Skip to content

NETWORK_EQUIPMENTDETAIL

NETWORK_EQUIPMENTDETAIL Provides details on equipment that may have outages or ratings. A single piece of equipment may have multiple records if its details change. A line will typically have at least two valid records at a time, once for each end of the line.

Column Schema

ELEMENTID

Equipment element id

SQL Type: NUMBER(15,0) Polars Type: pl.Int64

This column is mandatory, and a primary key.

Examples: 3, 3111

EQUIPMENTID

A unique identifier for this type of equipment at this substation

SQL Type: VARCHAR(30) Polars Type: str

This column is mandatory, and a primary key.

Examples:

  • 1
  • 110KV_714
  • 7217
  • 110KV_717
  • 110KV_721
  • 110KV_722
  • 110KV_731
  • 110KV_732
  • 110KV_733
  • 110KV_734

EQUIPMENTTYPE

The type of equipment. Valid values are: LINE = Line TRANS = Transformer CB = Circuit breaker ISOL = Isolator CAP = Capacitor REAC = Reactor UNIT = Unit

SQL Type: VARCHAR(10) Polars Type: pl.Categorical

This column is mandatory, and a primary key.

Examples:

  • BUS
  • CAP
  • LINE
  • N/A
  • REAC
  • SVC
  • TRANS

SUBSTATIONID

ID uniquely identifying the substation this equipment is located at

SQL Type: VARCHAR(30) Polars Type: str

This column is mandatory, and a primary key.

Examples:

  • ABC_B
  • AC
  • AL
  • ALDING
  • APD
  • ATS
  • BATS
  • BDSS
  • BETS
  • BLTS

VALIDFROM

The date that this record is applies from (inclusive)

SQL Type: TIMESTAMP(3) Polars Type: pl.Datetime()

This column is mandatory, and a primary key.

Example: 2003/04/28 16:51:08.000

Unlike most datetime columns, this one includes a millisecond component. e.g. 2029/03/15 00:00:00.123.

DESCRIPTION

A short description for this equipment.

SQL Type: VARCHAR(100) Polars Type: str

This column is not mandatory.

Examples:

  • Abermain 2 100/33kV XFMR
  • Abermain 3 100/33kV XFMR
  • Abermain 3 110kV BUS
  • Alan Shrff 11kV BUS
  • Alc/prtlnd 1 220kV BUS
  • Alc/prtlnd 2 500kV BUS
  • Alc/prtlnd 2 500kV REACT
  • Alc/prtlnd 3 500kV BUS
  • Alc/prtlnd 33kV BUS
  • Alc/prtlnd A2 33kV REACT

LASTCHANGED

The time that this record was last changed.

For more information, see the dedicated documentation page.

SQL Type: TIMESTAMP(3) Polars Type: pl.Datetime()

This column is not mandatory.

Example: 2000/01/01 00:00:10.000

Unlike most datetime columns, this one includes a millisecond component. e.g. 2029/03/15 00:00:00.123.

VALIDTO

The date that this record applies until (exclusive)

SQL Type: TIMESTAMP(3) Polars Type: pl.Datetime()

This column is not mandatory.

Example: 2003/06/04 14:57:33.000

Unlike most datetime columns, this one includes a millisecond component. e.g. 2029/03/15 00:00:00.123.

VOLTAGE

The voltage in KV for this equipment. Transformers may have multiple voltages defined. E.g. 132_110_33

SQL Type: VARCHAR(20) Polars Type: str

This column is not mandatory.

Examples:

  • 6.6
  • 11
  • 138.6_11.6
  • 288_138_19.1
  • 288_138_19

New Data Timing

When equipment details are added or changed

Code Examples

Polars

Casting is enums, categoricals etc is not essential, but may speed up parsing. Swapping int for pl.UInt16, pl.Int32 would also speed up parsing. However some of the datatypes are inferred, so they may be wrong.

This code deduplicates for you. Deduplication is normally only required across multiple months.

This code assumes that all columns are present, which may not be true for older files.

import polars as pl
import polars.selectors as cs

# for "TIMESTAMP" columns
# Note that Polars uses slightly different format strings for fractional seconds to `dt.strptime`
# e.g. "2029/03/15 00:00:00.123".
dt_ms_fmt = "%Y/%m/%d %H:%M:%S%.3f"

csv_paths = ["SOMEFILE.CSV", "OTHERFILE.CSV"]

lf = (
    pl.concat(
        [
            pl.scan_csv(
                csv_path,  # must be unzipped beforehand
                skip_rows=1,  # skip the header
                infer_schema=False,  # much faster
            )
            .filter(cs.by_index(0) == "D")  # drop the footer
            .select(~cs.by_index(range(4)))  # drop metadata columns
            for csv_path in csv_paths
        ],
        how="diagonal_relaxed",
    )
    .with_columns(
        pl.col("VALIDFROM", "LASTCHANGED", "VALIDTO").str.strptime(
            pl.Datetime, dt_ms_fmt
        ),
    )
    .cast(
        {
            "ELEMENTID": int,  # or pl.Int64
            "EQUIPMENTID": str,
            "EQUIPMENTTYPE": pl.Categorical,
            "SUBSTATIONID": str,
            "DESCRIPTION": str,
            "VOLTAGE": str,
        }
    )
    # Deduplicate
    # We want one row per ['ELEMENTID', 'EQUIPMENTID', 'EQUIPMENTTYPE', 'SUBSTATIONID', 'VALIDFROM']
    # Tie-breaker: greatest value of ['LASTCHANGED']
    .sort(["LASTCHANGED"], descending=False)
    .unique(
        subset=[
            "ELEMENTID",
            "EQUIPMENTID",
            "EQUIPMENTTYPE",
            "SUBSTATIONID",
            "VALIDFROM",
        ],
        keep="last",
    )
)

Nemosis

This table is not yet available in Nemosis.

Example File

From PUBLIC_ARCHIVE_NETWORK_EQUIPMENTDETAIL_FILE01_202609010000.zip

SUBSTATIONIDEQUIPMENTTYPEEQUIPMENTIDVALIDFROMVALIDTOVOLTAGEDESCRIPTIONLASTCHANGEDELEMENTID
SYTSBUS6MN12003/04/28 16:54:02.0009999/12/31 00:00:00.000500Sydenham 1 500kV BUS2003/04/28 16:54:12.0002024
TSTSBUS3MN42003/04/28 16:54:02.0009999/12/31 00:00:00.00066Templestow 4 66kV BUS2003/04/28 16:54:12.0002031
TTSBUS7MN12003/04/28 16:54:02.0009999/12/31 00:00:00.000220Thomastown 1 220kV BUS2003/04/28 16:54:12.0002036
TTSBUS3MN42003/04/28 16:54:02.0009999/12/31 00:00:00.00066Thomastown 4 66kV BUS2003/04/28 16:54:12.0002043
WOTSBUS3MN12003/04/28 16:54:03.0009999/12/31 00:00:00.00066Wodonga 1 66kV BUS2003/04/28 16:54:13.0002068
BETSCAP3BCAP_662003/04/28 16:54:15.0002024/07/01 15:06:56.51866Bendigo 3B 66kV CAP2024/07/01 15:07:06.5182080
BTSCAP1CAP_222003/04/28 16:54:15.0009999/12/31 00:00:00.00022Brunswick 1 22kV CAP2003/04/28 16:54:25.0002082
DDTSCAP2CAP_3302003/04/28 16:54:15.0009999/12/31 00:00:00.000330Dederang 2 330kV CAP2003/04/28 16:54:25.0002086
LYCAP1CAP2003/04/28 16:54:15.0009999/12/31 00:00:00.00066Loy Yang 1 66kV CAP2003/04/28 16:54:25.0002103
MLRCCAPZ122003/04/28 16:54:15.0009999/12/31 00:00:00.000165Mrrylnk Vc Z 12 165kV CAP2003/04/28 16:54:25.0002106
RTSCAP1CAP_1B_662003/04/28 16:54:15.0009999/12/31 00:00:00.00066Richmond 1 66kV CAP2003/04/28 16:54:25.0002113
...

CSETP.WORLDDVD_NETWORK_EQUIPMENTDETAILAEMOPUBLIC2026/10/0915:56:05001791525365583MONTHLY_ARCHIVE001791525365583
INETWORKEQUIPMENTDETAIL2SUBSTATIONIDEQUIPMENTTYPEEQUIPMENTIDVALIDFROMVALIDTOVOLTAGEDESCRIPTIONLASTCHANGEDELEMENTID
DNETWORKEQUIPMENTDETAIL2SYTSBUS6MN12003/04/28 16:54:02.0009999/12/31 00:00:00.000500Sydenham 1 500kV BUS2003/04/28 16:54:12.0002024
DNETWORKEQUIPMENTDETAIL2TSTSBUS3MN42003/04/28 16:54:02.0009999/12/31 00:00:00.00066Templestow 4 66kV BUS2003/04/28 16:54:12.0002031
DNETWORKEQUIPMENTDETAIL2TTSBUS7MN12003/04/28 16:54:02.0009999/12/31 00:00:00.000220Thomastown 1 220kV BUS2003/04/28 16:54:12.0002036
DNETWORKEQUIPMENTDETAIL2TTSBUS3MN42003/04/28 16:54:02.0009999/12/31 00:00:00.00066Thomastown 4 66kV BUS2003/04/28 16:54:12.0002043
DNETWORKEQUIPMENTDETAIL2WOTSBUS3MN12003/04/28 16:54:03.0009999/12/31 00:00:00.00066Wodonga 1 66kV BUS2003/04/28 16:54:13.0002068
DNETWORKEQUIPMENTDETAIL2BETSCAP3BCAP_662003/04/28 16:54:15.0002024/07/01 15:06:56.51866Bendigo 3B 66kV CAP2024/07/01 15:07:06.5182080
DNETWORKEQUIPMENTDETAIL2BTSCAP1CAP_222003/04/28 16:54:15.0009999/12/31 00:00:00.00022Brunswick 1 22kV CAP2003/04/28 16:54:25.0002082
DNETWORKEQUIPMENTDETAIL2DDTSCAP2CAP_3302003/04/28 16:54:15.0009999/12/31 00:00:00.000330Dederang 2 330kV CAP2003/04/28 16:54:25.0002086
DNETWORKEQUIPMENTDETAIL2LYCAP1CAP2003/04/28 16:54:15.0009999/12/31 00:00:00.00066Loy Yang 1 66kV CAP2003/04/28 16:54:25.0002103
DNETWORKEQUIPMENTDETAIL2MLRCCAPZ122003/04/28 16:54:15.0009999/12/31 00:00:00.000165Mrrylnk Vc Z 12 165kV CAP2003/04/28 16:54:25.0002106
DNETWORKEQUIPMENTDETAIL2RTSCAP1CAP_1B_662003/04/28 16:54:15.0009999/12/31 00:00:00.00066Richmond 1 66kV CAP2003/04/28 16:54:25.0002113
...
CEND OF REPORT1003

SUBSTATIONID,EQUIPMENTTYPE,EQUIPMENTID,VALIDFROM,VALIDTO,VOLTAGE,DESCRIPTION,LASTCHANGED,ELEMENTID
SYTS,BUS,6MN1,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",500,"Sydenham 1 500kV BUS","2003/04/28 16:54:12.000",2024
TSTS,BUS,3MN4,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",66,"Templestow 4 66kV BUS","2003/04/28 16:54:12.000",2031
TTS,BUS,7MN1,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",220,"Thomastown 1 220kV BUS","2003/04/28 16:54:12.000",2036
TTS,BUS,3MN4,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",66,"Thomastown 4 66kV BUS","2003/04/28 16:54:12.000",2043
WOTS,BUS,3MN1,"2003/04/28 16:54:03.000","9999/12/31 00:00:00.000",66,"Wodonga 1 66kV BUS","2003/04/28 16:54:13.000",2068
BETS,CAP,3BCAP_66,"2003/04/28 16:54:15.000","2024/07/01 15:06:56.518",66,"Bendigo 3B 66kV CAP","2024/07/01 15:07:06.518",2080
BTS,CAP,1CAP_22,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",22,"Brunswick 1 22kV CAP","2003/04/28 16:54:25.000",2082
DDTS,CAP,2CAP_330,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",330,"Dederang 2 330kV CAP","2003/04/28 16:54:25.000",2086
LY,CAP,1CAP,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",66,"Loy Yang 1 66kV CAP","2003/04/28 16:54:25.000",2103
MLRC,CAP,Z12,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",165,"Mrrylnk Vc Z 12 165kV CAP","2003/04/28 16:54:25.000",2106
RTS,CAP,1CAP_1B_66,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",66,"Richmond 1 66kV CAP","2003/04/28 16:54:25.000",2113
...
C,SETP.WORLD,DVD_NETWORK_EQUIPMENTDETAIL,AEMO,PUBLIC,2026/10/09,15:56:05,001791525365583,MONTHLY_ARCHIVE,001791525365583
I,NETWORK,EQUIPMENTDETAIL,2,SUBSTATIONID,EQUIPMENTTYPE,EQUIPMENTID,VALIDFROM,VALIDTO,VOLTAGE,DESCRIPTION,LASTCHANGED,ELEMENTID
D,NETWORK,EQUIPMENTDETAIL,2,SYTS,BUS,6MN1,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",500,"Sydenham 1 500kV BUS","2003/04/28 16:54:12.000",2024
D,NETWORK,EQUIPMENTDETAIL,2,TSTS,BUS,3MN4,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",66,"Templestow 4 66kV BUS","2003/04/28 16:54:12.000",2031
D,NETWORK,EQUIPMENTDETAIL,2,TTS,BUS,7MN1,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",220,"Thomastown 1 220kV BUS","2003/04/28 16:54:12.000",2036
D,NETWORK,EQUIPMENTDETAIL,2,TTS,BUS,3MN4,"2003/04/28 16:54:02.000","9999/12/31 00:00:00.000",66,"Thomastown 4 66kV BUS","2003/04/28 16:54:12.000",2043
D,NETWORK,EQUIPMENTDETAIL,2,WOTS,BUS,3MN1,"2003/04/28 16:54:03.000","9999/12/31 00:00:00.000",66,"Wodonga 1 66kV BUS","2003/04/28 16:54:13.000",2068
D,NETWORK,EQUIPMENTDETAIL,2,BETS,CAP,3BCAP_66,"2003/04/28 16:54:15.000","2024/07/01 15:06:56.518",66,"Bendigo 3B 66kV CAP","2024/07/01 15:07:06.518",2080
D,NETWORK,EQUIPMENTDETAIL,2,BTS,CAP,1CAP_22,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",22,"Brunswick 1 22kV CAP","2003/04/28 16:54:25.000",2082
D,NETWORK,EQUIPMENTDETAIL,2,DDTS,CAP,2CAP_330,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",330,"Dederang 2 330kV CAP","2003/04/28 16:54:25.000",2086
D,NETWORK,EQUIPMENTDETAIL,2,LY,CAP,1CAP,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",66,"Loy Yang 1 66kV CAP","2003/04/28 16:54:25.000",2103
D,NETWORK,EQUIPMENTDETAIL,2,MLRC,CAP,Z12,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",165,"Mrrylnk Vc Z 12 165kV CAP","2003/04/28 16:54:25.000",2106
D,NETWORK,EQUIPMENTDETAIL,2,RTS,CAP,1CAP_1B_66,"2003/04/28 16:54:15.000","9999/12/31 00:00:00.000",66,"Richmond 1 66kV CAP","2003/04/28 16:54:25.000",2113
...
C,"END OF REPORT",1003

Availability

Visibility: Public

This table is in the public monthly MMSDM archive.

I have collated the list of all those files into one place, in this CSV metadata file. (Columns year, month, url, compressed_size in bytes).

The earliest available data is month 8 of 2024. The most recent available data is month 9 of 2026.

Every month in between has a file. (No gaps.)

Data Size

Each year of data is approximately 9 MB when zipped, 86 MB as unzipped CSV.

Deduplication and PDR Loader Configuration

The primary keys are:

The transaction type is "INSERT-UPDATE", which means that you will likely see duplicate data with different values.

You should deduplicate by sorting based on LASTCHANGED, within each group of primary keys.

PDR Loader configuration is:

Report Name Report Subtype Version
NETWORK EQUIPMENTDETAIL 1
NETWORK EQUIPMENTDETAIL 2

This means that the CSV files start with metadata columns:

I,NETWORK,EQUIPMENTDETAIL,1,...
D,NETWORK,EQUIPMENTDETAIL,1,...

or

I,NETWORK,EQUIPMENTDETAIL,2,...
D,NETWORK,EQUIPMENTDETAIL,2,...

ROW_FILTER_TYPE is LASTCHANGED

Indexes

This page as JSON (schema documented here, but may change)

Download a JSON Schema specification for this table.

Official AEMO schema documentation

Other Information

Package: NETWORK