# VOLTAGE_INSTRUCTION

> Child record for Voltage Instructions (MVAr Dispatch)

## Column Schema

### EMS_ID

> The unique identifier for reference within AEMO –matches equipment names between NOS and EMS

SQL Type: `VARCHAR2(60)`
Polars Type: `pl.Categorical`

This column is mandatory, and a primary key.

Examples:

- `APD.REAC.A2REAC.VSWT`
- `APD.REAC.A3REAC.VSWT`
- `ARDN_W.CAP.CAP1.VSWT`
- `ARMIDALE.CAP.C1.VSWT`
- `ARMIDALE.CAP.C2.VSWT`
- `ARMIDALE.CAP.C3.VSWT`
- `ARMIDALE.CAP.C4.VSWT`
- `ARMIDALE.CAP.C5.VSWT`
- `ARMIDALE.CAP.C6.VSWT`
- `ARMIDALE.REAC.R1.VSWT`

### RUN_DATETIME

> MVAr Interval – a timestamp of when instructions issued

SQL Type: `DATE`
Polars Type: `pl.Datetime()`

This column is mandatory, and a primary key.

Example: `2026/09/01 00:15:45`

### VERSION_DATETIME

> Datetime the file was published by VDS - Versions differ from Run_DateTime only for Supplemental runs

SQL Type: `DATE`
Polars Type: `pl.Datetime()`

This column is mandatory, and a primary key.

Example: `2026/09/01 00:15:45`

### ADDITIONAL_NOTES

> Additional information pertaining to a particular instruction, e.g. Previously issued instruction revoked

SQL Type: `VARCHAR2(60)`
Polars Type: `str`

This column is not mandatory.

Example: `1_Primary`

### CONFORMING

> [0,1] Denotes if the Device is currently conforming

SQL Type: `NUMBER(1,0)`
Polars Type: `pl.Int8`

This column is not mandatory.

Example: `1`

### CONTROL_TYPE

> One of VOLTAGE, TAP, MVAR, SWITCH or COMMIT but may be extended to other types

The SQL type is `VARCHAR2(20)`.
This is actually a factor/enum, with values:

- `VOLTAGE`

- `TAP`

- `MVAR`

- `SWITCH`

- `COMMIT`

This column is not mandatory.

### DEVICE_ID

> The company/participant preferred name of an equipment

SQL Type: `VARCHAR2(60)`
Polars Type: `pl.Categorical`

This column is not mandatory.

Examples:

- `1`
- `1 BUS 5 REACTOR`
- `8945`
- `1 BUS REACTOR 275KV`
- `1 BUS REACTOR 275KV H35 STRATHMORE`
- `1 Bus`
- `1 Bus Reactor (84Mvar/275kV)`
- `1 CAPACITOR (140MVAR/300KV)`
- `1 CAPACITOR (20MVAR/132KV)`
- `1 CAPACITOR (30 MVAR/132KV)`

### DEVICE_TYPE

> One of REACTOR, CAPACITOR, GEN, SVC, TRANS or GRPGEN but may be extended to other types

The SQL type is `VARCHAR2(20)`.
This is actually a factor/enum, with values:

- `REACTOR`

- `CAPACITOR`

- `GEN`

- `SVC`

- `TRANS`

- `GRPGEN`

- `GENGRP`

This column is not mandatory.

### INSTRUCTION_SEQUENCE

> Order for execution of Instruction

SQL Type: `NUMBER(4,0)`
Polars Type: `pl.UInt16`

This column is not mandatory.

Examples:
`0`, `1`, `3`

### INSTRUCTION_SUMMARY

> Verbose summary of instruction

SQL Type: `VARCHAR2(400)`
Polars Type: `str`

This column is not mandatory.

Examples:

- `Lower the voltage of 275KV 2 BUS at S5 Western Downs by 2.0 kV`
- `Lower the voltage of 275kV POC ND 8MN1 Bus at H138 TARONG BESS by 2.0 kV`
- `Lower the voltage of 275kV POC ND TDRP Bus at S3_Greenbank by 1.5 kV`
- `NO INSTRUCTION`

### PARTICIPANTID

> The NEM id of the participant who owns the equipment

For more information, see the [dedicated documentation page](../../guide/querying.md#duid-genset-id-etc).

SQL Type: `VARCHAR2(20)`
Polars Type: `pl.Categorical`

This column is not mandatory.

Examples:

- `AEMO`
- `AGL Barker Inlet`
- `AGL Bayswater`
- `AGL Hydro`
- `AGL Loy Yang`
- `AGL Macquarie`
- `AGL SA Generation`
- `AGL Sales Queensland`
- `AusNet Services`
- `Berrybank 2 Asset Pt`

### STATION_ID

> The id of the station where the control equipment resides

SQL Type: `VARCHAR2(60)`
Polars Type: `pl.Categorical`

This column is not mandatory.

Examples:

- `94K_Tee`
- `APD`
- `ARARAT_TS`
- `ARDROSSAN WEST 132/33kV SUBSTATION`
- `ATS`
- `Ararat WF`
- `Armidale 330kV Substation`
- `BATS`
- `BETS`
- `BGTS`

### TARGET

> Instruction for the device, for this interval null denotes no instruction

SQL Type: `NUMBER(20,5)`
Polars Type: `pl.Float64`

This column is not mandatory.

Examples:
`-1.5`, `-2`

## New Data Timing

> Signal or instructions issued

## Code Examples

### Polars

Explicitly listing every column, casting to enums, categoricals etc is not essential, but may speed up parsing.
Swapping `int` for `pl.UInt16`, `pl.Int32` would also speed up parsing. However some of the datatypes are inferred, so they may be wrong.

This code deduplicates for you.
Deduplication is normally only required across multiple months.

This code assumes that all columns are present, which may not be true for older files.

```python
import polars as pl
import polars.selectors as cs

# e.g. "2029/03/15 00:05:00"
dt_s_fmt = "%Y/%m/%d %H:%M:%S"

csv_paths = ["SOMEFILE.CSV", "OTHERFILE.CSV"]

lf = (
    pl.concat(
        [
            pl.scan_csv(
                csv_path,  # must be unzipped beforehand
                skip_rows=1,  # skip the header
                infer_schema=False,  # much faster
            )
            .filter(cs.by_index(0) == "D")  # drop the footer
            .select(~cs.by_index(range(4)))  # drop metadata columns
            for csv_path in csv_paths
        ],
        how="diagonal_relaxed",
    )
    .with_columns(
        pl.col("RUN_DATETIME", "VERSION_DATETIME").str.strptime(pl.Datetime, dt_s_fmt),
    )
    .cast(
        {
            "EMS_ID": pl.Categorical,
            "ADDITIONAL_NOTES": str,
            "CONFORMING": int,  # or pl.Int8
            "CONTROL_TYPE": pl.Enum(["VOLTAGE", "TAP", "MVAR", "SWITCH", "COMMIT"]),
            "DEVICE_ID": pl.Categorical,
            "DEVICE_TYPE": pl.Enum(
                ["REACTOR", "CAPACITOR", "GEN", "SVC", "TRANS", "GRPGEN", "GENGRP"]
            ),
            "INSTRUCTION_SEQUENCE": int,  # or pl.UInt16
            "INSTRUCTION_SUMMARY": str,
            "PARTICIPANTID": pl.Categorical,
            "STATION_ID": pl.Categorical,
            "TARGET": pl.Float64,
        }
    )
    # Deduplicate
    # We want one row per ['EMS_ID', 'RUN_DATETIME', 'VERSION_DATETIME']
    # Tie-breaker: greatest value of ['RUN_DATETIME', 'VERSION_DATETIME', 'EMS_ID']
    .sort(["RUN_DATETIME", "VERSION_DATETIME", "EMS_ID"], descending=False)
    .unique(subset=["EMS_ID", "RUN_DATETIME", "VERSION_DATETIME"], keep="last")
)

```

### Nemosis

This table is not yet available in [Nemosis](https://github.com/UNSW-CEEM/NEMOSIS/#static_table).

## Example File

From [PUBLIC_ARCHIVE_VOLTAGE_INSTRUCTION_FILE01_202609010000.zip](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/2026/MMSDM_2026_09/MMSDM_Historical_Data_SQLLoader/DATA/PUBLIC_ARCHIVE%23VOLTAGE_INSTRUCTION%23FILE01%23202609010000.zip)

=== "Raw Text with Metadata"
    ```csv
    C,SETP.WORLD,DVD_VOLTAGE_INSTRUCTION,AEMO,PUBLIC,2026/10/09,16:36:24,001791527784944,MONTHLY_ARCHIVE,001791527784944
    I,VOLTAGE_INSTRUCTION,INSTRUCTION,2,RUN_DATETIME,EMS_ID,PARTICIPANTID,STATION_ID,DEVICE_ID,DEVICE_TYPE,CONTROL_TYPE,TARGET,CONFORMING,INSTRUCTION_SUMMARY,VERSION_DATETIME,INSTRUCTION_SEQUENCE,ADDITIONAL_NOTES
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",APD.REAC.A2REAC.VSWT,AEMO,APD,A2reac,REACTOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",APD.REAC.A3REAC.VSWT,AEMO,APD,A3reac,REACTOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARDN_W.CAP.CAP1.VSWT,"ElectraNet SA","ARDROSSAN WEST 132/33kV SUBSTATION","132KV CAP BANK 1",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C1.VSWT,TransGrid,"Armidale 330kV Substation","No.1 capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C2.VSWT,TransGrid,"Armidale 330kV Substation","No.2 capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C3.VSWT,TransGrid,"Armidale 330kV Substation","No.3 Capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C4.VSWT,TransGrid,"Armidale 330kV Substation","No.4 Capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C5.VSWT,TransGrid,"Armidale 330kV Substation","No.5 Capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.CAP.C6.VSWT,TransGrid,"Armidale 330kV Substation","No.6 Capacitor",CAPACITOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.REAC.R1.VSWT,TransGrid,"Armidale 330kV Substation","No.1 reactor",REACTOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,"2026/09/01 00:15:45",ARMIDALE.REAC.R2.VSWT,TransGrid,"Armidale 330kV Substation","No.2 reactor",REACTOR,SWITCH,,1,"NO INSTRUCTION","2026/09/01 00:15:45",0,
    ...
    C,"END OF REPORT",1003
    ```

## Availability

Visibility: Public

This table is in the public monthly [MMSDM archive](https://www.nemweb.com.au/Data_Archive/Wholesale_Electricity/MMSDM/).

I have collated the list of all those files into one place, in [this CSV metadata file](../../manifests/per_table/csv/VOLTAGE_INSTRUCTION.csv). (Columns `year`, `month`, `url`, `compressed_size` in bytes).

The earliest available data is month 8 of 2024.
The most recent available data is month 9 of 2026.

 Every month in between has a file. (No gaps.)

## Data Size

Each year of data is approximately
280 MB when zipped,
3 GB as unzipped CSV.

## Deduplication and PDR Loader Configuration

The primary keys are:

- [`EMS_ID`](#ems_id)

- [`RUN_DATETIME`](#run_datetime)

- [`VERSION_DATETIME`](#version_datetime)

The transaction type is ["insert"](https://di-help.docs.public.aemo.com.au/Content/pdrLoader/How_it_works.htm?TocPath=pdrLoader%7CAbout+pdrLoader%7C_____5#INSERT), which means that you will usually not see duplicate data.
If you do, you can deduplicate based on the primary keys, without sorting first.
Rows from different files with the same primary keys should have the same values.

[PDR Loader configuration](https://nemweb.com.au/Reports/Current/MMSDataModelReport/PDRCONFIG/PROD_PUBLIC_PDR_CONFIG_FULL.zip) is:

| Report Name | Report Subtype | Version |
|---------------|-------------------|-----------|
| VOLTAGE_INSTRUCTION | INSTRUCTION  | 1 |
| VOLTAGE_INSTRUCTION | INSTRUCTION  | 2 |

This means that the CSV files start with metadata columns:

```csv
I,VOLTAGE_INSTRUCTION,INSTRUCTION,1,...
D,VOLTAGE_INSTRUCTION,INSTRUCTION,1,...
```

or

```csv
I,VOLTAGE_INSTRUCTION,INSTRUCTION,2,...
D,VOLTAGE_INSTRUCTION,INSTRUCTION,2,...
```

## Indexes

- [`RUN_DATETIME`](#run_datetime)

- [`VERSION_DATETIME`](#version_datetime)

- [`EMS_ID`](#ems_id)

## Links

[This page as JSON](../json/tables/VOLTAGE_INSTRUCTION/bespoke.json) (schema documented [here](https://gitlab.com/MatthewDavis/mms-schema/-/blob/master/schema.py?ref_type=heads), but may change)

Download a [JSON Schema](../json/tables/VOLTAGE_INSTRUCTION/json-schema.json) specification for this table.

[Official AEMO schema documentation](https://nemweb.com.au/Reports/Current/MMSDataModelReport/Electricity/ElectricityDataModelReport_files/Elec75.htm#1)

## Other Information

Package: [VOLTAGE_INSTRUCTIONS](../packages/VOLTAGE_INSTRUCTIONS.md)