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Interconnector Identifier","is_categorical":true},"INTERCONNECTORLOOPID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Interconnector Loop Identifier"},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Settlement Period Id(1-288)","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"FINALNETTRADEAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Final Net Trade Amount","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NETREGIONAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Net Flow for the Region","is_float":true},"NLA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Net Loop Allocation(can be positive or negative)","is_float":true},"NOTIONALAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Notional Amount for each direction interconnector","is_float":true},"PROVNETTRADEAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Provisional Net Trade Amount based on the Positive Allocation","is_float":true},"REGIONRRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Exporting Region RRP","is_float":true},"RRPDIFF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Importing and Exporting Region RRP difference","is_float":true}},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_IRSR_LOOP_NSP_ALLOCATION":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRSR_LOOP_NSP_ALLOCATION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#142"],"comment":"This report contains Inter-Regional Negative Residue Amounts to allocate to TNSPs.","primary_keys":["INTERCONNECTORLOOPID","PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"INTERCONNECTORLOOPID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Interconnector Loop Identifier"},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The TNSP Participant Identifier","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Settlement Period Id(1-288)","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ALLOCATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Portion %(e.g. 100)","is_float":true},"AVGREGION_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Annual Regional Demand for the Region","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NLA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Net Loop Allocation(negative only)","is_float":true},"RESIDUE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Negative Residue Amount based on regional share","is_float":true},"TOTALREGION_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Annual Regional Demand for all Regions in the Loop","is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_IRSR_LOOP_REGION_SUMMARY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"IRSR_LOOP_REGION_SUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#148"],"comment":"This report contains Inter-Regional Net Loop Allocations and Net Regional Export Quantities.","primary_keys":["INTERCONNECTORLOOPID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"columns":{"INTERCONNECTORLOOPID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"The Interconnector Loop Identifier"},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Settlement Period Id(1-288)","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The Region Id","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No","is_integer":true,"unsigned_int":true,"num_int_bits":16},"EXPORT_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Export Flow in MWh for the Region","is_float":true},"IMPORT_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Import Flow in MWh for the Region","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NEGLOOPALLOCATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Negative Allocation across the Loop","is_float":true},"NETREGIONAL_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Net Flow for the Region","is_float":true},"NLA":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Net Loop Allocation(can be positive or negative)","is_float":true},"POSLOOPALLOCATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total Positive Allocation across the Loop","is_float":true}},"visibility":"Public","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_MR_PAYMENT":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#968"],"comment":"SET_MR_PAYMENT shows trading interval payments on a dispatchable unit basis for accepted MR capacity.","description":"SET_MR_PAYMENT data is confidential to the relevant participant.\n\nSource\n\nSET_MR_PAYMENT updates are ad hoc, being for MR events only.\n\nVolume\n\n24000 rows per year","unused":true,"primary_keys":["DUID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for DUID / MNSP LinkID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Calendar day Trading Interval number","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date (Calendar)","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run Number for this date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CAPPED_PAYMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Capped Trading Interval Payment","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MR_CAPACITY":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Accepted MR Capacity","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Participant identifier","is_categorical":true},"UNCAPPED_PAYMENT":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Uncapped Trading Interval Payment","is_float":true}},"visibility":"Private","trigger":"Ad hoc, when there are MR events"},"SET_MR_RECOVERY":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#977"],"comment":"SET_MR_RECOVERY shows the trading interval recovery charges on a dispatchable unit basis for spot market income from dispatch of MR capacity.","description":"SET_MR_RECOVERY data is confidential to the relevant participant.\n\nSource\n\nSET_MR_RECOVERY updates are ad hoc, being for MR events only.\n\nVolume\n\n24000 rows per year","unused":true,"primary_keys":["DUID","PERIODID","REGIONID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for DUID / MNSP LinkID","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Calendar day Trading Interval number","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date (Calendar)","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run Number for this date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ARODEF":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Accepted Restriction Offer Dispatched Energy Factor","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date/Time record inserted/modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NTA":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount payable to AEMO for that accepted restriction offer and trading interval","is_float":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Participant identifier","is_categorical":true}},"visibility":"Private","trigger":"Ad hoc, when there are MR events"},"SET_NMAS_MANUAL_PAYMENT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"NMAS_MANUAL_PAYMENT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#154"],"comment":"This report contains the NMAS Manual TI Payments that are uploaded by the Settlement Business Team. Amounts in this table are not calculated by the Settlement System.","primary_keys":["CONTRACTID","DUID","PARTICIPANTID","PAYMENTTYPE","PERIODID","SERVICETYPE","SETTLEMENTDATE","VERSIONNO"],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Contract ID.","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The DUID associated with the Contract Payment.","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Contract Participant Id.","is_categorical":true},"PAYMENTTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Payment Type associated with the Service like Availability, Usage, Enablement, Energy Revenue, Test, ADHOC and so on.","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"The Settlement Period Id (1-288).","is_integer":true,"num_int_bits":16},"SERVICETYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS System Security Service Types (INERTIA, SYSTEM STRENGTH, TYPE1, TYPE2 and so on).","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The Settlement Date of the Billing Week.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The Settlement Run No.","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date time of the record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENTAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The NMAS Contract Manual Payment for the Payment Type.","is_float":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"The Contract Region Id.","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_NMAS_RECOVERY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"NMAS_RECOVERY","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#160"],"comment":"SET_NMAS_RECOVERY sets out the NSCAS recovery data for payments other than testing This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","primary_keys":["CONTRACTID","PARTICIPANTID","PAYMENTTYPE","PERIODID","REGIONID","SERVICE","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS/ISF Contract Id","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The Participant from whom the amount is recovered","is_categorical":true},"PAYMENTTYPE":{"sql_type":"VARCHAR(20)","pl_type":"pl.Enum([\"AVAILABILITY\", \"ENABLEMENT\", \"COMPENSATION\"])","mandatory":true,"comment":"The type of payment being recovered. Valid values are:\n- AVAILABILITY\n- ENABLEMENT\n- COMPENSATION","examples":null,"enums":["AVAILABILITY","ENABLEMENT","COMPENSATION"]},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region from where the amount is recovered","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"REACTIVE\", \"LOADSHED\", \"RESTART\", \"INERTIA\", \"SYSTEM STRENGTH\", \"TYPE1\", \"TYPE2\"])","mandatory":true,"comment":"The type of NSCAS service incl ISF Services. Current value values are:\n- REACTIVE\n- LOADSHED\n- RESTART\n- INERTIA, SYSTEM STRENGTH, TYPE1, TYPE2","examples":null,"enums":["REACTIVE","LOADSHED","RESTART","INERTIA","SYSTEM STRENGTH","TYPE1","TYPE2"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Updated date and time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANT_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ACE MWh value for the Participant used in the Recovery Amount Calculation. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"PARTICIPANT_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The ASOE MWh value for the Participant used in the Recovery Amount Calculation. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"PARTICIPANT_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Participant energy in MWh for the period. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true},"PARTICIPANT_GENERATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Participant Generator Energy in the benefitting region. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Payment Amount to recover from all benefitting regions","is_float":true},"RBF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Benefitting Factor for the RegionId","is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total recovery amount for the period for the PARTICIPANTID and REGIONID. For Settlement dates prior to the IESS rule effective date Sum of RECOVERY_AMOUNT_CUSTOMER + RECOVERY_AMOUNT_GENERATOR and Post IESS it is sum of RECOVERYAMOUNT_ACE + RECOVERYAMOUNT_ASOE.","is_float":true},"RECOVERY_AMOUNT_CUSTOMER":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The recovery amount allocated to customers. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true},"RECOVERY_AMOUNT_GENERATOR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The recovery amount allocated to generators. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true},"RECOVERYAMOUNT_ACE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Recovery dollar amount for the Participant for the NMAS Contract Id calculated using the ACE MWh values for eligible services. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"RECOVERYAMOUNT_ASOE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Recovery dollar amount for the Participant for the NMAS Contract Id calculated using the ASOE_MWh values for eligible services. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"REGION_ACE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional ACE MWh value used in the Recovery Amount Calculation. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"REGION_ASOE_MWH":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Regional ASOE MWh value used in the Recovery Amount Calculation. NULL Value for Settlement Dates prior to the IESS rule effective date.","is_float":true},"REGION_ENERGY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The RegionId energy in MWh for the period. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true},"REGION_GENERATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The generator energy in the benefitting region. NULL Value for Settlement Dates post IESS rule effective date.","is_float":true}},"visibility":"Private","trigger":"Settlement Run"},"SET_NMAS_RECOVERY_RBF":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"NMAS_RECOVERY_RBF","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#168"],"comment":"SET_NMAS_RECOVERY_RBF publishes the RBF for NSCAS non testing payments on a half hourly basis. This Table may also be used for NSCAS and Type 1 transitional services procured by AEMO under the ISF framework during 2025 and prior to the implementation of all system changes. During this time descriptions in these tables may not be correct.","primary_keys":["CONTRACTID","PAYMENTTYPE","PERIODID","REGIONID","SERVICE","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"The NMAS/ISF Contract Id","examples":["#85JD#9&4K","%00BNU%TA@","8CU$RB4TPY","9W5K7VED1J","@E7848PJX3","@KX44U1LW2","@T#KLMM#AG","GS0BD5R&S0","HZCHJFJ67Z","NXQ53L#5GB","Z0ULFN2DYE"],"is_categorical":true},"PAYMENTTYPE":{"sql_type":"VARCHAR(20)","pl_type":"pl.Enum([\"AVAILABILITY\", \"ENABLEMENT\", \"COMPENSATION\", \"ENABLING\"])","mandatory":true,"comment":"The type of payment being recovered. Valid values are:\n- AVAILABILITY\n- ENABLEMENT\n- COMPENSATION","examples":null,"enums":["AVAILABILITY","ENABLEMENT","COMPENSATION","ENABLING"]},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Settlements Trading Interval.","examples":["1","19"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"The region from where the amount is recovered","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SERVICE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"REACTIVE\", \"LOADSHED\", \"RESTART\", \"INERTIA\", \"SYSTEM STRENGTH\", \"TYPE1\", \"TYPE2\"])","mandatory":true,"comment":"The type of NSCAS service incl ISF Services. Current value values are:\n- REACTIVE\n- LOADSHED\n- RESTART\n- INERTIA, SYSTEM STRENGTH, TYPE1, TYPE2","examples":null,"enums":["REACTIVE","LOADSHED","RESTART","INERTIA","SYSTEM STRENGTH","TYPE1","TYPE2"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Settlement Date","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The Last Updated date and time","examples":["2026/09/01 01:12:12"],"parse_csv_as_string":true,"is_s_datetime":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total Payment Amount to recover from all benefitting regions","examples":["10.38","97.31"],"is_float":true},"RBF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Benefitting Factor for the RegionId","examples":["0","1"],"is_float":true},"RECOVERY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Total recovery amount for the period for the REGIONID","examples":["-10.37999905","0","-97.30999893"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SET_NMAS_RECOVERY_RBF%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":21001227,"decompressed_size_all_time":4052836160},"visibility":"Public","trigger":"Settlement Run"},"SET_RECOVERY_ENERGY":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"RECOVERY_ENERGY","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#176"],"comment":"Settlements substitution recovery energy used","primary_keys":["PARTICIPANTID","PERIODID","REGIONID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the participant","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier, with Period 1 being the first TI for the calendar day, i.e interval ending 00:05 for 5MS or 00:30 for 30MS.","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique Identifier for the Region to which the TNI belongs on this settlement date","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ACE_MWH_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Actual ACE MWh Value for the Recovery Calculation. NULL Value for Settlement date prior to the IESS rule effective date","is_float":true},"ACE_MWH_MPFEX_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Actual ACE MWh Value excluding the MPF Connection Points for the Recovery Calculation. This is used only in FCAS Residue Recovery Calculation. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"ACE_MWH_MPFEX_SUBSTITUTE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Substitute ACE MWh Value excluding the MPF Connection Points for the Recovery Calculation. This is used only in FCAS Residue Recovery Calculation. There is no substitute demand post IESS Rule Change. Hence this column will have same value as ACE_MWh_MPFExActual. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"ACE_MWH_SUBSTITUTE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Substitute ACE MWh Value for the Recovery Calculation. There is no substitute demand post IESS Rule Change. Hence this column will have same value as ACE_MWh_Actual. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"ASOE_MWH_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Actual ASOE MWh Value for the Recovery Calculation. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"CUSTOMERENERGYACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Actual Customer Demand. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"CUSTOMERENERGYMPFEXACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Actual Customer Demand excluding TNIs that have a causer pays MPF. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"CUSTOMERENERGYMPFEXSUBSTITUTE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute Customer Demand excluding TNIs that have a causer pays MPF. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"CUSTOMERENERGYSUBSTITUTE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute Customer Demand. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"GENERATORENERGYACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Actual Generator Output. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"REGION_ACE_MWH_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region total of Actual ACE MWh Value. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"REGION_ACE_MWH_MPFEX_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region total of Actual ACE MWh Value excluding the MPF Connection Points. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"REGION_ACE_MWH_MPFEX_SUBST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region total of Substitute ACE MWh Value excluding the MPF Connection Points . NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"REGION_ACE_MWH_SUBST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region total of Substitute ACE MWh Value. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"REGION_ASOE_MWH_ACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Region total of Actual ASOE MWh Value. NULL Value for Settlement date prior to the IESS rule effective date.","is_float":true},"REGIONCUSTENERGYACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Total of Actual Customer Demand. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"REGIONCUSTENERGYSUBST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Total of Substitute Customer Demand. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"REGIONGENENERGYACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Total of Actual Generator Output. NULL for Settlement dates post the IESS rule effective date.","is_float":true},"REGIONCUSTENERGYMPFEXACTUAL":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Total of Actual Customer Demand excluding TNIs that have a causer pays MPF. NULL for Settlement dates post the IESS rule effective date.","unused":true,"is_float":true},"REGIONCUSTENERGYMPFEXSUBST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Region total of Substitute Customer Demand excluding TNIs that have a causer pays MPF. NULL for Settlement dates post the IESS rule effective date.","unused":true,"is_float":true}},"visibility":"Private","trigger":"Daily Billing Run & Posting a PRELIM/FINAL and REVISE Billing Run"},"SET_RUN_PARAMETER":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#986"],"comment":"SET_RUN_PARAMETER shows the input parameters and value associated with each settlement run (e.g. Residual System Load Causer Pays Factor).","description":"Change History\n\n19 August 2005 for 4.5.0:\n\nChanged index name again to have suffix of \\_LCX\n\nNote: primary key shows PK\\_ as prefix in Oracle SQL script, even though\nname of key has \\_PK as suffix - but cannot change since would not\nimprove participant systems .\n\n \n\n17 August 2005 for v4.5.0\n\nAdded tablespace (02) for recently added index, and gave index a better\nname","unused":true,"primary_keys":["PARAMETERID","SETTLEMENTDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"PARAMETERID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Parameter Identifier","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement Date (Calendar)","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement Run Number for this date","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date the record changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NUMVALUE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Settlement Run Amount for the Constant Identifier","is_float":true}},"visibility":"Public","trigger":"Posting a billing run"},"SET_SUBSTITUTE_DEMAND":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"SUBST_DEMAND","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#188"],"comment":"Settlements substitution demand for Zero Demand figures","primary_keys":["PARTICIPANTID","SETTLEMENTDATE","SETTLEMENTRUNNO","TNI"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the participant","is_categorical":true},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the connection point","is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Unique identifier for the region to which the TNI belongs to on this settlement date","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SUBSTITUTEDEMAND":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Substitute metered quantity for non-energy recovery in MWh for the TNI and participant in the trading interval. A negative value indicates net consumption and a positive value indicates net generation","is_float":true}},"visibility":"Private","trigger":"Posting a billing run"},"SET_SUBST_RUN_VERSION":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"SUBST_RUN_VERSION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#182"],"comment":"Settlements substitution demand run version numbers","primary_keys":["REFERENCESETTLEMENTDATE","REFERENCESETTLEMENTRUNNO","SETTLEMENTDATE","SETTLEMENTRUNNO"],"columns":{"REFERENCESETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The settlement date of a settlement run included in the reference period","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"REFERENCESETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"The settlement run number matching the settlement date for a settlement run included in the reference period","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Public","trigger":"Posting a billing run"},"SET_WDR_RECON_DETAIL":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"WDR_RECON_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#194"],"comment":"Settlements WDR reconciliation details","primary_keys":["NMI","PERIODID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"columns":{"NMI":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the meter to which the metering records applies","is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier with Period 1 being the first TI for the calendar day, that is the interval ending 00:05","is_integer":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"BASELINECALCULATIONID":{"sql_type":"VARCHAR2(100)","pl_type":"pl.Categorical","mandatory":false,"comment":"A reference to the baseline run that produced the baseline quantity for this NMI and interval","is_categorical":true},"BQ_DLFADJUSTED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Baseline quantity in MWh for the NMI in the trading interval. A negative quantity indicates net consumption, while a positive value indicates net generation","is_float":true},"DRSP":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique identifier for the participant acting as the DRSP for this NMI on the settlement date","is_categorical":true},"FRMP":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique identifier for the participant acting as the FRMP for this NMI on the settlement date"},"ISNONCOMPLIANT":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"A value of TRUE (indicated by 1) for this column indicates that financial settlement of WDR transactions for this NMI should not proceed for the settlement date and trading interval. Possible values are 1 and 0.","is_boolean":true},"ME_DLFADJUSTED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Metered quantity in MWh for the NMI trading interval. A negative value indicates net consumption and a positive value indicates net generation","is_float":true},"MRC":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum responsive component for the NMI (MW)","is_float":true},"MRCSQ":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum responsive component settlement quantity for the NMI (MWh)","is_float":true},"QUALITYFLAG":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Boolean","mandatory":false,"comment":"Quality flag for the meter read. Where multiple datastreams exist against the NMI with different quality flags for each read, the lowest quality flag will be published against the NMI for the interval","is_boolean":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Unique identifier for the region to which the TNI belongs on the settlement date","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RRP":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for the region in the settlement interval ($/MWh)","is_float":true},"TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Transmission loss factor for the wholesale connection point associated with the NMI","is_float":true},"TNI":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique identifier for the transmission node to which this meter belongs on the settlement date","is_categorical":true},"TRANSACTIONAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR transaction amount for this NMI in the settlement interval ($)","is_float":true},"WDRRR":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR reimbursement rate for the region ($/MWh)","is_float":true},"WDRSQ_CAPPED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR settlement quantity after capping or flooring (MWh)","is_float":true},"WDRSQ_UNCAPPED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"WDR settlement quantity before any capping or flooring (MWh)","is_float":true}},"visibility":"Private","trigger":"Posting a billing run"},"SET_WDR_TRANSACT":{"package":"SETTLEMENT_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"SETTLEMENTS","REPORT_SUB_TYPE":"WDR_TRANSACT","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec57.htm#200"],"comment":"Settlements WDR transactions summary","primary_keys":["COUNTERPARTYPARTICIPANTID","PARTICIPANTID","PARTICIPANTROLEID","PERIODID","REGIONID","SETTLEMENTDATE","SETTLEMENTRUNNO"],"columns":{"COUNTERPARTYPARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the counter participant id.","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for a participant","is_categorical":true},"PARTICIPANTROLEID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"FRMP\", \"DRSP\"])","mandatory":true,"comment":"Participant role identifier - FRMP or DRSP","examples":null,"enums":["FRMP","DRSP"]},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier with Period 1 being the first TI for the calendar day, that is the interval ending 00:05","is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Unique identifier for the region to which the TNI belongs on the settlement date","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Settlement date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"SETTLEMENTRUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Settlement run number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"TRANSACTIONAMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate WDR transaction amount for the participant and counterparty in the settlement interval","is_float":true}},"visibility":"Private","trigger":"Posting a billing run"},"SPDCONNECTIONPOINTCONSTRAINT":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"SPDCPC","REPORT_SUB_TYPE":"NULL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#78"],"comment":"SPDCONNECTIONPOINTCONSTRAINT sets out details of connections point constraints issued in dispatch, predispatch and STPASA.","description":"The addition of the BIDTYPE field to SPDCONNECTIONPOINTCONSTRAINT allows\nconstraints to be applied to a dispatchable unit energy and/or Frequency\nControlled Ancillary Services dispatch.\n\nSPDCONNECTIONPOINTCONSTRAINTdata is public, so is available to all\nparticipants.\n\nSource\n\nSPDCONNECTIONPOINTCONSTRAINT updates whenever new connection point\nconstraints are created.","primary_keys":["BIDTYPE","CONNECTIONPOINTID","EFFECTIVEDATE","GENCONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"Bid Type Identifier; one of (RAISE6SEC, RAISE60SEC, RAISE5MIN, LOWER6SEC, LOWER60SEC, LOWER5MIN, RAISEREG, LOWERREG)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(12)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point Identifier","examples":["NAL11C","NBK11B","NBKB3B","NBKW1S","NBL21L","NBSF1L","NBSF2S","NCLS1C","NDNH1H","NDNS1D","NFNS1F","NLMB1L","NMUR8","QBCB3B","QBCG","QBCK1","QBCK2","QBDR1L","QBGH1","QBGH2","QBKB1S","QBLG1G","QBRA1","QBRA2","QBRA3","QBRA4K","QBRA5B","QBRA6B","QBRA7B","QBRA8D","QBRS1D","QBSS1B","QBSS2B","QBSW1C","QBSW2C","QCAB1","QCAB2","QCAC3","QCAC4","QCBF1D","QCBR1C","QCBS1B","QCCK1D","QCCK2H","QCLA1C","QCND1C","QCOS1C","QCPG1C","QDMR1W","QDMW1W","QGAR1","QGBB1G","QGLD1","QGLD2","QGLD3","QGLD4","QGLD5","QGLD6","QHAR1H","QKAH1","QKAH2","QKAH3","QKAH4","QLCS1A","QLIS1E","QLIS2M","QLLV3C","QMPL1R","QMRR1M","QMRY1Y","QMRY2M","QMRY3W","QMRY4W","QMSP1","QMSP2","QMSP3M","QMSW1M","QOKY1","QOKY2","QORS1E","QRMA7","QRMA8","QROG1K","QROG3R","QROW1K","QROW2K","QSLD1H","QSLS1W","QSTB1S","QSTN1","QSTN2","QSTN3","QSTN4","QSWE","QTBS1C","QTBS2S","QTKS1O","QTKS2O","QTMW1K","QTNT","QTRB1T","QTRN1","QTRN2","QTRN3","QTRN4","QTRS1K","QTYP","QTZS1S","QWDB3C","QWDE3W","QWDE4W","QWDR1W","QWDS1U","QWIV1","QWIV2","QWKM1M","QWLB1W","QWLM1M","QWLS1W","QWSB3W","QWSR1W","QWSR2W","QWSS1G","SDCA1","SDCA2","SPPT","VART1A","VBA23B","VBAW1Y","VBBT1B","VBBT2B","VBGT1B","VBGT4B","VCB33R","VCPT1C","VCWL1C","VDPS","VELT1M","VELT2M","VELT3E","VGET1G","VGN21G","VGN61M","VGNS1G","VGNS2W","VGTW1M","VHOG1K","VHW23H","VKGB3G","VKGP1K","VKGS1G","VKGS2C","VKMT1K","VKOT1K","VMKP1","VMLB3V","VMRT1M","VMRT2M","VMWT12","VMWT9B","VPLT1P","VRCS1K","VRCS2Y","VSHS1N","VSHS2G","VSHS2W","VSHS3L","VSM71C","VTB21M","VTG21M","VTG31T","VTG61S","VTGT3A","VTR11H","VTR31R","VTRT1M","VWES1B","VWES2W","VWKP1","VYP21","VYP22","VYP23","VYP24"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint Identifier","examples":["#DRYCGT1_D_E","#DRYCGT2_D_E","#R036713_001_RAMP_F","#R036713_001_RAMP_V","#R036714_001_RAMP_F","#R036714_001_RAMP_V","#R036715_001_RAMP_F","#R036715_001_RAMP_V","#R036715_002_RAMP_F","#R036715_002_RAMP_V","#R036715_003_RAMP_F","#R036715_003_RAMP_V","#R036716_001_RAMP_F","#R036716_001_RAMP_V","#R036717_001_RAMP_F","#R036717_001_RAMP_V","#R036717_002_RAMP_F","#R036717_002_RAMP_V","#R036717_003_RAMP_F","#R036717_003_RAMP_V","#SSE_PPCCGT_20","CA_SYDS_59A889E5_1","V>>BELMLCB_BAML_TGML"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint factor","examples":["-0.181","0.158","1","0.996"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 02:06:54"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SPDCONNECTIONPOINTCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":702437,"decompressed_size_all_time":799637950},"visibility":"Public","trigger":"When a new connection point constraint is created"},"SPDINTERCONNECTORCONSTRAINT":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"SPDICC","REPORT_SUB_TYPE":"NULL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#87"],"comment":"SPDINTERCONNECTORCONSTRAINT contains details on the interconnector constraint factors used in dispatch, predispatch and STPASA. The details set a LHS value.","description":"SPDINTERCONNECTORCONSTRAINT is public data, and is available to all\nparticipants.\n\nSource\n\nSPDINTERCONNECTORCONSTRAINT updates whenever new connection point\nconstraints are created.","primary_keys":["EFFECTIVEDATE","GENCONID","INTERCONNECTORID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["2026/09/01 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint Identifier","examples":["#R036715_001_RAMP_F","#R036715_001_RAMP_V","#R036715_002_RAMP_F","#R036715_002_RAMP_V","#R036715_003_RAMP_F","#R036715_003_RAMP_V","#R036717_001_RAMP_F","#R036717_001_RAMP_V","#R036717_002_RAMP_F","#R036717_002_RAMP_V","#R036717_003_RAMP_F","#R036717_003_RAMP_V","#R036717_004_RAMP_F","#R036717_004_RAMP_V","#R036717_005_RAMP_F","#R036717_005_RAMP_V","#R036718_001_RAMP_F","#R036718_001_RAMP_V","#R036718_002_RAMP_F","#R036718_002_RAMP_V","#R036718_003_RAMP_F","#R036718_003_RAMP_V","#R036718_004_RAMP_F","#R036718_004_RAMP_V","#R036718_005_RAMP_F","#R036718_005_RAMP_V","#R036718_006_RAMP_F","#R036718_006_RAMP_V","#R036718_007_RAMP_F","#R036718_007_RAMP_V","#R036719_001_RAMP_F","#R036719_001_RAMP_V","#R036720_001_RAMP_F","#R036720_001_RAMP_V","#R036720_002_RAMP_F","#R036720_002_RAMP_V","#R036720_003_RAMP_F","#R036720_003_RAMP_V","#R036720_004_RAMP_F","#R036720_004_RAMP_V","#R036721_001_RAMP_F","#R036721_001_RAMP_V","#R036721_002_RAMP_F","#R036721_002_RAMP_V","#R036721_003_RAMP_F","#R036721_003_RAMP_V","#R036721_004_RAMP_F","#R036721_004_RAMP_V","#R036721_005_RAMP_F","#R036721_005_RAMP_V","#R036721_006_RAMP_F","#R036721_006_RAMP_V","#R036721_007_RAMP_F","#R036721_007_RAMP_V","#R036721_008_RAMP_F","#R036721_008_RAMP_V","#R036721_009_RAMP_F","#R036721_009_RAMP_V","#R036721_010_RAMP_F","#R036721_010_RAMP_V","#R036721_011_RAMP_F","#R036721_011_RAMP_V","#R036721_012_RAMP_F","#R036721_012_RAMP_V","#R036721_013_RAMP_F","#R036721_013_RAMP_V","#R036721_014_RAMP_F","#R036721_014_RAMP_V","#R036721_015_RAMP_F","#R036721_015_RAMP_V","#R036721_016_RAMP_F","#R036721_016_RAMP_V","#R036721_017_RAMP_F","#R036721_017_RAMP_V","#R036721_018_RAMP_F","#R036721_018_RAMP_V","#R036721_019_RAMP_F","#R036721_019_RAMP_V","#R036721_020_RAMP_F","#R036721_020_RAMP_V","#R036721_021_RAMP_F","#R036721_021_RAMP_V","#R036722_001_RAMP_F","#R036722_001_RAMP_V","#R036722_002_RAMP_F","#R036722_002_RAMP_V","#R036723_001_RAMP_F","#R036723_001_RAMP_V","#R036723_002_RAMP_F","#R036723_002_RAMP_V","#R036724_001_RAMP_F","#R036724_001_RAMP_V","#R036725_004_RAMP_F","#R036725_004_RAMP_V","#R036725_005_RAMP_F","#R036725_005_RAMP_V","#R036725_006_RAMP_F","#R036725_006_RAMP_V","#R036727_001_RAMP_F","#R036727_001_RAMP_V","#R036728_001_RAMP_F","#R036728_001_RAMP_V","#R036728_002_RAMP_F","#R036728_002_RAMP_V","#R036729_001_RAMP_F","#R036729_001_RAMP_V","#R036729_002_RAMP_F","#R036729_002_RAMP_V","#R036731_003_RAMP_F","#R036731_003_RAMP_V","#R036731_004_RAMP_F","#R036731_004_RAMP_V","#R036731_005_RAMP_F","#R036731_005_RAMP_V","#R036731_006_RAMP_F","#R036731_006_RAMP_V","#R036732_004_RAMP_F","#R036732_004_RAMP_V","#R036732_005_RAMP_F","#R036732_005_RAMP_V","#R036733_001_RAMP_F","#R036733_001_RAMP_V","#R036733_002_RAMP_F","#R036733_002_RAMP_V","#R036734_001_RAMP_F","#R036734_001_RAMP_V","#R036734_002_RAMP_F","#R036734_002_RAMP_V","#R036735_001_RAMP_F","#R036735_001_RAMP_V","#R036735_002_RAMP_F","#R036735_002_RAMP_V","#R036736_001_RAMP_F","#R036736_001_RAMP_V","#R036736_002_RAMP_F","#R036736_002_RAMP_V","#R036737_001_RAMP_F","#R036737_001_RAMP_V","#R036737_002_RAMP_F","#R036737_002_RAMP_V","#R036738_001_RAMP_F","#R036738_001_RAMP_V","#R036738_002_RAMP_F","#R036738_002_RAMP_V","#R036739_001_RAMP_F","#R036739_001_RAMP_V","#R036740_001_RAMP_F","#R036740_001_RAMP_V","#R036741_001_RAMP_F","#R036741_001_RAMP_V","#R036741_002_RAMP_F","#R036741_002_RAMP_V","#R036742_002_RAMP_F","#R036742_002_RAMP_V","#R036743_001_RAMP_F","#R036743_001_RAMP_V","#R036743_002_RAMP_F","#R036743_002_RAMP_V","#R036744_001_RAMP_F","#R036744_001_RAMP_V","#R036744_002_RAMP_F","#R036744_002_RAMP_V","#R036745_001_RAMP_F","#R036745_001_RAMP_V","#R036745_002_RAMP_F","#R036745_002_RAMP_V","#R036746_001_RAMP_F","#R036746_001_RAMP_V","#R036746_002_RAMP_F","#R036746_002_RAMP_V","#R036747_001_RAMP_F","#R036747_001_RAMP_V","#R036747_002_RAMP_F","#R036747_002_RAMP_V","#R036748_001_RAMP_F","#R036748_001_RAMP_V","#R036748_002_RAMP_F","#R036748_002_RAMP_V","#R036749_001_RAMP_F","#R036749_001_RAMP_V","#R036749_002_RAMP_F","#R036749_002_RAMP_V","#R036750_001_RAMP_F","#R036750_001_RAMP_V","#R036750_002_RAMP_F","#R036750_002_RAMP_V","#R036751_001_RAMP_F","#R036751_001_RAMP_V","#R036751_002_RAMP_F","#R036751_002_RAMP_V","#R036752_001_RAMP_F","#R036752_001_RAMP_V","#R036752_002_RAMP_F","#R036752_002_RAMP_V","#R036753_001_RAMP_F","#R036753_001_RAMP_V","#R036753_002_RAMP_F","#R036753_002_RAMP_V","#R036754_001_RAMP_F","#R036754_001_RAMP_V","#R036755_001_RAMP_F","#R036755_001_RAMP_V","#R036756_001_RAMP_F","#R036756_001_RAMP_V","#R036757_001_RAMP_F","#R036757_001_RAMP_V","#R036758_001_RAMP_F","#R036758_001_RAMP_V","#R036759_001_RAMP_F","#R036759_001_RAMP_V","#R036760_001_RAMP_F","#R036760_001_RAMP_V","#R036761_001_RAMP_F","#R036761_001_RAMP_V","#R036762_001_RAMP_F","#R036762_001_RAMP_V","#R036762_002_RAMP_F","#R036762_002_RAMP_V","#R036762_003_RAMP_F","#R036762_003_RAMP_V","#R036763_001_RAMP_F","#R036763_001_RAMP_V","#R036763_002_RAMP_F","#R036763_002_RAMP_V","#R036764_001_RAMP_F","#R036764_001_RAMP_V","#R036764_002_RAMP_F","#R036764_002_RAMP_V","#R036764_003_RAMP_F","#R036764_003_RAMP_V","#R036765_001_RAMP_F","#R036765_001_RAMP_V","#R036765_002_RAMP_F","#R036765_002_RAMP_V","#R036765_003_RAMP_F","#R036765_003_RAMP_V","#R036765_004_RAMP_F","#R036765_004_RAMP_V","#R036765_005_RAMP_F","#R036765_005_RAMP_V","#R036765_006_RAMP_F","#R036765_006_RAMP_V","#R036765_007_RAMP_F","#R036765_007_RAMP_V","#R036772_001_RAMP_F","#R036772_001_RAMP_V","#R036772_002_RAMP_F","#R036772_002_RAMP_V","#R036772_003_RAMP_F","#R036772_003_RAMP_V","#R036775_001_RAMP_F","#R036775_001_RAMP_V","#R036775_002_RAMP_F","#R036775_002_RAMP_V","#R036775_003_RAMP_F","#R036775_003_RAMP_V","#R036776_001_RAMP_F","#R036776_001_RAMP_V","#R036776_002_RAMP_F","#R036776_002_RAMP_V","#R036777_001_RAMP_F","#R036777_001_RAMP_V","#R036777_002_RAMP_F","#R036777_002_RAMP_V","#R036777_003_RAMP_F","#R036777_003_RAMP_V","#R036777_004_RAMP_F","#R036777_004_RAMP_V","#R036779_001_RAMP_F","#R036779_001_RAMP_V","#R036780_001_RAMP_F","#R036780_001_RAMP_V","#R036783_001_RAMP_F","#R036783_001_RAMP_V","#R036783_002_RAMP_F","#R036783_002_RAMP_V","#R036783_003_RAMP_F","#R036783_003_RAMP_V","#R036783_004_RAMP_F","#R036783_004_RAMP_V","#R036783_005_RAMP_F","#R036783_005_RAMP_V","#R036783_006_RAMP_F","#R036783_006_RAMP_V","#R036783_007_RAMP_F","#R036783_007_RAMP_V","#R036783_008_RAMP_F","#R036783_008_RAMP_V","#R036783_021_RAMP_F","#R036783_021_RAMP_V","#R036783_022_RAMP_F","#R036783_022_RAMP_V","#R036783_023_RAMP_F","#R036783_023_RAMP_V","#R036783_024_RAMP_F","#R036783_024_RAMP_V","#R036783_025_RAMP_F","#R036783_025_RAMP_V","#R036783_026_RAMP_F","#R036783_026_RAMP_V","#R036783_027_RAMP_F","#R036783_027_RAMP_V","#R036783_028_RAMP_F","#R036783_028_RAMP_V","#R036783_029_RAMP_F","#R036783_029_RAMP_V","#R036783_030_RAMP_F","#R036783_030_RAMP_V","#R036783_031_RAMP_F","#R036783_031_RAMP_V","#R036783_032_RAMP_F","#R036783_032_RAMP_V","#R036783_033_RAMP_F","#R036783_033_RAMP_V","#R036783_034_RAMP_F","#R036783_034_RAMP_V","#R036783_035_RAMP_F","#R036783_035_RAMP_V","#R036783_036_RAMP_F","#R036783_036_RAMP_V","#R036783_037_RAMP_F","#R036783_037_RAMP_V","#R036784_001_RAMP_F","#R036784_001_RAMP_V","#R036784_002_RAMP_F","#R036784_002_RAMP_V","#R036784_003_RAMP_F","#R036784_003_RAMP_V","#R036784_004_RAMP_F","#R036784_004_RAMP_V","#R036785_001_RAMP_F","#R036785_001_RAMP_V","#R036785_002_RAMP_F","#R036785_002_RAMP_V","#R036785_003_RAMP_F","#R036785_003_RAMP_V","#R036785_004_RAMP_F","#R036785_004_RAMP_V","#R036785_005_RAMP_F","#R036785_005_RAMP_V","#R036785_006_RAMP_F","#R036785_006_RAMP_V","#R036785_007_RAMP_F","#R036785_007_RAMP_V","#R036785_008_RAMP_F","#R036785_008_RAMP_V","#R036785_009_RAMP_F","#R036785_009_RAMP_V","#R036785_010_RAMP_F","#R036785_010_RAMP_V","#R036785_011_RAMP_F","#R036785_011_RAMP_V","#R036785_012_RAMP_F","#R036785_012_RAMP_V","#R036785_013_RAMP_F","#R036785_013_RAMP_V","#R036785_014_RAMP_F","#R036785_014_RAMP_V","#R036785_015_RAMP_F","#R036785_015_RAMP_V","#R036785_016_RAMP_F","#R036785_016_RAMP_V","#R036785_017_RAMP_F","#R036785_017_RAMP_V","#R036785_018_RAMP_F","#R036785_018_RAMP_V","#R036785_019_RAMP_F","#R036785_019_RAMP_V","#R036785_020_RAMP_F","#R036785_020_RAMP_V","#R036785_021_RAMP_F","#R036785_021_RAMP_V","#R036785_022_RAMP_F","#R036785_022_RAMP_V","#R036785_023_RAMP_F","#R036785_023_RAMP_V","#R036785_024_RAMP_F","#R036785_024_RAMP_V","#R036785_025_RAMP_F","#R036785_025_RAMP_V","#R036785_026_RAMP_F","#R036785_026_RAMP_V","#R036785_027_RAMP_F","#R036785_027_RAMP_V","#R036785_028_RAMP_F","#R036785_028_RAMP_V","#R036785_029_RAMP_F","#R036785_029_RAMP_V","#R036785_030_RAMP_F","#R036785_030_RAMP_V","#R036787_001_RAMP_F","#R036787_001_RAMP_V","#R036787_002_RAMP_F","#R036787_002_RAMP_V","#R036787_003_RAMP_F","#R036787_003_RAMP_V","#R036787_004_RAMP_F","#R036787_004_RAMP_V","#R036787_005_RAMP_F","#R036787_005_RAMP_V","#R036787_038_RAMP_F","#R036787_038_RAMP_V","#R036787_039_RAMP_F","#R036787_039_RAMP_V","#R036787_040_RAMP_F","#R036787_040_RAMP_V","#R036787_041_RAMP_F","#R036787_041_RAMP_V","#R036787_042_RAMP_F","#R036787_042_RAMP_V","#R036787_043_RAMP_F","#R036787_043_RAMP_V","#R036787_044_RAMP_F","#R036787_044_RAMP_V","#R036787_045_RAMP_F","#R036787_045_RAMP_V","#R036787_046_RAMP_F","#R036787_046_RAMP_V","#R036787_047_RAMP_F","#R036787_047_RAMP_V","#R036787_048_RAMP_F","#R036787_048_RAMP_V","#R036787_049_RAMP_F","#R036787_049_RAMP_V","#R036787_050_RAMP_F","#R036787_050_RAMP_V","#R036787_051_RAMP_F","#R036787_051_RAMP_V","#R036787_052_RAMP_F","#R036787_052_RAMP_V","#R036787_053_RAMP_F","#R036787_053_RAMP_V","#R036787_054_RAMP_F","#R036787_054_RAMP_V","#R036788_001_RAMP_F","#R036788_001_RAMP_V","#R036788_002_RAMP_F","#R036788_002_RAMP_V","#R036790_001_RAMP_F","#R036790_001_RAMP_V","#R036790_002_RAMP_F","#R036790_002_RAMP_V","#R036790_003_RAMP_F","#R036790_003_RAMP_V","#R036790_004_RAMP_F","#R036790_004_RAMP_V","#R036790_005_RAMP_F","#R036790_005_RAMP_V","#R036790_006_RAMP_F","#R036790_006_RAMP_V","#R036790_007_RAMP_F","#R036790_007_RAMP_V","#R036791_001_RAMP_F","#R036791_001_RAMP_V","#R036791_002_RAMP_F","#R036791_002_RAMP_V","#R036792_001_RAMP_F","#R036792_001_RAMP_V","#R036792_002_RAMP_F","#R036792_002_RAMP_V","#R036792_003_RAMP_F","#R036792_003_RAMP_V","#R036793_001_RAMP_F","#R036793_001_RAMP_V","#R036793_002_RAMP_F","#R036793_002_RAMP_V","#R036793_003_RAMP_F","#R036793_003_RAMP_V","#R036793_004_RAMP_F","#R036793_004_RAMP_V","#R036793_005_RAMP_F","#R036793_005_RAMP_V","#R036793_006_RAMP_F","#R036793_006_RAMP_V","#R036793_007_RAMP_F","#R036793_007_RAMP_V","#R036794_001_RAMP_F","#R036794_001_RAMP_V","#R036794_002_RAMP_F","#R036794_002_RAMP_V","#R036794_003_RAMP_F","#R036794_003_RAMP_V","#R036794_008_RAMP_F","#R036794_008_RAMP_V","#R036794_009_RAMP_F","#R036794_009_RAMP_V","#R036794_010_RAMP_F","#R036794_010_RAMP_V","#R036794_011_RAMP_F","#R036794_011_RAMP_V","#R036795_001_RAMP_F","#R036795_001_RAMP_V","#R036795_002_RAMP_F","#R036795_002_RAMP_V","#R036795_003_RAMP_F","#R036795_003_RAMP_V","#R036795_004_RAMP_F","#R036795_004_RAMP_V","#R036795_005_RAMP_F","#R036795_005_RAMP_V","#R036795_006_RAMP_F","#R036795_006_RAMP_V","#R036795_007_RAMP_F","#R036795_007_RAMP_V","#R036795_008_RAMP_F","#R036795_008_RAMP_V","#R036795_009_RAMP_F","#R036795_009_RAMP_V","#R036795_010_RAMP_F","#R036795_010_RAMP_V","#R036797_001_RAMP_F","#R036797_001_RAMP_V","#R036797_002_RAMP_F","#R036797_002_RAMP_V","#R036797_003_RAMP_F","#R036797_003_RAMP_V","#R036797_004_RAMP_F","#R036797_004_RAMP_V","#R036797_005_RAMP_F","#R036797_005_RAMP_V","#R036797_006_RAMP_F","#R036797_006_RAMP_V","#R036797_007_RAMP_F","#R036797_007_RAMP_V","#R036798_001_RAMP_F","#R036798_001_RAMP_V","#R036798_002_RAMP_F","#R036798_002_RAMP_V","#R036798_003_RAMP_F","#R036798_003_RAMP_V","#R036799_001_RAMP_F","#R036799_001_RAMP_V","#R036799_002_RAMP_F","#R036799_002_RAMP_V","#R036799_003_RAMP_F","#R036799_003_RAMP_V","#R036799_008_RAMP_F","#R036799_008_RAMP_V","#R036799_009_RAMP_F","#R036799_009_RAMP_V","#R036799_010_RAMP_F","#R036799_010_RAMP_V","#R036799_011_RAMP_F","#R036799_011_RAMP_V","#R036800_001_RAMP_F","#R036800_001_RAMP_V","#R036800_002_RAMP_F","#R036800_002_RAMP_V","#R036800_003_RAMP_F","#R036800_003_RAMP_V","#R036800_004_RAMP_F","#R036800_004_RAMP_V","#R036800_005_RAMP_F","#R036800_005_RAMP_V","#R036800_006_RAMP_F","#R036800_006_RAMP_V","#R036800_007_RAMP_F","#R036800_007_RAMP_V","#R036800_008_RAMP_F","#R036800_008_RAMP_V","#R036800_009_RAMP_F","#R036800_009_RAMP_V","#R036800_010_RAMP_F","#R036800_010_RAMP_V","#R036801_001_RAMP_F","#R036801_001_RAMP_V","#R036801_002_RAMP_F","#R036801_002_RAMP_V","#R036801_003_RAMP_F","#R036801_003_RAMP_V","#R036801_004_RAMP_F","#R036801_004_RAMP_V","#R036801_005_RAMP_F","#R036801_005_RAMP_V","#R036801_006_RAMP_F","#R036801_006_RAMP_V","#R036801_007_RAMP_F","#R036801_007_RAMP_V","#R036801_008_RAMP_F","#R036801_008_RAMP_V","#R036801_009_RAMP_F","#R036801_009_RAMP_V","#R036801_010_RAMP_F","#R036801_010_RAMP_V","#R036802_001_RAMP_F","#R036802_001_RAMP_V","#R036802_002_RAMP_F","#R036802_002_RAMP_V","#R036802_003_RAMP_F","#R036802_003_RAMP_V","#R036802_008_RAMP_F","#R036802_008_RAMP_V","#R036802_009_RAMP_F","#R036802_009_RAMP_V","#R036802_010_RAMP_F","#R036802_010_RAMP_V","#R036802_011_RAMP_F","#R036802_011_RAMP_V","#R036803_001_RAMP_F","#R036803_001_RAMP_V","#R036803_002_RAMP_V","CA_SYDS_59A889E5_1","DSNAP_LRHS_1","DSNAP_LRHS_2","T_V_NIL_FCSPS","V>>BELMLCB_BAML_TGML","V>>MLSY_GTDPT_MLSY","V>>MLSY_GTKT_MLSY","V>>MLSY_KTDPT_SYML","V>>MLSY_KTTX_SYML_2R","V>>MLSY_KTTX_SYML_5R","V>>MLSY_SHBE_SYML"],"is_categorical":true},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint factor","examples":["-0.156","0.151","-1","0.9963"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 03:10:57"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SPDINTERCONNECTORCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":48542,"decompressed_size_all_time":70116870},"visibility":"Public","trigger":"When a new connection point constraint is created"},"SPDREGIONCONSTRAINT":{"package":"GENERIC_CONSTRAINT","pdr_config":{"mappings":[{"REPORT_NAME":"SPDRC","REPORT_SUB_TYPE":"NULL","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.htm#96"],"comment":"SPDREGIONCONSTRAINT contains details on region demand constraint factors used in dispatch. SPDREGIONCONSTRAINTsets a LHS value.","description":"SPDREGIONCONSTRAINT is public data, and is available to all\nparticipants.\n\nSource\n\nSPDREGIONCONSTRAINT is updated whenever AEMO creates new regional\nconstraints.","primary_keys":["BIDTYPE","EFFECTIVEDATE","GENCONID","REGIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"BIDTYPE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"ENERGY\", \"LOWERREG\", \"LOWER60SEC\", \"RAISE5MIN\", \"LOWER5MIN\", \"LOWER6SEC\", \"RAISE60SEC\", \"RAISE6SEC\", \"RAISEREG\", \"RAISE1SEC\", \"LOWER1SEC\"])","mandatory":true,"comment":"AS Service type - relates to the BidType table; one of (RAISE6SEC, RAISE60SEC, RAISE5MIN, LOWER6SEC, LOWER60SEC, LOWER5MIN, RAISEREG, LOWERREG)","examples":null,"tips":["The meaning of these values is documented in the `BIDTYPES` table."],"enums":["ENERGY","LOWERREG","LOWER60SEC","RAISE5MIN","LOWER5MIN","LOWER6SEC","RAISE60SEC","RAISE6SEC","RAISEREG","RAISE1SEC","LOWER1SEC"]},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["2026/09/02 00:00:00"],"parse_csv_as_string":true,"is_date":true},"GENCONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Generic Constraint Identifier","examples":["#R036725_001_RAMP_F","#R036725_001_RAMP_V","#R036725_002_RAMP_F","#R036725_002_RAMP_V","#R036725_003_RAMP_F","#R036725_003_RAMP_V","#R036725_004_RAMP_F","#R036725_004_RAMP_V","#R036725_005_RAMP_F","#R036725_005_RAMP_V","#R036725_006_RAMP_F","#R036725_006_RAMP_V","#R036725_007_RAMP_F","#R036725_007_RAMP_V","#R036725_008_RAMP_F","#R036725_008_RAMP_V","#R036725_009_RAMP_F","#R036725_009_RAMP_V","F_S++TBTU_L5","F_S++TBTU_L6","F_S++TBTU_L60","F_S++TBTU_R5","F_S++TBTU_R6","F_S++TBTU_R60","F_S+TBTU_L1","F_S+TBTU_R1"],"is_categorical":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"FACTOR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint factor; one of (-1, 1)","examples":["1"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/02 02:06:53"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SPDREGIONCONSTRAINT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":963,"decompressed_size_all_time":1455580},"visibility":"Public","trigger":"When AEMO creates new regional constraints"},"SRA_CASH_SECURITY":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_CASH_SECURITY","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#172"],"comment":"Records the Cash Security details provided by an SRA Auction Participant as collateral to cover their Trading Position in the SRA market","primary_keys":["CASH_SECURITY_ID"],"columns":{"CASH_SECURITY_ID":{"sql_type":"VARCHAR2(36)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique identifier for the cash security.","is_categorical":true},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Authorised date","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"CASH_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Dollar amount of the cash security.","is_float":true},"CASH_SECURITY_RETURNED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Returned Dollar amount of the Cash Security.","is_float":true},"DELETIONDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Cash Security deleted date. For valid records, DeletionDate will be Null.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"FINALRETURNDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date the entire Cash Security amount was returned to the Auction Participant","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"INTEREST_ACCT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"The interest account ID for calculating the interest payment"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique identifier for the auction participant lodging the cash security.","is_categorical":true},"PROVISION_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date AEMO received the Cash Security deposit","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Private","trigger":"On record authorisation"},"SRA_FINANCIAL_AUCPAY_DETAIL":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_AUCPAY_DETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#196"],"comment":"Records details of the SRA financial auction payment","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The SRA contract identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"The source Region identifier for the Directional Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The identifier for the Directional Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Relevant Quarter of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"ALLOCATION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The percentage of the auction proceeds allocated to the TNSP on the directional link","is_float":true},"CLEARING_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Market Clearing Price of the Auction","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MAXIMUM_UNITS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Maximum Units Available for purchase in the Auction","is_float":true},"NET_PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The payment amount owed by AEMO, including shortfall","is_float":true},"PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The payment amount owed by AEMO before shortfall","is_float":true},"RESERVE_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The reserve price of the auction","is_float":true},"SHORTFALL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The shortfall amount","is_float":true},"SHORTFALL_UNITS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total number of units unpaid for in the auction","is_float":true},"UNITS_SOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total number of Allocated Units in the Auction, including Cancelled Units by an Auction Participant","is_float":true}},"visibility":"Private","trigger":"On successful posting of an SRA financials run"},"SRA_FINANCIAL_AUCPAY_SUM":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_AUCPAY_SUM","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#202"],"comment":"Records a summary of the Auction payment amount","primary_keys":["PARTICIPANTID","SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Relevant Quarter of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"GROSS_PROCEEDS_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total auction proceeds allocated to the TNSP","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"NET_PAYMENT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The net payment amount owed by AEMO to the TNSP","is_float":true},"SHORTFALL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The shortfall amount for in the SRA Quarter for the TNSP","is_float":true},"TOTAL_GROSS_PROCEEDS_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total auction proceeds allocated to all TNSPs in the SRA quarter","is_float":true},"TOTAL_SHORTFALL_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The total shortfall amount for in the SRA Quarter for all TNSPs","is_float":true}},"visibility":"Private","trigger":"On successful posting of an SRA financials run"},"SRA_FINANCIAL_AUC_MARDETAIL":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_AUC_MARDETAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#178"],"comment":"This table stores details of the margins returned to the participants.","primary_keys":["CASH_SECURITY_ID","PARTICIPANTID","SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"CASH_SECURITY_ID":{"sql_type":"VARCHAR2(36)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the cash security."},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The participant identifier.","is_categorical":true},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Relevant Quarter of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"RETURNED_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount returned to the Auction participant from this cash security.","is_float":true},"RETURNED_INTEREST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of interest applicable to the returned amount.","is_float":true}},"visibility":"Private","trigger":"On successful posting of an SRA financials run"},"SRA_FINANCIAL_AUC_MARGIN":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_AUC_MARGIN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#184"],"comment":"Records the amount of Cash Security required to be held by an Auction Participant after settlement","primary_keys":["PARTICIPANTID","SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier.","is_categorical":true},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Relevant Quarter of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"REQUIRED_MARGIN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of trading cash security required to be held by the participant after settlement.","is_float":true},"RETURNED_MARGIN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of cash security returned to the participant.","is_float":true},"RETURNED_MARGIN_INTEREST":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of interest applicable to returned cash security amounts.","is_float":true},"TOTAL_CASH_SECURITY":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Total cash security held by the participant.","is_float":true}},"visibility":"Private","trigger":"On successful posting of an SRA financials run"},"SRA_FINANCIAL_AUC_RECEIPTS":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_AUC_RECEIPTS","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#190"],"comment":"Records details of the Cancelled Units and their value for the Auction Participant","primary_keys":["CONTRACTID","FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"CONTRACTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The SRA contract identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"The source region identifier for the Directional Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The identifier for the Directional Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"Relevant Quarter of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","is_integer":true,"unsigned_int":true,"num_int_bits":16},"CLEARING_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The clearing price of the auction","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last changed date for the record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PROCEEDS_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Dollar value of Cancelled Units in the Auction for the Auction Participant","is_float":true},"RECEIPT_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The payment amount owed to AEMO","is_float":true},"UNITS_PURCHASED":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The number of units purchased","is_float":true},"UNITS_SOLD":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Units cancelled in the auction by the Auction participant.","is_float":true}},"visibility":"Private","trigger":"On successful posting of an SRA financials run"},"SRA_FINANCIAL_RUNTRK":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_FINANCIAL_RUNTRK","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#208"],"comment":"Records details of the settlement process for the cancellation and purchase of SRA Auction Units","primary_keys":["SRA_QUARTER","SRA_RUNNO","SRA_YEAR"],"columns":{"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Relevant Quarter of the Tranche","examples":["1","4"],"is_integer":true,"num_int_bits":16},"SRA_RUNNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":true,"comment":"SRA Run Number","examples":["2"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Year of the Tranche","examples":["2022","2026"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INTEREST_VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":false,"comment":"Version number of the interest component used in the payments run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2022/01/19 11:00:01"],"parse_csv_as_string":true,"is_s_datetime":true},"MAKEUP_VERSIONNO":{"sql_type":"NUMBER(3)","pl_type":"pl.UInt16","mandatory":false,"comment":"Version number of the makeup component used in the makeup run","is_integer":true,"unsigned_int":true,"num_int_bits":16},"POSTEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date/time the run was posted","examples":["2022/01/19 11:42:40"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time the run was triggered","examples":["2022/01/19 11:00:01"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The type of SRA run","examples":["RECEIPTS"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SRA_FINANCIAL_RUNTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":782,"decompressed_size_all_time":186390},"visibility":"Public","trigger":"On successful posting of an SRA financials run"},"SRA_OFFER_PRODUCT":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_OFFER_PRODUCT","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#214"],"comment":"Holds the Product details for each Offer File submitted by each SRA Auction Participant.","primary_keys":["AUCTIONID","LOADDATE","OPTIONID","PARTICIPANTID"],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique ID for each Auction date","is_categorical":true},"LOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date and time the system loaded the SRA Offer File","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"OPTIONID":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"Unique Product identifier (1 - 2000)","is_categorical":true,"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":false,"comment":"The source Region identifier for the Directional Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Directional Interconnector identifier","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"OFFER_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Offer price for this Product","is_float":true},"OFFER_QUANTITY":{"sql_type":"NUMBER(5)","pl_type":"pl.UInt32","mandatory":false,"comment":"The Offer quantity for this Product","is_integer":true,"unsigned_int":true,"num_int_bits":32},"TRANCHEID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"Tranche identifier","is_categorical":true}},"visibility":"Private","trigger":"On successful submission of an SRA offer file"},"SRA_OFFER_PROFILE":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_OFFER_PROFILE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#220"],"comment":"Holds the data of an SRA Auction Participant Offer Submission.","primary_keys":["AUCTIONID","LOADDATE","PARTICIPANTID"],"columns":{"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique ID for each Auction date","is_categorical":true},"LOADDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The date and time the system loaded the SRA Offer File","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"ACKFILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"SRA acknowledgment file name"},"FILENAME":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"SRA Offer File name"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The date and time this record was last modified","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TRANSACTIONID":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Transaction ID used for tracking"}},"visibility":"Private","trigger":"On successful submission of an SRA offer file"},"SRA_PRUDENTIAL_CASH_SECURITY":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_PRUDENTIAL_CASH_SECURITY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#226"],"comment":"Records the Cash Security details provided by an SRA Auction Participant as collateral to cover their Trading Position in the SRA market","primary_keys":["CASH_SECURITY_ID","PARTICIPANTID","PRUDENTIAL_DATE","PRUDENTIAL_RUNNO"],"columns":{"CASH_SECURITY_ID":{"sql_type":"VARCHAR2(36)","pl_type":"str","mandatory":true,"comment":"Unique identifier for the cash security."},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier for the Auction Participant lodging the Cash Security","is_categorical":true},"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The prudential date of the run.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PRUDENTIAL_RUNNO":{"sql_type":"NUMBER(8)","pl_type":"pl.UInt32","mandatory":true,"comment":"The run number for the prudential date","is_integer":true,"unsigned_int":true,"num_int_bits":32},"CASH_SECURITY_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Remaining Cash Security deposit available","is_float":true}},"visibility":"Private","trigger":"On authorisation of a cash security"},"SRA_PRUDENTIAL_COMP_POSITION":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_PRUDENTIAL_COMP_POSITION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#232"],"comment":"The prudential position of each company at the date and time of a specific prudential run","primary_keys":["PARTICIPANTID","PRUDENTIAL_DATE","PRUDENTIAL_RUNNO"],"columns":{"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The prudential date of the run.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PRUDENTIAL_RUNNO":{"sql_type":"NUMBER(8)","pl_type":"pl.UInt32","mandatory":true,"comment":"The run number for the prudential date","is_integer":true,"unsigned_int":true,"num_int_bits":32},"PRUDENTIAL_EXPOSURE_AMOUNT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Current Prudential Exposure of the Auction Participant including Offers","is_float":true},"TRADING_LIMIT":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The Trading Limit of the company at the time of the prudential run","is_float":true},"TRADING_MARGIN":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"The amount of Trading Margin available to the Auction Participant to trade (including Offered Units and Cancelled Units). Equal to TRADING_LIMIT minus PRUDENTIAL_EXPOSURE_AMOUNT.","is_float":true}},"visibility":"Private","trigger":"On successful completion of a prudential run"},"SRA_PRUDENTIAL_EXPOSURE":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_PRUDENTIAL_EXPOSURE","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#238"],"comment":"Records details of the Prudential Exposure of an SRA Auction Participant","primary_keys":["FROMREGIONID","INTERCONNECTORID","PARTICIPANTID","PRUDENTIAL_DATE","PRUDENTIAL_RUNNO","SRA_QUARTER","SRA_YEAR"],"columns":{"FROMREGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\"])","mandatory":true,"comment":"The source Region identifier for the Directional Interconnector","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1"]},"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"The identifier for the Directional Interconnector","is_categorical":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","is_categorical":true},"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The prudential date of the run.","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PRUDENTIAL_RUNNO":{"sql_type":"NUMBER(8)","pl_type":"pl.UInt32","mandatory":true,"comment":"The run number for the prudential date.","is_integer":true,"unsigned_int":true,"num_int_bits":32},"SRA_QUARTER":{"sql_type":"NUMBER(3)","pl_type":"pl.Int16","mandatory":true,"comment":"Contract Relevant Quarter","is_integer":true,"num_int_bits":16},"SRA_YEAR":{"sql_type":"NUMBER(4)","pl_type":"pl.UInt16","mandatory":true,"comment":"AEMO Contract Year number starting the week beginning 1 January","is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUCTIONID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Unique identifier for the Auction having the Offer. Has a null value when no Offer is made for the Relevant Quarter"},"AVERAGE_CANCELLATION_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated average cancellation price for product.","is_float":true},"AVERAGE_PURCHASE_PRICE":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Average Purchase Price for the Product","is_float":true},"CANCELLATION_VOLUME":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated cancellation volume for product.","is_float":true},"MAX_TRANCHE":{"sql_type":"NUMBER(2)","pl_type":"pl.UInt8","mandatory":false,"comment":"The largest Tranche where the Unit was either sold or offered. Used in the calculation of the Average Purchase Price for the Trading Position of the Product. The most recent Tranche where Units were cancelled or offered (if the Offer is below the Average Purchase Price)","is_integer":true,"unsigned_int":true,"num_int_bits":8},"OFFER_SUBMISSIONTIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp of the Offer File submitted by the Auction Participant. Has a null value when no Offer is made for the Relevant Quarter","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TRADING_POSITION":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated trading position for product.","is_float":true}},"visibility":"Private","trigger":"After each settlement run"},"SRA_PRUDENTIAL_RUN":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"SRA_PRUDENTIAL_RUN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#244"],"comment":"Records the prudential run details for each prudential date","primary_keys":["PRUDENTIAL_DATE","PRUDENTIAL_RUNNO"],"columns":{"PRUDENTIAL_DATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The prudential date of the run.","examples":["2022/10/12 04:00:05"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"PRUDENTIAL_RUNNO":{"sql_type":"NUMBER(8)","pl_type":"pl.UInt32","mandatory":true,"comment":"The prudential run number for the run","examples":["1","25"],"is_integer":true,"unsigned_int":true,"num_int_bits":32}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SRA_PRUDENTIAL_RUN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":21171,"decompressed_size_all_time":4355440},"visibility":"Public","trigger":"After each settlement run"},"SSM_CONTRACT_UNIT_AVAIL":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"CONTRACT_UNIT_AVAIL","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#1"],"comment":"The variable parameters associated to the Unit within an SSM Contract, allowing changes to the base contract values due to unit availabilities (e.g Maintenance, Outages).","primary_keys":["CONTRACT_ID","DUID","INTERVAL_DATETIME","VERSION_DATETIME"],"columns":{"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Contract Identifier"},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The starting Dispatch Interval for the availability change. This will be the active availability until the next INTERVAL_DATETIME record for this Contract and DUID.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date and Time of this record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ACTIVATION_LEAD_TIME":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"The expected maximum lead time for the system security service to be enabled from a non-operational state in minutes.","is_integer":true,"unsigned_int":true,"num_int_bits":32},"AVAILABLE":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Indicates if DUID is available for the INTERVAL_DATETIME (1 = True, 0 = False).","is_boolean":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MIN_DISPATCH_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Dispatch Target required for DUID to enable the contract.","is_float":true},"MIN_ENABLEMENT_DURATION":{"sql_type":"NUMBER(6,0)","pl_type":"pl.UInt32","mandatory":false,"comment":"Minimum duration a unit must be active to enable the contract in minutes.","is_integer":true,"unsigned_int":true,"num_int_bits":32},"UNIT_COUNT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Number of sub-units within a DUID that are available for enablement.","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private","trigger":"On change of the Contract Availability"},"SSM_ENABLEMENT_COSTS":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"ENABLEMENT_COSTS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#7"],"comment":"SSM Contract Enablement Costs for NEM","primary_keys":["ENABLEMENT_REASON","END_TRADINGDATE"],"columns":{"ENABLEMENT_REASON":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":true,"comment":"Primary Service type associated.","examples":["System Strength - Coefficient","System Strength - Combination","Transitional service - Type 1"],"is_categorical":true},"END_TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Trading Date of the end of the enablement","examples":["2026/08/31 00:00:00"],"parse_csv_as_string":true,"is_date":true},"ESTIMATED_COSTS":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Cost estimation for the service type.","examples":["236.94","0","1071","4337"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/09/01 12:00:06"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SSM_ENABLEMENT_COSTS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2025,"month":11},"last_month":{"year":2026,"month":9},"compressed_size_per_month":964,"decompressed_size_all_time":224760},"visibility":"Public","trigger":"Timed trigger once per day for previous day"},"SSM_ENABLEMENT_PERIOD":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"ENABLEMENT_PERIOD","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#13"],"comment":"SSM Contract Enablement Periods","primary_keys":["DUID","ENABLEMENT_START_INTERVAL","INSTRUCTION_ID"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["BARKIPS1","CETHANA","DEVILS_G","JBUTTERS","PPCCGT","REECE1","TUMUT3","YABULU","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"ENABLEMENT_START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The first Dispatch Interval the unit is enabled for SSM Services.","examples":["2026/09/01 04:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Instruction Identifier","examples":["CETHANA12609121125","CETHANA12609130405","CETHANA12609240355","CETHANA12609280840","CETHANA12609301035","DEVILS_G12609240945","DEVILS_G12609250940","DEVILS_G12609280810","INS44","INS45","INS47","INS48","INS49","INS53","INS54","INS55","INS56","INS57","INS58","INS60","INS61","INS63","INS64","INS65","INS66","INS68","INS69","INS70","INS73","INS74","INS75","INS84","INS85","INS86","INS87","INS89","INS90","INS92","INS94","INS95","INS97","INS98","JBUTTERS12609081200","JBUTTERS12609240725","JBUTTERS12609240735","REECE112609240935"]},"ENABLEMENT_END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last Dispatch Interval the unit is enabled for SSM Services.","examples":["2026/09/02 04:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ENABLEMENT_REASON":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Reason for the enablement.","examples":["System Strength - Coefficient","System Strength - Combination","Transitional service - Type 1"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/09/01 13:18:03"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23SSM_ENABLEMENT_PERIOD%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2025,"month":11},"last_month":{"year":2026,"month":9},"compressed_size_per_month":1567,"decompressed_size_all_time":474800},"visibility":"Public","trigger":"Timed trigger once per day for previous day"},"SSM_INDICATIVE_ROLL_DUID":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"INDICATIVE_ROLL_DUID","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#19"],"comment":"Indicative rolling DUID schedule provides notice of system security status to service providers/TNSP. The intent is to provide forewarning of possible enablement instruction that may be required","primary_keys":["CONTRACT_ID","DUID","INTERVAL_DATETIME","VERSION_DATETIME"],"columns":{"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Contract Identifier used to create enablement.","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Interval date time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Version date time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID_PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Primary recipient (SSM Service Provider) of enablement instruction.","is_categorical":true},"DUID_STATUS":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Scheduled pending, Scheduled approved, Instruction issued, Fulfilment, Available, Offline, Online, Outage"},"EQUIPMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit resource (for example, GENERATOR, LOAD, BIDIRECTIONAL, SYNCHRONOUS CONDENSER).","is_categorical":true},"INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique Instruction Identifier. Null where not applicable."},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MIN_DISPATCH_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Dispatch Target required for DUID to enable the contract.","is_float":true}},"visibility":"Private"},"SSM_INDICATIVE_ROLL_REGION":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"INDICATIVE_ROLL_REGION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#25"],"comment":"Indicative rolling Region schedule provides notice of system security status to service providers/TNSP. The intent is to provide the security strength status of a region","primary_keys":["INTERVAL_DATETIME","REGIONID","VERSION_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Interval date time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Version date time","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DUID_COUNT_FIRM":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Sum of firm units enabled for the region with confirmed enablement instruction(s) sent","is_integer":true,"unsigned_int":true,"num_int_bits":16},"DUID_COUNT_SPECULATIVE":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Sum of proposed units enabled for the region where enablement instruction(s) not sent","is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGION_STATUS":{"sql_type":"VARCHAR2(40)","pl_type":"str","mandatory":false,"comment":"Secure, Resolved, Not Secure"}},"visibility":"Public"},"SSM_INSTRUCTION":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"INSTRUCTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#31"],"comment":"An enablement of an SSM Contract that instructs a Dispatchable Unit is to provide a System Security Service.","primary_keys":["INSTRUCTION_ID","VERSION_DATETIME"],"columns":{"INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Instruction Identifier."},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Effective Date and Time of this record.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Unique Contract Identifier used to create enablement.","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"DUID_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Primary recipient (SSM Service Provider) of enablement instruction.","is_categorical":true},"END_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EQUIPMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit resource (for example, GENERATOR, LOAD, BIDIRECTIONAL, SYNCHRONOUS CONDENSER).","is_categorical":true},"INITIAL_INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique transaction identifier of initiating transaction if instruction related to an amendment or cancellation."},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MIN_DISPATCH_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Dispatch Target required for DUID to enable the contract. Value of zero means cancellation of instruction.","is_float":true},"SERVICE_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Requested Service to provide(System strength-combination,System strength-coefficient,NSCAS-voltage control,NSCAS,Inertia,Transitional service-type 1 MSL,Transitional service-type 1,Transitional service-type 2)."},"START_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The first Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TNSP_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Participant ID of TNSP if contract procurer is TNSP."},"UNIT_COUNT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Number of sub-units within a DUID that are required for enablement. Value of zero means cancellation of instruction.","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private","trigger":"On enablement of a contract to provide System Security Services"},"SSM_SCHEDULE":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"SCHEDULE","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#37"],"comment":"Scheduled SSM contract enablements.","primary_keys":["INSTRUCTION_ID"],"columns":{"INSTRUCTION_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":true,"comment":"Unique Instruction Identifier"},"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"str","mandatory":false,"comment":"Unique Contract Identifier used to create enablement."},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"DUID_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Primary recipient (SSM Service Provider)","is_categorical":true},"END_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"EQUIPMENT_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Dispatchable Unit resource (for example, GENERATOR, LOAD, BIDIRECTIONAL, SYNCHRONOUS CONDENSER).","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"MIN_DISPATCH_MW":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Minimum Dispatch Target required for DUID to enable the contract.","is_float":true},"SERVICE_TYPE":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"Requested Service to provide(System strength-combination,System strength-coefficient,NSCAS-voltage control,NSCAS,Inertia,Transitional service-type 1 MSL,Transitional service-type 1,Transitional service-type 2)."},"START_INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The first Dispatch Interval of the enablement.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TNSP_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Participant ID of TNSP if contract procurer is TNSP.","is_categorical":true},"UNIT_COUNT":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Number of sub-units within a DUID that are required for enablement.","is_integer":true,"unsigned_int":true,"num_int_bits":16}},"visibility":"Private","trigger":"Timed trigger once per day for previous day"},"SSM_SCHEDULED_AVAILABILITY":{"package":"SYSTEM_SECURITY_MANAGEMENT","pdr_config":{"mappings":[{"REPORT_NAME":"SSM","REPORT_SUB_TYPE":"SCHEDULED_AVAILABILITY","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec81.htm#43"],"comment":"Scheduled SSM availability","primary_keys":["AVAILABLE_START_INTERVAL","CONTRACT_ID","DUID"],"columns":{"AVAILABLE_START_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The first Dispatch Interval the unit is available.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CONTRACT_ID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique Contract Identifier","is_categorical":true},"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"AVAILABLE_END_INTERVAL":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"The last Dispatch Interval the unit is available.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last time record was changed.","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TNSP_PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"TNSP Participant ID","is_categorical":true}},"visibility":"Private","trigger":"Timed trigger once per week for the previous week"},"STADUALLOC":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"STADUALLOC","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#235"],"comment":"STADUALLOC sets out details on the allocation of dispatchable units to particular sites or stations.","description":"STADUALLOC is public data, and is available to all participants.\n\nSource\n\nSTADUALLOC is updated whenever there is a station configuration change\nor new unit registration.","primary_keys":["DUID","EFFECTIVEDATE","STATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"],["STATIONID","EFFECTIVEDATE","VERSIONNO"],["DUID"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["ADPBA1G","ADPBA1L","ADPMH1","ADPPV1","ADPPV2","ADPPV3","AGLHAL","AGLNOW1","AGLSITA1","AGLSOM","AMCORGR","ANGAS1","ANGAS2","ANGAST1","APPIN","APS","ARWF1","ASENGV01","ASENGY01","ASNACTW1","ASNAES1","ASNBRL1","ASNSEL2","ASPAPM01","ASQEEV1","ASRMGE01","ASRMGE02","ASRMGE03","ASSDE1","ASSEL1","ASSERDV1","ASSSN1","ASTFG1V1","ASTHYD1","ASVIEL2","AS_NSW1","AVLSF1","AWABAREF","BAKING1","BALBG1","BALBL1","BANGOWF1","BANGOWF2","BANKSPT1","BANN1","BAPS","BARCALDN","BARCSF1","BARKIPS1","BARRON-1","BARRON-2","BLUEGSF1","BLUFF1","BLULAKE1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOLIVAR1","BOLIVPS1","BOMENSF1","BOWWBA1G","BOWWBA1L","BOWWDG1","BOWWPV1","BPLANDF1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BROADMDW","BROKENH1","BROOKLYN","BROWNMT","BRYB1WF1","BRYB2WF2","BULBESG1","BULBESL1","BULGANA1","BURRIN","BUTLERSG","BWTR1","CALLNL1","CALLNL2","CALLNL3","CALLNL4","CALL_A_1","CALL_A_2","CALL_A_3","CALL_A_4","CALL_B_1","CALL_B_2","CAPBES1G","CAPBES1L","CAPTL_WF","CATA_1","CATA_2","CATHROCK","CBWF1","CBWWBA1G","CBWWBA1L","CBWWBG1","CBWWDG1","CBWWDG2","CBWWPV1","CBWWPV2","CESF1","CETHANA","CHALLHWF","CHBESSG1","CHBESSL1","CHILDSF1","CHPSTWF1","CHYTWF1","CLARESF1","CLAYTON","CLEMGPWF","CLERMSF1","CLOVER","CLOVER1","CLOVER2","CLUNY","CNUNDAWF","CODRNGTON","COHUNSF1","COLEASF1","COLNSNL1","COLNSV_1","COLNSV_2","COLNSV_3","COLNSV_4","COLNSV_5","COLWF01","CPP_3","CPP_4","DG_SA1","DG_TAS1","DG_VIC1","DIAPURWF1","DLNKNSW","DLNKQLD","DPNTBG1","DPNTBL1","DRACAN1","DRACAV1","DRAESN1","DRAESN3","DREXMN01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DROZVP01","DRSHVN01","DRSHVS01","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDE01","DRXNQX01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT1","DRYCGT2","DRYCGT3","DRYCNL","DRYCNL3","DULAWF1","DUNDWF1","DUNDWF2","DUNDWF3","EASTCRK","EASTCRK2","EDENVSF1","EDLRGNRD","EILDON1","EILDON2","EILDON3","ELAINWF1","EMERASF1","GANGARR1","GANNBG1","GANNBL1","GANNSF1","GEORGTN1","GEORGTN2","GERMCRK","GLADNL1","GLBWNHYD","GLENMAG1","GLENNCRK","GLENSF1","GLRWNSF1","GNNDHSF1","GOONSF1","GORDON","GORDON1","GORDON2","GORDON3","GOVILLB1","GRANGEAV","GRANWF1","GRIFSF1","GROSV1","GROSV2","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GSWF1A","GSWF1B1","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUTH-1","GUTH-2","HALAMRD1","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HBESSG1","HBESSL1","HDWF1","HDWF2","HDWF3","HEPWIND1","HEZ","HEZ1","HIGHBRY1","HILLSTN1","HLMSEW01","HPRG1","HPRL1","HUGSF1","HUMENSW","HUMEV","HVGTS","HVWWBA1G","HVWWBA1L","HVWWPV1","HWPNL1","HWPS1","HWPS2","HWPS3","HWPS4","HWPS5","HWPS6","HWPS7","HWPS8","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JNDABNE1","JOUNAMA1","JUNEESF1","KABANWF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KAREEYA5","KARSF1","KARYNL1","KEEPIT","KEPBG1","KEPBL1","KEPSF1","KEPWF1","KIAMSF1","KIATAWF1","KINCUM1","KKGTS","KPP_1","KRCCOGEN","KSP1","LADBROK1","LADBROK2","LBBG1","LBBL1","LD01","LD02","LD03","LD04","LEMONTME","LEM_WIL","LGAPWF1","LGAPWF2","LIDDNL1","LILYSF1","LIMOSF11","LIMOSF21","LI_WY_CA","L_W_CNL1","MARIAN","MAROOWF1","MARYRSF1","MBAHNTH","MBPS2PV1","MCKAY1","MCKAY2","MEADOWB2","MEADOWBK","METZSF1","MEWF1","MIDDLSF1","MIDLDPS1","MINTARO","MINTNL1","MLLFGEF1","MLSP1","MLWF1","MM3","MM4","MMNL1","MOLNGSF1","MOORAWF1","MORANBAH","MOREESF1","MORNW","MORTLK11","MORTLK12","MOUSF1","MP1","MP2","MPNL1","MPP_1","MPP_2","MRTLSWF1","MSTUART1","MSTUART2","WYA252B1","WYB252B1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Station Identifier","examples":["ADP","AGLHAL","AGLNOW1","AGLSITA","AGLSOM","AMCORGR","ANGASTON","APPIN","APS","ARWF","ASENGV01","ASENGY01","ASNACTEW","ASNAES","ASNBRL","ASNSEL2","ASPAPM01","ASQEEV1","ASRMGE01","ASRMGE02","ASRMGE03","ASSDE","ASSEL","ASSERDV1","ASSSN","ASTFG1","ASTHYD1","ASVIEL2","AS_NSW1","AVLSF","AWABAREF","B2PS","BAKING","BALBESS","BANGOWF","BANGOWF2","BANKSPT","BANNSP","BAPS","BARCALDN","BARCSF","BARKIPS","BARRON","BLUEGSF","BLUFF","BLULAKE","BNGSF1","BNGSF2","BOCOROCK","BODWF","BOLIVAR","BOLIVPS","BOMENSF","BPLANDF","BRAEMARA","BROADMDW","BROKENH","BROOKLYN","BROWNMT","BRYB1WF","BRYB2WF","BULGANA","BURRIN","BUTLERSG","BWTR1","CALLIDE","CALLIDEC","CALLIDEC1","CANUNDA1","CAPTL_WF","CATHROCK","CBESS","CBWF","CBWW","CESF","CETHANA","CHALLWF","CHBESS","CHILDSF","CHPSTWF","CHYTWF","CLARESF","CLAYTON","CLEMGPWF","CLERMSF","CLOVER","CLUNY","CODRGTON","COHUNA","COLEASF","COLLECWF","COLNSV","DG_SA1","DG_TAS1","DG_VIC1","DIAPURWF","DIRECTLINK","DPNTBESS","DRACAN1","DRACAV1","DRAESN1","DRAESN3","DREXMN01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DROZVP01","DRSHVN01","DRSHVS01","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDE01","DRXNQX01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT","DULAWF1","DUNDWF","EASTCRK","EASTCRK2","EDENVSF","EDLRGNRD","EILDON","EILDONPD","ELAINEWF","EMERASF","G/STONE","GANGARRI","GANNBESS","GANNSF","GEORGTWN","GERMCRK","GLBWNHYD","GLENMAGG","GLENNCRK","GLENSF","GLRWNSF","GNNDHSF","GOONSF","GORDON","GRANGEAV","GRANWF","GRIFSF","GROSV1","GROSV2","GSWF1A","GSWF1B","GULLRGWF","GUNNING","GUTHEGA","HALAMRD","HALLWF","HALLWF2","HAMISF","HAUGHT1","HAYMSF","HAZEL","HBESS1","HEPWIND","HEZ","HEZ1","HIGHBRY","HILLSTN","HLMSEW01","HORNSDAL","HORNSDAL2","HORNSDAL3","HORNSDPR","HUGSF","HUMENSW","HUMEV","HUNTVGT","HVWW","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEERA","JEERB","JEMALNG","JNDSHPS","JOUNAMA","JUNEESF","KABANWF","KAREEYA","KARSF","KEEPIT","KEP","KIAMSF","KIATAWF","KINCUMB","KOGANCK","KOOLKHAN","KRCCOGEN","KSP1","LADBROKE","LBBESS","LEM_WIL","LGAPWF1","LIDDELL","LILYVASF","LIMOSF1","LIMOSF2","LI_WY_CA","MARIAN","MAROOWF1","MARYRSF","MBAHNTH","MBPS2","MCKAY","MEADOWBK","METZSF","MEWF","MIDDLESF","MIDLDPS","MILLMERN","MINTARO","MLLFGEF","MLSP","MLWF","MM","MOLNGSF","MOORAWF","MORANBAH","MOREESF","MORNW","MORTLK","MOUSF","MP","MRTLSWF","MSTUART"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of this record for the effective date","examples":["1","51"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/11/02 12:11:30"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STADUALLOC%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":31637,"decompressed_size_all_time":32391840},"visibility":"Public","trigger":"When there is a station configuration change or new unit registration"},"STATION":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"STATION","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#248"],"comment":"STATION sets out valid station identifiers.","description":"STATION is public data, and is available to all participants.\n\nSource\n\nSTATION updates whenever there is a station configuration change or new\nunit registration.","primary_keys":["STATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Station Identifier","examples":["ADP","AGLHAL","AGLNOW1","AGLSITA","AGLSOM","ALDGASF","AMCORGR","ANGASTON","APPIN","APS","ARWF","ASACLE01","ASDEVI01","ASDLBY01","ASENGV01","ASENGY01","ASGENE01","ASNACTEW","ASNAES","ASNBRL","ASNSEL2","ASPAPM01","ASPBSC01","ASPSTV01","ASQEEV1","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ASSDE","ASSEL","ASSERDV1","ASSSN","ASTFG1","ASTHYD1","ASVIEL2","AS_NSW1","AVLSF","AWABAREF","B2PS","BAKING","BALBESS","BANGOWF","BANGOWF2","BANKSPT","BANNSP","BAPS","BARCALDN","BARCSF","BARKIPS","BARRON","BASSLINK","BASTYAN","BAYSW","BBASEHOS","BBATTERY","BBDISEL1","BBP31","BDONGHYD","BELLBAY","BERWICK","BERYLSF","BHASZINC","BHBESS","BHILLGT","BHWF","BLOWER","BLUEGSF","BLUFF","BLULAKE","BLYTHB","BNGSF1","BNGSF2","BOCOROCK","BODWF","BOLIVAR","BOLIVPS","BOMENSF","BPLANDF","BRAEMARA","BRNDBES","BROADMDW","BROKENH","BROOKLYN","BROWNMT","BRYB1WF","BRYB2WF","BSOUNDSF","BULGANA","BUNGAMB1","BURRIN","BUSF","BUTLERSG","BWTR1","CALLIDE","CALLIDEC","CALLIDEC1","CANUNDA1","CAPTL_WF","CATHROCK","CBESS","CBWF","CBWW","CESF","CETHANA","CGBESS","CHALLWF","CHBESS","CHILDSF","CHPSTWF","CHYTWF","CLARESF","CLAYTON","CLEMGPWF","CLERMSF","CLOVER","CLRKCRWF","CLUNY","CODRGTON","COHUNA","COLEASF","COLLECWF","COLNSV","COLONGRA","COLUMSF","CONDONG1","COOPGWF","COPTNHYD","CORIO","CPSA","CROOKWF2","CROOKWF3","CROWLWF","CRURWF","CRWARPSF","CRWASF","CSPVPS","CTHLWF","CULLERIN","CUSF","DAANDINE","DALNTH","DARLSF","DARTM","DAYDSF","DDPS1","DDSF","DEIBDL","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIAPURWF","DIRECTLINK","DPNTBESS","DRACAN1","DRACAV1","DRAESN1","DRAESN3","DRAESS1","DRBRLV01","DREXMN01","DRFIIN01","DRFIIN02","DRGBND01","DRGBND02","DRGBND03","DRGBND04","DRHTVP01","DRHTVP03","DROZVP01","DROZVP02","DROZVP03","DRPSTQ01","DRPSTV01","DRSHVN01","DRSHVN02","DRSHVQ01","DRSHVS01","DRSHVS02","DRVIOT01","DRVIOT02","DRVIOT03","DRVIOT04","DRVIOT05","DRVIOT06","DRVIOT07","DRVISB01","DRXNAD01","DRXNAE01","DRXNDA01","DRXNDA02","DRXNDA03","DRXNDA04","DRXNDB04","DRXNDE01","DRXNDJ01","DRXNDW01","DRXNFF01","DRXNFS01","DRXNQX01","DRXNSS01","DRXNTM02","DRXNVS01","DRXQDA01","DRXQQE01","DRXSQS01","DRXVAE01","DRXVDJ01","DRXVDP01","DRXVDX01","DRXVQP01","DRXVQX01","DRXVQX02","DRYCGT","DULAWF1","DUNDWF","EASTCRK","EASTCRK2","EDENVSF","EDLRGNRD","EILDON","EILDONPD","ELAINEWF","EMERASF","ENERGYB","ENOCNSW","ENOCQLD","ENOCSA","ENOCSTA","ERARING","ERBESS","ERBESS2","ERGT01","ERG_AS","FARLEIGH","FINLEYSF","FIRMSLDC","FISHER","FLYCRKWF","FNWF","FSWF","G/STONE","GANGARRI","GANNBESS","GANNSF","GEORGTWN","GERMCRK","GESF","GIRGSF","GLBWNHYD","GLENMAGG","GLENNCRK","GLENSF","GLRWNSF","GNNDHSF","GOESF","GOONSF","GORDON","GPWFEAST","GPWFWEST","GRANGEAV","GRANWF","GREENB","GRIFSF","GROSV1","GROSV2","GSWF1A","GSWF1B","GULLRGWF","GUNNING","GUSF","GUTHEGA","HALAMRD","HALLWF","HALLWF2","HAMISF","HASTING","HAUGHT1","HAUGHTSS","HAYMSF","HAZEL","HBESS1","HDWF","HEPWIND","HEZ","HEZ1","HIGHBRY","HILLSTN","HLMSEW01","HORNSDAL","HORNSDAL2","HORNSDAL3","HORNSDPR","HUGSF","HUMENSW","HUMEV","HUNTER","HUNTVGT","HVWW","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEERA","JEERB","JEMALNG","JINDABYNE","JNDSHPS","JOUNAMA","JUNEESF","KABANWF","KAREEYA","KARSF","KEEPIT","KEP","KERNGSP1","KIAMSF","KIATAWF","KIDSPHES","KINCUMB","KINGASF","KOGANCK","KOOLKHAN","KOORBESS","KRCCOGEN","KSP1","LADBROKE","LANCASF1","LBBESS","LDBESS","LEM_WIL","LGAPWF1","LIDDELL","LILYVASF","LIMBESS","LIMOSF1","LIMOSF2","LI_WY_CA","LKBONNY1","LKBONNY3","LKBONNY_2","LK_ECHO","LNGS","LONGFORD","LONSDALE","LOYYANGA","LOYYB","LRSF","LUCAS2S2","LUCASHGT","LVES","LYGS","MACARTH","MACKAY","MACKNADE","MACKNTSH","MANNSF2","MANNUMB1","MANSLR","MAPS2","MAPS3","MARIAN","MAROOWF1","MARYRSF","MBAHNTH","MBPS2","MCINTYR","MCKAY","MEADOWBK","MELBRL","METZSF","MEWF","MIDDLESF","MIDLDPS","MILLMERN","MINTARO","MLBESS","MLLFGEF","MLSP","MLWF","MM","MOKOANSF","MOLNGSF","MOORAWF","MORANBAH","MOREESF","MORNW","MORTLK","MOUSF","MP","MREHA1","MREHA2","MREHA3","MRNBESS","MRTLSWF","MSTUART","MTGELWF","MTMERCER","MTMILLAR","MUCRKSF","MULGRAVE","MURLINKP","MURRAY","MURRAY1","MURRAY2","MUSF","MUSSELRO","MUWAWF","MUWAWF2","MWPS1","MWPS2","MWPS3","MWPS4","NASF","NBHWF","NESBESS","NEVERSF","NEWENGSF","NEWPORT","NINEWIL","NORTHGT","NORTHP","NPPPPS","NUMURKSF","NYNGAN","OAKEY","OAKEY1SF","OAKEY2SF","OAKLAND","OAKY2","OCPS","ORABESS","OSBORNE","PALOONA","PAREP","PEDLER","PIBESS","PINDARI","PIONEER","PLANECRK","PLAYF","PLBESS1","PLEYSTOW","PMATTAEP","PORTLAND","PORTLATT","PORTLCN","PORTWF","PSF","PTH","PTINA110","PTINA220","QBYNBESS","QUARANTN","QUERIVER","QUORNPSH","RACOMIL","RANGBESS","RCOURSE","REDBANK1","REECE","REMOUNT","REPULSE","RESS1","RESS2","ROCHEDAL","ROMA","ROWALLAN","ROYALLA","RPCG","RRSF","RT_NSW1","RT_QLD1","RT_SA1","RT_TAS1","RT_VIC1","RUBICON","RUGBYR","RYANCWF","RYEPARK","SALTCRK","SAPHWF1","SATGN","SATGS","SEBSF","SHEP1","SHOALC","SHOALHAV","SITHE","SKSF","SMCSF","SMFBESS1","SMFBESS2","SMTHBESS","SNAPPER","SNB","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYP","SNUG","SNWYGJP2","SOMERSET","SRSF","STABESS","STANVAC","STANWELL","STAPYLTON","STARFHILL","STGEORGE","STHBKTEC","STHJST","STOCKYD","STPN1","STUBBSF1","STUBBSF2","STWF","SUNCOAST","SUNRSF","SUNSHINE","SUNTPSF","SVALE","SWANBANK","SWANBKBF","SYMEX","TABMILL2","TAHMOOR","TALLAWAR","TARALGA","TARONG","TARONGN","TARRALEA","TATIARA","TATURA","TB2HYB","TB3BESS","TBLAND","TBSF","TEATREE","TEMPBESS","TERALBA","TERMSTOR","TGNSS","THEDROP","TIBESS","TIMWEST","TITREE","TOMAGO","TOORAWF","TORRIS","TOWER","TREVALLN","TRGBESS","TRIBUTE","TRNGBESS","TULLYSM","TUMUT1","TUMUT2","TUMUT3","TUNGATIN","TVCCPS","ULPBESS","URANQ","UWF","UWS","VALDORA","VBB","VICMILL","VICSMLT","VP","VPGS","VSNEL2","VSNSN1","VSQHT1","VSSAE1","VSSEL1","VSSSE1","VSSSH1","VSVEL2","WAGGNSF","WALGBESS","WAMBOWF1","WAMBOWF2","WANDBESS","WANDSF","WARWSF1","WARWSF2","WATERLWF","WAUBRAWF","WCLASS","WDBESS","WDGPH","WDLNGN","WELLINSF","WELLNTH","WEMENSF1","WESTCBT","WESTILLA","WG","WGULLY","WGWF","WHIT1","WHITSF","WILGAPK","WILGAPKB","WILLBESS","WILLHOV","WINDHILL","WINGF1","WINGF2","WINTONSF","WIVENHOE","WIVENSH","WKIEWA","WLWLSF1","WLWLSF2","WNSF","WOLARSF","WOLLERT","WONWP","WOODLWN","WOOLGSF","WOOLNTH1","WOOLOOGA","WOOREEN","WOYWOY","WPWF","WRSF1","WRWF1","WSTWYSF","WTAHBESS","WUNUSF","WW","WYANGALA","WYANGALB","WYASF","WYNDW","YABULU","YALLOURN","YAMBUK","YARANSF","YARWUN","YATSF","YAWWF","YENDONWF","YSWF","YWNGAHYD"],"is_categorical":true},"ADDRESS1":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Station Address","examples":["\"Bellview\"","'The Willows' Road","1 Hargreaves St","1 Hort Street","1 Power House Road","1 Powerhouse Road","1 Zinc Avenue","10 Old Leumeah Road","100 Gap Road","100 Refinery Road","101 East And West Road","1020-744 Geggies Rd","1039 Banana Bridge Road","1039 Gadsbys Road","1043 Koonoona Road","10793 Kidman Way","1080 Buffalo - Waratah Road","1083 Mason Road","11 Bayview Road","1100-1152 Christies Road","1106 Park Road","112 LONG POINT ROAD WEST","114 Booth Rd","115 McMahon Road","1154 Connewarren Lane","116 Lee Road","117 Pacific Highway","1185 Mt Stuart Road","119 Grahams Road","120 Hoff Road","1225 Nanango Road","123 Eleven Mile Creek Road","124 Princes Highway","124 South West Angle Road","128 GRAHAM ROAD","12871 Warrego Highway","130 HUME HIGHWAY","132 Mine Road","1360 Twelve Mile Road","14 Woodruff St","1409 Newell Highway","1475 Tarago Road","1496 Wide Bay Highway","153 Woodhouselee Road","1558 Carbean Road","157 Windmill Road","1580-1706 Wide Bay Highway","16 Chrysler Road","16 Mile Hall Road","160 Bolong Road","160 Round Mountain Road","162 Bishops Bridge Road","1645 Hamilton-Port Fairy Rd","168 Sturgess-Baking Board Road","17 Thornells Road","17235 Dawson Highway","1725 Elizabeth Dr","174 GARDNER ROAD","180 Phillip Highway","1827 Springmount Road","1830 Princetown Rd","1862 Princetown Rd","1869 Packham Drive","188 Canalla Road","189 WHITWOOD ROAD, NEW CHUM","197 Macclesfield Road","19L Sheraton Road","200 Daldy Road","200 Old Wallgrove Road","2040 Ballan-Daylesford Rd","2043 Glenmore Road","2111 Junction Road","2123 Maryborough Hervey Bay Road","215 BURNSIDE ROAD","215 Mannum Road","2165 Kogan-Condamine Road","219 Diapur Lawloit Road","228 Blands Lane","23 Killafaddy Rd","23-29 Nixon Road","2340 Belgravia Road","236 Grange Avenue","239 Maroondah Hwy","24 Artarmon Road","245 Beryl Road","255 Savernake Road","26 Cribb Road","261 Lime Kiln Road","27265 Bruce Highway","274 Hallam Road","275 Richardson Road","27566 Warrego Highway","280 Storriers Lane","286 Shelford-Mt Mercer Rd","290 Kerwick's Road","2917 Ballan Meredith Road (North)","298 Eumungerie Road","30 Bonds Lane","300 Mortons Lane","304 Boyles Road","305 Swanbank Road","315 Donald Ross Drive","32 Rossmans Road","3208 Fitzroy Development Road","33 Herbert Place","336 Donald Ross Drive","34017 Warrego Highway","341 Kent-Tobin Road","346 Old Sydney Road","349 Brown Plains Road","35 GRAND AVENUE","3757 Yanga Way","378 Kirchner Rd","379 Goorambat-Chesney Road","38 Glenrowan West Road","397 Alpha Bypass Road","397 And 519 Power Station Road","397 Kingaroy Barkers Creek Road","408 Wunghnu Road","411 ROGHAN ROAD","42 Pat Meredith Drive","44 Old Echuca Road","45-135 Bridge In Road","458-460 Winton-Glenrowan Road","465 Blue Springs Road","466 Yeungroon-Coonooer Road","499 Mugga Lane Jerrabomberra","5 Battery Court","500 Doering Road","500 Graywood Siding Road","546 Verwood Road","550 Reillys Pit Road","58 Ortlipp Road","584 Gadsby's Road And 191 Bakers Road","6 Herbert Place","619 Collector Road","631 Spring Flat Road","633 Rugby Run Road","6444 Goolma Road","6916 Goolma Road","6945 Goolma Rd","70 Littles Lane","73-83 Eastern Road","730 Dhurringile Road","739 Padgetts Lane","75 Eurolee Road","76-82 Pinnacles Place","765 Orange Grove Road","77-347 Holden Road","780 Woolsthorpe-Heywood Road","8 Greenfield Parade","8 HULETT STREET","82, 124, 196 Shadforth Road","83 & 85 Kremzow Road","830 Sidebottoms Road","909 Kerang-Leitchville Road","909 Suntop Road","909 Yandina Coolum Road","96 Maree Road","961 Andrews Lane","975 Hanson Road","ALCOA AUSTRALIA LIMITED","Aarons Pass Road","Adjacent To The Pelican Point Power Station At Outer Harbour","Adri Birkenhead","Ailsa Wheat Rd","Alisa Wheet Road","Anzac Road","Argent Road","Argyle Road","Atkinsons Road","Augusta Highway","Avon Lake Road","Avonlie Solar Farm, Muntz Road","BARTONS LANE","BASTYAN","BAYSWATER","BENDEELA ROAD","BUTLERSG","Ballarat Terminal Station","Barton's Lane","Bartons Lane","Bartons Road Pk 2.2","Base Hospital Campus","Bayley Park Road","Benambra Road","Berwick Landfill","Biddlecomb Road","Big Ridge Road","Birkins Road","Block 1471, Angle Crossing Road,Tuggeranong","Block 187 Mountain Road","Bodangora Wind Farm, Gillinghall Road","Brisbane Valley Highway","Broadmeadows Landfill","Brodribb Road","Burley Rd","Burrrendong Dam Via Wellington","C/- ERGON ENERGY","C/- ETSA POWER ADELAIDE","C/- SECV","CALLIDE","CAMPBELL STREET","CASINO ROAD","CATHEDRAL ROCKS WIND FARM","CETHANA","CLUNY","CNR VICTORIA ROAD & JAMES RUSE DRIVE","C\\- CS ENERGY","Calder Highway Ouyen, Old Kia Road","Camden Park, 50758 Landsborough Highway","Canunda Frontage Road","Cape Portland Road","Centennial Coal","Central Highlands","Champions Way","Chepstowe-Pittong Road","Clarke Road","Clayton Landfill","Cnr Kearney Warrego Highway","Cnr Tapps Lane & Terang Mortlake Rd","Copeton Dam Via Inverell","Corner Coker Dam Road And Salisbury South Road","Corner Mannum Road And Patricks Road","Corner Of Dobie Road And Atkinson Road","Corner Of Pittsworth-Tummaville Road And Yarranlea-Murlaggan Road","Corner Of Power Rd And Templers Rd","Corner Of Roach Rd & Yarranlea-Murlaggan Road","Corner Of Taralga Road And Old Show Ground Road","Corner Of The Cut Line And Yanga Way Hwy","DARTMOUTH","DEVILS GATE","DLWC OFFICE, PO BOX 50","DRUMMOND DRIVE","DRY CREEK","Dalton Road","Dartmonth Rd","Daydream Mine Road","Diamondy Road","DigiCo East","Douglas Park Drive","EAST TAMAR HIGHWAY","EASTERN ROAD","East Tamar Highway","Eastern Creek Waste Management Centre","Ergon Substation","Erinvale Property, Redlands Road","Ernst St","Errowanbang Rd, Errowanbang","Eyre Highway","FARLEIGH MILL","FISHER","Flynn Road","Forest Beach Rd","GARRETTS ROAD","GATE 2","GORDON","GORDON STREET","GPO Box 4066","Gadsbys Road","Gate 3 Tahmoor Colliery","Gilfillan Rd","Glenbawn Dam Via Scone","Glennies Creek Coal Mine","Glenthompson-Caramut Road","Global Switch","Global Switch Ultimo","Goonyella Road","Grahams Rd (Via Dalby-Kogan Rd)","Grand Junction Road","Grasstree Rd Via Tiera","Grasstree Road","Gurrundah Road","HUME DAM","HUME DAM NSW","HUNTER STREET","Halls Road","Hamilton Road","Hanson Road","Harrisons Rd","Heemskirk Road","Hexham-Woorndoo Road","Homewood Road","Intercast And Forge","Ixom Laverton","JOHN BUTTERS","JONES ROAD","Jennings Road","Jindabyne Dam Spillway,","Jounama Dam Road Via Snowy Mountains Hwy","KEEPIT DAM","KIEWA VALLEY HIGHWAY","Keith Venables Rd","Keith Venables Road","Kevin Livingston Drive","Kiandool Rd","Kirchner Road","Kook Rd","LAKE ECHO","LEMONTHYME","LIAPOOTAH","LIDDELL","LOT 1","LOT 1 MITTONS LANE","LOT 2","LOT 203 REDDALLS ROAD","LOT 6 STOCKWELL ROAD","Lalbert Kerang Road","Lalbert-Kerang Road","Leirda Road South","Lerida Road Nth","Little Glory Road","Lochiel - Snowtown Road","Lot 1","Lot 1 Dp 1191197","Lot 1 Flinders Highway","Lot 1 On Sp305114, 493 Blowers Road","Lot 1 On Sp305925, Pub Lane","Lot 1, Bowser Road","Lot 100","Lot 101,","Lot 12 Chrysler Road","Lot 125, Dalby-Kogan Road","Lot 138 Munro Road","Lot 147 Monarto Road","Lot 16 Adelaide-Mannum Rd Hd Tungkillo","Lot 19, Little Forest Road","Lot 2 Gilbertson Road","Lot 2 Marlborough-Sarina Road","Lot 2 McLaren Street","Lot 2 Old Kidston Road","Lot 2 On RP742329, Bowen Developmental Road","Lot 2 Ps725239","Lot 2, Hunter Road","Lot 2, Rp 742329, Strathmore Road","Lot 20 TP487486M","Lot 27","Lot 3","Lot 3 On Rp 611829","Lot 401 / Dp 1227784, Pat Meredith Drive","Lot 48 BWR138,","Lot 5 Spine Road","Lot 51, Jacksons Road","Lot 558 Corner Locks Road And Bungama Road","Lot 7 & 8, Dp 1245348","Lot 7, Kippen Drive","Lot 91 Maybank Road","Lot27 As Part Of Lot 7 Dp 1037092","Lots 33 -35, Capricon Highway","Lots 4,7,91,92,93 Chandlers Hill Road","Lt 227, F169166 Black Springs Rd","Lts 4,5,6,7,8,9 Hodgson Road","Lucas Height Landfill","MACKAY GAS TURBINE","MACKINTOSH","MACKNADE SUGAR MILL","MAIDENWELL ROAD","MARIAN MILL","MEADOW BANK","MERSEY RD","MILL ROAD","MINTARO","MITTAGANG ROAD","MORWELL","MS 460","MT PIPER POWER STATION","MUNMORAH POWER STATION","Macarthur-Hawkesdale Road","Mcleod Street","Meatworks Road","Midland Highway And Fords Lane","Mill St","Mine Access Rd Via Goonyella Rd","Mitchell Highway","Monaro Highway And Mugga Lane","Mooleric Road","Mort Street","Multiple Site","Multiple Sites","Mulwala Canal","Mutliple Sites","NEMMCO","NEW ENGLAND HIGHWAY","NN","New England Highway","Niagara Road Near Corner Of Bunya Hwy","No. 9 Bolivar Interchange Connector","Northhampton Dale Rd","Nyngan Solar Plant","Oaky Creek Mine Road","Off Eildon Pondage Weir Wall","Off Glenmaggie Lake Weir Wall, Ryans Road","Off Gywdir Highway","Off Lake William Hovell Weir Wall","P.O. BOX 15","P.O. BOX 195","PALOONA","PELICAN POINT ROAD","PLANE CREEK MILL","PLEYSTOWE MILL","PO BOX 107","PO BOX 320 R","PO BOX 392","PO BOX 398","PO BOX 5046","PO BOX 5895","PO BOX 7077 RIVERSIDE CENTRE","PO Box 786","POATINA","POINT HENRY ROAD","POONADA ROAD","PORTLAND POWER SERVICES","PRINCES HIGHWAY","Pacific Hydro P3C Substation","Part 950 Back Trundle Road","Peak Downs Highway","Pigeon Flat Road","Pinnacles Road","Port Latta Substation","Princess Highway","Pt Sec 445 Goyder Hwy","Pyrenees Highway","Que River Mine Site","Queanbeyan Transgrid Substation","RACECOURSE MILL AND REFINERY","REECE","REPULSE","ROAD 55, MOFFATT RESERVE ROCKY CREEK ROAD","ROCKY POINT ROAD","Range Road","Remount Rd","Rocky Point Road","SECTION 244 ","SECTION 244 HUNDRED MAYURRA","SNOWY MTS HIGHWAY","SOMERSET DAM","SPRING MOUNTAIN ROAD","STOCKTON BOREHOLE COLLIERY, RAILWAY STREET","Sarina Maryborough Road","Scenic Drive","Se Water's Pressure Reducing Station WB058","Sec 188 Caltowie Tarcowie Road","Sec 188 Caltowie-Tarcowie Road","Sec 188 Tarcowie Caltowie Road","Sec 248 Pipeline Road","Shultz Rd","Silcocks Hill Road","Single Site","Sixteen Mile Hall Road","Smart Road","Station Road","Stockyard Hill Road","Substation Road","Sydney Airport Domestic","TARRALEA","THE WILLOWS ROAD","TRAMWAY ROAD","TREVALLYN","TRIBUTE","TRUEMAN'S ROAD","TUNGATINAH","Tangmangaroo Road","Tarago Rd","The Crossroads","Torrens Island Nth","Trahairs Road","VALES POINT POWER STATION","Vances Crossing Road","Via Charlton Victoria","Via Grand Truckway","Via Grand Trunkway","Via Windy Hill, Atherton Tablelands","Visy Smithfield","WALLERAWANG POWER STATION","WALLGROVE ROAD","WEST NOWRA LANDFILL, FLATROCK ROAD","WEST ROAD","WESTERN HIGHWAY","WIVENHOE-SOMERSET ROAD","Warrah Rd","Warrakimbo Road","Warrego Highway","Waterloo Road","Weeamera Road","Wheaton Road","Wilkins Highway","Wilton Rd","Wokurna Road","Woolnorth Wind Lot 1","Woorndo-Streathan Road","YORKE PENINSULA","Yallah Bay Rd","Yanga Way","Yo Ho Road"]},"ADDRESS2":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Station Address","examples":["(Inside The Goulburn Valley Water Waste Treatment Facility)","(lot 14 SP125736 And Lot 100 Of SP260668)","124 Coulsons Road","1530 Wuthung Road","240 Monash Way","7W Belgrave Rd And Hallam Rd","8827 Monaro Highway","ALBERT STREET","Awaba","Back Eildon Road","Barrier Highway","Bass Highway","C/0 POST OFFICE","C/O WALLERAWANG POST OFFICE","CHERRY LANE","COAL MINES ROAD","COMMERCIAL ROAD","Central Highlands","Cnr Deals And Ryans Rd","Corner Of Berrigan Road And Melrose Lane","Corner Of Railway Street And Mountain Road","Crudine Ridge Wind Farm","Dp 12437","Dp 600393","GREENVALE ST","Grahams Rd","HUNDRED MAYURRA ","Invicta Mill Estate","KIEWA VALLEY HIGHWAY","Kosciusko Rd,","LOCKED MAIL BAG NO. 1","Lalbert-Kerang Road","Little Forest Road","Lot 34","Lots 303, 304, 330 And 389 Of DP753734","MT STUART","MT. BEAUTY","MT. BEAUTY  3699","Mair Street","McNulty Road","Mt Wallace Ballark Road (South)","Multiple Sites","Mutliple Sites","North Goonyella Rd","Off Booborwie Rd","Off Range Road","Onslow Ave","PORT ADELAIDE","PORT AUGUSTA","PRIVATE BAG NO. 1","QUARRY ROAD","Quarry Road","Que River Road","ROCKHAMPTON MAIL CENTRE","Racecourse","Refinery Road","Remembrance Drive","Single Site","Smithfield","Stage 2 Spine Rd","Stuart","Sydney West Substation","Upper Kind River Road","Wallgrove Road","YALLOURN"]},"ADDRESS3":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Station Address","examples":["Barrier Highway","Braemar","Cullens Road","MT. BEAUTY  3699","Murchison Highway","NEAR MILLICENT","Nagari Road","POST OFFICE"]},"ADDRESS4":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Station Address","examples":["Adelaide, SA, 5000","Aldoga, QLD, 4695","Bael Bael, VIC, 3579","Balranald, NSW, 2715","Birkenhead, SA, 5015","Blyth, SA, 5462","Brendale, QLD, 4500","Brisbane, QLD, 4000","Brisbane, QLD, 4500","Brisbane, QLD1, 4000","Bullyard, QLD, 4671","Canberra, ACT, 2600","Carwarp, VIC, 3494","Cement Mills, QLD, 4358","Clarke Creek, QLD, 4705","Clements Gap, SA, 5523","Colongra, NSW, 2262","Cranbourne West, VIC, 3977","Culcairn, NSW, 2660","Einasleigh, QLD, 4871","Eraring, NSW, 2264","Girgarre, VIC, 3624","Goondiwindi, QLD, 4390","Goorambat, VIC, 3725","Grass Tree Mine","Greenbank, QLD, 4124","Hastings, VIC, 3915","Hawkesdale, VIC, 3287","Hazelwood North, VIC, 3840","Hopeland, QLD, 4413","Jandowae, QLD, 4410","Jindera, NSW, 2642","Kerang, VIC, 3579","Kingaroy, QLD, 4610","Lancaster, VIC, 3620","Lithgow, NSW, 2790","Lower Wonga, QLD, 4570","Loxford, NSW, 2326","Mannum, SA, 5238","Marlborough, QLD, 4705","Melbourne, VIC, 3000","Mortlake, VIC, 3272","Morwell, VIC, 3840","Mulwala, NSW, 2647","Munna Creek, QLD, 4570","Muswellbrook, NSW, 2333","Napperby, SA, 5540","North Wangaratta, VIC, 3678","Nyngan, NSW, 2825","Orford, VIC, 3284","PO BOX 444","Parkes, NSW, 2870","Pine Lodge, VIC, 3631","Plumpton, VIC, 3335","Rokewood, VIC, 3330","Smithfield, NSW, 2164","Stanwell, QLD, 4702","Stubbo, NSW, 2852","Swanbank, QLD, 4306","Sydney, NSW, 2000","Sydney, NSW, 2020","Sydney, NSW, 2161","Tailem Bend, SA, 5260","Tarong, QLD, 4615","Templers, SA, 5371","Tepko, SA, 5254","Terang, VIC, 3264","Tichular, NSW, 2850","Tully, QLD, 4854","Tyabb, VIC, 3913","Ultimo, NSW, 2007","Upper Haughton, QLD, 4809","Uralla, NSW, 2358","Walla Walla, NSW, 2660","Wellington, NSW, 2820","Werneth, VIC, 3352","Williamsdale, ACT, 2900","Winton, VIC, 3673","Wunghnu, VIC, 3635","Wuuluman, NSW, 2820"]},"CITY":{"sql_type":"VARCHAR2(40)","pl_type":"pl.Categorical","mandatory":false,"comment":"City","examples":["ADELAIDE","ANGASTON","ANGELSEA","ARRIGA","ASHFORD","Abermain","Adelaide","Aldoga","Appin","Ararat","Argyle","Arriga","BAIRNSDALE","BELL BAY","BEMBOKA","BILOELA","BRISBANE","BROOKLYN","BUANGOR","BUDGEWOI","BURRINJUCK","Bael Bael","Baking Board","Ballan","Ballarat","Balranald","Banana","Bankstown","Bannerton","Bannister","Barcaldine","Barooga","Beatty","Bell Bay","Birkenhead","Blyth","Bodangara","Bodangora","Bolivar","Bomaderry","Bomen","Bordertown","Bouldercombe","Boyneside","Brendale","Brigalow","Brisbane","Broadmeadows","Broadwater","Broken Hill","Bullyard","Bungendore","Burra","CALLIDE","CAMELLIA","CAPE JERVIS","COOMA","Caltowie","Caltowie North","Canberra","Carwarp","Cement Mills","Chepstowe","Cheshunt","Chinchilla","Chirnside Park","Christies Beach","Clare","Clarke Creek","Clayton South","Clements Gap","Clermont","Codrington","Coleambally","Collinsville","Colongra","Condong","Cooriemungle","Corio","Corowa","Cowes","Cranbourne West","Crookwell","Crossroads","Crowlands","Culcairn","Cullerin","DAANDINE","DRY CREEK","Daandine ","Darlington Point","Dartmonth ","Douglas Park","Doyalson","Drillham","Drumanure","Dubbo","Dummy","EASTERN CREEK","EILDON","ERARING","Eastern Creek","Eildon","Einasleigh","Elaine","Elizabeth","Emerald","Emeroo","Eraring","Errowanbang","FARLEIGH","FERNVALE","FITZGIBBON","Fernvale","Finley","GLADSTONE","GORDONVALE","GYMPIE","Gawler Belt","George Town","Geranium Plains","German Creek ","Gillman","Girgarre","Giru","Gladstone","Glenmaggie","Glenrowan","Glenrowan West","Glenthompson","Goondiwindi","Goorambat","Granville Harbour","Greenbank","Gulgong","Gunnedah","Gurrandah","HALLETT","HOBART","Hallam","Hallett","Hampton Park","Happy Valley","Hastings","Hawkesdale","Hazelwood","Hazelwood North","Heritage Park","Highbury","Hillston","Hobart","Hookswood","Hopeland","Horfield","Hughenden","Hume Weir","IPSWICH","Ingham","Inverell","Isis Central","Isis River","JEERALANG","Jamestown","Jandowae","Jemalong","Jerrabombera","Jerrabomberra","Jindabyne","Jindera","Joel Joel","KANGAROO VALLEY","KEEPIT DAM","KOOLKHAN","Kangiara","Kemps Creek","Kerang","Kiata","Kidston","Kincumber","Kingaroy","Kogan","Kogarah","LAVERTON NORTH","LIDDELL","LONGFORD","LONSDALE","Lancaster","Laverton","Leonards Hill","Leumeah","Liparoo","Lithgow","Longreach","Lonsdale","Lower Wonga","Loxford","MACKAY","MACKNADE","MANNERING PARK","MARIAN","MELBOURNE","MENAI","MILLMERRAN","MINTARO","MOE","MORWELL","MOUNT MILLAR","Macarthur","Mackay","Manildra","Mannum","Mareeba","Marinna","Marlborough","Maroona","Marsden Park ","Matheson","Melbourne","Menai","Merriton","Middlemount","Mildura","Miles","Molong","Montefiores","Moorabool, Greater Geelong","Moranbah","Moree","Morgan","Mortlake","Morwell","Mount Wallace","Mowbray","Mt Bryan","Mt Mercer","Multiple Sites","Mulwala","Munna Creek","Murra Warra","Musselroe Bay","Muswellbrook","NANANGO","NEAR MILLICENT/TANTOOLA","NEWPORT","NSW","Napperby","Nareeb","Narrabri","Narre Warren North","Narromine","Nevertire","Nhill","North Wangaratta","Nyngan","OAKEY","OSBORNE","OUTER HARBOUR","Oakey","Ombersley","Orford","Outer Harbour","Ouyen","PLEYSTOWE","POINT HENRY","PORT ADELAIDE","PORT AUGUSTA","PORT LINCOLN","PORT MACQUARIE","PORTLAND","Palmer","Parkes","Pelaw Main","Penola","Pine Lodge","Pinnacles","Plumpton","Port Augusta","Port Latta","Port Melbourne","Portland","Pyramul","Queensland","REDLYNCH","ROCHEDALE","ROCKHAMPTON","RYDALMERE","RYE","Ravenhall","Robertstown","Rocky Gully","Rokewood","Roma","Ross","Rye Park","SARINA","SLEAFORD","SNUGGERY","SOMERTON","STAPYLTON","SUNSHINE","SYDNEY","Sandigo","Scone","Seaford Heights","Shepparton","Silverton","Singleton","Sladevale","Smithfield","Snowtown","South Brisbane","Spring Farm","Springfield","Springlands","Springvale","St Agnes","St Leonards","Stansbury","Stanwell","Stapylton","Stockyard Hill","Stubbo","Susan River","Swanbank","Sydney","TANTANOOLA","TERALBA","TOORA","TOWNSVILLE","TRARALGON","TRARALGON SOUTH","TULLY","Tahmoor","Tailem Bend","Talbingo","Tantanoola","Tarago","Taralga","Tarong","Tarwin Lower","Tasmania","Tatura","Temora","Templers","Tepko","Terang","Tichular","Tieri","Timboon West","Toowoomba","Torrens Island","Townsville","Traralgon","Trawool","Tuggeranong","Tully","Tumoulin","Tyabb","Ultimo","Unanderra","Upper Haughton","Uralla","Uranquinty","VIA RAVENSHOE","VIC","Valdora","Via Dalby","WALLERAWANG","WARKWORTH VIA SINGLETON","WARRAGAMBA DAM","WERRIBEE","WEST DAPTO","WEST NOWRA","WODONGA","WOLLNORTH","WONTHAGGI","WOONGOOLBA","Waddamana","Wagga Wagga","Walla Walla","Wallinduc","Wandella","Waratah","Warrenheip","Waterloo","Waubra","Wellington","Werneth","Williamsdale","Willoughby","Willowbank","Wilmot","Wingfield","Winninowie","Winton","Wokurna","Woleebee","Wollert","Woodhouselee","Woodstock","Woorndo","Woorndoo","Woy Woy","Wunghnu","Wuuluman","Wyalong","Wyangala Village","Wyangala Villiage","YAMBUK","YORKETOWN","Yallah","Yarranlea","Yarrawonga","Yatpool","Yawong Hills","Yendon","Yoogali"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2003/11/25 15:34:57"],"parse_csv_as_string":true,"is_s_datetime":true},"POSTCODE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Post Code","examples":["220","ADELAIDE","54891","BRISBANE","COOMA","PORTLAND"],"is_categorical":true},"STATE":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"State of Australia","examples":["ACT","NSW","QLD","QLD1","Queensland","SA","TAS","VIC"],"is_categorical":true},"STATIONNAME":{"sql_type":"VARCHAR2(80)","pl_type":"pl.Categorical","mandatory":false,"comment":"Full name of station","examples":["AGL KEMPS CREEK","ANGASTON POWER STATION","ANGELSEA POWER STATION","AS ACLESGA V VL1","AS AES NSW","AS BOHLE BESS Q VL1","AS DIAMD01 V SL1","AS ENGIE N VL1","AS ENGIE V VL1","AS FIRMGRID TAS1","AS PAPOWERMG S 1","AS POWERSYNC V VL 1","AS Sonnen SA","AS TEP ENLOC N VL2","AS TEP ENLOC V VL2","ASGENE01","ASRMGE01","ASRMGE02","ASRMGE03","ASRMGE04","ASRMGE05","ActewAGL VPP","Adelaide Desalination Plant","Aldoga Solar Farm","Amcor Glass, Gawler Plant","Appin Power Plant","Ararat Wind Farm","Avonlie Solar Farm","Awaba Power Station","BELL BAY","BHAS ZINC PLANT SA","BLOWERING","BRAEMAR 2 POWER STATION","Bairnsdale Power Station","Baking Board Solar Farm","Bald Hills Wind Farm","Ballarat Base Hospital Plant","Ballarat Battery Energy Storage System","Bango 973 Wind Farm","Bango 999 Wind Farm","Banimboola Power Station","Bankstown Sports Club Plant Units","Bannerton Solar Park","Barcaldine Power Station","Barcaldine Solar Farm","Barker Inlet Power Station","Barron Gorge Power Station","Basslink HVDC Link","Bastyan Power Station","Bayswater Power Station","Bell Bay Power Station","Bell Bay Three Power Station","Berrybank 1 Wind Farm","Berrybank 2 Wind Farm","Berwick Power Plant","Beryl Solar Farm","Blowering Power Station","Blue Grass Solar Farm","Blue Lake Milling Power Plant","Blyth Battery Energy Storage System","Boco Rock Wind Farm","Bodangora Wind Farm","Bogong / Mackay Power Station","Bolivar Power Station","Bolivar Waste Water Treatment Plant","Bomen Solar Farm","Boral Aggregated Load NSW1","Bouldercombe Battery Project","Braemar Power Station","Brendale BESS","Broadmeadows Landfill Gas Power Station","Broadsound Energy Park","Broadwater Power Station","Broken Hill Battery Energy Storage System","Broken Hill Gas Turbines","Broken Hill Solar Plant","Brooklyn LFG U1-3","Brown Mountain Hydro Power Station","Browns Plains Landfill Gas PS","Bulgana Green Power Hub","Bundaberg Solar Farm","Bungala One Solar Farm","Bungala Two Solar Farm","Bungama Battery Energy Storage System","Burrendong Hydro Power Station","Burrinjuck Hydro Power Station","Butlers Gorge Power Station","CALLIDE C NETT OFF","CANUNDA WIND FARM ","CATHEDRAL ROCKS","CLOVER POWER STATION","Callide Power Station","Capital Battery","Capital East Solar Farm","Capital Wind Farm","Carwarp Solar Farm","Catagunya / Liapootah / Wayatinah Power Station","Cattle Hill Wind Farm","Cethana Power Station","Challicum Hills Wind Farm","Chepstowe Wind Farm","Cherry Tree Wind Farm","Childers Solar Farm","Chinchilla BESS","Christies Beach WWTP","Clare Solar Farm","Clarke Creek Wind Farm","Clayton Landfill Gas Power Station","Clements Gap BESS","Clements Gap Wind Farm","Clermont Solar Farm","Cluny Power Station","Codrington Wind Farm","Cohuna Solar Farm","Coleambally Solar Farm","Collector Wind Farm","Collinsville Power Station","Collinsville Solar PV Power Station","Colongra Power Station","Columboola Solar Farm","Condamine Power Station A","Condong Power Station","Coonoer Bridge Wind Farm","Coopers Gap Wind Farm","Copeton Hydro Power Station","Corio Landfill Gas Power Station","Corowa Solar Farm","Crookwell 2 Wind Farm","Crookwell 3 Wind Farm","Crowlands Wind Farm","Crudine Ridge Wind Farm","Culcairn Solar Farm","Cullerin Range Wind Farm","DALBYSGA","DARTMOUTH POWER STATION","DLINK INTERCONNECTOR","DR ACACIA N SL1","DR ACACIA V 1","DR AES N VL1","DR BORAL V SL1","DR ENELX N1","DR ENELX N16","DR ENELX N3","DR ENELX N31","DR ENELX N32","DR ENELX N34","DR ENELX N36","DR ENELX N37","DR ENELX N40","DR ENELX N42","DR ENELX N44","DR ENELX N49","DR ENELX N54","DR ENELX N55","DR ENELX N83","DR ENELX Q50","DR ENELX Q54","DR ENELX S2","DR ENELX V1","DR ENELX V12","DR ENELX V17","DR ENELX V2","DR ENELX V24","DR ENELX V240","DR ENELX V88","DR FIRM INFRA T 1","DR FIRM INTRA T 2","DR HYDROTASVPP N 1","DR OZVPPQ S 1","DR POWERSYNC Q 1","DR POWERSYNC V 1","DR VIOTAS N SL1","DR VIOTAS Q SL1","DR VIOTAS S SL1","DR VIOTAS T SL1","DR VIOTAS V SL1","DR VIOTASWDR N 1","DR VIOTASWDR Q 1","DR VIOTASWDR S 1","DRAESN3","DRAESS1","DREXMN01","DRGBND01","DRGBND02","DRGBND04","DRGND03","DRHTVP03","DROZVP01","DROZVP02","DRSHVN01","DRSHVN02","DRSHVQ01","DRSHVS01","DRXNSS01","Daandine Power Station","Dalrymple North BESS","Darling Downs Power Station","Darling Downs Solar Farm","Darlington Point Energy Storage System","Darlington Point Solar Farm","Daydream Solar Farm","Devils Gate Power Station","Diapur Wind Farm","DiscoverEnergy VPPSA","Dry Creek Gas Turbine Station","Dulacca Wind Farm","Dundonnell Wind Farm","EILDON POWER STATION","ENOC MASP QLD","ENOC MASP SA","ENOC MSAP NSW","ENOC MSAP VIC","ERARING POWER STATION","ERGON FREQUENCY CONTROL A.S.","EarthPower Biomass Plant","Eastern Creek 2 Gas Utilisation Facility","Eastern Creek LFG PS Units 1-4","Edenvale Solar Park","Eildon Power Station","Elaine Wind Farm","Emerald Solar Park","Energy Brix Complex Power Station","Energy Locals SA VPP","Eraring Battery Energy Storage System","Eraring Battery Energy Storage System 2","Eraring Power Station","FARLEIGH MILL","Ferguson North Wind Farm","Ferguson South Wind Farm","Finely Solar Farm","Firmus St Leonard DC","Fisher Power Station","Flyers Creek Wind Farm","GEORGE TOWN DIESEL","GLADSTONE POWER STATION","GLENROWAN SOLAR FARM","Gangarri Solar Farm","Gannawarra Energy Storage System","Gannawarra Solar Farm","German Creek Power Station","Girgarre Solar Farm","Glenbawn Hydro Power Station","Glenellen Solar Farm","Glenmaggie Hydro Power Station","Glennies Creek Power Station","Glenrowan West Solar Farm","Golden Plains Wind Farm East","Golden Plains Wind Farm West","Goonumbla Solar Farm","Goorambat East Solar Farm","Gordon Power Station","Goyder South Wind Farm 1A","Goyder South Wind Farm 1B","Grange Avenue Landfill Gas Power Station","Granville Harbour Wind Farm","Greenbank BESS","Griffith Solar Farm","Grosvenor 1 Waste Coal Mine Gas Power Station","Grosvenor 2","Gullen Range Wind Farm","Gunnedah Solar Farm","Gunning Wind Farm","Gunsynd Solar Farm","Guthega Power Station","HALLAM ROAD RENEWABLE ENERGY FACILITY","HRL TRAMWAY ROAD","Hallett 1 Wind Farm","Hallett 2 Wind Farm","Hallett Power Station","Hamilton Solar Farm","Happy Valley WTP","Hastings Generation Site","Haughton Solar Farm Stage 1, Units 1-81","Haughton Synchronous Condenser","Hawkesdale Wind Farm","Hayman Solar Farm","Hazelwood Battery Energy Storage System","Hazelwood Power Station","Hepburn Community Wind Farm","Highbury Landfill Gas Power Station","Hillston Sun Farm","Hornsdale Power Reserve","Hornsdale Wind Farm","Hornsdale Wind Farm 2","Hornsdale Wind Farm 3","Hughenden Solar Farm","Hume (NSW) Hydro Power Station","Hume (Vic) Hydro Power Station","Hunter Economic Zone","Hunter Economic Zone Power Station","Hunter Power Station","Hunter Valley Gas Turbine","HydroTas MASP TAS","ISIS Central Sugar Mill Co-generation Plant","Invicta Sugar Mill","Jacks Gully Landfill Gas Power Station","Jeeralang \"A\" Power Station","Jeeralang \"B\" Power Station","Jemalong Solar Project","Jindabyne Pump At Guthega","Jindabyne Small Hydro Power Station","John Butters Power Station","Jounama Small Hydro Power Station","Junee Solar Farm","KAREEYA POWER STATION","KOOLKHAN GAS TURBINE","KRC Cogeneration Plant Power Station","Kaban Wind Farm","Karadoc Solar Farm","Keepit Hydro Power Station","Kennedy Energy Park","Kerang Solar Plant","Kiamal Solar Farm","Kiata Wind Farm","Kidston Hydro Project","Kidston Solar Project","Kincumber Landfill Site","Kingaroy Solar Farm","Kogan Creek Power Station","Koorangie Energy Storage System","LONGFORD PLANT","LOY YANG A POWER STATION","LOY YANG B POWER STATION","Ladbroke Grove Power Station","Lake Bonney BESS1","Lake Bonney Stage 2 Windfarm","Lake Bonney Stage 3 Wind Farm","Lake Bonney Wind Farm Stage 1","Lake Echo Power Station","Lancaster Solar Farm","Latrobe Valley BESS","Laverton North Power Station","Lemonthyme / Wilmot Power Station","Liddell Battery Energy Storage System","Liddell Power Station","Lilyvale Solar Farm","Limondale Battery","Limondale Solar Farm 1","Limondale Solar Farm 2","Lincoln Gap Wind Farm","Longreach Solar Farm","Lonsdale Power Station","Lucas Heights 2 Power Station","Lucas Heights II Power Plant","MACKAY GAS TURBINE","MACKNADE SUGAR MILL","MARIAN MILL","MOREE SOLAR FARM","MT PIPER POWER STATION","MULGRAVE CENTRAL MILL","MUNMORAH POWER STATION","MURLINK INTCONNECTOR","MURRAY1","MURRAY2","MacIntyre Wind Farm","Macarthur Wind Farm","Mackintosh Power Station","Manildra Solar Farm","Mannum 2 Solar Farm","Mannum Battery Energy Storage System","Mannum-Adelaide Pipeline Pumping Station No 2","Mannum-Adelaide Pipeline Pumping Station No 3","Maroona Wind Farm","Maryrorough Solar Farm","Meadowbank Power Station","Melbourne Regional Landfill","Melbourne Renewable Energy Hub Connection A1","Melbourne Renewable Energy Hub Connection A2","Melbourne Renewable Energy Hub Connection A3","Metz Solar Farm","Middlemount Solar Farm","Midlands Power Station","Millmerran Power Plant","Mintaro Gas Turbine Station","Mokoan Solar Farm","Molong Solar Farm","Moorabool Wind Farm","Moranbah Generation Project","Moranbah North Waste Coal Mine Gas Power Station","Morgan-Whyalla Pipeline Pumping Station No 1","Morgan-Whyalla Pipeline Pumping Station No 2","Morgan-Whyalla Pipeline Pumping Station No 3","Morgan-Whyalla Pipeline Pumping Station No 4","Mornington BESS","Mornington Waste Disposal Facility","Mortlake Battery Energy Storage System","Mortlake Power Station","Mortlake South Wind Farm","Mortons Lane Wind Farm","Mount Emerald Wind Farm","Moura Solar Farm","Mt Gellibrand Wind Farm","Mt Mercer Wind Farm","Mt Millar Wind Farm","Mt Stuart Power Station","Mugga Lane Landfill Gas To Energy Facility","Mugga Lane Solar Park","Mulwala Solar Farm","Munna Creek Solar Farm","Murra Warra Wind Farm","Murra Warra Wind Farm Stage 2","Murray Bridge-Onkaparinga Pipeline Pumping Station No 2","Murray Power Station","Musselroe Wind Farm","NEVERTIRE SOLAR FARM","NEWPORT POWER STATION","NORTHERN GAS TURBINE","NORTHERN POWER STATION","NSW1 Dummy Generator","Narromine Solar Farm","New England BESS","New England Solar Farm","Nine Network Willoughby Plant","North Brown Hill Wind Farm","Numurkah Solar Farm","Nyngan Solar Plant","OAKEY POWER STATION","ORANA BESS","OSBORNE POWER STATION","Oakey 1 Solar Farm","Oakey 2 Solar Farm","Oaklands Hill Wind Farm","Oaky Creek 2","Oaky Creek Power Station","PB Community SGA","PLANE CREEK MILL","PLEYSTOWE MILL","POINT HENRY SMELTER","PORTLAND","Paloona Power Station","Parkes Solar Farm","Pedler Creek Landfill Gas Power Station Units 1-3","Pelican Point Power Station","Phillip Island BESS","Pindari Hydro Power Station","Pine Lodge BESS","Pioneer Sugar Mill","Playford B Power Station","Poatina Power Station","Port Augusta Renewable Energy Park","Port Latta Diesel Generator","Port Lincoln Gas Turbine","Portland Wind Farm","Pt Stanvac Power Station","QLD1 Dummy Generator","Quarantine Power Station","Que River Diesel","Queanbeyan BESS","Quorn Park Solar Hybrid","RACECOURSE MILL","RESERVE TRADER NSW1","RESERVE TRADER QLD1","RESERVE TRADER SA1","RESERVE TRADER TAS1","RESERVE TRADER VIC1","Racecourse Mill Power Station","Rangebank BESS","Redbank Power Station","Reece Power Station","Remount Power Station","Repulse Power Station","Riverina BESS 1","Riverina Energy Storage System 2","Rochedale Renewable Energy Facility","Rocky Point Cogeneration Plant","Roghan Road LFG Power Plant","Roma Gas Turbine Station","Ross River Solar Farm","Rowallan Power Station","Royalla Solar Farm","Rubicon Mountain Streams Station","Rugby Run Solar Farm","Ryan Corner Wind Farm","Rye Park Renewable Energy","SA1 Dummy Generator","SCSF","SMITHFIELD ENERGY FACILITY","SNOWY","SNUGGERY POWER STATION","SOMERSET DAM","SOUTH JOHNSTONE","STANWELL POWER STATION","STAPYLTON","SUNSHINE ENERGY","Salt Creek Wind Farm","Sapphire Wind Farm","Sebastopol Solar Farm","Shell Energy Retail DR VIC 1","Shepparton Wastewater Treatment Facility","Shoalhaven Power Station (Bendeela And Kangaroo Valley Power Station And Pumps)","Shoalhaven Starches Cogeneration Plant","Silverton Wind Farm","Smithfield Battery Energy Storage System","Snapper Point Power Station","Snowtown South Wind Farm","Snowtown Wind Farm Stage 2 North","Snowtown Wind Farm Units 1 And 47","Somerton Power Station","South East Water - Halllam Hydro Plant","South Keswick Solar Farm","Southbank Institute Of Technology Unit 1 Plant","Springvale Landfill Gas Power Station","St George Leagues Plant","Stanwell Battery Energy Storage System","Stapylton Renewable Energy Facility","Starfish Hill Wind Farm","Station ID - Dummy (NSCAS)","Stockyard Hill Wind Farm","Stubbo Solar Farm 1","Stubbo Solar Farm 2","Summerfield BESS1","Summerfield BESS2","Sun Metals Solar Farm","Suncoast Gold Macadamias","Sunraysia Solar Farm","Suntop Solar Farm","Supernode BESS","Susan River Solar Farm","Swanbank B Power Station & Swanbank E Gas Turbine","Swanbank BESS","Symex Power Plant","TABLELAND MILL","TARONG POWER STATION","TAS1 Dummy Generator","TERALBA POWER STATION","TERANG BESS","TOMAGO SMELTER","TOORA WIND FARM","TORRENS ISLAND POWER STATION","TUMUT1","TUMUT2","TUMUT3","Tableland Mill Unit 2","Tahmoor Waste Coal Mine Gas Power Station","Tailem Bend 2 Hybrid Renewable Power Station","Tailem Bend 3 BESS","Tailem Bend Solar Project 1","Tallawarra Power Station","Tamar Valley Combined Cycle Power Station","Taralga Wind Farm","Tarong BESS","Tarong North Power Station","Tarraleah Power Station","Tataria Bordertown Plant","Tatura Biomass Generator","Tea Tree Gully Landfill Gas Power Station","Templers Battery Energy Storage System","Temporary Generation North","Temporary Generation South","Terminal Storage Mini Hydro Power Station","The Bluff Wind Farm","The Drop Power Station","Timboon West Wind Farm","Torrens Island BESS","Tower Power Plant","Townsville Gas Turbine","Traralgon Network Support Station","Trevallyn Power Station","Tribute Power Station","Tully Sugar Mill","Tumut 3 Power Station","Tumut 3 Pumps","Tumut Power Station","Tungatinah Power Station","UWS CO-GEN UNIT","Ulinda Park BESS","Uranquinty Power Station","Uungula Wind Farm","VALLEY POWER","VIC1 Dummy Generator","VICTORIAN SMELTER ANCILLARY SERVICES","VPP AGLE SA 1","VPP Energy Locals NSW 2","VPP Energy Locals SA 1","VPP Energy Locals VIC 2","VPP HT QLD 1","VPP ShinHub DRSHVS02","VPP ShinHub SA 1","VPP Simply SA 1","VPP Sonnen NSW 1","Vales Point \"B\" Power Station","Valley Power Peaking Facility","Veolia Ti Tree Bio Reactor","Victoria Mill","Victorian Big Battery","WARRAGAMBA POWER STATION","WARWICK SOLAR FARM 1","WARWICK SOLAR FARM 2","WAUBRA WIND FARM","WEST KIEWA POWER STATION","WHYTES GULLY","WIVENHOE POWER STATION","WIVENHOE SMALL HYDRO","Wagga North Solar Farm","Walla Walla Solar Farm 1","Walla Walla Solar Farm 2","Wallerawang Power Station","Wallgrove BESS 1","Wambo Wind Farm 1","Wambo Wind Farm 2","Wandoan BESS","Wandoan Solar Farm","Wangaratta Solar Farm","Waratah Super Battery","Waterloo Wind Farm","Wattle Point Wind Farm","Wellington North Solar Farm","Wellington Solar Farm","Wemen Solar Farm","West Illawarra Leagues Club Plant","West Nowra Landfill Gas Power Generation Facility","West Wyalong Solar Farm","Western Downs Battery Energy Storage System (BESS)","Western Downs GPH","Western Suburbs League Club (Campbelltown) Plant","White Rock Solar Farm","White Rock Wind Farm","Whitsunday Solar Farm","Whitwood Road Renewable Energy Facility","Wilga Park B","Wilga Park Power Station","William Hovell Power Station","Williamsdale BESS","Willogoleche Wind Farm","Windy Hill Wind Farm","Wingfield 1 Landfill Gas Power Station","Wingfield 2 Landfill Gas Power Station","Winton Solar Farm","Wollar Solar Farm","Wollert Renewable Energy Facility","Wonthaggi Wind Farm","Woodlawn Bioreactor Energy Generation Station","Woodlawn Wind Farm","Woolnorth Studland Bay / Bluff Point Wind Farm","Woolooga BESS","Woolooga Solar Farm","Wooreen Battery Energy Storage System","Woy Woy Landfill Site","Wunghnu Solar Farm","Wyalong Solar Farm","Wyangala A Power Station","Wyangala B Power Station","Wyndham Waste Disposal Facility","YALLOURN 'W' POWER STATION","YAMBUK WIND FARM","Yaloak South Wind Farm","Yarranlea Solar Farm","Yarrawonga Hydro Power Station","Yarwun Power Station","Yatpool Solar Farm","Yawong Wind Farm","Yendon Wind Farm"],"is_categorical":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Not used. Do not use as the Connection Point Identifier for station load","unused":true,"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STATION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":24113,"decompressed_size_all_time":22875730},"visibility":"Public","trigger":"When there is a station configuration change or new unit registration"},"STATIONOPERATINGSTATUS":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"STATIONOPERATINGSTATUS","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#257"],"comment":"STATIONOPERATINGSTATUS sets out the operating status of each station.","description":"STATIONOWNER is public data, and is available to all participants.\n\nSource\n\nSTATIONOWNER is updated whenever there is a change in the station owner\nor new units are registered.","primary_keys":["EFFECTIVEDATE","STATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique station identifier","examples":["AGLHAL","AGLNOW1","AGLSOM","AMCORGR","ANGASTON","APPIN","APS","AWABAREF","B2PS","BANKSPT","BAPS","BARCALDN","BARRON","BASSLINK","BASTYAN","BAYSW","BBASEHOS","BBP31","BDONGHYD","BELLBAY","BERWICK","BHASZINC","BHILLGT","BLOWER","BLUFF","BLULAKE","BPLANDF","BRAEMARA","BROADMDW","BROOKLYN","BROWNMT","BURRIN","BUTLERSG","BWTR1","CALLIDE","CALLIDEC","CALLIDEC1","CANUNDA1","CAPTL_WF","CATHROCK","CETHANA","CHALLWF","CLAYTON","CLEMGPWF","CLOVER","CLUNY","CODRGTON","COLNSV","COLONGRA","CONDONG1","COPTNHYD","CPSA","CULLERIN","DAANDINE","DARTM","DDPS1","DEIBDL","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIRECTLINK","DRYCGT","EASTCRK","EASTCRK2","EDLRGNRD","EILDON","ENERGYB","ERARING","ERGT01","ERG_AS","FARLEIGH","FISHER","G/STONE","GERMCRK","GLBWNHYD","GLENNCRK","GORDON","GRANGEAV","GUNNING","GUTHEGA","HALAMRD","HALLWF","HALLWF2","HAZEL","HEPWIND","HEZ","HLMSEW01","HUMENSW","HUMEV","HUNTVGT","ICSM","INVICTA","JACKSGUL","JBUTTERS","JEERA","JEERB","JINDABYNE","JNDSHPS","JOUNAMA","KAREEYA","KEEPIT","KOGANCK","KOOLKHAN","KRCCOGEN","LADBROKE","LEM_WIL","LIDDELL","LI_WY_CA","LKBONNY1","LKBONNY3","LKBONNY_2","LK_ECHO","LNGS","LONGFORD","LONSDALE","LOYYANGA","LOYYB","LUCAS2S2","LUCASHGT","LYGS","MACARTH","MACKAY","MACKNADE","MACKNTSH","MARIAN","MBAHNTH","MCKAY","MEADOWBK","MILLMERN","MINTARO","MLWF","MM","MORANBAH","MORNW","MORTLK","MP","MSTUART","MTMILLAR","MULGRAVE","MURLINKP","MURRAY","MURRAY1","MURRAY2","MUSSELRO","NBHWF","NEWPORT","NINEWIL","NORTHGT","NORTHP","NPPPPS","OAKEY","OAKLAND","OCPS","OSBORNE","PALOONA","PINDARI","PIONEER","PLANECRK","PLAYF","PLEYSTOW","PMATTAEP","PORTLAND","PORTLCN","PORTWF","PTH","PTINA110","PTINA220","QUARANTN","RACOMIL","RCOURSE","REDBANK1","REECE","REMOUNT","REPULSE","ROCHEDAL","ROMA","ROWALLAN","RPCG","RT_NSW1","RT_QLD1","RT_SA1","RT_TAS1","RT_VIC1","RUBICON","SHEP1","SHOALHAV","SITHE","SNOWTOWN","SNOWY","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYP","SNUG","SNWYGJP2","SOMERSET","STANVAC","STANWELL","STARFHILL","STGEORGE","STHBKTEC","STHJST","STPN1","SUNCOAST","SUNSHINE","SWANBANK","SYMEX","TALLAWAR","TARONG","TARONGN","TARRALEA","TATIARA","TATURA","TBLAND","TERALBA","TERMSTOR","TITREE","TOMAGO","TOORAWF","TORRIS","TOWER","TREVALLN","TRIBUTE","TUMUT1","TUMUT2","TUMUT3","TUNGATIN","TVCCPS","URANQ","UWS","VICMILL","VICSMLT","VP","VPGS","WATERLWF","WAUBRAWF","WCLASS","WDLNGN","WESTCBT","WESTILLA","WG","WGULLY","WHIT1","WILGAPK","WINDHILL","WIVENHOE","WIVENSH","WKIEWA","WONWP","WOODLWN","WOOLNTH1","WPWF","WW","WYANGALA","WYANGALB","WYNDW","YABULU","YALLOURN","YAMBUK","YARWUN","YWNGAHYD"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record within the effective date","examples":["1","51"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["CASSA","DAVIDGA","JBEALE","JEFFP","LUKEB","MARKS","PETAE","REGCHECK","REGISTRATION"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["2000/10/17 10:16:05"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2006/02/01 11:12:44"],"parse_csv_as_string":true,"is_s_datetime":true},"STATUS":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"COMMISSIONED\", \"DECOMMISSIONED\"])","mandatory":false,"comment":"The operating status of this station, valid values are COMMISSIONED and DECOMMISSIONED","examples":null,"enums":["COMMISSIONED","DECOMMISSIONED"]}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STATIONOPERATINGSTATUS%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":18670,"decompressed_size_all_time":17920100},"visibility":"Public","trigger":"When there is a station owner change or new unit registration"},"STATIONOWNER":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"STATIONOWNER","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#266"],"comment":"STATIONOWNER sets out the owner details of each station.","description":"STATIONOWNER is public data, and is available to all participants.\n\nSource\n\nSTATIONOWNER is updated whenever there is a change in the station owner\nor new units are registered.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","STATIONID","VERSIONNO"],"indexes":[["LASTCHANGED"],["STATIONID","EFFECTIVEDATE","VERSIONNO"],["PARTICIPANTID"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","examples":["AGLE","BASSLINK","BBPOWER","BBTHREE","BORAL","CAPTPL","CATHROCK","CHALLHWF","CNRGY","CNUNDAWF","COALCO","CSENERGY","CSR","CUMMINS","DEIBDL","DELTA","DIRLINKP","ECOGEN","EDISON","EEUS","ENERBRIX","ENERGEX","ENGYAUST","EPVIC1","ERGON","ETSACOR","ETSAPWR","HAZELPWR","HTWIND","HYDROSA","HYDROTAS","INFRATIL","LONSDALE","LOYYANGA","LYGS","MACQGEN","METPL","MRYLINK1","NEMMCO","NEMRESTR","NEWGEN","NPSAIL","PACPOWER","PEAKCO","PIONEER","QTPTC","REDBANK","ROCKYPT","SECV","SITHE","SNOWY","SOLARIS","SOUTHHYD","STANWELL","TARONG","TIPSCO","WPWF","YALLNR","YALLOURN"],"is_categorical":true},"STATIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Station Identifier","examples":["AGLHAL","AGLNOW1","AGLSOM","ANGASTON","APS","BAPS","BARCALDN","BARRON","BASSLINK","BASTYAN","BAYSW","BBP31","BELLBAY","BHASZINC","BHILLGT","BLOWER","BRAEMARA","BROOKLYN","BROWNMT","BURRIN","BUTLERSG","CALLIDE","CALLIDEC","CALLIDEC1","CANUNDA1","CATHROCK","CETHANA","CHALLWF","CLOVER","CLUNY","COLNSV","DARTM","DEIBDL","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DIRECTLINK","DRYCGT","EASTCRK","EDLRGNRD","EILDON","ENERGYB","ERARING","ERG_AS","FARLEIGH","FISHER","G/STONE","GORDON","GUTHEGA","HAZEL","HUMENSW","HUMEV","HUNTVGT","INVICTA","JACKSGUL","JBUTTERS","JEERA","JEERB","KAREEYA","KEEPIT","KOOLKHAN","LADBROKE","LEM_WIL","LIDDELL","LI_WY_CA","LKBONNY1","LK_ECHO","LNGS","LONGFORD","LONSDALE","LOYYANGA","LOYYB","LUCAS2S2","LYGS","MACKAY","MACKNADE","MACKNTSH","MARIAN","MCKAY","MEADOWBK","MILLMERN","MINTARO","MM","MORNW","MP","MSTUART","MTMILLAR","MULGRAVE","MURLINKP","MURRAY","MURRAY1","MURRAY2","NEWPORT","NORTHGT","NORTHP","NPPPPS","OAKEY","OCPS","OSBORNE","PALOONA","PINDARI","PIONEER","PLANECRK","PLAYF","PLEYSTOW","PMATTAEP","PORTLAND","PORTLCN","PTH","PTINA110","PTINA220","QUARANTN","RCOURSE","REDBANK1","REECE","REPULSE","ROCHEDAL","ROMA","ROWALLAN","RPCG","RT_NSW1","RT_QLD1","RT_SA1","RT_TAS1","RT_VIC1","RUBICON","SHOALHAV","SITHE","SNOWY","SNOWY1","SNOWY2","SNOWY3","SNOWY4","SNOWY5","SNOWY6","SNOWYP","SNUG","SNWYGJP2","SOMERSET","STANWELL","STARFHILL","STHJST","STPN1","SUNCOAST","SUNSHINE","SWANBANK","TARONG","TARONGN","TARRALEA","TBLAND","TERALBA","TERMSTOR","TOMAGO","TOORAWF","TORRIS","TREVALLN","TRIBUTE","TUMUT1","TUMUT2","TUMUT3","TUNGATIN","UWS","VICSMLT","VP","VPGS","WCLASS","WG","WGULLY","WHIT1","WINDHILL","WIVENHOE","WIVENSH","WKIEWA","WONWP","WOOLNTH1","WPWF","WW","WYNDW","YABULU","YALLOURN","YAMBUK"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record within the effective date","examples":["1","51"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1998/10/29 18:03:18"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STATIONOWNER%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":32748,"decompressed_size_all_time":32466710},"visibility":"Public","trigger":"When there is a station owner change or new unit registration"},"STATIONOWNERTRK":{"package":"PARTICIPANT_REGISTRATION","pdr_config":{"mappings":[{"REPORT_NAME":"PARTICIPANT_REGISTRATION","REPORT_SUB_TYPE":"STATIONOWNERTRK","VERSION":1}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec44.htm#279"],"comment":"STATIONOWNERTRK shows the tracking for the associated object STATIONOWNER. Together, STATIONOWNERTRK and STATIONOWNER sets out the owner details of each station.","description":"STATIONOWNER is public data, and is available to all participants.\n\nSource\n\nSTATIONOWNER is updated whenever there is a change in the station owner\nor new units are registered.","primary_keys":["EFFECTIVEDATE","PARTICIPANTID","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of this record","examples":["1998/10/25 00:00:00"],"parse_csv_as_string":true,"is_date":true},"PARTICIPANTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Unique participant identifier","examples":["ACACIRET","ACLESGA","ACTEWAGL","AETVPOWR","AGLAM","AGLE","AGLES","AGLLBESS","AGLPARFQ","AGLPARFW","AGLSHYDR","AGLWBESS","ALCOA","ALCOAPA","ALDOGASF","ALNTARES","ALNTBHWF","ALSAWCAI","AMALMASP","ARARATWF","ARROW","B2PS","BALBESS","BANGOWF2","BASSLINK","BBPEM","BBPOWER","BBTHREE","BERBANK","BERBANKW","BERYBKWF","BIPCHIN","BLYTHBAT","BOCOROCK","BODWF1","BOMENSF","BORAL","BORALCMT","BOULBESS","BRCSF","BRNDBESS","BULGANA","BUNGALA1","BUNGALA2","BUNGBESS","BWFTRUST","CAPBESS","CAPEBYRN","CAPRISF","CAPTPL","CARWARP","CATHROCK","CBWF","CHALLHWF","CHERRYWF","CLARESF1","CLEANCO","CLEMGPWF","CLERMSF","CNRGY","CNUNDAWF","COALCO","COLEAMSF","COLLECWF","COLUMSF","CONTACTA","COOPGWF","COROWASF","CPEMGEN","CROOKWD","CROOKWD3","CROWLDWF","CRUDINE","CSENERGY","CSF1","CSR","CULLRGWF","CUMMINS","CUSF","DALBYSGA","DALRYMPN","DARLSF","DAYDSF","DDSF","DEATM","DEIBDL","DELTA","DIAMDGEN","DIAMOND","DIAPURWF","DIRLINKP","DISCOVER","DPNTBESS","DUBBONA","DUBBOSK","DULACCA","DUNDWF","EAINTMDY","EASTENGY","ECOGEN","EDENVALE","EDISON","EDLCSMQ","EDLGRPOP","EDLLFGN","EDLLFGQ","EDLLFGS","EDLLFGV","EDLOCI","EDLTT","EEQ","EEQGEN","EEQLILY","EEQMEWF","EEUS","ENELAUS","ENERBRIX","ENERGEX","ENERGYXM","ENGYAUST","ENGYAVIC","ENOCMASP","ENVIROGN","ENVOAKY","EPVIC1","EQMREHA1","EQMREHA2","EQMREHA3","ERGON","ERMPOWER","ESNRGY","ETSACOR","ETSAPWR","ETSAUTIL","EVERGEN","FERGUSWF","FINLEYSF","FIRMINFR","FIRMMASP","FIRMUSGD","FPC30","FRVROYAL","FSNSW","GANNBESS","GANNSF","GBATEAST","GESF","GLENROSF","GLENSF","GOON","GPENERGY","GPWF1","GRANHAWF","GREENSP","GRIDBYND","GRIFFITH","GSPOWER","GSWF1A","GSWF1B","GULLENWF","GUNNEDAH","GUNNING","GUNSYND","HALLETT","HAMISF","HAUGHTSF","HAWKES","HAYMSF","HAZELPWR","HBESS","HEPBURN","HILLSTON","HORNSDAL","HORNSDL2","HORNSPR","HTWIND","HUGSF","HWF3","HYDROPWR","HYDROSA","HYDROTAS","IEQLD","INFIGENH","INFISAGT","INFRATIL","JEMASF","JUNEESF","KABANWF","KARSF","KENNEDYE","KERANGSP","KIATAPRJ","KIATAWF","KIDSPHES","KIDSTON","KINGARSF","KOORBESS","KSFPROJT","LALLALWF","LANDFILL","LBWPLB2","LGIGEN","LIGHTSRC","LIMBESS","LIMONSF","LINGAPWF","LKBWFBES","LKBWIND","LMSENE","LMSGEN","LONSDALE","LOYYANGA","LVES","LYGS","MACINTYR","MACKAYS","MACQGEN","MANILDRA","MANNUMB","MANNUMS2","MBAHNTH","METPL","METZSF","MOKOANSF","MOLONGOP","MONDO","MOORAWF","MORANBAH","MOREEAC","MOREESF","MORTLSWF","MORTONSL","MOUSF","MRYLINK1","MTGELLWF","MTMERCER","MTMILLAR","MUGGALSP","MUNCRKSF","MUWARRA2","MWARRA","NARRABRI","NEMMCO","NEMRESTR","NEWENGSF","NEWGEN","NEWGRWF","NORPOWER","NOVAPWR","NPSAIL","NUMURKSF","NVTSF","OEBESS","OERARING","PACHYDIN","PACPOWER","PAPMICRO","PBLUESGA","PEAKCO","PIONEER","PORTADL","PORTWF","POWRSSGA","PROGREEN","PSF","PWRSYNC","PYRENEES","QGCSALE1","QPMENGY","QTPTC","RANGBESS","RATCHAC","RATCHTOW","REDBANK","RESPONSE","RIVEBESS","ROCKYPT","ROSSRVER","RYAN","RYEPARK","SALTCRK","SAPHWF1","SAVPP1","SAWCML","SEBSF","SECURENG","SECV","SERDR","SHELLNEW","SHOAL","SHUBMASP","SITHE","SLVRTN","SMCTSV","SMTHBESS","SNODE1","SNOWNTH","SNOWSTH","SNOWTOWN","SNOWY","SOLARIS","SONNMASP","SOUTHHYD","SOUTHYD2","SRSF1","STANCCWF","STANCEA","STANRET","STANWAM1","STANWELL","STARFISH","STOCKYRD","STUBB1SF","SUCROGEN","SUNRSF","SUNSPOT3","SUNTOP","TAILEM","TALL","TARALGA","TARONG","TASIRRIG","TBLANDGP","TBSOL","TELSTRAE","TIPSCO","TLTSFS","TOORAWF","TRANSGBH","TRANSGP","TRUDW","TULLYSL","ULPBESS1","UNIQLDSF","URANQNTY","VBBHMCA3","VEPL","VESTTGEN","VICBAT","VIOTAS","WAGGAOPS","WALGBESS","WANDOAN","WATERLWF","WDOWBESS","WDOWNS","WELLNTH","WEMENSF","WGWF","WHECKSON","WHILL1","WILDCATL","WINTONSF","WLWLSF1","WLWLSF2","WOLLARSF","WONTHGWF","WOODLAWN","WOOLOOGA","WPWF","WROCKWF","WSUNDAY","WTAHBESS","WYALONG","WYASF","XELIO","YALLNR","YALLOURN","YALSTHWF","YARRANSF","YARWUN","YATSF","YESSA","ZENENGEN"],"is_categorical":true},"VERSIONNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Version no of record within the effective date","examples":["1","51"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"AUTHORISEDBY":{"sql_type":"VARCHAR2(15)","pl_type":"str","mandatory":false,"comment":"User authorising record","examples":["ABENSTED","ADALGLEISH","AGORTON","AKATRAMADOS","ASALASCACERE","BATCH","BCARR","BKNOX","CASSA","CAYNSLEY","CFHAUGH","DARIARAT","DAVIDGA","DMICALLEF","DSINGH","GAURAVS","GLANDERS","JBANKS","JBEALE","JCONLIN","JEFFP","JHO","JLOVERING","JOHNB","JOYSREEM","JPLANT","JWICHER","JYANG","LHOWARTH","LUKEB","MARIAH","MARKS","MTONGOL","OKONG","PETAE","PRABOTTINI","PSINDHI","RHARVEY","RIYER2","ROBYNE","SANGEETAP","SATAN","SBONINI","SCOTT","SGNANASKANDA","SLI","SMALIK2","SNIKHAREY","SOAG","SPARUI","SVOCISANO","TOM","WVANRISTEL","WVANRISTELL"]},"AUTHORISEDDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date record authorised","examples":["1998/10/29 18:06:19"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["1999/09/15 11:32:08"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STATIONOWNERTRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":18448,"decompressed_size_all_time":17264590},"visibility":"Public","trigger":"When there is a station owner change or new unit registration"},"STPASA_CASESOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"CASESOLUTION","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#1"],"comment":"STPASA_CASESOLUTION holds one record containing results pertaining to each entire solution","description":"STPASA_CASESOLUTION is public data.\n\nSource\n\nSTPASA_CASESOLUTION is updated each STPASA run (i.e. every 2 hours).\n\nVolume\n\nRows per day: 12\n\nMb per month: \\<1","primary_keys":["RUN_DATETIME"],"indexes":[["LASTCHANGED"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CAPACITYOBJFUNCTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Objective Function from the Capacity Adequacy run","examples":["2958182.898","3572247","4436203.909"],"is_float":true},"CAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for capacity adequacy assessment. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"is_float":true},"INTERCONNECTORFLOWPENALTY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"The penalty for non-zero interconnector flow","examples":["4.64"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date and time the record was created or modified","examples":["2026/09/01 01:08:48"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"PASA\", \"MARKET\", \"Market\"])","mandatory":false,"comment":"Generation Availability to be used in LOR run (either PASA or MARKET)","examples":null,"enums":["PASA","MARKET","Market"]},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Lack of Reserve Condition (LOR) flag for the case indicates the most severe condition in the case (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)","examples":["0"],"is_boolean":true,"unsigned_int":true,"num_int_bits":8},"LORDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for LOR assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["50"],"is_float":true},"LORUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["50"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"MAXSURPLUSRESERVEOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum surplus Reserve. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"is_float":true},"OUTAGELRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Generation Availability to be used in Outage LRC run (either PASA or MARKET)","examples":["Market"]},"OUTAGELRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for outage LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["10"],"is_float":true},"OUTAGELRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"PASAVERSION":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case","examples":["7.4.4.0"]},"RELIABILITYLRCCAPACITYOPTION":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"PASA\", \"MARKET\", \"Market\"])","mandatory":false,"comment":"Generation Availability to be used in Reliability LRC run (either PASA or MARKET)","examples":null,"enums":["PASA","MARKET","Market"]},"RELIABILITYLRCDEMANDOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Specifies the Probability of Exceedence (POE) demand forecast for Reliability LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)","examples":["10"],"is_float":true},"RELIABILITYLRCUIGFOPTION":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"UIGF POE forecast availability used for this option","examples":["90"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Low Reserve Condition (LRC) flag for the case (1 - LRC in the case, 0 - No LRCs in the case) for capacity run","examples":["0","1"],"is_boolean":true},"MAXSPARECAPACITYOPTION":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum Spare Capacity. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%","examples":["0"],"unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_CASESOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":11512,"decompressed_size_all_time":12427950},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"},"STPASA_CONSTRAINTSOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"CONSTRAINTSOLUTION","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#10"],"comment":"STPASA_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.","description":"STPASA_CONSTRAINTSOLUTION is public data.\n\nSource\n\nSTPASA_CONSTRAINTSOLUTION is updated each STPASA run (i.e. every 2\nhours).\n\nVolume\n\nRows per day: 19000 (est.)\n\nMb per month: 90","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier (synonymous with GenConID)","examples":["#BBATTERY1_E1","#BRAEMAR1_E","#GREENB1_E1","#RANGEB1_E1","#WDBESS1_E1","C_S_CGBESS01_060_G","I_6F_NS_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_060_051","N>>NIL_23_22","N>>NIL_33_34","N>>NIL_39","N>>NIL_83_84_OPEN","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_996_62","N>NIL_901","N>NIL_94T","N>NIL_94T_72","N>NIL_969","N>NIL_993","N>NIL_998_18","N>NIL_9ML","N>NIL_9R4_62","N>NIL_9R6_991","N>NIL_LSDU","N>NIL_YSTX_LV","N>Q-NIL_757_758","N^^V_CNCW_1","N^^V_MLNK_1","N_BERYLSF1_ZERO","N_NIL_TE_B","Q>NIL_DRLCLB_NIL","Q>NIL_MRTA_C","Q>NIL_YLMR","Q>PWSP_PWSP_WOSP","Q^^TR_CLHA_-350","Q_B2PSBRA_8840","Q_MEWV_823_WIP1","Q_MEWV_823_WIV1","S-MAPS2-PV_0","S-MAPS3-PV_0","S-MWPS1-PV_0","S-MWPS2-PV_0","S-MWPS3-PV_0","S>NIL_NWRB2_NWRB1","SVML_ZERO","S_DC_CBG3","S_V_HEYWOOD_OFGS","TVBL_NIL_DYN","T_MRWF_GCS","V>>DDTX3_DDTX2_DDTX1","V>>N_NIL_65_66","VSML_ZERO","VS_HEY_600_TEST","VTBL_NIL","V^^N_NIL_1","V^^V_MLNK_KGTS","V^^V_NIL_KGTS","V_S_HEYWOOD_UFLS","V_S_NIL_ROCOF"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/02 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\", \"LOR\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC","LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"],"is_categorical":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["1"],"is_float":true},"CAPACITYRHS":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The RHS value in the capacity evaluation.","examples":["-0.35","5.05","0","523"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for generic constraint; 0 if not violating","examples":["5.87","0","25.97"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/01 01:08:48"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_CONSTRAINTSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":73679147,"decompressed_size_all_time":54132022040},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"},"STPASA_DUIDAVAILABILITY":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"DUIDAVAILABILITY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#19"],"comment":"This report delivers available capacity, PASA availability and given recall period for all scheduled resources. Note that for an MNSP, DUID = LINKID in the MNSP_INTERCONNECTOR table.","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM Dispatchable Unit Identifier","examples":["LK_ECHO","LYA2","LYA3","MAPS2PV1","MAPS3PV1","MEWF1","MORTLK11","MORTLK12","MREHA3","MTMILLAR","MUCRKSF1","MWPS3PV1","W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Half hour ended interval","examples":["2026/09/13 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"STPASA run, identified by the nominal start time of the run.","examples":["2026/09/12 04:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"GENERATION_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled generating unit, semi-scheduled generating unit, BDU (Gen side), WDR or MNSP.","examples":["0.002","0","125","560"],"is_float":true},"GENERATION_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.","examples":["27","560"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"GENERATION_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.","examples":["0","1","24000"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Report Creation Date Time.","examples":["2026/09/12 04:00:01"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled load or BDU(Load side).","examples":["200"],"is_float":true},"LOAD_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"PASA Availability for a scheduled load or BDU(Load side).","examples":["200"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"LOAD_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled load or BDU(Load side).","examples":["24000"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_DUIDAVAILABILITY%23FILE02%23202609010000.zip","manifest_summary":{"max_files_per_month":22,"first_month":{"year":2025,"month":7},"last_month":{"year":2026,"month":9},"compressed_size_per_month":461171352,"decompressed_size_all_time":374892561470},"visibility":"Public","trigger":"Start of each STPASA run (every hour)"},"STPASA_FNM_CASESOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_CASESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#25"],"comment":"STPASA_FNM_CASESOLUTION shows the case run details, including the available run types, LOR and Deficit condition for each case.","primary_keys":["RUN_DATETIME"],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BASE_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"DEFICITCONDITION is only set if supply deficit exists in a Zone that does NOT contain the Regional Reference Node\nDEFICITCONDITION indicates the most severe condition for the case:\nDEFICITCONDITION = 3 if deficit in BASE run, else = 2 if deficit in RELIABILITY run, else = 1 if deficit in WARNING run, else 0","is_integer":true,"unsigned_int":true,"num_int_bits":8},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"LORCONDITION is only set if supply deficit exists in a Zone that contains the Regional Reference Node\nLORCONDITION indicates the most severe condition for the case:\nLORCONDITION = 3 if deficit in BASE run, else = 2 if deficit in RELIABILITY run, else = 1 if deficit in WARNING run, else 0","is_integer":true,"unsigned_int":true,"num_int_bits":8},"PASAVERSION":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"Version of the PASA solver used to solve this case"},"RELIABILITY_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"},"WARNING_RUN_AVAILABLE":{"sql_type":"VARCHAR2(10)","pl_type":"str","mandatory":false,"comment":"YES = Available, NO = Not Available"}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_CONSTRAINTSOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_CONSTRAINTSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#31"],"comment":"STPASA_FNM_CONSTRAINTSOLUTION shows the manual or thermal constraint (created by PASA), including marginal value, violation degree, LHS and RHS.","primary_keys":["CONSTRAINTID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"columns":{"CONSTRAINTID":{"sql_type":"VARCHAR2(100)","pl_type":"pl.Categorical","mandatory":true,"comment":"Constraint identifier, either manual constraint (synonymous with GenConID) or thermal constraint created by PASA with format 'BASE_<BranchName>' or '<ContingencyID>_<BranchName>'","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BASE\", \"RELIABILITY\", \"WARNING\"])","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)","examples":null,"enums":["BASE","RELIABILITY","WARNING"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint LHS (MW)","is_float":true},"MARGINALVALUE":{"sql_type":"NUMBER(20,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Marginal Value ($/MW)","is_float":true},"RHS":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint RHS (MW)","is_float":true},"VIOLATIONDEGREE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Constraint Violation Degree (MW)","is_float":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_DUIDAVAILABILITY":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_DUIDAVAILABILITY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#37"],"comment":"STPASA_FNM_DUIDAVAILABILITY shows Available Capacity, PASA Availability and given Recall Period for all scheduled","primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME"],"columns":{"DUID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"NEM Dispatchable Unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BID_OFFERDATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date Time that the energy bid was received","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"BID_TRADINGDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Trading Date of the energy bid","examples":["2026/01/20 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"GENERATION_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled generating unit, semi-scheduled generating unit, BDU (Gen side), WDR or MNSP","is_float":true},"GENERATION_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit (MW)","is_float":true},"GENERATION_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit (Hours)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LOAD_MAX_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Available Capacity for a scheduled load or BDU (Load side) (MW)","is_float":true},"LOAD_PASA_AVAILABILITY":{"sql_type":"NUMBER(12,3)","pl_type":"pl.Float64","mandatory":false,"comment":"PASA Availability for a scheduled load or BDU (Load side) (MW)","is_float":true},"LOAD_RECALL_PERIOD":{"sql_type":"NUMBER(8,3)","pl_type":"pl.Float64","mandatory":false,"comment":"Recall Period associated with the PASA Availability for a scheduled load or BDU (Load side) (Hours)","is_float":true}},"visibility":"Public"},"STPASA_FNM_INTERCONNECTORSOLN":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_INTERCONNECTORSOLN","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#43"],"comment":"STPASA_FNM_INTERCONNECTORSOLN shows cleared Interconnector flow for the interval.","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BASE\", \"RELIABILITY\", \"WARNING\"])","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)","examples":null,"enums":["BASE","RELIABILITY","WARNING"]},"CLEAREDFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interconnector flow (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_INTERZONALSOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_INTERZONALSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#49"],"comment":"STPASA_FNM_INTERZONALSOLUTION shows cleared inter zonal flow for the interval and run type.","primary_keys":["INTERVAL_DATETIME","INTERZONALCONNECTORID","RUN_DATETIME","RUNTYPE"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"INTERZONALCONNECTORID":{"sql_type":"VARCHAR2(50)","pl_type":"pl.Categorical","mandatory":true,"comment":"InterzonalConnector Identifier","is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BASE\", \"RELIABILITY\", \"WARNING\"])","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)","examples":null,"enums":["BASE","RELIABILITY","WARNING"]},"CLEAREDFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Interzonal flow (MW)","is_float":true},"FROMZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":false,"comment":"FromZoneID of the InterZonalConnectorID","is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"TOZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"str","mandatory":false,"comment":"ToZoneID of the InterZonalConnectorID"}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_REGIONSOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_REGIONSOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#55"],"comment":"STPASA_FNM_REGIONSOLUTION shows regional demand, cleared values of resources, spare capacity, losses for each run type and intervals.","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNTYPE"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BASE\", \"RELIABILITY\", \"WARNING\"])","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)","examples":null,"enums":["BASE","RELIABILITY","WARNING"]},"BDU_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (positive) or Consumption (negative) from bidirectional units (MW)","is_float":true},"CLEAREDDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Demand (MW)","is_float":true},"CLEAREDLOSSES":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Grid Losses (MW)","is_float":true},"CLEAREDNETINTERCHANGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Net Export (positive) or Net Import (negative) (MW)","is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (MW)","is_float":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain its Regional Reference Node\nDEFICITCONDITION = 3 if deficit in BASE run\nDEFICITCONDITION = 2 if deficit in RELIABILITY run\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"DEMAND_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to most probable Demand Forecast (MW)","is_float":true},"ENERGYCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from energy-constrained resources - that is, from bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"ENERGYUNCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from non energy-constrained resources - that is, excluding bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"INITIALDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Most probable Demand Forecast adjusted by Demand Uncertainty Margin (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists in the Zone for this Region that contains its Regional Reference Node\nLORCONDITION = 3 if deficit in BASE run\nLORCONDITION = 2 if deficit in RELIABILITY run\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"SCHED_GEN_AUX_LOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Auxiliary Load adjustment to uncertainty-adjusted Bid MaxAvail of all scheduled generating units (MW)","is_float":true},"SCHED_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to Scheduled Generation Bid Max Avail (MW)","is_float":true},"SPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Spare Generation Capacity = max(0, Available Generation minus [Cleared Generation minus Cleared Net Interchange]) (MW)","is_float":true},"SS_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled solar generating units (MW)","is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled wind generating units (MW)","is_float":true},"SUPPLYDEFICIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit (MW) across at all loads in the Region = Max(0, Initial Demand minus Cleared Demand) where Cleared Demand = (Cleared Generation minus Cleared Losses minus Cleared Net Interchange).\nSupply Deficit = Supply Deficit_RRN + Supply Deficit_NonRRN","is_float":true},"SUPPLYDEFICIT_NONRRN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit across all loads in the Zone(s) that do not contain the Regional Reference Node (MW)","is_float":true},"SUPPLYDEFICIT_RRN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit across all loads in the Zone that contains the Regional Reference Node (MW)","is_float":true},"VRE_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment to most probable VRE Forecast (MW)","is_float":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_REGIONSUMMARY":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_REGIONSUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#61"],"comment":"STPASA_FNM_REGIONSUMMARY shows the summary of STPASA outcome for each region.","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain its Regional Reference Node.\nDEFICITCONDITION indicates the most severe condition:\nDEFICITCONDITION = 3 if deficit in BASE run; else\nDEFICITCONDITION = 2 if deficit in RELIABILITY run; else\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast (MW)","is_float":true},"DEMAND50_UNSCHED_GEN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast plus Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists in the Zone for this Region that contains its Regional Reference Node\nLORCONDITION indicates the most severe condition:\nLORCONDITION = 3 if deficit in BASE run; else\nLORCONDITION = 2 if deficit in RELIABILITY run; else\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"SCHED_LOAD_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled loads (MW)","is_float":true},"SCHED_SS_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled generating units, scheduled bidirectional units (Gen side) and semi-scheduled generating units, with latter capped at UIGF (MW)","is_float":true},"SCHED_SS_GEN_PASAAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid PASAAvailability of all scheduled generating units and scheduled bidirectional units (Gen side) with a Bid Recall Period less than (Interval_DateTime minus Run_DateTime) plus UIGF for all semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all solar semi-scheduled generating units (MW)","is_float":true},"SS_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all semi-scheduled generating units (MW)","is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all wind semi-scheduled generating units (MW)","is_float":true},"UNSCHED_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_ZONESOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_ZONESOLUTION","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#67"],"comment":"STPASA_FNM_ZONESOLUTION shows zone demand, cleared value of resources, spare capacity, losses for each run type and interval.","primary_keys":["INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","ZONEID"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"BASE\", \"RELIABILITY\", \"WARNING\"])","mandatory":true,"comment":"Run Type (BASE, RELIABILITY, WARNING)","examples":null,"enums":["BASE","RELIABILITY","WARNING"]},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Zone identifier","is_categorical":true},"BDU_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (positive) or Consumption (negative) from bidirectional units (MW)","is_float":true},"CLEAREDDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Demand (MW)","is_float":true},"CLEAREDLOSSES":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Grid Losses (MW)","is_float":true},"CLEAREDNETINTERCHANGE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Net Export (positive) or Net Import (negative) (MW)","is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation (MW)","is_float":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit exists and this Zone does not contain the Regional Reference Node.\nDEFICITCONDITION = 3 if deficit in BASE run\nDEFICITCONDITION = 2 if deficit in RELIABILITY run\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"DEMAND_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (increase) to most probable Demand Forecast (MW)","is_float":true},"ENERGYCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from energy-constrained resources - that is, from bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"ENERGYUNCONSTRAINED_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from non energy-constrained resources - that is, excluding bidirectional units and generating units subject to daily energy limits (MW)","is_float":true},"INITIALDEMAND":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Most probable Demand Forecast adjusted by Demand Uncertainty Margin (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists and this Zone contains the Regional Reference Node\nLORCONDITION = 3 if deficit in BASE run\nLORCONDITION = 2 if deficit in RELIABILITY run\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier of the Region containing this Zone","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCHED_GEN_AUX_LOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Auxiliary Load adjustment to uncertainty-adjusted Bid MaxAvail of all scheduled generating units (MW)","is_float":true},"SCHED_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (decrease) to Scheduled Generation Bid Max Avail (MW)","is_float":true},"SPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Spare generation capacity = max(0, Available Generation minus [Cleared Generation minus Cleared Net Interchange]) (MW)","is_float":true},"SS_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled solar generating units (MW)","is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Cleared Generation from semi-scheduled wind generating units (MW)","is_float":true},"SUPPLYDEFICIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Supply Deficit at loads = Max(0, Initial Demand minus Cleared Demand) where Cleared Demand = (Cleared Generation minus Cleared Losses minus Cleared Net Interchange) (MW)","is_float":true},"VRE_GEN_UNCERTAINTY_MARGIN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Uncertainty Margin adjustment (decrease) to most probable VRE Forecast (MW)","is_float":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_FNM_ZONESUMMARY":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"FNM_ZONESUMMARY","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#73"],"comment":"STPASA_FNM_ZONESUMMARY shows the summary of STPASA outcome for each zone.","primary_keys":["INTERVAL_DATETIME","RUN_DATETIME","ZONEID"],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the first half hour ended interval of the run","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"ZONEID":{"sql_type":"VARCHAR2(30)","pl_type":"pl.Categorical","mandatory":true,"comment":"Zone identifier","is_categorical":true},"DEFICITCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Deficit Condition (DEFICITCONDITION) > 0 if a supply deficit only exists in a Zone for this Region that does not contain the Regional Reference Node\nDEFICITCONDITION indicates the most severe condition:\nDEFICITCONDITION = 3 if deficit in BASE run; else\nDEFICITCONDITION = 2 if deficit in RELIABILITY run; else\nDEFICITCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast (MW)","is_float":true},"DEMAND50_UNSCHED_GEN":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast plus Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"Lack of Reserve Condition (LORCONDITION) > 0 if a supply deficit exists and this Zone contains the Regional Reference Node\nLORCONDITION indicates the most severe condition:\nLORCONDITION = 3 if deficit in BASE run; else\nLORCONDITION = 2 if deficit in RELIABILITY run; else\nLORCONDITION = 1 if deficit in WARNING run","is_integer":true,"unsigned_int":true,"num_int_bits":8},"REGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region identifier of the Region containing this Zone","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SCHED_LOAD_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled loads (MW)","is_float":true},"SCHED_SS_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid MaxAvail of all scheduled generating units, scheduled bidirectional units (Gen side) and semi-scheduled generating units, with latter capped at UIGF (MW)","is_float":true},"SCHED_SS_GEN_PASAAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Bid PASAAvailability of all scheduled generating units and scheduled bidirectional units (Gen side) with a Bid Recall Period less than (Interval_DateTime minus Run_DateTime) plus UIGF for all semi-scheduled generating units (MW)","is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all solar semi-scheduled generating units (MW)","is_float":true},"SS_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all semi-scheduled generating units (MW)","is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate 50% Probability of Exceedance Unconstrained Intermittent Generation Forecast (UIGF) of all wind semi-scheduled generating units (MW)","is_float":true},"UNSCHED_GEN_CAPACITYAVAIL":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Aggregate Generation Forecast of all non-scheduled and exempt generation (MW)","is_float":true}},"visibility":"Public","trigger":"Every 60 minutes"},"STPASA_INTERCONNECTORSOLN":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"INTERCONNECTORSOLN","VERSION":3}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#79"],"comment":"STPASA_INTERCONNECTORSOLN shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.","description":"STPASA_INTERCONNECTORSOLN is public so is available to all participants.\n\nSource\n\nSTPASA_INTERCONNECTORSOLN is updated each STPASA run (i.e. every 2\nhours).\n\nVolume\n\nRows per day: 576\n\nMb per month: 4","primary_keys":["INTERCONNECTORID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE","STUDYREGIONID"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector Identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/09/05 01:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/09/03 02:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\", \"LOR\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC","LOR"]},"STUDYREGIONID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":true,"comment":"Primary Region for LP Solve (or MARKET if none).","examples":["NSW1","QLD1","SA1","TAS1","VIC1"],"is_categorical":true},"CALCULATEDEXPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit","examples":["-27.59","24.44","0","975"],"is_float":true},"CALCULATEDIMPORTLIMIT":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.","examples":["-2.83","25.76","0","-1379"],"is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","examples":["0"],"is_float":true},"CAPACITYMWFLOW":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints","examples":["-7.54","6.82","0","456"],"is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for interconnector capacity; 0 if not violating","examples":["0"],"is_float":true},"EXPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Export Limit","examples":["I_6F_NS_150","I_6F_SN_150","N::N_CNCW_2","N::Q_BWMP_LDTW","N::Q_BWMP_TNT","N>>NIL_33_34","N>>NIL_39","N>>NIL_83_84_OPEN","N>NIL_LSDU","N>Q-NIL_757_758","NQ_950_TEST","N^N_KKLS_1","Q>>NIL_MRTX4_MRTX5","Q^^TR_CLHA_-350","S>>NIL_RBTU_RBTU","S>>NIL_RBTU_WEWT","S>>NIL_TWPA_TPRS","S>NIL_NWRB2_NWRB1","TVBL_NIL_DYN","V::N_DDSM_S2","V::N_LTWG_S2","V::S_SETB_TBSE_2","V>>DDMS_DDWO_DDMS","V>>DDSM_BABE_SMDD","V>>NIL_SMTX_SMTX_R5","V>>N_051+X5_65_66","V>>N_051+X5_66_65","V>>N_NIL_65_051","V>>N_NIL_65_66","VS_HEY_600_TEST","VS_V-SA_250","V^^N_BADP_1","V^^N_CNCW_1","V^^N_DDMS_1","V^^N_NIL_1","V_S_HEYWOOD_UFLS"],"is_categorical":true},"IMPORTLIMITCONSTRAINTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"ID of the constraint that sets the Interconnector Import Limit","examples":["I_6F_NS_150","N::V_DDMS","N::V_DDSM_MSDD","N>967_96L_89_S","N>>9W7_9W2_965","N>>NIL_23_22","N>>NIL_39","N>>NIL_86_85_S","N>>NIL_8U_86_S","N>>NIL_964_84_S","N>>NIL_966/1_87_S","N^^N_NIL_WGLT","N^^V_BADP_1","N^^V_BADP_DTKV_1","N^^V_CNCW_1","N^^V_MSDD2","N^^V_NIL_1","N^^V_NIL_ARWBBA","N_MBTE1_B","N_NIL_TE_B","Q:N_1078","Q>N-NIL_8L_8M","Q>NIL_757_758_ECS","Q^^N_NIL_SRAR","S:VS_800","S:V_700_HY_TEST","S>>MW2MW3_RBNW1","SA_SETB_B","SVML_FLT_130","SV_250_LKB","S_V_HEYWOOD_OFGS","V>>DDSM_EPTT_DDSM","V>>DDSM_MBEP_DDSM","V>>DDSM_SHBE_DDSM","V>>NIL_MLGT_MLGT","V>>NIL_SMTX_SMTX_R5","V>>X5_WBBA_KGBE","VTBL_NIL","V^^V_NIL_KGTS"],"is_categorical":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/09/03 02:08:47"],"parse_csv_as_string":true,"is_s_datetime":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_INTERCONNECTORSOLN%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":83126010,"decompressed_size_all_time":58752171140},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"},"STPASA_REGIONSOLUTION":{"package":"STPASA_SOLUTION","pdr_config":{"mappings":[{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":6},{"REPORT_NAME":"STPASA","REPORT_SUB_TYPE":"REGIONSOLUTION","VERSION":7}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec59.htm#88"],"comment":"STPASA_REGIONSOLUTION shows the results of the regional capacity, maximum surplus reserve and maximum spare capacity evaluations for each period of the study. Note that the RELIABILITY_LRC and OUTAGE_LRC Run Types are no longer reported from 31 July 2025.","description":"STPASA_REGIONSOLUTION is public so is available to all participants.\n\nSource\n\nSTPASA_REGIONSOLUTION is updated each STPASA run (i.e every 2 hours).\n\nVolume\n\nRows per day: 480\n\nMb per month: 8","primary_keys":["INTERVAL_DATETIME","REGIONID","RUN_DATETIME","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"End date time of the interval.","examples":["2026/09/02 04:30:00"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this run, identified by the nominal start time of the run.","examples":["2026/09/01 01:00:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\", \"LOR\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC","LOR"]},"AGGREGATECAPACITYAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities offered by all Scheduled units and Availability of all semi-scheduled units limited by MAXAVAIL in a given Region for a given PERIODID","examples":["1945.13","2019","16682.59","13580"],"is_float":true},"AGGREGATEPASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"Sum of PASAAVAILABILITY for all scheduled generating units and scheduled bidirectional units (Gen side) with a Recall_Period <= 24 hours plus the sum of Unconstrained Intermittent Generation Forecasts (UIGF) for all semi-scheduled generating units. For the RELIABILITY_LRC and OUTAGE_LRC runs, UIGF is the POE90 forecast. For the LOR Run, UIGF is the POE50 forecast. Note that the RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025. From March 2026, AGGREGATEPASAAVAILABILITY changes from that with Recall_Period <= 24 to that achievable by the relevant INTERVAL_DATETIME if recalled at the start of the run.","examples":["1979","18320"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"AGGREGATESCHEDULEDLOAD":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of MAXAVAIL quantities bid by of all Scheduled Loads in a given Region for a given PERIODID.","examples":["0","1"],"is_float":true},"CALCULATEDLOR1LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR1 used. Can be static value or calculated value if an interconnector is a credible contingency","examples":["354.29701","582","1579.48329","1430"],"is_float":true},"CALCULATEDLOR2LEVEL":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Region Reserve Level for LOR2 used. Can be static value or calculated value if an interconnector is a credible contingency","examples":["178.297","435","849.48329","730"],"is_float":true},"CAPACITYREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Demand + Reserve requirements (MW). This field is not populated after 30 July 2025.","is_float":true},"CONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"Aggregate generation + WDR capacity from Energy Constrained plant subjected to restrictions due to network constraints.","examples":["0","1","2782"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"DEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"10% Probability of Exceedance demand forecast.","examples":["371","9289"],"is_float":true},"DEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"50% Probability of Exceedance demand forecast.","examples":["334","9001"],"is_float":true},"DEMAND90":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"90% Probability of Exceedance demand forecast.","examples":["297","8713"],"is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["334","9125"],"is_float":true},"ENERGYREQDEMAND10":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Energy (GWh) required for this energy block based on the 10% probability of exceedance demand. Listed in the first interval of the energy block","examples":["25.24","0","174.02"],"is_float":true},"ENERGYREQDEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of: (Region Demand50)/Period (sum by trading day, entered in first period of trading day, GWh).","examples":["23.58","0","168.66"],"is_float":true},"FUM":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecasting Uncertainty Measure. MW value of reserve calculated as defined in the Reserve Level Declaration Guidelines","examples":["230.1158","0","844.8202"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Date time this record was created.","examples":["2026/09/01 01:08:48"],"parse_csv_as_string":true,"is_s_datetime":true},"LCR":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Largest Credible Risk. MW value for highest credible contingency","examples":["172.363","435","849.48329","730"],"is_float":true},"LCR2":{"sql_type":"NUMBER(16,6)","pl_type":"pl.Float64","mandatory":false,"comment":"Two Largest Credible Risks. MW value for highest two credible contingencies.","examples":["333.529","582","1579.48329","1430"],"is_float":true},"LOR_SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for semi-scheduled units for the region for the LOR run. Semi-scheduled generation is constrained by both System Normal and Outage constraints, and incorporate MAXAVAIL limits.","examples":["169.13","243","3832.64","2991"],"is_float":true},"LORCONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.UInt8","mandatory":false,"comment":"The LOR Condition determined from the Maximum Spare Capacity value: 0 - no condition, 1 - LOR1 condition, 2 - LOR2 condition, 3 - LOR3 condition","examples":["0"],"is_integer":true,"unsigned_int":true,"num_int_bits":8},"LORNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the LOR assessment","examples":["-2.07","39.33","-438","-2518"],"is_float":true},"MAXSPARECAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Spare Capacity (MW) evaluated for this region. Calculated for each region in turn. This value reflects Regional LOR reserve.","examples":["957.35","1344","8051.87","5389"],"is_float":true},"NETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net export (MW) out of this region in the LOR evaluation. Export if > 0, Import if < 0. This value is the same as LORNETINTERCHANGEUNDERSCARCITY.","examples":["-2.07","39.33","-438","-2518"],"is_float":true},"SEMISCHEDULEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for semi-scheduled units for the region. For RELIABILITY_LRC run, semi-scheduled generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, semi-scheduled generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["169.13","243","3832.64","2991"],"is_float":true},"SS_SOLAR_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for solar for the region. For RELIABILITY_LRC run solar generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run solar generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["0.03","0","16","1931"],"is_float":true},"SS_SOLAR_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for solar for the region. For RELIABILITY_LRC run, solar generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, solar generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.This value is the same as SS_SOLAR_CAPACITY.","examples":["0.03","0","16","1931"],"is_float":true},"SS_SOLAR_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained Intermittent Generation Forecast for solar for the region. For RELIABILITY_LRC and OUTAGE_LRC run this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run this is the POE50 forecast","examples":["0.03","0","1095","2935"],"is_float":true},"SS_WIND_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast for wind for the region. For RELIABILITY_LRC run wind generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run wind generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.","examples":["32.86","243","3515.18","2991"],"is_float":true},"SS_WIND_CLEARED":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Constrained generation forecast (MW) for wind for the region. For RELIABILITY_LRC run, wind generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, wind generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.This value is the same as SS_WIND_CAPACITY.","examples":["32.86","243","3515.18","2991"],"is_float":true},"SS_WIND_UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Unconstrained Intermittent Generation Forecast for wind for the region. For RELIABILITY_LRC and OUTAGE_LRC run this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run this is the POE50 forecast","examples":["115.35","243","4374.57","1652"],"is_float":true},"SURPLUSCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional surplus capacity (MW), +/- values indicate surplus/deficit capacity respectively. This value reflects Regional LOR reserve.","examples":["957.35","1344","8051.87","5389"],"is_float":true},"SURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional surplus reserve (MW). This value also reflects Regional LOR reserve. Note: For LOR runs, RESERVEREQ requirement input is not used.","examples":["957.35","1344","8051.87","5389"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["0","1","365"],"is_float":true},"UIGF":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["169.13","243","5773.68","3880"],"is_float":true},"UNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"Aggregate generation + WDR capacity from Non-Energy Constrained plant subjected to restrictions due to network constraints.","examples":["1204","9409"],"is_integer":true,"unsigned_int":true,"num_int_bits":64},"WDR_AVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) availability in MW.","examples":["0","1"],"is_float":true},"WDR_CAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) capacity in MW.","examples":["0","1"],"is_float":true},"WDR_PASAAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Wholesale Demand Response (WDR) PASA availability in MW.","examples":["0","1"],"is_float":true},"MAXSURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Maximum Surplus Reserve (MW) evaluated for this region from LRC runs. This field is no longer populated.","unused":true,"is_float":true},"MSRNETINTERCHANGEUNDERSCARCITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Net interconnector flow from the region for this interval from the MSR assessment. This field is no longer populated.","unused":true,"is_float":true},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"Regional reserve condition from LRC run. This field is not populated after 30 July 2025.","unused":true,"is_integer":true,"num_int_bits":8},"RESERVEREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Reserve Requirement (MW). This field is not populated after 30 July 2025.","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23STPASA_REGIONSOLUTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":70921774,"decompressed_size_all_time":124951225600},"visibility":"Public","trigger":"After each STPASA run (every 2 hours)"},"STPASA_SYSTEMSOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1220"],"comment":"STPASA_SYSTEMSOLUTION is obsolete from 2005 End of Year Release. For solution information, see Region solution tables.\nSTPASA_SYSTEMSOLUTION showed the results of the system capacity evaluations for each interval of the study.","description":"STPASA_SYSTEMSOLUTION is public data.\n\nSource\n\nSTPASA_SYSTEMSOLUTION is updated each STPASA run (half-hourly).\n\nVolume\n\nRows per day: 48\n\nMb per month: \\<1","unused":true,"primary_keys":["INTERVAL_DATETIME"],"indexes":[["LASTCHANGED"],["RUN_DATETIME"]],"columns":{"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"CONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"System energy constrained capacity MW subject to energy and network constraints","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RESERVECONDITION":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"The system reserve condition: 0 Adequate, 1 LRC","is_boolean":true},"RESERVEREQ":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"System total reserve requirement","is_float":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"SURPLUSCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"System capacity surplus MW, +/- values indicate surplus/deficit capacity","is_float":true},"SURPLUSRESERVE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"System reserve surplus MW, +/- values indicate surplus/deficit reserve","is_float":true},"SYSTEMDEMAND50":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Demand 50% PoE","is_float":true},"UNCONSTRAINEDCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"System energy unconstrained capacity MW subject to energy and network constraints","is_float":true}},"visibility":"Public","trigger":"Each ST PASA run"},"STPASA_UNITSOLUTION":{"package":"HISTORICAL TABLES","documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1231"],"comment":"STPASA_UNITSOLUTION shows the unit results from the capacity evaluations for each period of the study.","description":"STPASA_UNITSOLUTION was discontinued in the End Year 2005 MMS Release.\nSee Change Notice 512c for further details.\n\n \n\nSTPASA_UNITSOLUTION is confidential data.\n\nSource\n\nSTPASA_UNITSOLUTION is updated each STPASA run (i.e. every 2 hours).","unused":true,"primary_keys":["DUID","INTERVAL_DATETIME","RUN_DATETIME","RUNTYPE"],"indexes":[["LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable unit Identifier","examples":["W/HOE#2"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"INTERVAL_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"The unique identifier for the interval within this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Unique Timestamp Identifier for this study","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"RUNTYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"RELIABILITY_LRC\", \"OUTAGE_LRC\"])","mandatory":true,"comment":"Type of run. Values are RELIABILITY_LRC and OUTAGE_LRC","examples":null,"enums":["RELIABILITY_LRC","OUTAGE_LRC"]},"CAPACITYAVAILABLE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"The available MW capacity for the period","is_float":true},"CAPACITYMARGINALVALUE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment marginal value, 0 if not binding","is_float":true},"CAPACITYVIOLATIONDEGREE":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Capacity adequacy assessment violation degree for unit capacity; 0 if not violating","is_float":true},"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":false,"comment":"Connection point identifier","is_categorical":true},"ENERGYAVAILABLE":{"sql_type":"NUMBER(10,0)","pl_type":"pl.Int64","mandatory":false,"comment":"The energy limit (MWH) over this energy block for the energy constrained unit","is_integer":true,"num_int_bits":64},"ENERGYCONSTRAINED":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"0 if not energy constrained, 1 if energy constrained for this energy block","is_boolean":true},"EXPECTEDMAXCAPACITY":{"sql_type":"NUMBER(12,2)","pl_type":"pl.Float64","mandatory":false,"comment":"Max MW capacity that can be obtained in case of capacity scarcity from units subject to network and energy constraints.","is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last changed date of this record","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true},"PASAAVAILABILITY":{"sql_type":"NUMBER(12,0)","pl_type":"pl.UInt64","mandatory":false,"comment":"The physical plant capability including any capability that can be made available within 24 hrs","is_integer":true,"unsigned_int":true,"num_int_bits":64}},"visibility":"Private","trigger":"Each ST PASA run"},"TRADINGINTERCONNECT":{"package":"TRADING_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"INTERCONNECTORRES","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec61.htm#7"],"comment":"TRADINGINTERCONNECT shows the Interconnector flows for the 5 minutes Trading Interval.\nPrior to 5 Minute Settlements, this was the average of the six 5 minute dispatch intervals within the 30 minute period.","description":"TRADINGINTERCONNECT is public data, and is available to all\nparticipants.\n\nSource\n\nTRADINGINTERCONNECT is updated half hourly.","primary_keys":["INTERCONNECTORID","PERIODID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"INTERCONNECTORID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Interconnector identifier","examples":["N-Q-MNSP1","NSW1-QLD1","T-V-MNSP1","V-S-MNSP1","V-SA","VIC1-NSW1"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period number where 1 represents the trading interval ending at 00:05 AEST","examples":["1","167"],"is_integer":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date that this data applies to","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"METEREDMWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average of the metered MW flow from the start of each dispatch interval.","examples":["-0.3","0.3","0","1044"],"is_float":true},"MWFLOW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Calculated MW Flow from SPD","examples":["-0.6","3.8","0","1035"],"is_float":true},"MWLOSSES":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"MW losses at calculated MW flow","examples":["-0.01","0.01","0","114"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23TRADINGINTERCONNECT%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":756101,"decompressed_size_all_time":542186430},"visibility":"Public","trigger":"Every 30 minutes on price update"},"TRADINGLOAD":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":1},{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"UNIT_SOLUTION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1240"],"comment":"TRADINGLOAD shows half-hourly average dispatch levels, including fields to handle the Ancillary Services functionality.","description":"Source\n\nOwn (confidential) TRADINGLOAD data updates half hourly, with public\navailability of all data on next day.","unused":true,"primary_keys":["DUID","PERIODID","RUNNO","SETTLEMENTDATE","TRADETYPE"],"indexes":[["LASTCHANGED"],["DUID","LASTCHANGED"]],"columns":{"DUID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Dispatchable Unit Identifier","examples":["ADPBA1G","ADPBA1L","ADPPV1","AGLHAL","AGLSOM","ANGAST1","APD01","ARWF1","ASNAES1","ASNBRL1","ASNENC1","ASQENC1","ASSENC1","ASTFG1V1","ASTHYD1","BALBG1","BALBL1","BALDHWF1","BANGOWF1","BANGOWF2","BANN1","BARCALDN","BARKIPS1","BARRON-1","BARRON-2","BASTYAN","BBTHREE1","BBTHREE2","BBTHREE3","BDL01","BDL02","BERYLSF1","BLOWERNG","BLUFF1","BNGSF1","BNGSF2","BOCORWF1","BODWF1","BOMENSF1","BRAEMAR1","BRAEMAR2","BRAEMAR3","BRAEMAR5","BRAEMAR6","BRAEMAR7","BROKENH1","BRYB1WF1","BULBESG1","BULBESL1","BULGANA1","BW01","BW02","BW03","BW04","CALL_B_1","CALL_B_2","CETHANA","CG1","CG2","CG3","CG4","CHILDSF1","CHYTWF1","CLARESF1","CLEMGPWF","CLERMSF1","COHUNSF1","COLEASF1","COLWF01","COOPGWF1","CPP_3","CPP_4","CPSA","CROOKWF2","CROWLWF1","CRURWF1","CRWASF1","CSPVPS1","CTHLWF1","DALNTH01","DALNTHL1","DARLSF1","DARTM1","DAYDSF1","DDPS1","DDSF1","DEVILS_G","DG_NSW1","DG_QLD1","DG_SA1","DG_TAS1","DG_VIC1","DRYCGT1","DRYCGT2","DRYCGT3","DUNDWF1","DUNDWF2","DUNDWF3","EILDON1","EILDON2","ELAINWF1","EMERASF1","ER01","ER02","ER03","ER04","FINLYSF1","FISHER","GANGARR1","GANNBG1","GANNBL1","GANNSF1","GLRWNSF1","GNNDHSF1","GOONSF1","GORDON","GRANWF1","GSTONE1","GSTONE2","GSTONE3","GSTONE4","GSTONE5","GSTONE6","GULLRSF1","GULLRWF1","GULLRWF2","GUNNING1","GUTHEGA","HALLWF1","HALLWF2","HAMISF1","HAUGHT11","HAYMSF1","HDWF1","HDWF2","HDWF3","HPRG1","HPRL1","HUMENSW","HUMEV","HVGTS","JBUTTERS","JEMALNG1","JLA01","JLA02","JLA03","JLA04","JLB01","JLB02","JLB03","JUNEESF1","KAREEYA1","KAREEYA2","KAREEYA3","KAREEYA4","KARSF1","KEPSF1","KEPWF1","KIAMSF1","KIATAWF1","KPP_1","KSP1","LADBROK1","LADBROK2","LBBG1","LBBL1","LD01","LD02","LD03","LD04","LEM_WIL","LGAPWF1","LILYSF1","LIMOSF11","LIMOSF21","LI_WY_CA","LKBONNY2","LKBONNY3","LK_ECHO","LNGS1","LNGS2","LONSDALE","LOYYB1","LOYYB2","LYA1","LYA2","LYA3","LYA4","MACARTH1","MACKNTSH","MANSLR1","MAPS2PV1","MARYRSF1","MCKAY1","MEADOWBK","MERCER01","MEWF1","MIDDLSF1","MINTARO","MOLNGSF1","MOORAWF1","MOREESF1","MORTLK11","MORTLK12","MP1","MP2","MPP_1","MPP_2","MSTUART1","MSTUART2","MSTUART3","MTGELWF1","MURRAY","MUSSELR1","MUWAWF1","MWPS1PV1","MWPS2PV1","MWPS3PV1","MWPS4PV1","NBHWF1","NEVERSF1","NPS","NUMURSF1","NYNGAN1","OAKEY1","OAKEY1SF","OAKEY2","OAKEY2SF","OAKLAND1","OSB-AG","PARSF1","POAT110","POAT220","POR01","POR03","PPCCGT","PTSTAN1","PUMP1","PUMP2","QPS1","QPS2","QPS3","QPS4","QPS5","REECE1","REECE2","ROMA_7","ROMA_8","RRSF1","RT_NSW1","RT_NSW2","RT_NSW3","RT_NSW4","RT_NSW5","RT_NSW6","RT_QLD1","RT_SA1","RT_SA2","RT_SA3","RT_SA4","RT_SA5","RT_SA6","RT_TAS1","RT_VIC1","RT_VIC10","RT_VIC11","RT_VIC12","RT_VIC2","RT_VIC3","RT_VIC4","RT_VIC5","RT_VIC6","RT_VIC7","RT_VIC8","RT_VIC9","RUGBYR1","SALTCRK1","SAPHWF1","SATGS1","SHGEN","SHPUMP","SITHE01","SMCSF1","SNOWNTH1","SNOWSTH1","SNOWTWN1","SNOWYGJP","SNOWYP","SNUG1","SRSF1","STAN-1","STAN-2","STAN-3","STAN-4","STOCKYD1","STWF1","SUNRSF1","SUNTPSF1","SWAN_E","TALWA1","TARALGA1","TARONG#1","TARONG#2","TARONG#3","TARONG#4","TARRALEA","TBSF1","TNPS1","TORRA1","TORRA3","TORRB1","TORRB2","TORRB3","TORRB4","TREVALLN","TRIBUTE","TUMUT3","TUNGATIN","TVCC201","TVPP104","UPPTUMUT","URANQ11","URANQ12","URANQ13","URANQ14","VBBG1","VBBL1","VENUS1","VP5","VP6","VPGS1","VPGS2","VPGS3","VPGS4","VPGS5","VPGS6","VSNEL2S1","VSNSN1V1","VSQHT1V1","VSSAE1V1","VSSEL1V1","VSSSE1V1","VSSSH1S1","VSVEL2S1","W/HOE#1","W/HOE#2","WAGGNSF1","WANDBG1","WANDBL1","WARWSF1","WARWSF2","WATERLWF","WELLSF1","WEMENSF1","WGWF1","WHITSF1","WINTSF1","WKIEWA1","WKIEWA2","WOODLWN1","WRSF1","WRWF1","YABULU","YABULU2","YARANSF1","YARWUN_1","YATSF1","YENDWF1","YWPS1","YWPS2","YWPS3","YWPS4"],"warnings":["This column may contain funny characters such as / (slash) or # (hash). This may break hive-style partitioning.\n"],"is_categorical":true},"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period Identifier","examples":["1","3"],"is_integer":true,"num_int_bits":16},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date that this data applies to","examples":["2021/09/01 00:30:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"TRADETYPE":{"sql_type":"NUMBER(2,0)","pl_type":"pl.Int8","mandatory":true,"comment":"Not used","examples":["0"],"unused":true,"is_integer":true,"num_int_bits":8},"AVAILABILITY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Bid energy availability","examples":["0.04","0","5","1475"],"is_float":true},"INITIALMW":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average Initial MW at start of each period","examples":["-0.1","0.01","0","603"],"warnings":["In AEMO data, datetimes usually refer to the end of an interval. Power values usually do too. However this column refers to the start of the interval. So you need to subtract 5 minutes from `SETTLEMENTDATE` to align it with `INITIALMW`.\n"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2021/09/01 00:25:04"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average 5 min lower dispatch","examples":["0.02","0","1","25"],"is_float":true},"LOWER6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average60 sec lower dispatch","examples":["0.14","0","1","61"],"is_float":true},"LOWER60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average 60 sec lower dispatch","examples":["1.33","0","1","45"],"is_float":true},"LOWERREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation reserve target","examples":["0.01","0","1","30"],"is_float":true},"RAISE5MIN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average 5 min raise dispatch","examples":["0.33","0","1","61"],"is_float":true},"RAISE6SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average 6 sec raise dispatch","examples":["0.33","0","1","79"],"is_float":true},"RAISE60SEC":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average 60 sec raise dispatch","examples":["0.33","0","1","115"],"is_float":true},"RAISEREG":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation reserve target","examples":["0.33","0","1","57"],"is_float":true},"RAMPDOWNRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average ramp down rate","examples":["0.18","0","60","41760"],"is_float":true},"RAMPUPRATE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average ramp up rate","examples":["1.16","0","60","41760"],"is_float":true},"SEMIDISPATCHCAP":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Boolean","mandatory":false,"comment":"Boolean representation flagging if the Target is Capped","examples":["0","1"],"is_boolean":true},"TOTALCLEARED":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average total MW dispatched over period","examples":["0.04","0","1","720"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_TRADINGLOAD_202109010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":9},"compressed_size_per_month":7036194,"decompressed_size_all_time":4103911400},"visibility":"Private & Public Next-Day","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 30 minutes"},"TRADINGPRICE":{"package":"TRADING_DATA","pdr_config":{"mappings":[{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"PRICE","VERSION":2},{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"PRICE","VERSION":3}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec61.htm#16"],"comment":"TRADINGPRICE sets out 5 minutes spot market price, including fields to handle the Ancillary Services functionality. If prices are adjusted, the final price is recorded in the regional reference price (RRP) field with price before adjustment recorded in the regional original price (ROP) field.\nPrior to 5 Minute Settlements, this was half-hourly spot market values, which was calculated as the average of the six 5 minute dispatch intervals within the 30 minute period.","description":"TRADINGPRICE data is public, so is available to all participants.\n\nSource\n\nTRADINGPRICE updates every 30 minutes.\n\nNotes\n\nINVALIDFLAG\n\nThe INVALIDFLAG field is used to indicate whether the Trading interval\nprice has been adjusted after the trading interval was completed. On a\nvery restricted set of events, the market rules allow a dispatch price\n(5 min) to be adjusted on the next business day, and, when this occurs,\nthe corresponding trading interval price for that region is also\nadjusted and marked as adjusted with INVALIDFLAG of 'A'.\n\nThe INVALIDFLAG = 'Y' only applies to historical periods when not all\nsix of the 5-minute dispatch intervals were run in the trading interval.\nSystem changes implemented on 30 September 2001 mean this situation no\nlonger occurs since missing dispatch intervals are automatically\npopulated from a previous interval.\n\nIf the INVALIDFLAG field = '0', the price was not adjusted and all six\ndispatch intervals are present.\n\nPrices\n\nThere is no field in the TRADINGPRICE table (or the MMS data model\nanywhere) telling you that the price is provisional or final. The only\nreliable method is to ensure that the trading date is at least 2\nbusiness days old.","primary_keys":["PERIODID","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Period number where 1 represents the trading interval ending at 00:05 AEST","examples":["1","200"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Run No","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date that this data applies to","examples":["2026/09/01 00:05:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"EEP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Excess energy price where negative average","examples":["0"],"is_float":true},"INVALIDFLAG":{"sql_type":"VARCHAR2(1)","pl_type":"pl.Categorical","mandatory":false,"comment":"Indicates when the Trading interval price has been adjusted after the trading interval was completed","examples":["0"]},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2026/09/01 00:00:07"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.01","0"],"is_float":true},"LOWER1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Lower 1Sec Price - RegionSolution element L1Price attribute","examples":["0.01","0"],"is_float":true},"LOWER5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","0.25"],"is_float":true},"LOWER5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.25"],"is_float":true},"LOWER6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","0.38"],"is_float":true},"LOWER6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","0.38"],"is_float":true},"LOWER60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.38"],"is_float":true},"LOWERREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","1","50"],"is_float":true},"LOWERREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","1","50"],"is_float":true},"PRICE_STATUS":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"NOT FIRM\", \"FIRM\"])","mandatory":false,"comment":"Status of regional prices for this dispatch interval \"NOT FIRM\" or \"FIRM\"","examples":null,"enums":["NOT FIRM","FIRM"]},"RAISE1SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise1Sec Regional Original Price - uncapped/unfloored and unscaled","examples":["0.01","0","0.04"],"is_float":true},"RAISE1SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Raise 1Sec Price - R1Price attribute after capping/flooring","examples":["0.01","0","0.04"],"is_float":true},"RAISE5MINROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","0.36"],"is_float":true},"RAISE5MINRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.36"],"is_float":true},"RAISE6SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0","0.38"],"is_float":true},"RAISE6SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0","0.38"],"is_float":true},"RAISE60SECROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","0.38"],"is_float":true},"RAISE60SECRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","0.38"],"is_float":true},"RAISEREGROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Original regional price - prior to APC or VoLL overrides applied","examples":["0.01","1","15.5","10"],"is_float":true},"RAISEREGRRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["0.01","1","15.5","10"],"is_float":true},"ROP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional Original Price. The price before any adjustments were made","examples":["-0.04","0.01","0","90"],"is_float":true},"RRP":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional reference price for this dispatch period","examples":["-0.04","0.01","0","90"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23TRADINGPRICE%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"compressed_size_per_month":681072,"decompressed_size_all_time":564521550},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 30 minutes on price update"},"TRADINGREGIONSUM":{"package":"HISTORICAL TABLES","pdr_config":{"mappings":[{"REPORT_NAME":"TRADING","REPORT_SUB_TYPE":"REGIONSUM","VERSION":4}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65.htm#1251","https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec65_1.htm"],"comment":"TRADINGREGIONSUM sets out the half-hourly average regional demand and frequency control services. TRADINGREGIONSUM includes fields for the Raise Regulation and Lower Regulation Ancillary Services plus improvements to demand calculations.","description":"TRADINGREGIONSUM is public data, and is available to all participants.\n\nSource\n\nTRADINGREGIONSUM is updated every 30 minutes.","unused":true,"primary_keys":["PERIODID","REGIONID","RUNNO","SETTLEMENTDATE"],"indexes":[["LASTCHANGED"]],"columns":{"PERIODID":{"sql_type":"NUMBER(3,0)","pl_type":"pl.Int16","mandatory":true,"comment":"Trading interval identifier within settlement day.","examples":["1","48"],"is_integer":true,"num_int_bits":16},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":true,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"RUNNO":{"sql_type":"NUMBER(3,0)","pl_type":"pl.UInt16","mandatory":true,"comment":"Dispatch run no.","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"SETTLEMENTDATE":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Date that this data applies to","examples":["2021/09/01 00:30:00"],"warnings":["Despite what the name suggests, this is a datetime, not a date."],"parse_csv_as_string":true,"is_s_datetime":true},"AVAILABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"The available generation in the Region for the interval","examples":["2010.81","2445","13496.75","12941"],"is_float":true},"CLEAREDSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of cleared generation and import for region","examples":["698.2","991","9080.9","8142"],"is_float":true},"DEMAND_AND_NONSCHEDGEN":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).","examples":["710.82","1253","9130.59","8490"],"is_float":true},"DEMANDFORECAST":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Forecast demand for region","examples":["-0.04","0.01","-2","18"],"is_float":true},"DISPATCHABLEGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Averaged generation dispatched in region","examples":["584.21","932","8847.84","8141"],"is_float":true},"DISPATCHABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Averaged load dispatched in region","examples":["0.02","0","1","311"],"is_float":true},"EXCESSGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average excess generation in region","examples":["0"],"is_float":true},"INITIALSUPPLY":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Sum of initial generation and import for region","examples":["713.9","1042","9019.49","6858"],"is_float":true},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Last date and time record changed","examples":["2021/09/01 00:25:04"],"parse_csv_as_string":true,"is_s_datetime":true},"LOWER5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 5 min local dispatch","examples":["0.5","0","1","102"],"is_float":true},"LOWER6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 6 sec local dispatch","examples":["1.33","0","5","129"],"is_float":true},"LOWER60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower 60 sec local dispatch","examples":["0.53","0","5","170"],"is_float":true},"LOWERREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Lower Regulation local dispatch","examples":["0.83","0","1","91"],"is_float":true},"NETINTERCHANGE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Average energy transferred over interconnector","examples":["-0.23","2.14","-40","178"],"is_float":true},"RAISE5MINLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 5 min local dispatch","examples":["0.21","0","6","203"],"is_float":true},"RAISE6SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 6 sec local dispatch","examples":["7.47","18","312.28","289"],"is_float":true},"RAISE60SECLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise 60 sec local dispatch","examples":["2.04","1","276.82","258"],"is_float":true},"RAISEREGLOCALDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Raise Regulation local dispatch","examples":["0.33","0","3","112"],"is_float":true},"TOTALDEMAND":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Total demand for region","examples":["657.05","636","9068.73","7042"],"is_float":true},"TOTALINTERMITTENTGENERATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Allowance made for non-scheduled generation in the demand forecast (MW).","examples":["0.86","3","426.37","379"],"is_float":true},"UIGF":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).","examples":["16.83","267","2762.96","1574"],"is_float":true},"AVAILABLELOAD":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used","examples":["8.33","0","5","311"],"unused":true,"is_float":true},"LOWER5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW dispatch","unused":true,"is_float":true},"LOWER5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min MW imported","unused":true,"is_float":true},"LOWER5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 5 min","unused":true,"is_float":true},"LOWER5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min local requirement","unused":true,"is_float":true},"LOWER5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 5 min","unused":true,"is_float":true},"LOWER5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 5 min total requirement","unused":true,"is_float":true},"LOWER5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 5 min","unused":true,"is_float":true},"LOWER5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 5 min requirement","unused":true,"is_float":true},"LOWER6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW dispatch","unused":true,"is_float":true},"LOWER6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec MW imported","unused":true,"is_float":true},"LOWER6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 sec local requirement","unused":true,"is_float":true},"LOWER6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 6 sec total requirement","unused":true,"is_float":true},"LOWER6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 6 sec","unused":true,"is_float":true},"LOWER6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 6 seconds requirement","unused":true,"is_float":true},"LOWER60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW dispatch","unused":true,"is_float":true},"LOWER60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec MW imported","unused":true,"is_float":true},"LOWER60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 sec local requirement","unused":true,"is_float":true},"LOWER60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower 60 sec total requirement","unused":true,"is_float":true},"LOWER60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of lower 60 sec","unused":true,"is_float":true},"LOWER60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower 60 seconds requirement","unused":true,"is_float":true},"LOWERREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation MW imported","unused":true,"is_float":true},"LOWERREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation local requirement","unused":true,"is_float":true},"LOWERREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg local requirement","unused":true,"is_float":true},"LOWERREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Lower Regulation total requirement","unused":true,"is_float":true},"LOWERREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Lower Reg requirement","unused":true,"is_float":true},"RAISE5MINDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW dispatch","unused":true,"is_float":true},"RAISE5MINIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min MW imported","unused":true,"is_float":true},"RAISE5MINLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 5 min","unused":true,"is_float":true},"RAISE5MINLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min local requirement","unused":true,"is_float":true},"RAISE5MINPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 5 min","unused":true,"is_float":true},"RAISE5MINREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 5 min total requirement","unused":true,"is_float":true},"RAISE5MINSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 5 min","unused":true,"is_float":true},"RAISE5MINVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 5 min requirement","unused":true,"is_float":true},"RAISE6SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW dispatch","unused":true,"is_float":true},"RAISE6SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec MW imported","unused":true,"is_float":true},"RAISE6SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 sec local requirement","unused":true,"is_float":true},"RAISE6SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 6 sec total requirement","unused":true,"is_float":true},"RAISE6SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 6 sec","unused":true,"is_float":true},"RAISE6SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 6 seconds requirement","unused":true,"is_float":true},"RAISE60SECDISPATCH":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW dispatch","unused":true,"is_float":true},"RAISE60SECIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec MW imported","unused":true,"is_float":true},"RAISE60SECLOCALPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Local price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 sec local requirement","unused":true,"is_float":true},"RAISE60SECPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Regional price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise 60 sec total requirement","unused":true,"is_float":true},"RAISE60SECSUPPLYPRICE":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Supply price of raise 60 sec","unused":true,"is_float":true},"RAISE60SECVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise 60 seconds requirement","unused":true,"is_float":true},"RAISEREGIMPORT":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation MW imported","unused":true,"is_float":true},"RAISEREGLOCALREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation local requirement","unused":true,"is_float":true},"RAISEREGLOCALVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg local requirement","unused":true,"is_float":true},"RAISEREGREQ":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Raise Regulation total requirement","unused":true,"is_float":true},"RAISEREGVIOLATION":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Not used since Dec 2003. Violation (MW) of Raise Reg requirement","unused":true,"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2021/MMSDM_2021_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_TRADINGREGIONSUM_202109010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2021,"month":9},"compressed_size_per_month":524537,"decompressed_size_all_time":399634210},"visibility":"Public","warnings":[{"msg":"1 second, 6 second, 5 minute, 60 second and regulation refer to types of [FCAS](../../guide/market_design.md#what-is-fcas) markets.","level":"tip"}],"trigger":"Every 30 minutes","pagination":["Elec65_1.htm"]},"TRANSMISSIONLOSSFACTOR":{"package":"MARKET_CONFIG","pdr_config":{"mappings":[{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"TRANSMISSIONLOSSFACTOR","VERSION":1},{"REPORT_NAME":"MARKET_CONFIG","REPORT_SUB_TYPE":"TRANSMISSIONLOSSFACTOR","VERSION":2}],"transaction_type":"INSERT-UPDATE","row_filter_type":"LASTCHANGED"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec33.htm#124"],"comment":"TRANSMISSIONLOSSFACTOR shows the Transmission Loss factors applied at each connection point.","description":"TRANSMISSIONLOSSFACTOR is public data, and is available to all\nparticipants.\n\nSource\n\nTRANSMISSIONLOSSFACTOR updates when new connection points are created or\nloss factors change.","primary_keys":["CONNECTIONPOINTID","EFFECTIVEDATE","VERSIONNO"],"indexes":[["LASTCHANGED"]],"columns":{"CONNECTIONPOINTID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Categorical","mandatory":true,"comment":"Connection Point ID","examples":["QASSHU01","STB31T","VJL21W","VMWF"],"is_categorical":true},"EFFECTIVEDATE":{"sql_type":"DATE","pl_type":"pl.Date()","mandatory":true,"comment":"Effective date of record","examples":["2026/09/08 00:00:00"],"parse_csv_as_string":true,"is_date":true},"VERSIONNO":{"sql_type":"NUMBER(22,0)","pl_type":"pl.UInt128","mandatory":true,"comment":"Version no of record for given effective date","examples":["1"],"is_integer":true,"unsigned_int":true,"num_int_bits":128},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Record creation timestamp","examples":["2026/09/04 15:07:18"],"parse_csv_as_string":true,"is_s_datetime":true},"REGIONID":{"sql_type":"VARCHAR2(10)","pl_type":"pl.Enum([\"QLD1\", \"VIC1\", \"TAS1\", \"NSW1\", \"SA1\", \"SNOWY1\"])","mandatory":false,"comment":"Region Identifier","examples":null,"enums":["QLD1","VIC1","TAS1","NSW1","SA1","SNOWY1"]},"SECONDARY_TLF":{"sql_type":"NUMBER(18,8)","pl_type":"pl.Float64","mandatory":false,"comment":"Used in Bidding, Dispatch and Settlements, only populated where Dual TLFs apply. For Bidding and Dispatch, the TLF for the generation component of a BDU, when null the TRANSMISSIONLOSSFACTOR is used for both the load and generation components. For Settlements, the secondary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is positive (net generation).","examples":["0.9817","0.9917"],"is_float":true},"TRANSMISSIONLOSSFACTOR":{"sql_type":"NUMBER(15,5)","pl_type":"pl.Float64","mandatory":true,"comment":"Used in Bidding, Dispatch and Settlements. For Bidding and Dispatch, where the DUID is a BDU with DISPATCHTYPE of BIDIRECTIONAL, the TLF for the load component of the BDU. For Settlements, where dual TLFs apply, the primary TLF is applied to all energy (load and generation) when the Net Energy Flow of the ConnectionPointID in the interval is negative (net load).","examples":["0.9862","1","1.0036"],"is_float":true,"col_name_also_metadata":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23TRANSMISSIONLOSSFACTOR%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2015,"month":1},"last_month":{"year":2026,"month":9},"has_missing_months":true,"compressed_size_per_month":536,"decompressed_size_all_time":1523700},"visibility":"Public","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns TRANSMISSIONLOSSFACTOR. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"},{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns TRANSMISSIONLOSSFACTOR. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"When new connection points are created or loss factors change"},"VALUATIONID":{"package":"IRAUCTION","pdr_config":{"mappings":[{"REPORT_NAME":"IRAUCTION","REPORT_SUB_TYPE":"VALUATIONID","VERSION":1}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.htm#250"],"comment":"VALUATIONID shows the identifiers and descriptions of the valuers submitting estimates of upcoming settlement residues. VALUATIONID supports the Settlement Residue Auction.","description":"VALUATIONID is public data, and is available to all participants.\n\nSource\n\nVALUATIONID updates are quarterly from the Settlement Residues\nInformation System \\[SRIS\\].\n\nVolume\n\nVALUATIONID shows up to five (5) records. Updates are rare.","primary_keys":["VALUATIONID"],"indexes":[["LASTCHANGED"]],"columns":{"VALUATIONID":{"sql_type":"VARCHAR2(15)","pl_type":"pl.Categorical","mandatory":true,"comment":"Identifier of the estimator","is_categorical":true,"col_name_also_metadata":true},"DESCRIPTION":{"sql_type":"VARCHAR2(80)","pl_type":"str","mandatory":false,"comment":"Full name of estimator"},"LASTCHANGED":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Timestamp of record creation or modification","examples":["2026/01/20 00:05:00"],"parse_csv_as_string":true,"is_s_datetime":true}},"visibility":"Public","warnings":[{"msg":"The REPORT_SUB_TYPE metadata column has the same column name as an actual columns VALUATIONID. So the raw CSVs have duplicate column names. You will need to be careful when reading this CSV.","category":"parsing"}],"trigger":"Updated quarterly"},"VOLTAGE_INSTRUCTION":{"package":"VOLTAGE_INSTRUCTIONS","pdr_config":{"mappings":[{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"INSTRUCTION","VERSION":1},{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"INSTRUCTION","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec75.htm#1"],"comment":"Child record for Voltage Instructions (MVAr Dispatch)","primary_keys":["EMS_ID","RUN_DATETIME","VERSION_DATETIME"],"indexes":[["RUN_DATETIME","VERSION_DATETIME","EMS_ID"]],"columns":{"EMS_ID":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Categorical","mandatory":true,"comment":"The unique identifier for reference within AEMO –matches equipment names between NOS and EMS","examples":["APD.REAC.A2REAC.VSWT","APD.REAC.A3REAC.VSWT","ARDN_W.CAP.CAP1.VSWT","ARMIDALE.CAP.C1.VSWT","ARMIDALE.CAP.C2.VSWT","ARMIDALE.CAP.C3.VSWT","ARMIDALE.CAP.C4.VSWT","ARMIDALE.CAP.C5.VSWT","ARMIDALE.CAP.C6.VSWT","ARMIDALE.REAC.R1.VSWT","ARMIDALE.REAC.R2.VSWT","ARMIDALE.REAC.R3.VSWT","ARMIDALE.REAC.R4.VSWT","ARMIDALE.SVC.1.VV_D","ARTS.BUS.7SYN.VV_D","ARWF.BUS.4MN1.VV_D","ATS.CAP.2CAP_2B_220.VSWT","BALRANLD.BUS.LX7.VV_D","BALRANLD.BUS.LX8.VV_D","BANGOWF.BUS.41.VV_D","BANGOWF.BUS.42.VV_D","BANNABY.REAC.R1.VSWT","BANNABY.REAC.R2.VSWT","BARK_I.TF.T_1.VT_D","BARK_I.TF.T_2.VT_D","BARK_I.TF.T_3.VT_D","BATS.CAP.1CAP_66.VSWT","BATS.CAP.2CAP_66.VSWT","BAYSWATR.REAC.R1.VSWT","BAYSWATR.REAC.R2.VSWT","BAYSWATR.TX.1A.VT_D","BAYSWATR.TX.1B.VT_D","BAYSWATR.TX.2A.VT_D","BAYSWATR.TX.2B.VT_D","BAYSWATR.TX.3A.VT_D","BAYSWATR.TX.3B.VT_D","BAYSWATR.TX.4A.VT_D","BAYSWATR.TX.4B.VT_D","BETS.CAP.2CAP_4XN_66.VSWT","BETS.CAP.3CAP_3B_66.VSWT","BFIELD_N.CAP.C1.VSWT","BFIELD_N.CAP.C2.VSWT","BFIELD_N.REAC.R2.VSWT","BFIELD_S.REAC.R1.VSWT","BGS.BUS.6T1.VV_D","BGTS.BUS.1B_220.VV_D","BLTS.CAP.4CAP_4B_220.VSWT","BLUFF_WF.GEN.PPR_1.VV_D","BLYBSS.BUS.HTDP.VV_D","BLYBSS.TF.T_1.VT_D","BRAE_PS.TRANS.1_H47.VT_D","BRAE_PS.TRANS.2_H47.VT_D","BRAE_PS.TRANS.3_H47.VT_D","BRKNHILL.REAC.R1.VSWT","BRKNHILL.REAC.R2.VSWT","BRKNILL.BUS.7.VV_D","BRYBNKWF.BUS.7MNA.VV_D","BRYBNKWF.BUS.7T3.VV_D","BTS.CAP.1ACAP_66.VSWT","BTS.CAP.1BCAP_66.VSWT","BTS.CAP.1CAP_22.VSWT","BTS.CAP.3ACAP_66.VSWT","BTS.CAP.3BCAP_66.VSWT","BTS.CAP.3CAP_22.VSWT","BUNDEY.CAP.C_1.VSWT","BUNDEY.REAC.REACT_BUR1.VSWT","BUNDEY.REAC.REACT_BUR2.VSWT","BUNDEY.REAC.REACT_EB.VSWT","BUNGAM_B.BUS.8MN1.VV_D","BUNGAM_B.CAP.CAP_41.VSWT","BUNGAM_B.REAC.REACT_51.VSWT","BURNIE.CAP.C1.VSWT","BURONGA.REAC.R2.VSWT","BURONGA.REAC.R3.VSWT","CAL_B_PS.TRANS.1_GEN_H30.VT_D","CAL_B_PS.TRANS.2_GEN_H30.VT_D","CAL_C_PS.TRANS.3_GEN_H50.VT_D","CAL_C_PS.TRANS.4_GEN_H50.VT_D","CANBERRA.CAP.C1.VSWT","CANBERRA.CAP.C2.VSWT","CANBERRA.CAP.C3.VSWT","CANBERRA.CAP.C4.VSWT","CAPITAL.BUS.5C.VV_D","CAPITAL.BUS.5XF3.VV_D","CBTS.TRANS.A1TR_220.VT_D","CHAPEL.BUS.220KV_BUS_A.VV_D","CHAPEL.CAP.C1.VSWT","CHAPEL.CAP.C2.VSWT","CH_GDN.CAP.C_61.VSWT","CH_GDN.REAC.CH_REAC.VSWT","CITY_W.REAC.R1.VSWT","CITY_W.REAC.R2.VSWT","COLLECWF.BUS.5A.VV_D","COLONGRA.TX.GEN1.VT_D","COLONGRA.TX.GEN2.VT_D","COLONGRA.TX.GEN3.VT_D","COLONGRA.TX.GEN4.VT_D","COOR_2.BUS.4XF1.VV_D","COOR_S.BUS.4MN1.VV_D","CPTS.BUS.LCPS.VV_D","CROOKWF.BUS.5A.VV_D","CROOKWF.BUS.5B.VV_D","CRUDNEWF.BUS.41.VV_D","CULC_SF.BUS.5A.VV_D","CWWF.BUS.7T1.VV_D","DAPTO.CAP.C1.VSWT","DAPTO.CAP.C2.VSWT","DARL_PT.BUS.4A.VV_D","DARL_PT.BUS.5B.VV_D","DARL_PT.CAP.C1.VSWT","DARL_PT.CAP.C2.VSWT","DARL_PT.CAP.C3.VSWT","DAVENP.REAC.R2.VSWT","DAVENP.REAC.R3.VSWT","DAVENP.REAC.R4.VSWT","DAVENP.REAC.R5.VSWT","DDTS.CAP.1CAP_220.VSWT","DDTS.CAP.1CAP_330.VSWT","DDTS.CAP.2CAP_330.VSWT","DEERPARK.CAP.4CAPA_66.VSWT","DEERPARK.CAP.4CAPB_66.VSWT","DPS.GEN.GEN.VV_D","DRY_CK.TF.T_1S.VT_D","DRY_CK.TF.T_2S.VT_D","DRY_CK.TF.T_3S.VT_D","DUMARESQ.CAP.C1.VSWT","DUMARESQ.CAP.C2.VSWT","DUMARESQ.REAC.R1.VSWT","DUMARESQ.REAC.R2.VSWT","DUMARESQ.REAC.R3.VSWT","DUMARESQ.REAC.R4.VSWT","DUMARESQ.SVC.1.VV_D","ELTS.BUS.7TR3.VV_D","ELTS.BUS.7TW1.VV_D","EMEROO.BUS.4MN1.VV_D","EPS.GEN.1GEN.VV_D","EPS.GEN.2GEN.VV_D","ERARING.REAC.R2.VSWT","ERARING.TX.1A.VT_D","ERARING.TX.1B.VT_D","ERARING.TX.2A.VT_D","ERARING.TX.2B.VT_D","ERARING.TX.3A.VT_D","ERARING.TX.3B.VT_D","ERARING.TX.4A.VT_D","ERARING.TX.4B.VT_D","ERA_BESS.BUS.5A.VV_D","ERTS.CAP.1BCAP_1B_66.VSWT","ERTS.CAP.1CAP_1B_66.VSWT","ERTS.CAP.3CAP_3B_66.VSWT","ERTS.CAP.4CAP_4B_66.VSWT","FAKE.EMS.1.VSWT","FAKE.EMS.2.VSWT","FARRELL.BUS.220KV_BUS_A.VV_D","FBTS.CAP.4CAP.VSWT","GETS.BUS.7MN1.VV_D","GLDFORD.BUS.2MN3.VV_D","GNTS.BUS.3MN1.VV_D","GNTS.BUS.7MN1.VV_D","GNTS.CAP.1CAP.VSWT","GRWF.BUS.5C.VV_D","GTS.CAP.CAP_1B_66.VSWT","GTS.CAP.CAP_4B_66.VSWT","GUNDH_SF.BUS.41.VV_D","GWSF.BUS.3T1.VV_D","GYDR_WF.BUS.8XF1.VV_D","GYDR_WF.BUS.8XF2.VV_D","G_TOWN.CAP.C1.VSWT","G_TOWN.CAP.C2.VSWT","G_TOWN.CAP.C3.VSWT","H108_TUM.BUS.8945.VV_D","H10_BCMB.BUS.4MN1.VV_D","H110_BSD.BUS.8MN1.VV_D","H110_BSD.BUS.BGEN.VV_D","H113_ALD.BUS.8MN1.VV_D","H114_WB2.BUS.8MN2.VV_D","H11_NEBO.CAP.2_BANK_H11.VSWT","H11_NEBO.CAP.3_BANK_H11.VSWT","H11_NEBO.REAC.1BUS_REAC_H11.VSWT","H11_NEBO.REAC.821_H11.VSWT","H11_NEBO.REAC.8847_H11.VSWT","H11_NEBO.SVC.1_H11.VV_D","H121_WDB.BUS.DRP1.VV_D","H121_WDB.BUS.DRP2.VV_D","H12_MT_E.CAP.1_BANK_H12.VSWT","H12_MT_E.CAP.2_BANK_H12.VSWT","H138_TRB.BUS.8MN1.VV_D","H13_ROSS.CAP.1_BANK_H13.VSWT","H13_ROSS.REAC.1BUS_REAC_H13.VSWT","H13_ROSS.REAC.2BUS_REAC_H13.VSWT","H13_ROSS.REAC.8857_H13.VSWT","H13_ROSS.REAC.8858_H13.VSWT","H13_ROSS.SVC.1_H13.VV_D","H14_MRDG.CAP.1_BANK_H14.VSWT","H14_MRDG.CAP.2_BANK_H14.VSWT","H14_MRDG.CAP.3_BANK_H14.VSWT","H14_MRDG.CAP.4_BANK_H14.VSWT","H154_SNB.BUS.8MN1.VV_D","H154_SNB.BUS.8MN2.VV_D","H157_ULB.BUS.DRP.VV_D","H15_LILY.CAP.1_BANK_H15.VSWT","H162_BNB.BUS.8MN1.VV_D","H16_RLEA.CAP.1_BANK_H16.VSWT","H16_RLEA.CAP.2_BANK_H16.VSWT","H16_RLEA.CAP.3_BANK_H16.VSWT","H182_SBK.BUS.8MN1.VV_D","H18_TRNG.CAP.1_BANK_H18.VSWT","H20_BSND.BUS.1.VV_D","H20_BSND.REAC.1_H20.VSWT","H20_BSND.REAC.820_H20.VSWT","H20_BSND.REAC.856_H20.VSWT","H21_MRRE.CAP.2_BANK_H21.VSWT","H21_MRRE.CAP.3_BANK_H21.VSWT","H22_LOGN.CAP.4_BANK_H22.VSWT","H22_LOGN.CAP.5_BANK_H22.VSWT","H22_LOGN.CAP.6_BANK_H22.VSWT","H22_LOGN.CAP.7_BANK_H22.VSWT","H24_CALV.REAC.8810_H24.VSWT","H24_CALV.REAC.8811_H24.VSWT","H29_STAN.BUS.275KV_1_H29.VV_D","H2_SPINE.CAP.11_BANK_H2.VSWT","H2_SPINE.CAP.12_BANK_H2.VSWT","H2_SPINE.CAP.3_BANK_H2.VSWT","H2_SPINE.CAP.4_BANK_H2.VSWT","H2_SPINE.CAP.6_BANK_H2.VSWT","H2_SPINE.CAP.7_BANK_H2.VSWT","H2_SPINE.CAP.8_BANK_H2.VSWT","H2_SPINE.CAP.9_BANK_H2.VSWT","H2_SPINE.SVC.10_H2.VV_D","H31_MDNR.CAP.3_BANK_H31.VSWT","H31_MDNR.CAP.4_BANK_H31.VSWT","H32_CHLM.REAC.1_TFMR_H32.VSWT","H32_CHLM.REAC.5_REAC_H32.VSWT","H32_CHLM.REAC.857_H32.VSWT","H32_CHLM.REAC.858_H32.VSWT","H35_STHM.REAC.1_REAC_H35.VSWT","H35_STHM.SVC.1_H35.VV_D","H36_BLKW.CAP.5_BANK_H36.VSWT","H36_BLKW.CAP.6_BANK_H36.VSWT","H36_BLKW.SVC.1_H36.VV_D","H38_GDNA.CAP.3_BANK_H38.VSWT","H39_WORE.CAP.1_BANK_H39.VSWT","H39_WORE.CAP.2_BANK_H39.VSWT","H39_WORE.REAC.REAC_877.VSWT","H39_WORE.REAC.REAC_8902.VSWT","H39_WORE.REAC.REAC_8905.VSWT","H39_WORE.SVC.3_H39.VV_D","H39_WORE.TRANS.1_H39.VT_D","H39_WORE.TRANS.2_H39.VT_D","H3_BELMT.CAP.10_BANK_H3.VSWT","H3_BELMT.CAP.3_BANK_H3.VSWT","H3_BELMT.CAP.4_BANK_H3.VSWT","H3_BELMT.CAP.6_BANK_H3.VSWT","H3_BELMT.CAP.7_BANK_H3.VSWT","H3_BELMT.CAP.8_BANK_H3.VSWT","H3_BELMT.CAP.9_BANK_H3.VSWT","H3_BELMT.REAC.2_H3.VSWT","H40_WURD.CAP.1_BANK_H40.VSWT","H40_WURD.CAP.2_BANK_H40.VSWT","H40_WURD.CAP.3_BANK_H40.VSWT","H48_B2PS.TRANS.1_H48.VT_D","H48_B2PS.TRANS.2_H48.VT_D","H48_B2PS.TRANS.3_H48.VT_D","H4_MUGBA.CAP.2_BANK_H4.VSWT","H4_MUGBA.CAP.4_BANK_H4.VSWT","H5_WLGA.BUS.4MN1.VV_D","H5_WLGA.CAP.1_BANK_H5.VSWT","H5_WLGA.CAP.2_BANK_H5.VSWT","H5_WLGA.CAP.3_BANK_H5.VSWT","H5_WLGA.SVC.4_H5.VV_D","H60_WALK.BUS.8MN1.VV_D","H67_CALR.TRANS.1_H67.VT_D","H67_CALR.TRANS.2_H67.VT_D","H6_GNGN.CAP.2_BANK_H6.VSWT","H71_DDPS.TRANS.1_H71.VT_D","H71_DDPS.TRANS.2_H71.VT_D","H71_DDPS.TRANS.3_H71.VT_D","H71_DDPS.TRANS.4_H71.VT_D","H76_WAND.BUS.4MN1.VV_D","H76_WAND.BUS.4MN2.VV_D","H76_WAND.BUS.8963.VV_D","H78_ORAN.BUS.8MN1.VV_D","H7_GLAD.TRANS.1_GEN_H7.VT_D","H7_GLAD.TRANS.2_GEN_H7.VT_D","H7_GLAD.TRANS.5_GEN_H7.VT_D","H7_GLAD.TRANS.6_GEN_H7.VT_D","H85_COOP.BUS.8MN1.VV_D","H86_DDSF.BUS.8B1.VV_D","H87_CRCK.TRANS.1_H87.VT_D","H91_HGTN.BUS.8MN2.VV_D","H93_GUMN.REAC.RTC1.VSWT","H98_WBWF.BUS.8MN1.VV_D","H9_PLMWD.CAP.1_BANK_H9.VSWT","H9_PLMWD.CAP.2_BANK_H9.VSWT","H9_PLMWD.CAP.3_BANK_H9.VSWT","H9_PLMWD.CAP.4_BANK_H9.VSWT","H9_PLMWD.CAP.5_BANK_H9.VSWT","HALHIL.GEN.HLH_1.VQ_D","HAL_WF.GEN.HAL1.VQ_D","HAYMARKT.REAC.R1.VSWT","HDWF.BUS.TRTS_6T2.VV_D","HGTS.BUS.6T1.VV_D","HOTS.CAP.1ACAP_66.VSWT","HOTS.CAP.1BCAP_66.VSWT","HOTS.CAP.2CAP_2B_66.VSWT","HOTS.REAC.1REAC_1B_66.VSWT","HOTS.REAC.2REAC_2B_66.VSWT","HOTS.SVC.SVC.VV_D","HTS.CAP.1BCAP_66.VSWT","HTS.CAP.1CAP_66.VSWT","HUMMOC.CAP.C_2.VSWT","HWBS.BUS.7T1.VV_D","HYTS.CAP.1CAP_275.VSWT","HYTS.TRANS.M1TR_500.VT_D","HYTS.TRANS.M2TR_500.VT_D","HYTS.TRANS.M3TR.VT_D","H_VALL.CAP.C_62.VSWT","JINDERA.BUS.5XF1.VV_D","JLGSA.TRANS.A1_TR.VT_D","JLGSA.TRANS.A2_TR.VT_D","JLGSA.TRANS.A3_TR.VT_D","JLGSA.TRANS.A4_TR.VT_D","JLGSB.TRANS.B1_TR.VT_D","JLGSB.TRANS.B2_TR.VT_D","JLGSB.TRANS.B3_TR.VT_D","KANGAROO.BUS.5B3.VV_D","KAR_H_PS.TRANS.1_T49_ZH.VT_D","KAR_H_PS.TRANS.2_T49_ZH.VT_D","KEMPS_CK.CAP.C1.VSWT","KEMPS_CK.CAP.C2.VSWT","KEMPS_CK.REAC.R2.VSWT","KEMPS_CK.REAC.R3.VSWT","KEMPS_CK.REAC.R5.VSWT","KEMPS_CK.REAC.R6.VSWT","KEMPS_CK.REAC.RS.VSWT","KGTS.CAP.1CAP_66.VSWT","KGTS.CAP.2CAP_22.VSWT","KGTS.CAP.2CAP_66.VSWT","KGTS.REAC.REAC_66.VSWT","KGTS.SVC.SVC.VV_D","KIAMALSF.BUS.7MN2.VV_D","KINCRA.CAP.CAP1.VSWT","KING.BUS.BUS1.VV_D","KOGAN_PS.TRANS.1_H52.VT_D","KOTS.BUS.LKRE.VV_D","KTS.CAP.1ACAP_1B_66.VSWT","KTS.CAP.1BCAP_66.VSWT","KTS.CAP.1CAP_1B_220.VSWT","KTS.REAC.REAC_1B_220.VSWT","KTS.REAC.REAC_2B_220.VSWT","KTS.TRANS.A2TR.VT_D","KTS.TRANS.A3TR.VT_D","KTS.TRANS.A4TR.VT_D","LADB_G.TF.T_1S.VT_D","LADB_G.TF.T_2S.VT_D","LIAPOOTA.BUS.220KV_BUS_A.VV_D","LIDDELL.BUS.5GN.VV_D","LIDDELL.TX.1H.VT_D","LIDDELL.TX.2H.VT_D","LIDDELL.TX.3H.VT_D","LIDDELL.TX.4H.VT_D","LINFARNE.CAP.C1.VSWT","LIN_GP.BUS.BUS.VV_D","LISMORE.CAP.C1.VSWT","LISMORE.CAP.C2.VSWT","LISMORE.REAC.R1.VSWT","LISMORE.REAC.R3.VSWT","LISMORE.SVC.1.VV_D","LY.CAP.1CAP.VSWT","LY.CAP.2CAP.VSWT","LYPA.TRANS.A1GTR.VT_D","LYPA.TRANS.A2GTR.VT_D","LYPA.TRANS.A3GTR.VT_D","LYPA.TRANS.A4GTR.VT_D","LYPB.TRANS.B1GTR.VT_D","LYPB.TRANS.B2GTR.VT_D","MANN_R.BUS.LMAN.VV_D","MASONPRK.REAC.R1.VSWT","MASONPRK.REAC.R2.VSWT","MAYURA.GEN.LAKE_BONY1.VQ_D","MAYURA.GEN.LAKE_BONY2A.VQ_D","MAYURA.GEN.LAKE_BONY2B.VQ_D","MAYURA.GEN.LAKE_BONY3.VQ_D","METZ_SF.BUS.41.VV_D","MEWF.CAP.CAP1.VSWT","MEWF.CAP.CAP2.VSWT","MILLM_PS.TRANS.1_R5.VT_D","MILLM_PS.TRANS.2_R5.VT_D","MKPS.BUS.1B_11.VV_D","MKPS.BUS.2B_11.VV_D","MKPS.BUS.3B_11.VV_D","MKPS.GEN.BOPS_G1.VV_D","MKPS.GEN.BOPS_G2.VV_D","MLNK_B.BUS.4T32.VV_D","MLRC.BUS.7T1.VV_D","MLSW.BUS.7TX1.VV_D","MLTS.CAP.1CAP_1B_220.VSWT","MLTS.CAP.2CAP_2B_220.VSWT","MLTS.REAC.2REAC_2B_220.VSWT","MLTS.REAC.3REAC_2B_220.VSWT","MLTS.REAC.REAC_1B_220.VSWT","MLTS.TRANS.A1TR_220.VT_D","MLTS.TRANS.A2TR_220.VT_D","MNM_BESS.BUS.HTDP.VV_D","MNM_BESS.GEN.MANNUM_B_GEN.VQ_D","MONASH.CAP.C_61.VSWT","MONASH.CAP.C_62.VSWT","MOPS.BUS.LMPE.VV_D","MOPS.TRANS.GEN11_TR_500KV.VT_D","MOPS.TRANS.GEN12_TR_500KV.VT_D","MOUR_SF.GEN.MOURSF1.VV_D","MRTS.BUS.T1_220.VV_D","MRTS.BUS.T2_220.VV_D","MT_LOC.BUS.LHNW.VV_D","MT_PIPER.REAC.R1.VSWT","MT_PIPER.REAC.R2.VSWT","MT_PIPER.TX.1H.VT_D","MT_PIPER.TX.2H.VT_D","MT_S_PS.TRANS.1_GEN_MT_S.VT_D","MT_S_PS.TRANS.2_GEN_MT_S.VT_D","MT_S_PS.TRANS.3_GEN_MT_S.VT_D","MUNMORAH.BUS.5MN.VV_D","MURRAY.BUS.5A1.VV_D","MURRAY.REAC.R1.VSWT","MURRAY.REAC.R2.VSWT","MURRAY.REAC.R3.VSWT","MURRAY.UNIT.11.VCMT","MURRAY.UNIT.12.VCMT","MURRAY.UNIT.13.VCMT","MURRAY.UNIT.14.VCMT","MUSBK330.CAP.C1.VSWT","MWF.CAP.CAP2.VSWT","MWF.CAP.CAP5.VSWT","MWTS.BUS.3MN2.VV_D","NARRAND.BUS.41.VV_D","NEWCSTLE.CAP.C1.VSWT","NEWCSTLE.CAP.C2.VSWT","NEWCSTLE.CAP.C3.VSWT","NEWCSTLE.CAP.C4.VSWT","NO_B_H.GEN.NBH_A.VQ_D","NO_B_H.GEN.NBH_B.VQ_D","NPSD.TRANS.GTR.VT_D","N_NRFOLK.BUS.4MNA.VV_D","N_NRFOLK.CAP.C1.VSWT","OAKEY_PS.TRANS.1_GE_OAK.VT_D","OAKEY_PS.TRANS.2_GE_OAK.VT_D","OCPL.TF.T_MT1.VT_D","OCPL.TF.T_MT2.VT_D","PALMSTN.BUS.220KV_BUS_A.VV_D","PARA.CAP.C_61.VSWT","PARA.CAP.C_62.VSWT","PARA.REAC.PAR_EBL_REAC.VSWT","PARA.REAC.PAR_R_BWL.VSWT","PARA.SVC.SVC1.VV_D","PARA.SVC.SVC2.VV_D","PEL_PS.TF.T_11BA10.VT_D","PEL_PS.TF.T_12BA10.VT_D","PEL_PS.TF.T_18BA10.VT_D","PLTS.BUS.LPLE.VV_D","PRTS.BUS.LMR1.VV_D","PRTS.BUS.LMR2.VV_D","PRTS.BUS.LMR3.VV_D","PT_L_T.TF.SUT_3.VT_D","PT_L_T.TF.T_P.VT_D","P_PA_N.BUS.8B1.VV_D","QPS.TF.T_GTA1_2.VT_D","QPS.TF.T_GTA3_4.VT_D","QPS.TF.T_GTA5.VT_D","QRNPRK.BUS.LQSF.VV_D","QUEANBYN.BUS.42.VV_D","R15_MISS.BUS.5MN1.VV_D","R2_BRAE.CAP.2_BANK_R2.VSWT","R3_BULLI.REAC.8L_REACT.VSWT","R3_BULLI.REAC.8M_REACT.VSWT","R3_BULLI.REAC.9901_R3.VSWT","R3_BULLI.REAC.9902_R3.VSWT","R4_MILLM.CAP.1_BANK_R4.VSWT","RBES.BUS.7T1.VV_D","RCTS.CAP.1CAP_1B_22.VSWT","RCTS.CAP.1CAP_1B_66.VSWT","RCTS.CAP.1CAP_220.VSWT","RCTS.CAP.2CAP_220.VSWT","RCTS.CAP.2CAP_2B_22.VSWT","RCTS.CAP.2CAP_2B_66.VSWT","RCTS.REAC.1REAC_1B_66.VSWT","RCTS.REAC.2REAC_2B_66.VSWT","RCTS.REAC.3REAC_2B_66.VSWT","RCWF.BUS.TRTS_6T2K.VV_D","REGENTVL.CAP.C1.VSWT","REGENTVL.CAP.C2.VSWT","RISDON.CAP.C1.VSWT","RISDON.CAP.C2.VSWT","RISDON.CAP.C3.VSWT","RISDON.CAP.C4.VSWT","ROOKWOOD.REAC.R4.VSWT","ROOKWOOD.REAC.R5.VSWT","ROTS.CAP.1CAP_1B.VSWT","ROTS.CAP.2CAP_2B.VSWT","ROTS.CAP.3CAP_3B.VSWT","ROTS.CSC.1CSC.VV_D","ROTS.CSC.2CSC.VV_D","ROTS_500.TRANS.A1TR_220.VT_D","ROTS_500.TRANS.A2TR_500.VT_D","RTS.CAP.1CAP_1B_66.VSWT","RTS.CAP.4CAP_4B_66.VSWT","RWTS.CAP.2BCAP_2B_66.VSWT","RWTS.CAP.2CAP_2B_220.VSWT","RWTS.CAP.2CAP_2B_66.VSWT","RYE_P_WF.BUS.5S1.VV_D","R_TOWN.TF.T_1.VT_D","R_TOWN.TF.T_2.VT_D","S3_GNBNK.BUS.TDRP.VV_D","S3_GNBNK.CAP.3_BANK_S3.VSWT","S3_GNBNK.CAP.4_BANK_S3.VSWT","S3_GNBNK.CAP.5_BANK_S3.VSWT","S3_GNBNK.CAP.6_BANK_S3.VSWT","S3_GNBNK.SVC.1_S3.VV_D","S5_WESTD.BUS.2.VV_D","SAPWF.BUS.53.VV_D","SBK_E_PS.TRANS.1_GEN_H55.VT_D","SHEFIELD.BUS.220KV_BUS_A.VV_D","SHEFIELD.CAP.C1.VSWT","SHTS.CAP.2ACAP_66.VSWT","SHTS.CAP.2BCAP_66.VSWT","SHTS.CAP.3ACAP_66.VSWT","SHTS.CAP.3BCAP_66.VSWT","SMTS.TRANS.F1TR.VT_D","SMTS.TRANS.F2TR_330.VT_D","SMTS.TRANS.H1TR.VT_D","SMTS.TRANS.H2TR.VT_D","SMTS.TRANS.H3TR.VT_D","SNAP_P.BUS.HTFB.VV_D","SNUGGY.TF.T_1S.VT_D","SNUGGY.TF.T_2S.VT_D","SNUGGY.TF.T_3S.VT_D","STS_WF.BUS.8MN1.VV_D","STUBO_SF.BUS.5A.VV_D","STUBO_SF.BUS.5B.VV_D","SVTS.CAP.1CAP_66.VSWT","SVTS.CAP.4BCAP_66.VSWT","SVTS.CAP.4CAP_66.VSWT","SYD_EAST.CAP.C1.VSWT","SYD_EAST.CAP.C2.VSWT","SYD_EAST.CAP.C3.VSWT","SYD_EAST.CAP.C4.VSWT","SYD_EAST.REAC.R1.VSWT","SYD_NTH.CAP.C3.VSWT","SYD_NTH.CAP.C4.VSWT","SYD_NTH.CAP.C5.VSWT","SYD_STH.CAP.C1.VSWT","SYD_STH.CAP.C2.VSWT","SYD_STH.CAP.C3.VSWT","SYD_STH.REAC.R1.VSWT","SYD_STH.REAC.R2.VSWT","SYD_STH.REAC.R3.VSWT","SYD_WEST.CAP.C1.VSWT","SYD_WEST.CAP.C2.VSWT","SYD_WEST.CAP.C3.VSWT","SYD_WEST.CAP.C5.VSWT","SYD_WEST.CAP.C6.VSWT","SYD_WEST.CAP.C7.VSWT","SYD_WEST.SVC.1.VV_D","S_EAST.CAP.C_61.VSWT","S_EAST.CAP.C_62.VSWT","S_EAST.REAC.S_E_REACTOR.VSWT","S_EAST.SVC.SVC1.VV_D","S_EAST.SVC.SVC2.VV_D","T129_EDM.CAP.2_BANK_T129.VSWT","T136_ABM.CAP.2_BANK_T136.VSWT","T140_TZC.BUS.2MN1.VV_D","T141_PVA.CAP.1_BANK_T141.VSWT","T152_G_S.CAP.1_BANK_T152.VSWT","T152_G_S.CAP.5_BANK_T152.VSWT","T155_WDR.CAP.1_BANK_T155.VSWT","T155_WDR.CAP.2_BANK_T155.VSWT","T155_WDR.CAP.3_BANK_T155.VSWT","T161_ALG.CAP.1_BANK_T161.VSWT","T193_CLS.CAP.1_BANK_T193.VSWT","T194_CLB.BUS.4MN1.VV_D","T194_CLB.BUS.4MN2.VV_D","T200CMPS.TRANS.1_T200.VT_D","T200CMPS.TRANS.2_T200.VT_D","T217_CBC.CAP.1_BANK_T217.VSWT","T217_CBC.CAP.2_BANK_T217.VSWT","T220_COL.CAP.1_BANK_T220.VSWT","T241_LKR.BUS.4T1.VV_D","T243_YRN.BUS.4MN1.VV_D","T255_RRS.BUS.4TX1.VV_D","T271_WSB.GEN.WANDBG.VQ_D","T27_MRA.CAP.1_BANK_T27.VSWT","T287_DWF.BUS.4MN1.VV_D","T294_BDL.BUS.4MN1.VV_D","T296_GON.BUS.3.VV_D","T30_ASHW.CAP.2_BANK_T30.VSWT","T30_ASHW.CAP.3_BANK_T30.VSWT","T30_ASHW.CAP.4_BANK_T30.VSWT","T32_BWTR.CAP.2_BANK_T32.VSWT","T35_DYST.CAP.2_BANK_T35.VSWT","T35_DYST.CAP.3_BANK_T35.VSWT","T50_INFL.CAP.1_BANK_T50.VSWT","T55_TURK.CAP.1_BANK_T55.VSWT","T56_TV_S.CAP.3_BANK_T56.VSWT","T56_TV_S.CAP.4_BANK_T56.VSWT","T5_GLAD.TRANS.3_GEN_T5.VT_D","T5_GLAD.TRANS.4_GEN_T5.VT_D","T65_ALCK.CAP.1_BANK_T65.VSWT","T67_KMIS.CAP.1_BANK_T67.VSWT","T69_NLDS.CAP.1_BANK_T69.VSWT","T83_ROMA.TRANS.7_GEN_ROMA.VT_D","T83_ROMA.TRANS.8_GEN_ROMA.VT_D","T94K_TEE.BUS.T94K.VV_D","TALAWARA.CAP.C1.VSWT","TALAWARA.TX.1H.VT_D","TAMWORTH.CAP.C1.VSWT","TAMWORTH.CAP.C3.VSWT","TAMWORTH.CAP.C4.VSWT","TAMWORTH.REAC.R1.VSWT","TAMWORTH.REAC.R2.VSWT","TAMWORTH.SVC.1.VV_D","TBTS.BUS.LMNE.VV_D","TBTS.CAP.1CAP_66.VSWT","TEMP_W.REAC.R1.VSWT","TGTS.BUS.LTGE.VV_D","TGTS.CAP.CAP.VSWT","TIPS_A.TF.T_1S.VT_D","TIPS_A.TF.T_2S.VT_D","TIPS_A.TF.T_3S.VT_D","TIPS_A.TF.T_4S.VT_D","TIPS_B.TF.T_1S.VT_D","TIPS_B.TF.T_2S.VT_D","TIPS_B.TF.T_3S.VT_D","TIPS_B.TF.T_4S.VT_D","TI_BESS.BUS.HTF1.VV_D","TOMAGO.CAP.C1.VSWT","TP_BESS.BUS.HTDP.VV_D","TP_BESS.CAP.HF1.VSWT","TP_BESS.GEN.TEMPLE_B_GEN.VQ_D","TRNGN_PS.TRANS.1_GEN_H54.VT_D","TRNG_PS.TRANS.1_GEN_H27.VT_D","TRNG_PS.TRANS.2_GEN_H27.VT_D","TRNG_PS.TRANS.3_GEN_H27.VT_D","TRNG_PS.TRANS.4_GEN_H27.VT_D","TRTS.BUS.6T1.VV_D","TSTS.CAP.1CAP_1B_220.VSWT","TSTS.CAP.1CAP_66.VSWT","TTS.CAP.1CAP_1B_220.VSWT","TTS.CAP.2CAP_2B_66.VSWT","TTS.CAP.3CAP_3B_220.VSWT","TTS.CAP.4BCAP_66.VSWT","TTS.CAP.4CAP_4B_66.VSWT","TUGGERAH.CAP.C1.VSWT","TUGGERAH.CAP.C2.VSWT","TUMUT1_2.BUS.5A1.VV_D","TUMUT1_2.UNIT.1.VCMT","TUMUT1_2.UNIT.2.VCMT","TUMUT1_2.UNIT.3.VCMT","TUMUT1_2.UNIT.4.VCMT","TUMUT3.BUS.5A1.VV_D","TUMUT3.UNIT.1.VCMT","TUMUT3.UNIT.2.VCMT","TUMUT3.UNIT.3.VCMT","TUMUT3.UNIT.4.VCMT","TUMUT3.UNIT.5.VCMT","TUMUT3.UNIT.6.VCMT","TUNKIL.CAP.CAP2.VSWT","TVLLE_PS.TRANS.1_GEN_TVL.VT_D","T_BEND.CAP.C_64.VSWT","URALLA.BUS.541.VV_D","URALLA.BUS.542.VV_D","URANQNTY.TX.UNIT11.VT_D","URANQNTY.TX.UNIT12.VT_D","URANQNTY.TX.UNIT13.VT_D","URANQNTY.TX.UNIT14.VT_D","VALES_PT.CAP.C1.VSWT","VALES_PT.CAP.C2.VSWT","VALES_PT.TX.5A.VT_D","VALES_PT.TX.5B.VT_D","VALES_PT.TX.6A.VT_D","VALES_PT.TX.6B.VT_D","VBB.BUS.220B.VV_D","VINEYARD.CAP.C1.VSWT","WAGGA330.CAP.C1.VSWT","WAGGA330.CAP.C2.VSWT","WAGGA330.CAP.C3.VSWT","WAGGA330.CAP.C4.VSWT","WALA_SF.BUS.5A.VV_D","WALA_SF.BUS.5B.VV_D","WATT_P.GEN.WP_1.VQ_D","WAT_WF.GEN.WW_C1.VQ_D","WAT_WF.GEN.WW_C2.VQ_D","WBTS.BUS.7MN1.VV_D","WELLNGTN.BUS.52.VV_D","WELLNGTN.BUS.L7Y.VV_D","WELLNGTN.CAP.C1.VSWT","WELLNGTN.CAP.C3.VSWT","WELLNGTN.REAC.R1.VSWT","WELLNGTN.REAC.R2.VSWT","WEL_N_SF.BUS.CA03.VV_D","WILLOG.BUS.8XF1.VV_D","WISF.BUS.3T1.VV_D","WIV_PS.TRANS.1_GEN_H28.VT_D","WIV_PS.TRANS.2_GEN_H28.VT_D","WKPS.BUS.1B_11.VV_D","WKPS.BUS.2B_11.VV_D","WMTS.CAP.2CAP_2B_66.VSWT","WMTS.CAP.3CAP_3B_66.VSWT","WOLLAR_W.BUS.5A.VV_D","WOTS.CAP.2CAP_330.VSWT","YASS.CAP.C1.VSWT","YASS.REAC.R1.VSWT","YASS.REAC.R2.VSWT","YASS.REAC.R3.VSWT","YDW.BUS.66KV.VV_D","YPS.TRANS.1GTR.VT_D","YPS.TRANS.2GTR.VT_D","YPS.TRANS.3GTR.VT_D","YPS.TRANS.4GTR.VT_D"],"is_categorical":true},"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"MVAr Interval – a timestamp of when instructions issued","examples":["2026/09/01 00:15:45"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime the file was published by VDS - Versions differ from Run_DateTime only for Supplemental runs","examples":["2026/09/01 00:15:45"],"parse_csv_as_string":true,"is_s_datetime":true},"ADDITIONAL_NOTES":{"sql_type":"VARCHAR2(60)","pl_type":"str","mandatory":false,"comment":"Additional information pertaining to a particular instruction, e.g. Previously issued instruction revoked","examples":["1_Primary"]},"CONFORMING":{"sql_type":"NUMBER(1,0)","pl_type":"pl.Int8","mandatory":false,"comment":"[0,1] Denotes if the Device is currently conforming","examples":["1"],"is_integer":true,"num_int_bits":8},"CONTROL_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"VOLTAGE\", \"TAP\", \"MVAR\", \"SWITCH\", \"COMMIT\"])","mandatory":false,"comment":"One of VOLTAGE, TAP, MVAR, SWITCH or COMMIT but may be extended to other types","examples":null,"enums":["VOLTAGE","TAP","MVAR","SWITCH","COMMIT"]},"DEVICE_ID":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Categorical","mandatory":false,"comment":"The company/participant preferred name of an equipment","examples":["1","1 BUS 5 REACTOR","8945","1 BUS REACTOR 275KV","1 BUS REACTOR 275KV H35 STRATHMORE","1 Bus","1 Bus Reactor (84Mvar/275kV)","1 CAPACITOR (140MVAR/300KV)","1 CAPACITOR (20MVAR/132KV)","1 CAPACITOR (30 MVAR/132KV)","1 CAPACITOR (40MVAR/132KV)","1 CAPACITOR - 50MVAR/110KV","1 CAPACITOR 132KV","1 CAPACITOR 200MVA/275KV","1 CAPACITOR 200MVAR/330KV","1 CAPACITOR 20MVAR/132KV","1 CAPACITOR 26 MVAR/132KV","1 CAPACITOR 275KV","1 Capacitor","1 Capacitor T152","1 Gen Tfmr H27","1 Gen Tfmr H28","1 Gen Tfmr H30","1 Gen Tfmr H7","1 Gen Tfmr Mt S","1 Gen Tfmr tvl","1 Gen Transfmr H47","1 Stat Comp H11","1 Stat Comp H13","1 Stat Comp H35","1 Stat Comp H36","1 TRANSFORMER (275/33KV - 250MVA)","1 TRANSFORMER (288/138/19.1KV - 375MVA)","1 Transf t49","1 Transformer","1 Transformer Reactor","1 Transformer tpi","1 Xfmr 132/11/11kV T200","10 CAPACITOR 120MVAR/275KV","10 STATIC COMPENSATOR -100MVAR TO +350MVAR","11 CAPACITOR 50MVAR/110KV","11 STATIC COMPENSATOR -100 TO +350MVAR","11.5/132 KV TF 1","11.5/132 KV TF 2","11.5/132 KV TF 3","11.5/66 KV TF MT-1","11.5/66 KV TF MT-2","11/66 KV TF 1","11/66 KV TF 2","11/66 KV TF 3","110KV 1 CAPACITOR","110KV 2 CAPACITOR","110KV 3 CAPACITOR","110KV 4 CAPACITOR","110KV 5 CAPACITOR","110kV 1 Capacitor","110kV 1 Gen Transformer","110kV 1 Xfmr T243","110kV 2 Capacitor","110kV 2 Gen Transformer","110kV POC ND 4MN1","12 CAPACITOR 50MVAR/110KV","13.8/275 KV TF GEN1","13.8/275 KV TF GEN2","13.8/275 KV TF GEN3","13.8/275 KV TF GEN4","132 KV 3 CAPACITOR","132/11 KV TF 1","132/11 KV TF 2","132KV 1 BUS","132KV 1 CAPACITOR","132KV 1 CAPACITOR 57MVAR/132KV","132KV 2 BUS","132KV 2 CAPACITOR","132KV CAP BANK 1","132KV CAP BANK 2","132KV CAP BANK 61","132KV CAP BANK 62","132kV 1 Xfmr T241","132kV 1 Xfmr T255","132kV 2 Bus H5","132kV A Bus","132kV Bus","132kV Bus Section 1","132kV ND 4MN1","132kV No1 Bus Section","132kV No2 Bus Section","132kV POC ND 41","132kV POC ND 42","15.75/275 KV TF 11","15.75/275 KV TF 12","15.75/275 KV TF 18","16/275 KV TF GEN1","16/275 KV TF GEN2","16/275 KV TF GEN3","16/275 KV TF GEN4","1A","1B","1GEN","1GTR","2 Bus","2 CAPACITOR (140MVAR/300KV)","2 CAPACITOR (40MVAR/132KV)","2 CAPACITOR (50MVAR/132kV)","2 CAPACITOR - 50MVAR/110KV","2 CAPACITOR 120MVAR","2 CAPACITOR 12MVAR/132KV","2 CAPACITOR 26MVAR/132KV","2 CAPACITOR 40MVAR/132KV","2 CAPACITOR 50MVAR/110KV","2 CAPACITOR 50MVAR/132KV","2 Capacitor","2 Gen Tfmr H27","2 Gen Tfmr H28","2 Gen Tfmr H30","2 Gen Tfmr H7","2 Gen Tfmr Mt S","2 Gen Transfmr H47","2 TRANSFORMER (288/138/19.1KV - 375MVA)","2 Transf t49","2 Transformer","2 Xfmr 132/11kV T200","220KV ND VBDP","220kV 7T1","220kV 7T2","220kV A Bus","220kV Bus No.1 Section","220kV ND 7T1","220kV ND 7TW1","220kV ND TR3","220kV POC ND 7TX1","220kV POC ND LBB2","220kV POC ND LBBT","220kV POC ND LCPS","220kV POC ND LKRE","220kV POC ND LRBE","220kV Shunt 1B","220kV Shunt 2B","220kV X7","220kV X8","275 KV REACTOR 1","275 KV REACTOR 2","275 KV SOUTH BUS REACTOR","275/132 KV TF 1","275/132 KV TF 2","275/15 KV TF 1","275/15 KV TF 2","275/15 KV TF 3","275KV 1 BUS","275KV 2 BUS","275KV 2 BUS 1 REACTOR (150MVAR/300KV)","275KV 2 BUS 1 REACTOR (60MVAR/300KV)","275KV 2 BUS REACTOR (100MVAR/300KV)","275KV 2 BUS REACTOR (150MVAR/300KV)","275KV 2 CAPACITOR","275KV BRINKWORTH REACTOR","275KV CAP BANK 61","275KV CAP BANK 62","275KV CAP BANK 64","275KV MOUNT GUNSON SOUTH REACTOR","275KV MOUNT LOCK REACTOR","275KV NORTH BUS REACTOR","275KV REACTOR 1","275KV REACTOR 2","275kV 1 Bus H20","275kV 1 Bus H29","275kV 1 Gen Transformer","275kV 1 Xfmr H86","275kV 2 Capacitor","275kV 3 Capacitor","275kV 3 Gen Transformer","275kV 4 Capacitor","275kV 4 Gen Transformer","275kV BELALIE REACTOR","275kV CAP BANK 1","275kV CAP BANK 61","275kV CAP BANK 62","275kV POC ND 8963","275kV POC ND 8B1","275kV POC ND 8MN1","275kV POC ND DRP","275kV POC ND DRP1","275kV POC ND DRP2","275kV POC ND HTF1","275kV POC ND TDRP","275kV WEST BUS REACTOR","275kV Xfmr BUS","2A","2B","2GEN","2GTR","2MN3","3 Bus","3 CAPACITOR (140MVAR/300KV)","3 CAPACITOR (50MVAR/110KV)","3 CAPACITOR - 120MVAR/275KV","3 CAPACITOR - 50MVAR/110KV","3 CAPACITOR 120MVAR/275KV","3 CAPACITOR 120MVAR/330KV","3 CAPACITOR 26MVAR/132KV","3 CAPACITOR 275KV","3 CAPACITOR 50MVAR/110KV","3 Capacitor 275kv","3 Gen Tfmr H27","3 Gen Tfmr t5","3 Gen Transfmr H47","3 Stat Comp H39","330KV 1 BUS","330KV BURONGA 1 REACTOR","330KV BURONGA 2 REACTOR","330KV EAST BUS REACTOR","330kV 1 Gen Transformer","330kV 2 Gen Transformer","330kV 3 Bus","330kV 5A NODE","330kV 5XF3 NODE","330kV A Bus","330kV A1 Bus","330kV B Bus","330kV Bus Section 2","330kV C Bus","330kV Feeder 8l React","330kV Feeder 8m React","330kV Feeder 9901 React","330kV Feeder 9902 React","330kV GEN Bus","330kV MAIN Bus","330kV POC ND 5XF1","330kV POC ND CA03","330kV POC ND L7Y","33kV Bus T140","3A","3B","3GTR","4 CAPACITOR (50MVAR 132KV)","4 CAPACITOR 120MVAR/275KV","4 CAPACITOR 120MVAR/330KV","4 CAPACITOR 275KV","4 CAPACITOR 50MVAR/110KV","4 CAPACITOR 50MVAR/132KV","4 Gen Tfmr H27","4 Gen Tfmr t5","4 STATIC COMPENSATOR -100 TO +350MVAR","4A","4B","4GTR","4MN1","5 CAPACITOR (120MVAR/275KV)","5 CAPACITOR - 200MVAR/275KV","5 CAPACITOR - 50MVAR/132KV","5 Gen Tfmr H7","500KV ND LBGS","500kV ND 6DRP.","500kV POC ND 6T2","500kV POC ND 6T2K","5A","5A 23/330kV Generator Transformer","5B","5B 23/330kV Generator Transformer","5_BANK_T152","6 CAPACITOR (120MVAR/275KV)","6 CAPACITOR (50MVAR/110KV)","6 CAPACITOR - 200MVAR/275KV","6 CAPACITOR 50MVAR/110KV","6 Capacitor","6 Gen Tfmr H7","66KV 3T1 NODE","66kV 3T1 NODE","66kV POC ND LMKS","6A 23/330kV Generator Transformer","6B 23/330kV Generator Transformer","7 CAPACITOR (50MVAR/110KV)","7 CAPACITOR 50MVAR/110KV","7 Gen Tfmr Roma","7SYN","8 CAPACITOR 120MVAR/275KV","8 CAPACITOR 50MVAR/110KV","8 Gen Tfmr Roma","820 Reactor 275kV","856 Reactor 275kV","857 GUYBAL MUNJAN 275KV FEEDER REACTOR","858 GUYBAL MUNJAN 275KV FEEDER REACTOR","877 TUMOULIN 275KV REACTOR","8847 FDR REACTOR 35MVAR","8857 STRATHMORE 275KV REACTOR","8858 STRATHMORE 275KV REACTOR","8902 WALKAMIN 275KV REACTOR","8905 ROSS TEE TULLY SOUTH 275KV REACTOR","8MN1","8MN2","8XF2","9 CAPACITOR 120MVAR/275KV","94K_Tee 132kV ND T94K","A1 Gen Transformer","A1 Trans","A1 Transformer","A2 Gen Transformer","A2 TRANS","A2 Trans","A2 Transformer","A2reac","A3 Gen Transformer","A3 Trans","A3reac","A4 Gen Trasnformer","A4 Trans","B1 Gen Transformer","B2 Gen Transformer","B3 Gen Transformer","BGEN","BU 110 kV C1 Capacitor Circuit","BUS1","Bungam_B 275kV POC ND 4MN1","CAP_2","CAP_41","CS 110 kV C1 Capacitor Circuit","CS 110 kV C2 Capacitor Circuit","CS 220 kV A Bus","Coorong2 SF 132kV POC ND 4X51","EAST BUS LEFT REACTOR 50MVar","Emeroo 132kV bus","Eraring 2A 330/23kV XFMR","F1 Trans","F2 Trans","FA 220 kV A Bus","G1","G11T","G12T","G2","GEN","GEN1 Transformer","GEN2 Transformer","GEN3 Transformer","GEN4 Transformer","GT 110 kV C1 Capacitor Circuit","GT 110 kV C3 Capacitor Bank Circuit","GT 220 kV C2 Capacitor Circuit","Gen Transformer","Goyder_WF 275 POC1 8XF1","H1 Trans","H2 Trans","H3","H78 ORANA 275KV 1 BUS","HALHIL","HF1","HTDP","HTF","HTFB","HWF","LAKE_BONNY1","LAKE_BONNY2A","LAKE_BONNY2B","LAKE_BONNY3","LCWW","LF 110 kV C1 Capacitor Circuit","LI 220 kV A Bus","LMAN","LMNE","LMPE","LMR1","LMR2","LMR3","LPLE","LQSF","LTGE","Lincoln Gap WF 1 275kV BUS","Lyps A No.1 Gen Trans","Lyps A No.2 Gen Trans","Lyps A No.3 Gen Trans","Lyps A No.4 Gen Trans","Lyps B No.1 Gen Trans","Lyps B No.2 Gen Trans","M1 Trans","M2 Trans","M3","MACWF No 2 Cap","MACWF No 5 Cap","MANNUM_B_GEN","MEWF 1 CAP","MEWF 2 CAP","MOURSF1","Mount Lock LHNW 275kV BUS","Mwtsn No.2","N0 1 Cap Bank 66kV","N0 4 Cap Bank 66kV","NBH_A","NBH_B","NN 110 kV A Bus","NN 110 kV C1 Capacitor Circuit","No 1 220kV Cap Bank *","No 1 22kV Cap Bank *","No 1 66kV Cap Bank","No 1 66kV Cap Bank *","No 1 Cap Bank","No 1 Cap Bank *","No 1 React 66kV *","No 1 Reactor *","No 1A Cap Bank","No 1b 66kV Cap Bank","No 1b Cap Bank","No 2 220kV Cap Bank","No 2 220kV Cap Bank *","No 2 22kV Cap Bank *","No 2 330kV Cap Bank","No 2 66kV Cap Bank","No 2 66kV Cap Bank *","No 2 Cap Bank","No 2 Cap Bank *","No 2 React 66kV *","No 2 Reactor *","No 2a 66kV Cap Bank","No 2b Cap Bank 66kV","No 3 220kV Cap Bank *","No 3 22kV Cap Bank *","No 3 Cap Bank","No 3 Capacitor Bank *","No 3 React 66kV *","No 3a 66kV Cap Bank","No 4 220kV Cap Bank","No 4 220kV Cap Bank *","No 4 Cap Bank *","No 4 Capacitor Bank *","No 4A Cap Bank *","No 4B Cap Bank","No 4b 66kV Cap Bank","No. 3A 66kV Capacitor Bank","No. 3B 66kV Capacitor Bank","No.1 220kV","No.1 330kV Gen Tx Group (Includes TG Bay)","No.1 Capacitor","No.1 Reactor","No.1 SVC","No.1 Static Var Compensator","No.1 Static Var Compersator","No.1 capacitor","No.1 reactor","No.1 static Var Compensator","No.1A 66kV Capacitor Bank","No.1B 66kV Capacitor Bank","No.2 330kV Gen Tx Group (Includes TG Bay)","No.2 330kV Gen Tx Group (Includes TG bay)","No.2 Capacitor","No.2 Reactor","No.2 SVC (Reactor)","No.2 capacitor","No.2 reactor","No.3 330kV Gen Tx Group (Includes TG Bay)","No.3 Capacitor","No.3 Reactor","No.3 capacitor","No.3 reactor","No.4 330kV Gen Tx Group (Includes TG Bay)","No.4 Capacitor","No.4 Capacitor A Bank","No.4 Capacitor B Bank","No.4 Reactor","No.4 capacitor","No.4 reactor","No.5 Capacitor","No.5 Reactor","No.5 capacitor","No.5 reactor","No.6 Capacitor","No.6 capacitor","No.6 reactor","No.7 Capacitor","No1 220","No1 220kV","No1 220kV Bus","No1 220kV Cap Bank","No1 220kV Reactor*","No1 330kV Cap Bank","No1 500kV","No1 66kV Cap Bank","No1 Cap Bank","No1 Csc","No1A 66kV Cap Bank","No1A Cap Bank","No1B 66kV Cap Bank","No1a 66kV Cap Bank","No2 220kV Reactor","No2 330kV Cap Bank","No2 66kV Cap Bank","No2 Cap Bank","No2 Csc","No2A 66kV Cap Bank","No2a Cap Bank","No2b 66kV Cap Bank","No3 220kV Cap Bank","No3 220kV Reactor","No3a Cap Bank","No3b 66kV Cap Bank","No4a 66kV Cap Bank","PM 220 kV A Bus","REACT_51","RI 110 kV C1 Capacitor Circuit","RI 110 kV C2 Capacitor Circuit","RI 110 kV C3 Capacitor Circuit","RI 110 kV C4 Capacitor Circuit","React 8810 H24","React 8811 H24","React Line 821 275kV","SH 110 kV C1 Capacitor Circuit","SH 220 kV A Bus","SUT_3","Shunt Reactor","Svc","T1_2","T3_4","T5","TEMPLE_B_GEN","T_1","T_P","UNIT 31 GENERATOR TRANSFORMER 275/15.7KV 31BAT01","UNIT 32 GENERATOR TRANSFORMER 275/15.7KV 32BAT01","UNIT 33 GENERATOR TRANSFORMER 275/15.7KV 33BAT01","Unit 1","Unit 2","Unit 3","Unit 4","Unit 5","Unit 6","Uralla 330kV POC ND 541","Uralla 330kV POC ND 542","WANDBG","WEST BUS LEFT REACTOR 50MVar","WF","WP_1","WW_1","WW_2","X1","X2","X3","X4","YDW 66kV Bus","Ywps No.1 Generator","Ywps No.2 Generator","Ywps No.3 Generator","Ywps No.4 Generator","x3"],"is_categorical":true},"DEVICE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"REACTOR\", \"CAPACITOR\", \"GEN\", \"SVC\", \"TRANS\", \"GRPGEN\", \"GENGRP\"])","mandatory":false,"comment":"One of REACTOR, CAPACITOR, GEN, SVC, TRANS or GRPGEN but may be extended to other types","examples":null,"enums":["REACTOR","CAPACITOR","GEN","SVC","TRANS","GRPGEN","GENGRP"]},"INSTRUCTION_SEQUENCE":{"sql_type":"NUMBER(4,0)","pl_type":"pl.UInt16","mandatory":false,"comment":"Order for execution of Instruction","examples":["0","1","3"],"is_integer":true,"unsigned_int":true,"num_int_bits":16},"INSTRUCTION_SUMMARY":{"sql_type":"VARCHAR2(400)","pl_type":"str","mandatory":false,"comment":"Verbose summary of instruction","examples":["Lower the voltage of 275KV 2 BUS at S5 Western Downs by 2.0 kV","Lower the voltage of 275kV POC ND 8MN1 Bus at H138 TARONG BESS by 2.0 kV","Lower the voltage of 275kV POC ND TDRP Bus at S3_Greenbank by 1.5 kV","NO INSTRUCTION"]},"PARTICIPANTID":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Categorical","mandatory":false,"comment":"The NEM id of the participant who owns the equipment","examples":["AEMO","AGL Barker Inlet","AGL Bayswater","AGL Hydro","AGL Loy Yang","AGL Macquarie","AGL SA Generation","AGL Sales Queensland","AusNet Services","Berrybank 2 Asset Pt","Berrybank Developmen","Brendale Battery Pro","Bulgana Wind Farm","Bungama Project (Sol","CS Energy Limited","CS SubCo Pty Ltd","CleanCo","Collector Windfarm P","Columboola Solar Far","Darlington Point Sol","Delta Electricity","Dundonnell WF","EE Solar 6 Pty Ltd","Ecogen Energy","Edenvale Solar Park","ElectraNet SA","Energy Australia","Energy Australia Yal","Ergon Energy Queensl","Glenellen Asset Pty","Goyder Wind Farm 1 P","Gunnedah Solar Farm","Hawkesdale Asset Pty","Hazelwood BESS Proje","IPM Australia Limite","Iberdrola Australia","Kiamal SF1","Latrobe Valley BESS","Limondale Belectric","Millmerran Energy","NEEDS_NOS_NAMES","NEEDS_PARTICIPANT_ID","NESF Pty Ltd As trus","NewGen Braemar","Origin E Osborne","Origin Energy","PARF Company 10 Pty","Pacific Hydro HAUGHT","Pelican Point Power","Powerlink Queensland","QGC","Ryan Corner Developm","Shell Energy Retail","Snowy Hydro","Stanwell Corporation","Stockyard Hill Wind","Sun Metals Corporati","Sunraysia Decmil Aus","Supernode Operations","TasNetworks","TransGrid","Ulinda Park ProjectC","Victorian Big Batter","Wandoan Solar Projec","Wellington Battery P","Wellington North Sol","Western Downs BESS P","Western Downs GPH","Woolooga Fund Pty Lt"],"is_categorical":true},"STATION_ID":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Categorical","mandatory":false,"comment":"The id of the station where the control equipment resides","examples":["94K_Tee","APD","ARARAT_TS","ARDROSSAN WEST 132/33kV SUBSTATION","ATS","Ararat WF","Armidale 330kV Substation","BATS","BETS","BGTS","BLTS","BLYTH WEST BESS","BTS","BUNDEY SUBSTATION","BURNIE","BWF","Balranald 220kV Substation","Bango Wind Farm 132kV Substation","Bannaby 500kV","Barker Inlet Power Station","Bayswater","Bayswater 500/330kV Switchyard","Beaconsfield 330kV Substation","Berrybank WF","Bogong PS","Bouldercombe 275kv","Braemar Power Station (H47)","Braemar Power Station 2 (H48)","Brendale BESS (T294)","Broken Hill 220kV Substation","Bungam_B","Buronga 220kV Switching Station","CBTS","CHAPEL STREET","CHERRY GARDENS SUBSTATION","CITY WEST SUBSTATION","CPTS","CROOKWELL 2 WF","CROWLANDS TS 220KV","Callide B Ps 275kV","Callide C Ps 275kV","Calvale 275kV","Canberra 330kV Substation","Capital Wind Farm 330kV","Capital Wind Farm 330kV.","Collector Windfarm 330kV","Colongra PS","Condamine Power Station (T200)","Coorong SF","Coorong2 SF","Crookwell 330kV Substation","Crudine Ridge Wind Farm 132kV Substation","Culcairn 330kV Switching Station","DARLING DOWNS POWER STATION","DAVENPORT 275kV SUBSTATION","DDTS","DRY CREEK 66/11kV POWER STATION + SWITCHYARD","DULACCA WIND FARM","Dapto 330kV Substation","Darlington Point 330kV Substation","Dartmouth PS","Deer Park 220kV Terminal Station","Dumaresq 330kV Switching Station","ELTS","ERARING BESS","ERTS","Eildon PS","Emeroo","Eraring 500/330kV Switchyard","Eraring PS 500kv","FARRELL","FBTS","GEORGE TOWN","GETS","GLADSTONE SOUTH 132KV NEW","GNTS","GOONDIWINDI NTH T296","GOYDER SOUTH WIND FARM","GTS","GUILDFORD SS","GWSF","Gladstone 132kV","Gladstone 275kV","Gladstone South 132kV","Glenrowan","Goyder_WF","Gullen Range 330kV Wind Farm","Gunnedah","H002 South Pine","H003 Belmont","H004 Mudgeeraba","H006 Gin Gin","H009 Palmwoods","H012 Mt. England","H013 Ross 275kV","H014 Middle Ridge","H015 Lilyvale","H016 Rocklea","H018 Tarong","H020 Broadsound","H021 Murarrie","H022 Loganlea","H031 Molendinar","H032 Chalumbin","H036 Blackwall 275kV","H038 Goodna","H039 Woree","H040 Wurdong","H060 WALKAMIN","H067 Calliope River","H077 Columboola","H085 Coopers Gap","H086 Darling Downs Solar Farm","H087 CRUSH CREEK","H091 HAUGHTON RIVER","H093 GUYBAL MUNJAN","H110 BROADSOUND ENERGY PARK","H113 ALDOGA SF","H138 TARONG BESS","H154 SUPERNODE BESS","H162 BANANA BRIDGE","H182 Swanbank BESS","H76 WANDOAN SOUTH","H78 ORANA","HALLWF1","HALLWF2","HAPPY VALLEY SUBSTATION 275/66kV","HGTS","HOTS","HTS","HUMMOCKS SUBSTATION","HWBESS","HYTS","Haymarket 330kV Substation","JLGSA","JLGSB","Jindera","KGTS","KINCRAIG 132/33kV SUBSTATION","KINGAROY 66KV","KOGAN CREEK PS","KTS","Kangaroo Valley Power Station","Kareeya Ps 132kV","Kemps Creek 500kV Substation","Kiamal 220kV Substation","Koorangie","LADBROKE GROVE POWER STN","LIAPOOTAH","LINDISFARNE","LY","LYPA","LYPB","Lake Bonney Wind Farm","Liddell 330kV Switchyard","Liddell Power Station","Lincoln Gap WF","Lismore 330kV Substation","Lower Tumut","Lower Tumut 330kV Switching Station","MACARTH","MANNUM SF2 (MANNUM ROAD)","MEWF","MLTS","MONASH SUBSTATION","MORTLAKE PS","MOURA SF","MWTS","Mason Park 132kV Switching Station eA","McKay Creek PS","Metz_SF","Mortlake Sth Windfarm","Mount Lock 275kV","Mount Piper 500/330kV Switchyard","Mount Stuart PS","Mount Stuart Ps","Munmorah 330kV Switchyard","Murra Warra","Murray","Murray 330kV Switching Station","Murraylink SA","Murraylink VIC","Muswellbrook 330kV Substation","NBHWF","NEEDS_STATION_ID","NEW NORFOLK","NPSD","Narrandera 132kV Substation","Nebo 275kV","Newcastle 330kV Substation","OCPL 1 + OCPL 2 GENERATION SYSTEM","Oakey Power Station","PALMERSTON","PARA 275/132/66kV SUBSTATION","PELICAN POINT GENERATOR SWITCHYARD","PINE LODGE 220KV","PLUMPTON 500kv","PORT LINCOLN 132KV","Port Augusta Energy Park","QUARANTINE PS","QUORN PARK 132kv","Queanbyn","R002 Braemar","R003 Bulli Creek","R004 Millmerran","R015 MISS","R5 Millmeran Ps","RCTS","RISDON","ROBERTSTOWN SUBSTATION","ROTS","ROTS_500","RTS","RWTS","Regentville 330kV Substation","Roma 132kV","Rookwood Road 330kV Substation","Rye Park Wind Farm South","S003 GREENBANK","S3_Greenbank","S5 Western Downs","SHEFFIELD","SHTS","SMTS","SNAPPER POINT DIESEL","SNUGGERY SUBSTATION","SOUTH EAST SUBSTATION","STUBBO SOLAR FARM","SVTS","Sapphire Windfarm 330kV Substation","Snowtown Nth and Sth","Stanwell 275kV","Strathmore 275kV","Supernode BESS (154)","Swanbank E Ps","Sydney East 330kV Substation","Sydney North 330kV Substation","Sydney South 330kV Substation","Sydney West 330kV Substation","T027 Moura","T030 Ashgrove West","T032 Blackwater","T035 Dysart","T050 Innisfail 132kV","T055 Turkinje","T056 Townsville South","T065 Alligator Creek 132kV","T067 Kemmis","T069 Newlands","T129 Edmonton","T136 Abermain","T141 Pioneer Valley","T155 West Darra","T161 Algester","T193 Clare South","T217 CONDABRI CENTRAL","T220 Collinsville North","T241 Lake Ross","T243 YARRANLEA NORTH","T255 Rugby Run Solar Farm","T271 Wandoan South Bess","TAILEM BEND SUBSTATION","TALLAWARRA","TBTS","TEMPLERS WEST SUBSTATION","TGTS","TORRENS A SWITCHYARD","TORRENS B SWITCHYARD","TRTS","TSTS","TTS","TUMOULIN 275KV","TUNGKILLO SUBSTATION","Tallawarra","Tamworth 330kV Substation","Tarong North Ps","Tarong Ps","Tarrone 500kV","Terang 220kv","Tomago 330kV Switching Station","Torrens Island BESS","Townsville Gt Ps","Townsville Zinc","Tuggerah 330kV Substation","Tyabb 220kv","URANQUINTY 132KV","Ulinda Park BESS","Upper Tumut","Upper Tumut 330kV Switching Station","Uralla","VBB","Vales Point 330kV Switchyard","Vales Point PS 330kV","Vineyard 330kV Substation","WAMBO WF","WAMBO WF2","WATERLOO WIND FARM","WATTLE POINT 132KV","WBTS","WILLOGOLECHE WIND FARM","WISF","WMTS","WOTS","Wagga 330kV Substation","Walla Walla 330kV Substation","Wandoan South (H76)","Wellington 330","Wellington 330kV Substation","Wellington North SF","West Kiewa PS","Western Downs BESS","Wivenhoe Ps","Wollar West 330kV Substation","Woolooga 275kV","YPS","Yass 330kV Substation","Yendon Wind Farm (YDW)"],"is_categorical":true},"TARGET":{"sql_type":"NUMBER(20,5)","pl_type":"pl.Float64","mandatory":false,"comment":"Instruction for the device, for this interval null denotes no instruction","examples":["-1.5","-2"],"is_float":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23VOLTAGE_INSTRUCTION%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":23370037,"decompressed_size_all_time":7168251170},"visibility":"Public","trigger":"Signal or instructions issued"},"VOLTAGE_INSTRUCTION_TRK":{"package":"VOLTAGE_INSTRUCTIONS","pdr_config":{"mappings":[{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"TRACK","VERSION":1},{"REPORT_NAME":"VOLTAGE_INSTRUCTION","REPORT_SUB_TYPE":"TRACK","VERSION":2}],"transaction_type":"INSERT"},"documentation_urls":["https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec75.htm#9"],"comment":"Parent record for Voltage Instructions (MVAr Dispatch). 'SIGNAL' records will have no children; 'INSTRUCTION' records will have children","primary_keys":["RUN_DATETIME","VERSION_DATETIME"],"indexes":[["RUN_DATETIME","VERSION_DATETIME"]],"columns":{"RUN_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"MVAr Interval - a timestamp of when instructions issued","examples":["2026/09/01 00:00:12"],"parse_csv_as_string":true,"is_s_datetime":true},"VERSION_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":true,"comment":"Datetime the file was published by VDS - Versions differ from Run_DateTime only for Supplemental runs","examples":["2026/09/01 00:00:12"],"parse_csv_as_string":true,"is_s_datetime":true},"EST_EXPIRY":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Estimated expiry time of current Instruction set","examples":["2026/09/01 00:25:12"],"parse_csv_as_string":true,"is_s_datetime":true},"EST_NEXT_INSTRUCTION":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"Estimated issue time of next Instruction set","examples":["2026/09/01 00:02:12"],"parse_csv_as_string":true,"is_s_datetime":true},"FILE_TYPE":{"sql_type":"VARCHAR2(20)","pl_type":"pl.Enum([\"SIGNAL\", \"INSTRUCTION\"])","mandatory":false,"comment":"Either 'SIGNAL' (childless) or 'INSTRUCTION'","examples":null,"enums":["SIGNAL","INSTRUCTION"]},"OPERATING_MODE":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Enum([\"AUTO\", \"AUTO-VERIFIED\", \"MANUAL\"])","mandatory":false,"comment":"The current VDS operating mode. Valid values: AUTO, AUTO-VERFIED, MANUAL","examples":null,"enums":["AUTO","AUTO-VERIFIED","MANUAL"]},"OPERATING_STATUS":{"sql_type":"VARCHAR2(100)","pl_type":"str","mandatory":false,"comment":"Unstructured code and message from AEMO","examples":["(1) VDS Active"]},"SE_DATETIME":{"sql_type":"DATE","pl_type":"pl.Datetime()","mandatory":false,"comment":"State Estimator start time, when a snapshot is taken of SCADA values","examples":["2026/09/01 00:10:12"],"parse_csv_as_string":true,"is_s_datetime":true},"SOLUTION_CATEGORY":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Enum([\"NONE [No flag set]\", \"SUCCESS [solution succeeded]\", \"WARNING [solution completed with warnings]\", \"FAILURE\"])","mandatory":false,"comment":"VDS solver solution category. Valid values: SUCCESS, WARNING, FAILURE","examples":null,"enums":["NONE [No flag set]","SUCCESS [solution succeeded]","WARNING [solution completed with warnings]","FAILURE"]},"SOLUTION_STATUS":{"sql_type":"VARCHAR2(60)","pl_type":"pl.Categorical","mandatory":false,"comment":"VDS solver solution status. Valid values: NOACTCNV [Solved with no instructions], NOVIOACT, CONVERGE, UNMANAGE, UNMANCTG, CTGDIV, SENHDIV [Failed with too many violations], BCDIV","examples":["CONVERGE [Solved with no violations]","CTGDIV [1 or more CTGs diverged]","NOACTCNV [Solved with no instructions]","NOVIOACT [Instructions with no violations]","UNMANCTG [Solved with CTG violations]"],"is_categorical":true}},"example_zip_url":"https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23VOLTAGE_INSTRUCTION_TRK%23FILE01%23202609010000.zip","manifest_summary":{"first_month":{"year":2024,"month":8},"last_month":{"year":2026,"month":9},"compressed_size_per_month":78263,"decompressed_size_all_time":23055460},"visibility":"Public","trigger":"Signal or instructions issued"}},"packages":{"CONFIGURATION":{"comment":"MMS Data Model Configuration Management and Control","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec3.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec0.png"},"table_names":["MMS_DATA_MODEL_AUDIT"]},"ANCILLARY_SERVICES":{"comment":"Ancillary Service Contract Data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec5.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec1.png"},"table_names":["CONTRACTAGC","CONTRACTLOADSHED","CONTRACTREACTIVEPOWER","CONTRACTRESTARTSERVICES","CONTRACTRESTARTUNITS"]},"ASOFFER":{"comment":"Offer data for Ancillary Service Contracts","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec7.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec2.png"},"table_names":["OFFERAGCDATA","OFFERASTRK","OFFERLSHEDDATA","OFFERRESTARTDATA","OFFERRPOWERDATA"]},"BIDS":{"comment":"Energy and Market Based FCAS Offers","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec9.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec3.png"},"table_names":["BIDDAYOFFER","BIDDAYOFFER_D","BIDOFFERFILETRK","BIDOFFERPERIOD","BIDPEROFFER_D","MNSP_BIDOFFERPERIOD","MNSP_DAYOFFER","MTPASA_OFFERDATA","MTPASA_OFFERFILETRK"]},"BILLING_CONFIG":{"comment":"Configuration data for the Billing Process","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec11.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec4.png"},"table_names":["BILLINGCALENDAR","GST_BAS_CLASS","GST_RATE","GST_TRANSACTION_CLASS","GST_TRANSACTION_TYPE","SECDEPOSIT_INTEREST_RATE","SECDEPOSIT_PROVISION"]},"BILLING_RUN":{"comment":"Results from a published Billing Run. The settlement data and billing run data are updated daily between 6am and 8am for AEMO's prudential processes. In a normal week, AEMO publishes one PRELIM, one FINAL and two REVISION runs in addition to the daily runs.Each billing run is uniquely identified by contract year, week no and bill run no.","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec13.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec5.png"},"table_names":["BILLING_APC_COMPENSATION","BILLING_APC_RECOVERY","BILLING_CASHSEC_INTEREST_PAY","BILLING_CO2E_PUBLICATION","BILLING_CO2E_PUBLICATION_TRK","BILLING_DAILY_ENERGY_SUMMARY","BILLING_DIR_FINAL_AMOUNT","BILLING_DIR_FINAL_RECOVERY","BILLING_DIR_PROV_AMOUNT","BILLING_DIR_PROV_RECOVERY","BILLING_DIR_RECOVERY_DETAIL","BILLING_DIRECTION_RECON_OTHER","BILLING_EFTSHORTFALL_AMOUNT","BILLING_EFTSHORTFALL_DETAIL","BILLING_ENERGY_GENSET_DETAIL","BILLING_ENERGY_TRAN_SAPS","BILLING_ENERGY_TRANSACTIONS","BILLING_FCAS_REG_AMT","BILLING_FCAS_REG_RESIDAMT","BILLING_FPP","BILLING_GST_DETAIL","BILLING_GST_SUMMARY","BILLING_IRSR_NSP_ALLOCATION","BILLING_NMAS_MANUAL_PAYMENT","BILLING_NMAS_MANUAL_RECOVERY","BILLING_NMAS_TST_PAYMENTS","BILLING_NMAS_TST_RECOVERY","BILLING_NMAS_TST_RECVRY_RBF","BILLING_NMAS_TST_RECVRY_TRK","BILLING_SECDEP_INTEREST_PAY","BILLING_SECDEP_INTEREST_RATE","BILLING_SECDEPOSIT_APPLICATION","BILLING_SUBST_DEMAND","BILLING_SUBST_RUN_VERSION","BILLING_WDR","BILLING_WDR_DETAIL","BILLINGAPCCOMPENSATION","BILLINGAPCRECOVERY","BILLINGASPAYMENTS","BILLINGASRECOVERY","BILLINGDAYTRK","BILLINGFEES","BILLINGFINANCIALADJUSTMENTS","BILLINGINTERRESIDUES","BILLINGINTRARESIDUES","BILLINGIRAUCSURPLUS","BILLINGIRAUCSURPLUSSUM","BILLINGIRFM","BILLINGIRNSPSURPLUS","BILLINGIRNSPSURPLUSSUM","BILLINGIRPARTSURPLUS","BILLINGIRPARTSURPLUSSUM","BILLINGPRIORADJUSTMENTS","BILLINGREALLOC","BILLINGREALLOC_DETAIL","BILLINGREGIONEXPORTS","BILLINGREGIONFIGURES","BILLINGREGIONIMPORTS","BILLINGRUNTRK","BILLRESERVETRADERPAYMENT","BILLRESERVETRADERRECOVERY","BILLWHITEHOLE"]},"DEMAND_FORECASTS":{"comment":"Regional Demand Forecasts and Intermittent Generation forecasts.","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec17.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec6.png"},"table_names":["DEMANDOPERATIONALACTUAL","DEMANDOPERATIONALFORECAST","INTERMITTENT_CLUSTER_AVAIL","INTERMITTENT_CLUSTER_AVAIL_DAY","INTERMITTENT_DS_PRED","INTERMITTENT_DS_RUN","INTERMITTENT_GEN_FCST","INTERMITTENT_GEN_FCST_DATA","INTERMITTENT_GEN_FCST_P5_PRED","INTERMITTENT_GEN_FCST_P5_RUN","INTERMITTENT_GEN_FCST_PRED","INTERMITTENT_GEN_FCST_RUN","INTERMITTENT_GEN_LIMIT","INTERMITTENT_GEN_LIMIT_DAY","INTERMITTENT_GEN_SCADA","INTERMITTENT_P5_PRED","INTERMITTENT_P5_RUN","MTPASA_INTERMITTENT_AVAIL","MTPASA_INTERMITTENT_LIMIT","PERDEMAND","RESDEMANDTRK","ROOFTOP_PV_ACTUAL","ROOFTOP_PV_ACTUAL_PRED","ROOFTOP_PV_ACTUAL_RUN","ROOFTOP_PV_FCST_P5_PRED","ROOFTOP_PV_FCST_P5_RUN","ROOFTOP_PV_FCST_PRED","ROOFTOP_PV_FCST_RUN","ROOFTOP_PV_FORECAST"]},"DISPATCH":{"comment":"Results from a published Dispatch Run","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec19.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec7.png"},"table_names":["CONSTRAINTRELAXATION_OCD","DISPATCH_AGC_DATA","DISPATCH_CONSTRAINT_FCAS_OCD","DISPATCH_FCAS_REQ_CONSTRAINT","DISPATCH_FCAS_REQ_RUN","DISPATCH_INTERCONNECTION","DISPATCH_LOCAL_PRICE","DISPATCH_MNSPBIDTRK","DISPATCH_MR_SCHEDULE_TRK","DISPATCH_PRICE_REVISION","DISPATCH_ROOFTOP_PV_FCST_TRK","DISPATCH_UNIT_CONFORMANCE","DISPATCH_UNIT_SCADA","DISPATCHBLOCKEDCONSTRAINT","DISPATCHCASESOLUTION","DISPATCHCONSTRAINT","DISPATCHINTERCONNECTORRES","DISPATCHLOAD","DISPATCHOFFERTRK","DISPATCHPRICE","DISPATCHREGIONSUM","INTERMITTENT_FORECAST_TRK","NEGATIVE_RESIDUE"]},"FORCE_MAJEURE":{"comment":"Market Suspensions and administer pricing event data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec24.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec8.png"},"table_names":["APEVENT","APEVENTREGION","IRFMAMOUNT","IRFMEVENTS","MARKET_SUSPEND_REGIME_SUM","MARKET_SUSPEND_REGION_SUM","MARKET_SUSPEND_SCHEDULE","MARKET_SUSPEND_SCHEDULE_TRK","OVERRIDERRP","REGIONAPC","REGIONAPCINTERVALS"]},"GD_INSTRUCT":{"comment":"General Dispatch Instruction data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec26.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec9.png"},"table_names":["GDINSTRUCT","INSTRUCTIONSUBTYPE","INSTRUCTIONTYPE"]},"GENERIC_CONSTRAINT":{"comment":"Generic Constraint Standing Data and Invocations","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec28.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec10.png"},"table_names":["EMSMASTER","GENCONDATA","GENCONSET","GENCONSETINVOKE","GENCONSETTRK","GENERICCONSTRAINTRHS","GENERICEQUATIONDESC","GENERICEQUATIONRHS","PASA_CONTINGENCY_DEFINITION","SPDCONNECTIONPOINTCONSTRAINT","SPDINTERCONNECTORCONSTRAINT","SPDREGIONCONSTRAINT"]},"IRAUCTION":{"comment":"Inter-regional Residue Auction data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec30.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec11.png"},"table_names":["AUCTION","AUCTION_CALENDAR","AUCTION_IC_ALLOCATIONS","AUCTION_REVENUE_ESTIMATE","AUCTION_REVENUE_TRACK","AUCTION_RP_ESTIMATE","AUCTION_TRANCHE","RESIDUE_BID_TRK","RESIDUE_CON_DATA","RESIDUE_CON_ESTIMATES_TRK","RESIDUE_CON_FUNDS","RESIDUE_CONTRACTS","RESIDUE_FUNDS_BID","RESIDUE_PRICE_BID","RESIDUE_PRICE_FUNDS_BID","RESIDUE_PUBLIC_DATA","RESIDUE_TRK","RESIDUECONTRACTPAYMENTS","RESIDUEFILETRK","SRA_CASH_SECURITY","SRA_FINANCIAL_AUC_MARDETAIL","SRA_FINANCIAL_AUC_MARGIN","SRA_FINANCIAL_AUC_RECEIPTS","SRA_FINANCIAL_AUCPAY_DETAIL","SRA_FINANCIAL_AUCPAY_SUM","SRA_FINANCIAL_RUNTRK","SRA_OFFER_PRODUCT","SRA_OFFER_PROFILE","SRA_PRUDENTIAL_CASH_SECURITY","SRA_PRUDENTIAL_COMP_POSITION","SRA_PRUDENTIAL_EXPOSURE","SRA_PRUDENTIAL_RUN","VALUATIONID"]},"MARKET_CONFIG":{"comment":"Standing data for the market","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec32.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec12.png"},"table_names":["AREA","BIDTYPES","BIDTYPESTRK","FCAS_REGU_USAGE_FACTORS","FCAS_REGU_USAGE_FACTORS_TRK","INTERCONNECTOR","INTERCONNECTORALLOC","INTERCONNECTORCONSTRAINT","INTRAREGIONALLOC","LOSSFACTORMODEL","LOSSMODEL","MARKET_PRICE_THRESHOLDS","REGION","REGION_AREA","REGIONSTANDINGDATA","TRANSMISSIONLOSSFACTOR"]},"MARKET_NOTICE":{"comment":"Market Notice data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec34.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec13.png"},"table_names":["MARKETNOTICEDATA","MARKETNOTICETYPE","PARTICIPANTNOTICETRK"]},"METER_DATA":{"comment":"Wholesale market aggregated Meter data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec36.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec14.png"},"table_names":["METERDATA_AGGREGATE_READS","METERDATA_INDIVIDUAL_READS","METERDATA_INTERCONNECTOR","METERDATA_SAPS","METERDATA_WDR_READS"]},"MTPASA":{"comment":"Results from a published Medium Term PASA Run and region-aggregate offered PASA Availability of scheduled generators","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec38.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec15.png"},"table_names":["MTPASA_CASERESULT","MTPASA_CONSTRAINTRESULT","MTPASA_CONSTRAINTSUMMARY","MTPASA_DUIDAVAILABILITY","MTPASA_INTERCONNECTORRESULT","MTPASA_LOLPRESULT","MTPASA_REGIONAVAIL_TRK","MTPASA_REGIONAVAILABILITY","MTPASA_REGIONITERATION","MTPASA_REGIONRESULT","MTPASA_REGIONSUMMARY"]},"P5MIN":{"comment":"Results from a published Five-Minute Predispatch Run","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec40.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec16.png"},"table_names":["P5MIN_BLOCKEDCONSTRAINT","P5MIN_CASESOLUTION","P5MIN_CONSTRAINTSOLUTION","P5MIN_FCAS_REQ_CONSTRAINT","P5MIN_FCAS_REQ_RUN","P5MIN_INTERCONNECTORSOLN","P5MIN_INTERMITTENT_FCST_TRK","P5MIN_INTERSENSITIVITIES","P5MIN_LOCAL_PRICE","P5MIN_PRICESENSITIVITIES","P5MIN_REGIONSOLUTION","P5MIN_ROOFTOP_PV_FCST_TRK","P5MIN_SCENARIODEMAND","P5MIN_SCENARIODEMANDTRK","P5MIN_UNITSOLUTION"]},"PARTICIPANT_REGISTRATION":{"comment":"Participant registration data","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec43.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec17.png"},"table_names":["ADG_DETAIL","AGGREGATE_DISPATCH_GROUP","BIDDUIDDETAILS","BIDDUIDDETAILSTRK","DISPATCHABLEUNIT","DUALLOC","DUDETAIL","DUDETAILSUMMARY","GENMETER","GENUNITS","GENUNITS_UNIT","MNSP_INTERCONNECTOR","MNSP_PARTICIPANT","PARTICIPANT","PARTICIPANTACCOUNT","PARTICIPANTCATEGORY","PARTICIPANTCATEGORYALLOC","PARTICIPANTCLASS","PARTICIPANTCREDITDETAIL","PASA_DUID_SUBSTATION_MAPPING","PASA_INTERCONNECTOR_BOUNDARY","PASA_INTERCONNECTOR_MAPPING","PASA_INTERZONAL_BOUNDARY","PASA_INTERZONAL_MAPPING","PASA_SUBSTATION_ZONE_MAPPING","PASA_ZONE_REGION_MAPPING","PMS_GROUP","PMS_GROUPNMI","PMS_GROUPSERVICE","STADUALLOC","STATION","STATIONOPERATINGSTATUS","STATIONOWNER","STATIONOWNERTRK"]},"PRE_DISPATCH":{"comment":"Results from a published Predispatch RunStorage optionsThere are 2 ways to define the Pre-dispatch table primary keys (PKs) to define which data is loaded to the database and which data is retained:Option 1 (default)Overwrite older records when they are succeeded by later versions for the same entity and period. This is the Data Model default and results in the consumption of far less storage. Data Model updates issued by AEMO target this configuration so participants implementing option 2a or 2b must maintain their changes when AEMO releases a new Data Model version.PredispatchLoad: DateTime, DUIDPredispatchInterconnectorRes: DateTime, InterconnectorID,PredispatchPrice: DateTime, RegionIDPredispatchPriceSensitivities: DateTime, RegionIDPredispatchInterSensitivities: InterconnectorID, DateTimePredispatchRegionsum: DateTime, RegionIDOption 2aRetain only the Pricing records for tables relating to Price data and Physical records for tables relating to Physical data (e.g. targets). Approximately 50 times more storage volumes than option 1.PredispatchLoad: PredispatchSeqNo, DateTime, DUIDPredispatchInterconnectorRes: PredispatchSeqNo, DateTime, InterconnectorID,PredispatchPrice: PredispatchSeqNo, DateTime, RegionIDPredispatchPriceSensitivities: PredispatchSeqNo, DateTime, RegionIDPredispatchInterSensitivities: PredispatchSeqNo, DateTime, InterconnectorIDPredispatchRegionsum: PredispatchSeqNo, DateTime, RegionIDOption 2bRetain both Physical and Pricing data for Intervention runs. If Intervention cases are stored in entirety, you must select the data carefully. The logic is the same as for Dispatch, i.e. Intervention Pricing is always where Intervention = 0 and Physical data is where Intervention = PredispatchCaseSolution.Intervention for the same PredispatchSeqNo.Doubles the storage of option 2a but ONLY for Intervened cases.PredispatchLoad: PredispatchSeqNo, Intervention, DateTime, DUIDPredispatchInterconnectorRes: PredispatchSeqNo, Intervention,DateTime, InterconnectorID,PredispatchPrice: PredispatchSeqNo, Intervention, DateTime, RegionIDPredispatchPriceSensitivities: PredispatchSeqNo, Intervention, DateTime, RegionIDPredispatchInterSensitivities: PredispatchSeqNo, Intervention, DateTime, InterconnectorIDPredispatchRegionsum: PredispatchSeqNo, Intervention, DateTime, RegionIDNotes:The data in the PredispatchIS file is always ordered so the pdrLoader writes the relevant data first and discards the subsequent irrelevant data, or writes the subsequent data, depending on how the PKs are defined.You may order the PKs in a different order, depending on your local requirements. Any decision to change the PK column composition or order must consider the functional and performance impacts to existing applications or queries.The pdrLoader caches PK definitions for performance reasons so any change to the PKs requires a restart of the application.The TRANSACTION_TYPE default in the PDR_REPORT_RECORDS management tables for PREDISPATCH* tables is UPDATE-INSERT. You can modify this to INSERT for Option 2b, as the attempt to first perform an update becomes redundant. This can improve load performance.","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec45.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec18.png"},"table_names":["PD_FCAS_REQ_CONSTRAINT","PD_FCAS_REQ_RUN","PD_INTERMITTENT_FCST_TRK","PD_ROOFTOP_PV_FCST_TRK","PREDISPATCH_LOCAL_PRICE","PREDISPATCH_MNSPBIDTRK","PREDISPATCHBLOCKEDCONSTRAINT","PREDISPATCHCASESOLUTION","PREDISPATCHCONSTRAINT","PREDISPATCHINTERCONNECTORRES","PREDISPATCHINTERSENSITIVITIES","PREDISPATCHLOAD","PREDISPATCHOFFERTRK","PREDISPATCHPRICE","PREDISPATCHPRICESENSITIVITIES","PREDISPATCHREGIONSUM","PREDISPATCHSCENARIODEMAND","PREDISPATCHSCENARIODEMANDTRK"]},"RESERVE_DATA":{"comment":"Energy and FCAS reserve requirements","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec51.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec19.png"},"table_names":["MTPASA_RESERVELIMIT","MTPASA_RESERVELIMIT_REGION","MTPASA_RESERVELIMIT_SET"]},"SETTLEMENT_CONFIG":{"comment":"Configuration and input data for the Settlements Process","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec53.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec20.png"},"table_names":["ANCILLARY_RECOVERY_SPLIT","MARKET_FEE_CAT_EXCL","MARKET_FEE_CAT_EXCL_TRK","MARKET_FEE_EXCLUSION","MARKET_FEE_EXCLUSIONTRK","MARKETFEE","MARKETFEEDATA","MARKETFEETRK","PARTICIPANT_BANDFEE_ALLOC","REALLOCATION","REALLOCATIONINTERVAL","SETCFG_PARTICIPANT_MPF","SETCFG_PARTICIPANT_MPFTRK","SETCFG_SAPS_SETT_PRICE","SETCFG_WDR_REIMBURSE_RATE","SETCFG_WDRRR_CALENDAR"]},"SETTLEMENT_DATA":{"comment":"Results from a published Settlements Run. The settlement data and billing run data are updated daily between 6am and 8am for AEMO's prudential processes. In a normal week, AEMO publishes one PRELIM, one FINAL and two REVISION runs in addition to the daily runs.","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec55.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec21.png"},"table_names":["DAYTRACK","SET_APC_COMPENSATION","SET_APC_RECOVERY","SET_ANCILLARY_SUMMARY","SET_ENERGY_GENSET_DETAIL","SET_ENERGY_REGION_SUMMARY","SET_ENERGY_TRAN_SAPS","SET_ENERGY_TRANSACTIONS","SET_FCAS_CLAWBACK_REQ","SET_FCAS_CLAWBACK_RUN_TRK","SET_FCAS_CLAWBACK_UNITSOLN","SET_FCAS_PAYMENT","SET_FCAS_RECOVERY","SET_FCAS_REG_AMOUNT","SET_FCAS_REG_DEF_AMT","SET_FCAS_REG_DEF_RESIDAMT","SET_FCAS_REG_RESIDAMT","SET_FCAS_REGULATION_TRK","SET_FPP","SET_IRSR_DIRECTIONAL_LINK","SET_IRSR_LOOP_NETTRADE_AMOUNT","SET_IRSR_LOOP_NSP_ALLOCATION","SET_IRSR_LOOP_REGION_SUMMARY","SET_NMAS_MANUAL_PAYMENT","SET_NMAS_RECOVERY","SET_NMAS_RECOVERY_RBF","SET_RECOVERY_ENERGY","SET_SUBST_RUN_VERSION","SET_SUBSTITUTE_DEMAND","SET_WDR_RECON_DETAIL","SET_WDR_TRANSACT","SETFCASREGIONRECOVERY","SETINTRAREGIONRESIDUES","SETIRAUCSURPLUS","SETIRNSPSURPLUS","SETIRPARTSURPLUS","SETIRSURPLUS","SETLOCALAREAENERGY","SETLOCALAREATNI","SETLSHEDPAYMENT","SETLSHEDRECOVERY","SETMARKETFEES","SETREALLOCATIONS","SETRESERVERECOVERY","SETRESTARTPAYMENT","SETRESTARTRECOVERY","SETRPOWERPAYMENT","SETRPOWERRECOVERY"]},"STPASA_SOLUTION":{"comment":"Results from a published Short Term PASA Run","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec58.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec22.png"},"table_names":["STPASA_CASESOLUTION","STPASA_CONSTRAINTSOLUTION","STPASA_DUIDAVAILABILITY","STPASA_FNM_CASESOLUTION","STPASA_FNM_CONSTRAINTSOLUTION","STPASA_FNM_DUIDAVAILABILITY","STPASA_FNM_INTERCONNECTORSOLN","STPASA_FNM_INTERZONALSOLUTION","STPASA_FNM_REGIONSOLUTION","STPASA_FNM_REGIONSUMMARY","STPASA_FNM_ZONESOLUTION","STPASA_FNM_ZONESUMMARY","STPASA_INTERCONNECTORSOLN","STPASA_REGIONSOLUTION"]},"TRADING_DATA":{"comment":"30 minute Trading interval results","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec60.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec23.png"},"table_names":["AVERAGEPRICE30","TRADINGINTERCONNECT","TRADINGPRICE"]},"HISTORICAL TABLES":{"comment":"These tables are no longer used","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec62.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec24.png"},"table_names":["APCCOMP","APCCOMPAMOUNT","APCCOMPAMOUNTTRK","BIDPEROFFER","BILLADJUSTMENTS","BILLING_CSP_DEROGATION_AMOUNT","BILLING_DIRECTION_RECONCILIATN","BILLING_MR_PAYMENT","BILLING_MR_RECOVERY","BILLING_MR_SHORTFALL","BILLING_MR_SUMMARY","BILLING_RES_TRADER_PAYMENT","BILLING_RES_TRADER_RECOVERY","BILLINGCPDATA","BILLINGCPSUM","BILLINGCUSTEXCESSGEN","BILLINGEXCESSGEN","BILLINGGENDATA","BILLINGINTERVENTION","BILLINGINTERVENTIONREGION","BILLINGRESERVERECOVERY","BILLINGRESERVEREGIONRECOVERY","BILLINGRESERVETRADER","BILLINGRESERVETRADERREGION","BILLINGSMELTERREDUCTION","BILLINTERVENTIONRECOVERY","BILLINTERVENTIONREGIONRECOVERY","BILLSMELTERRATE","CONNECTIONPOINT","CONNECTIONPOINTDETAILS","CONNECTIONPOINTOPERATINGSTA","CONTRACTGOVERNOR","CONTRACTRESERVEFLAG","CONTRACTRESERVETHRESHOLD","CONTRACTRESERVETRADER","CONTRACTUNITLOADING","CONTRACTUNITUNLOADING","DAYOFFER","DAYOFFER_D","DEFAULTDAYOFFER","DEFAULTOFFERTRK","DEFAULTPEROFFER","DELTAMW","DISPATCH_FCAS_REQ","DISPATCHBIDTRK","DISPATCHCASE_OCD","DISPATCHCASESOLUTION_BNC","DISPATCHLOAD_BNC","DISPATCHTRK","FORCEMAJEURE","FORCEMAJEUREREGION","GENUNITMTRINPERIOD","INTCONTRACT","INTCONTRACTAMOUNT","INTCONTRACTAMOUNTTRK","INTERCONNMWFLOW","MARKETSUSPENSION","MARKETSUSREGION","MAS_CP_CHANGE","MAS_CP_MASTER","METERDATA","METERDATA_GEN_DUID","METERDATA_TRK","METERDATATRK","MNSP_FILETRK","MNSP_OFFERTRK","MNSP_PEROFFER","MR_DAYOFFER_STACK","MR_EVENT","MR_EVENT_SCHEDULE","MR_PEROFFER_STACK","MTPASA_CASE_SET","MTPASA_CASESOLUTION","MTPASA_CONSTRAINTSOLUTION","MTPASA_INTERCONNECTORSOLUTION","MTPASA_REGIONSOLUTION","MTPASA_RESERVELIMITSOLUTION","MTPASACONSTRAINTSOLUTION_D","MTPASAINTERCONNECTORSOLUTION_D","MTPASAREGIONSOLUTION_D","OARTRACK","OFFERFILETRK","OFFERGOVDATA","OFFERULOADINGDATA","OFFERUNLOADINGDATA","P5MIN_FCAS_REQUIREMENT","PASACASESOLUTION","PASACONSTRAINTSOLUTION","PASAINTERCONNECTORSOLUTION","PASAREGIONSOLUTION","PEROFFER","PEROFFER_D","PREDISPATCH_FCAS_REQ","PREDISPATCHBIDTRK","REALLOCATIONDETAILS","REALLOCATIONINTERVALS","REALLOCATIONS","REGIONFCASRELAXATION_OCD","RESERVE","SET_CSP_DEROGATION_AMOUNT","SET_CSP_SUPPORTDATA_CONSTRAINT","SET_CSP_SUPPORTDATA_ENERGYDIFF","SET_CSP_SUPPORTDATA_SUBPRICE","SET_MR_PAYMENT","SET_MR_RECOVERY","SET_RUN_PARAMETER","SETAGCPAYMENT","SETAGCRECOVERY","SETAPCCOMPENSATION","SETAPCRECOVERY","SETCPDATA","SETCPDATAREGION","SETFCASCOMP","SETFCASRECOVERY","SETGENDATA","SETGENDATAREGION","SETGOVPAYMENT","SETGOVRECOVERY","SETINTERVENTION","SETINTERVENTIONRECOVERY","SETIRFMRECOVERY","SETLULOADPAYMENT","SETLULOADRECOVERY","SETLUNLOADPAYMENT","SETLUNLOADRECOVERY","SETRESERVETRADER","SETSMALLGENDATA","SETVICBOUNDARYENERGY","SETVICENERGYFIGURES","SETVICENERGYFLOW","STPASA_SYSTEMSOLUTION","STPASA_UNITSOLUTION","TRADINGLOAD","TRADINGREGIONSUM"]},"PDPASA":{"comment":"The PDPASA package provides a 30-minute solving process to the Market systemsThe current methodology for calculating reserves in the PreDispatch timeframe is determined in a post processing step using a heuristic calculation based the results and Interconnector limits from the PreDispatch run.The calculation is a reserve assessment based on the PASA solver similar to existing ST and MT PASA business processesThe process reflects all intra-regional and inter-regional network constraints as an input to the process","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec66.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec25.png"},"table_names":["PDPASA_CASESOLUTION","PDPASA_CONSTRAINTSOLUTION","PDPASA_DUIDAVAILABILITY","PDPASA_FNM_CASESOLUTION","PDPASA_FNM_CONSTRAINTSOLUTION","PDPASA_FNM_DUIDAVAILABILITY","PDPASA_FNM_INTERCONNECTORSOLN","PDPASA_FNM_INTERZONALSOLUTION","PDPASA_FNM_REGIONSOLUTION","PDPASA_FNM_REGIONSUMMARY","PDPASA_FNM_ZONESOLUTION","PDPASA_FNM_ZONESUMMARY","PDPASA_INTERCONNECTORSOLN","PDPASA_REGIONSOLUTION"]},"PRUDENTIALS":{"comment":"Prudential Management","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec68.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec26.png"},"table_names":["BANK_GUARANTEE","CASH_SECURITY","PRUDENTIALCOMPANYPOSITION","PRUDENTIALRUNTRK"]},"MCC_DISPATCH":{"comment":"Results from the Marginal Constraint Cost (MCC) re-run of the dispatch process. The MCC forms part of the part of the AER‟s “Electricity transmission network service providers Service target performance incentive Scheme”","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec70.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec27.png"},"table_names":["MCC_CASESOLUTION","MCC_CONSTRAINTSOLUTION"]},"NETWORK":{"comment":"Configuration data for the physical network","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec72.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec28.png"},"table_names":["NETWORK_EQUIPMENTDETAIL","NETWORK_OUTAGECONSTRAINTSET","NETWORK_OUTAGEDETAIL","NETWORK_OUTAGESTATUSCODE","NETWORK_RATING","NETWORK_REALTIMERATING","NETWORK_STATICRATING","NETWORK_SUBSTATIONDETAIL"]},"VOLTAGE_INSTRUCTIONS":{"comment":"Instructions for MVAr Dispatch","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec74.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec29.png"},"table_names":["VOLTAGE_INSTRUCTION","VOLTAGE_INSTRUCTION_TRK"]},"PD7DAY":{"comment":"Results from a published Predispatch 7 Day Run","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec76.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec30.png"},"table_names":["PD7DAY_CASESOLUTION","PD7DAY_CONSTRAINTSOLUTION","PD7DAY_INTERCONNECTORSOLUTION","PD7DAY_MARKET_SUMMARY","PD7DAY_PRICESOLUTION"]},"FPP":{"comment":"Results from a published Frequency Performance Payments (FPP) Run. The FPP calculation runs performs every trading interval (typically 5 minutes, but different for P5MIN / PREDISPATCH) and input data feeding into the calculations. The output data from the calculations is published on that same interval. There are some tables that operate on different frequencies (e.g. P5MIN / PREDISPATCH) as well as some data becoming public the following market day. For further details please see the FPP procedure and supporting documentation.","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec78.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec31.png"},"table_names":["FPP_CONSTRAINT_FREQ_MEASURE","FPP_CONTRIBUTION_FACTOR","FPP_EST_COST","FPP_EST_PERF_COST_RATE","FPP_EST_RESIDUAL_COST_RATE","FPP_FCAS_SUMMARY","FPP_FORECAST_DEFAULT_CF","FPP_FORECAST_RESIDUAL_DCF","FPP_HIST_PERFORMANCE","FPP_HIST_REGION_PERFORMANCE","FPP_P5_FWD_EST_COST","FPP_P5_FWD_EST_RESIDUALRATE","FPP_PD_FWD_EST_COST","FPP_PD_FWD_EST_RESIDUALRATE","FPP_PERFORMANCE","FPP_RCR","FPP_REGION_FREQ_MEASURE","FPP_RESIDUAL_CF","FPP_RESIDUAL_PERFORMANCE","FPP_RUN","FPP_UNIT_MW","FPP_USAGE"]},"SYSTEM_SECURITY_MANAGEMENT":{"comment":"Package for ISF (Improving Security Frameworks) for Electricity Power System Security procurement (not related to IT security)","doc_url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec80.htm#1","image":{"url":"https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec32.png"},"table_names":["SSM_CONTRACT_UNIT_AVAIL","SSM_ENABLEMENT_COSTS","SSM_ENABLEMENT_PERIOD","SSM_INDICATIVE_ROLL_DUID","SSM_INDICATIVE_ROLL_REGION","SSM_INSTRUCTION","SSM_SCHEDULE","SSM_SCHEDULED_AVAILABILITY"]}}}