# PREDISPATCHINTERSENSITIVITIES

> PREDISPATCHINTERSENSITIVITIES sets out the sensitivity flows for each interconnector by period.

## Column Schema

### DATETIME

> Period date and time

SQL Type: `DATE`
Polars Type: `pl.Datetime()`

This column is mandatory, and a primary key.

Example: `2024/07/01 00:30:00`

### INTERCONNECTORID

> Unique interconnector identifier

SQL Type: `VARCHAR2(10)`
Polars Type: `pl.Categorical`

This column is mandatory, and a primary key.

Examples:

- `N-Q-MNSP1`
- `NSW1-QLD1`
- `T-V-MNSP1`
- `V-S-MNSP1`
- `V-SA`
- `VIC1-NSW1`

### INTERVENTION

> Flag to indicate if this result set was sourced from the pricing run (INTERVENTION=0) or the physical run (INTERVENTION=1). In the event that there is not intervention in the market, both pricing and physical runs correspond to INTERVENTION=0

!!! danger "Warning"
    Unlike most tables with an INTERVENTION column, INTERVENTION is not a primary key of PREDISPATCHINTERSENSITIVITIES.

For more information, see the [dedicated documentation page](../../guide/querying.md#intervention).

SQL Type: `NUMBER(2,0)`
Polars Type: `pl.Boolean`

This column is not mandatory.

Example: `0`

### INTERVENTION_ACTIVE

> Flag to indicate if the sensitivity run contains an active intervention constraint: 0 = No, 1 = Yes

For more information, see the [dedicated documentation page](../../guide/querying.md#intervention).

SQL Type: `NUMBER(1,0)`
Polars Type: `pl.Boolean`

This column is not mandatory.

Example: `0`

### LASTCHANGED

> Last date and time record changed

For more information, see the [dedicated documentation page](../../guide/querying.md#deduplication).

SQL Type: `DATE`
Polars Type: `pl.Datetime()`

This column is not mandatory.

Example: `2024/07/01 00:05:05`

### MWFLOW1

> MW flow for given Interconnector for scenario 1

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW2

> MW flow for given Interconnector for scenario 2

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW3

> MW flow for given Interconnector for scenario 3

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `661`

### MWFLOW4

> MW flow for given Interconnector for scenario 4

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.16`, `0.06`, `0`, `600`

### MWFLOW5

> MW flow for given Interconnector for scenario 5

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.45`, `1.19`, `0`, `661`

### MWFLOW6

> MW flow for given Interconnector for scenario 6

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.30`, `0.23`, `0`, `600`

### MWFLOW7

> MW flow for given Interconnector for scenario 7

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.45`, `0.23`, `0`, `661`

### MWFLOW8

> MW flow for given Interconnector for scenario 8

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.71`, `0`, `520`

### MWFLOW9

> MW flow for given Interconnector for scenario 9

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW10

> MW flow for given Interconnector for scenario 10

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.90`, `0`, `500`

### MWFLOW11

> MW flow for given Interconnector for scenario 11

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `3.17`, `0`, `600`

### MWFLOW12

> MW flow for given Interconnector for scenario 12

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.45`, `0.08`, `0`, `247`

### MWFLOW13

> MW flow for given Interconnector for scenario 13

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-1.36`, `1.39`, `0`, `600`

### MWFLOW14

> MW flow for given Interconnector for scenario 14

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-1.69`, `1.83`, `0`, `335`

### MWFLOW15

> MW flow for given Interconnector for scenario 15

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `4.31`, `0`, `600`

### MWFLOW16

> MW flow for given Interconnector for scenario 16

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.84`, `0`, `600`

### MWFLOW17

> MW flow for given Interconnector for scenario 17

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.39`, `0`, `600`

### MWFLOW18

> MW flow for given Interconnector for scenario 18

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `5.34`, `0`, `520`

### MWFLOW19

> MW flow for given Interconnector for scenario 19

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.87`, `0`, `600`

### MWFLOW20

> MW flow for given Interconnector for scenario 20

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.03`, `0`, `520`

### MWFLOW21

> MW flow for given Interconnector for scenario 21

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Example: `0`

### MWFLOW22

> MW flow for given Interconnector for scenario 22

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Example: `0`

### MWFLOW23

> MW flow for given Interconnector for scenario 23

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Example: `0`

### MWFLOW24

> MW flow for given Interconnector for scenario 24

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Example: `0`

### MWFLOW25

> MW flow for given Interconnector for scenario 25

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.17`, `0`, `614`

### MWFLOW26

> MW flow for given Interconnector for scenario 26

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `4.25`, `0`, `600`

### MWFLOW27

> MW flow for given Interconnector for scenario 27

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.37`, `0.07`, `0`, `661`

### MWFLOW28

> MW flow for given Interconnector for scenario 28

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-2.46`, `1.31`, `0`, `600`

### MWFLOW29

> MW flow for given Interconnector for scenario 29

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.20`, `1.19`, `0`, `600`

### MWFLOW30

> MW flow for given Interconnector for scenario 30

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW31

> MW flow for given Interconnector for scenario 31

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `661`

### MWFLOW32

> MW flow for given Interconnector for scenario 32

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `2.20`, `0`, `600`

### MWFLOW33

> MW flow for given Interconnector for scenario 33

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.45`, `1.19`, `0`, `661`

### MWFLOW34

> MW flow for given Interconnector for scenario 34

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.23`, `3.17`, `0`, `600`

### MWFLOW35

> MW flow for given Interconnector for scenario 35

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.55`, `0.18`, `0`, `567`

### MWFLOW36

> MW flow for given Interconnector for scenario 36

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW37

> MW flow for given Interconnector for scenario 37

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.11`, `1.19`, `0`, `600`

### MWFLOW38

> MW flow for given Interconnector for scenario 38

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW39

> MW flow for given Interconnector for scenario 39

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW40

> MW flow for given Interconnector for scenario 40

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW41

> MW flow for given Interconnector for scenario 41

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW42

> MW flow for given Interconnector for scenario 42

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `1.19`, `0`, `600`

### MWFLOW43

> MW flow for given Interconnector for scenario 43

SQL Type: `NUMBER(15,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-0.68`, `0.08`, `0`, `600`

### PERIODID

> PERIODID is just a period count, starting from 1 for each predispatch run. Use DATETIME to determine half hour period.

SQL Type: `VARCHAR2(20)`
Polars Type: `str`

This column is not mandatory.

Example: `1`

### PREDISPATCHSEQNO

> Unique identifier of predispatch run in the form YYYYMMDDPP with 01 at 04:30

SQL Type: `VARCHAR2(20)`
Polars Type: `str`

This column is not mandatory.

Examples:

- `2024063041`
- `2024070601`

### RUNNO

> LP Solver Predispatch run no, typically 1. It increments if the case is re-run.

SQL Type: `NUMBER(3,0)`
Polars Type: `pl.UInt16`

This column is not mandatory.

Example: `1`

## New Data Timing

> Every 5 minutes

## Code Examples

### Polars

Explicitly listing every column, casting to enums, categoricals etc is not essential, but may speed up parsing.
Swapping `int` for `pl.UInt16`, `pl.Int32` would also speed up parsing. However some of the datatypes are inferred, so they may be wrong.

This code deduplicates for you.
Deduplication is normally only required across multiple months.

This code assumes that all columns are present, which may not be true for older files.

```python
import polars as pl
import polars.selectors as cs

# e.g. "2029/03/15 00:05:00"
dt_s_fmt = "%Y/%m/%d %H:%M:%S"

csv_paths = ["SOMEFILE.CSV", "OTHERFILE.CSV"]

lf = (
    pl.concat(
        [
            pl.scan_csv(
                csv_path,  # must be unzipped beforehand
                skip_rows=1,  # skip the header
                infer_schema=False,  # much faster
            )
            .filter(cs.by_index(0) == "D")  # drop the footer
            .select(~cs.by_index(range(4)))  # drop metadata columns
            for csv_path in csv_paths
        ],
        how="diagonal_relaxed",
    )
    .with_columns(
        pl.col("DATETIME", "LASTCHANGED").str.strptime(pl.Datetime, dt_s_fmt),
    )
    # Polars can't cast string straight to bool. Need to go via something else.
    .cast({"INTERVENTION": pl.UInt8, "INTERVENTION_ACTIVE": pl.UInt8})
    .cast(
        {
            "INTERCONNECTORID": pl.Categorical,
            "INTERVENTION": pl.Boolean,
            "INTERVENTION_ACTIVE": pl.Boolean,
            "MWFLOW1": pl.Float64,
            "MWFLOW2": pl.Float64,
            "MWFLOW3": pl.Float64,
            "MWFLOW4": pl.Float64,
            "MWFLOW5": pl.Float64,
            "MWFLOW6": pl.Float64,
            "MWFLOW7": pl.Float64,
            "MWFLOW8": pl.Float64,
            "MWFLOW9": pl.Float64,
            "MWFLOW10": pl.Float64,
            "MWFLOW11": pl.Float64,
            "MWFLOW12": pl.Float64,
            "MWFLOW13": pl.Float64,
            "MWFLOW14": pl.Float64,
            "MWFLOW15": pl.Float64,
            "MWFLOW16": pl.Float64,
            "MWFLOW17": pl.Float64,
            "MWFLOW18": pl.Float64,
            "MWFLOW19": pl.Float64,
            "MWFLOW20": pl.Float64,
            "MWFLOW21": pl.Float64,
            "MWFLOW22": pl.Float64,
            "MWFLOW23": pl.Float64,
            "MWFLOW24": pl.Float64,
            "MWFLOW25": pl.Float64,
            "MWFLOW26": pl.Float64,
            "MWFLOW27": pl.Float64,
            "MWFLOW28": pl.Float64,
            "MWFLOW29": pl.Float64,
            "MWFLOW30": pl.Float64,
            "MWFLOW31": pl.Float64,
            "MWFLOW32": pl.Float64,
            "MWFLOW33": pl.Float64,
            "MWFLOW34": pl.Float64,
            "MWFLOW35": pl.Float64,
            "MWFLOW36": pl.Float64,
            "MWFLOW37": pl.Float64,
            "MWFLOW38": pl.Float64,
            "MWFLOW39": pl.Float64,
            "MWFLOW40": pl.Float64,
            "MWFLOW41": pl.Float64,
            "MWFLOW42": pl.Float64,
            "MWFLOW43": pl.Float64,
            "PERIODID": str,
            "PREDISPATCHSEQNO": str,
            "RUNNO": int,  # or pl.UInt16
        }
    )
    # Deduplicate
    # We want one row per ['DATETIME', 'INTERCONNECTORID']
    # Tie-breaker: greatest value of ['LASTCHANGED']
    .sort(["LASTCHANGED"], descending=False)
    .unique(subset=["DATETIME", "INTERCONNECTORID"], keep="last")
)

```

### Nemosis

This table is not yet available in [Nemosis](https://github.com/UNSW-CEEM/NEMOSIS/#static_table).

## Example File

From [PUBLIC_DVD_PREDISPATCHINTERCONNECTR_SENS_D_202407010000.zip](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2024/MMSDM_2024_07/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_DVD_PREDISPATCHINTERCONNECTR_SENS_D_202407010000.zip)

=== "Raw Text with Metadata"
    ```csv
    C,SETP.WORLD,DVD_PREDISPATCHINTERCONNECTR_SENS_D,AEMO,PUBLIC,2024/08/06,20:15:03,0000000428654011,,0000000428653863
    I,PREDISPATCH,INTERCONNECTR_SENS,1,PREDISPATCHSEQNO,RUNNO,INTERCONNECTORID,PERIODID,INTERVENTION,DATETIME,INTERVENTION_ACTIVE,MWFLOW1,MWFLOW2,MWFLOW3,MWFLOW4,MWFLOW5,MWFLOW6,MWFLOW7,MWFLOW8,MWFLOW9,MWFLOW10,MWFLOW11,MWFLOW12,MWFLOW13,MWFLOW14,MWFLOW15,MWFLOW16,MWFLOW17,MWFLOW18,MWFLOW19,MWFLOW20,MWFLOW21,MWFLOW22,MWFLOW23,MWFLOW24,MWFLOW25,MWFLOW26,MWFLOW27,MWFLOW28,MWFLOW29,MWFLOW30,MWFLOW31,MWFLOW32,MWFLOW33,MWFLOW34,MWFLOW35,MWFLOW36,MWFLOW37,MWFLOW38,MWFLOW39,MWFLOW40,MWFLOW41,MWFLOW42,MWFLOW43,LASTCHANGED
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070306,1,T-V-MNSP1,1,0,"2024/07/03 07:00:00",0,-136.14,-228.91,-65.94,-330.34,3.65,-448.26,87.65,-130.44,-221.15,-73.20,-316.92,3.65,-478,87.65,-184.98,-192.70,-160.44,-217.79,-75.65,-308.23,0,0,0,0,3.65,-478,8.93,-478,-143,-228.87,-63.73,-328.49,3.65,-448.26,87.65,-208.26,-142.70,-208.26,-123.53,-231.55,-123.53,-374.15,-18.35,"2024/07/03 06:34:09"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070306,1,V-S-MNSP1,1,0,"2024/07/03 07:00:00",0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,"2024/07/03 06:34:09"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070306,1,V-SA,1,0,"2024/07/03 07:00:00",0,-70,-49.32,-98.83,-49.32,-128.37,-49.32,-197.32,-70,-49.32,-98.83,-49.32,-137.73,-49.32,-255.09,-25,-98.83,0.39,-148.17,100.36,-246.29,0,0,0,0,-65.99,-98.83,-98.83,-70,-66.22,-49.32,-98.83,-49.32,-98.83,-49.32,-197.32,-49.32,-49.32,-49.32,-49.32,-73.84,-49.32,-98.83,302.61,"2024/07/03 06:34:09"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070306,1,VIC1-NSW1,1,0,"2024/07/03 07:00:00",0,393.14,280.70,488.99,176.78,750.40,-46.65,928.46,301.53,385.85,287.90,385.85,277.54,412.58,16.32,301.53,364.37,301.53,385.85,287.90,385.85,0,0,0,0,596.78,82.24,536.59,-2.46,382.77,280.75,491.12,178.71,723.02,-46.65,910.27,301.53,366.93,301.53,385.85,301.53,385.85,277.54,277.54,"2024/07/03 06:34:09"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,N-Q-MNSP1,1,0,"2024/07/03 07:30:00",0,-17,-17,-17,-17,-17,-17,-17,-17,-17,-17,-17,-17,-17,-9,-17,-17,-17,-17,-17,-17,0,0,0,0,-17,-25,-17,-17,-17,-25,-17,-25,-9,-105,9,-17,-17,-17,-17,-17,-17,-17,-17,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,NSW1-QLD1,1,0,"2024/07/03 07:30:00",0,-612.44,-612.44,-612.44,-612.44,-612.44,-521.69,-690.50,-612.44,-612.44,-612.44,-612.44,-612.44,-612.44,-377.99,-612.44,-612.44,-612.44,-612.44,-612.44,-612.44,0,0,0,0,-561,-702,-494.61,-688.46,-561,-702,-494.61,-798.96,-214.14,-857.72,235.21,-612.44,-612.44,-612.44,-612.44,-612.44,-612.44,-612.44,-612.44,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,T-V-MNSP1,1,0,"2024/07/03 07:30:00",0,-81.55,-81.55,-81.55,-81.55,-81.55,-221,-47.55,-81.55,-81.55,-62.55,-82.55,-40.55,-260,35.88,-81.55,-81.55,-81.55,-81.55,-62.55,-81.55,0,0,0,0,-81.55,-221,-47.55,-344.01,-81.55,-81.55,-81.55,-81.55,-81.55,-160.60,-61.72,-129.64,-33.46,-162.56,-1.37,-184.82,0,-364.63,-40.55,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,V-S-MNSP1,1,0,"2024/07/03 07:30:00",0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,V-SA,1,0,"2024/07/03 07:30:00",0,-6.97,-6.97,-6.97,-6.97,-6.97,34.79,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,71.09,-94.36,42.95,-56.69,93.05,-106.23,193.84,-145,0,0,0,0,42.95,21.54,93.05,54.95,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,-6.97,500.98,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070307,1,VIC1-NSW1,1,0,"2024/07/03 07:30:00",0,178.13,178.13,178.13,178.13,178.13,-3.98,241.96,79.29,276.39,-1.10,373.12,-229.70,412.35,-513.21,129.04,226.51,79.25,274.21,-3.52,311.18,0,0,0,0,29.92,108.42,-44,-51.77,178.13,178.13,178.13,178.13,178.13,98.97,197.73,130.16,225.49,97,256.76,74.38,258.10,-62.95,-254.03,"2024/07/03 07:04:15"
    D,PREDISPATCH,INTERCONNECTR_SENS,1,2024070308,1,N-Q-MNSP1,1,0,"2024/07/03 08:00:00",0,-25,-25,-25,-25,-25,-25,-73,-25,-25,-25,-25,-25,-25,-25,-25,-25,-25,-25,-25,-25,0,0,0,0,-25,-33,-25,-81,-25,-33,-17,-81,-9,-149.56,0,-25,-25,-25,-25,-25,-25,-25,-25,"2024/07/03 07:33:49"
    ...
    C,"END OF REPORT",1003
    ```

## Availability

This table is in the public monthly [MMSDM archive](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/).

I have collated the list of all those files for this table into one place, in [this CSV metadata file](../../manifests/per_table/csv/PREDISPATCHINTERSENSITIVITIES.csv). (Columns `year`, `month`, `url`, `compressed_size` in bytes).

    

The earliest available data is month 1 of 2015.
The most recent available data is month 7 of 2024.Every month in between has a file. (No gaps.)

## Data Size

    

Each year of data is approximately
6 MB when zipped,
63 MB as unzipped CSV.

        

    

## Deduplication and PDR Loader Configuration

The primary keys are:

- [`DATETIME`](#datetime)

- [`INTERCONNECTORID`](#interconnectorid)

The transaction type is ["UPDATE-INSERT"](https://di-help.docs.public.aemo.com.au/Content/pdrLoader/How_it_works.htm?TocPath=pdrLoader%7CAbout+pdrLoader%7C_____5#UPDATEINSERT), which means that you will likely see duplicate data with different values.

You should deduplicate by sorting based on `LASTCHANGED`, within each group of primary keys.

[PDR Loader configuration](https://nemweb.com.au/Reports/Current/MMSDataModelReport/PDRCONFIG/PROD_PUBLIC_PDR_CONFIG_FULL.zip) is:

| Report Name | Report Subtype | Version |
|---------------|-------------------|-----------|
| PREDISPATCH | INTERCONNECTR_SENS  | 1 |

This means that the CSV files start with metadata columns:

```csv
I,PREDISPATCH,INTERCONNECTR_SENS,1,...
D,PREDISPATCH,INTERCONNECTR_SENS,1,...
```

`ROW_FILTER_TYPE` is LASTCHANGED

## Indexes

- [`LASTCHANGED`](#lastchanged)

## Links

[This page as JSON](../json/tables/PREDISPATCHINTERSENSITIVITIES/bespoke.json) (schema documented [here](https://gitlab.com/MatthewDavis/mms-schema/-/blob/master/schema.py?ref_type=heads), but may change)

Download a [JSON Schema](../json/tables/PREDISPATCHINTERSENSITIVITIES/json-schema.json) specification for this table.

Official AEMO  schema documentation (multi-page):

- [page 1](https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46.htm#79)

- [page 2](https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec46_1.htm)

## Other Information

Package: [PRE_DISPATCH](../packages/PRE_DISPATCH.md)